Loading...
ELC-15-1422 Miami Shores Village Building Department 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 _ Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 kb BUILDING Master Permit No. ELUS" 1Y22 PERMIT APPLICATION Sub Permit No. [—]BUILDING xx ELECTRIC ❑ ROOFING M REVISION M EXTENSION MRENEWAL []PLUMBING ❑ MECHANICAL ]PUBLIC WORKS ❑ CHANGE OF []CANCELLATION M SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 11300 NE 2nd Avenue-Andreas Bldg.#16 City: Miami Shores County: Miami Dade Zip: 33161 Folio/Parcel#: 11 21.36 000 0050 is the Building Historically Designated Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE FFE: OWNER:Name(Fee Simple Titleholder):Barry University Phone#: Address:11300 NE 2nd Avenue City: Miami Shores State: FL Zip: 33161 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Coleman, James R./Thermal Concepts, Inc. Phone#: 954 472-4465 Address: 2201 College Avenue City: Davie State: FL Zip: 33317 Qualifier Name: James R. Coleman Phone#: 954 472-4465 State Certification or Registration#i EC13002675 Certificate of Competency#: DESIGNER:Architect/Engineer: N/A Phone#: Address: City: State: Zip: Value of Work for this Permit:$ 1 1 5. 9 q Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Q Repair/Replace ❑ Demolition Description of Work: 'Controls, low voltage Specify color of color thru tile: Submittal Fee$ 50 �_Permit Fee$ 4/80.-Oce CCF$ CO/Cc$ Scanning Fee$ Radon Fee$ DBPR$ Notary$_ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$' ?r, TOTAL FEE NOW DUE'$ / L L (Rev1sed02/24/2014) 77777777 ones „ Miami Shores Village PBm?�t Type.Eletri� oBFcia! 10050 N.E.2nd Avenue NE r... ... Watic Cta&5lffOO low 1 Wage Miami Shores,FL 33138-0000 u z 401 P@lTlIIC,a�tfGS:APPRO�IrI :',.” LiL6,=='moo` Phone: (305)795-2204 ,. \ �.hTES H �ORt1)p'. IFssr�tail1�'� Expiration: 12/12/201 Project Address Parcel Number Applicant 11300 NE 2 Avenue Number: Andreas Buildil 1121360010160-21 BARRY UNIVERSITY INC Miami Shores, FL 33138-0000 Block: Lot: Owner Information Address Phone Cell BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractor(s) Phone Cell Phone __......_• _.._•.�.__._._.._...._.____..__. Valuation: $ 15,990.00 THERMAL CONCEPTS INC (954)472-4465 _. . Total Sq Feet: 0 Type of Work:CONTROLS, LOW VOLTAGE Available Inspections: Additional Info: Inspection Type: Classification:Commercial Review Electrical Scanning:3 Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $9.60 DBPR Fee Invoice# ELC-6-15-55927 $7.20 06/15/2015 Credit Card $472.70 $50.00 DCA Fee $7.20 Education Surcharge $3.20 06/10/2015 Credit Card $50.00 $0.00 Permit Fee $479.70 Scanning Fee $3.00 Technology Fee $12"80 Total: $522.70 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above-paTed contractor to do the work stated. Qffl June 15, 2015 Authorized Signature:Owner / Applicant / Contractor / Agent 5ate Building Department Copy June 15,2015 1 Bonding Company's Name(if applicable) N/A Bonding Company's Address _ City State Zip _ Mortgage Lender's Name(if applicable) NSA Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the Job site for the first inspection which occurs seven 17j days after the building permit is issued. in the absence of such posted notice, the inspection will not be approved and a reinspection fel will be charged. Signature_ ,jSignature 16A, �- OWNER or AGENT IV CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this q l / day of -20 ��.by �_day of J s u 11 20 �� .by �tJ�A� �Q�Awho ersonally known o James R. Coleman who is personally known to me or who has produced as me or who has produced himself as identification and who did take an oath. identification and who did take an oath. t�11111111111/// NOTARYPUBLIC: \,N�����P�gTAgpyF�i�, NOTARY PUBLIC: • G� 28,? Flo••. 