ELC-15-2402 Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-243943 Permit Number: ELC-9-15-2402
Scheduled Inspection Date: September 25, 2015 Permit Type: Electrical - Commercial
Inspector: Devaney, Michael
Inspection Type: Final
Owner: , BARRY UNIVERSITY Work Classification: Addition/Alteration
Job Address: 11300 NE 2 Avenue Browne Hall
Miami Shores, FL 33138-0000
Phone Number
Parcel Number 1121360010160-14
Project: BARRY UNIVERSITY
Contractor: CHI ALARMS, INC. Phone: (305)827-2856
Building Department Comments
FIRE ALARM SENSOR REPLACEMENT Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed
Failed
Correction ❑
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
September 24, 2015 For Inspections please call: (305)762-4949 Page 14 of 34
4,( � Y
a\
Miami Shores Village yEtO
10050 N.E.2nd Avenue NE � � �� �
Miami Shores,FL 33138-0000 `
OR Phone:
Phone: (305)795 2204 N
Expiration: 03122/2016
Project Address Parcel Number Applicant
11300 NE 2 Avenue Number: Browne Hall 1121360010160-14
Miami Shores, FL 33138-0000 Block: Lot: BARRY UNIVERSITY INC
Owner Information Address Phone Cell
BARRY UNIVERSITY INC 11300 NE 2 Avenue
MIAMI SHORES FL 33161-6628
11300 NE 2 Avenue
MIAMI SHORES FL 33161-6628
Contractor(s) Phone Cell Phone Valuation: $ 2,500.00
CHI ALARMS, INC. (305)827-2856
Total Sq Feet: 0
Type of Work:FIRE ALARM SENSOR REPLACEMENT Available Inspections:
Additional Info:FIRE ALARM SENSOR REPLACEMENT Inspection Type:
Classification:Commercial
Final
Scanning:3 Meter Box
Alteration
Relocation
Fire Alarm
Service Change
Review Electrical
Underground
W.W.
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
CCF $1.80
DBPR Fee Invoice# ELC-9-15-57162
$2.25 09/22/2015 Credit Card $50.00 $ 112.30
DCA Fee $2.25
Education Surcharge $0.60 09/24/2015 Credit Card $ 112.30 $0.00
Permit Fee $150.00
Scanning Fee $3.00
Technology Fee $2.40
Total: $162.30
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accu[ at all work will be done in compliance with all applicable laws regulating
construction and zoning. Futhermore, I authorize the above-named coat r do the work stated.
September 24, 2015
Authorized Signature:Owner / Applicant / Co / Agent Date
Building Department Copy
September 24,2015 1
4
o Miami Shores Village
SEP 2 ,
Building Department BY: _
10050 N.E.2nd Avenue,Miami Shores,Florida 33138 -- '
Tel:(305)795-2204 Fax:(305)756-8972 /�
INSPECTION LINE PHONE NUMBER:(305)762-4949 j_ 1
FBC 201c
BUILDING Master Permit No. SLC (5— 2NO Z
PERMIT APPLICATION Sub Permit No.
❑BUILDING 54ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
PLUMBING ❑ MECHANICAL OPLIBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR , I ,{DRAWINGS
LL
JOB ADDRESS: l t 3�� '� = -� �RO � (,�'l� � 334
Citv: Miami Shores County: Miami Dade Zip: 3--y("4
Folio/Parcel#: Is the Building Historically Designated:Yes NO
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER:Name(Fee Simple Titleholder): A ✓ i e-,S Phone#:
Address: /t/3� Mc Z-^ n AlV
City: /�'�F�Hti+' �Y� State: Zip: 3 l G
Tenant/Lessee Name: Phone#: _� _ 1��4 — 3 Z
Email: S4a'yip-p
CONTRACTOR:Company Name: �� /���J -Tor, Phone#: r3 eL)7
Address: 1:�0 70 8 Z
City: Ml �� .�P� State: ��, Zip:
Qualifier Name: '40—-e"(f �i Phone#: 78(, ��7 Y7
7
State Certification or Registration#: 4� Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit:$ off, `J��• Square/Linear Footage of Work:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work: ft R-E A LN 19A SF.�JS 0 j2= REPLA G E µms/ E
Specify color of color thru tile:
Submittal Fee$ "'" Permit Fee$ 1;4 00 CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$
TOTAL FEE NOW DUE$ I I !, ' a
(Revised02/24/2014)
Bonding Company's Name(if applicable)
Bonding Company's Address _
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after th9lbuilding permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will b harged.
Signature Signature
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
day of�_ 7 20 1� ,by l U '' lav of
who is personally known to _,A.e �t.� jb�is!p:e�rsonally known to,;'
me or who has produced %%0._�ffkftw. as me or who has produced as
identification and wh id tai identification and who did take an oath.
NOTARY PUBLIC: $ ;�►, �- i. % NOTARY PUBLIC:
Si Sign:
OQ
PrinPrint•
!� ••' �� N D
•
ti/%/ I�I������N� a EXPIRES:December 1,2016
Seal: Seal: of F ' Bonded Thru Notary Public Undenvrltgrs
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014)
NOTE: A L H SETCM) U BE EVIEWED
MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES
Herbert S. Saffir Permitting and Inspection Center
11805 SW 26th Street(Coral Way) • Miami, Florida 33175-2474 • (786)315-2000
APPLICATION FOR MUNICIPAL PERMIT APPLICANTS
THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE
AND/OR ENVIRONMENTAL SERVICES
PROVIDE MUNICIPAL PROCESS NUMBER HERE
a Job Address DCS /�E7 ¢z Contractor No. ���9 7 �
o z / o o Last four 4 di its of Qualifier No. i �G
z W Folio �! a%3 C7 — C7OD on5c) � ( ) g
o W a Q Contractor Name 141 r�S
a o Lot Block F
Qualifier Name �'`'� _ '
O a Subdivision PBpg zp LL J
j 2 v z Address 1 c5"7
Metes and bounds City � ' State ruip3 0
.
[ ] New Construction on [ ] Demolish
F Vacant Land [ ] Shell Only Current use of property .r> i UerS i
Uz [ '] VtpKkion Interior [ ] Addition Attached
•Ej [ ] AR2ration Exterior. [ ] Addition Detached Description of Work
• �s [ ]RsIaG$tion of 9tructa�•re [ ] Re-Roofliry�
•. a [ ] ffr closure ; [ ] Foundation Only
• ...... Sq. Ft.I goo Units � Floors—
Re
pai� [ ] Tent
•... [ ]•Qepji?Due ts"rO• Value of Work o r-) - C3t�
• . • •••
00
•• [ ]•ve%l " N [ ] Chg. Contractor W Owner 1;orw 0-0 11'e 9t?
•• Ll
I. Oetegory F [ ] Re-Issue a Address
• [ 1VII;r� ••:•.. [ ]
✓} Re-Stamp City State Zip
••.. [ ]•MIrP� :•,"• w [ ] Revision w Phone
a [
-Mum w [ ] Not Applicable for 3 Last four(4)digits of
[ ] FIRE ¢ Fire o Owner's Social Security No.
N Name I Owner
z
o gv N w w
Address Address
z a
w Y City 1 ti I State��Zip �d I l-� v Z City State_Zip
0.0X LU
3: Phone 2).C S (oo , _ G-7 -7 a Phone
z 1 am requesting a Special Request Plan Review(SRI)to be scheduled as soon as possible at the rate of$209 for the first hour
a g¢ and$71.50 per each additional hour in addition to the review fees. Minimum charge one-hour.
Tj vam
N w w 1 sl Request: Date:
LL w 2nd Request: Date:
31d Request: Date:
z
5 1 am requesting Optional Plan Review(OPR)to be scheduled as soon as possible at the rate of$75 for each discipline.
1L a Additional review fees may apply.
z�
03:15t Request: Date:
0 W 2nd Request: Date:
9 31d Request: Date:
12301-192 4/14
i
f
BUILDING PERMIT CATEGORIES
CATEGORY DESCRIPTION PERMIT TYPE
BUILDING
01 GENERAL BUILDING-COMMERCIAL MBLD
02 SUB-GENERAL BUILDING-RESIDENTIAL MBLD
08 CANVAS AWNING MBLD
10 COMMUNICATION TOWER MBLD
15 DEMOLITION MBLD
29 METAL AWNING &STORM SHUTTER MBLD
48 SCREEN ENCLOSURES MBLD
55 SWIMMING POOL MBLD
56 TENNIS COURTS(SURFACE PAVING) MBLD
86 TRAILER TIE DOWN MBLD
88 WALK-IN COOLER MBLD
91 MARINAS MBLD
92 LOW SLOPE APPLICATIONS (GRAVEL, SMOOTH
MODIFIED, SINGLE PLY) MBLD
95 SHINGLES(ASPHALT, FIBERGLASS) MBLf[S`;�; •
96 SHINGLES(METAL ROOFS/WOOD SHINGLES&SHAKE) ,". MBLD
97 STAGE 2 VAPOR RECOVERY SYSTEM MBLi7":0 :400*:
99 SOIL IMPROVEMENT ��•;�;MBLD . '.
0100 BULK STORAGE PROPANE TANK MBLD •• ""'•
0101 REMOVABLE STORM PANELS ..:.•:MBL®•, "�_'••
0107 TILE ROOF ••••�MBLQ .
0110 WATER MAIN �•••• MBLD` •""`
0111 SITE PLAN ••':"MBLD•*,, .....•
0112 INDOOR EVENT/EXHIBIT •*6** MBLD. •..' •,
ELECTRICAL '...•` li
04 FIRE ALARM SPECIALTY MELE
16 SPECIALTY WIRING MELE
38 GENERATORS MELE
LPGX
01 LIQUEFIED PETROLEUM GAS MLPG
02 MISCELLANEOUS MLPG
04 LIQUEFIED PETROL. GAS/STATE MLPG
MECHANICAL
09 ABOVE/BELOW GROUND TANKS/PUMPS
&POLLUTANT STORAGE SYSTEM MMEC
38 COMMERCIAL HOODS MMEC
43 FIRE CHEMICAL MMEC
46 SPRAY BOOTHS MMEC
48 SMOKE CONTROL MMEC
52 RESIDENTIAL ELEVATOR MMEC
FIRE
32 FIRE SPRINKLER FIRE
U L N/_LL, Applicant ID No: 100039-032
Service Center No:1
Expires: 2016-03-31
SEP 2 2 2015
L"- _:•'00,00_-_. 0000 .-
CERTIFICATE OF COMPLIANCE
THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters
Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with
Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a
UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service.
This Certificate does not apply in any way to the communication channel between the protected property and
any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm
Transport Company is specified on the Certificate.
Listed Service From: MIAMI LAKES, FL
Alarm Service Company: (100039-032) Service Center: (100039-032)
CHI ALARMS INC. CHI ALARMS INC.
14070 NW 82ND AVE 14070 NW 82ND AVE
MIAMI LAKES FL 33016-1547 MIAMI LAKES FL 33016-1547
The Alarm Service Company is Listed in the following Certificate Service Categories:
File-Vol No. CCN Listing Category
S24065-1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling
Services)Central Station
0000..
