RF-15-1284 1
Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-237615 Permit Number: RF-5-15-1284
Scheduled Inspection Date: July 20, 2015 Permit Type: Roof
Inspector: Rodriguez,Jorge Inspection Type: Final Roof
Owner: DAMSEAUX,VERONIQUE Work Classification: Flat
Job Address:50 NE 110 Street
Miami Shores, FL 33161-7044 Phone Number (305)975-8423
Parcel Number 1121360040360
Project: <NONE>
Contractor: ARCON ROOFING Phone: 954-753-3100
Building Department Comments
reroof 400 sq ft flat deck with 1.5" Infractio Passed CommentsINSPECTOR COMMENTS
False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-235596. ROOF OK
Missing uplift test
Failed 7- AE9 6;7
Correction ❑
Needed
Re-Inspection ❑
Fee
No Additional Inspections can be scheduled until
re-inspection fee is paid.
July 17, 2015 For Inspections please call: (305)762-4949 Page 16 of 35
5$ORF,S
Miami Shores Village
Eggs Building Department
10050 N.E.2nd Avenue
a '� Miami Shores, Florida 33138
�l0RID Tel: (305) 795.2204
Fax: (305) 756.8972
RE: Permit# ,Z 11-5-
DATE: �/
,Z
INSPECTION AFFIDAVIT
licensed as a(n) Contractor/Engineer/Architect,
(Print name and circle License Type) FS 468 Building Inspector
License#: ( �'C U S 76 7 -7
i
Z
XI did personally inspect the roof deck nailing and-
On or about W/'/,-,
(Date&time) /
work at s� 5`�arcGs
(Complete Job Site Address)
Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit
Manual(Based on 553.844 F.S)
x���
Signature
State of Florida
County of Dade:
The undersigned, being the first duly swom,deposes and says that he/she is the contractor for the above property
mentioned.
Sworn to and subscribed before me this 22- day of n e-
MARIA LE ICO
Notary Public, Sate of Florida at Large ;�2 ,' '' Notary Public-State of Florida
My Gomm.Expires Jan 11,2016
Commission#EE 139865
Bonded Through National Notary Assn.
'General,Building,Residential,or Roofing Contractors or any Individual certified under 488 F.S.to make such an inspection.Include photographs of each plane of the roof with
permit#and address#clearly shown marked on the deck for each inspection
Revised on 5/21/2009
t
p r
C- A T. L A B, N7 +C:.
Ti
July 15, 2015
Arcon Roofing
2280 NW 16 St
Pompano Beach, FL 33069
RE: TILE UPLIFT TEST
PROJECT INFORMATION PROVIDED BY CLIENT:
50 NE 110 St
Miami Shores, FL
Permit#: RF 5-15-1284
Property ID#: 11-2136-004-0360
Date inspected: July 14, 2015.
Date completed: June 23, 2015
Roofing Contractor: Arcon Roofing
Carlab, Inc Project # 15-8100
Testing lab Certificate #: 09-0127.04
Dear Sirs,
In accordance with your request and authorization, a representative of Carlab, Inc completed the Roof
Tile Uplift Test at the above referenced project. This testing was performed in general accordance with
Roofing Application Standard TAS No.106 Standard procedure for field verification of the bonding of
mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems.
The total of the tested roof surface area was estimated to be less than a total of 18' tie in area, and the
mean height of the roof is less than 30 feet above ground surface. The type of the used for this project
was reported to be Concrete / Clay Roof Tile. This tile was reported to have been foamed in place.
At the time of this testing, one test for every corner, one test for every 100 square feet of roof tile in
the perimeter area and one test for every 200 square feet of roof tile in the field area were tested.
Based on our test results, we conclude that the installation of the roof tile at the above referenced
project meets the test requirement outlined in the above mentioned protocol. Attached please find a
copy of our test report for your review.
Should you have any questions or if we may be of further assistance, please do not hesitate to contact the
undersigned.
l��sr�c6tfuP°�s't�brrl�t' ;-
NS '
� 3 ; l,% J-
�
enbio � 613:
`ORI
i
Eli:llfll-Y• ii
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 *FAX: 305.226.0438
TILE UPLIFT TEST
FOR
RESIDENCE
50 NE 110 ST
Miami Shores, FL
Project#: 15-8100
Test Test load Test Test Test load Test Test Test load Test
(lbo Status (lb fl Status (lbf) Status
1 35 Pass
2 35 Pass
3 35 Pass
4 35 Pass
5 35 Pass
6 35 Pass
7 35 Pass
8 35 Pass
9 35 Pass
10 35 Pass
8730 SW 25 STREET • MIAMI • FL • 33165 • PHONE: 305.283.3512 •FAX: 305.226.0438
s
N
N
Z
LJ
J
U
U
N
it
�- -� -1- +
I
FLAT ROOF 18' LONG TIE IN
LEGEND
+ FIELD TEST
— PERIMETER TEST
o CORNER TEST
i
C A R LA B
I NC.