1 Sig � •� ��m�: Sign: T _ • N Print: 111:5 / � / :*_ Print: pUWC-STATE OF FLORIDA MY COMM.EXP JULY 19,znb Seal: q•: , aed1tN+ •:o� Seal: ."`r COMMISSION AEE217905 BONDED THROUGH WESTERN SURETY CO. //11111111►N�� APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revisedo2/24/2014) L C7 N Z DRAWING INDEX !J Q �} Q 7 F_ 2 NUMBER TITLE .W J W A 0 TITLE PAGE z O U T H E Q 8 W 1 DRAWING LEGENDS NUW m M -Wj Q U A u toma tion • Energy Management • Ligh ting m ` Z 2 RISER DGRM/VALVE SCHEDULE ° �� 3 FLOOR 1 CONDUIT LAYOUT '•• o OPERATIONAL STANDARDS: • • • 4 FLOOR 2 CONDUIT LAYOUT 0000•• •••• 1. CONDUIT FILL-CONDUIT FILL IS DONE ON A POINT SYSTEM.Z"CONDUIT IS RATED AT 12 POINTS AND J"IS RATED AT 22. 000000 • �•••• EACH CONDUCTOR 18 GAUGE OR SMALLER IS TO BE COUNTED AS A POINT.CAT5 CABLE IS COUNTED AS 4 POINTS. THE 0066 • • • TOTAL NUMBER OF POINTS/CONDUCTORS SHALL NOT EXCEED THE MAXIMUM RATING OF THE CONDUIT. 5 M U LTY ZONE A H U DIAGRAM •0000 • • •••• •••• 2. LOW VOLTAGE STRAPPING-WHEN A LOW VOLTAGE CABLE IS INSTALLED NOT IN A CONDUIT OR FREE WIRED,THEY • • SHOULD BE SUPPORTED EVERY 6'. 000000 ••• •••• 3. ALL JUNCTION BOXES NEED TO BE ACCESSIBLE. ACCESSIBLE-CAPABLE OF BEING REMOVED OR EXPOSED WITHOUT g M U LTY ZONE A H U WIRING •••••• • ••• LL Co>••••• DAMAGING THE BUILDING STRUCTURE OR FINISH OR NOT PERMANENTLY CLOSE IN THE STRUCTURE OR FINISH OF THE Z<<c • BUILDING. MUST ALSO HAVE 2'OF CLEARANCE IN FRONT OF THE BOX. • < Q OW) • 4. GUTTERS-GUTTERS SHOULD BE INSTALLED WHERE MORE THAN 4 CONDUITS ENTER THE SAME SIDE ON THE 7 M U LTY ZONE A H U PARTS LIST • • • a LA••• ENCLOSURE. GUTTERS WILL BE INSTALLED WITH 2"CONDUIT NIPPLES BETWEEN GUTTER AND ENCLOSURE. • •••• ZZ� • 5. ENCLOSURES-CONDUIT SHOULD ENTER IN THE TOP AND BOTTOM OF THE ENCLOSURE. ALL 120V POWER SHOULD Ld •1.0•• ENTER IN THE BOTTOM RIGHT CORNER. 8 FAN COIL UNIT DIAGRAM •••• • •••1 00 5 • 6. LABELING-ALL WIRES ARE TO BE LABELED WITHIN 12"OF TERMINATION POINT WITH THE CORRECT ACRONYM. • • •p Froa WIRING FAN COIL UNIT WIRING W COLOR STANDARDS: ^ ANALOG OUTPUTS WIRE COLOR-TAN 3 WIRE ANALOG INPUT 10 VAV BOX DIAGRAM N2 WIRE COLOR-BLUE >- YEL DIGITAL OUTPUTS WIRE COLOR-PURPLE UP 2 WIRE DIGITAL OUTPUT BACNET-GREEN m ANALOG INPUTS WIRE COLOR-YELLOW LON-PINK TAN 3 WIRE ANALOG OUTPUT CITZ F DIGITAL INPUTS WIRE COLOR-ORANGE ORG 2 WIRE DIGITAL INPUT MODBUS-GREY JUN N y 201 �� Q INFINET-ORANGE J 1 WHITE CABLE CAN BE USED IF CORRECT COLOR IS NOT AVAILABLE. THE WHITE CABLE NEEDS TO BE MARKED WITH __=_�J CORRECT F COLOR TAPE WITHIN 12"OF TERMINATION. ALL MULTI-CONDUCTORS MUST ALSO BE MARKED WITH COLORED TAPE FOR EACH INPUT OR OUTPUT THEY HAVE. a` U CONTACTS: PROJECT SCOPE: PROJECT TITLE: 0 a a • 2 MULTY ZONE VAV AIR HANDLING UNITS ^ ' ` V W . 