0000.. 0000....
0000 0000
0000.. 0000....
0000....
0000....
0000.. 0000
0000.. . .0 00000
0000.... 0000 00 0000.00 0
0000 0000 0 00 000
00.0
0000....
. . . 0 0000..
0000....
.00
. 00. ..
. 0
00 .
00 . 0 000 0 0
0
0000
***THIS CERTIFICATE EXPIRES ON 2016-03-31***
"LOOK FOR THE UL ALARM SYSTEM CERTIFICATE"
007553
Local Business Tax Receipt
Miami—
Dade County,n
tYr
tate
of FloridaF1ori
d
-THIS IS NOTA BILL - 00 NOT PAY
3999365 ��LBT �/
�+
BUSINESS NAME/LOCATION RECEIPT NO. EXPIRES
CHI ALARMS INC RENEWAL SEPTEMBER 30, 2015
14070 NW 82 AVE 4173795 Must be displayed at place of business
MIAMI LAKES FL 33016. Pursuant to County Code
Chapter SA-Am 9&10
OWNER SEC.TYPE OF BUSINESS
CHI ALARMS INC 196 SPEC ELECTRICAL CONTRACTOR PAYMENT RECEIVED
EF0000876 BY TAX COLLECTOR
Worker(s) 2 $45.00 07/18/2014 ••
ECHECK-14-140144 •••
This local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license, ...••. '.;
permit,or a certification of the holder's qualificatioas,to do business. Holder most comply with any govermnentai •
or nongovernmental regulatory laws and requirements which apply to the business. ••••••
The RECEIPT NO.above must be displayed on all commercial vehicles-Miami-Dade Code Sec 8a-Z76. •""• ;'.
For more information,visit wwwmiamidade,gIlyttexcollector •••••• ••
RICK SCOTT,GOVERNOR KEN LAWSON,SECRETARY-
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
ELECTRICAL CONTRACTORS LICENSING BOARD
EF0000876
The ALARM SYSTEM CONTRACTOR 1
Named below IS CERTIFIED
Under the provisions of Chapter 489 FS.
Expiration date: AUG 31, 2016
0
CHI, RENE
CHI ALARMS, INC.
14070 NW 82ND AVE
MIAMI LAKES FL'33b16
ISSUED: 05/13/2014 DISPLAY AS REQUIRED BY LAW SEVS I!T405130001Z1 ;••••;
•
so 0
•
• • • • ••••••
00 0
-T-
(For
(For the protection of our professional license holders,this license contains hidden security features to prevent counterfeiting. Unauthorized
reproduction is strictly prohibited.and will be prosecuted to the fullest extent of the law)
The Department of Business and Professional Regulation(DBPR),issues licenses for many licensed businesses and practitioners in the State of
Florida.
DBPR is changing the way you interact with state government. Many of DBPR's services are available online at www.MyFloridaLicense.com.
We encourage you to utilize these services to make address changes,licensing changes or to renew your license.
Name changes require legal documentation verifying the name change,which must be mailed to the DBPR. An original,a certified copy or a
duplicate copy of an original or certified copy of a document that shows the legal name change will be accepted,unless the DBPR has a
question about the authenticity of the document.
If applicable,the DBPR will send a renewal notice to your last known address or email address of record. If you have not received your
renewal notice,please call our Customer Contact Center at 850.487.1395 or online at www.MyFloridaLicense.com/contactus.
Please refer to your profession's governing statutes and Administrative codes for further information regarding renewals. These may be
accessed from our website.
...... .... .
AC#, ; 4 i 9.7.4 6
...... .... ......
..... . .. ......
...... .. . .. ..
...... . . . .
CHI ALARMS, INC. Serving South Florida for Over 20 Years.
UL Listed Installer of Fire Alarm systems S24065. Notifier-Nesco/Fire-Lite Authorized
14070 NW 82nd Ave. Miami Lakes, FL 33016 Distributor
Tel: 305-827-2856 Fax: 305-825-2144
State License#EF0000876
Email: ibaezpardo@chialarms.com
Prepared by: Isaac Baez Pardo
NOTIFIERm
Proposal by Honeywell
Date: 8/27/2015
Attn: Yosef Shapiro
Job name: Browne Hall
Job address: 11300 NE 2nd Avenue, Miami Shores, FL 33161-6695
Tel/ Fax:
Email: Project:
Qty Description
1 Signed and sealed shop drawings.
1 Processing of fire alarm permit.
1 Electrical fire and fire alarm inspection only.
1 Labor to install, program and certify.
Excluded: Permit fees.
Thank you for your business otal $2500.00
1. Price cover only the material listed above.Any additional equipment shall be paid for by the Customer.
2. Sales are subject to CHT ALARMS,INC.standard credit terms and conditions.
3. Payments:50%deposit,25%at rough electrical inspection,15%at fire final inspection and balance at final electrical.
4. All payments are due upon receipt of invoice.On balance more than 30 days old,it is agreed that a Finance Charge of 1.5%per month will be made.Should the service of an attorney be required to enforce any part of a credit
agreement,or for the collection of a delinquent account,it is agreed that the Debtor will pay all costs of collection including attorney fees.
5. Equipment to become property of the Customer upon payment of Selling Price indicated above in full.
6. Customer to provide dedicated 110-volt line and 2 telephone lines to the FACP.
7. The above price is valid for 120 days from date of quotation.
8. All alarm equipment is warranty for one full year.
9. Local authorities may require additional devices.
10. Customer to supply building floor plans.
11. In no event shall Chi Alarms,Inc.be liable for any special,incidental,indirect,speculative,remote,consequential,punitive or exemplary damages,whether arising out of or as a result of breach of contract,warranty,tort(including
negligence)arising from,relating to,or connected with the services,equipment,materials,or any goods provided hereunder.
12. Notwithstanding anything to the wntrary herein,if a portion of the services involves the installation and/or maintenance of system associated with security and/or detection of and/or reduction of disk of loss associated with fire,Chi
Alarms,Inc.total liability arising out of or as a result of its'performance under this agreement shall not exceed the amount of this agreement.
13. Third Party Indemnification.When Customer has persons,or the property of otters on the premises,or the system extends to protect property or others,Customer agrees to and shall indemnify,defend and hold harmless Chi Alarms,
Inc.its employees and agents for and against all claims brought by parties other than the parties to this agreement.This provision shall apply to all claims regardless of rouse,including Chi Alarms,Inc.performance or failure to
perform and inducting defects in products,design,installation,maintenance,operation or non-operation of the System,whether based upon negligence,active or passive,warranty,or strict or product liability on the part of Chi Alarms,
Inc.its employees or agents,but this provision shall not apply to claims for loss or damages solely and directly caused by an employee of Chi Alarms,Inc.while on Customers premises.
14. Painting,patching and trenching if required not included.
15. Customer agrees to pay for any expenses incurred by Chi Alarms,Inc.due to interruptions in the installation and work schedule of the fire alarm system proposed due to customers inability to providCa"slto the project location
and installation area as per approved plans and design.Expenses include but are not limited to expired permits,failure to attend scheduled appointments,non-payment according to schedule of p4ments and9ailure or refusal to
authorize a change order and payment for additional work required by the authority having jurisdiction(AHJ).If additional work is required by AHJ and customer refuses to thori�,g SL h work within"4P Chi Alarms,Itjc�r�"s•
the right to proceed with the work as required by AHJ to complete the installation and close the permit.If this should occur customer acknowledges that Chi Alarms,Inc.roil I��9g�Ily erpktith to su yme�x(,as outlined in the
proposed change order.Customer understand that Chi Alarms,Inc.may place a hold on any existing open permit related to the work described above due to the customer in iility to provide acce�tao�e e7rti�installation area 99•
required.
18. Sales tax not included.
•••••• •••• ••••••
•
17. Permit fee not
included. •••••• • • •
;Osseo
•••• • •• •••••
Customer acceptance •••••• •• • •••••
In accepting this proposal the Customer agrees to the terms and conditions contained herein.It is understood that they shall pretttail Over any vari4ion ipi,?rms and:•••••
conditions on any purchase order or other document that the Customer may issue. •
• • • •see••.
Purchaser Signature Date
Bill to address Print name Title
City State Zip Telephone no.
1411111, Secutron",
CONVENTIONAL
FIRE ALARM CONTROL UNITS
MEN
MR-2300 SERIES
Features
Fire Alarm Control Units Listed to UL 864,9th edition- Available in six and
twelve zone models
• Available in LED and LCD Display configurations
• LCD Display versions are equipped with a 2 line
by 20 character back-lit LCD display and numerical
keypad
• Integrated UDACT/Digital Communicator on select
models
• Front panel and PC programmable
• LED Display versions are front panel(using CFG-300
configuration tool)and PC programmable
• Remote upload/download capabilities
• Base panel is equipped with Class `B" (Style "B")
initiating circuits which may be configured as Class
"A"(Style°D")using a Class"A"converter module
• Initiating circuits may be configured as Alarm,Verified
Alarm, Waterflow Alarm, Sprinkler Alarm, Latching
or Non-Latching Supervisory, Monitor and Trouble-
Description Only
Secutron's MR-2300 Series fire alarm control panels Base panel is equipped with Class 'B" (Style "Y")
consist of six and twelve zone models which are indicating circuits which may be configured as Class
equipped with a two line by 20 character back-lit "A"(Style`Z')using a Class"A"signal converter module
LCD display, numerical keypad and an integrated Audible signals may be configured for Steady,
UDACT/Digital Communicator. The MR-2300 family Temporal Code,California Code and March Time
also includes a twelve zone model that is equipped Indicating Circuits may be configured as Silenceable
with an LED display and an integrated UDACT/Digital or Non-Silenceable for both signals and strobes
Communicator. In addition the MR-2300 Series family Built-in sync protocols for the following strobe
includes remote LCD annunciators, LED annunciators manufacturers: Mircom, Amseco, System Sensor,
and remote smart relay modules. Gentex, Faraday and Wheelock
• Relay contacts for Common Alarm,Auxiliary/Alarm
The MR-2300 Series panels are ideal for both new and (Disconnectable), Common Supervisory and
. . 0000 .00000
retrofit applications. Designed for small to medium Common Trouble
commercial, institutional and industrial occupancies, Configurable Signal Silence•�nhibit,:Awfo Gignal•••��•
these panels are powerful enough to meet today's Silence and One-Man AaTk test
installation demands. The MR-2300 Series panels are Subsequent Alarm, Supg0Yisory, §nd•lrouble;••••:
configurable by the keypad for onsite programming or operation •
0000 . .. 0000.
by a PC for both onsite and remote programming. Easy RS-485 Interface for Rerr}pjP."PAnnVpiatgrs,LCD.•;•••
to install and simple to operate and configure,the MR- Annunciators and Remo"SUArt Rel*IClpdeles ......
2300 Series panels enable the installer to configure the Two event history logs :el�irised of a 200 event
system to meet their specific requirements. alarm log for alarm related events and a 200 event••••••
I
general log for all other tem. 0000.0 •
The MR-2300 Series panels are equipped with a 5 Amp 5 Amp Power Supply •• • :0:
••••
power supply, 4-wire resettable smoke power supply Optional modules for additional internall"ayCircuits
(300mA max.)and an RS-485 interface for remote LCD and City Tie/Polarity Reversal
annunciators, LED annunciators and Remote Smart Optional trim rings for semi-flush mounting
Relay modules.
