ELC-15-2402 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-243943 Permit Number: ELC-9-15-2402 Scheduled Inspection Date: September 25, 2015 Permit Type: Electrical - Commercial Inspector: Devaney, Michael Inspection Type: Final Owner: , BARRY UNIVERSITY Work Classification: Addition/Alteration Job Address: 11300 NE 2 Avenue Browne Hall Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360010160-14 Project: BARRY UNIVERSITY Contractor: CHI ALARMS, INC. Phone: (305)827-2856 Building Department Comments FIRE ALARM SENSOR REPLACEMENT Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. September 24, 2015 For Inspections please call: (305)762-4949 Page 14 of 34 4,( � Y a\ Miami Shores Village yEtO 10050 N.E.2nd Avenue NE � � �� � Miami Shores,FL 33138-0000 ` OR Phone: Phone: (305)795 2204 N Expiration: 03122/2016 Project Address Parcel Number Applicant 11300 NE 2 Avenue Number: Browne Hall 1121360010160-14 Miami Shores, FL 33138-0000 Block: Lot: BARRY UNIVERSITY INC Owner Information Address Phone Cell BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractor(s) Phone Cell Phone Valuation: $ 2,500.00 CHI ALARMS, INC. (305)827-2856 Total Sq Feet: 0 Type of Work:FIRE ALARM SENSOR REPLACEMENT Available Inspections: Additional Info:FIRE ALARM SENSOR REPLACEMENT Inspection Type: Classification:Commercial Final Scanning:3 Meter Box Alteration Relocation Fire Alarm Service Change Review Electrical Underground W.W. Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $1.80 DBPR Fee Invoice# ELC-9-15-57162 $2.25 09/22/2015 Credit Card $50.00 $ 112.30 DCA Fee $2.25 Education Surcharge $0.60 09/24/2015 Credit Card $ 112.30 $0.00 Permit Fee $150.00 Scanning Fee $3.00 Technology Fee $2.40 Total: $162.30 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accu[ at all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above-named coat r do the work stated. September 24, 2015 Authorized Signature:Owner / Applicant / Co / Agent Date Building Department Copy September 24,2015 1 4 o Miami Shores Village SEP 2 , Building Department BY: _ 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 -- ' Tel:(305)795-2204 Fax:(305)756-8972 /� INSPECTION LINE PHONE NUMBER:(305)762-4949 j_ 1 FBC 201c BUILDING Master Permit No. SLC (5— 2NO Z PERMIT APPLICATION Sub Permit No. ❑BUILDING 54ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL OPLIBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR , I ,{DRAWINGS LL JOB ADDRESS: l t 3�� '� = -� �RO � (,�'l� � 334 Citv: Miami Shores County: Miami Dade Zip: 3--y("4 Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): A ✓ i e-,S Phone#: Address: /t/3� Mc Z-^ n AlV City: /�'�F�Hti+' �Y� State: Zip: 3 l G Tenant/Lessee Name: Phone#: _� _ 1��4 — 3 Z Email: S4a'yip-p CONTRACTOR:Company Name: �� /���J -Tor, Phone#: r3 eL)7 Address: 1:�0 70 8 Z City: Ml �� .�P� State: ��, Zip: Qualifier Name: '40—-e"(f �i Phone#: 78(, ��7 Y7 7 State Certification or Registration#: 4� Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ off, `J��• Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: ft R-E A LN 19A SF.�JS 0 j2= REPLA G E µms/ E Specify color of color thru tile: Submittal Fee$ "'" Permit Fee$ 1;4 00 CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ I I !, ' a (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address _ City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after th9lbuilding permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will b harged. Signature Signature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of�_ 7 20 1� ,by l U '' lav of who is personally known to _,A.e �t.� jb�is!p:e�rsonally known to,;' me or who has produced %%0._�ffkftw. as me or who has produced as identification and wh id tai identification and who did take an oath. NOTARY PUBLIC: $ ;�►, �- i. % NOTARY PUBLIC: Si Sign: OQ PrinPrint• !� ••' �� N D • ti/%/ I�I������N� a EXPIRES:December 1,2016 Seal: Seal: of F ' Bonded Thru Notary Public Undenvrltgrs APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) NOTE: A L H SETCM) U BE EVIEWED MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street(Coral Way) • Miami, Florida 33175-2474 • (786)315-2000 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE AND/OR ENVIRONMENTAL SERVICES PROVIDE MUNICIPAL PROCESS NUMBER HERE a Job Address DCS /�E7 ¢z Contractor No. ���9 7 � o z / o o Last four 4 di its of Qualifier No. i �G z W Folio �! a%3 C7 — C7OD on5c) � ( ) g o W a Q Contractor Name 141 r�S a o Lot Block F Qualifier Name �'`'� _ ' O a Subdivision PBpg zp LL J j 2 v z Address 1 c5"7 Metes and bounds City � ' State ruip3 0 . [ ] New Construction on [ ] Demolish F Vacant Land [ ] Shell Only Current use of property .r> i UerS i Uz [ '] VtpKkion Interior [ ] Addition Attached •Ej [ ] AR2ration Exterior. [ ] Addition Detached Description of Work • �s [ ]RsIaG$tion of 9tructa�•re [ ] Re-Roofliry� •. a [ ] ffr closure ; [ ] Foundation Only • ...... Sq. Ft.I goo Units � Floors— Re pai� [ ] Tent •... [ ]•Qepji?Due ts"rO• Value of Work o r-) - C3t� • . • ••• 00 •• [ ]•ve%l " N [ ] Chg. Contractor W Owner 1;orw 0-0 11'e 9t? •• Ll I. Oetegory F [ ] Re-Issue a Address • [ 1VII;r� ••:•.. [ ] ✓} Re-Stamp City State Zip ••.. [ ]•MIrP� :•,"• w [ ] Revision w Phone a [ -Mum w [ ] Not Applicable for 3 Last four(4)digits of [ ] FIRE ¢ Fire o Owner's Social Security No. N Name I Owner z o gv N w w Address Address z a w Y City 1 ti I State��Zip �d I l-� v Z City State_Zip 0.0X LU 3: Phone 2).C S (oo , _ G-7 -7 a Phone z 1 am requesting a Special Request Plan Review(SRI)to be scheduled as soon as possible at the rate of$209 for the first hour a g¢ and$71.50 per each additional hour in addition to the review fees. Minimum charge one-hour. Tj vam N w w 1 sl Request: Date: LL w 2nd Request: Date: 31d Request: Date: z 5 1 am requesting Optional Plan Review(OPR)to be scheduled as soon as possible at the rate of$75 for each discipline. 1L a Additional review fees may apply. z� 03:15t Request: Date: 0 W 2nd Request: Date: 9 31d Request: Date: 12301-192 4/14 i f BUILDING PERMIT CATEGORIES CATEGORY DESCRIPTION PERMIT TYPE BUILDING 01 GENERAL BUILDING-COMMERCIAL MBLD 02 SUB-GENERAL BUILDING-RESIDENTIAL MBLD 08 CANVAS AWNING MBLD 10 COMMUNICATION TOWER MBLD 15 DEMOLITION MBLD 29 METAL AWNING &STORM SHUTTER MBLD 48 SCREEN ENCLOSURES MBLD 55 SWIMMING POOL MBLD 56 TENNIS COURTS(SURFACE PAVING) MBLD 86 TRAILER TIE DOWN MBLD 88 WALK-IN COOLER MBLD 91 MARINAS MBLD 92 LOW SLOPE APPLICATIONS (GRAVEL, SMOOTH MODIFIED, SINGLE PLY) MBLD 95 SHINGLES(ASPHALT, FIBERGLASS) MBLf[S`;�; • 96 SHINGLES(METAL ROOFS/WOOD SHINGLES&SHAKE) ,". MBLD 97 STAGE 2 VAPOR RECOVERY SYSTEM MBLi7":0 :400*: 99 SOIL IMPROVEMENT ��•;�;MBLD . '. 0100 BULK STORAGE PROPANE TANK MBLD •• ""'• 0101 REMOVABLE STORM PANELS ..:.•:MBL®•, "�_'•• 0107 TILE ROOF ••••�MBLQ . 0110 WATER MAIN �•••• MBLD` •""` 0111 SITE PLAN ••':"MBLD•*,, .....• 0112 INDOOR EVENT/EXHIBIT •*6** MBLD. •..' •, ELECTRICAL '...•` li 04 FIRE ALARM SPECIALTY MELE 16 SPECIALTY WIRING MELE 38 GENERATORS MELE LPGX 01 LIQUEFIED PETROLEUM GAS MLPG 02 MISCELLANEOUS MLPG 04 LIQUEFIED PETROL. GAS/STATE MLPG MECHANICAL 09 ABOVE/BELOW GROUND TANKS/PUMPS &POLLUTANT STORAGE SYSTEM MMEC 38 COMMERCIAL HOODS MMEC 43 FIRE CHEMICAL MMEC 46 SPRAY BOOTHS MMEC 48 SMOKE CONTROL MMEC 52 RESIDENTIAL ELEVATOR MMEC FIRE 32 FIRE SPRINKLER FIRE U L N/_LL, Applicant ID No: 100039-032 Service Center No:1 Expires: 2016-03-31 SEP 2 2 2015 L"- _:•'00,00_-_. 0000 .- CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: MIAMI LAKES, FL Alarm Service Company: (100039-032) Service Center: (100039-032) CHI ALARMS INC. CHI ALARMS INC. 14070 NW 82ND AVE 14070 NW 82ND AVE MIAMI LAKES FL 33016-1547 MIAMI LAKES FL 33016-1547 The Alarm Service Company is Listed in the following Certificate Service Categories: File-Vol No. CCN Listing Category S24065-1 UUFX [Signal and Fire Alarm Equipment and Services] (Protective Signaling Services)Central Station 0000.. 0000.. 0000.... 0000 0000 0000.. 0000.... 0000.... 0000.... 0000.. 0000 0000.. . .0 00000 0000.... 0000 00 0000.00 0 0000 0000 0 00 000 00.0 0000.... . . . 0 0000.. 0000.... .00 . 00. .. . 0 00 . 00 . 0 000 0 0 0 0000 ***THIS CERTIFICATE EXPIRES ON 2016-03-31*** "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" 007553 Local Business Tax Receipt Miami— Dade County,n tYr tate of FloridaF1ori d -THIS IS NOTA BILL - 00 NOT PAY 3999365 ��LBT �/ �+ BUSINESS NAME/LOCATION RECEIPT NO. EXPIRES CHI ALARMS INC RENEWAL SEPTEMBER 30, 2015 14070 NW 82 AVE 4173795 Must be displayed at place of business MIAMI LAKES FL 33016. Pursuant to County Code Chapter SA-Am 9&10 OWNER SEC.TYPE OF BUSINESS CHI ALARMS INC 196 SPEC ELECTRICAL CONTRACTOR PAYMENT RECEIVED EF0000876 BY TAX COLLECTOR Worker(s) 2 $45.00 07/18/2014 •• ECHECK-14-140144 ••• This local Business Tax Receipt only confirms payment of the Local Business Tax. The Receipt is not a license, ...••. '.; permit,or a certification of the holder's qualificatioas,to do business. Holder most comply with any govermnentai • or nongovernmental regulatory laws and requirements which apply to the business. •••••• The RECEIPT NO.above must be displayed on all commercial vehicles-Miami-Dade Code Sec 8a-Z76. •""• ;'. For more information,visit wwwmiamidade,gIlyttexcollector •••••• •• RICK SCOTT,GOVERNOR KEN LAWSON,SECRETARY- STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECTRICAL CONTRACTORS LICENSING BOARD EF0000876 The ALARM SYSTEM CONTRACTOR 1 Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 0 CHI, RENE CHI ALARMS, INC. 14070 NW 82ND AVE MIAMI LAKES FL'33b16 ISSUED: 05/13/2014 DISPLAY AS REQUIRED BY LAW SEVS I!T405130001Z1 ;••••; • so 0 • • • • • •••••• 00 0 -T- (For (For the protection of our professional license holders,this license contains hidden security features to prevent counterfeiting. Unauthorized reproduction is strictly prohibited.and will be prosecuted to the fullest extent of the law) The Department of Business and Professional Regulation(DBPR),issues licenses for many licensed businesses and practitioners in the State of Florida. DBPR is changing the way you interact with state government. Many of DBPR's services are available online at www.MyFloridaLicense.com. We encourage you to utilize these services to make address changes,licensing changes or to renew your license. Name changes require legal documentation verifying the name change,which must be mailed to the DBPR. An original,a certified copy or a duplicate copy of an original or certified copy of a document that shows the legal name change will be accepted,unless the DBPR has a question about the authenticity of the document. If applicable,the DBPR will send a renewal notice to your last known address or email address of record. If you have not received your renewal notice,please call our Customer Contact Center at 850.487.1395 or online at www.MyFloridaLicense.com/contactus. Please refer to your profession's governing statutes and Administrative codes for further information regarding renewals. These may be accessed from our website. ...... .... . AC#, ; 4 i 9.7.4 6 ...... .... ...... ..... . .. ...... ...... .. . .. .. ...... . . . . CHI ALARMS, INC. Serving South Florida for Over 20 Years. UL Listed Installer of Fire Alarm systems S24065. Notifier-Nesco/Fire-Lite Authorized 14070 NW 82nd Ave. Miami Lakes, FL 33016 Distributor Tel: 305-827-2856 Fax: 305-825-2144 State License#EF0000876 Email: ibaezpardo@chialarms.com Prepared by: Isaac Baez Pardo NOTIFIERm Proposal by Honeywell Date: 8/27/2015 Attn: Yosef Shapiro Job name: Browne Hall Job address: 11300 NE 2nd Avenue, Miami Shores, FL 33161-6695 Tel/ Fax: Email: Project: Qty Description 1 Signed and sealed shop drawings. 