11 FAN COIL UNITS D . I N EZ AN D REAS N • 24 VARIABLE AIR VOLUME BOXES NEIL CAPORALS 3 EXHAUST FANS _ ROTH SOUTHEAST 2 LIGHTING CIRCUITS F �:F IT #: BUILDING OPERATIONS MANAGER • -- M ami Shcrgs Villa e (� PHONE: A7PRJ\JED BY DATE IS J p 954-423-6640 EXT 228 �- ?cNING DEPT - 11300 NW 2ND AVE 0 OG DEPT L lejz""f6' MIAMI, FL 33161 i!E^T 10 V MCE Wl rH ALL FEUER,AL rit�L_S )ULA s Z N M_ ACRONYM LEGEND: SYMBOL LEGEND: > � ACRONYM MEANING ACRONYM MEANING /� 0 C O NOTE NUMBER 1 BI9 r FAN FLOW METER z AC AIR CONDITIONER EPF ELEVATOR PRESSURIZATION FAN �J E I ¢i om AFMS AIR FLOW MEASURING STATION ERU ENERGY RECOVERY UNIT O LINE 1(HOT) PUMP Dp DIFFERENTIAL PRESSURE SENSOR w AHU AIR HANDLING UNIT FA FIRE ALARMO NEUTRAL(COMMON) COOLING COIL t DUCT STATIC PRESSURE SENSOR ¢- z Al ANALOG INPUT FPB FAN POWERED BOX 9 O THERMOSTAT DX COOLING COIL I FILTER SWITCH PRESSURE SENSOR n v w AO ANALOG OUTPUT FCU FAN COIL UNIT ® n >z v CARBON MONOXIDE SENSOR HEATING COIL ii AIR FLOW MONITORING STATION(AFMS) v c s z e o �a BMS BUILDING MANAGEMENT SYSTEM FD FIRE DAMPER i zoz •••• c o n� CO2 CARBON DIOXIDE SENSOR REHEAT COIL DAMPER • •< z a BTU BRITISH THERMAL UNIT FM FLOW METER • • •••• �J o 0 a•7 :• P$ PRESSURE SENSOR •••• • •••• `° • CFM CUBIC FEET PER MINUTE FSD FIRE/SMOKE DAMPER ® ELECTRIC DUCT HEATER ® ROOM SENSOR/THERMOSTAT • • • • 00 0 MOTOR STARTER • �• • CH CHILLER GEF GARAGE EXHAUST FAN DUCT MOUNT TEMPERATURE CONTROLLER ENCLOSURE •••••• • /HUMIDITY SENSOR �•• •• VARIABLE FREQUENCY DRIVE _ •••••• ••••0• m• • CHWP CHILL WATER PUMP GPM LOADING DOCK EXHAUST FAN VAV BOX 0000 • m00000 ' IMMERSION TEMPERATURE SENSOR (n to • • CHWV CHILL WATER VALVE GSF GARAGE SUPPLY FAN •••••• •••• W••:• • • • y.� •• •• ••••,W G7���•• CPF CHILLER PLANT EXHAUST FAN HP HEAT PUMP Za;p••. • • • CV CONSTANT VOLUME HX HEAT EXCHANGE WN• • ••••• N•o ••• l J Z • • • • •• Ci • CS CURRENT SWITCH LEF LOADING DOCK EXHAUST FAN •••• • • •• • • • om CT COOLING TOWER NTS NOT TO SCALE •• In p¢ Q m- CWP CONDENSER WATER PUMP OA OUTSIDE AIR > Z DDC DIRECT DIGITAL CONTROLS PSI POUNDS PER SQUARE INCH r DI DIGITAL INPUT RA RETURN AIR Q OD DO DIGITAL OUTPUT RF RETURN FAN F-e DP DIFFERENTIAL PRESSURE RTU ROOF TOP UNIT N O � 3 DPS DIFFERENTIAL PRESSURE SWITCH SA SUPPLY AIR DPT DIFFERENTIAL PRESSURE TRANSDUCER SCWP SECONDARY CONDENSER WATER PUMP F a EA EXHAUST AIR SF SUPPLY FAN d � t EEP EAST EJECTOR PUMP SP STATIC PRESSURE w o C Q EESC EAST ESCALATOR PUMP SPF STAIRWELL PRESSURIZATION FAN EESP EAST ELEVATOR SUMP PUMP TF TRANSFER FAN W EFSP EAST FIRE SUMP PUMP TXF TOILET EXHAUST FAN o EF EXHAUST FAN VAV VARIABLE AIR VOLUME EMS ENERGY MANAGEMENT SYSTEM VFD VARIABLE FREQUENCY DRIVE z 0 r a U N O W 0 M Z N N o L� n 2ND FLOOR w � B il EOL EOL ,�- > !- � � Z FX-POG2611-0 550 31 5501131 550-431 550.431 550-431 550-431 550-431 550-431 550-431 550-431 550-431 550-431 550-431 550-431 550-431 550-031 550-431 550-431 :-- - - 22 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 z Y NEW TRIDUIUM JACE BY JOHNSON CONTROLS TO AC-2 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 VAV-1 o BE PROVIDED BY ROTH SOUTHEAST. az v CLz n az GROUND FLOOR $ 11 FX-PCG2611-0 FX-PCG2611-0 FX-PCG2611-0 FXFCG2611-0 FX-PCG2611-0 FX-PGG2611-0 FX-PCG2611-0 FX-PCG2611-0 FX-PCG2611-0 FX-PCG2611-0 FX-PCG2611-0 FX-PCG2611-0 550-431 550-431 550-431 550-431 550-431 550-431 a M'-Wi¢ U 04 OS 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 4. �¢ z AC-1 FCU-1 FCU-2 FCU-3 FCU-4 FCU-5 FCU-6 FCU-7 FCU-8 FCU-9 FCU-10 FCU-11 VAV-2-1 VAV-2-2 VAV-2-3 VAV-2-4 VAV-2-5 VAV-2-6 •••• o.-u, • • .<..P,�2:U •••••• •• • W m••••• RISER PARTS LIST •••••• • LLI QTY PART# DESCRIPTION MANU. = Ll•••• • • •••••• V W 1 LP-FX3021 E-1 SUPERVISORY CONTROLLER JOHNSON •••••• 0000* •••••••• N �S��:o CONTROLS •••••• • Ld QSa•-• JOHNSON 1 LP-FXPMUS-0 WALL PLUG i • • • • > `IV Ylf>.