All MR-2300 Series panels come complete with a red '
door, black enclosure, durable CAT-30 lock and keyOSA MEA
and space to mount up to 12 AH batteries. Optional L approved
trim rings are available for semi-flush mounting. 56619 56619 7165-1656:129 352-03-E
(LED Models) 7165-1656:131
Issue 4 SECUTRON Page 1 of 6
Canada 25 Interchange Way,Vaughan(Toronto),Ontario L4K 5W3 Telephone:(905)695-3545 Fax:(905)660-4113• Web Page:www.secutron.com
U.S.A. 4575 Witmer Industrial Estates,Niagara Falls,NY 14305 Telephone:(888)695-3545 Fax:(888)660-4113• E-mail:mail@secutron.com
Catalog Number 1019 • Not to be used for installation purposes.
Features
Initiating Circuits Indicating Circuits
The MR-2300 Series panels are equipped with Class The MR-2300 Series panels are equipped with
"B" (Style"B") initiating circuits. The initiating circuits equipped with Class"B"(Style"B") indicating circuits.
may be configured as Class "A" (Style "D") using an The indicating circuits may be configured as Class"A"
MR-2300-A Class"A"converter adder module. (Style "Z") using an MR-2300-NC4 or MR-2300-NC2
Class"A" signal converter adder module.The audible
Each Initiating circuit may be configured for one of the signals may be configured for Steady,Temporal Code,
following modes of operation: California Code and March Time.
• Alarm (Without smoke detector verification) Each of the indicating circuits may be configured for
Verified Alarm (With smoke detector one of the following modes of operation:
verification)
• Waterflow Alarm (Water flow sensors) Silenceable Signal
• Sprinkler Alarm (Sprinkler flow sensors) ' Non-Silenceable Signal
Latching Supervisory • Silenceable Strobe
Non-Latching Supervisory • Non-Sileneceable Strobe
• Monitor(non-latching input used mainly for
correlating to a relay circuit) The MR-2300 has built-in sync protocols for the
• Trouble-Only(for monitoring a trouble condition following strobe manufacturers; Secutron, Amseco,
from an external device) System Sensor, Gentex, Faraday and Wheelock.
13 Series Protocol UDACT/Digital Communicator
The MR-2300 Series panels have the i3 Series protocol The MR-2300 Series panels are equipped with a fully
built-in. The panels support the two-wire i3 Series integrated UDACT/Digital Communicator which allows
smoke detectors (2W-B/2WT-B). These i3 series for the reporting of events to a monitoring facility. The
detectors communicate with the MR-2300 to provide UDACT/Digital Communicator can be configured for
the following status information: single or dual line operation and uses the Security
Industry Association (SIA) and Ademco Contact ID
Open circuit trouble protocols. The UDACT/Digital Communicator is
This trouble indicates that loop is broken. configured via the main display and keypad on the
main panel.
Comrawaication trouble
...... Thislwx"e indicates that there is a fault in the line or In addition to its reporting functions, the integrated
•:•••• the with it a lis Iloo s sy•t.. panel cannot communicate UDACT/Digital Communicator can be used to connect
to the MR-2300 panel from remote computers for
• ••••••• uploading and downloading of configuration data. It
• Dirtyde;ief 000000
also allows for the viewing of the event history logs.
••••• This trouble indica%rthat one or more device on the The MR-2300 series panels have two event history
••••• i3 zope ip*grty. ::-:-- logs comprised of a 200 event alarm log for alarm
•••••• •' " '• related events and a 200 event general log for all
•• Out of Sensitivity:': other events.
•""• This.t"4 indicates that one or more device on the
i3 zone is But of caositivity range and cannot detect The integrated UDACT/Digital Communicator can be
an aINH condition. •• configured for either DACT or UDACT operation. In
• •0 DACT mode the Digital Communicator reports common
Freeze trouble alarm,trouble and supervisory information. In UDACT
This trouble indicates that a device on the i3 zone has mode the Digital Communicator reports point specific
detected a freeze condition, e.g. the temperature is information.
below 41 OF/5°C (available only on model 2WT-B).
The built-in protocol removes the need for the 2W-MOD
Maintenance Module.
Page 2 of 6 SECUTRON Issue 4
Catalog Number 1019
Not to be used for installation purposes.
MR-2300 Series LCD Version Models
MR-2306-DDR Six Zone LCD Display Fire Alarm Control MR-2312-DDR Twelve Zone LCD Display Fire Alarm Control
Panel Panel with UDACT/Digital Communicator
The MR-2306-DDR is equipped with six Class "B" (Style "B") The MR-2312-DDR is equipped with twelve Class"B"(Style"B")
initiating circuits and two Class"B"(Style"Y")indicating circuits initiating circuits and four Class"B"(Style"Y")indicating circuits
rated @ 1.7 Amps maximum.(Total of 5 Amps) The MR-2306- @ 1.7 Amps maximum.(Total of 5 Amps). Two MR-2300-A Six
DDR is equipped with a built-in UDACT/Digital Communicator. Initiating Circuit Class AConverter Module may be used for Class
One MR-2300-ASix Initiating Circuit Class"A"Converter Modules "A"(Style"D")wiring of the initiating circuits.One MR-2300-NC4
may be used for Class "A" (Style "D") wiring of the initiating Four Indicating Circuit Class"A"Converter Module may be used
circuits. One MR-2300-NC2 Two Indicating Circuit Class "A" for Class "A" (Style 7') wiring of the Indicating circuits. The
Converter Module may be used for Class"A"(Style"Z')wiring MR-2312-DDR has a built-in UDACT/Digital Communicator and
of the indicating circuits. The cabinet will support up to 12 AH the cabinet will support up to 12 AH batteries. The panel can
batteries.The panels can be semi-flush mounted with the optional be semi-flush mounted with the optional MR-2312-FT trim ring.
MR-2300TRB trim ring. Note:Not ULC listed. Note:Not ULC listed.
Dimensions Dimensions
MR-2306-DDR: 20"H x 14.5"W x 4.5"D MR-2312-DDR: 26"H x 14.5"W x 4.5"D
MR-2306-FT: 22.5"H x 17"W MR-2312-FT: 28.5"H x 17"W
R-2300 Series LED Version Models
MR-2312-LDR Twelve Zone LED Display Fire Alar Control
Panel with UDACT/Digital Communicator 0000
The MR-2312-LDR is equipped with twelve Class� B'4Style "B").+•++.
initiating circuits and four Class"A':(STyle"Y")indicating circuits ,•
rated @ 1.7 Amps maximum.(ToWlOf5pps)T'v9:4FJ2300-A....;.
Six Initiating Circuit Class"A"ConjWAUpdules may 4e used for. •
Class"A"(Style"D")wiring ofthe init4ogg circuits.ppe 14R-2300-:••••;
NC4 Four Indicating Circuit Clas!f&90verter rrodg%may bei....
used for Class"A"(Style"Z")wiring of the indicating circuits. The • +
MR-2312-LDR is configurable bythekeaped(usirFtke 6FG-300
:
Configuration Tool)for onsite pro��99rmming or by a PUfor both* :•
onsite and remote programming.TihM312-LDR has a built-in ••
UDACT/Digital Communicator and the calbinet W:1"plkirt up to••"'•
12 AH batteries.The panel can tt-sep$,llush maunted with the;,...;
optional MR-2312-FT trim ring. •• • .. :0: • •
Dimensions •
MR-2312-LDR: 26"H x 14.5"W x 4.5"D
MR-2312-FT 28.5"H x 17'1N
Issue 4 SECUTRON Page 3 of 6
Catalog Number 1019
Not to be used for installation purposes.
Remote nnunciator
MR-2306-ATR/MR-2312-ATR Remote LED Annunciators
The MR-2306-ATR and MR-2312-ATR provide 8 or 16
points respectively of LED annunciation. Both models
MR-2300-LCDR Remote LCD Annunciator feature bi-coloured LEDs which are auto-configurable
The MR-2300-LCDR provides LCD remote annunciation for either Alarm (red) or Supervisory(amber). The LED
through a 2 line by 20 character LCD display. The MR- annunciators have indicators for A.C. On, Common
2300-LCDR provides control switches for System Reset, Trouble and Signal Silence and control switches for
Signal Silence, Fire Drill and Acknowledge as well as System Reset, Signal Silence, Lamp Test and Buzzer
a numeric keypad to access the menu functions. The Silence. The MR-2306-ATR and MR-2312-ATR are
common control functions can be disabled on a per equipped with a keyswitch which allows for enabling
function basis. The MR-2300-LCDR has LED indicators and disabling of the Common Control functions. Both
for A.C. On, Alarm, Supervisory, Trouble and CPU models are available in a red finish and mount in a 4-gang
Fail. The MR-2300-LCDR comes complete with a red electrical box. Note: ULC Listed as an Ancillary Device.
enclosure and a CAT-30 Lock and key. Note:ULC Listed
CID Vi
as an Ancillary Device.
RAM-1016TZDS Remote LED Annunciator
The RAM-1016TZDS Remote LEDAnnunciator provides 16
points of LED annunciation. The RAM-1016TZDS comes
standard with bi-coloured LEDs which are automatically
configured for either Alarm (Red) or Supervisory(Amber)
• and individual trouble LEDs. The RAM-1016TZDS has
• •••• MR-28�T�•9R12 9martftelay Module indicators forA.C.On,Common Trouble and Signal Silence
• The MR�P612-SRitpre�ides twelve configurable relay and controls for System Reset,Lamp Test,Fire Drill,Buzzer
•• Silence and Signal Silence. In addition it allows for the control
• •; circuitsorated @ 281PDC'1 amp(resistive). Each circuit switches to be disabled on a per function basis.The RAM-
can 4ecgr?fJ]ured a5&"gmally Open(N.O.)or Normally 1016TZDS mounts in a MMX-BB-1001 R enclosure.
00;00 Closetl'(N.C.)contcWt*r=ach relay is equipped with an
••"• LED.thatnit wh&Wrelay is energized. The relays
can bg configured 99 re1Ay per zone(1 to 1), Common "� m
.... _
on Alarin, Common on.Supervisory or programmable
"'• for aA(bs ;)r adjacent zone configuration. An adjacent
:....: zone confiratioroUl turn on an adjacent zone when
• • the oonliqured zone is active. A chaining configuration CFG-300 Configuration Tool
allows for multiple relays to turn on. The MR-2312-SR12 The CFG-300 Configuration Tool is rewired for onsite front
is DIP switch configurable and connects to the RS-485 panel programming of the MR-2312-LDR panel.The CFG-
bus. The MR-2312-SR12 comes complete with a red 300 plugs into the MR-2312-LDR main board to provide a two
enclosure and a CAT-30 lock and key line by 20 character LCD display. The MR-2312-LDR panel
is configured using the CFG-300 and push buttons on the
main board. In configuration mode,the initiating and indicating
circuit disconnect buttons act as function keys. Removing the
zone labels reveals the programming function buttons. The
CFG-300 tool is used for configuration purposes only and not
for normal operation.
