Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-15-1340
5e°mss Miami Shores Village 10050 N.E.2nd Avenue NE \, Miami Shores,FL 33138-0000 r „ a Phone: (305)795-2204 �' y ... 5 �5, � } �"tarxivA � b r� Expiration: ) 2712015 Project Address Parcel Number Applicant 790 NE 97 Street 1132060142190 ANN VENO Miami Shores, FL 33138- Block: Lot: Owner Information Address Phone Cell ANN UENO 790 NE 97 Street (312)305-0095 s MIAMI SHORES FL 33183- Contractor(s) Phone Cell Phone Valuation: $ 7,000.00 BOWERS ROOFING INC (561)274-2896 (561)860-1461 _. ... Total Sq Feet: 1200 Type of Work:Re Roof Available Inspections: Additional Info:RE ROOF FLAT TO FLAT Inspection Type: Classification:Residential Tin Cap Scanning:4 Final Roof Roof in Progress Renailing Affidavit Review Roof Review Roof Review Roof Review Roof Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-6-15-55816 CCF $4.20 DBPR Fee $4.13 06/30/2015 Check#:2414 $756.46 $50.00 DCA Fee $4.13 06/03/2015 Check#:2382 $50.00 $0.00 Education Surcharge $1.40 Bond#:2771 Permit Fee-New Roof $275.00 Scanning Fee $12.00 Technology Fee $5.60 Total: $806.46 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRI ,PLUMBING, MECHANICAL,WINDOWS,DOORS, ROOFING and SWIMMING POOL work. OWNERS AF ID : I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructio and o ng. Futhermore, I authorize the above-named contractor to do the work stated. June 30, 2015 Au ed Signature:Owner / Applicant / Contractor / Agent Date Building Department Copy June 30, 2015 1 r � Miami Shores Village RD Building Department JUN o s 2015 1 I 10050L Miami Shores,Florida 33138 Te _ (305)795 2204 Fax:(305)756-8972 $Y' INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 2_0 JO BUILDING Master Permit No. ��" PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL F-1 PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑CANCELLATION ❑ SHOP wI C� CONTRACTOR DRAWINGS JOB ADDRESS: ? c1 O '`� ( -7� City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: ' { Flood Zone: BFE: FFE: OWNER:Name(Fee Simple Titleholder): Rtep\ lks A riN lf2N 0 Phone#: 3)2-305 0 o95 Address: -79® �f- 9 7 " �r City: r,.& ) A rA I 3k,),-,c, State: L— Zip: 33 139 Tenant/Lessee Name: Phone#: Email: Q [ q CONTRACTOR:Company Name: ��t3 W Q f 5 T`W� I rV c-, Phone#&6/ Address: I LJ O t-2,OlC�r'G. 1 �1�(%j C— City: r�5�l City: ,l rro"4 PAc-� `t'State: L-- Zip: 3 3 O fFt-c- 13 j)WMg Phone#: State Certification or Registration#:CC C 13 2 9 4 6$ Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ 7 0 4 O Square/Linear Footage of Work: l Type of Work: ❑ Addition ❑ Alteration ❑ New p �,Repair/Replace ❑ Demolition Description of Work: 1 c 4 Q(JL)G ft� -T-13 ` 1 Specify color thru tile: P fY color of Submittal Fee$ Permit Fee$ ��S - CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Flee-$ Structural Reviews$ Bond$ �� TOTAL FEE NOW DUE$ a S ? D t (Revised02/24/2014) :9 5 \) i3onding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES,BOILERS,HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature OWNER or AGENT CONT The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 9 day of P PieA 20 IS" ,by 9 day of A P +L- ,20 15 by L3 i� UEtaowho is personally known to ����� ►�wEi� s who is personally known to me or who has produced ��•• bA"Jews 4c-COS4 as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: n NOTARY PUBLIC: 4-2=cx-, Sign: Sign: Print: rv%. Print: c.. "�a e`' Vw- Seal: KATHLEEN M.BAKER Seal: •��a'" NotaryP �� KATHLEEN M. Public-State of Florida = Notar BAKER MY Comm:Expires Jut 28,2918 ,y y Public-State of Florida ,,, v•'r commis Expires I FF 1 SSi .,4� err My Comm.Expires Jut 28 9 APPROVED BY al Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) ----.- ?a..>1 W - . BOWERS ROOFING INC. 3100 S. FEDERAL Hwy., STE. C— DELRAY BEACH, FL 33483 Bowers Roofing Inc. PHONE: (561) 274-2896—FAX' (561) 274-2898 --- BROwARD (954) 418-4390 FAx(954)418-8755 LICENSE#CCC 1329468 Date: 3/23/2015 V 6-0v Customer Name: Ann Uno Residence Address: 790 NE 97th St., Miami Shores, Florida 33138 Email: ann.bennington@gmail.com Cell: 312-305-0095 91aA- vL, C s- Y It Project: Install new tile roof and new flat roof Bowers Roofing Inc. proposes to provide all the necessary material, labor and supervision for your roofing project. Included: 1. General Conditions: Temporary facilities, General Cleanup, supervision etc. 2. Scope of Work: A. Remove existing tile and flat roof B. Install 1 layer 30# felt per code C. Install 1 layer of Polystick TU Plus self-adhered underlayment. D. Install all tile with foam adhesive. E. Mix mortar with oxide to match tile per manufacturer. F. Cost is for a Boral Saxony 900 or equal. G. Install 1 layer GAF Liberty self-adhered base sheet on flat roof. H. Install 1 layer of GAF Liberty self-adhered cap sheet on flat roof. I. Replace all drip edge and plumbing flashings J. Permit Included K. Remove all debris from job site. NOTE: To upgrade to seal all joints in plywood before felt is installed with a self adhere membrane please add $785.00 Wood Work: First eight (8) sheets of plywood are free, thereafter, each sheet will cost $85.00 per sheet of plywood (if needed). Also included is 40 lineal feet of fascia board , each additional lineal foot will cost $6.00 3. Terms: A 33% due upon signing of contract. B. 33% due upon dry in. C. 33% due at completion. Page 1 4. a -rranty: There is a 10 year material warranty and a 10 (ten) year workmanship warranty from Bowers Roofing Inc. Warranties include any problem with roofing system that is from installation workmanship and excludes all natural calamities including debris from high winds or other falling objects such as trees and hail. Exclusions: 1. Any work not explicitly included above. 2. Impact fees. Base Cost: 1. Replace up to 120 tiles $1,200.00 r ^ �` 2. Replace upper (larger) flat roof $5,-900:Oa '127 �l � Our goal is to work closely with you in maintaining your budget and managing the construction process to produce a quality end product. IN Acceptance of Proposal: UV The above prices, specification and conditions are hereby accepted not accepted . With the acceptance of the above conditions and the price contractor and Owner shall enter a written contract. i' Homeowner Signature: Date: Authorized Signature: Date: Print Name: page 2 Jun, 2, 2015 11 ; 44AM No, 1430 P. 1 M 1 CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDONYYY) 6/2/2015 THIS CERTIFICATE 13 ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THis CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER, IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed, If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsemant s . PRODUCER I NAME:NTACT Chrl9tine Auman Frank H. Furman, Inc. PHONE (954)943-5050 FAIAJC, (954)84 -6310 1314 ?vast Atlantic Blvd. E-MAIL .christine@Yurmaninsurance.com P. O. Box 1927 INSURER(S)AFFORDING COVERAGE NAIC d Pompano Beach FL 33061 INSURERAArch Specialty Insurance 12119.9 INSURED INSURER 0: Bowers Roofing Inc IN URERC: 3100 South Federal Highway Suite C INSURER D: INSURER F; Delray Beach FL 33483 INSURER F' COVERAGES CERTIFICATE NUMBER:15/16 GL REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIE=S OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADOL ea PDLIC EFF FOLIC E P LTR TYPEOFIN5URANCE INSO WVD POLICY NUMBER M DD MM/DDlYYYY LIMITS X CONMVItIAL t3E lUiAL11ABILITY A CLAIMS-MADE �OCCUR EACH�OCCURRENCt: $ 1,000,000 P g S 100,000 AGL000964901 2/25/2015 2/25/2016 MEO EXP An one person) $ 10,000 PERSONAL&ADV INJURY 3 11000,000 GEN'L AGGREGATE LIMIT APPLIES PER: X POLICY❑PRO- GENERAL AGGREGATE $ 21000,000 JECT LOC PRODUCTS-COMP/OP AGO 3 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT S ANY AUTO BODILY INJURY(Per person) S AAS ED AUTOS BODILY INJURY(Per acddenl)NOWOS HIRED AUTOS AUTOS NED PROPER-TV-DAMAGE AUTOS6 i a UMBRELLA LIAR OCCUR EACH OCCURRENCE S EXcess LIAB CLAIMS-MADE AGGREGATE j DED RETENTION$ WORKERS COMPENSATION AND EMPLOYERS'LIABILITY PE /E%ECUTIVER OTH- ANY PROPRIETOR/PARTNERYIN I OFFICER/MEMBER EXCLUDE09 ❑ NIA E.L.EACH ACCIDENT $ (Mandatory In NH) E,L,DISEASE-EA<~ KOY6 S Ir yan atony I e unser DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ i DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Addlllonal Remarks Schedule,maybe allached Ir more apace Is required) L:Lcenae #CCC1329468 CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Miami Shores Village THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Avenue Miami Shores, 1:L 33138 AUTHORIZED REPRESENTATIVE Dirk DeLTong/KS � ,C,? ®1968-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD INS026 0ne401) ,SNORES G�! Miami Shores Village logo , ..,..M Building Department 10050 N.E.2nd Avenue re oRi Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: _ 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: -Am vi v- I? f-C� I/e*0 Property Address: 0 33 �� Roofing Permit Number: Dear!AuiingOfficial: 1_ 0 certify that I am not required to retrofit the roof to wall connections of my building ecause: ❑The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edi ' of the South Florida Building Code (1994 SFBC Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this .2 day of rykui KATHLEEN M.BAKER Notary Public•SM6 of florida =� • My Comm.Explres Jut n,'2918 Notary Public, Sate of Florida at Large f�-{ , �'� Commission•FF 137554 • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00,and the building was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5/21/2009 i ■ - . . a . . ■ - ■ - .-: • ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■ Raw■■aoc■se�■■�■■■■■■■■■■■■■■■■■■■ o . . . . . . . . .. .... .. . . . .. so ... • . : ;: : • . .• • .. . . . j . . . . --- Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, identify as"NA") C --jQ �} System Manufacturer: E ttyr P`1 1�1ep // l Field: u oc @ Lap,#Rows L( @ O "oc NOA No.: — I 0 O 3 ( ZPerimeter 0- -oc @ Lap,#Rows @ °oc Design Wind Pressures, From RAS 128 or Calculations: Corner: "oc @ Lap,#Rows�P� @ "oc Pmax1: Pmax2: Pmax3: Number of Fasteners Per Insulation Max. Design Pressure, From the Specific NOA Board System: (00 Q 5r Field: Perimeter Corner Deck: Type: P LY vl 0040 / Illustrate Components Noted and Gauge/Thickness: �/� Details as Applicable: Slope: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant r�h1�A�71c- Strip, Base Flashing, Counter- Flashing, Anchor/Base Sheet No.of Ply(s): Coping, Etc. I PLS/ y Indicate: Mean Roof Height, Parapet Height, Anchor/Base Sheet Fastener/ o ding Material: S Height of Base Flashing, Component Material, 1;1_4,4 . I a4 s w kt ,,s wJI /s J "n� S Material Thickness, Fastener Type, Fastener Insulation Base Layer: t A Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: ► 1A FT. Parapet Top Insulation Size and Thickness: 0C�� Height Top Insulation Fastener/Bonding Material: J U S� hI IOM L E v FT. Base Sheet(s)&No.of Ply(s): 4,A © L Mean Base Sheet Fastener/Bonding Material: Roof Height Ply Sheet(s)&No.of Ply(s): Ply Sheet Fastener/Bonding Material: •• ••• • • • •• Top Ply: T U"T) �Z— •• ••• .. . . .. Top Ply Fastener/Bongdin M teri% t'Ii • ... ... w . . G � .. .. • . Surfacing: RA-4 k •• •• w • • • • • • • • • • • •• •• • • • •• •• SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING } CONSIDERATIONS R4402.13.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner and the contractor.The owner's initial in the adjacent box indicates that the item has been explained. ✓�'' 1.Aesthetics-Workmanship:The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards.Aesthetics (appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. 2. Renailing Wood Decks:When replacing roofing,the existing wood roof deck may have to be r n filed in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to r m ving the existing roof system.) 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4.Exposed Ceilings: Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance,therefore, roofing nail penetrations of the underside of the decking may not be acceptable.This provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 46. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402,R4403 and R4413. 7.Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Exception:Attic spaces,designed by a Florida licensed engineer or registered architect to eliminate the attic ventin ,ventin shall not be required. 1 • •.. .1 A-� r's/Agent s Signature Bate•• tr:ga s gigure .. 0 0• •,; .. Property Address Permit AlurS�kS� • F i..fly�z-1 00r 3 13g .. ;M .. ... . ... . . . . ... . . ... .. .. . . . . . . . . ... . ..... ... . ... . . r r MAW MIAMI-DADE COUNTY PRODUCT CONTROL SECTION ® 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv CertainTeed Corporation(PA) 1400 Union Meeting Road Blue Bell,PA 19422 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of su h roduct or material within their jurisdiction. RER reserves the_nhttc revoke this acceptance if it is r% determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Flintlastic SA Roofing Systems Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA# 10-0330.02 and consists of a 1 throu 1 es p g g� 3. • The submitted documentation was reviewed by Alex Tigera. •• ••• • .. ... .. . . . .. . •t• • ... . . . . . . . . . . . . .,0110W •: :. • •: :. ': ;1�A No.: 15-0108.03 MIAW� "Expifation Date: 04/13/20 Approval Date: 04/09/15 ••• ... Page 1 of 13 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Material: SBS Deck Type: Wood Maximum Design Pressure -105 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic SA NailBase 66'6"x 39-3/8" ASTM D4601, Fiberglass reinforced, SBS modified bitumen Type II base sheet. Flintlastic SA Mid Ply 33'l I"x 39-3/8" ASTM D6164 Polyester and Fiberglass scrim reinforced, SBS modified ply sheet. Flintlastic SA P1yBase 39'-3/8"x 66'6" ASTM D1970 A self-adhering Fiber glass mat, SBS modified Flintlastic SA Cap 33'11"x 39-3/8" ASTM D6164 Polyester scrim reinforced, self-adhering SBS cap sheet. Flintlastic SA Cap FR 33'l I"x 39-3/8" ASTM D6163 Fiberglass scrim reinforced,self-adhering fire retardant SBS cap sheet. Flintlastic SA Cap CoolStar 33'l I"x 39-3/8" ASTM D6164 Polyester scrim reinforced, SBS cap sheet with a CoolStar coating. Flintlastic SA Cap FR 33'11"x 39-3/8" ASTM D6163 Fiberglass scrim reinforced,fire retardant SBS CoolStar cap sheet with a CoolStar coating. F1intPrime Asphalt 1,3 or 5 gal pail ASTM D 41 Asphalt primer. F1intPrime SA 1, 3 or 5 gal pail Proprietary Water based,polymer modified primer. .