• CONTROLS ••••••J w 04 J JOHNSON • • • Q W�" • 2 MS-BACEOL-0 END OF LINE TERMINATOR CONTROLS •••• i •• :•:� dpi • 1 X100CAA TRANSFORMER VERIS •• om �Ca y� 1 RET2620 ENCLOSURE KELE ' >^ Z 1 51012218 POWER RECEPTICAL KELE :3 Ld r L z w a in 9 U a 0 w VALVE SCHEDULE pC = PIPE VALVE FAIL BODY CLOSE FLOW VALVE DES DES VALVE CONTROL F UNIT QTY PART# CONFIG ACTUATOR TYPE �f SIZE SIZE POSITION CONFIG OFF (GPM) COEFF COEFF DELTA P DELTA P SIGNAL H NON-SPRING 200 P 2-10 O AC-2 1 PICCV-50-056 2" 2" 2-WAY RETURN THREAD PSI 53 ARX24-MFT ELEC VDC � � N NON-SPRING200 2-10 FCU-1 1 P207513100 3/4" 3/4" 2-WAY RETURN THREAD PSI 9.4 - LRX24-MFT ELEC VDC W 'o m RING 200 2-10 FCU-2 1 P207513100NONSP 100 3/4" 3/4" 2-WAY RETURN THREAD PSI 9.4 LRX24-MFT ELEC VDC a 2-10 FCU-3 1 P20758100 3/4" 3/4" 2-WAY NON-SPRING THREAD 200 9.4 LRX24-MFT ELEC VDC RETURN PSI VDC W ON-SPRING 200 2-10 p N FCU-4 1 P2075B100 3/4" 3/4" 2-WAY RETURN THREAD PSI 9.4 LRX24-MFT ELEC VDC FCU-5 1 P2075B100 3/4" 3/4" 2-WAY NON-SPRING RETURN RN THREAD PSS 9.4 LRX24-MFT ELEC 2-10 VD(,' FCU-6 1 P20758100 3/4" 3/4" 2-WAY NON-SPRING THREAD 200 9.4 LRX24-MFT ELEC 2-10 RETURN PSI VDC 2-10 FCU-7 1 P2075B100 3/4" 3/4" 2-WAY NON-SPRING THREAD PSI 9.4 LRX24-MFT ELEC VDC RETURN VD(�, NON-SPRING 200 2-10 FCU-8 1 P2075B100 3/4" 3/4" 2-WAY RETURN THREAD PSI 9.4 LRX24-MFT ELEC VDC p' ' a NON-SPRING 200 2-10 C' FCU-9 1 P20758100 3/4" 3/4" 2-WAY RETURN THREAD PSI 9.4 LRX24-MFT ELEC VDC w 0 NON-SPRING FCU-10 1 P20756RETURN 100 3/4" 3/4" 2-WAY THREAD PS2-10 I 9.4 LRX24-MFT ELEC VDC__ - W C .... I li7 I r , II If' i ( z N -- E E I - < M O — I i TO FCU I It -- - �--`- -- I--- _:_- I -----�-__--� S F FCU-8 �_...__.._ 0) Q I II � R � -' u i IL i w : � I.�- ---_- a ==moi------ -+ t R) ---CN I � I Q 2!. GG! M� W I FCU-6 9 a FCU-7 FCU 4 _J'— FCU-9 0 w ! I]�-b i_J 4b.6 ;~1 I, ®„.xrnb' ��,s•o.L - o v� a �1 o Z i . i I (_ �✓ i'I I i t I • 9Q.0 ww 4 E.G-GLfir 0000 t••• -- - h —1Z^ r - - - 3 I_I ti. •• • • 6w • � I I ! � j , ( 0000 •• • 100000 Fcz w FCU-8 FCU-3- u r FCU-10 • ,;.—,, I �3 0000•• 6 FCU-5 � ( � I � _ f jtk 0000•0 0*9 •• ;.�••!•� 0 II ��,i � I }. 0.00•• 0.00 Q @••.• — **6666 • W 00.900 0000• J ^••. _g� i ~ ate•• I , I � I � i Ijl �� III - ;y •••66• • Q • (7"y lisp �• FROM F U 4 r^ 1 - ,- �a� - - .uo o F - !H 9 t.Fah••• 1 �4C: •906••0 ✓ TO FCU-9 l �.• II' eusexak cu✓t. x r., • • • z 6 FCU-2; •• lr, g FCU-11 • • • O ' _ • •• • 'p Q I Ld f•LkWSf A"� oL \ � I �f sEnrrFA�r,aNs� - ! V �_ _ ! z ri ' IL 1\664 LA- I Tr'I- Jl— P6ctf+�? t1•EJ - I I ( 1 I ! •\\ - _q it '�' Qc 1arr0 I I, I N� -- -_ orW - -- -- - -- --- - _ - E F� a Li L©,,`irQ•rya t i_ `1:. _ 1 I - ,I _ - - -Aw ,' � -F; I W C c ki VAULT f=VAV-2-1 j'A /1 f QVWTRJOAL < i ROOM � I ©t P^Q +✓'G L_is 9'-0'h6aj R.'7• `S'1� F ..a. ,� A G ! Q • �.� ;- I � sr c - , i 0111�,{'(7Y°ee ua, --f B mG I A 1 I + �i ! —� Cc.f 1.4 2Go, C I I WAV-2-2 I II P -1-. tJc-. :a N 12 Ntti6 j A!orcc 7r}E klulr.tuw}eFy S67TcN4 09 VAv I 7q� R z TO AC-2 I �;o�t.r.F�ao-2 TO VAV-1- ?;vr�s s IaF cF rswu �y?wd TO AC-2 THE NC0.TcR'6ii.1 lu nW FvR r� FIRST FLOOR A/;C LAYOUT ➢!.N POMlEgL-D tA7�'Lt;a: 6WC5 j Iy.6p4Y{N �fEYr '('7. rrFE flJ7?' „8•'•,•.0• / 1_., f, �1B (15) 14) l3) `(m` � �O) l� � ,7� �6 5} W. C I I VLn I flp } - , I i N 0 q 4 r�ta� P1 9,a-i.IgceN K1,t.q-s35c, R� _ t` _ . ,__. ._ -- //��� _ — r w Liv •L I! �I- Q �! T lab i �� � LNIGISY��Ii•O'JYiYfIeGh'r,aTiOFICetGX7MG�-fia/�EAGa1-,u1(II! &Ig'1�G,�'6���a�}o.t�3.t-PH-�1�.�"°�.