Page 4 of 6 SECUTRON Issue 4
Catalog Number 1019
Not to be used for installation purposes.
Adder Module
I, I
MR-2300-A Six Initiating Circuit Class"A"Converter MR-2306-R6/MR-2312-R12 Relay Circuit Adder
Module Modules
The MR-2300-A converts six Class`B"(Style"B"initiating The MR-2306-R6 provides six configurable relay circuits,
circuits on the MR-2300 main board to Class"A"(Style"D") rated @ 28 VDC, 1 amp (resistive). The MR-2312-R12
circuits. The MR-2300-A is equipped with wire leads to provides twelve Form C configurable relay circuits,rated @
connect to the MR-2300 main board. It mounts to the right 28 VDC,1 amp(resistive). On both models each circuit can
of the main board Class"B"(Style`B") initiating circuits. be conf igured as a Normally Open(N.O.)or Normally Closed
Two MR-2300-A modules are required to convert all twelve (N.C.)contact. Each relay is equipped with an LED that is lit
initiating circuits on an MR-2312 series panel. when the relay is energized. The relays can be configured
as relay per zone(1 to 1),Common on Alarm,Common on
I I Supervisory or programmable for logical or adjacent zone
configuration. An adjacent zone configuration will turn on
_0000
adjacent zone when configured zone is active. A chaining
configuration allows for multiple relays to turn on.
� srssr
sr.'.
MR-2300-NC4 Four Indicating Circuit Class "A"
Converter Module
The MR-2300-NC4 converts four Class"B"(Style"Y")
indicating circuits on the MR-2300 main board to Class MR-2300-PR Polarity Reversal/City Tie Module
"A"(Style"Z")circuits. The MR-2300-NC4 is equipped The MR-2300-PR provides outputs for city box and polarity
with wire leads to connect to the MR-2300 main board. reversal applications.As a city tie module the MR-2300-PR
It mounts to the right of the main board Class"B"(Style provides an interface between the control pane�iritlicating
"Y") indicating circuits and is used with the MR-2312 circuits and a master box. It provide soff-prerrrrees signal•••• •
series panels. transmission for systems thatsmust•comply Vitlt NFPA ••
requirements forAuxiliaryProtediel Systems.066 clarity....
••
reversal module the M R-2300-PR pfovides an Interface; ;
between the control panel ancL316ftse polafl1r fteivec' •
It provides off-premises signal Mahtmissiorf for'Systems*
....,,.1,....., hull_ :00
that must comply with NFPA ruMVftents.
.. .. . *0 00000
0000..
00000
6
0
0000..
0.00.0
. ...
0000..
MR-2300-NC2 Two Indicating Circuit Class "A"
Converter Module
The MR-2300-NC2 converts two Class"B"(Style"Y") MR-2300-X Active End-of-Line Resistors
indicating circuits on the MR-2300 main board to Class The MR-2300-X are power saving End-of-Line resistors
"A"(Style"Z")circuits. The MR-2300-NC2 is equipped which eliminates the need for an additional battery cabinet
with wire leads to connect to the MR-2300 main board. or larger batteries in order to meet the 60 hour standby
It mounts to the right of the main board Class"B"(Style requirement. (Please refer to Battery Calculation Chart in
"Y") indicating circuits and is used with the MR-2306 manual formore details.)The MR-2300-X can also be used
series panels. when larger batteries than can fit in the cabinet are required.
Issue 4 SECUTRON Page 5 of 6
Catalog Number 1019
Not to be used for installation purposes.
Specifications
AC Input Unfiltered supply(full wave rectlfi )'
120VAC @ 60Hz Power limited/24VDC unfiltered/1.7A max at 49°C
Standby Power Auxiliary Relays(Common alarmJs /trbJand auxiliary
24VDC standby batteries second alarm)
Charging Capability FormC/28VDC/1 A max
4 to 12 AH Current Consumption
Indicating Circuits Model Standby Alarm
Power limited/24VDC unfiltered/1.7A @ 49*C per MR-2306-DDR 142 mA(112 mA*) 312 mA(282 mA*)
circuit. Maximum 5 Amps. MR-2312-DDR 174mA(104 mA*) 444mA(394 mA*)
Aux supply{non resetabie} MR-2312-LDR 11 64m(104 mA*) 424mA(364 mA*)
Power limited/22.3VDC regulated/500mA max
4-wire smoke supply{resetabie}
Power limited/22.3VDC regulated/300mA max
Ordering information
Moftl Description
Control Units
MR-2306-DDR* Six Zone LCD Display Fire Alarm Control Unit with built-in UDACT/Digital Communicator
MR-2312-DDR* Twelve Zone LCD Display Fire Alarm Control Unit with built-in UDACT/Digital Communicator
MR-2312-LDR Twelve Zone LED Display Fire Alarm Control Unit with built-in UDACT/Digital Communicator
Remote Annunciators and modules
MR-2300-LCDR Remote LCD Annunciator(Red enclosure)(Note: ULC Listed as an Ancillary Device.)
MR-2300-LCDW Remote LCD Annunciator(White enclosure)(Note: ULC Listed as an Ancillary Device.)
MR-2306-ATR Eight zone Remote LED Annunciator(Note: ULC Listed as an Ancillary Device.)
MR-2312-ATR Sixteen zone Remote LED Annunciator(Note: ULC Listed as an Ancillary Device.)
RAM-1016TZDS Sixteen zone Remote LED Annunciator with individual Trouble LEDs
MR-2312-SR12 Remote Relay Module with red enclosure
MMX-BB-1001R Red enclosure for RAM-1016TZDS
i Adder Modules
*:*sea• MR--=jR • $ix Initiating Circuit Class"A"Converter Module
MR-1W04MC4 • %ePour Indicating Circuit Class"A"Converter Module
• •••• MR-2300•NC2 •••• Two Indicating Circuit Class"A"Converter Module
•...; MR-2$b6-R6 ••'• six Relay Circuit Adder Module
•••••
MR•231Q-412 • Vwelve Relay Circuit Adder Module
•••;•• MR-?x300;;R •••, I;olarity Reversal/City Tie Module
.....• MR•"U-Ai ••• active End-of-Line Resistor
•
•
• Accestsories •....•
•••••• MRS ;li ' Black Semi-Flush Trim Ring for MR-2306 enclosures
:...•: MR-2312- *me glack Universal Semi-Flush Trim Ring for MR-2312 enclosures
• •
CF(:-30p, Configuration Tool for MR-2312-LCDR
UIMA Universal Programming Tool
Note:Not ULC Listed
Page 6 of 6 SECUTRON Issue 4
Catalog Number 1019 • Not to be used for installation purposes.
Secutron reserves the right to make changes at any time without notice in prices,colors,materials,components,equipment,specifications and models and also to discontinue models.
I!V)luf! :':i:)i5 '-b,
� � r
dY
® i
r L i +IM
�a.
Features That
Make a Difference:
• Uses HSPA(3G)network for
high-speed, reliable and low-
cost communications to an IP
receiver
• Automatically switches to 2G
(EDGE/GPRS) if 3G service is 3G technologyfrom DSC!
not available
• Compatible with control panels The 3G3070CF connects the alarm path shall be annunciated at the
that communicate using the control panel to the HSPA network supervising station and at the
Contact ID format and reports alarm signals directly to a protected premises within not more
• Full event reporting monitoring station receiver(Sur-Gard than 24 hours of the failure.
System I/II/III/IV).The 3G3070CF uses
• 4 on-board'inputs the HSPA network to ensure low- How it Works
• 4 on-board outputs(open cost, high-speed and reliable alarm The 3G3070CF can be used as
collector) communications and is compatible either a Sole Communicator or as a
SIM card(included) with control panels that communicate Backup Communicao.*Vftn being
•
Activation and initialization via using the Contact ID format. used at a W(i CommtWttor the....
•
automated telephone activation
The 3G3070CF is compliant 3G3070t�A replace the phone •.
...... .... ......
system (VRU), web-user or with the latest requirements for line co 1*6 0.0�on the pad el and •
Communications Methods as as soon a�jt detects.tDat in alarm:••••
mobile interface provided by per UL864 and NFPA72 2010 needs c 1 sen
C24 Communications ��e�nsmi� �� d";".
Edition. It can be used in Fire the alar"ociiipss the"SPA netwo4.�..
• PTM (Panel Transmission Monitoring applications as a single immediatel)iAhen btin'g.us'ed as a.....
Monitor)switches from PSTN communications technology, backul3p#*> ornmunicator assesses •
to cellular on unsuccessful in which case any failure of the the cormectiom to tha PSTN phone••• •
communication attempts communications path shall be line,anV orgy O the event of a phole, •
• ® annunciated at the supervising station line failurt'Will Tt sendo V�traffic
System I/II/III/IV monitoring •
Compatible with SunGardtoring within 5 minutes of the failure,or it across the HSPA netwbfk 0 the
station receivers can be used as part of a multiple monitoring station.
communications technologies(for In instances where the control panel
• Includes UL listed power example in conjunction with a DACT). does not support Contact ID,the
supply,transformer and 7 Ah When used as a back-up provision 3G3070CF has inputs pre-set to
rechargeable battery shall be made to monitor the integrity transmit fire alarm,fire supervisory or
• UL 864 listed of each communication path and system trouble.
CSFM listed failure of any communications
•
C;
_..... ..
Alarm signals are transmitted directly without the need of Specifications
a clearinghouse to the IP linecard of the monitoring station
receiver(Sur-Gard®System I/II/III/IVj. Dimensions................................................11-1/2"x 10"x 3"
(29.2 cm x 25.4 cm x 7.62 cm)
Activating & initializing the unit Input Voltage.............................................................120 VAC
Activating and initializing the 3G3070 can be done using Current Draw..............................................................300 mA
the automated telephone activation system(VRU), mobile Operating Environment ................0°to 48°C(32°to 120°F)
interface or web-user interface provided by CONNECT 24. Weight...........................................................12.8 lbs(5.8 kg)
No special tools are required.
UL Listing
The 3G3070CF is UL listed under File S4019, Listing
guide UOXX,as a sole or backup communicator for
Commercial Fire monitoring installations.When used as a
sole communicator the 3G3070CF will send its heartbeat
once every 97 seconds ensuring that three heartbeats
will be received at the supervising station within the 300
second window.When used as a backup communicator the
3G3070CF will monitor the other communication method
(DACT)and send a daily test transmission to the supervising
station.
CSFM Listing
The 3G3070CF has been approved by the California State
Fire Marshal(CSFM)pursuant to Section 13144.1 of the
California Health and Safety Code.
Rate Plan
....
...0a6t-effec%v .ra?e plan have been negotiated and are
•o
available thrtougjauthonzeclrnaster resellers.Contact your
• •"mitoring",Itbn or viE01% .connect24.com to find a
"43ter reselibr. 6 6.9 0•
••
0rde0hg*0nforMW6n:
... .. .. . .. ..