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . • " '11LOA No.: 15-0108.03 MIAMMADECOUNW "' ' "' ' "Expiration Date: 04/13/20 Approval Date:04/09/15 ••• ... Page 2 of 13 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . P � APPROVED INSULATIONS: TABLE 2 Manufacturer Product Product Description (with current NOA) F1intBoard ISO Polyisocyanurate insulation CertainTeed Corp. ACFoam 1I Polyisocyanurate insulation Atlas Roofing Corp. ENRGY 3 Polyisocyanurate insulation Johns Manville Multi-Max FA-3 Polyisocyanurate insulation R-Max,Inc. DensDeck,DensDeck Prime Gypsum coverboard Georgia Pacific H-Shield Polyisocyanurate insulation Hunter Panels Securock homogenous fiber reinforced U.S. Gypsum APPROVED FASTENERS: TABLE 3 Fastener Manufacturer Number Product Name Product Description (with current NOA) 1. Dekfast 14 with Dekfast Roofing screw with SFS Intec,Inc. Hex Plate hexagonal steel plate 2. Trufast#14 HD Fastener Roofing screw with 3"round Tru-Fast Corporation with Trufast 3"Metal steel plate Insulation Plate 3. Roofgrip#14 with Flat Roofing screw with 3" ITW Buildex Bottom Plate square steel plate 4. OMG Heavy Duty with 3 Roofing screw with 3"round OMG,Inc. in. Round Metal Plate steel plate 5. F1intFast#14 with F1intFast Roofing screw with 3"round CertainTeed 3"Insulation Plate steel plate 6. Dekfast 12 with Dekfast Roofing screw with SFS Intec, Inc. Hex Plate hexagonal steel plate .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . • •: :. •: :MOA No.: 15-0108.03 QMIUMAUM4bDADE COUNTY •• ••• 'Expiration Date: 04/13/20 Approval Date: 04/09/15 ••• ••• Page 3of 13 . . . . . . . . . . EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Underwriters Laboratories R11656 UL790 Annually Momentum Technologies,Inc. DX08C4A Physical Properties 03/22/04 DX20E3A Physical Properties 03/22/04 Factory Mutual Research 3009610 FM 4450 10/15/01 2D5A9.AM FM 4450 06/22/99 3014751 FM 4450 08/12/03 3014692 FM 4450 08/05/03 3012321 FM 4450 07/29/02 3008869 FM 4470 03/19/01 3037127 FM 4470 01/11/10 Exterior Research& 3518.12.03 TAS 114-F/G/I 12/01/03 Design,LLC 3519.12.03 TAS 114-D/J&TAS 117(B) 12/22/03 35~15 3., _.TAS I T 44a{$} _ 0.7p-Wa3 3521.07.04 TAS 114-J&TAS 117(B) 07/28/04 3522.07.04 TAS 114-D 07/28/04 Trinity ERD C31410.06.10 ASTM D 5147/4798 06/03/10 C7290.01.08 ASTM D 4601/1970 01/16/08 C8370.08.08-R1 TAS 114-H/J&TAS 117(B) 10/05/09 C8500SC.I 1.07-R1 ASTM D 6862/TAS 117(B) 08/07/09 C10080.09.08-R4 ASTM D 5147/6163/6164 03/25/10 ASTM D 6222/3909 C10080.09.10 ASTM D 5147&6163 09/01/10 PRI Construction Materials CTC-034-02-01 REV ASTM D 6163 11/24/08 Technologies .. ... . . . . . .. .. . . . . .. . . . . ... . . .. .... .. . . . .. . •.• . •.• . . 0 ' •• •• •+A No.: 15-0108.03 MIAMMADE COUNTY ••• 0-: ••Explration Date: 04/13/20 Approval Date:04/09/15 •.. ... Page 4 of 13 . . . . . . . . . . . .. .. 00 • •• •• ... . . . ... . . APPROVED ASSEMBLIES: Deck Type II: Wood,Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using 8d diameter ring shank nails. System Type A(1): Anchor sheet mechanically fastened,optional top layer adhered with approved adhesive All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' H-Shield Minimum 1.5"thick N/A N/A Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' DensDeck Minimum'/o"thick N/A N/A Note: Base insulation layer shall be adhered with TITESET Roofing Adhesive or WeatherTite One Step Foamable Adhesive spaced 4" o.c. Top layer of insulation shall be adhered with TITESET Roofing Adhesive or WeatherTite One Step Foamable Adhesive spaced 6"o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Anchor Sheet: One ply of All Weather/Empire Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c.at the 3"lap and 8"o.c.in three,equally spaced center rows. Primer: Apply Flint-Prime SA to DensDeck surface at 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA P1yBase, self-adhered. Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: None Maximum Design Pressure: -52.5 psf(See General Limitation#7.) .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . • ': :. '; ; 110A No.: 15-0108.03 CMM4&4HM:)ADEHC0j=U1?NMTY "' "' "Exp?ration Date: 04/13/20 Approval Date: 04/09/15 ••• ••. Page 5 of 13 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . f Deck Type II: Wood,Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c.using 8d diameter ring shank nails. System Type A(2): Anchor sheet mechanically fastened,optional top layer adhered with approved adhesive. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' H-Shield Minimum 1.5"thick N/A N/A Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' Securock Minimum 1/d'thick N/A N/A Note: Base insulation layer shall be adhered with TITESET Roofing Adhesive or Insta-Stick spaced 4" o.c. Top layer of insulation shall be adhered with TITESET Roofing Adhesive or Insta-Stick spaced 6" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Anchor Sheet: One ply of All Weather/Empire Base Sheet mechanically attached as detailed below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8"o.c.at the 3"lap and 8"o.c. in three, equally spaced center rows. Primer: Apply Flint-Prime SA to Securock surface at 0.3 gal/square. Base Sheet: One or more layers of Flintlastic SA PlyBase,self-adhered. Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: None Maximum Design Pressure: -60 psf(See General Limitation#7.) .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . •• . ••. . ••. . . . . . . . . . . . . • • • • • 00 0 0• •: :• • •: :140A No.: 15-0108.03 MIAMMADE COUNTY ••• • 006 • ••Expiration Date: 04/13/20 • Approval Date: 04/09/15 ••• ••• Page 6 of 13 ••• • • Y ••• • 0 Deck Type 1I: Wood,Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c.using 8d diameter ring shank nails. System Type C(1): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' FlintBoard,ACFoam II,ENRGY 3,Multi-Max FA-3,H-Shield Minimum 1.5"thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Top Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' Minimum 1/4"thick 1,2,3,4,5 1:1.33 ft' Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply F1intPrime SA to DensDeck surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA Mid Ply, self-adhered Ply Sheet: (Optional)One or more layer of Flintlastic SA Mid Ply, self-adhered Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap CoolStar self-adhered. Surfacing: None Maximum Design Pressure: -45 psf(See General Limitation#7.) .. ... . . . . . .. .. ... .. . . . .. . ... . ... . . . . . . . . . . . . • " •• • +)A No.: 15-0108.03 MAMMADE COUNTY "' ••• • ••Expfration Date: 04/13/20 Approval Date:04/09/15 ••• ... Page 7 of 13 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . Deck Type 1I: Wood, Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c.using 8d diameter ring shank nails. System Type C(2): All layers of insulation simultaneously attached. All General and System Limitations apply. One or more layers of any of the following insulations. Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft' FlintBoard,ACFoam II,ENRGY 3,Multi-Max FA-3,H-Shield Minimum 1.5"thick 6 1:1.45 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: Apply F1intPrime SA to insulation surface at 0.3 gal/square. Base Sheet: One or more layer of Flintlastic SA PlyBase, self-adhered. Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: None. Maximum Design Pressure: -60 psf(See General Limitation#7.) .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . ... . ... . . . . . . . . . . . . •' " jOA No.: 15-0108.03 MIAMEUADE COUNTY "' ' "' ' ••Expiration Date: 04/13/20 • Approval Date:04/09/15 ••• • ... Page 8 of 13 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . r � Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood attached using approved 8d nails spaced 6"o.c. at wood joists spaced max. 24"o.c. System Type E(1): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: (Optional)One or more layers of G1asBase,loose laid. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor/Base sheet shall be fastened with approved 11 gauge 1-1/4"annular ring-shank roofing nails and tin caps spaced 8"o.c. at the min. 3"wide side lap. With three additional(equally spaced)staggered rows in the center of the sheet spaced 8 inches o.c. for a total of four rows. Ply Sheet: (Optional)One or more layers of Flintlastic SA Mid Ply, self-adhered. Membrane: �„ s- - Onc aytr offiirrttastic~,9*C1ap,-Ffin a R;F int}ast c SA-eap_F lStar; Flintlastic SA Cap CoolStar self-adhered. Surfacing: None Maximum Design Pressure: -52.5 psf(See General Limitation#7.) .. .•. . . . . . •• . .. . . . . ... . as • -a- 09 . . ••• . ••• . . . . • . . . . . . . • • . . • • • • ': i• ' '; 'a • •; ;1tOA No.: 15-0108.03 MAMR ADE COUNTY *00 • 000 • ••Expiration Date: 04/13/20 Approval Date:04/09/15 ••• ••,, . Page 9of 13 • • • • • • • • • • Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood attached using approved 8d nails spaced 4"o.c.at wood joists spaced max. 24"o.c. System Type E(2): Base sheet mechanically fastened All General and System Limitations apply. Separation Sheet: (Optional)One or more layers of GlasBase,loose laid. Anchor/Base Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor/Base sheet shall be fastened with approved 11 gauge 1-1/4"annular ring-shank roofing nails and tin caps spaced 8"o.c. at the min. 3"wide side lap. With three additional (equally spaced) staggered rows in the center of the sheet spaced 8 inches o.c.for a total of four rows. Ply Sheet: (Optional)One or more layers of Flintlastic SA Mid Ply or SA P1yBase self-adhered. M.mbra Oric`Iaycr of-F3intiastic-6 Eapr;hnttastic S*Cap-FR,-F' tic SA-Ckp FR CoolStar; Flintlastic SA Cap CoolStar self-adhered. Surfacing: None. Maximum Design Pressure: -60 psf(See General Limitation#7.) .. ... . . . . . .. . .. . . . . ... . • • • • • • • • • • �: :• '; ;. '; ; P=OA No.: 15-0108.03 MIAMMADE COUNTY "' ' "' ' "Expiration Date: 04/13/20 Approval Date:04/09/15 ••• .•. Page 10 of 13 . . . . . . . . • • . .. .. . . . .. .. ... . . . .•. . . r ` Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24" spans attached 6"o.c.using#8 wood screws. System Type E(3): Base sheet mechanically fastened All General and System Limitations apply. Anchor Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 6"o.c.at the 3" lap and 6"o.c.in three, equally spaced center rows. Primer: None. Base Sheet: One or more layers of Flintlastic SA PlyBase,self-adhered. Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered.. - SnrPa ng: None_ Maximum Design Pressure: -75 psf(See General Limitation#7.) Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32'thick plywood at max 24"spans attached 6"o.c.using#8 wood screws. System Type E(4): Base sheet mechanically fastened. All General and System Limitations apply. Anchor Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4"o.c.at the 3" lap and 4"o.c. in four,equally spaced center rows for a total of five rows. Primer: None Base Sheet: One or more layers of Flintlastic SA PlyBase,self-adhered Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. Surfacing: None • • . Maximum Design •• •� .•� � � �•� • Pressure: - 105 psf(See General Limitation#7.) .. ... .. . . . .. 96, ... ... •� �• •: :. •: : PgOA No.: 15-0108.03 QMLEDADECOUNTY •"• " "•' ' '•Expiation Date: 04/13/20 • Approval Date: 04/09/15 ••• • • • • ••• • • Page 11 of 13 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • Deck Type 1: Wood,Non-Insulated Deck Description: Min 19/32"thick plywood at max 24"spans attached 6"o.c. using#8 wood screws. System Type E(5): Base sheet mechanically fastened All General and System Limitations apply. Anchor Sheet: One or more layers of Flintlastic SA NailBase,mechanically attached as described below. Fastening: Anchor sheet shall be fastened with OMG#12 with OMG Standard 3"metal plates spaced 8"o.c. at the 3"lap and 8 o.c. in two,equally spaced center rows Primer: Apply ASTM D41 primer to stress plates. Base Sheet: None Membrane: One layer of Flintlastic SA Cap,Flintlastic SA Cap FR,Flintlastic SA Cap FR CoolStar, Flintlastic SA Cap CoolStar self-adhered. sufffleingi. None.. Maximum Design Pressure: -82.5 psf(See General Limitation#7.) .. ... . . . . . .. 41 • .. . .. ... .. . . . .. . . . . . . . . . . ' •• • • •• • 10A No.: 15-0108.03 MIAMEUADE COUNTY ••• •• ••+ ••Expiration Date: 04/13/20 • Approval Date: 04/09/15 •.• • • • • •.• • Page 12 of 13 • • • • • • • • • • • •• •• • • • •• •• WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Smoot attached systems shall be limited to a maximum design ressure of-45 sf. H a. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 lbf.,as tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested, are below 275 lb£ insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect,or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters,and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE .. ... . . . . . .. . .. . . . . ... . . ... . ... . . . . . . . . . . . . ' • •• • • •• • 40A No.: 15-0108.03 MIAMMDADE COUNTY •• • •• :• •.Expiration Date: 04/13/20 Approval Date: 04/09/15 ••• • • • • ••• • • Page 13 of 13 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • era Phone 954-784-2941 800-848-1919 IMJA& TESTING INC. Fax 954-784-7875 250 SW 13th Ave Pompano Beach,FL 33069 fed-eng.com DATE: 6/22/15 Order No.: 15-1190 CLIENT: Bowers Roofing,Inc. ADDRESS: 3100 South Federal Hwa; Suite c; Delray Beach,FL 33483 PROJECT: Residence Flat Wood Deck ADDRESS: 790 NE 97th Street; Miami Shores,FL ASCE 7-10 DESIGN PRESSURE CALCULATIONS In Accordance with Chapter 30,Part I Proiect Information: Flat Wood Deck Height= 12' Exposure: C Ultimate Windspeed: V„It 175 mph Length= 40' Category: II Basic Windspeed: Va,d = 136 mph Width= 35' Slope: <7° KZ= 0.85 Parapet Wall: <3' Kd=0.85 KZt= 1.00 YY4• Design Calculations: • Velocity Pressure: q = 0.00256*[(0.85)(0.85)(1.00)(136)2] ...... .6.60. =34.2 psf 0.6.0• . .....• .... .. . .... . •. ..0.• Width of Pressure Coefficient: 0.1(35') = 3.5' . ...... . . ..... 0.4(12') = 4.8' } use: 3'6" 6 • .. .. .. .. ...... . Effective Wind Tributary Area: <10ft2 :. .000% .... 