�?11)\`y��sr!'tI4-�G7Is.3'_ �-_13 4?p'��u��_9Ntr-6fs•�G,z�!; .-��SIIti-i� ��;�rila��i ae'lab..b.t:My-�I>II.:V;}µ1r1kFrer1,5iE�cir{vIrM:uY'Se ISc Iire.)I LP'L*'4d:Pr+Iz.S.roE 0 ,j/n ' s�,�j•: — .'1�II�.i'I�,'�.'._G-�-.,_w6sraucl4�etlsg-ra.e—`g 9FI.•V„tI'r(ti �2 VAV'l-1 XAV1-17 Kw a-1142M� .9.�2a.I i ,•i�'',I.It iAIa�42hO;V7af I'I NOTES: Lo O TYP FOR AC-1 AND AC-2 0 N z O REUSE EXISTING CHWI"' o VALVE FOR AC-1. o' u 0 > �- ce w o � z z 3y cm � 0 W Q� U Z O W RA CO2 .v .. XP-1 IN-1 a�.ai u G U CO-01 RATEMP RAHUMIDITY .v oy z INS YEL TE-03 0606•• c 0 ow T CO2 • • <; J z v 000 • • 0606•• poz 0 a•i•r •• • 0606•• _ W •.. pppp 0606••06•••• ••• •• •' x•006••. < 0000 0 0 < 0 RA 0 z 06 � •. • • 0606•••• m 3 > • � - •••• ••0606•• •06••00• 0000 Q W••0• • 01 Q 0606 0606 •00• ' sle"00. z<,D• HIGH STATIC DUCT STATIC :0606:•: • �_ aGM• FILTER STATUS IN 6 XP-1 IN-3 XP-1 IN-2 • • •00060 1061�,�• DPSA1 DPS-02 DPT-01 • • • Q �NI+-` • MATEMP -IIIA SATEMP • • • "t 06'06• OA DAMPER DMPR FEEDBACK IN_2 ORG WHT IN-1 YEL •• • •• :•: Z 10—m • OUT8 IN-5 TE-02 - TE-01 AE-01 AE-01 -F{- -.o. �- ""` •• • O >-o<M {{}{ YEL YEL WHT 000 :_H__..__5-- 000 ---. > F- z J � OA COP SA m or m m SA FAN SIB SA FAN VFD OUT1 I VFD-FD-01 U CHW VALVE VALVE FEEDBACK BACNET Q O OOUT9 IN-6 SA FAN STATUS COMM. /O U -01 Ii =< FIN-VIII- CS ?01 118-6 WHT �, X F S WHT yrs CAN -� � C `fir J '. O d ' a I 0 a c U N W a W C 130 VAC DEDIMED POWER 3/4-EMT FOR CONTROL WIRES COORDINATE WRH mm 15 RS 485 MS/TP NETWORK �a AMP FOSE e .< cE G COMMON 24VAC oo GROUR 6 B 5 m on SA FAN S/S ( RE-01 ) N® Lino xxe ®neL+ o xKe SA TEMP n LWOOO ( TE-01 J LNI G MA TEMP N m ( TE-02 ) LWO01 z Zino RA TEMP 201 ZNI ZW000 ( TE-03 ) • • • • • RA HUMIDITY 301 WoOIm0 m A Eino ( TE-03 ) 2D DMPR FEEDBACK ®neL+ EW000 x 30 ( AE-01 ) z £NIreli c m VALVE FEEDBACK x 20 303 I ®EWOOI y ( V-01 ) vNl O ®mool ®net+ SNI ®SWOOI m NI ®qV400IJ SA FAN STATUS IN] vino x SA FAN VFD ( CS-01 ) (VFD-01) FILTER STATUS Lw001 > m000 (DPS-01) A BNI { Sino O BW00I z SW000 ® c 91D0 ® m -D eW000 ® o G) Lino p ® n LW00C D m ®+ m eino 306 xx OA DAMPER 0 ® aO6 ( AE-01 ) ®- ® ® ® z eW000 0 ® ® � 0 308 an CHW VALVE ®WOO O 61n0 0 ® p ( V-01 ) 0A91. 6W000 0 ® ®+ ® ®. o WOO ®Woo n 0 ® 0 CIIHS ® lOH RA CO2 04 (CO-01 ) 304 LNI 0 DUCT STATIC 0 305 ®LWOOI x m (DPT-01) c n C�1 ZNI HIGH STATIC c • • • • (DPS-02) ®ZW00I m T ENI D m D mm c o rn EW001 7� m m m m m ®VNI ®vW001 '. n D 0 WOD m m x LEGEND ® + + G ® - INDICATES WIRING TO TERMINAL ® lOH ® - 24VAC HOT ® W00 WOO ® ?JMd ® - 24VAC NEUTRAL 0 OIHS 1. THE TERMINAL BLOCKS CAN BE RELOCATED ON THE SU13PANEL ACCORDING TO THE FIELD CONDITIONS. LABEL ALL TERMINAL BLOCK AND TERMINAL NUMBER. 2. PLEASE NOTE THAT THIS DIAGRAM IS FOR INFORMATIONAL UR PPOSES ONLY,AND DEPICTS ONLY HOW THE CONTROLLER IS TO BE TERMINATED, TO SEE THE CORRECT WAY TO TERMINATE A DEVICE REFER TO THE TERMINATIONS DETAILS. so so! so REV. DESCRIPTION DATE. APPROVED R T NM U LTY ZONE A H U WIRING FILE: Aodreas.dwg DRAWING _. � ■,0 ■ ■ JOB/CONTf) 30150017 DRWG i 6 .. BARRY UNIVERSITY 01 ME AN EIS•BLMVNQ ENGINEER MANAGER APPL NE DRAWN 11300 � 21D AT ••• • • SALES PROJECT ENGINEER M REV. 0 Il I J T H EAST MIAMI,•FL $3161• • • • • • «C NC NC TRK INIT DATE 4/23/15 Aulcn,ulbn EnrrgY Afanager enl•Lgh(i,qso SYMBOL QTY PART# DESCRIPTION MANU. SIGNAL RANGE ,n 2 FX-PCG2611-0 PROGRAMMABLE CONTROLLER JOHNSON M CONTROLS JOHNSON 2 FX-PCX3711-0 EXPANSION MODULE CONTROLS JOHNSON TE-01-02 4 TE-6311 M-1 DUCT MOUNT TEMP SENSOR CONTROLS 1 K OHMS NICKEL -50°F TO 220°F 0 DUCT MOUNT TEMP/HUMIDITY JOHNSON 1 K OHMS TE-03 2 HE-67N3-ONOOP SENSOR CONTROLS NICKEL, 0-10VDC 32°F TO 140°F,0-100% RH o z JOHNSON <> AE-01 2 M9208-GGC-3 ACTUATOR CONTROLS 0-1 OVDC MOUNT NORMALLY OPEN 0 RE-01 2 CKIT-VMD1B-F24 RELAY KIT VERIS 24 VAC COIL NORMALLY OPEN 2z U Z 2' CS-01 2 H608 CURRENT SWITCH VERIS DRY CONTACT NORMALLY OPEN W M >Q U DPT-01 2 PXUXX05S DIFFERENTIAL PRESS TRANSDUCER VERIS 0-5VDC 0-5"/WC � Z ` z U, _ 2 X100CAA TRANSFORMER VERIS . '..