3G3070CF.USA.....Uoiiaeo9ek Wireless Commercial Fire Alarm
•:• •• • • Communicator(U.S. Model/SIM Card
• • • IWedi
• i •
0
N
V
8
0
m
a •OnrnUni ations
SG=32/42SK Series
PUSH
Die-Cast MetalPUL PULL
IPStationsManua till
Single Action Dual Action
Descdpticrt
The SG-32SK and SG-42SK Series are single contact,key-reset,manual -,.'t s
pull stations designed to meet the requirements for many applications.
They are constructed from a rugged,but lightweight,die-cast metal alloy • Single or Dual Action
for increased performance and longevity. This series of stations is available
in single action(PULL lever)or dual action(PUSH bar and PULL lever)
models. • Screw Terminal Connections
The series of stations represented on this data sheet (SG-32SK or SG- . DC and AC Voltage Contact Ratings
42SK) are provided with one normally open contact connected to a
terminal strip that can accommodate wiring from#22 to#12 AWG. (See
Spectrum data sheet for additional contacts). Contacts are gold plated • Gold Plated Alarm Contacts
to minimize risk of corrosion. All models have been tested by UL and
found in compliance with the pull force requirements of the Americans • Surface or Weatherproof Back-box
with Disabilities Act(ADA). p
• Deeper Back-boxes available to
Coiwcdion
provide more space for wire and/or
The stations are operated by pulling the handle marked"PULL"on the •addrevable moduli;:':•
front of the unit as far down as it will go. At that point,the handle will •• ......
lock in place and is easily visible from up to 50 feet. The activation •• • : •*00 •0
handle is reset by opening the station with the key,placing the"PULL" • OptiontMI ton ColOf oLabels T'••0
handle to its normal upright position (resetting the toggle switch when *00***
••••• ••
applicable)and relocking the station. On the dual action,the"PUSH"or ContaCtt..�$ee $p9C�ulll data SO@ .
optional"EMERGENCY"bar moves inward allowing the"PULL"handle
to be operated by a single hand. - moi:. '. 00000
MourN Confrgc�cs
••••
Semi-Flush--All models mount on a standard single-gang back-box. Pt111. •••:
Surface Mount Interior--Use SigCom SGB-32S or the deeper metal
back-box(SGB-32SD).
Surface Mount Exterior--Use Si Com SGB-32C SG-WP or the
g ( )
deeper die-cast, weatherproof back-box (SGB-32CD)
STl1.
c L usQ= FM MEA
•,• �
R vt
NYC Approved Signal Communications Corporation
LISTED APPROVED
SGO53008
„ �Cr�Ct7f(t7�7S .
Listings: UL,ULc,FM,CSFM,MEA
Temperature: -40°to 150°17,90%relative humidity @ 100017
Switch Rating:
SG-32-Micro switch 1 Amp @ 30 VDC,1 Amp @ 125 VAC
SG-42-Toggle switch 2Amps @ 125 VDC,2Amps @ 240 VAC
Pull Station Weight: 1.2 lbs
Pull Station Dimensions: 4 3/4"h x 3 1/4"w x 1.1"d
Surface-Mount Backbox Dimensions: 4 3/4"h x 3 1/4"w x 2 1/4"d(outside);2 1/8"d(inside)cast and sheet metal
Deep Surface-Mount Backbox Dimensions: 4 3/4"h x 3 1/4"w x 2 3/4"d(outside);2 5/8"d(inside)cast and sheet metal
Color. Red with raised white letters,white"PULL"bar and white"PUSH"bar(Dual
Action)with raised red letters
Cnh>rm
3-Micro switch SG- -- SK-- - -- - .
4-Toggle switch
Blank-Standard lock("B"key)
2-Standard pull station
6-"EMERGENCY"push bar in place of"PUSH"bar
A-Cat 15 lock assembly D-Cat 60 lock assembly
B-Cat 30 lock assembly E-SC 10 lock assembly
C-Cat 45 lock assembly F-PK525 lock assembly
00 -No logo
SC-SigCom logo
I-Dual action
2-Single action
Example: SG-32SK2-SC=Micro switch,standard,single action,SigCom logo with standard`B"key lock
Note: All stations are supplied with one break-rod,one key and installation instructions
Accessories
SGB-32S ••••0 Interior,red,surface mount,sheet metal backbox with 3/4"knockouts
%13-32SDDeep-etegQ;!red,surface mount,sheet metal backbox with 3/4"knockouts
•e•CCaWP 0#410 WeatheP48("red,surface mount,die-cast metal backbox with one tapped hole for 3/4"NIPT fitting(same as SGB-32C)
• • 0000••rp
:00_1+32CD 6 ,Deep Wee j*UO* red,surface mount,die-cast metal backbox with one tapped hole for 3/4"NPT fitting
:_-;MR0I *660 612 packbfSeored,plastic(acrylic)break-rods for spares or replacement
0000• • 06 •09.09
••0906 •• • •• ••
:0609.e Speehx:aeries'data s9eet
0000•• • • • ,
• • • �', t.)ll
For New York City MEA listed stations, see NYC Stations data sheet
Signal Communications Corporation
P.O.Box 2588 Woburn,MA 01888 Tel.:781 933 0998 Fax.:781 933 5019 SGO53008
COOPER Notification
00
Weatherproof Appliances - Series AH Audibles,AS Audible Strobes, MT Multitone Strobes,
RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories
l
Description:
Designed for life safety, performance and reliability, Cooper All models may be synchronized using the Wheelock DSM Sync
Notification's Wheelock cost effective weatherpoof notification Modules, Wheelock Power Supplies or other manufacturers
appliances include: panels incorporating the Wheelock Patented Sync Protocol. The
Weatherproof Appliances Series horn output of horn strobes can be independently controlled on
2-wire circuits using the Wheelock patented sync protocol. MTWP
Strobes RSSWP horn strobe models are 4-wire appliances; the strobes can be
Horn Strobes ASWP synchronized while the audible can be connected to a coded fire
Horns AH-24WP,AH-12WP alarm system or can be set to produce any of eight selectable
Multitone Horn Strobes MTWP tones.
Multitone Horns MT
Speaker Strobes ET70WP
Speakers ET-1010 Features:
All strobe models are UL dual listed meeting both UL1638 Approvals include: UL Standards 1971, 1638,464 and 1480
and UL1971 requirements. As dual listed appliances, these California State Fire Marshal(CSFM), New York City
weatherproof strobes, horn strobes and speaker strobes are listed (MEA), Factory Mutual(FM), Chicago(BFP)and ULC. See
for outdoor applications under UL 1638 as well as under UL 1971,
the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this
With an extended temperature range of—31°F to 150°F (-35°C document
to 66°C), Wheelock weatherproof appliances meet or exceed UL 0 Compliance with the following requireWm". NFPA, UFC,
outdoor test requirements for rain,humidity and corrosion resistance ANSI 117.1, OSHA Part 29, 1910.165 ADA• ••••••
while providing multiple strobe intensity options, including the • •
highest strobe ratings available for area coverage per NFPA 72 Weatherproof with exten88d terrlperatra Fite of-40°F'to
strobe spacing tables(up to 185 candela forwall mounting and 177 150°F(-40°C to 66°C)*"';'• "'• ""'•
candela for ceiling mounting). • Dual Listed strobe models(rUL 1638 a . 00 0
• • •
To enable weatherproof mounting, Cooper Notification provides 0 Industry's highest strobe gppdLla optianS..' .�...
the industry's widest choice of mounting options for surface or 0 Synchronize using the VW�=eic�k SyntNodules or p>s�els• •
unique semi-flush installation. Models are available for surface � •
mounting to Wheelock weatherproof backboxes on walls or ceilings. with built-in Wheelock Patented SynA-rotocol ......
The optional WP-KIT allows the weatherproof backboxes (106, 0 Models with field sele4bnfte,dBA and candela settiAQs
WPBB or WPSBB) to be mounted to a recessed electrical box Wall or ceiling mountin•options :•••:• 000000
for concealed conduit installation. For semi-flush installation, the g ,� p . .
WPA'and WFPA"kits allow a customer to mount the weatherproof Surface of semi-flush r1'Iptyitinj . ... ;••••;
appliances to a recessed electrical box without the need for an IN/OUT wiring termination accepting;";l 118 AWG wires
external weatherproof backbox. See the Backboxes, Plates and
Gaskets Table on page three of this document for a summarization at each terminal
of these mounting options and the required accessories. The series RSSWP,ASWP,AH-24WP,MTWP-2475W,and MT-12/24 have UL/
ULC approval down to-40°F. The ET-1010 and ET70WP have UL approval down
to-40°F. The AH-12WP has UL approval down to-31°F.
uL Ew. U: FM
®
MEA APPROVED
E5946 151-92-E 7125-0785:131(ASWP)
S5391 7125-0785:146(ET70WP)
S2652 7125-0785:156(MTWP)
7300-0785:154(RSSWP)
NOTE:All CAUTIONS and WARNINGS are identified by the symbol B.All warnings are printed in bold capital letters.
,A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR
APPLYING THIS PRODUCT. VISIT WWW.000PERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INS IALLATION INSTRUCTIONS.
FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR
OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU
AND/OR OTHERS.
General Notes:
• Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range.
• All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table.