6 For parapet height 3 feet or larger,zone three(3)can be treated as zone two(2) (ASCE 7-10)! ;•; 0 .. . External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 Design Pressures: Zone 1 Field: P1 = 34.2*(-1.0 -0.18)= -40.4 psf Zone 2 Perimeter: P2 = 34.2*(-1.8 -0.18)= -67.7 psf Zone 3 Corners: P3 = 34.2*(-2.8 -0.18)= -101.9 psf Construction Material American Concrete Miami Dade Florida Department Engineering Council Institute County of Transportation s Page 2 6/22/15 Flat Wood Deck 790 NW 97`"Street Miami Shores,FL RAS 117 Design Pressure Calculations: Fastener Density /ft2 = 1:1.33 Fy = 59.85 lbs per fastener Attachment Requirements: Based on RAS-117 and N.O.A.#15-0108.03; with a design pressure of-45 psf, page 7 of 13,the following are our recommended insulation layer fastening requirements: Fasteners Per Insulation Board Insulation Board Zone 1 Field Zone 2 Perimeter Zone 3 Corners 4' x 4' 13 19 28 4' x 8' 25 37 55 Notes: Corners and perimeter area dimension shall not be less than a=3'6" 0000 All layers of insulation simultaneously mechanically fastened. •••• 0000.. All work shall be in compliance with the local building code.psoduct cbil;rol: ....:. notice of acceptance and manufacturer specifications and Floridw&alding Code0 • 000.. 2010 edition. 0"'•. :00 'a • 0000 0 00 00.04 . Wind load calculations based on ASCE 7-10 and information p�gvi�o by chf00 1it .. •6•••• . 00.0.0 . 0 All work shall be inspected by our field engineer or city imispector to r✓e!f . .0:0. .. . compliance with specifications. • • . . 0000.. •0 0 0 ..0 Sincerely, " Leith LeBlanc,P.E. Federal Engineering&Testing, Inc. / Florida Reg.No. 59394 Certificate of Authorization#5471 Miami-Dade County Certification#11-0407.01 edera Phone 954-784-2941 800-848-1919 LA&TESTING INC. Fax 954-784-7875 250 SW 13th Ave Pompano Beach,FL 33069 fed-eng.Com DATE: 6/29/15 Order No.: 15-1190 R CLIENT: Bowers Roofing,Inc. ADDRESS: 3100 South Federal Hwy; Suite c; DelrayBeach,FL 33483 PROJECT: Residence Flat Wood Deck ADDRESS: 790 NE 97th Street; Miami Shores,FL ASCE 7-10 DESIGN PRESSURE CALCULATIONS In Accordance with Chapter 30,Part I Proiect Information: Flat Wood Deck Height= 12' Exposure: C Ultimate Windspeed: V„it= 175 mph Length= 40' Category: II Basic Windspeed: Vasd = 136 mph Width= 35' Slope: <7° KZ= 0.85 Parapet Wall: <3' Kd=0.85 KZt= 1.00 . . .... ...... Design Calculations: ...... .. •••••• Velocity Pressure: q = 0.00256*[(0.85)(0.85)(1.00)(136) ] •••••• ;•• •• • =34.2 psf •••• •• ••••• ...... . .. ..... .. .. .... ...... Width of Pressure Coefficient: 0.1(35') = 3.5' •••••• •• 0.4(12') = 4.8' } use: 3'6" ••••;• Effective Wind Tributary Area: <1 OftZ •• •• • For parapet height 3 feet or larger,zone three(3)can be treated as zone two(2) (ASCE 7-10). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 DesiEn Pressures: Zone l Field: P1 = 34.2*(-1.0 -0.18)= -40.4 psf Zone 2 Perimeter: P2 = 34.2*(-1.8 -0.18)= -67.7 psf Zone 3 Corners: P3 = 34.2*(-2.8 -0.18)= -101.9 psf MIAWDMADE Construction Material American Concrete Miami Dade Florida Department Engineerinq Council Institute County of Transportation Page 2 6/29/15 Flat Wood Deck 790 NW 97th Street Miami Shores,FL RAS 117 Design Pressure Calculations: Net Width = 3.03 feet Net Length = 33.0 feet Side Lap Row = 49.5 fasteners/square Center Rows = 148.5 fasteners/square 0.51 ft2/fastener Fy = 30.3 lbs per fastener Base Sheet Attachment Requirements: Based on RAS-117 and N.O.A. #13-0129.16;page 10 of 13; the following are our recommended anchor / base sheet fastening requirements using approved 11 gauge 1 '/" annular ring shank roofing nails and tin caps: Zone 1 (Field): 8" o.c. @ laps and 3 staggered rows 8" o.c. •.••.' e•so:* Zone 2 (Perimeter): 6" o.c. @ laps and 3 staggered rows 6" o.c. • Zone 3 (Corners): 6" o.c. @ laps and 5 staggered rows 6" o.c. ""•' :....: sees • •e ••••e s...•e • •• sees• Notes: Corners and perimeter area dimension shall not be less than a=•�'¢�• '••. '. All work shall be in compliance with the local building cone product cl"s&. notice of acceptance and manufacturer specifications and Flom Btlding�olie. ••+• 2010 edition. • ; Wind load calculations based on ASCE 7-10 and information provided by client. All work shall be inspected by our field engineer or city inspector to verify compliance with specifications. Sincerely, lal zlef""�' Keith LeBlanc,P.E. Federal Engineering&Testing, Inc.6A 9� Florida Reg. No. 59394 Certificate of Authorization#5471 nliami-Dade County Certification#11-0407.01 TGFU.R11656 - Roofing Systems Page 1 of 37 F] UL Online Certifications Directory Home Quick Guide Contact Us UL.com TGFU.R11656 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems CERTAINTEED CORP R11656 ROOFING PRODUCTS GROUP 1400 UNION MEETING RD PO BOX 1100 BLUE BELL, PA 19422 USA 0000 Mineral Wool Felt, is a suitable alternate for perforated Type 15 asphalt organic felt in-the Class A,0 pr C roof..... constructions indicated below. •. • 000:00 .. . ..0 0 0. Type G 1 Flintglas Ply Sheet or Flintglas Premium Ply Sheet are suitable alternates for'rlle 15 organic felt; ;•••• Type G2 Glasbase Base Sheet is a suitable alternate for Type 15 and Type 30 base shecoVype G3'C�lidtglas • Mineral Surface Cap Sheet is a suitable alternate for Type 30 Cap Sheets. Flex-I-Glas,X=jum FCex-l-Glas or**:**. Flintlastic Base 20 Sheet is a suitable alternate for the G2 lass base and the Type All'1�1�dather p i YP 15 g /`� re bas•:•: sheet. 0000.. • 0000.. 0000.. Unless otherwise indicated, base sheets are mechanically fastened or spot mopped in place;•Fly anti cap sheets;•��„ .. ... are hot mopped in place. . Black Diamond base sheet is limited to noncombustible decks and combustible decks requiring insulation. Two plies Type G1 may be utilized in place of one ply Type G2. Flintlastic Ultra Glass SA is a suitable alternate for Type G2 Glasbase Base Sheet. "Black Diamond Base Sheet" is a suitable alternate for Type G2 Glass Base Sheet. "Flintlastic SA NailBase" or "Flintlastic SA PlyBase" are suitable alternates for Type G2 base sheets in Roofing Systems(TGFU)that limit cover applications to self-adhering ply/base sheets or membranes. EPS insulation followed by 1/2 in. cover board may be utilized in any of the following systems. The "YOSEMITE Venting Base Sheet" may be used in any of the following noncombustible deck roof systems and, where indicated, in combustible roof deck systems. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 2 of 37 "Torch APP" may be utilized in any of the following systems that contain "Flintlastic STA". APP Base T is a suitable alternate for any Type G2 base sheet. "Flintlastic Ultra Poly SMS" may be used in lieu of"Poly SMS Base" in all application Classifications. References to Type G2 base sheets includes "Channel-Vent GB". "FlintBoard Iso", "FlintBoard Iso Cold", "FlintBoard Iso-T" or "FlintBoard Iso Plus", may be used wherever polyisocyanurate insulation is specified. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. "FlintBoardH ISO", "FlintBoardH ISO Cold", "FlintBoardH ISO WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" and "FlintBoardH ISO DD" may be used wherever polyisocyanurate insulation is specified. "FlintBoardH ISO T", "FlintBoardH ISO T Cold" and "FlintBoardH ISO T WF" are acceptable alternatives to "FlintBoardH ISO", "FlintBoardH ISO WF" and "FlintBoardH ISO Cold", respectively, provided they do not exceed the indicated incline or thickness of the system. Any UL Classified EPS, any thickness, may be used below "FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", "FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO DD" insulation on non-combustible decks provided a minimum 1 in. thick layer of"FlintBoardH ISO", "FlintBoardH ISO T", "FlintBoardH ISO Cold", "FlintBoardH ISO T Cold", "FlintBoardH ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO F", "FlintBoardH ISO NB" or "FlintBoardH ISO DD" polyisocyanurate insulation is used. Max incline.MAIIbe in .. .. accordance with Classification established for the insulation/membrane roofing system,JbjA*oan not Z:*Med ..0*":' 1:12. • ...... .. 00 . ...... For Combustible Decks- Class A: •••• 0 00 ""•• .... . .. ..... 1. A minimum 3 in. layer or a minimum two layers of 1.5 in. of"FlintBoardH I10ZUd" or: •••••• "FlintBoardH ISO T Cold" is placed directly over a combustible deck and is cove vo.eVith anyllt Classified roofing membrane used in any UL Class A roofing assembly to achieLe I Gass A fire• •• Classification.As an alternative, any UL Classified insulation(except expande&or extruded polystyrene), any combination, any thickness, may be used below the 3 in. mini;ttam tiotal •.. :" thickness of"FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be leesely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified)may also be used below the insulation.All insulation joints must be staggered a minimum of 6 in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline can not exceed 1/2:12. 2. A minimum 1.9 in. layer of"FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold" is placed over a minimum 1 layer of Carlisle "FR Base Sheet IS" or Elk "VersaShield FB-IS" over a combustible deck. The insulation is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9 in. minimum total thickness of"FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier(non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.RI 1656 - Roofing Systems Page 3 of 37 with the Classification established for the membrane/insulation roofing assembly, however the incline can not exceed 1/2:12. For Combustible Decks- Class B: 1. A minimum 1.9 in. layer of"FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold", or a minimum 2 in. thick layer of Atlas "AC Foam III" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation(except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9 in. minimum thickness layer of"FlintBoardH ISO Cold" or "FlintBoardH ISO T Cold".The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier(non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline can not exceed 1/2:12. Unless otherwise indicated the following membranes are acceptable alternates for the following membranes tabulated below, limited to '/2 in. incline: Membrane Acceptable Alternate Flintglas Mineral-Surface Cap Flintglas Cap Sheet CoolStar Sheet Flintlastic GMS Premium Flintlastic Premium GMS CooJ$Ygr Flintlastic White Diamond GTA Flintlastic White Diamo;14 f''A Coo�_r *0'*:' Flintlastic GTS Flintlas;:;QT'S Cool%ar ...... Flintlastic Premium FR-P Flintlastic FR-Dual Cap or Flintlast 1emiC VR U "• Flintlastic FR Cap 30 T Flintlastic FR"T.30 Comtar Flexi las Premium Cap Sheet Flexi las PremiumCap $ eet�960 CooSar " Flintlastic GTA Flintlastic GTA CeolSta'r • Flintlastic GMS Flintlastic GMS CoolStar Flintlastic SA P-Cap FR Flintlastic SA FR Cap Sheet CoolStar Flintlastic GTA-FR Flintlastic GTA-FR CoolStar Flintlastic FR-P Flintlastic FR-Dual Cap or Flintlastic FR-P CoolStar Flintlastic FR-Cap 30 Flintlastic FR Cap 30 Sheet CoolStar ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT 00 G S PH A Class A 1. Deck: NC Incline: 3 file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 4 of 37 Base Sheet: —Type G2 Glasbase. Ply Sheet: —Type G1 Flintglas or Type G2 Glasbase. Surfacing: —Gravel or slag. 2. Deck: C-15/16* Incline: 1/2 *All joints blocked. Base Sheet: —Two layers Type G2 "Glasbase Base Sheet" or two layers Type G-1 "Flintglas Ply Sheet". Surfacing: —Type G3 "Flintglas Cap Sheet". 3. Deck: NC Incline: 3 Base Sheet: —Two layers Type 15 All Weather/Empire. Surfacing: —Gravel or slag. 4. Deck: NC Incline: 3 Insulation: —Polyisocyanurate, mechanically fastened or hot mopped, any thickness. Base Sheet: —Two to five plies Type 15 asphalt organic or Type G2 asphalt glass hot mopped. Surfacing: —Gravel. 5. Deck: C 15/32 Incline: 3 0696 Insulation: —Polyisocyanurate 1 in. min., mechanically fastened or hot mopped. •0000• ••0 0 Base Sheet: —Three plies Type 15 asphalt saturated organic felt(perforated) hot- opiped with 1wt 0• . . roofing asphalt. Surfacing: —Gravel. •••••• . 0000 0000.. 0000 . .. 0000. 6. Deck: C-15/32 Incline: 3 0 0 0 0 0 0 Vapor Retarder(Optional): —Type G2 "Glasbase" or UL Classified vapor rePa?&T. •� Insulation (Optional): —One or more layers or combination of the following:?oly1s0cya4w*4. ""'• perlite, glass fiber or wood fiber, any thickness. •0 0• ; Base Sheet: —Type G2 "Glasbase" base sheet. • Ply Sheets: —Two to three layers of Type G 1 "Flintglas" ply sheet or Type G-2 "Glasbase" base sheet. Surfacing: —Gravel or slag. 7. Deck: C-15/32 Incline: 3 Vapor Retarder(Optional): —Type G2 "Glasbase" or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber, any thickness. Membrane: —Three or four layers of Type G1 "Flintglas" ply sheet. Surfacing: —Gravel or slag. 8. Deck: C-15/32 Incline: 1 Vapor Retarder(Optional): —Type G2 "Glasbase" or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 5 of 37 perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2 "Glasbase Base Sheet" . Ply Sheets: —Two layers Type G 1 "Flintglas Ply Sheet". Cap Sheet: —One layer Type G3 "Flintglas Cap Sheet". 9. Deck: NC Incline: 1/2 Insulation (Optional): —One or more layers or combination of the following: Johns Manville "ENRGY 3", polyisocyanurate, perlite, glass fiber or wood fiber, any thickness. Base Sheet: —Two layers Type G2 "Glasbase Base Sheet" or two layers Type G1 "Flintglas Ply Sheet". Surfacing: —Type G3 "Flintglas Cap Sheet". 10. Deck: C-15/16* Incline: 1/2 *All joints blocked. Insulation (Optional): —One or more layers polyisocyanurate, 2 in. min, wood fiber, 1 in. min, perlite, 3/4 in. min, glass fiber, 15/16 in. min. Base Sheet: —Two layers Type G2 "Glasbase Base Sheet" or two layers Type G 1 "Flintglas Ply Sheet". Surfacing: —Type G3 "Flintglas Cap Sheet". 11. Deck: C-15/32 Incline: 3 Insulation (Optional): —Any thickness, one or more layers or combinations (optional of"Hy-Therm AP", "Hy-Therm TAPERED", "Hy-Therm COMPOSITE", "Celo-Therm""HY-Tec(Energy-LOk)", "TRI-Star", wood fiber or glass fiber, mechanically fastened or hot mopped. 1, •0 Base Sheet: —Type 15 asphalt organic felt, or "Glassbase Base Sheet", nailed ar�4ot mopped.*" ""'• Ply Sheets: —Min three plies Type 15 perforated asphalt organic felt, "Flintglas��VI P?*`wluql Ply• • Sheet", "Flintglas Type IV Ply Sheet", hot mopped. 000:60 • 0000 .. . . Surfacing: —Gravel or slag. 6 66666 0000 . .. 0000. 