•.�`'�'Q • ••• •• • •••rte _ � • 2 CDE DUCT MOUNT CO2 SENSOR VERIS 0-5VDC 0-2000 PPM .. �.• •• •F— �•••••• z DPS-01 2 AFS-222 FILTER SWITCH KELE DRY CONTACT NORMALLY OPEN •••••• •••�.J ' DPS-02 2 AFS-460-DSS DIFFERENTIAL PRESSURE SWITCH KELE DRY CONTACT. 1.31"W.C-12.0"W.0(ADJ.) •••••• •••• ~ a""''� CONTACTS NC .•�..� �•...Q mt"e:• 10 2 51012218 POWER RECEPTICAL KELE """ ' Qa;n • • • CM No"00 SEE VALVE PRESSURE INDEPENDENT .• :•'•� = zo-j SCHEDULE CONTROL VALVE .. • •• < V-01 1 BELIMO • . cow •• � moa HMS O w� 1 �- z SEQUENCE OF OPERATION: m g m m SYSTEM WILL BE SCHEDULED BETWEEN OCCUPIED AND UNOCCUPIED BASED ON TIME OF DAY SCHEDULE. = U OCCUPIED: ® � ONCE IN THE OCCUPIED MODE THE SUPPLY SHALL START AND RUN F CONTINUOUSLY. THE SUPPLY FAN SHALL RAMP UP AND DOWN TO MAINTAIN . DUCT STATIC PRESSURE BETWEEN MIN 1"W.C.AND 1.5"W.C. THE DUCT STATIC CEO In PRESSURE SET POINT SHALL BE RESET BASED ON THE VAV DAMPER POSITIONS. __s THE CHILLED WATER VALVE SHALL MODULATE THE SUPPLY AIR SET POINT o BETWEEN 55°F AND 65°F SUPPLY AIR TEMPERATURE. THE SUPPLY AIR SET o' POINT SHALL BE RESET BASED ON THE AVERAGE ZONE TEMPERATURE OF THE VAVS. w IN THE OCCUPIED MODE THE OA DAMPER SHALL OPEN TO ITS MINIMUM POSITION o OF 30%(ADJ.).THE OA DAMPER SHALL MODULATE BETWEEN ITS MINIMUM POSITION AND ITS MAXIMUM POSITION (100%ADJ.)BASED ON CO2. THE CO2 SETPOINT SHALL BE 1100 PPM. SHOULD THE HIGH STATIC PRESSURE SETPOINT (4"W.C.)BE REACHED THE HIGH STATIC SWITCH SHALL SHUT THE AHU DOWN. UNOCCUPIED: IN THE UNOCCUPIED MODE THE OA DAMPER SHALL BE CLOSED AND THE AHU FAN AND ASSOCIATED EXHAUST FANS SHALL BE OFF.SHOULD THE AVERAGE U ZONE TEMPERATURE GO ABOVE 80°F THE AHU SHALL BE STARTED FOR 30MIN o MINIMUM UNTIL THE AVERAGE ZONE TEMPERATURE DROPS BELOW 78°F. SYMBOL QTY PART# DESCRIPTION MANU. SIGNAL RANGE NOTES' 11 FX-PCG2611-0 PROGRAMMABLE CONTROLLER JOHNSON O LIGHTING CIRCUITS TO BE CONTROLS JOHNSON WIRED TO FCU LOCATED IN z N TE-01-02 22 TE-6311M-1 DUCT MOUNT TEMP SENSOR CONTROLS 1 K OHMS NICKEL -50'F TO 220'F STUDENT LOUNGE. a00o TE-03 11 NS-BHP7001-0 ROOM TEMP AND HUMIDITY SENSOR JOHNSON 1K OHMS CONTROLS PLATINUM 32°F TO 104°F,0-100%RH C � O EXHAUST FAN TYP OF 1, TOJOHNSON _ AE-01 11 M9208-GGC-3 ACTUATOR CONTROLS 0-10VDC MOUNT NORMALLY OPEN BE WIRED TO FCU LOCATED fl c RE-01 11 CKIT-VMD1 B-F24 RELAY KIT VERIS 24 VAC COIL NORMALLY OPEN IN STUDENT LOUNGE ONLY. z CS-01 11 H608 CURRENT SWITCH VERIS DRY CONTACT NORMALLY OPEN �> G� 0 DPS-01 11 AFS-222 FILTER SWITCH KELE DRY CONTACT NORMALLY OPEN c -!W V-01 11 SEE VALVE PRESSURE INDEPENDENT BELIMO SCHEDULE CONTROL VALVE M:oz Z •••• < U WZ U EXH FAN S/S EXHFAN STATUS LIGHT CIRCUIT 1 ON/OFF LIGHT CIRCUIT 2 ON/OFF •" o¢— _ IN-5 OUT2 OUT3 OUT1 • • • " � � • RAI RE-02 RE-03 • •••••• _ •• RE-01 1 41— ••••••• •• • ••••• -w PUR PUR •••:.. • WHT ••••• •••• • • • FILTER STATUS •••••• •••i•�� � �••� IN-6 I • • • H NZM • RA TEMP O DPS-01 • • s• • •Zz c0•�••• IN-2 FAN S/S FAN STATUS ••• • �j4&0% TE-02 ORG OUT1 IN-5 