Wall Mount Ceiling Mount Wall or Ceiling Mount
�r
RSSWP MTWP
RSSWP MTWP on
MT AH
ASWP ET70WP ASWP ET70WP ET-1010 #
Strobe Order Code Strobe Order Code
RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 Audible Order Code
RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-24WP-R Red 7416
RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 AH-12WP-R Red 7415
RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWWhite 5187
Horn
Audible Strobe Audible Strobe MT-1 2/24-R Red 5023
ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251
ASWP-24MCWH-FR Red 5137 ASWP-2475C-FW White 4502 Speaker
ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 ET-1010-R Red 3135
Multi-tone Strobe
ASWP-24MCCH-FW White 5157 ET-1010-W White 3137
MTWP-2475W-FR Red 8420 Multi-tone Strobe UL Max.Current AH
MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457
MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 t24VDC 12 VDC
MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 High(99)dBA 0.192
Speaker Strobe MTWP-24MCCH-FW White 5122 Med(95)dBA 0.108
ET70WP-2475W-FR Red 9077 Speaker Strobe Low(90)dBA 0.058
ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452
ET70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 UL Reverberant dBA @ 10 Feet
ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 alts 1/8 1/4 1/21 2 4 8
W
ET70P-24135W-FR Red 4872 ET70WP-24177C-FW White 4859
ET70WP-24135W-FW White 4875 ET70WP-24115C-FR Red 4550 ET-1010 77 80 83 86 87 92 94
ET70WP-24115C-FW White 4732 ET70WP 78 81 84 87 90 93 95
Candela Ratings
• RSS,ET70WP and
f638 UL 638 ASWP
i6iiixiosp UL 1971+ 1 MTWP UL Max Current Model Number Agency Approvals
• 77°F @e-49�: • Strobe Only) High Med Low
ZJVY• 30*0• :00 g0 115. e 0.138 0.168 0.155 0.150 Strobe UL MEA CSFM FM BFP
RSSWP-2475 X X X X -
475C• 15 180 0.138 0.168 0.155 0.150 RSSWP-24MCWH X X - -
• 135 • 4:5 •96'• 0.300 0.355 0.340 0.335 RSSWP-24MCCH X X
MC60" 185 ' 185 f/� 0.420 0.480 0.465 0.460 Audible Strobe
••
115• •11P5 •47 • 0.300 0.355 0.340 0.335 ASWP-2475 X X X X X
• ASWP-MCWH X - X - -
• 177 177 97*10• 0.420 0.480 0.465 0.460 ASWP-MCCH X - X - -
1,�5� 185 . 1&5 V7• ; 0.420 **Wall mount rating only Multitone Strobe
X24177 • 177 'r'1 7 78 • 0.420 MTWP-2475 X X X X
MTWP-MCWH X X
UL Max.Curren K0T /MT MT MTWP-MCCH X X -
Audible) 'La VDC 12 VDC Homs/Audibles
BA HI STD HI STD AH-24WP X X X X X
Horn 0.108 0.044 0.177 0.034 AH-12WP X X X X X
Bell 0.053 0.024 0.095 0.020 MT-12/24 X X X X X
March Time 0.104 0.038 0.142 0.034 Speaker Strobe
Code 3 Horn 0.091 0.035 0.142 0.034 ET70WP-2475 X - X X -
Code 3 Tone 0.075 0.035 0.105 0.021 ET70WP-185 X - X X -
Slow Whoop 0.098 0.037 10.142 0.035 ET70WP-177 X - X X -
Siren 0.104 0.036 0.152 0.030 ET70WP-115 X - X X -
Hi/Lo 0.057 0.025 0.114 0.026 ET70WP-135 X - X X -
Mounting Accessories
3
WFP WFPA 10B WPSBB WPBB WBB
Gasket Kit Order Code
WP-KIT 4486
Mounting Options: Backboxes,Plates,Gasket Kits
Flush Plates
WFPA-R Red 4698 Surface Mount Flush
WFPA-W White 4701 Exposed Conduit Concealed Conduit Mount
WFP-R Red 4696
WFP-W White 4697 RSSWP Strobes WPSBB WPSBB+WP-KIT WFP
Backboxes ET70WP Speaker Strobes 10B 106+WP-KIT WFP
10B-R* Red 5046 ASWP Horn Strobes WPBB WPBB+WP-KIT WFPA
IOB-W* White 5047
WPSBB-R* Red 9751 AHWP Homs WBB WFP
WPSBB-W* White 3033 ET-1010 Speakers WBB - WFP
WPBB-R* Red 9014
WPBB-W* White 4692 MTWP Multitone Horn Strobes 10B 1013+WP-KIT WFP
WBB-R Red 2959 Multitone Horn 106 106+WP-KIT WFP
WBB-W White 2960
*106,WPSBB and WPBB models include weep holes and plug in the event that
moisture may have entered the appliance
SERIES MTWP APPLIANCES SYNCHRONIZED STROBE
Wiring Diagrams OPERATION WITH CODED FACP MTWP
m 0
o/ StrStrbe
out
be
SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE Syne
IN UNISON.RED AND BLACK SHUNT-WIRES ARE SUPPLIED. NAC., Module
or
PS Audible
FROM TO NEXT pre' � Circuit
PRECEDING + + APPLIANCE FACP Supply
APPLIANCE RED
- BLACK - OR EOLR
OR FACP NAC#2 ••••
Note: Strpbe ci cuit regGijq%gdhstant W911W,
SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED /•
STROBE AUDIBLE DSM MODULE SINGLE CLA•SsVA"NAC blAdUIT """
......
SERIES RSSWP,ASWP,AHWP,MTWP AND MT-12/24 STROBE � • :�• �• • •
NAC SYNC • • •• •••••
APPLIANCES CIRCUIT •• • •• . • •••
FROM TO NEXT OUT +our1
PRECEDING + ± APPLIANCE 0+IN16• • ST ' ';'
•
APPLIANCE OR OR EOLR MINU♦1 • WP "5• • 000
FACP FACP + UDIBLE ••••••
9 •
• . 04 •••
MINUS 2r.• • * *00
•0 / •
+ — +IN 2 RSS ••"swT ST
STROBE
NAC +Quiz
CIRCUIT
RETURN
Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery.
#Refer to Data Sheet S7000 for Mounting Options
NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance
with Cooper Wheelock Inc.dba Cooper Notification standard terms and conditions.
ARCHITECTS AND ENGINEERS SPECIFICATIONS
General
Weatherproof notification appliances shall be UL listed for outdoor use.Weatherproof Strobe appliances shall be I�isted under UL Standard
1638(Standard for Visual Signaling Appliances)for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices
for Hearing Impaired).The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using
either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock
mounting accessories.
Weatherproof Strobes
Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range
of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings
up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available.The
strobes shall operate over an extended temperature range of—40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of
95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm
Control Panel(FACP).
Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor
use under UL Standard 464.The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized.
The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC.
Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings.Multitone
Audible/Strobe combinations shall have independent inputs for the audible and strobe.The strobes shall be able to be synchronized.
The audibles shall be able to be coded when operated on a separate NAC.
Weatherproof Speakers and Speaker/Strobes
Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480.All speakers shall provide
field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back
construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010.They shall be
listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series
ET70WP.They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA.
Synchronization Modules
When synchronization of strobes or temporal code-3 audibles is required,the appliances shall be compatible with the Wheelock Series
DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The
strobes and audibles shall not drift out of synchronization at any time during operation.
Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required.
The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a
separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC.
Weatherproof Mounting Accessories
Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings.Surface mounted appliances
shall mount to Wheelock 106, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit.
For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a
weatherproof seal for the electrical box.Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP
or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance.
...... .... e .
e e e e
ee ee
e e e e
ee..ee eeee .ee.ee
e
e e e ee..e.
..eeee
e ee eee.
e e e e
.eeee ee . eeee
e e
.eeee a ee ..eeee
e e e e 0000 ee . e. e.
e
e e e...ee
. e e
e e e
ee.e
e e
IVE ENLOURMI AND SU41011Is NICET CERTIFICATION
3 YEAR WARf2AN-"
S9004 WP 11/12
NJ Location
273 Branchport Ave.
Long Branch, NJ 07740
800-631-2148
Cooper Notification is Wheelock*® SAFEPATH' WAV
rc� COOPER Notification
SYS TEM
�45 SEJ V.SOR'q
,
Photoelectric '
Smoke Detectors
System Sensor i3-series smoke detectors represent
f,s
significant advancement in conventional detection.
The i3 family is founded on three principles:installation TM
ease,intelligence,and instant inspection.
Features Installation ease.The i3 line redefines installation ease with its
Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included
with heads).The large wire entry port and in-line terminals provide
Large wire entry port ample room for neatly routing the wiring inside the base.The base
In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as
Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3
boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action.
Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features
Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and
Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize
nuisance alarms.2-wire i3 detectors can generate a rernvtc•KD-
indicated maintenance and smoothing algorithms indicated maintenance signal when cbnn�%d to the#10/0OD2 ••••••
Simplified sensitivity measurement loop test/maintenance module or a p^N equipped:its tl,i3 •
Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless dcg","?plays theSi!rtsftivityof i3****••
detectors in terms of percent-per-fool IM lation. • •
••.•..
•Loop testing via EZ Walk feature ••.. .. . • • �
Built-in test switch Instant inspection.The i3 series provides wide-angle reM Ind ••;••.
green LED indicators for instant inspection Nthe deVt&r's. 00000••0•
condition:normal standby,out-of-sensitivity,alarm,or freeze trouble.•••0;0
When connected to the 2W-MOD2 loop Ost7maintenance module ••
• 0 •. 000000
ora panel with the i3 protocol,the EZ Walk loop test 1'eetsl"*s
available on 2-wire i3 detectors.This;atuvcrifies the initiating loop••0•:
�
wiring by providing LED status indication at each detuceto p• • •
Agency Listings
F M MEA MSFM �(ET�
LISTED APPP ED approved approved \,��us
5911 3011446 7272-1653.152 290-01-E 2093 3180932
Ci)3 Smoke Detector Specifications
Smoke detector shall be a System Sensor i'Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The
detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F
(57.2'C).The detector shall include a mounting base for mounting to 3'/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster
ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the
base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The
detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual-
color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used
in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel
and shall provide a loop testing capability to verify the circuit without testing each detector individually.
Electrical Specifications
Operating Voltage Nominal: 12/24 V non-polarized
Minimum: 8.5V
Maximum:35V
Maximum Ripple Voltage 30%peak to peak of applied voltage
Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average
Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V
Peak Standby Current 2-wire:100 NA;4-wire:n/a
Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC
Physical Specifications
Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height
Weight 6.3 oz(178 g)
Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100'1`(0°C to 37.8°C)
Operating Humidity Range 0 to 95%RH non-condensing
Thermal Sensor 135°F(57.2°C)fixed
Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C)
Sensitivity 2.5%/ft nominal
Input Terminals 14 to 22 AWG
Mounting 3'/2-inch octagonal back box
4-inch octagonal back box
Single-gang back box
4-inch square back box with a plaster ring
Direct mount to ceiling
LED
LED Mode Green LED Red LED Condition Duration
Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds
Normal(standby) Blink every 5 seconds off
Out of sgr"i�ty off Blink every 5 seconds
•••••• Freezcpti4w,• of f • Blink every 10 seconds
•• Alarm •• • pff••. Solid
•0000• 0•0
0
0
60.•600
0•••:OrderingInformation
.000 hermal Wiring Alarm Curniint
• • 2W-B CG•••0 2-wire 130 mA max.limited by control panel
60.60•• . 6060
0:00#0 2WT-B•••• : %0••• 2-wire 130 mA max.limited by control panel
• 4W-B • W0•••• 4-wire 20 mA @ 12 V,23 mA @ 24 V
• 4WT-B
•60••60• 6 • s • 4-wire 20mA@12 V,23mA@24V
6060.•
• 60 Accessnroes•••• • •
6060••••
• • 2W-MpDA. • }wii test/maintenance module RT Removal/replacement tool
SENS R •• Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter
STEM 82009 5Yz«m s sa,
3825 Ohio Avenue•St.Charles,IL 60174 r'<nd�a�Pen�e�al�nnz,�nleam�na_9 w,�nrnrtnnnce 2,s,ts,-s«ms.n,n,core
n,
.SENSOR Phone:800-SENSOR2•Fax:630-377-6495 cerenl pindu«nrori including The latest wisbn of his data heel.