12.Deck:NC Incline: 2 0000.. • Insulation (Optional): —Any thickness, one or more layers or combinations(Optional) of;Vv Kherm.006:0 AP", "Hy-Therm TAPERED", "Hy-Therm COMPOSITE", "Celo-Therm", "HY:TecYEnergy-LOK)", ;...• wood fiber or glass fiber, mechanically fastened or hot mopped. 0' 6 • Base Sheet: —Type G2 "Glassbase Base Sheet", Type G1 "Flintglas Type VI Premium Ply Sheet" or "Flintglas Type IV Ply Sheet". Ply Sheet: —Min one ply Type G1, "Flintglas Type VI Premium Ply Sheet" or "Flintglas Type IV Ply Sheet", hot mopped. Surfacing: —Type G3 cap sheet, "Flintglas Cap Sheet", hot mopped. Class B 1. Deck: C-15/32 Incline: 1/2 Base Sheet: —Two layers Type 15 "All Weather/Empire Base Sheet". Surfacing: —Type G3 "Flintglas Cap Sheet". 2. Deck: C-15/32 Incline: 3/4 file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 6 of 37 Vapor Retarder(Optional): —Type G2 "Glasbase" or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2 "Glasbase Base Sheet". Ply Sheets: —One layer Type G1 "Flintglas Ply Sheet". Cap Sheet: —One layer Type G3 "Flintglas Cap Sheet". 3. Deck: NC Incline: 1 Insulation (Optional): —Isocyanurate, wood fiber, glass fiber, 2 in. max, mechanically fastened. Base Sheet: —One or more plies Type G2, hot mopped or mechanically fastened. Ply Sheet: —One or more plies Type G1, "Flintglas Ply Sheet Type IV" or"Flintglass Premium Ply Sheet Type VI", hot mopped or mechanically fastened. Membrane: —"Flintglas Cap Sheet", hot mopped. Class C 1. Deck: C 15/32 Incline: 1 Base Sheet: —Type G2 Glasbase. Ply Sheet: —Two layers Type G 1 "Flintglas". Surfacing: —Hot roofing asphalt, 20 lb/sq. 2. Deck: C-15/32 Incline: 1 Base Sheet: —Type G2 "Glasbase". 0000 Ply Sheet: —Two layers Type G 1 "Flintglas" or Type G2 "Glasbase". ••. 0000 •••••• Surfacing: —Hot roofing asphalt, 20 lbs/sq. ...... .. . ...... 3. Deck: NC Incline: 3 .•.. .. . .... . .. ..... Base Sheet: —Type G2 "Glasbase Base Sheet". „ •, �••� •••• Cap Sheet: —Type G3 "Flintglas Cap Sheet". • COAL TAR PITCH FELT SYSTEMS WITH HOT ROOFING COALoI`MsPITC-I 0 • .. 0 000 ...... Class A •• 1. Deck: C 15/32 Incline: 3 Insulation: —Polyisocyanurate, 1 min. mechanically fastened or hot mopped. Ply Sheet: —Four to five lies coal tar saturated organic felt or three lies of Type G-1 "Flintglas"p g p yp g ply sheet hot mopped with coal tar pitch or coal tar bitumen. Surfacing: —Gravel. 2. Deck: C-15/32 Incline: 1/2 Vapor Retarder(Optional): —Type G2 "Glasbase" or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: "Ultragard Premier", polyisocyanurate, perlite, glass fiber or wood fiber. Membrane: —Three or four layers of Type G1 "Flintglas" ply sheet. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 7 of 37 Surfacing: —Gravel or slag. COLD APPLICATION SYSTEMS Class A 1. Deck: C-15/32 Incline: 1 Vapor Retarder(Optional): —Type G2 glass base or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Johns Manville "U1traGard", polyisocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2 or G3 inverted. Ply Sheet: —Three layers Type G 1 or G2 "Glasbase" base sheet. Protective Coating: —Min 3 gal/sq Gardner Asphalt Corp. "Asbestos Free Emulsion Roof Coating (640)" or Gardner Asphalt Corp. "Nonfibered Emulsion Roof Coating" (042, 043), 9 gal/sq with 3 lbs chopped glass fiber. Emulsion and glass fiber are simultaneously sprayed from a special gun. Surfacing: —"Flintcoat A300" (fibered aluminum) or "FlintCoat-W," (white elastomeric) 1-1/2 gal/sq. 2.Deck: C-15/32 Incline: 1 Vapor Retarder(Optional): —Type G2 or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2. Ply Sheet: —Two layers Type G1 or G2. Protective Coating: —Min 9 gal/sq Gardner Asphalt Corp. Monoform Compound and 3 lbs.... Monoform glass fiber reinforcement sq. 000000 �••�• Surfacing: —"FlintCoat A300," (fibered aluminum) 1-1/2 gal/sq. 0000 0 3. Deck: NC Incline: 3 .... ...... .. Coating: —Two coats "FlintCoat-W," (white elastomeric) 1-1/3 gal/sq/coat. 0 0 0 0 •0... 4. Deck: C-15/32 Incline: 1 ' Vapor Retarder(Optional): —Type G2 glass base, Type G3 invented or UL C5ssitied va o=tctarder0��0+ Insulation (Optional): —One or more layers or combination of the following: Manville's "M P', polyisocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2 or Type G3 inverted. Ply Sheets: —Three layers Type G 1 or Type G2. Protective Coating: —Min 3 gals/sq of"FlintCoat-E." (fibered emulsion) 9 gal/sq with 3 lbs chopped glass fiber. Emulsion and glass fiber are sprayed simultaneously from a special gun. Surfacing: —"FlintCoat A300," (fibered aluminum) 1-1/2 gal/sq Base sheets are mechanically fastened to combustible decks. Base, ply and cap sheets are set in Fibrex Cement at 1-1/2 gal/sq.to noncombustible decks and between plies. 5. Deck: C-15/16* Incline: 1/2 *All joints blocked. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 8 of 37 Base Sheet: —One layer Type G2 "Glasbase Base Sheet" or Type G-1 "Flintglas Ply Sheet", mechanically fastened. Ply Sheet: —One layer Type G2 "Glasbase Base Sheet" or Type G-1 "Flintglas Ply Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. Surfacing: —Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. 6 Deck: C-15/32 Incline: 1/2 Vapor Retarder(Optional): —Type G2 "Glasbase Base Sheet" or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Poly isocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2 "Glasbase Base Sheet". Ply Sheets: —Two layers Type G 1 "Flintglas Ply Sheet", adhered with "FlintBond Brush Grade" at 1- 1/2 gal/sq. Cap Sheet: —One layer Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1- 1/2 gal/sq. 7. Deck: NC Incline: 1/2 Insulation (Optional): —One or more layers or combination of the following: Johns Manville "ENRGY 3", polyisocyanurate, perlite, glass fiber or wood fiber, any thickness. Base Sheet: —One layer Type G2 "Glasbase Base Sheet" or Type G1 "Flintglas Ply Sheet" Ply Sheet:—One layer Type G2 "Glasbase Base Sheet" or Type G1 "Flintglas Ply Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. Surfacing: —Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. 8. Deck: C-15/16* Incline: 1/2 • *All joints blocked. •••�•• .... ...... Insulation (Optional): —One or more layers polyisocyanurate, 2 in. min,woodfibr,'1 in.;n1*rk66erlite, ,, 3/4 in. min, glass fiber, 15/16 in. min. •••••• •• ..:..' Base Sheet: —One layer Type G2 "Glasbase Base Sheet" or Type GI "Flintgla?pl *Sheet"."'•• •••��• Ply Sheet: —One layer Type G2 Glasbase Base Sheet or Type G 1 Flintglas?1T et", adh8red with "FlintBond Brush Grade" at 1-1/2 gal/sq. Surfacing: —Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush (!We':at 1-1/; g4Vsq. 9. Deck: NC Incline: 3/4 Insulation (Optional): —Any thickness, one or more layers or combinations(optional)of"Hy-Therm Al"', "Hy-Therm TAPERED", "Hy-Therm COMPOSITE", "Celo-Therm", "HY-Tec (Energy-LOK)", wood fiber or glass fiber, mechanically fastened or hot mopped. Base Sheet: —Type G2 "Glasbase Base Sheet" or Type G 1 "Flintglas Ply Sheet". Ply Sheet: —Min one ply Type Gl, "Flintglas Ply Sheet", adhered with "FlintBond Brush Grade" at I- 1/2 gal/sq. Surfacing: —Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. Class B 1. Deck: C-15/32 Incline: 1 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. file:///D:/Documents/TGFU.R11656%20-%20Roofrng%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 9 of 37 Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer of Type G2 "Glasbase" base sheet. Ply Sheets: —One or Two layers of Type G 1 "Flintglas" ply sheet. Cap Sheet: —One layer of Type G3 "Flintglas Mineral Surface" cap sheet. 2. Deck: C-15/32 Incline: 1/2 Base Sheet: —One layer "All Weather/Empire Base Sheet", mechanically fastened. Ply Sheet: —One layer "All Weather/Empire Base Sheet", adhered with "FlintBond Brush Grade" at 1- 1/2 gal/sq Surfacing: —Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. 3. Deck: C-15/32 Incline: 1/2 Vapor Retarder(Optional): —Type G2 "Glasbase Base Sheet" or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber. Base Sheet: —One layer Type G2 "Glasbase Base Sheet", mechanically fastened or adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. Ply Sheets: —One layer Type G1 "Flintglas Ply Sheet, adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. Cap Sheet: —One layer Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1- 1/2 gal/sq. 4. Deck: NC Incline: 3/4 Insulation (Optional): —Isocyanurate, wood fiber, glass fiber, 2 in. max, mechdniaLy fastened'• ••••;• Base Sheet: —One or more plies Type G2, mechanically fastened or adhered with"F11ntBond 11fth •• Grade" at 1-1/2 gal/sq. 6 00 ' "•'•• Ply Sheet: —One or more plies Type G1, "Flintglas Ply Sheet", adhered with "Fl"t"ond BrjVh tirade":•••• at 1-1/2 gal/sq. '...•• , 0 00• 90000 Membrane: —Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush firadevat 14/2 gal/sq. ..:..' •• 00 .... 6000.0 Class C """ • • ...... ...... 1. Deck: NC Incline: 3/4 00 0 00 •••••• •0 Base Sheet: —Type G2 "Glasbase Base Sheet". Cap Sheet:—Type G3 "Flintglas Cap Sheet", adhered with "FlintBond Brush Grade" at 1-1/2 gal/sq. COMBINATION HOT AND COLD SYSTEMS Class A 1. Deck: C-15/32 Incline: 1 Vapor Barrier(Optional): —One ply Type G2, mechanically fastened or hot mopped. Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G1, hot mopped. Coating: —Gardner Asphalt Corp."Nonfibered Emulsion Roof Coating(042/043)", 9 gal/sq, min, 3 lb file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 10 of 37 glass fiber reinforcement. Surfacing(Optional): —"FlintCoat A300," (fibered aluminum) 1-1/2 gal/sq 2. Deck: NC Incline: 1 Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G 1, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G1, hot mopped. Coating: —Gardner Asphalt Corp. "Fibered Emulsion Roof Coating(740)" or Gardner Asphalt Corp. "Static Asphalt Fibered", 3 gal/sq. Surfacing: — "FlintCoat A300," (fibered aluminum) 1-1/2 gal/sq. 3. Deck: NC Incline: 1/2 Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G1, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G1, hot mopped. Surfacing: —"FlintCoat A300," (fibered aluminum) 2 gal/sq. 4. Deck: C-15/32 Incline: 1 Vapor Barrier(Optional):—One ply Type G2, mechanically fastened or hot mopped. Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G1, hot mopped. Coating: —"APOC 300 Plain Emulsion", 9 gal/sq, min, 3 Ib glass fiber reinforcement. Surfacing(Optional): —"FlintCoat A300", (fibered aluminum) 1-1/2 gal/sq •••• . . .... ...... 5. Deck: NC Incline: 1 • ...... .. . ...... Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any:ho et ltness. :•. •. • Base Sheet: —One ply Type G-1, mechanically fastened or hot mopped. "" •. ...... . .. ..... Ply Sheet: —Two or more plies Type G-1, hot mopped. • .. .. .... ...... Coating: —" FlintCoat-E," (fibered emulsion) 3 gal/sq. • Surfacing: FlintCoat A300," (fibered aluminum) 1-1/2 gal/sq. •. •••�;• • . Deck: NC Incline: 1 .. ... Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G-1, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G-1, hot mopped. Surfacing: — " FlintCoat-E," (fibered emulsion) 3 gal/sq. Class B 1. Deck: C-15/32 Incline: 1 Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G 1, hot mopped. Coating: —Gardner Asphalt Corp. "Fibered Emulsion Roof Coating (740)", 3 gal/sq. Surfacing: —"FlintCoat A300," (fibered aluminum) 2 gal/sq. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 11 of 37 2. Deck: C-15/32 Incline: 1 Base Sheet: —One ply Type G-2, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G-1, hot mopped. Surfacing: —" F1intCoat-E," (fibered emulsion) 3 gal/sq. 3. Deck: C-15/32 Incline: 1 Base Sheet: —One ply Type G-2, mechanically fastened or hot mopped. Ply Sheet: —Two or more plies Type G-1, hot mopped. Coating: —" FlintCoat-E," (fibered emulsion) 3 gal/sq. Surfacing: —" F1intCoat A300," (fibered aluminum) 2 gal/sq. MAINTENANCE AND REPAIR SYSTEMS Class A,B or C 1. Deck: NC Incline: 3 Existing Roof System: —Class A, B or C covered with: Insulation: —Polyisocyanurate, nailed or secured with hot roofing asphalt, coal tar pitch or coal tar bitumen. Base Sheet: —Asphalt organic, asphalt glass fiber, coal tar felt or asphalt organic/glass fiber ply sheet combination, hot mopped. Surfacing: —Gravel. Class A •••• . . 0000 0000.. 1. Deck: C-15/32 Incline•• 3/4 • 0000.. 0000.. Existing Roof System: —Class A, B or C (gravel may be removed) covered with:"". • Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet, Type G3 "Flintglas MinerarSu'rface" *0:"0 • • 0•• . 00 00000 cap sheet inverted or UL Classified vapor retarder. • • Insulation (Optional): —One or more layers or combination of the following: Pal ms anuratgJ erlite 6069:6••• glass fiber or wood fiber insulation. • . . Base Sheet: —One layer of Type G2 "Glasbase" base sheet or Type G3 "Flint 1 eral Surface" ca • Y YP YP s g $• ... •�� P ....� sheet inverted. Membrane: —One layer of"Flintlastic GTA, GTS" (modified bitumen), heat fused or "Flintla'stic' GMS" hot mopped. Surfacing: —APOC "No. 212 Fibrated Aluminum" at 1 and 1/2 gal/sq. 2. Deck: NC Incline: 1 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet, Type G3 "Flintglas Mineral Surface cap sheet inverted or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —One layer of Type G2 "Glasbase" base sheet or Type G3 "Flintglas Mineral Surface cap sheet inverted. Membrane: —One layer of"Flintlastic GTA (-3/4 sq or A sq), GTS" (modified bitumen), heat fused or "Flintlastic GMS" hot mopped. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 12 of 37 Surfacing: —APOC "No. 212 Fibrated Aluminum" at 1 and 1/2 gal/sq. 3. Deck: C-15/32 Incline: 1 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet, Type G3 "Flintglas Mineral Surface" cap sheet inverted or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —One layer of Type G2 "Glasbase" base sheet or Type G3 "Flintglas Mineral Surface" cap sheet inverted. Membrane: —One layer of"Flintlastic GTA(-3/4 sq or-1 sq), GTS" (modified bitumen), heat fused or "Flintlastic GMS" hot mopped. Surfacing: —Karnak "No. 97 Fibrated Aluminum" at 1 and 1/2 gal/sq. 4. Deck: C-15/32 Incline: 3/4 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Vapor Retarder(Optional): —Type G2 "Glasbase", Type G3 "Flintglas Cap" inverted or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Manville's Polyisocyanurate, perlite glass fiber or wood fiber insulation. Base Sheet: —One layer of Type G2 "Glasbase" or Type G3 "Flintglas Cap" inverted. Membrane: —One layer of"Flintlastic GTA, GTS, STA" (modified bitumen), heat fused or "Flintlastic GMS" hot mopped. Surfacing: —Karnak Chemical "No. 97 Fibrated Aluminum" at 1-1/2 gal/sq. 0 0 0. 