1 Processing of fire alarm permit. 1 Electrical fire and fire alarm inspection only. 1 Labor to install, program and certify. Excluded: Permit fees. Thank you for your business otal $2500.00 1. Price cover only the material listed above.Any additional equipment shall be paid for by the Customer. 2. Sales are subject to CHT ALARMS,INC.standard credit terms and conditions. 3. Payments:50%deposit,25%at rough electrical inspection,15%at fire final inspection and balance at final electrical. 4. All payments are due upon receipt of invoice.On balance more than 30 days old,it is agreed that a Finance Charge of 1.5%per month will be made.Should the service of an attorney be required to enforce any part of a credit agreement,or for the collection of a delinquent account,it is agreed that the Debtor will pay all costs of collection including attorney fees. 5. Equipment to become property of the Customer upon payment of Selling Price indicated above in full. 6. Customer to provide dedicated 110-volt line and 2 telephone lines to the FACP. 7. The above price is valid for 120 days from date of quotation. 8. All alarm equipment is warranty for one full year. 9. Local authorities may require additional devices. 10. Customer to supply building floor plans. 11. In no event shall Chi Alarms,Inc.be liable for any special,incidental,indirect,speculative,remote,consequential,punitive or exemplary damages,whether arising out of or as a result of breach of contract,warranty,tort(including negligence)arising from,relating to,or connected with the services,equipment,materials,or any goods provided hereunder. 12. Notwithstanding anything to the wntrary herein,if a portion of the services involves the installation and/or maintenance of system associated with security and/or detection of and/or reduction of disk of loss associated with fire,Chi Alarms,Inc.total liability arising out of or as a result of its'performance under this agreement shall not exceed the amount of this agreement. 13. Third Party Indemnification.When Customer has persons,or the property of otters on the premises,or the system extends to protect property or others,Customer agrees to and shall indemnify,defend and hold harmless Chi Alarms, Inc.its employees and agents for and against all claims brought by parties other than the parties to this agreement.This provision shall apply to all claims regardless of rouse,including Chi Alarms,Inc.performance or failure to perform and inducting defects in products,design,installation,maintenance,operation or non-operation of the System,whether based upon negligence,active or passive,warranty,or strict or product liability on the part of Chi Alarms, Inc.its employees or agents,but this provision shall not apply to claims for loss or damages solely and directly caused by an employee of Chi Alarms,Inc.while on Customers premises. 14. Painting,patching and trenching if required not included. 15. Customer agrees to pay for any expenses incurred by Chi Alarms,Inc.due to interruptions in the installation and work schedule of the fire alarm system proposed due to customers inability to providCa"slto the project location and installation area as per approved plans and design.Expenses include but are not limited to expired permits,failure to attend scheduled appointments,non-payment according to schedule of p4ments and9ailure or refusal to authorize a change order and payment for additional work required by the authority having jurisdiction(AHJ).If additional work is required by AHJ and customer refuses to thori�,g SL h work within"4P Chi Alarms,Itjc�r�"s• the right to proceed with the work as required by AHJ to complete the installation and close the permit.If this should occur customer acknowledges that Chi Alarms,Inc.roil I��9g�Ily erpktith to su yme�x(,as outlined in the proposed change order.Customer understand that Chi Alarms,Inc.may place a hold on any existing open permit related to the work described above due to the customer in iility to provide acce�tao�e e7rti�installation area 99• required. 18. Sales tax not included. •••••• •••• •••••• • 17. Permit fee not included. •••••• • • • ;Osseo •••• • •• ••••• Customer acceptance •••••• •• • ••••• In accepting this proposal the Customer agrees to the terms and conditions contained herein.It is understood that they shall pretttail Over any vari4ion ipi,?rms and:••••• conditions on any purchase order or other document that the Customer may issue. • • • • •see••. Purchaser Signature Date Bill to address Print name Title City State Zip Telephone no. 1411111, Secutron", CONVENTIONAL FIRE ALARM CONTROL UNITS MEN MR-2300 SERIES Features Fire Alarm Control Units Listed to UL 864,9th edition- Available in six and twelve zone models • Available in LED and LCD Display configurations • LCD Display versions are equipped with a 2 line by 20 character back-lit LCD display and numerical keypad • Integrated UDACT/Digital Communicator on select models • Front panel and PC programmable • LED Display versions are front panel(using CFG-300 configuration tool)and PC programmable • Remote upload/download capabilities • Base panel is equipped with Class `B" (Style "B") initiating circuits which may be configured as Class "A"(Style°D")using a Class"A"converter module • Initiating circuits may be configured as Alarm,Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble- Description Only Secutron's MR-2300 Series fire alarm control panels Base panel is equipped with Class 'B" (Style "Y") consist of six and twelve zone models which are indicating circuits which may be configured as Class equipped with a two line by 20 character back-lit "A"(Style`Z')using a Class"A"signal converter module LCD display, numerical keypad and an integrated Audible signals may be configured for Steady, UDACT/Digital Communicator. The MR-2300 family Temporal Code,California Code and March Time also includes a twelve zone model that is equipped Indicating Circuits may be configured as Silenceable with an LED display and an integrated UDACT/Digital or Non-Silenceable for both signals and strobes Communicator. In addition the MR-2300 Series family Built-in sync protocols for the following strobe includes remote LCD annunciators, LED annunciators manufacturers: Mircom, Amseco, System Sensor, and remote smart relay modules. Gentex, Faraday and Wheelock • Relay contacts for Common Alarm,Auxiliary/Alarm The MR-2300 Series panels are ideal for both new and (Disconnectable), Common Supervisory and . . 0000 .00000 retrofit applications. Designed for small to medium Common Trouble commercial, institutional and industrial occupancies, Configurable Signal Silence•�nhibit,:Awfo Gignal•••��• these panels are powerful enough to meet today's Silence and One-Man AaTk test installation demands. The MR-2300 Series panels are Subsequent Alarm, Supg0Yisory, §nd•lrouble;••••: configurable by the keypad for onsite programming or operation • 0000 . .. 0000. by a PC for both onsite and remote programming. Easy RS-485 Interface for Rerr}pjP."PAnnVpiatgrs,LCD.•;••• to install and simple to operate and configure,the MR- Annunciators and Remo"SUArt Rel*IClpdeles ...... 2300 Series panels enable the installer to configure the Two event history logs :el�irised of a 200 event system to meet their specific requirements. alarm log for alarm related events and a 200 event•••••• I general log for all other tem. 0000.0 • The MR-2300 Series panels are equipped with a 5 Amp 5 Amp Power Supply •• • :0: •••• power supply, 4-wire resettable smoke power supply Optional modules for additional internall"ayCircuits (300mA max.)and an RS-485 interface for remote LCD and City Tie/Polarity Reversal annunciators, LED annunciators and Remote Smart Optional trim rings for semi-flush mounting Relay modules. All MR-2300 Series panels come complete with a red ' door, black enclosure, durable CAT-30 lock and keyOSA MEA and space to mount up to 12 AH batteries. Optional L approved trim rings are available for semi-flush mounting. 56619 56619 7165-1656:129 352-03-E (LED Models) 7165-1656:131 Issue 4 SECUTRON Page 1 of 6 Canada 25 Interchange Way,Vaughan(Toronto),Ontario L4K 5W3 Telephone:(905)695-3545 Fax:(905)660-4113• Web Page:www.secutron.com U.S.A. 4575 Witmer Industrial Estates,Niagara Falls,NY 14305 Telephone:(888)695-3545 Fax:(888)660-4113• E-mail:mail@secutron.com Catalog Number 1019 • Not to be used for installation purposes. Features Initiating Circuits Indicating Circuits The MR-2300 Series panels are equipped with Class The MR-2300 Series panels are equipped with "B" (Style"B") initiating circuits. The initiating circuits equipped with Class"B"(Style"B") indicating circuits. may be configured as Class "A" (Style "D") using an The indicating circuits may be configured as Class"A" MR-2300-A Class"A"converter adder module. (Style "Z") using an MR-2300-NC4 or MR-2300-NC2 Class"A" signal converter adder module.The audible Each Initiating circuit may be configured for one of the signals may be configured for Steady,Temporal Code, following modes of operation: California Code and March Time. • Alarm (Without smoke detector verification) Each of the indicating circuits may be configured for Verified Alarm (With smoke detector one of the following modes of operation: verification) • Waterflow Alarm (Water flow sensors) Silenceable Signal • Sprinkler Alarm (Sprinkler flow sensors) ' Non-Silenceable Signal Latching Supervisory • Silenceable Strobe Non-Latching Supervisory • Non-Sileneceable Strobe • Monitor(non-latching input used mainly for correlating to a relay circuit) The MR-2300 has built-in sync protocols for the • Trouble-Only(for monitoring a trouble condition following strobe manufacturers; Secutron, Amseco, from an external device) System Sensor, Gentex, Faraday and Wheelock. 