.a05-0318-007•:/07--2169
COO RNotification
Series MIZ Mini Horn Appliances
ii
SERIES MIZ
Description: Features:
Wheelock Series MIZ piezoelectric Mini Horns are compact Approvals include: UL Standard 464, California State Fire
electronic alarm appliances that are listed under UL Marshal(CSFM),New York City(MEA),and Factory Mutual
Standard 464 for Audible Appliances in Public Mode Fire (FM)
Protection Systems. The Series MIZ-24S models provide Field selectable settings for Temporal(Code 3)or Continu
a field selectable Continuous or Code 3 horn tone when ous Horn
connected directly to a fire alarm control panel. They Synchronized code 3 horn when used with Wheelock Sync
can also provide a synchronized code 3 horn tone using Module
the Wheelock DSM Sync Modules or Wheelock Power Designed to meet or exceed NFPA/ANSI standards
Supplies. The series MIZ appliances are attractive, offer Convenient mounting to any standard single-gang box
high sound output along with low current draw and are Beauty plugs to cover mounting screws
ideal for alarm signaling in individual rooms, apartments, No additional trimplate required for flush mounting
hotels,motels and offices.Color choices of red or off-white
will blend with any decor. Fast installation with In/Out screw terminals using#12 to
#18 AWG
• High sound output with low current draw
•
Wiring Diagrams (for all models) Available in red or off-white color
4.000
FROM
• • 4.4.4.4. 4.4.4.4.••
PRECEDING + + TO NEXT Applications: • • • •
APPLIANCE - - APPLIANCE Individual Rooms 00 0 + •00• #•
•4.4.4.4.• 0000 000000
OR FACP OR EOLR Apartments 600:00 0
• Hotels ••••••
4.4.4.4. 4.• • •
• Motels •����• ; •�4.• �����
+ - Offices • •
•4..•4.• •4. • ••.4.•
.. 4.4. . .. .••...
4..4.4..0 •
. . 4. 4. .4..4.4..
Specifications and Ordering Information • • + •
• • 4. ••4.4.4.4.
Order Mounting Agency Approvals •4. • ;
Model Code Description Options
** UL MEA CSFM FM
MIZ-24S-R 8485 24 Volt, Red B X X X X
**Refer to Data Sheet S7000
MIZ-24S-W 8484 24 Volt, White B X X X X for Mounting Options.
General Notes:
• Mini Horn models are Listed for indoor use with a temperature range of
32°F to 120°F(0°C to 490 C)and maximum humidity of 93% RH±2%.
UffY 'OF FM •Rated Input voltage(eitherfiltered DC or unfiltered full-wave-rectified FWR):
MEA APPROVED 16-33 VDC(for 24 VDC MIZ-24S models)
S5391 151-92-E 71250785:161
Architects and Engineers Specifications
The notification appliance shall be a Wheelock MIZ-24S audible appliance or approved equal. The Notific ion Appliance shall be
electronic and shall have field selectable settings for Temporal (Code 3) or continuous horn and support co led systems operation.
The anechoic sound pressure measurement on Temporal(Code 3)setting shall be 87 dBA minimum at 24VD 33. The anechoic sound
pressure measurement on Continuous Horn setting shall be 87 dBA minimum at 24 VDC. Operating voltages shall be 24 VDC
using filtered power or unfiltered power supply(full-wave-rectified). All models shall have provision for standard reverse polarity type
supervision and IN/OUT wiring using terminals that accept#12 to#18 AWG wiring. The appliances shall be mounted indoors and
mount on standard single-gang electrical backboxes requiring no additional trimplates or adapters.
Table 1: UL Listed Models and Ranges ' RMS current ratings are per
UL average RMS method.
Reverberant dBA Anechoic dBA UL max current rating is the
Average Per UL 464 @ 10 ft @ 10 ft maximum RMS current within
Regulated RMS Mounting the listed voltage range(16-33v
Model to Current' Options for 24v units For strobes the
Voltage (AMPS) Continuous Code 3 Continuous Code 3 pons UL max current is usually at the
dBA dBA dBA dBA minimum listed voltage(16v for
24v units). For audibles the
24 VDC 0.025 83.2 78.8 87.9 87.9 B max current is usually at the
maximum listed voltage (33v
MIZ-24S for 24v units). For unfiltered
UL max* 0.026 85.8 81.3 90.6 89.7 B FWR ratings, see installation
instructions.
NOTE: All CAUTIONS and WARNINGS are identified by the symbol. All warnings are printed in bold capital letters.
AWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY
BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,
CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE
PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR
DEATH TO YOU AND/OR OTHERS.
A WARNING:CONTACT WHEELOCK FOR THE CURRENT"INSTALLATION INSTRUCTIONS"(P84408)AND"GENERAL
INFORMATION"SHEET(P82380)ON THESE PRODUCTS.THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS
IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT
INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS,INCLUDING:
•TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES.
•FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE
CIRCUITS.
•THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED VOLTAGE RANGE.
•FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN
IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,
WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS.
•CONDUCTOR SIZE(AWG),LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND
INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS.
Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated,
maintained ag(ttptrationally tested in accordance with their installation instructions at the time of installation and at least twice a
*,�ee*e'more oftenend in acabirdarste with local, state and federal codes, regulations and laws. Specification, application, installation,
operation, maintenance and tes*ig must be performed by qualified personnel for proper operation in accordance with all of the latest
.ULwal Fire Prrifaotion Assoaation(NFPA), Underwriters'Laboratories(UL), National Electrical Code(NEC),Occupational Safety and
J-lealth,4dministration(OSH4),Uale state,county,province,district,federal and other applicable building and fire standards,guidelines,
7eg6Ie1ons, laws ar"codes ipglyding, but not limited to, all appendices and amendments and the requirements of the local authority
havinV jurisdicltipU JAMJ). •����•
NtTR:•Due tgeogthduous 4&48#ment of our products,specifications and offerings are subject to change without notice in
et eertiMence wilts WMelock Ifit.Mndard terms and conditions.
WE ENCOURA*G**EVD SUPPORT NICET CERTIFICATION
3 YEAR WARRANTY
S1700 MIZ 06/11
NJ Location
273 Branchport Ave,
Long Branch,NJ 07740
P:800-631 2148
F:732-222-8707
Cooper Notification is Wheelock"® SAFEPATH' wnv COOPER Notification
File No:S24065 CCN: UUFX
Service Center No: 1
r Expires:05/14/2016
U L Issued:05/15/2015
CENTRAL STATION - FIRE
FIRE ALARM SYSTEM CERTIFICATE
(NFPA 72)
THIS CERTIFIES that the Alarm Service Company is included by UL LLC in its Directory as qualified to use the UL Listing Mark in
connection with the certificated Alarm System.This Certificate is the Alarm Service Companys representation that the Alarm System
including all connecting wiring and equipment has been installed and will be maintained in compliance with requirements established
by UL.This Certificate does not apply in any way to the installation of any additional signaling systems,such as;fire,smoke,waterflow,
burglary, holdup, medical emergency, or otherwise,that may be connected to or installed along with the Certificated Alarm System.
This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors
signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate.
LIMITATION OF LIABILITY: UL LLC makes no representations or warranties,express or implied,that the Alarm System will in all
cases prevent any loss by fire,smoke,water damage, burglary, hold-up or otherwise, or that the Alarm System will in all cases provide
the protection for which it is installed or intended. By the Alarm Service Company providing this Certificate and the Protected Property
acceptance of this Certificate,the Alarm Service Company and the Protected Property acknowledge and agree that UL does not
assume or undertake to discharge any liability of the Alarm Service Company or any other party. UL is not an insurer and assumes no
liability which may result directly or indirectly from inspection of the equipment,failure of the equipment,failure to conduct inspections,
incorrect certification, nonconformity with requirements,failure to discover nonconformity with requirements,cancellation of the
Certificate or withdrawal of the Alarm Service Company from inclusion in ULs Directory prior to the expiration date appearing on this
Certificate.
OPERATIONAL REQUIREMENTS:The Alarm Service Company bears the responsibility for the correctness of the installation;
maintenance of the system documentation;periodic system inspection and testing; maintaining and providing any necessary repairs.
All operations and maintenance shall be conducted in the manner prescribed by the NFPA standard referenced. All required service
is to be provided for in an appropriate contract. System documentation is defined to include any"As Built Drawings";the records of
any"Acceptance Testing"; and the records of all periodic system testing and maintenance.
SYSTEM DESCRIPTION:This system is installed and operated in accordance with standard NFPA 72,2002 edition.
Area Covered:BUILDING
Authority Having Jurisdiction:Miami Dade Fire Rescue Department
Responding Fire Department:MIAMI DADE FIRE RESCUE
SYSTEM DEVIATIONS FROM REFERENCED NFPA STANDARDS
NONE
Protected Property: Alarm Service Company:
BARRY UNIVERSITY BROWNE HALL CHI ALARMS INC.
11300 NE 2 AVE • • 14070 NW 82ND AVE
MIAMI SHORES,FL 3316 •• ••: . . . • • • MIAMI LAKES FL 33016-1547
. •. . • • • •.• .
. . • • • . .. . •
SN: FC5593730 ;•
... . . . ... . .
File No: S24065 CCN: UUFX
Service Center No: 1
Expires: 05/14/2016
U L
Issued:05/15/2015
Entry No:5332607 Version:7
CENTRAL STATION - FIRE
FIRE ALARM SYSTEM CERTIFICATE DESCRIPTION
FOR Certificate Serial No: FC55937389
Protected Property: Alarm Service Company.
BARRY UNIVERSITY BROWNE HALL CHI ALARMS INC.
11300 NE 2 AVE 14070 NW 82ND AVE
MIAMI SHORES,FL 33161 MIAMI LAKES FL 33016-1547
Comments and Clarifications:
AS REQUIRED BY LOCAL JURISDICTION
System Description:
Area Covered: BUILDING
Authority Having Jurisdiction: Miami Dade Fire Rescue Department
Responding Fire Department: MIAMI DADE FIRE RESCUE
Testing and Maintenance Contract date: 07/15/2014
SYSTEM DEVIATIONS FROM REFERENCED NFPA STANDARDS
NONE
Automatic Fire Detection and Alarm Service
Coverage is Selected Area
2 -Smoke Detectors : 0-Ionization 2-Photoelectric
Manual Fire Alarm and Guard's Tour Supervisory Service
6 -Manual Fire Alarm Boxes
Alarm Notification and Annunciation Devices
8-Visual Signals : Type-Strobe
48 - Horns
6-Audible/Visual Signals : Type-Strobe
Control and Transmitter Unit
MIRCOM SECUTRON 2312, DSC 3G3070,SECUTRON 2312
Remote Monitoring
UL Listed Central Station
File: S2623, Service Center Number: 0
CENTRALALARM CONTROL INC
13973 SW 140TH ST
MIAMI FL 33186-552p•• ••; ••. ;
Alarm Retransmission tFie� artmorrt••
Public Telephone Netwbrk antPPublic•fetel one Network
Alarm Transmission Method: Cellular Digital Alarm Communicator
*00 000 see
.. . . . . . . . . .
So: .. see 000
fit . ... .
. . . . . . . . . .
. .. .. . . . .. ..
...
0 0 0 ... . .
Miami-Dade Fire Rescue
Fire Alarm Pre-Submittal Checklist MIAMI.[aADE
Based On NFPA 72 2007'Ed.&NFPA 1 and 1012009'Ed.
e
Building Dept.Pro ess Number is(Begins with C gr M): Date:
1 Project Name: / is provided in title block of plans. YES NO N/A
2 Address in title block shal!,,ilihatch address in"Buif ng Dept.Computer System"and attached permit application.If address contains
a specific building,floor,4bite,or unit number or letter,it shall be provided in title block,to match BuildingDept.Computer System.