SA i EMP • •. J qoQ OA DAMPER DMPR FEEDBACK � 0 RE-01 CS-01 EH HEAT TE 101 •• O N�� OUT8 IN-3 YEL OUT5 �_ U W C AE-01 AE-01 PO E"S FAN S/S comm. EH-01+H- YEL Z z OMM. H H _ L _ RE 01 �18-6 WHT WHT O O O < } ELECTRIC Kul HEAT m OA SA o L y C �W CHW VALVE VALVE FEEDBACK c ' SEQUENCE OF OPERATION: ours w a RJ-11 TO FCU V-01 I IV-01 HillQ FAN COIL UNIT WILL BE STARTED AND STOPPED BASED ON TIME OF DAY WHT < SCHEDULE. NC W OCCUPIED: O IN THE OCCUPIED MODE THE SUPPLY FAN SHALL RUN CONSTANTLY. THE OUTSIDE AIR DAMPER SHALL OPEN AND SHALL MODULATE FROM MINIMUM POSITION TO MAXIMUM POSITION TO TRACK THE SUPPLY FAN. THE UNIT SHALL HAVE A ZONE TEMP SET POINT OF 74°F FOR COOLING AND 68°F FOR HEATING. IN THE COOLING ZONE TEMP ZONE HUM MODE THE CHILLED WATER VALVE SHALL MODULATE FOR 55°F SUPPLY AIR SENSOR SENSOR TEMPERATURE AND THE VFD SHALL MODULATE TO MAINTAIN THE 74°F COOLING TE-03 I I TE-03 SETPOINT. IN THE HEATING MODE THE VFD SHALL BE SET AT A FIXED SPEED TO -*H PROVE THE AIRFLOW SWITCH AND THE ELECTRIC DUCT HEATER SHALL MODULE W TO MAINTAIN THE 68°F HEATING SET POINT. UNOCCUPIED: IN THE UNOCCUPIED MODE THE SUPPLY FAN SHALL BE OFF AND THE OA DAMPER SHALL BE CLOSED. W 2' 130 VAC OED—ED POWER D/9"EMx FO POL WIRES —RD—E WI1H DMSION 1 RS 985 N$/iP NEiWOPN---� m FUSE, ct COMMON 24VAC GR- CMO S R C ®' O SA FAN SIS m ( RE-01 ) xw e Lino MOz wwg v o LNI LWOoo SA TEMP LIGHTING CIRCUIT 1 ON/OFF ( TE-01 ) LWOol > 2100 ( RE-02 ) x B (R TE 02 P) ZNI { ZWOoo Oi ru g • • • • • o® Wool m - m m 6100 m m LIGHTING CIRCUIT 2 ON/OFF ®ASL+ EWOoo ( RE-03 I as g DMPR FEEDBACK ENI ? O Oma• a"g o• ( AE-01 ) A o ewool n VALVE FEEDBACK 0qNI ( V-01 ) L� mmol 0A91,+ ®SNI ®SWOOI ® W001 A FAN STATUS NI 4100 au SA FAN VFD S �'("SIT (VFD-01) FILTER STATUS LWO01 z bW000 (DPS-Ot) x SNI j 5100 ELECTRIC HEAT o 301 ( EH-01 ) BWOoI z SW000® 201 ZONE TEMP ® S 9100 ( TE-03 ) ZONE HUMIDITY m m 9W000 ( TE-03 ) ® 0 Lino p ® LW000 N D m ®+ N 8100 3O " OA DAMPER 0 ® z® ® ® ® BW000® an ( AE-01 ) 0 0 ® ®WOO ® ® G 6100 30 "" CHW VALVE 0 ® ®ASL 6W000 0 ® ®+ ® ®- woo ® W ®woo ® ® 0 ® ®0IHS ® lOH LE_GEN ® - INDICATES WIRING TO TERMINAL ® - 24VAC HOT ® - 24VAC NEU-RAL 1, THE TERMINAL BLOCKS CAN BE RELOCATED ON THE SUBPANEL ACCORDING TO THE FIELD CONDITIONS. LABEL ALL TERMINAL BLOCK AND TERMINAL NUMBER. 2. PLEASE NOTE THAT THIS DIAGRAM IS FOR INFORMATIONAL PURPOSES ONLY, AND DEPICTS ONLY HOW THE CONTROLLER IS TO BE TERMINATED. TO SEE THE CORRECT WAY TO TERMINATE A DEVICE REFER TO THE TERMINATIONS DETAILS. •• ••• •• Y • • •• •• • • • • • • •• • • REV DESCRIPTION DATE APPROVED i"4" •• • • • •• FILE:Andreas.dwg. .. DRAWING FAN c6r UNIT WIRING JOB/CONT # 30150017 ORWG 9 ROTH BARRY UNIVERSITY D. N ANJRE�AS.B I IN sA1,es PROJECT ADPL. DRAWN SII�R EMEINfER MANAGER!ENGINEER' BY: REV. O O U T H F A S T' 11300•@ & AE• • • • E„rrpyA4 gmrrvn.Lghuip MIAMI,•FL3316 ••• • • sNC NC NC TRK )(SIT ppTE 4/23/15 • •• •• • • • •• •• • NOTES: SYMBOL QTY PART# DESCRIPTION MANU. SIGNAL RANGE ,,, O ELECTRIC HEAT TYP FOR 13 24 550-431 VAV CONTROLLER SIEMENS VAV BOXES. z N o ROOM TEMP AND HUMIDITY SENSOR W/ TE-01 24 QAA3380.FWTC SIEMENS 10K PLATINUM 320 TO 122° F, 10-95% RH O EXHAUST FANS TYP OF 2, TO o SETPOINT AND OCCUPANCY OVERRIDE BE WIRED TO NEAREST VAV. d TE-02 24 QAM2030.020 DUCT MOUNT TEMP SENSOR SIEMENS NTC 10K -400 TO 240° F � La c w � G � RE-01 26 CKIT-VMD1B-F24 RELAY KIT VERIS 24 VAC COIL NORMALLY OPEN dr cm 0 CS-01 2 H608 CURRENT SWITCH VERIS DRY CONTACT NORMALLY OPEN RECD aza a-Z Z n < o w SA TEMP EXH FAN S/S EXHFAN STATUS o w AI-3 DO-4 DI-2 ;"',Oz z TE-02 RE-02 CS-01 a ii s ELECTRIC �I-YEL - ` z 1. WHT ••.. 