13 Series Protocol UDACT/Digital Communicator The MR-2300 Series panels have the i3 Series protocol The MR-2300 Series panels are equipped with a fully built-in. The panels support the two-wire i3 Series integrated UDACT/Digital Communicator which allows smoke detectors (2W-B/2WT-B). These i3 series for the reporting of events to a monitoring facility. The detectors communicate with the MR-2300 to provide UDACT/Digital Communicator can be configured for the following status information: single or dual line operation and uses the Security Industry Association (SIA) and Ademco Contact ID Open circuit trouble protocols. The UDACT/Digital Communicator is This trouble indicates that loop is broken. configured via the main display and keypad on the main panel. Comrawaication trouble ...... Thislwx"e indicates that there is a fault in the line or In addition to its reporting functions, the integrated •:•••• the with it a lis Iloo s sy•t.. panel cannot communicate UDACT/Digital Communicator can be used to connect to the MR-2300 panel from remote computers for • ••••••• uploading and downloading of configuration data. It • Dirtyde;ief 000000 also allows for the viewing of the event history logs. ••••• This trouble indica%rthat one or more device on the The MR-2300 series panels have two event history ••••• i3 zope ip*grty. ::-:-- logs comprised of a 200 event alarm log for alarm •••••• •' " '• related events and a 200 event general log for all •• Out of Sensitivity:': other events. •""• This.t"4 indicates that one or more device on the i3 zone is But of caositivity range and cannot detect The integrated UDACT/Digital Communicator can be an aINH condition. •• configured for either DACT or UDACT operation. In • •0 DACT mode the Digital Communicator reports common Freeze trouble alarm,trouble and supervisory information. In UDACT This trouble indicates that a device on the i3 zone has mode the Digital Communicator reports point specific detected a freeze condition, e.g. the temperature is information. below 41 OF/5°C (available only on model 2WT-B). The built-in protocol removes the need for the 2W-MOD Maintenance Module. Page 2 of 6 SECUTRON Issue 4 Catalog Number 1019 Not to be used for installation purposes. MR-2300 Series LCD Version Models MR-2306-DDR Six Zone LCD Display Fire Alarm Control MR-2312-DDR Twelve Zone LCD Display Fire Alarm Control Panel Panel with UDACT/Digital Communicator The MR-2306-DDR is equipped with six Class "B" (Style "B") The MR-2312-DDR is equipped with twelve Class"B"(Style"B") initiating circuits and two Class"B"(Style"Y")indicating circuits initiating circuits and four Class"B"(Style"Y")indicating circuits rated @ 1.7 Amps maximum.(Total of 5 Amps) The MR-2306- @ 1.7 Amps maximum.(Total of 5 Amps). Two MR-2300-A Six DDR is equipped with a built-in UDACT/Digital Communicator. Initiating Circuit Class AConverter Module may be used for Class One MR-2300-ASix Initiating Circuit Class"A"Converter Modules "A"(Style"D")wiring of the initiating circuits.One MR-2300-NC4 may be used for Class "A" (Style "D") wiring of the initiating Four Indicating Circuit Class"A"Converter Module may be used circuits. One MR-2300-NC2 Two Indicating Circuit Class "A" for Class "A" (Style 7') wiring of the Indicating circuits. The Converter Module may be used for Class"A"(Style"Z')wiring MR-2312-DDR has a built-in UDACT/Digital Communicator and of the indicating circuits. The cabinet will support up to 12 AH the cabinet will support up to 12 AH batteries. The panel can batteries.The panels can be semi-flush mounted with the optional be semi-flush mounted with the optional MR-2312-FT trim ring. MR-2300TRB trim ring. Note:Not ULC listed. Note:Not ULC listed. Dimensions Dimensions MR-2306-DDR: 20"H x 14.5"W x 4.5"D MR-2312-DDR: 26"H x 14.5"W x 4.5"D MR-2306-FT: 22.5"H x 17"W MR-2312-FT: 28.5"H x 17"W R-2300 Series LED Version Models MR-2312-LDR Twelve Zone LED Display Fire Alar Control Panel with UDACT/Digital Communicator 0000 The MR-2312-LDR is equipped with twelve Class� B'4Style "B").+•++. initiating circuits and four Class"A':(STyle"Y")indicating circuits ,• rated @ 1.7 Amps maximum.(ToWlOf5pps)T'v9:4FJ2300-A....;. Six Initiating Circuit Class"A"ConjWAUpdules may 4e used for. • Class"A"(Style"D")wiring ofthe init4ogg circuits.ppe 14R-2300-:••••; NC4 Four Indicating Circuit Clas!f&90verter rrodg%may bei.... used for Class"A"(Style"Z")wiring of the indicating circuits. The • + MR-2312-LDR is configurable bythekeaped(usirFtke 6FG-300 : Configuration Tool)for onsite pro��99rmming or by a PUfor both* :• onsite and remote programming.TihM312-LDR has a built-in •• UDACT/Digital Communicator and the calbinet W:1"plkirt up to••"'• 12 AH batteries.The panel can tt-sep$,llush maunted with the;,...; optional MR-2312-FT trim ring. •• • .. :0: • • Dimensions • MR-2312-LDR: 26"H x 14.5"W x 4.5"D MR-2312-FT 28.5"H x 17'1N Issue 4 SECUTRON Page 3 of 6 Catalog Number 1019 Not to be used for installation purposes. Remote nnunciator MR-2306-ATR/MR-2312-ATR Remote LED Annunciators The MR-2306-ATR and MR-2312-ATR provide 8 or 16 points respectively of LED annunciation. Both models MR-2300-LCDR Remote LCD Annunciator feature bi-coloured LEDs which are auto-configurable The MR-2300-LCDR provides LCD remote annunciation for either Alarm (red) or Supervisory(amber). The LED through a 2 line by 20 character LCD display. The MR- annunciators have indicators for A.C. On, Common 2300-LCDR provides control switches for System Reset, Trouble and Signal Silence and control switches for Signal Silence, Fire Drill and Acknowledge as well as System Reset, Signal Silence, Lamp Test and Buzzer a numeric keypad to access the menu functions. The Silence. The MR-2306-ATR and MR-2312-ATR are common control functions can be disabled on a per equipped with a keyswitch which allows for enabling function basis. The MR-2300-LCDR has LED indicators and disabling of the Common Control functions. Both for A.C. On, Alarm, Supervisory, Trouble and CPU models are available in a red finish and mount in a 4-gang Fail. The MR-2300-LCDR comes complete with a red electrical box. Note: ULC Listed as an Ancillary Device. enclosure and a CAT-30 Lock and key. Note:ULC Listed CID Vi as an Ancillary Device. RAM-1016TZDS Remote LED Annunciator The RAM-1016TZDS Remote LEDAnnunciator provides 16 points of LED annunciation. The RAM-1016TZDS comes standard with bi-coloured LEDs which are automatically configured for either Alarm (Red) or Supervisory(Amber) • and individual trouble LEDs. The RAM-1016TZDS has • •••• MR-28�T�•9R12 9martftelay Module indicators forA.C.On,Common Trouble and Signal Silence • The MR�P612-SRitpre�ides twelve configurable relay and controls for System Reset,Lamp Test,Fire Drill,Buzzer •• Silence and Signal Silence. In addition it allows for the control • •; circuitsorated @ 281PDC'1 amp(resistive). Each circuit switches to be disabled on a per function basis.The RAM- can 4ecgr?fJ]ured a5&"gmally Open(N.O.)or Normally 1016TZDS mounts in a MMX-BB-1001 R enclosure. 00;00 Closetl'(N.C.)contcWt*r=ach relay is equipped with an ••"• LED.thatnit wh&Wrelay is energized. The relays can bg configured 99 re1Ay per zone(1 to 1), Common "� m .... _ on Alarin, Common on.Supervisory or programmable "'• for aA(bs ;)r adjacent zone configuration. An adjacent :....: zone confiratioroUl turn on an adjacent zone when • • the oonliqured zone is active. A chaining configuration CFG-300 Configuration Tool allows for multiple relays to turn on. The MR-2312-SR12 The CFG-300 Configuration Tool is rewired for onsite front is DIP switch configurable and connects to the RS-485 panel programming of the MR-2312-LDR panel.The CFG- bus. The MR-2312-SR12 comes complete with a red 300 plugs into the MR-2312-LDR main board to provide a two enclosure and a CAT-30 lock and key line by 20 character LCD display. The MR-2312-LDR panel is configured using the CFG-300 and push buttons on the main board. In configuration mode,the initiating and indicating circuit disconnect buttons act as function keys. Removing the zone labels reveals the programming function buttons. The CFG-300 tool is used for configuration purposes only and not for normal operation. Page 4 of 6 SECUTRON Issue 4 Catalog Number 1019 Not to be used for installation purposes. Adder Module I, I MR-2300-A Six Initiating Circuit Class"A"Converter MR-2306-R6/MR-2312-R12 Relay Circuit Adder Module Modules The MR-2300-A converts six Class`B"(Style"B"initiating The MR-2306-R6 provides six configurable relay circuits, circuits on the MR-2300 main board to Class"A"(Style"D") rated @ 28 VDC, 1 amp (resistive). The MR-2312-R12 circuits. The MR-2300-A is equipped with wire leads to provides twelve Form C configurable relay circuits,rated @ connect to the MR-2300 main board. It mounts to the right 28 VDC,1 amp(resistive). On both models each circuit can of the main board Class"B"(Style`B") initiating circuits. be conf igured as a Normally Open(N.O.)or Normally Closed Two MR-2300-A modules are required to convert all twelve (N.C.)contact. Each relay is equipped with an LED that is lit initiating circuits on an MR-2312 series panel. when the relay is energized. The relays can be configured as relay per zone(1 to 1),Common on Alarm,Common on I I Supervisory or programmable for logical or adjacent zone configuration. An adjacent zone configuration will turn on _0000 adjacent zone when configured zone is active. A chaining configuration allows for multiple relays to turn on. � srssr sr.'