3 The total cost of the installation to the customer is$ 15ya 6-P and a copy of the contract or a notarized affidavit
from the owner showing this amount is attached.
4 Fire Alarm Systems costing more than$5,000 are sealed or stamped by a Florida Registered Professional Engineer.
5 The total number of DEVICES and COMPONENTS being installed is
6 The alarm qualifiers state license number is EC EH EY # and a copy is attached to plans.
7 Complete,current manufacturer's Specification and Installation sheets are attached for all control units,components,devices,
modules and relays listed on Legend.
8 Is this permit application for fire alarm work a result of a Notice Of Violation(NOV)issued by Miami-Dade Fire Rescue?If yes,a
copy of the Notice of Vi lation is attached.
9 This fire alarm: is required under (fill in the Occupancy Chapter&Section from NFPA 101
OR,U is a life safety equivalency OR,U is a non-required system or component.
This is an"EXISTING(Local)Fire Alarm System"and is stated as such on the plans.AHJ will require documentation of prior
10 approval of system as a(Local)Fire Alarm System in the form of the original Fire Dept.approved job copy set of fire alarm plans or
certified microfilm copy of same.
11 This is a"NEW Local Fire Alarm System"and is stated as such on plans.
This is an"EXISTING Central Station Service Fire Alarm System"and is stated as such on the Plans.A copy of the existing
12 BUILDING UL or ETL certificate,or FM Placard,specifically identifying this protected premise by address,and uniquely identifying 61-1
this building's fire alarms stem,is attached.
If the company that issued the existing certificate or placard for this building's fire alarm system is different than the company
13 applying for this permit;is the required Affidavit to Work on another Company's Certificated or Placarded Fire Alarm System
Provided?
14 This is a NEW Certificated of Placarded "Central Station Service Fire Alarm System"and stated as such on the plans.
15 If this is a NEW"Central Station Service Fire Alarm System,"a copy of the UL or ETL certificate of FM placard from the contractor,
or from the Central Station Service Company,issuing the building certificate/placard,is attached.
This is an"EXISTING Remote Supervising Station Fire Alarm System"and is stated as such on the plans.AHJ will require
16 documentation of prior approval of system as a Remote Supervising Station Fire Alarm System in the form of the original Fire Dept.
approved job copy set of fire alarm plans or certified microfilm copy of same.
17 This is an"EXISTING"Sprinkler Waterflow and Supervisory System"only and is stated as such on plans.
This is a NEW"Sprinkler Waterflow and Supervisory System"only and is stated as such on plans.The system is monitored off-site
18 and provides emergency forces notification through a Certificated(_)or Placarded(_)"Central Station Service Fire Alarm"and
is stated as such on the plans.
A complete detailed statement of the"SCOPE OF WORK"is stated on the plan.Please note that the complete tenant space,in its
19' entirety,will be inspected for compliance with NFPA 72(2007)and NFPA 101 (2009),or prior editions of these codes if applicable.
Also outline scope of work with bolded dashed lines floor Ian and riser for existingsystems.
20 The buildingis"New" or"Existing" and is indicated as such on the plans.
21 A description of the building is provided,including fire sprinkler systems,fire suppression systems,number of stories,square
footage per floor,and elevation of the last occupied floor if over 5 stories.
22 A location Key is provided showing the area of proposed work within the building.Also provided is a site key for projects with
multiple buildings showing locations of all buildings with addresses
23 All interconnected Fire Alarm Control Panels are arranged to function as a single sstem and monitored for integrity er NFPA 72.
24 The class/style is shown for all Initiating Device Circuits(IDC),Signal Line Circuits SLC and Notification Appliance Circuits(NAC).
25 The maximum number of each device type is provided for each IDC based on device load or each SLC,based on class and style,
per NFPA 72 and the manufacturer's specifications.
26 A specific"Sequence of Operation"including all alarm,supervisory,trouble and control functions such as fire sprinkler,door
release,smoke control,elevator recall,suppression systems,and transmission of signals offsite,etc.arespecified on the Ian.
27 The type of monitoring station,(Listed Central Station,Remote Supervising Station,Listed Proprietary Supervising Station),where
alarm,trouble,and supervisory signals are transmitted to,is clearly and concisely stated in the"Sequence of Operations"
28 The method of communication to the monitoring station is included on the riser.
29 If this building contains elevators that are not capable of recall,it shall be stated as such on plans and written documentation on 0.
elevator contractor's letterhead statin that"Elevators are not capable of providing recall function",is provid2d,
30 If this building does not contairld firgdVrr9 slisteni,and the fire alarm panel is used exclusively for elevator recall;plans shall
clearly designated panel as"Irlevator Recall o ro a iso Panel"
31 Manufacturer,model number cvd unique ayinboWomeaelt�odel number is provided for each device,module,relay,component,
ower supply and fire alarm o Rol el% e(lf od i thQ s bol legend.
32 Each device,module,appliance and component is identified with its own unique number and indicated on the floor plans and riser.
33 Floor plans are drawn to 1/8"scale or,if using another scale,all device coverage is diagrammed on the floor plan and all room
dimensions are included. • ••• ••• ••• •• •••
Designed by: ••• • • • • • Phone#:
Signature: Created by: MDFR 08/2012
••T4HIS IS A REQUf l2U,5O§UMEPT ON ALL FIRE ALARM PLAN SUBMITTALS
• • • • • • 10F2
. .. .. . . . .. ..
... . . . ... . .
Miami-Dade Fire Rescue
Fire Alarm Pre-Submittal Checklist MIAMI.D�ADE
Based On NFPA 72 2007'Ed.&NFPA 1 and 101 2009'Ed.
r
34 All rooms&spaces are labeled indicating their use,and the occupant load has been provided for all assembly use rooms with an
occupant load of 50 or greater.
35 All new,existing,replaced or relocated devices are indicated on the floor plans and a complete riser diagram showing all new and
existing devices of the entire fire alarms stem is provided.
36 Ceiling type and height is provided for all ceiling mounted devices.
37 All devices and components located in areas in which the voltage,temperature,and humidity variations exceed those conditions
stated in NFPA 72,are listed for conditions and all such areas are identified.
38 A note is provided on the plans stating"Room containing FACP,Booster Power Supply,Voice Evacuation and Amplifier panel(s),
Dialer,or Radio is mechanical) ventilated",as applicable.
39 The FACP or Remote Annunciator and as applicable EVAC panel or Remote Microphone is located at the main entrance/lobby in
single tenant buildings,or in a common area main entrance/lobby of a multi-tenant building.
40 The FACP,Communicators,Amplifiers,NAC Panels and all sub-panels are protected with a smoke detector.
41 If a complete automatically activated system,not less than one manual fire alarm pull box shall be provided to initiate system.The
pull box shall be located where AHJ specifies.
42 If a manually activated system,the travel distance to reach a pull station is less than 200'feet and within 5'feet of all required floor
and/or building exits.
43 All automatic initiating devices are shown and are located in accordance with NFPA 72,the manufacturer's specifications,and
accepted engine rinractices.
44 Area smoke detectors,if used,shall provide coverage throughout the entire smoke compartment.
45 All visual notification appliances are placed per tables in NFPA 72 and each strobe has its candela rating on the floor plan and riser.
46 All corridor spaced strobes are placed a maximum of 100'feet apart and within 15'feet from the ends of the corridor.
47 All spaces throughout the entire building shall meet the audible characteristics of NFPA 72 and NFPA 101.
48 Bell used for water flow annunciation is shown on floor plan,riser and legend.Bell shall be located so as to be visible and heard
from roadway or parking area within close proximity to Fire Dept.Connection(FDC).
Flow Bell sequence of operations shall state as follows:
49 A)Flow bell shall activate upon water flow only. U-1 oll
B)Flow bell shall continue to sound as long as water is flowing.
C FACP shall not be capable of silencing Flow Bell.
50 The location of Backflow Preventer(BFP),Post Indicating Valve(PIV)and Fire Dept.Connection(FDC)are indicated on the floor
tans,riser and legend forsprinkled buildings.
51 Walls,partitions,racks,shelves and equipment that do not extend to ceiling,are shown with their heights indicated on floor plan.
Duct detectors or relays for duct detectors are shown on the floor plan and riser for all systems greater than 2000 CFM supply or
52 greater than 15,000 CFM return.Duct detectors shall derive their 24 volt do power source from the Fire Alarm System to satisfy the
monitoring for integrity requirements of NFPA 72.4.4.7,for devices and conductors.Please show compliance on riser.
53 A complete system riser diagram is provided showing each floor of the building with all zones and circuits labeled.
54 The conductor size,type,and quantity are provided for each circuit on riser.
The fire pump is monitored for:A)Pump or Motor Running,B)Loss of phase,C)Phase reversal,and,if applicable,D)Controller
55 connected to an alternate source;and are indicated at U a continuously manned location,or U the supervised fire alarm (�
system.
56 Show all relays on floor plan and clarify function on riser.(Sprinkler,Wet Chem.,Dry Chem.,Clean Agent,Foam,Elevator Shunt-
Trip,Music Shut-Down,Door Release and other building control functions.
57 The AMPACITY of each Power Supply and Notification Appliance Circuit is specified for each FACP&Power Supply Panel on
tans.In addition,the individual device current is specified on riser for each notification appliance Homs/Speakers/Strobes).
58 The total"ACTUAL"footage to the last device along with voltage drop calculations are provided on plans for each NAC for each
ower supply.
59 The wattage tap is indicated for all speakers.
60 The wattage capacity and load is provided for each amplifier.
All load values for"STANDBY"&"ALARM"used in calculations are high-lighted on the manufacturer's specification or installation
61 sheets.Also,AMPACITY of equipment/components and circuits are high-lighted on manufacturer's sheets.
62 This system includes Emergency Voice Evacuation and is provided with 15 minutes of secondary alarm power.Required in all high
rises and assembly occupancies with an occupant load greater than 300.
63 This system is being provided back up power by an emergency generator and will provide 4 hours of standby power plus the
appropriate seconds alarm power.
64 Battery calculations,detailed in chart form,showing all information required per NFPA 72.4.4.1.5.3.1 are provided on plans for each
back-up ower supply.
The replacement of the Fire A W Control Panel with anythineNher than the exact same make and model number panel;or the
65 addition of a Fire Alarm Cont�I Panel f hi%jill arojtid�or replace any of the functions of the existing FACP,shall require the fire
alarm system to I up-grade o curro mt codeestlndprdl,•or cft of Miami-Dade County,Part III,Chapter 14,Article III,Section
14-66 9 & 10 • •• • • • ••
66 If the scope of work includes greater than one-half of the entire fire alarm system's devices,then the entire fire alarm system shall
be up-graded to current code standards,per code of Miami-Dade County,Part III,Chapter 14,Article lll,Section 14-66(9).
• ••• ••• ••• •• •
• • • • •• • •
•• • • • • • • • • •
Designed b ••: :• ••• ••• ••• •••
9 Y� Phone#:
Signature: Created by: MDFR 08/2012
••ABIs IS A RE40UORE ROJUMEIT ON ALL FIRE ALARM PLAN SUBMITTALS
• • • • • •