9 o w� HEAT o00 .< QJ45 " .... o N�•s.�. • Z • 0 o CAT5E ....•. .. . ew 0 O CD o ,00:00 Z 0000• 0000 • 9' • 06 I • • •0000•• 0000 . M60:900 •0••• 0 •0.0•• 0.0••a :.:W 0000 - •• 00 0.00" � ' �0•• o LO .0.000 0 Q :aOM • HIrWW% ZONE TEMP ZONE HUM STPTADJ *OCC 6VRD�•••:'2 W,'j"_j • � Z ELEC HEAT STAT STAT STAT . .•.xp o .s•0 DO-3 TE-01 TE-01 TE-01 TE-01 •„• �D >-Ma RE-01 '0 CA 5E > L W^� -$-PUR _ _ > z SEQUENCE OF OPERATION: lPOWER AND TRANSFORMER AREE EXI EXISTING.REUSE. 3/4'EAR FOR CONTROL 4WRE5 r RS 485 MS/TP NETWORK Q - OCCUPANCY: THE VAV BOX WILL BE INDEXED TO THE OCCUPIED OR UNOCCUPIED MODE BY ITS ASSOCIATED AHU AND 0° LOCAL OCCUPANCY ENABLED, IF APPLICABLE. WHEN THE AHU IS IN OCCUPIED MODE AND THE LOCAL OCCUPANCY SENSOR IS ON, THE VAV BOX SHALL BE IN THE OCCUPIED MODE, OTHERWISE, THE VAV BOX SHALL BE IN THE F FDP s UNOCCUPIED MODE. O O ® u TEMPERATURE SETPOINTS: THERE SHALL BE SEPARATE SETPOINTS FOR COOLING, HEATING, OCCUPIED, AND UNOCCUPIED MODES. DURING THE UNOCCUPIED SCHEDULE, THE CONTROLLER SHALL INDEX THE ROOM TO A °R°DM°"° Oe EXH FAN SIS 2 PREDETERMINED ADJ. SETBACK HEATING-65°F/SETUP COOLING-80°F SETPOINT. DURING THE OCCUPIED PERIODS +O °” =a ( RE-01 ) Oz O (ADJ.) ( ) ( ) 0 G""""� 0 6 0<> I „„e ELEC HEAT THE SET POINTS SHALL BE 75°F COOLING AND 70°F HEATING. LIMITS OF +/-3°F (ADJ.) SHALL BE SET AT OPERATOR , 05 0 �oe ( RE-01 ) O s WORKSTATION FOR LOCAL OVERRIDE. 4 xz ° 0 'm;';O O O 3 1 EXH FAN STATUS O a VARIABLE AIR VOLUME: WHEN THE AIR TEMPERATURE EXCEEDS THE COOLING SETPOINT THE DAMPER SHALL ( cs-o� J 2 a MODULATE OPEN TO INCREASE AIRFLOW. UPON A FALL IN ROOM TEMPERATURE BELOW THE SETPOINT THE DAMPER Qo;, SA TEMP SHALL MODULATE TO A SCHEDULED MINIMUM VENTILATION VALUE. UPON A FURTHER DROP BELOW THE DEAD BAND ( TE-02 F GDM W (ADJ.)THE BOX AIRFLOW SHALL INDEX TO THE SCHEDULED MINIMUM HEATING CFM AND THE ELECTRIC HEATING COI ZONE <I SHALL BE ENERGIZED AND STAGED ON AND OFF TO MAINTAIN THE SPACE TEMPERATURE. ZONE w IE H i Z - HUM ( TE-01 ) UNOCCUPIED MODE: WHEN A SUFFICIENT NUMBER (ADJ) OF TERMINAL BOX SPACE TEMPERATURE SENSORS ARE SETPOINTADJ LO ( TE-0t BELOW/ABOVE THE UNOCCUPIED SETBACK/SETUP TEMPERATURE,THE AIR HANDLING UNIT SHALL BE STARTED,THE OATAPE HI Wn`H""S ro"^`" AMD OCC OVRD DAMPER SHALL REMAIN CLOSED AND INTERLOCKED EXHAUST FANS OFF. TEMPERATURE CONTROL SHALL BE AS ( TE-01 DESCRIBED ABOVE FOR THE SETBACK/SETUP TEMPERATURE SETTINGS. THE AHU SHALL BE RUN FOR A MINIMUM OF 15 MINUTES TO LIMIT STARTS TO FOUR PER HOUR. IF AN UNOCCUPIED MODE IS OVERRIDDEN, THE SYSTEM SHALL INDEX m-INDICATES WIRING TO TERMINAL ?' O+ o THE BOX AND AHU TO THE OCCUPIED CONTROL PARAMETERS FOR 2 HOURS(ADJ.). ® �`""`"°' ®-bVAC NEOTRAL O_ C U N W ALARMS: I. THE TERMINAL BLOCK$HE BE RELOCATED ON THE O A$USL_TERMINAL E MI ACCORDING TO THE FIELD NUMBER. . (ABEL 1. HIGH/LOW SPACE TEMPERATURE OCCUPIED MODE. A ERMIN LRE THAT AND OAGRL NUMBER. 2. HIGH/LOW SPACE TEMPERATURE UNOCCUPIED MODE. _. PBE NOTE THAT THIS CNGRAM IS FOR INEORM TIDN PURPOSES ONLY,AND DEPICTS ONLY HOW THE CONTROLLER 5 TO BE TERMINATED.TO SEE THE CORRECT WAY TERMINATE A DEVICE REFER TO THE TERMINATORSDIETAnS. 3. ELECTRIC HEAT ON-SPACE TEMPERATURE BELOW SET POINT. 4. DAMPER FULL OPEN-SPACE TEMPERATURE ABOVE SETPOINT. 5. DAMPER FULL CLOSED(OR AT MINIMUM)-SPACE TEMPERATURE BELOW SETPOINT. o: