RC-13-1361 (2) � Y Rodriguez Ravelo Architects Inc. 901 S. Federal Highway Suite 200 Fort Lauderdale,Florida 33316 Telephone 954-764-0907 Telefax 954-764-0940 October 30, 2013 Miami Shores Building Department Comments 10050 NE 2nd Avenue Miami Shores, FL Re: Process No. RC13-1361 Project Address: 1175 NE 101 St. Miami Shores, FL Building Department Response: SEE DELTA 2 CLOUDED RESPONSES ON PLANS. Structural 7 . 1 . THIS IS A LEV EL. -3 ALTERATION, THE RECONSTRUCTION AND MODIFICATIONS OF THE HOUSE SHOOLD CONIF'1,Y v MITI-I THE REQUIREMENTS OF F.S.C. 2010, RESIDENTIAL CODE. THE CC` MMZfNTS PROVIDED ARE CREATED TO ASSIST .I"HE DESIGNPROFESSIONAL iN PROVING THE REQUIRED INFORMATION TO COMPLY WITH THE RE0UIREME-:NTS C)F THE CODE ,AND ORDINANCES AND SHOULD OfN",.%` BE USE AS A GUIDELINE, THE DESIGNED PROFESSIONAL 15 RESPOND; BLE TO ENSURE COMPLIANCE WITH ALL REQUIREMENTS,ENTS, SCHEDULE A MEETING WITH THE DESIGN PROFESSIONALS AND THE REVIEVtifER, Response: Only the existing flat roof portion of the existing residence is being replaced by a new pitched roof. The altered existing flat roof area, including the garage and shed representsapprorx 5`0%oo of the existing total interior house floor area. The existing sloped roof portion of the residence is staying completely intact. We are not removing any of the structural members in the sloped roof area. In addition, the new pitched roof area will piggy back over less than 10% of the existing pitched roof. We are also adding approximately 90 s.f. to the rear of the house and a covered roof patio area in the courtyard. a?. 2. THE VALUE DEPICTED ON THE PERMIT APPLICATION IS NOT INDICATIVE OF THE SCOPE OF WORK TO BE PERFORMED AT THIS PROPERTY, PROVIDED A DETAIL BREAK DOO/N ESTIMATE OF THE PROJECT COSTINCLUDING LABOR AND AAA"I"'ERIAL; .. Response: See revised quote 3. 3, 00 NOT DELEGATE INVESTIGATION TO THE CONTRACTOR. I Response: There are existing conditions that must be verified by the contractor. Any discrepancies or concerns found during construction must be reported to the Architect. 4, 4_ SITE PLAN, SHEET A-1 1,0- SHO" u' THE LOCATION OF THE WATER SERVICE TO THE PROPERTY Response: See sheet A-1.1.0 delta 2. . 5. SHEET A-2,1 .0- ROOF DEMOLITION HAS A NOTE SHOWING THE EXISTING PITCHED ROOF TO REMAIN. BASE ON THE LEVEL OF ALTERATION THE ENTIRE ROOF SYSTEM SHOULD BE REPLACE. Response: The existing Pitched roof will not be altered. Only 5% of the area adjacent to the renovated portion will be affected by overframing. Therefore, no replacement of the existing elements is required per the code criteria of Level 3. 6. 6, SHEET A-4.1 .0 PROVIDE DETAIL AND SPECIFICATION FOR THE NCV)/ ROOF SYSTEM. SOFFIT AND FASCIA SHOULD COMPLY WITH THE REQUIREMENTS OF THE CODE. Response: See sheet A-6.1.0 delta 2 for fascia and soffit details. 7. 7 PROVIDE DETAIL AND SPECIFICATIONS FOR ALL WALL TYPES, INCLUDING BATHROOMS AND WALLS SUPPORTING CA13INETS AN[) PLUMBING FIXTURES, Response: See sheet A-6.1.0 delta 2 for details and referenced on sheet A3.1.0. B. 8. SHEET S-2, ROOF FRAMING PLAN- SHOW 'THE LOCATION OF THE L-1 BEAM, . 9. DETAIL 3/S3- PROVIDE DETAIL OF THE SILL PLATE AND THE DOUBLE TOR PLATE FOR THE KNEE WALL. 10, 10. SHEET S-2., TRUSS ANCHOR CONNECTOR SCHEDULE. PROVIDE THE Response: See structural plans. 1 . 11 . PROVIDE SHOP DRAWINGS AND ENGINEERING OF THE SHORING. QVgT;=M Tn RIF LISF DURING THE DEMOLITION, Response: Shoring shall not be required for this scope of work. 12- 12. PROVIDE SPECIFICATIONS FOR THE EXISTING FOUNDATION 714Ar WILL SUPPORT THE NEW C-1 COLUMN AND PROVIDE A DETAIL FOUNDATION TO TRUSSES SHOWING ALL COLUMN CONNECTIONS. 13. 13. PROVIDE HORIZONTAL REINFORCEMENT ON THE NEW CBS WALL$. 14. 14. PLEASE CHECK PLANS FOR COMPLIANCE WITH CODE REQUIREMENTS, DO NOT REMOVE VOIDED SHEETS, CLOUD IN ALL REVISIONS AND OR CORRECTIONS, AN[) PROVIDE A NARRATIVE tNr)!r.ATlQN THE LQCATIwDN OF THE CORRECTIONS. Response: See structural plans and structural response sheet. Plumbing -4- 'S T I Jl, ` F 5 C Itj 11"S t"s k 5, t'j -N"tk a� k'n"t'3 11111"1110cp Response: Approved Sheet is provided. Electrical Add smoke / carbon monoxide detectors to existing area. -1 A jL- Response: See sheet E1.1.0 Delta 1 previously addressed and Delta 2. 2. Show all devices in the area to be renovaTea wuri uruuit jsum vvila rAI -V orODer sjDacincl. Fixed glass is well space, Response: See sheet E1.1.0 Delta 1 previously addressed and Delta 2. 3. All �ecep'tacles in the garage to be G. F. I. protected. Response: See sheet E1.1.0 Delta 1 previously addressed and Delta 2. 4. Add 120 volt T'P/Wp GF1 receptacle Response: See sheet E1.1.0 Delta 1 previously addressed. 6. Hi hats to be I. Q. rate a. z Response: See sheet E1.1.0 Delta 2.