. MR-2300-NC4 Four Indicating Circuit Class "A" Converter Module The MR-2300-NC4 converts four Class"B"(Style"Y") indicating circuits on the MR-2300 main board to Class MR-2300-PR Polarity Reversal/City Tie Module "A"(Style"Z")circuits. The MR-2300-NC4 is equipped The MR-2300-PR provides outputs for city box and polarity with wire leads to connect to the MR-2300 main board. reversal applications.As a city tie module the MR-2300-PR It mounts to the right of the main board Class"B"(Style provides an interface between the control pane�iritlicating "Y") indicating circuits and is used with the MR-2312 circuits and a master box. It provide soff-prerrrrees signal•••• • series panels. transmission for systems thatsmust•comply Vitlt NFPA •• requirements forAuxiliaryProtediel Systems.066 clarity.... •• reversal module the M R-2300-PR pfovides an Interface; ; between the control panel ancL316ftse polafl1r fteivec' • It provides off-premises signal Mahtmissiorf for'Systems* ....,,.1,....., hull_ :00 that must comply with NFPA ruMVftents. .. .. . *0 00000 0000.. 00000 6 0 0000.. 0.00.0 . ... 0000.. MR-2300-NC2 Two Indicating Circuit Class "A" Converter Module The MR-2300-NC2 converts two Class"B"(Style"Y") MR-2300-X Active End-of-Line Resistors indicating circuits on the MR-2300 main board to Class The MR-2300-X are power saving End-of-Line resistors "A"(Style"Z")circuits. The MR-2300-NC2 is equipped which eliminates the need for an additional battery cabinet with wire leads to connect to the MR-2300 main board. or larger batteries in order to meet the 60 hour standby It mounts to the right of the main board Class"B"(Style requirement. (Please refer to Battery Calculation Chart in "Y") indicating circuits and is used with the MR-2306 manual formore details.)The MR-2300-X can also be used series panels. when larger batteries than can fit in the cabinet are required. Issue 4 SECUTRON Page 5 of 6 Catalog Number 1019 Not to be used for installation purposes. Specifications AC Input Unfiltered supply(full wave rectlfi )' 120VAC @ 60Hz Power limited/24VDC unfiltered/1.7A max at 49°C Standby Power Auxiliary Relays(Common alarmJs /trbJand auxiliary 24VDC standby batteries second alarm) Charging Capability FormC/28VDC/1 A max 4 to 12 AH Current Consumption Indicating Circuits Model Standby Alarm Power limited/24VDC unfiltered/1.7A @ 49*C per MR-2306-DDR 142 mA(112 mA*) 312 mA(282 mA*) circuit. Maximum 5 Amps. MR-2312-DDR 174mA(104 mA*) 444mA(394 mA*) Aux supply{non resetabie} MR-2312-LDR 11 64m(104 mA*) 424mA(364 mA*) Power limited/22.3VDC regulated/500mA max 4-wire smoke supply{resetabie} Power limited/22.3VDC regulated/300mA max Ordering information Moftl Description Control Units MR-2306-DDR* Six Zone LCD Display Fire Alarm Control Unit with built-in UDACT/Digital Communicator MR-2312-DDR* Twelve Zone LCD Display Fire Alarm Control Unit with built-in UDACT/Digital Communicator MR-2312-LDR Twelve Zone LED Display Fire Alarm Control Unit with built-in UDACT/Digital Communicator Remote Annunciators and modules MR-2300-LCDR Remote LCD Annunciator(Red enclosure)(Note: ULC Listed as an Ancillary Device.) MR-2300-LCDW Remote LCD Annunciator(White enclosure)(Note: ULC Listed as an Ancillary Device.) MR-2306-ATR Eight zone Remote LED Annunciator(Note: ULC Listed as an Ancillary Device.) MR-2312-ATR Sixteen zone Remote LED Annunciator(Note: ULC Listed as an Ancillary Device.) RAM-1016TZDS Sixteen zone Remote LED Annunciator with individual Trouble LEDs MR-2312-SR12 Remote Relay Module with red enclosure MMX-BB-1001R Red enclosure for RAM-1016TZDS i Adder Modules *:*sea• MR--=jR • $ix Initiating Circuit Class"A"Converter Module MR-1W04MC4 • %ePour Indicating Circuit Class"A"Converter Module • •••• MR-2300•NC2 •••• Two Indicating Circuit Class"A"Converter Module •...; MR-2$b6-R6 ••'• six Relay Circuit Adder Module ••••• MR•231Q-412 • Vwelve Relay Circuit Adder Module •••;•• MR-?x300;;R •••, I;olarity Reversal/City Tie Module .....• MR•"U-Ai ••• active End-of-Line Resistor • • • Accestsories •....• •••••• MRS ;li ' Black Semi-Flush Trim Ring for MR-2306 enclosures :...•: MR-2312- *me glack Universal Semi-Flush Trim Ring for MR-2312 enclosures • • CF(:-30p, Configuration Tool for MR-2312-LCDR UIMA Universal Programming Tool Note:Not ULC Listed Page 6 of 6 SECUTRON Issue 4 Catalog Number 1019 • Not to be used for installation purposes. Secutron reserves the right to make changes at any time without notice in prices,colors,materials,components,equipment,specifications and models and also to discontinue models. I!V)luf! :':i:)i5 '-b, � � r dY ® i r L i +IM �a. Features That Make a Difference: • Uses HSPA(3G)network for high-speed, reliable and low- cost communications to an IP receiver • Automatically switches to 2G (EDGE/GPRS) if 3G service is 3G technologyfrom DSC! not available • Compatible with control panels The 3G3070CF connects the alarm path shall be annunciated at the that communicate using the control panel to the HSPA network supervising station and at the Contact ID format and reports alarm signals directly to a protected premises within not more • Full event reporting monitoring station receiver(Sur-Gard than 24 hours of the failure. System I/II/III/IV).The 3G3070CF uses • 4 on-board'inputs the HSPA network to ensure low- How it Works • 4 on-board outputs(open cost, high-speed and reliable alarm The 3G3070CF can be used as collector) communications and is compatible either a Sole Communicator or as a SIM card(included) with control panels that communicate Backup Communicao.*Vftn being • Activation and initialization via using the Contact ID format. used at a W(i CommtWttor the.... • automated telephone activation The 3G3070CF is compliant 3G3070t�A replace the phone •. ...... .... ...... system (VRU), web-user or with the latest requirements for line co 1*6 0.0�on the pad el and • Communications Methods as as soon a�jt detects.tDat in alarm:•••• mobile interface provided by per UL864 and NFPA72 2010 needs c 1 sen C24 Communications ��e�nsmi� �� d";". Edition. It can be used in Fire the alar"ociiipss the"SPA netwo4.�.. • PTM (Panel Transmission Monitoring applications as a single immediatel)iAhen btin'g.us'ed as a..... Monitor)switches from PSTN communications technology, backul3p#*> ornmunicator assesses • to cellular on unsuccessful in which case any failure of the the cormectiom to tha PSTN phone••• • communication attempts communications path shall be line,anV orgy O the event of a phole, • • ® annunciated at the supervising station line failurt'Will Tt sendo V�traffic System I/II/III/IV monitoring • Compatible with SunGardtoring within 5 minutes of the failure,or it across the HSPA netwbfk 0 the station receivers can be used as part of a multiple monitoring station. communications technologies(for In instances where the control panel • Includes UL listed power example in conjunction with a DACT). does not support Contact ID,the supply,transformer and 7 Ah When used as a back-up provision 3G3070CF has inputs pre-set to rechargeable battery shall be made to monitor the integrity transmit fire alarm,fire supervisory or • UL 864 listed of each communication path and system trouble. CSFM listed failure of any communications • C; _..... .. Alarm signals are transmitted directly without the need of Specifications a clearinghouse to the IP linecard of the monitoring station receiver(Sur-Gard®System I/II/III/IVj. Dimensions................................................11-1/2"x 10"x 3" (29.2 cm x 25.4 cm x 7.62 cm) Activating & initializing the unit Input Voltage.............................................................120 VAC Activating and initializing the 3G3070 can be done using Current Draw..............................................................300 mA the automated telephone activation system(VRU), mobile Operating Environment ................0°to 48°C(32°to 120°F) interface or web-user interface provided by CONNECT 24. Weight...........................................................12.8 lbs(5.8 kg) No special tools are required. UL Listing The 3G3070CF is UL listed under File S4019, Listing guide UOXX,as a sole or backup communicator for Commercial Fire monitoring installations.When used as a sole communicator the 3G3070CF will send its heartbeat once every 97 seconds ensuring that three heartbeats will be received at the supervising station within the 300 second window.When used as a backup communicator the 3G3070CF will monitor the other communication method (DACT)and send a daily test transmission to the supervising station. CSFM Listing The 3G3070CF has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code. Rate Plan .... ...0a6t-effec%v .ra?e plan have been negotiated and are •o available thrtougjauthonzeclrnaster resellers.Contact your • •"mitoring",Itbn or viE01% .connect24.com to find a "43ter reselibr. 6 6.9 0• •• 0rde0hg*0nforMW6n: ... .. .. . .. .. 3G3070CF.USA.....Uoiiaeo9ek Wireless Commercial Fire Alarm •:• •• • • Communicator(U.S. Model/SIM Card • • • IWedi • i • 0 N V 8 0 m a •OnrnUni ations SG=32/42SK Series PUSH Die-Cast MetalPUL PULL IPStationsManua till Single Action Dual Action Descdpticrt The SG-32SK and SG-42SK Series are single contact,key-reset,manual -,.'t s pull stations designed to meet the requirements for many applications. They are constructed from a rugged,but lightweight,die-cast metal alloy • Single or Dual Action for increased performance and longevity. This series of stations is available in single action(PULL lever)or dual action(PUSH bar and PULL lever) models. • Screw Terminal Connections The series of stations represented on this data sheet (SG-32SK or SG- . DC and AC Voltage Contact Ratings 42SK) are provided with one normally open contact connected to a terminal strip that can accommodate wiring from#22 to#12 AWG. (See Spectrum data sheet for additional contacts). Contacts are gold plated • Gold Plated Alarm Contacts to minimize risk of corrosion. All models have been tested by UL and found in compliance with the pull force requirements of the Americans • Surface or Weatherproof Back-box with Disabilities Act(ADA). p • Deeper Back-boxes available to Coiwcdion provide more space for wire and/or The stations are operated by pulling the handle marked"PULL"on the •addrevable moduli;:':• front of the unit as far down as it will go. At that point,the handle will •• ...... lock in place and is easily visible from up to 50 feet. The activation •• • : •*00 •0 handle is reset by opening the station with the key,placing the"PULL" • OptiontMI ton ColOf oLabels T'••0 handle to its normal upright position (resetting the toggle switch when *00*** ••••• •• applicable)and relocking the station. On the dual action,the"PUSH"or ContaCtt..�$ee $p9C�ulll data SO@ . optional"EMERGENCY"bar moves inward allowing the"PULL"handle to be operated by a single hand. - moi:. '. 00000 MourN Confrgc�cs •••• Semi-Flush--All models mount on a standard single-gang back-box. Pt111. •••: Surface Mount Interior--Use SigCom SGB-32S or the deeper metal back-box(SGB-32SD). Surface Mount Exterior--Use Si Com SGB-32C SG-WP or the g ( ) deeper die-cast, weatherproof back-box (SGB-32CD) STl1. c L usQ= FM MEA •,• � R vt NYC Approved Signal Communications Corporation LISTED APPROVED SGO53008 „ �Cr�Ct7f(t7�7S . Listings: UL,ULc,FM,CSFM,MEA Temperature: -40°to 150°17,90%relative humidity @ 100017 Switch Rating: SG-32-Micro switch 1 Amp @ 30 VDC,1 Amp @ 125 VAC SG-42-Toggle switch 2Amps @ 125 VDC,2Amps @ 240 VAC Pull Station Weight: 1.2 lbs Pull Station Dimensions: 4 3/4"h x 3 1/4"w x 1.1"d Surface-Mount Backbox Dimensions: 4 3/4"h x 3 1/4"w x 2 1/4"d(outside);2 1/8"d(inside)cast and sheet metal Deep Surface-Mount Backbox Dimensions: 4 3/4"h x 3 1/4"w x 2 3/4"d(outside);2 5/8"d(inside)cast and sheet metal Color. Red with raised white letters,white"PULL"bar and white"PUSH"bar(Dual Action)with raised red letters Cnh>rm 3-Micro switch SG- -- SK-- - -- - . 4-Toggle switch Blank-Standard lock("B"key) 2-Standard pull station 6-"EMERGENCY"push bar in place of"PUSH"bar A-Cat 15 lock assembly D-Cat 60 lock assembly B-Cat 30 lock assembly E-SC 10 lock assembly C-Cat 45 lock assembly F-PK525 lock assembly 00 -No logo SC-SigCom logo I-Dual action 2-Single action Example: SG-32SK2-SC=Micro switch,standard,single action,SigCom logo with standard`B"key lock Note: All stations are supplied with one break-rod,one key and installation instructions Accessories SGB-32S ••••0 Interior,red,surface mount,sheet metal backbox with 3/4"knockouts %13-32SDDeep-etegQ;!red,surface mount,sheet metal backbox with 3/4"knockouts •e•CCaWP 0#410 WeatheP48("red,surface mount,die-cast metal backbox with one tapped hole for 3/4"NIPT fitting(same as SGB-32C) • • 0000••rp :00_1+32CD 6 ,Deep Wee j*UO* red,surface mount,die-cast metal backbox with one tapped hole for 3/4"NPT fitting :_-;MR0I *660 612 packbfSeored,plastic(acrylic)break-rods for spares or replacement 0000• • 06 •09.09 ••0906 •• • •• •• :0609.e Speehx:aeries'data s9eet 0000•• • • • , • • • �', t.)ll For New York City MEA listed stations, see NYC Stations data sheet Signal Communications Corporation P.O.Box 2588 Woburn,MA 01888 Tel.:781 933 0998 Fax.:781 933 5019 SGO53008 COOPER Notification 00 Weatherproof Appliances - Series AH Audibles,AS Audible Strobes, MT Multitone Strobes, RSS Strobes and ET70 Speaker Strobes and Weatherproof Mounting Accessories l Description: Designed for life safety, performance and reliability, Cooper All models may be synchronized using the Wheelock DSM Sync Notification's Wheelock cost effective weatherpoof notification Modules, Wheelock Power Supplies or other manufacturers appliances include: panels incorporating the Wheelock Patented Sync Protocol. The Weatherproof Appliances Series horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP Strobes RSSWP horn strobe models are 4-wire appliances; the strobes can be Horn Strobes ASWP synchronized while the audible can be connected to a coded fire Horns AH-24WP,AH-12WP alarm system or can be set to produce any of eight selectable Multitone Horn Strobes MTWP tones. Multitone Horns MT Speaker Strobes ET70WP Speakers ET-1010 Features: All strobe models are UL dual listed meeting both UL1638 Approvals include: UL Standards 1971, 1638,464 and 1480 and UL1971 requirements. As dual listed appliances, these California State Fire Marshal(CSFM), New York City weatherproof strobes, horn strobes and speaker strobes are listed (MEA), Factory Mutual(FM), Chicago(BFP)and ULC. See for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. agency approvals by model number on page two of this With an extended temperature range of—31°F to 150°F (-35°C document to 66°C), Wheelock weatherproof appliances meet or exceed UL 0 Compliance with the following requireWm". NFPA, UFC, outdoor test requirements for rain,humidity and corrosion resistance ANSI 117.1, OSHA Part 29, 1910.165 ADA• •••••• while providing multiple strobe intensity options, including the • • highest strobe ratings available for area coverage per NFPA 72 Weatherproof with exten88d terrlperatra Fite of-40°F'to strobe spacing tables(up to 185 candela forwall mounting and 177 150°F(-40°C to 66°C)*"';'• "'• ""'• candela for ceiling mounting). • Dual Listed strobe models(rUL 1638 a . 00 0 • • • To enable weatherproof mounting, Cooper Notification provides 0 Industry's highest strobe gppdLla optianS..' .�... the industry's widest choice of mounting options for surface or 0 Synchronize using the VW�=eic�k SyntNodules or p>s�els• • unique semi-flush installation. Models are available for surface � • mounting to Wheelock weatherproof backboxes on walls or ceilings. with built-in Wheelock Patented SynA-rotocol ...... The optional WP-KIT allows the weatherproof backboxes (106, 0 Models with field sele4bnfte,dBA and candela settiAQs WPBB or WPSBB) to be mounted to a recessed electrical box Wall or ceiling mountin•options :•••:• 000000 for concealed conduit installation. For semi-flush installation, the g ,� p . . WPA'and WFPA"kits allow a customer to mount the weatherproof Surface of semi-flush r1'Iptyitinj . ... ;••••; appliances to a recessed electrical box without the need for an IN/OUT wiring termination accepting;";l 118 AWG wires external weatherproof backbox. See the Backboxes, Plates and Gaskets Table on page three of this document for a summarization at each terminal of these mounting options and the required accessories. The series RSSWP,ASWP,AH-24WP,MTWP-2475W,and MT-12/24 have UL/ ULC approval down to-40°F. The ET-1010 and ET70WP have UL approval down to-40°F. The AH-12WP has UL approval down to-31°F. uL Ew. U: FM ® MEA APPROVED E5946 151-92-E 7125-0785:131(ASWP) S5391 7125-0785:146(ET70WP) S2652 7125-0785:156(MTWP) 7300-0785:154(RSSWP) NOTE:All CAUTIONS and WARNINGS are identified by the symbol B.All warnings are printed in bold capital letters. ,A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.000PERNOTIFICATION.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INS IALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. Wall Mount Ceiling Mount Wall or Ceiling Mount �r RSSWP MTWP RSSWP MTWP on MT AH ASWP ET70WP ASWP ET70WP ET-1010 # Strobe Order Code Strobe Order Code RSSWP-2475W-FR Red 9013 RSSWP-2475C-FR Red 4338 Audible Order Code RSSWP-2475W-FW White 3034 RSSWP-2475C-FW White 4446 AH-24WP-R Red 7416 RSSWP-24MCWH-FR Red 5161 RSSWP-24MCCH-FR Red 5167 AH-12WP-R Red 7415 RSSWP-24MCWH-FW White 5165 RSSWP-24MCCH-FWWhite 5187 Horn Audible Strobe Audible Strobe MT-1 2/24-R Red 5023 ASWP-2475W-FR Red 9012 ASWP-2475C-FR Red 4251 ASWP-24MCWH-FR Red 5137 ASWP-2475C-FW White 4502 Speaker ASWP-24MCWH-FW White 5140 ASWP-24MCCH-FR Red 5149 ET-1010-R Red 3135 Multi-tone Strobe ASWP-24MCCH-FW White 5157 ET-1010-W White 3137 MTWP-2475W-FR Red 8420 Multi-tone Strobe UL Max.Current AH MTWP-2475W-FW White 3112 MTWP-2475C-FR Red 4457 MTWP-24MCWH-FR Red 5132 MTWP-2475C-FW White 4478 t24VDC 12 VDC MTWP-24MCWH-FW White 5134 MTWP-24MCCH-FR Red 5102 High(99)dBA 0.192 Speaker Strobe MTWP-24MCCH-FW White 5122 Med(95)dBA 0.108 ET70WP-2475W-FR Red 9077 Speaker Strobe Low(90)dBA 0.058 ET70WP-2475W-FW White 3179 ET70WP-2475C-FR Red 4452 ET70WP-24185W-FR Red 4885 ET70WP-2475C-FW White 4454 UL Reverberant dBA @ 10 Feet ET70WP-24185W-FW White 4891 ET70WP-24177C-FR Red 4845 alts 1/8 1/4 1/21 2 4 8 W ET70P-24135W-FR Red 4872 ET70WP-24177C-FW White 4859 ET70WP-24135W-FW White 4875 ET70WP-24115C-FR Red 4550 ET-1010 77 80 83 86 87 92 94 ET70WP-24115C-FW White 4732 ET70WP 78 81 84 87 90 93 95 Candela Ratings • RSS,ET70WP and f638 UL 638 ASWP i6iiixiosp UL 1971+ 1 MTWP UL Max Current Model Number Agency Approvals • 77°F @e-49�: • Strobe Only) High Med Low ZJVY• 30*0• :00 g0 115. e 0.138 0.168 0.155 0.150 Strobe UL MEA CSFM FM BFP RSSWP-2475 X X X X - 475C• 15 180 0.138 0.168 0.155 0.150 RSSWP-24MCWH X X - - • 135 • 4:5 •96'• 0.300 0.355 0.340 0.335 RSSWP-24MCCH X X MC60" 185 ' 185 f/� 0.420 0.480 0.465 0.460 Audible Strobe •• 115• •11P5 •47 • 0.300 0.355 0.340 0.335 ASWP-2475 X X X X X • ASWP-MCWH X - X - - • 177 177 97*10• 0.420 0.480 0.465 0.460 ASWP-MCCH X - X - - 1,�5� 185 . 1&5 V7• ; 0.420 **Wall mount rating only Multitone Strobe X24177 • 177 'r'1 7 78 • 0.420 MTWP-2475 X X X X MTWP-MCWH X X UL Max.Curren K0T /MT MT MTWP-MCCH X X - Audible) 'La VDC 12 VDC Homs/Audibles BA HI STD HI STD AH-24WP X X X X X Horn 0.108 0.044 0.177 0.034 AH-12WP X X X X X Bell 0.053 0.024 0.095 0.020 MT-12/24 X X X X X March Time 0.104 0.038 0.142 0.034 Speaker Strobe Code 3 Horn 0.091 0.035 0.142 0.034 ET70WP-2475 X - X X - Code 3 Tone 0.075 0.035 0.105 0.021 ET70WP-185 X - X X - Slow Whoop 0.098 0.037 10.142 0.035 ET70WP-177 X - X X - Siren 0.104 0.036 0.152 0.030 ET70WP-115 X - X X - Hi/Lo 0.057 0.025 0.114 0.026 ET70WP-135 X - X X - Mounting Accessories 3 WFP WFPA 10B WPSBB WPBB WBB Gasket Kit Order Code WP-KIT 4486 Mounting Options: Backboxes,Plates,Gasket Kits Flush Plates WFPA-R Red 4698 Surface Mount Flush WFPA-W White 4701 Exposed Conduit Concealed Conduit Mount WFP-R Red 4696 WFP-W White 4697 RSSWP Strobes WPSBB WPSBB+WP-KIT WFP Backboxes ET70WP Speaker Strobes 10B 106+WP-KIT WFP 10B-R* Red 5046 ASWP Horn Strobes WPBB WPBB+WP-KIT WFPA IOB-W* White 5047 WPSBB-R* Red 9751 AHWP Homs WBB WFP WPSBB-W* White 3033 ET-1010 Speakers WBB - WFP WPBB-R* Red 9014 WPBB-W* White 4692 MTWP Multitone Horn Strobes 10B 1013+WP-KIT WFP WBB-R Red 2959 Multitone Horn 106 106+WP-KIT WFP WBB-W White 2960 *106,WPSBB and WPBB models include weep holes and plug in the event that moisture may have entered the appliance SERIES MTWP APPLIANCES SYNCHRONIZED STROBE Wiring Diagrams OPERATION WITH CODED FACP MTWP m 0 o/ StrStrbe out be SERIES MTWP AUDIBLE APPLIANCE AND STROBE OPERATE Syne IN UNISON.RED AND BLACK SHUNT-WIRES ARE SUPPLIED. NAC., Module or PS Audible FROM TO NEXT pre' � Circuit PRECEDING + + APPLIANCE FACP Supply APPLIANCE RED - BLACK - OR EOLR OR FACP NAC#2 •••• Note: Strpbe ci cuit regGijq%gdhstant W911W, SERIES RSSWP/ASWP APPLIANCES SYNCHRONIZED /• STROBE AUDIBLE DSM MODULE SINGLE CLA•SsVA"NAC blAdUIT """ ...... SERIES RSSWP,ASWP,AHWP,MTWP AND MT-12/24 STROBE � • :�• �• • • NAC SYNC • • •• ••••• APPLIANCES CIRCUIT •• • •• . • ••• FROM TO NEXT OUT +our1 PRECEDING + ± APPLIANCE 0+IN16• • ST ' ';' • APPLIANCE OR OR EOLR MINU♦1 • WP "5• • 000 FACP FACP + UDIBLE •••••• 9 • • . 