5. Deck: NC Incline: 3/4 0 0 0 0 0.. 000 0000 . 0 0 0 0 0000. .. . 0000.. Existing Roof System: —Class A, B or C (gravel may be removed) covered wit +0:0 0 0 0 0 Insulation (Optional): —Perlite, wood fiber, fiber glass or polyisocyanurate, hot jvpp ped or, 0 :••••: 0 mechanically fastened. 0060* 0 000 *0000 Base Sheet: —Asphalt organic, asphalt glass fiber, "Yosemite Venting Base ShMV+ %jay be•invected), 0.:0 0' coal tar felt or asphalt organic/glass fiber combination, hot mopped. 0. 00 0:00* ••.0.0 Membrane: —One layer "Flintlastic FR", "Flintlastic FR Cap 30", "Flintlastic 1140 lJn FR-P"br "Flintlastic FR-Dual Cap", GMS, GTA, GTS, STA(coating on "FR" is optional)9 0 :000:0 Surfacing: —Karnak "No. 97" or"No. 98 AF" at 1-1/2 gal/sq. 0 :•0 0 0: .. . 0 000 0 0 6. Deck: C-15/32 Incline: 1/2 Existing Roof System: —Class A or B (gravel may be removed) covered with: Vapor Retarder(Optional): —Type G2 "GlasBase", Type G3 "Flintglas Cap" inverted or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Johns Manville"U ltraGard Premier", polyisocyanurate, perlite glass fiber or wood fiber insulation. Base Sheet: —One layer Type G2 "Glasbase" or Type G3 "Flintglas Cap" inverted. Membrane: —One layer "Flintlastic GTA FR" (modified bitumen), heat fused. 7. Deck: C-15/32 Incline: 3/4 Existing Roof System: —Class A, B or C (gravel may be removed)covered with: Vapor Retarder(Optional): —One ply Type G2, mechanically fastened or hot mopped. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 13 of 37 . Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Membrane: —"Flintlastic GTA or GTS", heat fused or"Flintglas GMS" (modified bitumen), hot mopped. Surfacing: —"APOC 212 AF Aluminum Fibre Roof Coating", 1-1/2 gal/sq. 8. Deck: NC Incline: 1 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Vapor Retarder(Optional): —One ply Type G2, mechanically fastened or hot mopped. Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Membrane: —"Flintlastic GTA or GTS", heat fused or "Flintglas GMS" (modified bitumen), hot mopped. Surfacing: —"APOC 212 AF Aluminum Fiber Roof Coating", 1-1/2 gal/sq. 9. Deck: C-15/32 Incline: 3/4 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Vapor Retarder(Optional): —One ply Type G2, mechanically fastened or hot mopped. Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Membrane: —CertainTeed "Flintlastic GTA or GTS", heat fused or"Flintlastic GMS" (modified bitumen), hot mopped. Surfacing: —"F1intCoat A300," (fibered aluminum) 1-1/2 gal/sq. 10. Deck: NC Incline: 1 . . 0000 0000.. Existing Roof System: —Class A, B or C (gravel may be removed) covered with? .. . 0000.. Vapor Retarder(Optional): —One ply Type G2, mechanically fastened or hot 0000..mgQ��d. Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. .. ;:0000: 0000 Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. 000000 ' '..' ..�..0 i Membrane: —CertainTeed "Flintlastic GTA or GTS", heat fused or "Flintlastic Ot9'.4(modif ed� ..... bitumen), hot mopped. •• •• 6666 000000 Surfacing: —"F1intCoat A300," (fibered aluminum) 1-1/2 gal/sq. :":': • . . . . 6060% 0000.. 0 11. Deck: C 15/32 Incline: 1/2 Impact: 4 '0 0 00* 0"'•0 0 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Insulation (Optional): —Any UL Classified, any thickness. Underlayment Board: —One layer 1/4 in. thick min. G-P Gypsum "DensDeck®, mechanically fastened. Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened or one layer "Flintlastic SA P1yBase", self-adhered to primed "DensDeckO" or DensDeck Prime, only. Cap Sheet: —One layer "Flintlastic SA P-Cap FR", self-adhered. 12. Deck: NC Incline: 1 Existing Roof System: —Class A, B or C (gravel may be removed) covered with: Insulation: —Any UL Classified polyisocyanurate, wood fiber, glass fiber, or perlite, any thickness, mechanically fastened. Base Sheet: —"Flintlastic Base 20 T", heat welded. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 14 of 37 Membrane: —"Flintlastic FR Cap 30 T", heat welded. 13. Deck: NC Incline: 1 Existing Roof System:—Class A, B or C (gravel may be removed) covered with: Vapor Retarder: —One ply Type G2, mechanically fastened or hot mopped. Insulation (Optional): —Any UL Classified polyisocyanurate, wood fiber, glass fiber, or perlite, any thickness, mechanically fastened. Base Sheet: —"Flintlastic Base 20 T", heat welded. Membrane: —"Flintlastic FR Cap 30 T", heat welded. SINGLE PLY MEMBRANE SYSTEMS (MODIFIED BITUMEN) Henry "MBA Gold Adhesive", "Henry No. 200" or "HE#902 Permanent Bond Adhesive" adhesive may be used in any of the following "Flintlastic FR" or "GMS" Single Ply Membrane Systems when applied at a max of 3 gal/sq. Unless otherwise indicated, any of the following Single Ply Membrane Systems may utilize multiple layers of "Flintlastic" or "Poly SMS"membrane as an optional mid-ply. Unless otherwise indicated any of the following Single Ply Membrane Systems may utilize the addition of a G1 "Black Diamond Base Sheet", "Flintglas Ply Sheet", "Flintglas Premium Ply Sheet" or "Stormshield". 1/2 in. thick (min) gypsum board or 1/4 in. thick(min) G-P Gypsum DensDeck®may be used in any existing noncombustible deck Classification. When this is done,the resulting roofing system is acceptable for use over combustible(15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. The board and "DensDeck®" must overlay any polystyrene. 0000 0 '00000 0000.. "Flintlastic Ultra Poly SMS" or"Poly SMS" may be utilized in lieu of any Type G2 bassr►'ee>f in any.ofthe following noncombustible roof deck systems. 0000.. 0000.. The addition of either a Type G or Type G2 base or ply sheet may be added any of the.folfowing rabf systems. '. ' .000 . 00 •••.• .. .. 0000 0000.. The following coatings may be used over the "Flintlastic STA", "Flintlastic STA Plus",:'CsIEA", "GTA 81ack Diamond" and "GTA White Diamond" membranes (max incline is limited to 1/2 in., noncom;ustible decks .... • only): 0000.. A. Tropical Asphalt "120 AF", applied at 1-1/2 gal/sq. B. Karnak "No. 97 AF", applied at 1-1/2 gal/sq. C. Henry "Nos. 520, 521 ", applied at 1-1/2 gal/sq. D. Grundy Industries "A1MB Al"', applied at 1-1/2 gal/sq. E. Monsey "Premium Long Life Aluminum", applied at 1-1/2 gal/sq. F. Monsey "Fibered Asphalt Emulsion", applied at 3 gal/sq. G. Henry "No. 107 Emulsion", applied at 3 gal/sq. H. Henry "No. 220 AlumiTop Roof Coating", at 1-1/2 gal/sq. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 15 of 37 I. Henry "No. 229 Aluminum Emulsion Roof Coating", at 1-1/2 gal/sq. Unless otherwise indicated "Flintlastic Base 20 T" (only heat fused)may be utilized in lieu of"Flintlastic Base 20" in any of the following roofing systems. Unless otherwise indicated "Flintlastic FR Cap 30 T" (only heat fused) may be utilized in lieu of"Flintlastic FR-Cap 30" in any of the following roofing systems. United Solar Ovonic LLC's Field-Assembled Photovoltaic (Solar) Module Systems "PVL-29, -31, -58, -60, - 62, -64, -68, -87, -93, -116, -120, -124, -128, -136, -144" may be installed over any UL Classified CertainTeed modified bitumen roofing system. The Module system is adhered directly to the roofing membrane in the field using either: (1) CIM 162 Adhesive, applied at 2.18 to 3.12 gal/sq; (2)NPC "#900 Solar Seal" (not UL Classified), applied in a bead around the perimeter of the photovoltaic modules; or(3) Henkel "PL Polyurethane Roof&Flashing Sealant" (not UL Classified), applied in a bead around the perimeter of the photovoltaic modules. The Classification applies to combustible and non-combustible decks. The maximum incline and Classification(Class A, B or C) shall be in accordance with the Classification established for the membrane roofing assembly. However, for the CIM 162 Adhesive, the incline cannot exceed 1-1/2:12 for Class A and 2:12 for Class B. For the NPC "#900 Solar Seal" and Henkel "PL Polyurethane Roof& Flashing Sealant", the incline cannot exceed 2-1/2:12 for Class A. OTHER SYSTEMS Class C 1. Deck: C-3/8 Incline: Unlimited "EnerGen" system consisting of the following: •••• . . .... ...... Base Sheet: —One layer of Type 15 felt, mechanically fastened. •• •••• Ply Sheet: —One layer of any UL Classified TPO, mechanically fastened. •••••• •• •••••• Building Unit: —Unisolar PVL" series, self adhered (15-1/2 in, wide PV Laminal'es separated by :....: aluminum "T's" running up-slope) or PowerMembrane. . .... . .. ..... . .. ..... 2. Deck: C-3/8 Incline: Unlimited •• •• 0000 0090.0 00 0000.. . . . "EnerGen" system consisting of the following: . ...... 00000 0 .. ... Base Sheet: —One layer "PVLayment, self-adhered. Building Unit: —Unisolar PVL" series, self-adhered(15-1/2 in, wide PV Laminates separated by aluminum "T's" running up-slope)or PowerMembrane. Class A-Ballasted 1. Deck: C 15/32* Incline: 1/4 *All joints blocked with 2 x 4's. Base Sheet: —Type G2 "Glasbase" base sheet, nailed. Insulation: —Polyisocyanurate, perlite or glass fiber, 1 to 1-1/2 in. Ply Sheet: —One layer Type G2 "Glasbase" base sheet, hot mopped. Membrane: —One layer "Flintlastic GTA(-3/4 sq or-1 sq), GTS, STA." (modified bitumen), heat fused or "Flintlastic GMS", hot mopped. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 16 of 37 Surfacing: —Gravel, 400 lbs/sq, (may be applied loose or in hot roofing asphalt). 2. Deck: NC Incline: 2 Insulation: —Polyisocyanurate, mechanically fastened or hot mopped. Membrane: —Any UL Classified. Surfacing: —River bottom stone, 3/4 to 1-1/2 in. diam, 1000 lb/sq. 3. Deck: C-15/32 Incline: 1 Vapor Retarder: —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation: —One or more layers UL Classified polyisocyanurate, perlite or glass fiber insulation, 1 in. to 1-1/2 in.total thickness. Base Sheet: —One layer Type G2 "Glasbase" base sheet. Membrane: —One layer "Flintlastic GTA(-3/4 sq or-1 sq), GTS, STA" (modified bitumen), heat fused or "Flintlastic GMS" hot mopped. Surfacing: —Gravel, 400 lbs/sq., (loose laid or in hot roofing asphalt). 4. Deck: NC Incline: 1 Base Sheet: —Type G2 "Glasbase". Ply Sheet: —Type G 1 or G2 glass fiber felt hot mopped. Membrane: —"Flintlastic GMS" hot mopped. Surfacing: —Gravel at 400 lbs/sq embedded in hot roofing asphalt. 5. Deck: NC Incline: 2 0000 . . 0000 0000.. Membrane: — "Flintlastic STA", "Flintlastic STA Plus", "GTA Black Diamond"',�'GTQ Whit,"•.• Diamond" or "GTA" with seams torched, laid loosely. 666:06 •• Surfacing: —River bottom stone (3/4 to 1-1/2 in. diam), 1000 lbs/sq. • 0000 .. 0000.. 0000 . .. 0000. 6. Deck: C-15/32 Incline: 1/4 •• 00;00• Insulation: —Glass fiber, perlite or wood fiber board, 6 in. offset joints, 3/4 to 2:1l�irk max. ' . . . . Ply Sheet: —Type 15 asphalt saturated organic felt. ••0000 00.000 Membrane: —"Flintlastic STA", "Flintlastic STA Plus", "GTA Black Diamond%'.1511 Whiff ••� ;0.06; Diamond" or "GTA" heat fused. • Surfacing: —Roofing gravel, 400 lbs/sq. 7. Deck:NC Incline: 1/4 Base Sheet(Optional): —Type 15 organic felt, mechanically fastened. Insulation (Optional): —Glass fiber, perlite or wood fiber, 2-1/2 in. max. Ply Sheet: —Type G2, adhered with hot roofing asphalt. Membrane: —"Flintlastic STA", "Flintlastic STA Plus", GTA Black Diamond", " GTA White Diamond" or " GTA", heat fused. Surfacing: —River bottom stone (3/4 to 1-1/2 in. diameter) 1000 lbs/sq. 8. Deck: C-15/32 Incline: 1/4 Insulation: —One or more layers of one of the following insulations, mechanically fastened, 1.0 in. file:///D:/Documents/TGFU.R116560/00 0 20-/o20Roofing/o20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 17 of 37 min, no max: Fiberboard, perlite, poly isocyanurate. Base Sheet: —G2 or G 1, hot mopped to the insulation. Membrane: —"Flintlastic GMS", "GMS Premium" (modified bitumen), hot mopped to the base sheet. Surfacing: —Gravel at 400 lbs/sq in hot roofing asphalt at 60 lbs/sq. 9. Deck: NC Incline: 1 Insulation: —One or more layers of one of the following insulations, mechanically fastened, 1.0 in. min, no max: Fiberboard, perlite, poly i socyanurate. Base Sheet: —Type G1 or G2, hot mopped to the insulation. Membrane: —"Flintlastic GMS", "GMS Premium" (modified bitumen), hot mopped to the base sheet. Surfacing: —Gravel at 400 lbs/sq in hot roofing asphalt at 60 lbs/sq. 10.Deck: NC Incline: 1 Insulation: —Polyisocyanurate, glass fiber, perlite,wood fiber, mechanically fastened or adhered with hot roofing asphalt, any thickness. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: —Gravel. 11. Deck: C-15/32 Incline: 1 Insulation: —Glass fiber, perlite, 3/4 in. min,joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. 0••• Surfacing: —Gravel. . .... ...... ...... .. . ...... 12. Deck: NC Incline: 1/2to ...:.. ...... Insulation: —Polyisocyanurate, glass fiber, perlite, wood fiber, mechanically fastened or adhered with ":'•. hot roofing asphalt, any thickness. : 0000 Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing aspll�.00 „. Membrane: —"Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black I3ian'io$d" or."GTA ....:. White Diamond", hot fused inp lace. .. . • •.• 13. Deck: NC Incline: 1/4 Insulation: —Polyisocyanurate, glass fiber, perlite, wood fiber, 3 in. max, mechanically fastened. Base Sheet: — "Poly SMS Base Sheet", mechanically fastened or adhered with hot roofing asphalt. Ply Sheet: —"Poly SMS Base Sheet", adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", adhered with hot roofing asphalt. Surfacing: —Gravel. 14. Deck: C-15/32 Incline: 3/4 Insulation (Optional): —Any thickness, one or more layers UL Classified perlite, glass fiber, polyisocyanurate. Barrier Board: —Min. '/4-in. thick G-P Gypsum Corp. "DensDeck® Roofboard"with all joints staggered a min of 6 in. from the plywood joints. Base Sheet(Optional): —One or more layers "Flex-I-Glas", mechanically fastened. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 18 of 37 Ply Sheet: —One or more layers "Flintlastic Ultra Poly SMS" or "Flintlastic Base 20 T", heat fused, or "Flintlastic Ultra Glass SA", self-adhered. Surfacing: —Gravel at 400 lbs/sq embedded in "F1intCoat-E" or APOC "APOC 302 Fibrated Emulsion" at 3 gal/sq. 15. Deck: NC Incline: 3/4 Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness. Ply Sheet: —"Flintlastic Ultra Glass SA". Surfacing: —Gravel at 400 lbs/sq embedded in "F1intCoat-E" or APOC "APOC 302 Fibrated Emulsion" at 3 gal/sq. 16. Deck: C-15/32 Incline: 2 Base Ply: —One layer of"Nail Base" or "Flexiglas Base," or "Flintlastic Base 20" or "Yosemite Venting Base", mechanically fastened. Ply Sheet: —"Flintlastic Ultra Glass SA". Surfacing: —Gravel at 400 lbs/sq embedded in "FlintCoat-E" or APOC "APOC 302 Fibrated Emulsion" at 3 gal/sq. Class B-Ballasted 1. Deck: NC Incline: 2 Insulation: —Glass fiber, perlite, wood fiber, 2-1/2 in. max, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. •••• Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing atphalt. •••• •••••• Surfacing: —Gravel. •••• • ...... .. . ...... 2. Deck: C-15/32 Incline: 1/2 ;••••• .... . .. ..... Insulation: —Glass fiber, perlite, wood fiber, 3/4 to 2-1/2 in.,joints in insulatio erriust be otfscl%in. from joints in deck, mechanically fastened. ••••• • Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalf. : .•••; Membrane: —"Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diarr*ond" ot"'UTA . . . White Diamond", heat fused. •• • . ... 000066 Surfacing: —Gravel. •• • 3. Deck: C-15/32 Incline: 1/4 Base Sheet: —Type G2, mechanically fastened. Membrane: —"Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused. Surfacing: —Gravel. 4. Deck: C-15/32* Incline: 1 *All joints blocked with 2xTs. Base Sheet: —Type G2, nailed. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 19 of 37 Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: —Gravel. 5. Deck: C-15/32 Incline: 1/4 Insulation: —Celotex "Hy-Tec", 2 in. min,joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: —Gravel. 6. Deck: C-15/32 Incline: 1/4 Insulation: —Celotex "Hy-Tec", 2 in. min,joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diamond" or "GTA APP White Diamond", heat fused. Surfacing: —Gravel. Class A-Fully Adhered In lieu of any membrane or membrane/surfacing shown below, "Flintlastic Ultra Poly SMS", covered with gravel, may be ulilized. 1. Deck: NC Incline: 1 0000 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified o retard`•"• YAP t ��•.. .' Insulation (Optional): —One or more layers or combination of the following: LJVOLWd Prft� er„ •�•�;� polyisocyanurate, perlite, glass fiber or wood fiber insulation. 000:00 0 Base Sheet: —One layer Type G2 "Glasbase"base sheet. 000000 0. Membrane: —One layer "Flintlastic GTA(-3/4 sq or-1 sq), GTS" (modified bituMOA), heat fusM r •�••• "Flintlastic GMS", hot mopped. 00:66: : 0''0 ••••• Surfacing: —APOC "No. 212 Fibrated Aluminum", at 1-1/2 gal. 100 sq/ft. 60 `6 "" 0000..2. 0 Deck: NC Incline: 3/4 0 0 . . 0000.. Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. • Insulation (Optional): —One or more layers or combination of the following: Ultragard Premier, polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —One layer of Type G2 "Glasbase" base sheet. Membrane: —One layer of"Flintlastic STA (modified bitumen), heat fused. Surfacing: —Karnak "No. 97 Fibrated Aluminum", at 1-1/2 gal. per 100 sq/ft. 3. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Schuller International "UltraGard Premier", polyisocyanurate, wood fiberboard, perlite, fiberglass, isocyanurate, any thickness. Base Sheet: —One or more plies of"Glasbase", hot mopped or mechanically fastened. Membrane: —One ply of"Flintlastic FR" (modified bitumen), hot mopped in place. 4. Deck: NC Incline: 1/2 file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 20 of 37 Insulation: —Polyisocyanurate, glass fiber, perlite, wood fiber, hot mopped or mechanically fastened, any thickness. Base Sheet: —Type G2, mechanically fastened or hot mopped. Membrane: —"Flintlastic GTA or STA", heat fused. Surfacing: —Henry Co. "Henry 520 Aluminum", applied at 1-1/2 gal/sq. 5. Deck: NC Incline: 1/4 Insulation (Optional): —Glass fiber, perlite or wood fiber board. Ply Sheet: —Type G2, mechanically fastened. Membrane: — "Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused. Surfacing: —Karnak Chemical Corp. "Karnak No. 97", 1 gal/sq. 6. Deck: NC Incline: 1 Insulation: —Polyisocyanurate, glass fiber, perlite, wood fiber, mechanically fastened or adhered with hot roofing asphalt, any thickness. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: —Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", 2- 1/2 gal/sq. 7. Deck: C-15/32* Incline: 1 *All joints blocked with 2x4's. Insulation: —Glass fiber, perlite, 3/4 in. min,joints in insulation must be offset 6 in. from jgip"in deck, mechanically fastened. •.•••• Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt •••• .' Membrane: —"Flintlastic GMS", adhered with hot roofing asphalt. •'•;•• •• •••••• Surfacing: —Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Asp%a] of Coatih ", 2- 1/2 gal/sq. ." Ro :•. • .... . .. ..... 8. Deck: NC Incline: 1/2 •• •• ••.. ...... Insulation: —Polyisocyanurate, glass fiber, perlite, wood fiber, mechanically fastened or aiff";d with,**• hot roofing asphalt, any thickness. •••••• Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. ' Membrane: —"Flintlastic STA", "Flintlastic STA Plus", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused in place. Surfacing: —Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", 3 gal/sq. 9. Deck: NC Incline: 1 Insulation (Optional): —Perlite, glass fiber, polyurethane, isocyanurate, phenolic combination isocyanurate/perlite, polyurethane/perlite or wood fiber, any thickness, hot mopped or nailed. Membrane: —"Flintlastic STA", "GTA", "GTA Black Diamond", "Flintlastic GTA White Diamond", "GMS", "GMS-5M", "GMS Double Coverage" or "GMS Premium", heat fused or hot mopped in place. Surfacing: —Grundy Industries, Inc. "al MB Aluminum Roof Coating" at 1-2 gal/sq. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 21 of 37 10. Deck: C-15/32 Incline: 1/4 Insulation (Optional): —Any thickness poly isocyanurate, glass fiber or perlite, mechanically fastened, joints in insulation must be offset 6 in. from joints in deck. Base Sheet: —Type G2 base/ply sheet, mechanically fastened or hot mopped. Ply Sheet: —Type G2 base/ply sheet, mechanically fastened or hot mopped. Membrane: — "Flintlastic STA", "Flintlastic STA Plus", "GTA White Diamond" or "GTA Black Diamond". Surfacing: —Grundy's "al MB Aluminum Roof Coating" at 1 to 2 gal/sq. 11. Deck: NC Incline: 1/2 Insulation (Optional): —Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically fastened. Base Sheet: —Type G2 "Flintlastic Base 20", mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 12. Deck: C-15/32* Incline: 1/2 *All joints in deck blocked with 2xTs. Insulation (Optional): —Polyisocyanurate, glass fiber, perlite, any combination, any thickness, mechanically fastened. Base Sheet: —Type G-2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 0000.. 00000:0 13. Deck: NC Incline: 1/2 0000..% 0000.... 0000.... Insulation (Optional): —EPS, any thickness, covered with 1/2 in. min perlite oreedfiber,:*. •• • mechanically fastened. 0000 • •• ••••• Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphJfT: .". ""'• �� �� �� �� �� •• �� �� 00 Membrane: — Flintlastic FR-P", Flintlastic Premium FR-P", Flintlastic FR-Dual ap or i�00 tlastic • FR Cap 30", adhered with hot roofing asphalt. ••�••• 0000.... . 0000.... 14. Deck: NC Incline: 1/2 •• ••• • 0000 Insulation: —Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically fastened. Base Sheet: —Type G2 or "Flex-I-glas", adhered with hot roofing asphalt. Ply Sheet: —"Poly SMS Base Sheet", adhered with hot roofing asphalt. Membrane: —"GMS", adhered with hot roofing asphalt. Surfacing: —Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", at 2- 1/2 gal/sq. 15. Deck: NC Incline: 1/4 Insulation (Optional): —Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness, mechanically fastened or adhered with hot roofing asphalt. Base Sheet: —Type G2 or "Flex-l-glas", mechanically fastened or adhered with hot roofing asphalt. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.RI 1656 - Roofing Systems Page 22 of 37 . Ply Sheet(Optional): —Type G2 or "Flex-I-glas", mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: —Asphalt Products Oil Corp. "APOC-400 Sunbrite", 3 gal/sq. 16. Deck: C-15/32 Incline: 1/4 Insulation: —Glass fiber, perlite, 1 in. min,joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet: —Type G2 or "Flex-I-glas", mechanically fastened or adhered with hot roofing asphalt. Ply Sheet(Optional): —Type G2 or "Flex-l-glas", mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic GMS", "GMS Premium", adhered with hot roofing asphalt. Surfacing: —Asphalt Products Oil Corp. "APOC-400 Sunbrite", 3 gal/sq. 17. Deck: NC Incline: 1/2 Insulation (Optional): —Polyisocyanurate perlite, glass fiber or wood fiber, any thickness, mechanically fastened or hot mopped in place. Base Sheet: —One or more layers of Type G2 or "Flex-I-glas", mechanically fastened or hot mopped in place. Ply Sheet(Optional): —One or more layers or Types G1, G2 or "Flex-I-glas", mechanically fastened or hot mopped in place. Membrane: — "Flintlastic GTA", "GTA Black Diamond", "GTA White Diamond" or "STA", heat fused. Surfacing: —Karnak Chemical Co. "No. 97", applied at 1-1/2 gal/sq. 18. Deck: NC Incline: 1/4 0000 ' 0 0000 000000 Insulation (Optional): —Perlite, glass fiber, mechanically fastened or hot moppedin.place,tin max ,• thickness. 000040 '.,• • 0000.. Base Sheet: —One or more layers of Type G2 "Flex-I-glas", mechanically fastMA tt hot mopped in :,..0.: 0 0000 00 . pace. • Ply Sheet(Optional): —One or more layers of Types G1, G2, "Flex-I-glas" or "M SMS$a o oSheet''':0 0. mechanically fastened or hot mopped in place. 0 . . Membrane: —"GTA", "GTA Black Diamond", "GTA White Diamond" or"ST.A:,heat fused,• •••• • Surfacing: —APOC No. 212 Aluminum Coating, applied at 1-1/2 gal/sq. 0 0 �,•„• 0 , . . 0000.. 19. Deck: C-15/32 Incline: 1/2 0 0 0 ”' • 0 . Insulation: —Glass fiber or perlite, min 1 in. thick, mechanically fastened or hot mopped in place. Base Sheet: —Type G2, "Flex-I-Glas" or "Flintlastic Base 20", mechanically fastened or hot mopped in place. Membrane: — "Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", hot mopped in place. 20. Deck: NC Incline: 2 Insulation (Optional): —Perlite, glass fiber, polyurethane, isocyanurate, phenolic, combination isocyanurate/perlite, polyurethane/perlite or wood fiber, any thickness, mechanically fastened or hot mopped in place. Base Sheet: —"Flintlastic Base 20", Type G2 or"Flex-I-Glas", mechanically fastened or hot mopped in file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.RI 1656 - Roofing Systems Page 23 of 37 place. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", hot mopped in place. 21. Deck: C-15/32 Incline: 1/2 Insulation: —Glass fiber or perlite, min 1 in. thick, mechanically fastened or hot mopped. Base Sheet: — "Flintlastic Base 20", mechanically fastened or hot mopped. Membrane:—"Flintlastic FR Cap 30", adhered with hot roofing asphalt. 22. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Polyisocyanurate, glass fiber, perlite, any combination, any thickness, mechanically fastened (joints in insulation must be offset 6 in. from joints in deck). Base Sheet(Optional): — "Poly SMS Base Sheet", fully adhered with hot roofing asphalt. Base Sheet: — "Flintlastic Base 20", mechanically fastened or fully adhered with hot roofing asphalt. Ply Sheet(Optional): —One or more plies of Type G1, G2, "Flex-I-Glas Base" or "Flintlastic Base 20", fully adhered with hot roofing asphalt. Membrane: —"Flintlastic FR Cap 30", fully adhered with hot roofing asphalt. 23. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Glass fiber or perlite, hot mopped or mechanically fastened, any thickness. Base Sheet: —One or more layers of"Flex-I-Glas" or "Flintlastic Base 20", adhered with Henry Co. "No. 200" or "HE#902 Permanent Bond Adhesive" at 1-1/2 gal/sq. Ply Sheet(Optional): —One or more layers of G 1, G2, "Flex-l-Glas", "Flintlastic Base 20" or "Poly SMS Base Sheet", mechanically attached or adhered with Henry Co. "No. 200" or "HE#902 Permanent Bond Adhesive", at 1-1/2 gal/sq or adhered with hot asphalt. Membrane: —"Flintlastic FR Cap 30" , adhered with Henry Co. "No. 200" or "HE#902 Permanent Bond Adhesive", at 1-1/2 gal/sq or hot mopped. 24. Deck: NC Incline: 1/2 •••• . . 0000 0000.. Insulation (Optional): —Polyisocyanurate, glass fiber or perlite, hot mopped ocnivahanicgUy fastened,...:. any thickness. 000:00 . 0000.. Base Sheet: —One or more layers of"Flex-I-Glas" or "Poly SMS Base Sheet",,'4?hAVastic J3ase20" or' • Type G2, mechanically fastened or adhered with Henry Co. "No. 200" or "HE#9U2'Permantnt Bond ":". Adhesive", at 1-1/2 gal/sq. ":": : 0000 0000' Membrane: —"Flintlastic FR Cap 30" , adhered with Henry Co. "No. 200"or;LIA #�02 Perm 00900* Bond Adhesive", at 1-1/2 gal/sq. • . . . . 0000.. 0000.. 25. Deck: NC Incline: 1/2 •• ••• • Insulation (Optional): —Glass fiber, perlite or poly i socyanurate, hot moped or mechanically fastened, any thickness. Base Sheet: —One or more layers of"Flex-I-Glas" or Type G2,hot mopped or mechanically fastened. Ply Sheet(Optional): —One or more layers of GI, G2, "Flex-I-Glas", "Flintlastic Base 20" or "Poly SMS Base Sheet", mechanically attached or hot mopped. Membrane: — "GTA Black Diamond", "GTA White Diamond", heat fused. Surfacing: —Henry Co. "Henry 520 Aluminum", at 1-1/2 gal/sq. 26. Deck: NC Incline: I file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 24 of 37 Insulation (Optional): —Any thickness, one or more layers UL Classified perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite, EPS/wood fiber, EPS/perlite, EPS/composite or Partek Insulation Inc. "PAROL" roof insulation. Base Sheet: —One or more layers Type G 1 or G2. Membrane: —One or more layers "Flintlastic GTA" or "-STA" (modified bitumen), heat fused. Surfacing: —Fields Corp. "F530 Heat Shield Aluminum Coating" or 7630 Heat Shield Fibered Aluminum Coating", 1-1/2 gal/sq. 27. Deleted. 28. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Glass fiber or perlite, hot mopped or mechanically fastened, any thickness. Base Sheet: —One or more layers GS Roofing Products "Flex-I-glas" or "Flintlastic Base 20", fully adhered or spot mopped with Henry "MBA Gold Adhesive" at 1-1/2 gal/sq or mechanically fastened. Ply Sheet(Optional): —One or more layers Types G1, G2, GS Roofing Products "Flex-I-glas", "Flintlastic Base 20" or "GS Polybase", adhered with Henry "MBA Gold Adhesive". Membrane: —GS Roofing Products "Flintlastic FR Cap 30", adhered with Henry "MBA Gold Adhesive" at 1-1/2 gal/sq or hot mopped. 29. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Isocyanurate, 2 in. min, glass fiber 1 in. min. Base Sheet: —Two or more layers Type G2 "Glasbase", first layer mechanically fastened. Membrane: —One layer "GTA/FR", torch applied. 30. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Isocyanurate, 2 in. min, glass fiber 1 in. min. Joint Treatment: —Two in. wide aluminum foil tape adhered to the plywood joints. Base Sheet: —One or more layers Type G2 "Glasbase", mechanically fastened. Membrane: —One layer "GTA/FR", torch applied. . . .... ...... 31. Deck: NC Incline: 1/2 • ...... .. . ...... Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, mechanically fastened or ..•.. hot mopped in place. Base Sheet: —One or more layers Type G2 base sheet, mechanically fastened 9; OO 16 ""place.,,;..• Ply Sheet(Optional): —One or more layers Type G1, mechanically fastened or.Fiatinopped*Ix place. ...... Membrane: —One layer "GTA/FR",torch applied. •••.•• . . . . ....% 32. Deck: C-15/32 Incline: 1/2 1 eee •••• .. . . ... . . Insulation (Optional): —Glass fiber or perlite, hot mopped or mechanically fastened, any thickness. Base Sheet: —One or more layers GS Roofing Products "Flex-I-glas" or "Flintlastic Base 20", adhered with Henry "MBA Gold Adhesive" at 1-1/2 gal/sq. Ply Sheet(Optional): —One or more layers Type G1, G2, GS Roofing Products "Flex-I-glas", "Flintlastic Base 20" or "GS Polybase", adhered with Henry "MBA Gold Adhesive". Membrane: —"Flintlastic FR Cap 30", adhered with Henry "MBA Gold Adhesive" at 1-1/2 gal/sq or hot mopped. 33. Deck: C-15/32 Incline: 1/2 file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 25 of 37 Insulation (Optional): —Glass fiber, perlite 3/4 in., thick min, mechanically fastened. Base Sheet: —One or more plies Type G2, hot mopped or mechanically fastened. Ply Sheet: —One or more plies Type G1, hot mopped. Membrane: —"Modified Premium Cap Sheet 960", hot mopped. 34. Deck: NC Incline: 1/2 Insulation (Optional): —Glass fiber, perlite, isocyanurate, mechanically fastened. Ply Sheet(Optional): —One or more plies Type G1, hot mopped or mechanically fastened. Base Sheet: —One or more plies Type G2, hot mopped or mechanically fastened. Membrane: —"Modified Premium Cap Sheet 960", hot mopped. 35. Deleted. 36. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Glass fiber or perlite, hot mopped or mechanically fastened. Base Sheet: —One or more layers Type "Flexiglas Base" or "Flintlastic Base 20", adhered with Henry "MBA Gold Adhesive" or Pro-Grade#333M/B Adhesive at 1-1/2 gal/sq. Ply Sheet(Optional): —One or more layers Type G1, G2, "Flintlastic Base 20" or 'Poly SMS Base" , adhered with Henry "MBA Gold Adhesive" or Pro-Grade#333M/B Adhesive at 1-1/2 gal/sq. Membrane: — "Flintlastic FR Cap 30", adhered with Henry "MBA Gold Adhesive" or Pro-Grade #333M/B Adhesive at 1-1/2 gal/sq or hot mopped. 37.Deck: C 15/32 Incline: 1/2 Insulation (Optional): —Glass fiber or Perlite, 1 in. thick min, or polyisocyanurate, 2 in. thick min. Base Sheet: —One or more layers "Yosemite Venting Base Sheet", mechanically fastened or hot mopped in place. Membrane: —One or more layers "Flintlastic FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap of mopped in place. : .0. .... .....• Surfacing: —Davlin Coatings "Firecade 2000", 1 1/2 gal/sq. or Monsey Products"Prdmiunl UtM Life • Aluminum Roof Coating", 1 1/2 gal/sq. •• •••••• 38. Deck: NC Incline: 2 •• • • Insulation (Optional): —Perlite, glass fiber, polyurethane, isocyanurate, phenollc.combination• isocyanurate/perlite, polyurethane/perlite or wood fiber, any thickness, mechanicall j fastened or riot •• mopped in place. •••••• Base Sheet: —"Flintlastic Base 20", Type G2 or"Flex-I-Glas", mechanically fastened or holt ed i4'*'*:o place. Ply Sheet(Optional): —One or more plies Type G1, mechanically fastened or hot mopped in place. Membrane: —"Flintlastic-FR/PG", "Flintlastic-FR-P", "Flintlastic Premium FR-P", "Flintlastic FR- Dual Cap" or "Flintlastic FR Cap 30", hot mopped in place. 39. Deck: NC Incline: 1 Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened. Membrane: —"Flintlastic GTA or GTS", heat fused or "Flintlastic GMS" (modified bitumen), hot mopped. Surfacing: —"APOC 212 AF Aluminum Fibre Roof Coating", 1-1/2 gal/sq. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 26 of 37 40. Deck: C-15/32 Incline: 1/4 Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or mopped. Membrane: —CertainTeed "Flintlastic GTA or GTS", heat fused or "Flintlastic GMS" (modified bitumen),hot mopped. Surfacing: —"APOC 212 AF Aluminum Fibre Roof Coating", 1-1/2 gal/sq. 41. Deck: NC Incline: 1 Vapor Retarder(Optional): —Type G2 base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combinations of the following: Polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —One layer Type G2, "Glasbase" base sheet. Membrane: —One layer "Flintlastic GTA, GTS" (modified bitumen), heat fused or "Flintlastic GMS", hot mopped. Surfacing: — "APOC 212 AF Aluminum Fibre Roof Coating", 1-1/2 gal/sq. 4 Deck: C 15/32 Incline: 1/2 Impact: 4 Base Sheet: —One or more layers "GlasBase", mechanically fastened. Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened. Ply Sheet(Optional): — "Flintlastic SA PlyBase", self-adhered. Cap Sheet: —One layer "Flintlastic SA Cap FR" or "Flintlastic SA P-Cap FR", self-adhered. 43. Deck: NC Incline: 1/2 Impact: 4 Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened or one layer"Flintlastic SA PlyBase", self-adhered. •••• Cap Sheet: —One layer "Flintlastic SA Cap FR" or "Flintlastic SA P-Cap FR",$elf adhered 0•••• 009% 6 . 0000 • . • .00. 0.0 ..• 0 :0000: 44. Deck: C 15/32 Incline: 1/2 Impact: 4 .,•;•• 0000 00 0 000000 Insulation (Optional): —Any UL Classified, any thickness. •0.0 ••0 ••••• Underlayment Board: —One layer 1/4 in. thick min. G-P Gypsum "DensDeclX;M0 echanieaWl0 000.0 00•• 000 00 00 0 0 0 0 fastened. • Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened or obe 15ytr "Fliptlastic SA•••„• PlyBase", self-adhered to primed "DensDeck®" or DensDeck Prime, only. :••••• • Cap Sheet: —One layer "Flintlastic SA P-Cap FR", self-adhered. •••• 0 • 000 ;0•••; 0 . 45. Deck: NC Incline: 1 Insulation (Optional): —Any UL Classified polyisocyanurate, wood fiber, glass fiber, or perlite, any thickness, mechanically fastened. Base Sheet: —"Flintlastic Base 20 T", heat welded. Membrane: —"Flintlastic FR Cap 30 T", heat welded. 46. Deck: NC Incline: 1 Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 27 of 37 Membrane: —CertainTeed "Flintlastic GTA or GTS", heat fused or"Flintlastic GMS" (modified bitumen), hot mopped. Surfacing: —"F1intCoat A300," (fibered aluminum) 1-1/2 gal/sq. 47. Deck: C-15/32 Incline: 1/4 Insulation (Optional): —Polyisocyanurate, glass fiber, wood fiber, perlite, any thickness. Base Sheet: —One ply Type G2, mechanically fastened or hot mopped. Membrane: —CertainTeed "Flintlastic GTA or GTS", heat fused or"Flintlastic GMS" (modified bitumen), hot mopped. Surfacing: —"F1intCoat A300," (fibered aluminum) 1-1/2 gal/sq. 48. Deck: NC Incline: 1 Vapor Retarder(Optional): —Type G2 base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: Polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —One layer CertainTeed Type G2 "Glasbase" base sheet. Membrane: —One layer CertainTeed "Flintlastic GTA, GTS" (modified bitumen), heat fused or "Flintlastic GMS", hot mopped. Surfacing: —"FlintCoat A300," (fibered aluminum) 1-1/2 gal/sq. 49. Deck: NC Incline: 3/4 Insulation (Optional): —Polyisocyanurate, glass fiber, or perlite, mechanically fastened, any thickness Base Sheet: —One or more plies Type G2, "Flexiglas Base," or "Flintlastic Base 20," mechanically fastened Ply Sheet(Optional): —One or more plies Type G2, "Flexiglas Base," or "Flintlastic Base 20," adhered with "FlintBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq Membrane: —"Flintlastic FR Cap 30", adhered with "FlintBond Brush Grade"pr APOC "#MI?at 1- 1/2 gal/sq •��• ...... .. . ...... 50. Deck: C-15/32 Incline: 1/2 "'••• • .... ...... Insulation: —Atlas "AC Foam III,"min. 1 in. thick .. �; • Base Sheet: —One or more plies Type G2, "Flexiglas Base," or "Flintlastic BaleNfpmecliarxeany fastened •••••• • Ply Sheet(Optional): —One or more plies Type G2, "Flexiglas Base," or "Flintlastic BaseM,"Whered••••• with "FlintBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq : •0• 0 �; Membrane: — "Flintlastic FR Cap 30", adhered with "FlintBond Brush Grade" or APOC "#3�6t';at I- 1/2 gal/sq 51. Deck: NC Incline: 1/2 Base Sheet: —One or more plies Type G2, "Flexiglas Base," or "Flintlastic Base 20," mechanically fastened. Ply Sheet(Optional): —One or more plies Type G2, "Flexiglas Base," or "Flintlastic Base 20," adhered with "FlintBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq Membrane: —"Flintlastic FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with "FlintBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq 52. Deck: C-15/32 Incline: 1/2 file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 28 of 37 Base Sheet: —Two or more plies Type G2, or one or more plies "Flexiglas Base," or "Flintlastic Base 20," mechanically fastened. Ply Sheet(Optional): —One or more plies Type G2, "Flexiglas Base," or"Flintlastic Base 20," adhered with "F1intBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq Membrane: —"Flintlastic FR-P" or "Flintlastic FR-Dual Cap" adhered with "F1intBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq 53.Deck: NC Incline: 1/2 Insulation (Optional): —Polyisocyanurate, any thickness, covered with 1/2 in. thick(min) gypsum board, 1/4 in. thick(min) G-P Gypsum DensDeck®or DensDeck Prime®. Base Sheet: —One or more plies Type G2, "Flexiglas Base," or "Flintlastic Base 20," mechanically fastened or adhered with "F1intBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq. Ply Sheet(Optional): —One or more plies Type G2, "Flexiglas Base," or"Flintlastic Base 20," adhered with "F1intBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq. Membrane: —"Flintlastic FR Cap 30", "Flintlastic FR-P" or "Flintlastic FR-Dual Cap", adhered with "FlintBond Brush Grade" or APOC "#136" at 1-1/2 gal/sq. 54. Deck: C 15/32 Incline: 1/2 Impact: 4 Insulation (Optional): —Any UL Classified, any thickness. Underlayment Board: —One layer 1/4 in.thick min. G-P Gypsum 'DensDeck®, mechanically fastened. Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened or one layer "Flintlastic SA PlyBase", self-adhered to primed "DensDeck®" or 'DensDeck DuraGuard® Roofboard", only. Ply Sheet: —One layer "Flintlastic SA PlyBase", self-adhered. Cap Sheet: —One layer "Flintlastic SA Cap FR", self-adhered. 55. Deck: NC Incline: 1/2 Impact: 4 Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened or one Layer"Flip;lse:ic SA PlyBase", self-adhered to deck surface. •.....•.•• •. Ply Sheet: —One layer"Flintlastic SA PlyBase", self-adhered. ""'• • Cap Sheet: —One layer "Flintlastic SA Cap FR", self-adhered. • .... . .. ..... 56. Deck: C-15/32 Incline• 1/2 ' Base Sheet: —Two or more layers Type G2 "Glass Base", mechanically fastened. •••:• Membrane: —One layer "Flintlastic GTS FR" (modified bitumen), heat fused.%.' •••••• 57. Deck: C-15/32 Incline: 3/4 Insulation (Optional): —Any thickness, one or more layers UL Classified perlite, glass fiber, polyisocyanurate. Barrier Board: —Min. '`/4-in.thick G-P Gypsum Corp. 'DensDeck® Roofboard" with all joints staggered a min of 6 in. from the plywood joints. Base Sheet(Optional): —One or more layers "Flex-I-Glas", mechanically fastened. Ply Sheet: —One or more layers "Flintlastic Ultra Poly SMS" or "Flintlastic Base 20 T", heat fused, or "Flintlastic Ultra Glass SA", self-adhered. Membrane: —One layer "Flintlastic GTS FR", heat fused. 58. Deck: NC Incline: 3/4 file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 29 of 37 Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness. Ply Sheet:—"Flintlastic Ultra Glass SA" Membrane: —"GTA- FR" heat fused 59. Deck: C-15/32 Incline: 2 Base Ply: —One layer of"Nail Base" or "Flexiglas Base," or "Flintlastic Base 20" or "Yosemite Venting Base" or Type 2 "GlasBase" -mechanically fastened. Ply Sheet: —"Flintlastic Ultra Glass SA" Membrane: —"GTA-FR" heat fused 60. Deck: C-15/32 Incline: 1/4 Base Ply: —Two layers of Type G2 GlasBase -mechanically fastened. Ply Sheet: —"Flintlastic Ultra Glass SA", self adhered Cap Sheet: — "SA Cap -FR", self adhered 61. Deck: NC Incline: 1/4 Ply Sheet: —"Flintlastic Ultra Glass SA" or"Flintlastic SA Mid-Ply", self adhered. Cap Sheet: — "SA Cap -FR", self adhered 62. Deck: NC Incline: 1/2 Insulation (Optional): —Glass fiber, polyisocyanurate, wood fiber, perlite, any thickness Ply Sheet: —"Flintlastic Ultra Glass SA" or "Flintlastic SA Mid-Ply", self adhered. Membrane: —"FR Cap 30", mopped or "FR Cap 30 T", heat fused 63. Deck: C-15/32 Incline: 1/2 •••• • 0000 0000.. .. 0000 Base Play: —One layer of GlasBase or Nail Base or Flexiglas Base, or Filixtlzstic Bgw.20, or ,,,,•, Yosemite Venting Base" -mechanically fastened. 9.9 9.0 , Ply Sheet: —"Flintlastic Ultra Glass SA", self adhered 000000 •• 9 :0000: Membrane: —"FR Cap 30", mopped or "FR Cap 30 T", heat fused 0000 • •• 00000 0000.. 64. Deck: NC Incline: 1/4 •• • 0000.. :000:9 • Base Sheet: —One layer Type G2 or "Flexiglas", mechanically fastened. 0 „ ,,•, Surfacing: — "Flintlastic Cap 30”, hot mopped. 0 ' 65. Deck: NC Incline: 3/4 Base Sheet: —"APP Base T", mechanically fastened or torched Ply Sheet(Optional): —"APP Base T", torched Cap Sheet: — "Flintlastic GTA-FR", torched 66. Deck: NC Incline: 2 Ply Sheet: —"Flintlastic Ultra Glass SA". Membrane: —"Flintlastic GTA- FR" heat fused. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 30 of 37 Class B-Fully Adhered 1. Deck: NC Incline: 1 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination of the following: UltraGard Premier, polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —One layer Type G2 "Glasbase" base sheet. Membrane: —One layer "Flintlastic STA" (modified bitumen), heat fused. Surfacing: —Karnak "No. 97 Fibrated Aluminum", at 1-1/2 gal/sq. 2. Deck: C-15/32 Incline: 1/4 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers UL Classified perlite or glass fiber. Base Sheet: —One layer Type G2 "Glasbase" base sheet. Membrane: —One layer "Flintlastic GTA, GTS" (modified bitumen), heat fused or "Flintlastic GMS", hot mopped. Surfacing: —APOC "No. 212 Fibrated Aluminum", at 1-1/2 gal/sq. 3. Deck: C-15/32 Incline: 1/4 Vapor Retarder(Optional): —Type G2 "Glasbase" base sheet or UL Classified vapor retarder. Insulation (Optional): —One or more layers or combination the following: Ultragard Premier, polyisocyanurate, perlite, glass fiber or wood fiber insulation. Base Sheet: —Two layers Type G2 "Glasbase" base sheet. Membrane: —One layer "Flintlastic STA" (modified bitumen), heat fused. Surfacing: —Karnak Chemical "No. 97 Fibrated Aluminum", at 1-1/2 gal/sq. 0000 4. Deck: NC • Incline: 2 Insulation: —Glass fiber, perlite, wood fiber, 2-1/2 in. max, mechanically fast41:adhered•with hots•••• roofinghalt. 0000.. asphalt. 6,6. .6 . , Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asplie4tt•• : •6.• Membrane: —"GMS", "GMS Premium", adhered with hot roofing asphalt. ••••• 0 6• .,:..• Surfacing: —Karnak Chemical "Karnak No. 97 Fibrated Aluminum Asphalt RMohfing", 24i� gal/ sq. 0.00:• j • . 5. Deck: C-15/32* Incline: 1/2 .0....• 00000 • 6 6 6. 6 . ..6 *All joints blocked with 2xTs. •• • Insulation: —Glass fiber, perlite, 3/4 to 2-1/2 in.,joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"STA", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused. Surfacing: —Karnak Chemical Corp., "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", 1- 1/2 gal/sq. 6. Deck: C-15/32* Incline: 1/4 *All joints blocked with 2x4's. file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 31 of 37 Base Sheet: —Type G2, mechanically fastened. Membrane: —"STA", "GTA", "GTA Black Diamond", "GTA White Diamond", heat fused. Surfacing: —Karnak Chemical Corp., "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", 1- 1/2 gal/sq. 7. Deck: C-15/32* Incline: 1/2 *All joints blocked with 2x4's. Base Sheet: —Type G2, nailed. Membrane: —"GMS", adhered with hot roofing asphalt. Surfacing: —Karnak Chemical Corp., "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", 2- 1/2 gal/sq. 8. Deck: C-15/32* Incline: 1/4 *All joints blocked with 2x4's. Insulation: —Celotex "Hy-Tec", 2 in. min,joints in insulation must be offset 6 in. from joints in deck, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"GMS", adhered with hot roofing asphalt. Surfacing: —Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating", 2- 1/2 gal/sq. 9. Deck: C-15/32* Incline: 1/4 *All joints blocked with 2xTs. 0000 Insulation: —Celotex "Hy-Tec", 2 in. min,joints in insulation must be offset 6in. floom joi$ts.ir►8eck, 0000.. mechanically fastened. 00 0 0000 • Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asptIMC•• •• • •••••• Membrane: —"STA", "GTA", "GTA Black Diamond" or "GTA White Diamond"Mat fused.• • 0000.. Surfacing: —Karnak Chemical Corp. "Karnak No. 97 Fibrated Aluminum Aspiipliloof Ceating•, 3 gal/sq. 00 00 0000 000000 10. Deck: NC 0.00•• • Incline: 1/2 • • • a •0000• • •0000• Insulation (Optional): —Polyisocyanurate, glass fiber, perlite, wood fiber, an�g0ridinatioN 411& thickness, mechanically fastened. 6..8 • Base Sheet: —Type G2 or "Flex-I-glas", mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap", "Flintlastic FR Cap 30" or "Flintlastic FR/PG", adhered with hot roofing asphalt. 11. Deck: C-15/32* Incline: 1/2 *All joints in deck blocked with 2xTs. Insulation (Optional): —Poly isocyanurate, glass fiber, perlite, any combination, any thickness, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 32 of 37 FR Cap 30", adhered with hot roofing asphalt. 12. Deck: NC Incline: 1/2 Insulation (Optional): —EPS, any thickness, covered with 1/2 in. min perlite or wood fiber, mechanically fastened. Base Sheet: —Type G2, mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. 13. Deck: C-15/32 Incline: 1/4 Insulation (Optional): —Perlite or glass fiber, any thickness or polyisocyanurate, any thickness, covered with a min of 1/2 in. perlite or glass fiber, mechanically fastened or hot mopped in place. Base Sheet: —One or more layers of Type G2 (min 24 lb/sq) or "Flex-I-Glas", mechanically fastened or hot mopped in place. Ply Sheet(Optional): —One or more layers of Types G 1, G2 or "Flex-I-glas", mechanically fastened or hot mopped in place. Membrane: —"GTA", "GTA Black Diamond", "GTA White Diamond" or "STA", heat fused. Surfacing: —Karnak Chemical Co.No. 97, applied at 1-1/2 gal/sq. 14. Deck: C-15/32 Incline: 1/4 Insulation (Optional): —Perlite, glass fiber or polyisocyanurate (any thickness) covered with min 1/2 in. perlite or glass fiber, mechanically fastened or hot mopped in place, 2 in. max thickness. Base Sheet: —One or more layers of Type G2 (min 24 lb/sq) or "Flex-I-Glas", mechanically fastened or hot mopped in place. Ply Sheet(Optional): —One or more layers of Types G1, G2, "Flex-I-Glas" or "Poly SMS Base Sheet", mechanically fastened or hot mopped in place. Membrane: —"GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused. •••• Surfacing: —APOC No. 212 Aluminum Coating, applied at 3 gal/sq. •••••• 15. Deck: C-15/32 •••••• • Incline: 1/2 Insulation (Optional): —Glass fiber, perlite or polyisocyanurate, hot mopped or"Uhanica'lly rastened,•;• • any thickness. Base Sheet: —One or more layers of"Flex-I-glas", hot mopped or mechanically Tastgged. 0000•,• • Ply Sheet(Optional): —One or more layers of Types G 1, G2, "Flex-I-Glas", "Flinttalic Base 20" or ••••:• "Poly SMS Base Sheet", mechanically attached or hot mopped. 0 0 :00000 • Membrane: —"GTA Black Diamond"or "GTA White Diamond", heat fused. '..o 0• ••• ' Surfacing: —Henry Co. " Henry 520 Aluminum", at 1-1/2 gal/sq. •' ' 16. Deck: C-15/32 Incline: 1/2 Barrier Board: — 1/2 in. min gypsum board, mechanically fastened(6 in. offset joints from the plywood joints). Insulation (Optional): —Polyisocyanurate, glass fiber, perlite, any combination, any thickness, mechanically fastened. Base Sheet: —Type G2 or"Flex-l-Glas", mechanically fastened or adhered with hot roofing asphalt. Membrane: —"Flintlastic FR-P", "Flintlastic Premium FR-P", "Flintlastic FR-Dual Cap" or "Flintlastic FR Cap 30", adhered with hot roofing asphalt. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 33 of 37 17. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Any thickness, one or more layers UL Classified perlite, glass fiber, poly i socyanurate, polyisocyanurate/composite or Partek Insulation "PAROC" roof insulation. Base Sheet: —One or more layers Type G2. Membrane: —One or more layers "Flintlastic GTA" or "-STA" (modified bitumen), heat fused. Surfacing: —Fields "F530 Heat Shield Aluminum Coating" or "F630 Heat Shield Fibered Aluminum Coating", 1-1/2 gal/sq. 18. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Isocyanurate, 2 in. min, glass fiber 1 in. min. Base Sheet: —One or more layers Type G2 "Glasbase", mechanically fastened. Membrane: —One layer "GTA/FR" (modified bitumen),torch applied. 19. Deck: C-15/32 Incline: 1/2 Base Sheet: —One or more layers Type G2, mechanically fastened. Membrane: —One or more layers "GTA" (modified bitimen), heat applied. 20. Deck: C-15/32 Incline: 1/2 Base Sheet:—One or more layers Type G2 "Glass Base", mechanically fastened. Membrane: —One layer "Flintlastic GMS", hot mopped or "Flintlastic GTS" (modified bitumen), heat fused. 21. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Any thickness, one or more layers UL Classified perlite, glass fiber?•• polyisocyanurate, 0 9 *00000 •••••• Barrier Board: —Min. '/4-in. thick G-P Gypsum Corp. "DensDeck®Roofboard!h4vith all j01hV. • staggered a min of 6 in. from the plywood joints. •••••• •' Base Sheet(Optional): —One or more layers "Flex-I-Glas", mechanically fast&Te*J.* •••••• Ply Sheet: —One or more layers "Flintlastic Ultra Poly SMS", heat fused. • Membrane: —One layer "Flintlastic GTS", heat fused. ..... . . 66066* .... ...... 22. Deck: NC Incline: '/2 ;••;•; Ply sheet: —"Flintlastic Ultra Glass SA" • Membrane: —"FR-P membrane", fully adhered "F1intBond Brush Grade" adhesive at 1-1/27074. 23. Deck: NC Incline: V2 Ply Sheet: —"Flintlastic Ultra Glass SA" Membrane: —"FR-P membrane hot mopped. 24. Deck: C-15/32 Incline: 1 Base Sheet: —One layer Type G2 or "Flexiglas", mechanically fastened. Surfacing: —"Flintlastic Cap 30", hot mopped. file:///D:/Document T o -o 0 s/ GFU.R11656/020 /o20Roofing/o20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 34 of 37 25. Deck: NC Incline: 1/4 Base Sheet: —"APP Base T", mechanically fastened or torched Ply Sheet(Optional): —"APP Base T",torched Cap Sheet: —"Flintlastic GTA", torched Class C-Fully Adhered 1. Deck: C-15/32 Incline: 1/2 Insulation (Optional): —Polyisocyanurate, perlite,wood fiber or glass fiber, mechanically fastened or hot mopped in place. Base Sheet: —One or more layers Type G2 or Flex-I-glas", mechanically fastened or hot mopped in place. Ply Sheet (Optional): —One or more layers Types G1, G2, "Flex-I-Glas" or "Poly SMS Base Sheet", hot mopped in place. Membrane:—"GMS", "GTA", "GTA Black Diamond" or "GTA White Diamond", heat fused. 2. Deck: C-15/32 Incline: Unlimited Impact: 4 Insulation (Optional): —Wood fiber, glass fiber or perlite, any thickness. Base Sheet: —One layer "Flintlastic SA NailBase ", mechanically fastened. Cap Sheet: —One layer "Flintlastic SA P-Cap FR", self-adhered. 3. Deck: C-15/32 Incline: 2 Impact: 4 Insulation (Optional): —Polyisocyanurate, wood fiber, glasss fiber or perlite, any thickness. Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened. Mid-Ply (Optional): —One layer "Flintlastic SA Mid-Ply" or "Flintlastic SA PlyBase", self q&red. Cap Sheet: —One layer "Flintlastic SA P-Cap FR", self-adhered. ••••.' ...... 4. Deck: C-15/32 Incline: Unlimited Impact: 4 •••••• •• • Insulation (Optional): —Wood fiber, glass fiber or perlite, any thickness. : '..' ••••• Base Sheet: —One layer "Flintlastic SA NailBase ", mechanically fastened. •• •'••• Cap Sheet: —One layer "Flintlastic SA Cap FR", self-adhered. .•' •••• •"' 5. Deck: C-15/32 Incline: 2 Impact: 4 ' Insulation (Optional): —Polyisocyanurate, wood fiber, glasss fiber or perlite, any thickness.•' Base Sheet: —One layer "Flintlastic SA NailBase", mechanically fastened. Mid-Ply (Optional): —One layer "Flintlastic SA Mid-Ply" or"Flintlastic SA PlyBase", self-adhered. Cap Sheet: —One layer "Flintlastic SA Cap FR", self-adhered. 6. Deck: NC Incline: 2 Impact: 4 Insulation (Optional): —Polyisocyanurate,wood fiber, glasss fiber or perlite, any thickness. Base Sheet: —One layer "Flintlastic SA Mid-Ply" or "Flintlastic SA PlyBase", self-adhered. Cap Sheet: —One layer "Flintlastic SA P-Cap FR", self-adhered. 7. Deck: NC Incline: 2 Impact: 4 file:///D:/Documents/TGFU.R11656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 35 of 37 Insulation (Optional): —Polyisocyanurate, wood fiber, glasss fiber or perlite, any thickness. Base Sheet: —One layer "Flintlastic SA Mid-Ply" or "Flintlastic SA PlyBase", self-adhered. Cap Sheet: —One layer "Flintlastic SA Cap FR", self-adhered. SINGLE PLY MEMBRANE SYSTEMS Class A- Ballasted 1. Deck: NC Incline: 2 Insulation: —"FlintBoardH ISO" "FlintBoardH ISO T" "FlintBoardH ISO F" "FlintBoardH ISO NB" "FlintBoardH ISO WF" or "FlintBoardH ISO T WF", any thickness. Membrane: —Any UL Classified, laid loosely. Surfacing: —River Bottom Stone (3/4 - 1-1/2 in. diam), 1000 lbs/sq. Class A-Fully Adhered 1. Deck: NC Incline: 1/2 Insulation: —"FlintBoardH ISO" or "FlintBoardH ISO T", any thickness, mechanically fastened. Membrane:—Carlisle "Sure-Seal FR", fully adhered with Carlisle "90-8-30A", 1-2/3 gal/sq or "FAST 100 Spray Polyurethane Foam Adhesive". 2. Deck: NC Incline: 1 Insulation: — "FlintBoardH ISO" or "FlintBoardH ISO T", any thickness. Membrane: —IB Roof Systems "IB Single Ply" adhered with TACC "LA 432", "LA432M" or Ashland "7008" adhesive at 1 gal/60 sq ft. Class B-Fully Adhered "" 1. Deck: NC Incline: 1/2000000 0 •• •••• • • Insulation: —"FlintBoardH ISO" or "FlintBoardH ISO T", any thickness, mechd'hlla*wy fasFreA• ••...• Membrane:—Carlisle "Sure-Seal FR", fully adhered with Carlisle "90-8-30A"j;*j�.gal/s4 or;.FAST..:..' 100 Spray Polyurethane Foam Adhesive". 0000 *0:0*0 000000 09 0 ...... . . • ...•.. Class A-Mechanically Fastened ••�• Certainteed insulation boards designated as "FlintBoardH ISO T", "FlintBoardH ISO F","'FlintBoar�VI1O • NB", " FlintBoardH ISO WF", FlintBoardH ISO T WF", "FlintBoardH ISO Cold" or " FlintBoardH ISO T Cold" are acceptable substitutes in any assembly which utilizes "FlintBoardH ISO". 1. Deck: NC Incline: 1/2 Insulation: — " FlintBoardH ISO", any thickness. Membrane: —GAF "Everguard" 2. Deck: NC Incline: 1-1/2 Insulation: —" FlintBoardH ISO", any thickness. file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 36 of 37 r Membrane: —Stevens "Stevens Hypalon" , Seaman "Fibertite", GenFlex "GenFlex RM" or Durolast "Duro-Last". 3. Deck: NC Incline: 3/4 Insulation: —" FlintBoardH ISO ", any thickness. Membrane: —Carlisle "Sureweld GSD". 4. Deck: NC Incline: 1/2 Insulation: —" FlintBoardH ISO", any thickness. Membrane: —Stevens "Stevens Hypalon" , Carlisle "FR Reinforced EPDM", GenFlex "GenFlex TPO" or Firestone "FR Rubberguard". 5. Deck: NC Incline: 1/4 Insulation: —" FlintBoardH ISO", any thickness. Membrane: —Firestone "LS-FR" or Carlisle "Sureweld". 6. Deck: NC Incline: 1/2 Insulation: —" FlintBoardH ISO", any thickness. Membrane: —Carlisle "Sure-Seal FR". 7. Deck: NC Incline: 2 ••• •••••• ...... .. . ...... Insulation: — " FlintBoardH ISO", any thickness. ••• •• .... ...... Membrane: —SarnaFil "SarnaFil 5327". •• .... . .. ..... 8. Deck: NC Incline: 1 ..•, • .... ...... Insulation: —" FlintBoardH ISO", any thickness. ; �; ••••.. Membrane: —IB Roof Systems "IB Single Ply". • Last Upoltxtl'oi 2014- Questions? Print this page Terms of Use Page Top ©2014 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment database for additional information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information,Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner,without any file:///D:/Documents/TGFU.R11656%20-%20Roofing%20 Systems.html 6/29/2015 TGFU.R11656 - Roofing Systems Page 37 of 37 manipulation of the data(or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition,the reprinted material must include a copyright notice in the following format: "©2014 UL LLC". .• • •••• •••••• •• •• •••• •••••• file:///D:/Documents/TGFU.Rl 1656%20-%20Roofing%20Systems.html 6/29/2015