04 ••• MINUS 2r.• • * *00 •0 / • + — +IN 2 RSS ••"swT ST STROBE NAC +Quiz CIRCUIT RETURN Note: Models are available in Red or White. Contact Customer Service for Order Code and Delivery. #Refer to Data Sheet S7000 for Mounting Options NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.dba Cooper Notification standard terms and conditions. ARCHITECTS AND ENGINEERS SPECIFICATIONS General Weatherproof notification appliances shall be UL listed for outdoor use.Weatherproof Strobe appliances shall be I�isted under UL Standard 1638(Standard for Visual Signaling Appliances)for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired).The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit or concealed conduit, or semi-flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes Weatherproof Strobe appliances shall produce a minimum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available.The strobes shall operate over an extended temperature range of—40°F to 150°F (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP). Weatherproof Audibles and Audible/Strobe Combinations Weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464.The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/Strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings.Multitone Audible/Strobe combinations shall have independent inputs for the audible and strobe.The strobes shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers and speaker/strobes shall be listed for Indoor/Outdoor use under UL Standard 1480.All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construction for extra protection and improved audibility. Speakers without strobes shall be Wheelock Series ET-1010.They shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker with strobes shall be Wheelock Series ET70WP.They shall be available for surface or semi-flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Synchronization Modules When synchronization of strobes or temporal code-3 audibles is required,the appliances shall be compatible with the Wheelock Series DSM Sync Modules, Wheelock Power Supplies or other manufacturers panels with built-in Wheelock Patented Sync Protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Series ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on Series MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi-flush mounting to walls or ceilings.Surface mounted appliances shall mount to Wheelock 106, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box.Semi-flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. ...... .... e . e e e e ee ee e e e e ee..ee eeee .ee.ee e e e e ee..e. ..eeee e ee eee. e e e e .eeee ee . eeee e e .eeee a ee ..eeee e e e e 0000 ee . e. e. e e e e...ee . e e e e e ee.e e e IVE ENLOURMI AND SU41011Is NICET CERTIFICATION 3 YEAR WARf2AN-" S9004 WP 11/12 NJ Location 273 Branchport Ave. Long Branch, NJ 07740 800-631-2148 Cooper Notification is Wheelock*® SAFEPATH' WAV rc� COOPER Notification SYS TEM �45 SEJ V.SOR'q , Photoelectric ' Smoke Detectors System Sensor i3-series smoke detectors represent f,s significant advancement in conventional detection. The i3 family is founded on three principles:installation TM ease,intelligence,and instant inspection. Features Installation ease.The i3 line redefines installation ease with its Plug-in detector line,mounting base included plug-in design.This allows an installer to pre-wire bases(included with heads).The large wire entry port and in-line terminals provide Large wire entry port ample room for neatly routing the wiring inside the base.The base In-line terminals with SEMS screws accommodates a variety of back box mounting methods as well as Mounts to octagonal and single-gang back boxes,4-square back direct mounting with drywall anchors.To complete the installation,i3 boxes,or direct to ceiling heads plug into the base with a simple Stop-Drop'N Lock"action. Stop-Drop'N Lock attachment to base Intelligence.i3 detectors offer a number of intelligent features Removable detector cover and chamber to simplify testing and maintenance.Drift compensation and Built-in remote maintenance signaling smoothing algorithms are standard with the i3 line to minimize nuisance alarms.2-wire i3 detectors can generate a rernvtc•KD- indicated maintenance and smoothing algorithms indicated maintenance signal when cbnn�%d to the#10/0OD2 •••••• Simplified sensitivity measurement loop test/maintenance module or a p^N equipped:its tl,i3 • Wide-angle,dual-color LED indication protocol.The SENS-RDR,a wireless dcg","?plays theSi!rtsftivityof i3****•• detectors in terms of percent-per-fool IM lation. • • ••.•.. •Loop testing via EZ Walk feature ••.. .. . • • � Built-in test switch Instant inspection.The i3 series provides wide-angle reM Ind ••;••. green LED indicators for instant inspection Nthe deVt&r's. 00000••0• condition:normal standby,out-of-sensitivity,alarm,or freeze trouble.•••0;0 When connected to the 2W-MOD2 loop Ost7maintenance module •• • 0 •. 000000 ora panel with the i3 protocol,the EZ Walk loop test 1'eetsl"*s available on 2-wire i3 detectors.This;atuvcrifies the initiating loop••0•: � wiring by providing LED status indication at each detuceto p• • • Agency Listings F M MEA MSFM �(ET� LISTED APPP ED approved approved \,��us 5911 3011446 7272-1653.152 290-01-E 2093 3180932 Ci)3 Smoke Detector Specifications Smoke detector shall be a System Sensor i'Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type(Model 2W-B,4W-B)or a combination photoelectric/thermal(Model 2WT-B,4WT-B)with thermal sensor rated at 135°F (57.2'C).The detector shall include a mounting base for mounting to 3'/2-inch and 4-inch octagonal,single-gang,and 4-inch square back boxes with a plaster ring,or direct mount to the ceiling using drywall anchors.Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up,normal standby,out of sensitivity,alarm,and freeze trouble(Model 2WT-B,4WT-B)conditions.When used in conjunction with the 2W-MOD2 module,2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum:35V Maximum Ripple Voltage 30%peak to peak of applied voltage Standby Current 2-wire:50 NA maximum average;4-wire:50 NA maximum average Maximum Alarm Current 2-wire:130 mA limited by control panel;4-wire:20 mA @12 V,23 mA @ 24 V Peak Standby Current 2-wire:100 NA;4-wire:n/a Alarm Contact Ratings 2-wire:n/a;4-wire:0.5 A @ 30 V AC/DC Physical Specifications Dimensions(including base) 5.3 inches(127 mm)diameter;2.0 inches(51 mm)height Weight 6.3 oz(178 g) Operating Temperature Range 2W-B and 4W-B:32°F to 120°F(0°C to 49°C);2WT-B and 4WT-B:32°F to 100'1`(0°C to 37.8°C) Operating Humidity Range 0 to 95%RH non-condensing Thermal Sensor 135°F(57.2°C)fixed Freeze Trouble 2WT-B and 4WT-B only:41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal(standby) Blink every 5 seconds off Out of sgr"i�ty off Blink every 5 seconds •••••• Freezcpti4w,• of f • Blink every 10 seconds •• Alarm •• • pff••. Solid •0000• 0•0 0 0 60.•600 0•••:OrderingInformation .000 hermal Wiring Alarm Curniint • • 2W-B CG•••0 2-wire 130 mA max.limited by control panel 60.60•• . 6060 0:00#0 2WT-B•••• : %0••• 2-wire 130 mA max.limited by control panel • 4W-B • W0•••• 4-wire 20 mA @ 12 V,23 mA @ 24 V • 4WT-B •60••60• 6 • s • 4-wire 20mA@12 V,23mA@24V 6060.• • 60 Accessnroes•••• • • 6060•••• • • 2W-MpDA. • }wii test/maintenance module RT Removal/replacement tool SENS R •• Sensitivity reader A77-AB2 Retrofit adapter bracket,6.6 inch(16.76 cm)diameter STEM 82009 5Yz«m s sa, 3825 Ohio Avenue•St.Charles,IL 60174 r'<nd�a�Pen�e�al�nnz,�nleam�na_9 w,�nrnrtnnnce 2,s,ts,-s«ms.n,n,core n, .SENSOR Phone:800-SENSOR2•Fax:630-377-6495 cerenl pindu«nrori including The latest wisbn of his data heel. .a05-0318-007•:/07--2169 COO RNotification Series MIZ Mini Horn Appliances ii SERIES MIZ Description: Features: Wheelock Series MIZ piezoelectric Mini Horns are compact Approvals include: UL Standard 464, California State Fire electronic alarm appliances that are listed under UL Marshal(CSFM),New York City(MEA),and Factory Mutual Standard 464 for Audible Appliances in Public Mode Fire (FM) Protection Systems. The Series MIZ-24S models provide Field selectable settings for Temporal(Code 3)or Continu a field selectable Continuous or Code 3 horn tone when ous Horn connected directly to a fire alarm control panel. They Synchronized code 3 horn when used with Wheelock Sync can also provide a synchronized code 3 horn tone using Module the Wheelock DSM Sync Modules or Wheelock Power Designed to meet or exceed NFPA/ANSI standards Supplies. The series MIZ appliances are attractive, offer Convenient mounting to any standard single-gang box high sound output along with low current draw and are Beauty plugs to cover mounting screws ideal for alarm signaling in individual rooms, apartments, No additional trimplate required for flush mounting hotels,motels and offices.Color choices of red or off-white will blend with any decor. Fast installation with In/Out screw terminals using#12 to #18 AWG • High sound output with low current draw • Wiring Diagrams (for all models) Available in red or off-white color 4.000 FROM • • 4.4.4.4. 4.4.4.4.•• PRECEDING + + TO NEXT Applications: • • • • APPLIANCE - - APPLIANCE Individual Rooms 00 0 + •00• #• •4.4.4.4.• 0000 000000 OR FACP OR EOLR Apartments 600:00 0 • Hotels •••••• 4.4.4.4. 4.• • • • Motels •����• ; •�4.• ����� + - Offices • • •4..•4.• •4. • ••.4.• .. 4.4. . .. .••... 4..4.4..0 • . . 4. 4. .4..4.4.. Specifications and Ordering Information • • + • • • 4. ••4.4.4.4. Order Mounting Agency Approvals •4. • ; Model Code Description Options ** UL MEA CSFM FM MIZ-24S-R 8485 24 Volt, Red B X X X X **Refer to Data Sheet S7000 MIZ-24S-W 8484 24 Volt, White B X X X X for Mounting Options. General Notes: • Mini Horn models are Listed for indoor use with a temperature range of 32°F to 120°F(0°C to 490 C)and maximum humidity of 93% RH±2%. UffY 'OF FM •Rated Input voltage(eitherfiltered DC or unfiltered full-wave-rectified FWR): MEA APPROVED 16-33 VDC(for 24 VDC MIZ-24S models) S5391 151-92-E 71250785:161 Architects and Engineers Specifications The notification appliance shall be a Wheelock MIZ-24S audible appliance or approved equal. The Notific ion Appliance shall be electronic and shall have field selectable settings for Temporal (Code 3) or continuous horn and support co led systems operation. The anechoic sound pressure measurement on Temporal(Code 3)setting shall be 87 dBA minimum at 24VD 33. The anechoic sound pressure measurement on Continuous Horn setting shall be 87 dBA minimum at 24 VDC. Operating voltages shall be 24 VDC using filtered power or unfiltered power supply(full-wave-rectified). All models shall have provision for standard reverse polarity type supervision and IN/OUT wiring using terminals that accept#12 to#18 AWG wiring. The appliances shall be mounted indoors and mount on standard single-gang electrical backboxes requiring no additional trimplates or adapters. Table 1: UL Listed Models and Ranges ' RMS current ratings are per UL average RMS method. Reverberant dBA Anechoic dBA UL max current rating is the Average Per UL 464 @ 10 ft @ 10 ft maximum RMS current within Regulated RMS Mounting the listed voltage range(16-33v Model to Current' Options for 24v units For strobes the Voltage (AMPS) Continuous Code 3 Continuous Code 3 pons UL max current is usually at the dBA dBA dBA dBA minimum listed voltage(16v for 24v units). For audibles the 24 VDC 0.025 83.2 78.8 87.9 87.9 B max current is usually at the maximum listed voltage (33v MIZ-24S for 24v units). For unfiltered UL max* 0.026 85.8 81.3 90.6 89.7 B FWR ratings, see installation instructions. NOTE: All CAUTIONS and WARNINGS are identified by the symbol. All warnings are printed in bold capital letters. AWARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION,INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. A WARNING:CONTACT WHEELOCK FOR THE CURRENT"INSTALLATION INSTRUCTIONS"(P84408)AND"GENERAL INFORMATION"SHEET(P82380)ON THESE PRODUCTS.THESE DOCUMENTS UNDERGO PERIODIC CHANGES. IT IS IMPORTANT THAT YOU HAVE CURRENT INFORMATION ON THESE PRODUCTS. THESE MATERIALS CONTAIN IMPORTANT INFORMATION THAT SHOULD BE READ PRIOR TO SPECIFYING OR INSTALLING THESE PRODUCTS,INCLUDING: •TOTAL CURRENT REQUIRED BY ALL APPLIANCES CONNECTED TO SYSTEM SECONDARY POWER SOURCES. •FUSE RATINGS ON NOTIFICATION APPLIANCE CIRCUITS TO HANDLE PEAK CURRENTS FROM ALLAPPLIANCES ON THOSE CIRCUITS. •THE VOLTAGE APPLIED TO THESE PRODUCTS MUST BE WITHIN THEIR RATED VOLTAGE RANGE. •FAILURE TO COMPLY WITH THE INSTALLATION INSTRUCTIONS OR GENERAL INFORMATION SHEETS COULD RESULT IN IMPROPER INSTALLATION, APPLICATION, AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. •CONDUCTOR SIZE(AWG),LENGTH AND AMPACITY SHOULD BE TAKEN INTO CONSIDERATION PRIOR TO DESIGN AND INSTALLATION OF THESE PRODUCTS, PARTICULARLY IN RETROFIT INSTALLATIONS. Wheelock products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained ag(ttptrationally tested in accordance with their installation instructions at the time of installation and at least twice a *,�ee*e'more oftenend in acabirdarste with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and tes*ig must be performed by qualified personnel for proper operation in accordance with all of the latest .ULwal Fire Prrifaotion Assoaation(NFPA), Underwriters'Laboratories(UL), National Electrical Code(NEC),Occupational Safety and J-lealth,4dministration(OSH4),Uale state,county,province,district,federal and other applicable building and fire standards,guidelines, 7eg6Ie1ons, laws ar"codes ipglyding, but not limited to, all appendices and amendments and the requirements of the local authority havinV jurisdicltipU JAMJ). •����• NtTR:•Due tgeogthduous 4&48#ment of our products,specifications and offerings are subject to change without notice in et eertiMence wilts WMelock Ifit.Mndard terms and conditions. WE ENCOURA*G**EVD SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY S1700 MIZ 06/11 NJ Location 273 Branchport Ave, Long Branch,NJ 07740 P:800-631 2148 F:732-222-8707 Cooper Notification is Wheelock"® SAFEPATH' wnv COOPER Notification File No:S24065 CCN: UUFX Service Center No: 1 r Expires:05/14/2016 U L Issued:05/15/2015 CENTRAL STATION - FIRE FIRE ALARM SYSTEM CERTIFICATE (NFPA 72) THIS CERTIFIES that the Alarm Service Company is included by UL LLC in its Directory as qualified to use the UL Listing Mark in connection with the certificated Alarm System.This Certificate is the Alarm Service Companys representation that the Alarm System including all connecting wiring and equipment has been installed and will be maintained in compliance with requirements established by UL.This Certificate does not apply in any way to the installation of any additional signaling systems,such as;fire,smoke,waterflow, burglary, holdup, medical emergency, or otherwise,that may be connected to or installed along with the Certificated Alarm System. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. LIMITATION OF LIABILITY: UL LLC makes no representations or warranties,express or implied,that the Alarm System will in all cases prevent any loss by fire,smoke,water damage, burglary, hold-up or otherwise, or that the Alarm System will in all cases provide the protection for which it is installed or intended. By the Alarm Service Company providing this Certificate and the Protected Property acceptance of this Certificate,the Alarm Service Company and the Protected Property acknowledge and agree that UL does not assume or undertake to discharge any liability of the Alarm Service Company or any other party. UL is not an insurer and assumes no liability which may result directly or indirectly from inspection of the equipment,failure of the equipment,failure to conduct inspections, incorrect certification, nonconformity with requirements,failure to discover nonconformity with requirements,cancellation of the Certificate or withdrawal of the Alarm Service Company from inclusion in ULs Directory prior to the expiration date appearing on this Certificate. OPERATIONAL REQUIREMENTS:The Alarm Service Company bears the responsibility for the correctness of the installation; maintenance of the system documentation;periodic system inspection and testing; maintaining and providing any necessary repairs. All operations and maintenance shall be conducted in the manner prescribed by the NFPA standard referenced. All required service is to be provided for in an appropriate contract. System documentation is defined to include any"As Built Drawings";the records of any"Acceptance Testing"; and the records of all periodic system testing and maintenance. SYSTEM DESCRIPTION:This system is installed and operated in accordance with standard NFPA 72,2002 edition. Area Covered:BUILDING Authority Having Jurisdiction:Miami Dade Fire Rescue Department Responding Fire Department:MIAMI DADE FIRE RESCUE SYSTEM DEVIATIONS FROM REFERENCED NFPA STANDARDS NONE Protected Property: Alarm Service Company: BARRY UNIVERSITY BROWNE HALL CHI ALARMS INC. 11300 NE 2 AVE • • 14070 NW 82ND AVE MIAMI SHORES,FL 3316 •• ••: . . . • • • MIAMI LAKES FL 33016-1547 . •. . • • • •.• . . . • • • . .. . • SN: FC5593730 ;• ... . . . ... . . File No: S24065 CCN: UUFX Service Center No: 1 Expires: 05/14/2016 U L Issued:05/15/2015 Entry No:5332607 Version:7 CENTRAL STATION - FIRE FIRE ALARM SYSTEM CERTIFICATE DESCRIPTION FOR Certificate Serial No: FC55937389 Protected Property: Alarm Service Company. BARRY UNIVERSITY BROWNE HALL CHI ALARMS INC. 11300 NE 2 AVE 14070 NW 82ND AVE MIAMI SHORES,FL 33161 MIAMI LAKES FL 33016-1547 Comments and Clarifications: AS REQUIRED BY LOCAL JURISDICTION System Description: Area Covered: BUILDING Authority Having Jurisdiction: Miami Dade Fire Rescue Department Responding Fire Department: MIAMI DADE FIRE RESCUE Testing and Maintenance Contract date: 07/15/2014 SYSTEM DEVIATIONS FROM REFERENCED NFPA STANDARDS NONE Automatic Fire Detection and Alarm Service Coverage is Selected Area 2 -Smoke Detectors : 0-Ionization 2-Photoelectric Manual Fire Alarm and Guard's Tour Supervisory Service 6 -Manual Fire Alarm Boxes Alarm Notification and Annunciation Devices 8-Visual Signals : Type-Strobe 48 - Horns 6-Audible/Visual Signals : Type-Strobe Control and Transmitter Unit MIRCOM SECUTRON 2312, DSC 3G3070,SECUTRON 2312 Remote Monitoring UL Listed Central Station File: S2623, Service Center Number: 0 CENTRALALARM CONTROL INC 13973 SW 140TH ST MIAMI FL 33186-552p•• ••; ••. ; Alarm Retransmission tFie� artmorrt•• Public Telephone Netwbrk antPPublic•fetel one Network Alarm Transmission Method: Cellular Digital Alarm Communicator *00 000 see .. . . . . . . . . . So: .. see 000 fit . ... . . . . . . . . . . . . .. .. . . . .. .. ... 0 0 0 ... . . Miami-Dade Fire Rescue Fire Alarm Pre-Submittal Checklist MIAMI.[aADE Based On NFPA 72 2007'Ed.&NFPA 1 and 1012009'Ed. e Building Dept.Pro ess Number is(Begins with C gr M): Date: 1 Project Name: / is provided in title block of plans. YES NO N/A 2 Address in title block shal!,,ilihatch address in"Buif ng Dept.Computer System"and attached permit application.If address contains a specific building,floor,4bite,or unit number or letter,it shall be provided in title block,to match BuildingDept.Computer System. 3 The total cost of the installation to the customer is$ 15ya 6-P and a copy of the contract or a notarized affidavit from the owner showing this amount is attached. 4 Fire Alarm Systems costing more than$5,000 are sealed or stamped by a Florida Registered Professional Engineer. 5 The total number of DEVICES and COMPONENTS being installed is 6 The alarm qualifiers state license number is EC EH EY # and a copy is attached to plans. 7 Complete,current manufacturer's Specification and Installation sheets are attached for all control units,components,devices, modules and relays listed on Legend. 8 Is this permit application for fire alarm work a result of a Notice Of Violation(NOV)issued by Miami-Dade Fire Rescue?If yes,a copy of the Notice of Vi lation is attached. 9 This fire alarm: is required under (fill in the Occupancy Chapter&Section from NFPA 101 OR,U is a life safety equivalency OR,U is a non-required system or component. This is an"EXISTING(Local)Fire Alarm System"and is stated as such on the plans.AHJ will require documentation of prior 10 approval of system as a(Local)Fire Alarm System in the form of the original Fire Dept.approved job copy set of fire alarm plans or certified microfilm copy of same. 11 This is a"NEW Local Fire Alarm System"and is stated as such on plans. This is an"EXISTING Central Station Service Fire Alarm System"and is stated as such on the Plans.A copy of the existing 12 BUILDING UL or ETL certificate,or FM Placard,specifically identifying this protected premise by address,and uniquely identifying 61-1 this building's fire alarms stem,is attached. If the company that issued the existing certificate or placard for this building's fire alarm system is different than the company 13 applying for this permit;is the required Affidavit to Work on another Company's Certificated or Placarded Fire Alarm System Provided? 14 This is a NEW Certificated of Placarded "Central Station Service Fire Alarm System"and stated as such on the plans. 15 If this is a NEW"Central Station Service Fire Alarm System,"a copy of the UL or ETL certificate of FM placard from the contractor, or from the Central Station Service Company,issuing the building certificate/placard,is attached. This is an"EXISTING Remote Supervising Station Fire Alarm System"and is stated as such on the plans.AHJ will require 16 documentation of prior approval of system as a Remote Supervising Station Fire Alarm System in the form of the original Fire Dept. approved job copy set of fire alarm plans or certified microfilm copy of same. 17 This is an"EXISTING"Sprinkler Waterflow and Supervisory System"only and is stated as such on plans. This is a NEW"Sprinkler Waterflow and Supervisory System"only and is stated as such on plans.The system is monitored off-site 18 and provides emergency forces notification through a Certificated(_)or Placarded(_)"Central Station Service Fire Alarm"and is stated as such on the plans. A complete detailed statement of the"SCOPE OF WORK"is stated on the plan.Please note that the complete tenant space,in its 19' entirety,will be inspected for compliance with NFPA 72(2007)and NFPA 101 (2009),or prior editions of these codes if applicable. Also outline scope of work with bolded dashed lines floor Ian and riser for existingsystems. 20 The buildingis"New" or"Existing" and is indicated as such on the plans. 21 A description of the building is provided,including fire sprinkler systems,fire suppression systems,number of stories,square footage per floor,and elevation of the last occupied floor if over 5 stories. 22 A location Key is provided showing the area of proposed work within the building.Also provided is a site key for projects with multiple buildings showing locations of all buildings with addresses 23 All interconnected Fire Alarm Control Panels are arranged to function as a single sstem and monitored for integrity er NFPA 72. 24 The class/style is shown for all Initiating Device Circuits(IDC),Signal Line Circuits SLC and Notification Appliance Circuits(NAC). 25 The maximum number of each device type is provided for each IDC based on device load or each SLC,based on class and style, per NFPA 72 and the manufacturer's specifications. 26 A specific"Sequence of Operation"including all alarm,supervisory,trouble and control functions such as fire sprinkler,door release,smoke control,elevator recall,suppression systems,and transmission of signals offsite,etc.arespecified on the Ian. 27 The type of monitoring station,(Listed Central Station,Remote Supervising Station,Listed Proprietary Supervising Station),where alarm,trouble,and supervisory signals are transmitted to,is clearly and concisely stated in the"Sequence of Operations" 28 The method of communication to the monitoring station is included on the riser. 29 If this building contains elevators that are not capable of recall,it shall be stated as such on plans and written documentation on 0. elevator contractor's letterhead statin that"Elevators are not capable of providing recall function",is provid2d, 30 If this building does not contairld firgdVrr9 slisteni,and the fire alarm panel is used exclusively for elevator recall;plans shall clearly designated panel as"Irlevator Recall o ro a iso Panel" 31 Manufacturer,model number cvd unique ayinboWomeaelt�odel number is provided for each device,module,relay,component, ower supply and fire alarm o Rol el% e(lf od i thQ s bol legend. 32 Each device,module,appliance and component is identified with its own unique number and indicated on the floor plans and riser. 33 Floor plans are drawn to 1/8"scale or,if using another scale,all device coverage is diagrammed on the floor plan and all room dimensions are included. • ••• ••• ••• •• ••• Designed by: ••• • • • • • Phone#: Signature: Created by: MDFR 08/2012 ••T4HIS IS A REQUf l2U,5O§UMEPT ON ALL FIRE ALARM PLAN SUBMITTALS • • • • • • 10F2 . .. .. . . . .. .. ... . . . ... . . Miami-Dade Fire Rescue Fire Alarm Pre-Submittal Checklist MIAMI.D�ADE Based On NFPA 72 2007'Ed.&NFPA 1 and 101 2009'Ed. r 34 All rooms&spaces are labeled indicating their use,and the occupant load has been provided for all assembly use rooms with an occupant load of 50 or greater. 35 All new,existing,replaced or relocated devices are indicated on the floor plans and a complete riser diagram showing all new and existing devices of the entire fire alarms stem is provided. 36 Ceiling type and height is provided for all ceiling mounted devices. 37 All devices and components located in areas in which the voltage,temperature,and humidity variations exceed those conditions stated in NFPA 72,are listed for conditions and all such areas are identified. 38 A note is provided on the plans stating"Room containing FACP,Booster Power Supply,Voice Evacuation and Amplifier panel(s), Dialer,or Radio is mechanical) ventilated",as applicable. 39 The FACP or Remote Annunciator and as applicable EVAC panel or Remote Microphone is located at the main entrance/lobby in single tenant buildings,or in a common area main entrance/lobby of a multi-tenant building. 40 The FACP,Communicators,Amplifiers,NAC Panels and all sub-panels are protected with a smoke detector. 41 If a complete automatically activated system,not less than one manual fire alarm pull box shall be provided to initiate system.The pull box shall be located where AHJ specifies. 42 If a manually activated system,the travel distance to reach a pull station is less than 200'feet and within 5'feet of all required floor and/or building exits. 43 All automatic initiating devices are shown and are located in accordance with NFPA 72,the manufacturer's specifications,and accepted engine rinractices. 44 Area smoke detectors,if used,shall provide coverage throughout the entire smoke compartment. 45 All visual notification appliances are placed per tables in NFPA 72 and each strobe has its candela rating on the floor plan and riser. 46 All corridor spaced strobes are placed a maximum of 100'feet apart and within 15'feet from the ends of the corridor. 47 All spaces throughout the entire building shall meet the audible characteristics of NFPA 72 and NFPA 101. 48 Bell used for water flow annunciation is shown on floor plan,riser and legend.Bell shall be located so as to be visible and heard from roadway or parking area within close proximity to Fire Dept.Connection(FDC). Flow Bell sequence of operations shall state as follows: 49 A)Flow bell shall activate upon water flow only. U-1 oll B)Flow bell shall continue to sound as long as water is flowing. C FACP shall not be capable of silencing Flow Bell. 50 The location of Backflow Preventer(BFP),Post Indicating Valve(PIV)and Fire Dept.Connection(FDC)are indicated on the floor tans,riser and legend forsprinkled buildings. 51 Walls,partitions,racks,shelves and equipment that do not extend to ceiling,are shown with their heights indicated on floor plan. Duct detectors or relays for duct detectors are shown on the floor plan and riser for all systems greater than 2000 CFM supply or 52 greater than 15,000 CFM return.Duct detectors shall derive their 24 volt do power source from the Fire Alarm System to satisfy the monitoring for integrity requirements of NFPA 72.4.4.7,for devices and conductors.Please show compliance on riser. 53 A complete system riser diagram is provided showing each floor of the building with all zones and circuits labeled. 54 The conductor size,type,and quantity are provided for each circuit on riser. The fire pump is monitored for:A)Pump or Motor Running,B)Loss of phase,C)Phase reversal,and,if applicable,D)Controller 55 connected to an alternate source;and are indicated at U a continuously manned location,or U the supervised fire alarm (� system. 56 Show all relays on floor plan and clarify function on riser.(Sprinkler,Wet Chem.,Dry Chem.,Clean Agent,Foam,Elevator Shunt- Trip,Music Shut-Down,Door Release and other building control functions. 57 The AMPACITY of each Power Supply and Notification Appliance Circuit is specified for each FACP&Power Supply Panel on tans.In addition,the individual device current is specified on riser for each notification appliance Homs/Speakers/Strobes). 58 The total"ACTUAL"footage to the last device along with voltage drop calculations are provided on plans for each NAC for each ower supply. 59 The wattage tap is indicated for all speakers. 60 The wattage capacity and load is provided for each amplifier. All load values for"STANDBY"&"ALARM"used in calculations are high-lighted on the manufacturer's specification or installation 61 sheets.Also,AMPACITY of equipment/components and circuits are high-lighted on manufacturer's sheets. 62 This system includes Emergency Voice Evacuation and is provided with 15 minutes of secondary alarm power.Required in all high rises and assembly occupancies with an occupant load greater than 300. 63 This system is being provided back up power by an emergency generator and will provide 4 hours of standby power plus the appropriate seconds alarm power. 64 Battery calculations,detailed in chart form,showing all information required per NFPA 72.4.4.1.5.3.1 are provided on plans for each back-up ower supply. The replacement of the Fire A W Control Panel with anythineNher than the exact same make and model number panel;or the 65 addition of a Fire Alarm Cont�I Panel f hi%jill arojtid�or replace any of the functions of the existing FACP,shall require the fire alarm system to I up-grade o curro mt codeestlndprdl,•or cft of Miami-Dade County,Part III,Chapter 14,Article III,Section 14-66 9 & 10 • •• • • • •• 66 If the scope of work includes greater than one-half of the entire fire alarm system's devices,then the entire fire alarm system shall be up-graded to current code standards,per code of Miami-Dade County,Part III,Chapter 14,Article lll,Section 14-66(9). • ••• ••• ••• •• • • • • • •• • • •• • • • • • • • • • Designed b ••: :• ••• ••• ••• ••• 9 Y� Phone#: Signature: Created by: MDFR 08/2012 ••ABIs IS A RE40UORE ROJUMEIT ON ALL FIRE ALARM PLAN SUBMITTALS • • • • • •