FS61S11R .ASD PLV�SFRI
C FR4 'FLF-I(All Of .-\1111OR1/.-1IO\1;411)
K. \L"11,11 ttlbi 'CII: A\: 109 2_,0418
APPROX. R❑❑E TEST L❑CATI❑NS AND DIMENSI❑NS
0
�enO1S y, Miami Shores Village �sf
10050 N.E.2nd Avenue NE
Miami Shores,FL 33138 0000RO_
Phone: (305)795-2204 zj ' � �7-77
�C6RlDII' -
111110 iot
, ' , Expiration: 12/1612015
Project Address Parcel Number Applicant
50 NE 110 Street 1121360040360
VERONIQUE DAMSEAUX
Miami Shores, FL 33161-7044 Block: Lot:
Owner Information Address Phone Cell
LfVER.ONI.QUEE DAMSEAUX 50 NE 110 Street (305)975-8423
MIAMI SHORES FL 33138-
50 NE 110 Street
MIAMI SHORES FL 33138-
Contractor(s) Phone Cell Phone Valuation: $ 4,500.00
ARCON ROOFING 954-753-3100
Total Sq Feet: 400
Type of Work:Re Roof Available Inspections:
Additional Info:reroof 400 sq ft flat deck with 1.5 Inspection Type:
Classification:Residential
Tin Cap
Scanning:3 Final Roof
Roof in Progress
Renailing Affidavit
Review Roof
Review Roof
Review Roof
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
Bond Type-Contractors Bond $500.00
Invoice# RF-5-15-55746
CCF $3.00 06/19/2015 Check* 1154 $224.50 $550.00
DBPR Fee $3.75
DCA Fee $3.75 06/19/2015 Check#: 1153 $500.00 $50.00
Education Surcharge $1.00 05/28/2015 Check#: 1140 $50.00 $0.00
Permit Fee-New Roof $250.00 Bond#:2757
Scanning Fee $9.00
Technology Fee $4.00
Total: $774.50
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction'and zonin uthermore, authorize the above-named contractor to do the work stated.
� June 19, 2015
Authorized Signature:Owner / Applicant / Contractor / Agent Date
Building Department Copy
June 19,2015 1
I -
Miami Shores Village
•
lla e
6 Building Department-
114 M 2 8 2W5
`Qa 1 10050 N.E.2nd Avenue,Miami Shores,Florida 33138
!�Q Tel:(305)795-2204 Fax:(305)756-8972 I
INSPECTION LINE PHONE NUMBER:(30S)762-4949 LY=-
b'4 FB-C 201 0
BUILDING Master Permit No.F5 - 12-9 PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC EeROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
F-]PLUMBING ❑ MECHANICAL [-]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: lir6 // 6 JS
City: Miami Shores County Miami Dade Zip 32 ,14 /
Folio/Parcel#:_ 213 G u is V 6 3 G O Is the Building Historically Designated:Yes NO A.
Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name(Fee Simple Titleholder):_44 e, N J c l e �s Phone#: 3e 7.3
Address�j.,
City: /'�/�'1'Ji -r�a�-S State:
zip:---3J ,/ L/
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR:Company Name:
�OrG �jn s Phone#: � Jif f,;7y l!'Plot
-
Address: �- �/ Gxj /G a t' /
City: d /-fa -State: � Zip: 33c) & !9
Qualifier Name: /_ �,lLl ew-/„ Phone#: '
State Certification or Registration#: C e(_0,S_7 G �� Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Uv
Value of Work for this Permit:$ 4(S Square/Linear Footage of Work: �ly C'
Type of Work: ❑ Addition ❑ Alteration ❑ New 2Repair/Re lace ❑
D p Demolition
Description of Work: /G�9 Z14 6 S f 11=f /. -I-
Specify
Specify color of color thru tile: -' r
Submittal Fee$1,:;0 , "`' Permit Fee$ s x-�1 , M CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$I t '
TOTAL FEE NOW DUE$ moi'
(Revised02/24/2014) -q 211
r
Bonding Company's Name(if applicable)
Bonding Company's Address
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zohing.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signat a �/ Signature Q �^ Xe. ` J
OWNER or AGENT CONTRACTOR
The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this
- -2/ day of20 /-[ , by -L day of 20 by
KP24N e:6- b meo-C.-Aiho is personally known to who is personally known to
me or who has produced ��� as me or who has produced /Ply as
identification and who did take an oath. identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign:g Sign:
MARIA TALERICO
Print: "�°° '
a<'-. Print: .�rrrr�•r,
- a
* * MARIA�A�El;lle8
Notary Public-State of Florida
Seal: _'' + ' MY Comm. Expires Jan 11,2016 Seal: -
q
+ }°` Commission#EE 139865 '- ' + ' MY Comm.Expires Jan 11,2016
Bonded Through National Notary Assn. ' ; t°Pd Commission#EE 139865
rrrr rrr�
�P��
Bonded Through National Notary Assn.
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised02/24/2014i
5/26/2015 Property Search Application-Mimi-Dade County
OFFICE OF THE PROPERTY APPRAISER
Summary Report
Generated On:5/26/2015
Property Information
Folio: 11-2136-004-0360
Property Address: 50 NE 110 ST
Owner VERONIQUE DAMSEAUX
Mailing Address 50 NE 110 ST
MIAMI SHORES,FL 33161-7044
Primary Zone 1000 SGL FAMILY-2101-2300 SQ
Primary Land Use 0101 RESIDENTIAL-SINGLE
FAMILY: 1 UNIT
Beds/Baths/Half 2/2/0
Floors 1 ;
Living Units 1
Actual Area 2,204 Sq.Ft
Living Area 1,780 Sq.Ft
Adjusted Area 1,905 Sq.Ft
Lot Size 9,300 Sq.Ft
Year Built 1947 Taxable Value Information
2014 2013 2012
Assessment Information County
Year 2014 2013 2012 Exemption Value $50,000 $50,000 $50,000
Land Value $155,872 $88,004 $75,848 Taxable Value 1 $192,479 $188,896 $195,253
Building Value $129,159 $129,159 $145,137 School Board
XF Value $21,480 $21,733 $24,268 Exemption Value $25,000 $25,000 $25,000
Market Value 1 $306,511 $238,896 $245,253 Taxable Value $217,479 $213,896 $220,253
Assessed Value 1 $242,479 $238,896 $245,253 City
Exemption Value 1 $50,000 $50,000 $50,000
Benefits Information Taxable Value 1 $192,479 $188,896 $195,253
Benefit Type 2014 2013 2012 Regional
Save Our Homes Cap Assessment Reduction $64,032 Exemption Value 1 $50,000 $50,000 $50,000
Homestead Exemption $25,000 $25,000 $25,000 Taxable Value 1 $192,479 $188,8961 $195,253
Second Homestead Exemption $25,000 $25,000 $25,000
Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Sales Information
Board,City,Regional). Previous OR Book-
Sale Price PageQualification Description
Short Legal Description 07/01/2007 $482,500 25801-4410 2008 and prior year sales;Qual by exam
COLLEGE HEIGHTS PB 42-8 of deed
LOT 5 BLK 2 04/01/2005 $500,000 23327-4113 2008 and prior year sales;Qual by exam
LOT SIZE 75.000 X 124 of deed
OR 17587-1828 0397 1
COC 25801-4410 07 2007 1 03/01/1997 $119,500 17587-1828 2008 and prior year sales;Qual by exam
of deed
04/01/1993 $95,000 15887-0393 2008 and prior year sales;Qual by exam
of deed
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property
Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disciaimer.asp
Version:
Miami Shores Village
soil NUN" Building Department
$off 10050 N.E.2nd Avenue
�IOItIDp' Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date:
10050 NE 2nd Ave
Miami Shores, FI 33138,
Re: Owner's Name:
Property Address:
Roofing Permit Number:
Dear uilding Official:
I ,rr r
certify that I am not required to retrofit the roof to wall connections of my
b�uildiinn because: _
❑`The just valuation for the structure forur ose of ad valorem taxation p p on Is less than $300,000.00. Please attach proof of ad
valorem taxation.
❑The building was constructed in compliance with the provisions of the Florida Building Code(FBC)or with the provisions
of 1994 edition of the South Florida Building Code(1994 SFBC)
Z:;mat Print ame
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this .2 f day of
K! y
MARIA TALERICO
Notary Public-State of Florida
Notary Public, Sate of Florida at Lah4y Comm. Expires Jan 11,2016
= ,F o Commission#EE 139865
Ok When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than$300,000.00, 4§14.
• SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall Connection Hurricane Mitigation.
Revised on 5/21/2009
ROOF ' SB R FTOP STRUCTURES ��
MAY 2 2015
Florida Building Code Edition 2010
High-Velocity Hurricane Zone Uniform Permit Application Form.
Section A(General Information)
Cflpmimy Process No.
Contractor's Name /4 2e
Job Address .S-G ,� ,� //O .71
ROOF CATEGORY
xLow Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile
: . 0000 0000..
13 Asphaltic Shingles E3 Metal Panel/Shingles C3V4oe1.S'hinglea/Shakes .•
. .
0000.. .. . 000000
. .escriptive BUR-RAS 150 000000 t •
0000..
: •, 0000 00 0 0 0
ROOF TYPE .
• 0000 ..• 00000
000000 00 . .0000
0 New Roof Reroofing ❑ Recovering ❑ Repair •••••• ❑ Mailtenance••••••
000000 . 00
ROOF SYSTEM 0
. . . . 000000
INFORMATION :••0 0•
• .
000 000000
Low Slope Roof Area(SF) Steep Sloped Roof Area(SF) Total(So•••
Section B (Roof Plan)
Sketch Roof Pian:Illustrate all levels and sections,roof drains,scuppers,overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of
parapets.
:
I
C
i
: >
J I
10
i
f
15.34 2010 FLORIDA BUILDING CODE—BUILDING
rti
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
Mgh-Velocity Hurrlcane Zone Unlform Permit Application Form. nn
Section C(Low Slope Application) Surfacing: f�
Fill-in specific roof assembly components
and identify manufacturer Fastener Spacing for An Sheet Attachment:
(if a component Is not used,Identify as"NA")
Field: "oc ® Lap,#Rows Q 9 "oc
System Manufacturer.
t Perimeter: "oc @ Lap,#Rows 32 oc
Product Approval No.:
Corner: S "oc 0 Lap,#Rows y s "oc
Design Wind Pressures,From RAS 128 or Calculations:
-� Number of Fasteners Per insulation Board: i
P1.7 P2 /, 7 P3Iy
Max.Design Pressure,from the specific Product Field YI'4 Perimeter
Approval system: S.2_
Illustrate Components Noted and Details as
Deck: � �J Applicable:
Type: W0j Woodblocking,Gutter,Edge Termination,Stripping,
Flashing,Continuous Cleat,Cant Strip,Base Flashing,
Gauge/Thickness -S6" 6yxcl Counter-Flashing,Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of
Slope: _ Base Flashing,Component Material,Material Thickness,
�J� Fastener-type,Fastener Spacing or Submit Manufactur-
Anchor/Base Sheet&No.of Ply(s): ers Details that Comply with RAS 111 and Chapter 16
i, AncseShe t
F r riding Material: At the tie-in between the flat and the sloped roof -
Arcon will use 16", 26 gauge valley metal in a bed of
roof cement and nailed accordingly both in both
insulation Base Layer: /-r-O
Base Insulation Size and Thickness: z
FT, _
Base insulation Fasten-er/Bon in Maters
A 04?7' Parapet
Height
Top Insulation Layer:
Top Insulation Size and Thickness:- y�
Top Insulation Fastener/Bonding Material:
Mean
,C Roof
Bass Sheet(s)&No,of Ply(s): P1Y 6101 fVeV74 Height
Base Sheet Fastener/Boning Material
ovs� G�t�-
Ply Sheet(s)&No.of Ply(s):
Ply Sheet Fastener/Bonding Material: octse
Top ply (Q�fiA� COQ �IC��
0)
Top Ply Fastener/Bonding Material:
CHAPTER 15, SECTION 1524
HIGH VELOCITY HURRICANE ZONES
REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the
owner with the required roofing permit,and to explain to the owner the content of this section. The
provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and
standards of the industry for roofing system installations. Additionally,the following items should be
addressed as part of the agreement between the owner and the contractor. The owner's initials in the
designated space indicates that the item has been explained.
. Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High-Velocity Humc.=Q
Zone) are for the purpose of providing the roofing system meets the wind reysistapce and k4gt& 6066:6
intrusion performance standards. Aesthetics (appearance) are not a consid2,fpflop with respect 6
to workmanship provisions. Aesthetic issues such as color or architectural appr- ypvice,Mgt br& .606:0
not part of a zoning code should be addressed as part of the agreement bgW49g the owner
and the contractor. 6 6 6 6 6 0
6 . .. .
2. Renailing wood decks: When replacing roofing,the existing wood roof decK pZ66p6x have fp..be.b .6 6 6 0
renailed in accordance with current provisions of Chapter 16 (High-Velocity.HWricone Zones; 06:6.6
of the Florida Building Code, Building. (The roof deck is usually concealed prj •tcAemoSag the
exipr
sting roof system.) •
3.Common roofs: Common roofs are those which have no visible delineation I�etvJed-n neigh.bocing
units (ie., townhouses, condominiums,etc.). In buildings with common roofs,the roofing cvnlr'dctor
and/or owner should notify the occupants of adjacent units of roofing work td1d performed,0 0
Exposed ceilings: Exposed,open beam ceilings are where the underside of the roof decking.oan
. be viewed from below. The owner may wish to maintain the architectural appearance;therefore,
roofing nail penetrations of the underside of the decking may not be acceptable. The owner
provides the option of maintaining this appearance.
Z5. Ponding water. The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication
of structural distress and may require the review of a professional structural engineer. Ponding may
shorten the life expectancy and performance of the new roofing system. Ponding conditions may
not be evident until the original roofing,system is removed. Ponding conditions should be
corrected.
6. Overflow scuppers(wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a buildup of water. Perimeter/edge walls or other roof extensions may block this
discharge if overflow scuppers wall outlets) are not provided. It may be necessary to install
overflow scuppers in accordance with the requirements of:Chapters 16 and 16 herein and the
Florida Building Code, Plumbing.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall
not be reduced..
Exception: Attic spaces,designed by a Florida-licensed engineer or registered architect to eliminate
the attic venting,venting shall not be required.
RI 21 t-If
Z)& 4
O er's/A ignature ate Contractor's Signature
Form AB-326(Page 2 of 7) New 3/16/09
{ f
MI®DIADS MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
GAF
1361 Alps Road
Wayne,NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County FER•-6
Product Control Section to be used in Miami Dade County and other areas where allo4ed by the AuMdrtt�y
Having Jurisdiction(AHJ). •• •• •
606.96
This NOA shall not be valid after the expiration date stated below. The Miami-Dade C'ounly product :••••:
Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade.*�eunty);6•�0• 0 0 0 ••
reserve the right to have this product or material tested for quality assurance purposes.Jf 1jiOs•product pr. .6;6 6•
material fails to perform in the accepted manner,the manufacturer will incur the expense'of6s�'uch to%Ix 6'
and the AHJ may immediately revoke,modify,or suspend the use of such product or rnateviai within their •
jurisdiction. RER reserves the right to revoke this acceptance,if it is determined by Mtaml-Dade 4MI• ••••••
Product Control Section that this product or material fails to meet the requirements of*ie aIWicablt ;...6;
building code. •• ••• •
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Conventional Built-Up Roof Systems for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials,use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida,and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0424.09 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jorge L.Acebo.
.�J
NOA No.: 13-1022.15
MIAWDADE COUNTY Expiration Date: 11/04/18
' Approval Date: 11/06/1.4
Page 1 of 16
7
APPROVED ASSEMBLIES
Membrane Type: BUR
Deck Type 11: Wood, Insulated
Deck Description: 19/32"or greater plywood or wood plank
System Type A: Anchor sheet mechanically fastened,all layers of insulation adhered with approved asphalt.
All General and System Limitations shall apply.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShieldo Fire-Resistant Roof Deck Protection or
(optional) Securock®Gypsum Fiber Roof Board.
Anchor sheet: GAFGLAS®#80 UltimaTM Base Sheet, GAFGLAS® Stratavent®Eliminator?:N'itable
Venting Base Sheet,Ruberoid®20,Ruberoid®SBS Heat-Weld':Smooth or Ruberoid®Heat_%•
Weld'25 base sheet mechanically fastened as described below- •• ••• •
Fastening Options: GAFGLAS®Ply 4,GAFGLAS®Flex P1yTM 6,GAFGLAS#7519;9Sheet or an�of abo4&...:
anchor sheets attached to deck with approved annular ring shank na*);s•and tin osp�•ata •
fastener spacing of 9" o.c. at the lap staggered and in two rows 11';p',ci in the J-Lelo. ••
(Maximum Design Pressure—45 psf. See General Limitation #.7)• •
.. .. . ......
GAFGLAS®Ply 4, GAFGLAS®F1exP1yTM 6, GAFGLAS®#75 E e:gheet or any Qf abovg..„�
anchor sheets attached to deck with Drill-TecTM#12 Fastener, 130i11-Tge #1thaSt 1her and
Drill-TecTM 3" Steel Plate, Drill-TecTM AccuTrac®Flat Plate or Ini11-�e�TM Acw rac® :"'•:
Recessed Plate 12"o.c. in 3 rows. One row is in the 2"side lap. The other ros
aral�equally
spaced approximately 12"o.c. in the field of the sheet.
(Maximum Design Pressure—45 psf.See General Limitation #7)
GAFGLAS F1exPlyTM 6,GAFGLAS®#75 Base Sheet or any of above anchor sheets
attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of
9" o.c.at the 4"lap staggered and in two rows 9"o.c. in the field.
(Maximum Design Pressure—52.5 psf.See General Limitation #7)
GAFGLAS®#80 UltimaTM Base Sheet,Ruberoid®20, Ruberoid®Mop Smooth, base sheet
attached to deck with approved 1'/4"annular ring shank nails and inverted 3"steel plate at a
fastener spacing of 9" o.c. at the 4"lap and in two rows staggered with a fastener spacing of
9" o.c. in the center of the membrane.
(Maximum Design Pressure—60 psf. See General Limitation#7)
GAFGLAS®#75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecTM
#12 Fastener,Drill-TecTM#14 Fastener and Drill-TecTM 3" Steel Plate,Drill-TecTM AccuTrac®
Flat Plate or Drill-TecTM AccuTrac®Recessed Plate 12"o.c. in 4 rows. One row is in the 2"
side lap. The other rows are equally spaced approximately 9"o.c. in the field of the sheet.
(Maximum Design Pressure—60 psf.See General Limitation #7)
Any of above anchor sheets attached to deck approved annular ring shank nails and 3"
inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in
two rows 9" in the .field.
(Maximum Design Pressure—60 psf.See General Limitation #7)
NOA No.: 13-1022.15
M AMI-DARE COUNTY Expiration Date: 11/04/18
Approval Date: 11/06/14
Page 6 of 16
Fastening Options: GAFGLAS®#75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tee"
(Continued) #12 Fastener or Drill-TecT"'#14 Fastener and 3"Drill-TecT"3"Steel Plate,Drill-Tec T.
AccuTrac®Flat Plate or Drill-TecT"'AccuTrac®Recessed Plate 8"o.c. in 4 rows. One row is
in the 2"side lap. The other rows are equally spaced approximately 9"o.c. in the field of the
sheet.
(Maximum Design Pressure—75 psf.See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard—Polyiso Insulation,EnergyGuardTRA Polyiso Insulation,EnergyGuardT"'RA Composite
Polyiso Insulation
Minimum 1"thick •0•
N/A 0000 N/A 000000
. .
EnergyGuardTM Perlite Recover Board •• 000 •
066.0. .. 6 060..6
Minimum V2" thick N/A 098009 N/A ;0060;
rn, 0006 .. . 0 6
EnergyGuard Perlite Roof Insulation •
6666 6 66 66669
Minimum%11 thick N/A 000.0; 000609
Note: All insulation shall be adhered to the anchor sheet in full mopping of approve4vi asphalt within the 6 0 0
EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Sta ►dard:RAS 417 for 6660:0
0
insulation attachment. Composite insulation panels may be used as a top layer placeq with jhe polyisoc000..yanu*$r,0•;
side facing down. GAF requires either a ply of GAFGLAS®Stratavent®EliminatorT Perfotated XeiMiQg Bane
Sheet laid dry or a layer of EnergyGuardT"'Perlite Roof Insulation or wood fiber overlay board on all
isocyanurate applications.
Base Sheet: Optional)Install one ply of GAFGLAS®#75 Base Sheet, GAFGLAS®#80 UltimaT'Base
Sheet, GAFGLAS®Stratavent'Eliminator T.Perforated Venting Base Sheet,Ruberoid'Mop
Smooth,Ruberoid®20,Ruberoid®SBS Heat-Weld TM Smooth or Ruberoid®SBS Heat-Weld TM
25 directly over the top layer of insulation. Adhere with any approved mopping asphalt
applied within the EVT range and at a rate of 20-40 lbs./sq; (see General Limitation#4).
Ply Sheet: One or more plies GAFGLAS®PLY 4, GAFGLAS`'Flex PIyT'6 sheet or GAFGLAS®#80
Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq.
Cap Sheet: (Optional) One ply of GAFGLAS®Mineral Surfaced Cap Sheet or GAFGLAS®
EnergyCapT BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved
asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen
components must be applied according to manufacturer's application instructions. All
coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat
of approved asphalt at 601bs./sq.
2. Topcoat®Surface Seal SB applied at Ito 1.5 gal./sq.
Maximum Design
Pressure: See Fastening Options.
NOA No.: 13-1022.15
MIAMI•DADE COUNTY Expiration Date: 11/04/18
• ' Approval Date: 11/06/14
Page 7 of 16
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS®Ply 4 and GAFGLAS®Flex Ply6 when used as a mechanically fastened
base or anchor sheet.
2. Minimum 1/4"DensDeckT`"Roof Board or 1/2"Type X gypsum board is acceptable to be installed directly over the
wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied.W4hin the
EVT range and at a rate of 20-40 lbs./sq.,or mechanically attached using the fastening pattern of tlla wp Layer ••••••
3. All standard panel sizes are acceptable for mechanical attachment. When applied in appf8vad asphaltVanel size ••
shall be 4'x 4'maximum. •
4. An overlay and/or recovery board insulation panel is required on all applications overCldWcell foam•insulati"..;
when the base sheet is fully mopped. If no recovery board is used the base sheet shall bls a'pjpiied ungesFot •
00
mopping with approved asphalt, 12 diameter circles,24 o.c.; or strip mopped 8" ribbons In three rows one at •
each sidelap and one down the center of the sheet allowing a continuous area of ventil*Jio 0 eEncirC U� the ...•.
strips is not acceptable.A 6" break shall be placed every 12'in each ribbon to allow c4w.wtilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attAchedsystems shall be ••••:•
limited to a maximum design pressure of-45 psf.
S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force F' dalue a;....
'C ) Of'2Z3 jbf., as'
tested in compliance with Testing Application Standard TAS 105. If the fastener value,as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required,as determined by the Building Official,a revised fastener spacing,
prepared,signed and sealed by a Florida Registered Professional Engineer,Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117.Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect,or Registered Roof Consultant (When this limitation is specifically referred within
this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers,metal profile,and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e. perimeters,extended corners and corners). (When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 13-1022.15
MIAMI-DADE COUNTYM Expiration Date: 11/04/18
Approval Date: 11/06/14
Page 16 of 16
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
+ SECTION 1525
HIGH-VELOCITY HURRICANE ZONES UNIFORM PERMIT APPLICATION
0
Florida Building Code Edition 2010
High-Velocity Hurricane Zone Uniform Permit Application Form. o
INSTRUCTION PAGE.
COMPLETE THE NECESSARY SECTIONS OF .... o
THE UNIFORM ROOFING PERMIT •••• •
Y f •• • • ••• •�
APPLICATION FORM AND ATTACH THE 006.0• •••o 0 0000O?•
• '
REQUIRED DOCUMENTS AS NOTED BELOW: .. •. :••«%�
• . . • p°
o.
Roof System Required Sections of the Attachments Requitexi •• •• 6 ::0:44:00.
Permit Application Form See List Below*6 6 .• 6 6 6 6 6 6 6 6 6�L6 6
•
�ow_Slope Application A,B,C 1,2,3,4,5,6,7 ; ; 6 6 •6;;6 .
-------------------
0..000
Prescriptive BUR-RAS 150 A,B,C 4,5,6,7 • 0.0;0•
•• •
A,B,D
Asphaltic Shingles 1,2,4,5,6,7
• a
Concrete or Clay Tile A,B,D,E 1,2,3,4,5,6,7
1 '
Metal Roofs A,B,D 1,2,3,4,5,6,7
Wood Shingles and Shakes A,B,D• 1,2,4,5,6,7 Q
' b
Other As Applicable 1,2,3,4,5,6,7
s
• o
• e
ATTACHMENTS REQUIRED: °
1. Fire Directory Listing Page
2. From Product Approval: 9
Front Page
Specific System Description -,
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. 2eBsign Calculations per Chapter 16,or If Applicable, RAS 127 or RAS
I
i
4. Other Component of Product Approval
t
5. Municipal Permit Application I
i
6. Owners Notification for Roofing Considerations(Reroofing Only) 1
I 1
� I
7. Any Required Roof Testing/Calculation Documentation
• r
2010 FLORIDA 6UILDING CODE—BUILDING 15.33
Q11.
2007 ROOFING MATERIALS ANUWSTEMS DIRECTORY
192 ROOF COVERING MATERIALS(TEVT) ROOF COVERING MATERIALS(TEVT)
Roofing Systems (TGFU)—Continued Roofing Systems (TGFU)—Continued
Base Coat: "A-38 Series",0.75.gal/sq. "GAFTEMP Permalite Recover Board" maybe used.in lieu of any perlite
Second Base Coat: "A-38 Series",0.75 gal/sq. insulation in any of the following NC Classifications.
Wear Coat: "A-38 Series",0.75gal/sq plus walnut shells at 0.75 lbs per Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot
sq Roofing Asphalt"may be surfaced with"Fireshield MB"at 2.5—3.0 gal/sq.
Surfacing: "A-38 Series.",0.75 gal/sq plus walnut shells at 0.75 lbs per Class A,B and C
sq. Hot roofing asphalt,for use with organic and glass felts or modified bitumen
46 Deck:NC Incline:3/4 membranes.
s ne.ma be used in lieu of
Foam: Spray application of 2-in.thick"Pol foam 273" 2.7 lb/ft. ) "Ruberoid Heat Weld" SBS.roofing membra y
P Y PP Y ( _ g
Surfacing: Spray application of 28 to 347mils"1J78730"(aluminum) "Ruberoid Mop"SBS products in any applicable Classification.
!` 47 Deck:NC Incline:,1/2 Class A
Insulation: Spray application of 2-in.thick'Tolyfoam 273"(2.7 lb/ft.' 1. Deck:C-15/32 Incline:3
Insulation (Optional): One or more layers perlite, wood fiber, glass
Surfacing: Spray application of 28 to 34 mils"U-8782"(ivory) fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/
GAF MATERIALS CORP R1306 urethane composite,wood fiber/isocyanurate composite,phenolic,any
GAF MATERIALS CORP R 1300 6
thickness.
1361 ALPS RD,WAYNE NJ 07470 Ply Sheet: Three or more layers Type Gl "GAFGLAS Ply 4" or
"Ruberoid 20" or "Ruberoid Modified Base Sheet"mayy be utilized as an "GAFGLAS Ply 6",hot mopped.
j' alternate to Type G2 base sheets in any of the following classifications. Surfacing: Gravel.
x 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G-P Gypsum 2. Deck:C-15/32 - Incline:2
t DensDeck®may be used in any existing noncombustible deck Classification.
Insulation (Optional): One or more layers perlite, wood fiber, glass
When this is done, the resulting roofing system is acceptable for use over
combustible(15/32 in.min)roof decks.The joints in the gypsum board and fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/
overlayment board are offset 6 in.with the joints in the deck.If polystyrene is urethane composite,wood,fiber/isocyanurate composite,phenolic,any
part of the roof system,it must be placed below the overlayyment board. thickness.
' Also,multiple plies of"GAFGLAS Ply 4"or"Ply 6"may be adhered to G-P Ply Sheet: Three or more layers Type Gl "GAFGLAS Ply 4" or
d'�11 Gum DensDeck®in hot asphalt. "GAFGLAS Ply 6".
T"EnergyGuard Ultra"is an acceptable alternate to "EnergyGuard"in any Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap
applicable Classification. Sheet"or"EnergyCap Mineral Surfaced Cap Sheet".
'GAF Stratavent Eliminator Venting Base Sheet(Nailable)"may be mechani-
' tally attached or hot mopped over noncombustible decks and as a recover over 3. Deck:NC Incline:2
existing roof systems. Insulation (Optional): One or more layers,perlite, wood fiber, glass
GAFGLAS Perlite Insulation may be utilized as a cover board over"EVER- fiber,'isocyanurate, urethane, perlite/isocyanurate,composite, perlite/
+ GUARD"insulation in any of the following systems. Iurethane composite,wood fiber/isocyanurate rorrmposite,phenolic,2 in.
Unless otherwise indicated, the roof insulation is mechanically fastened, max.
adhered with hot mopping asphalt or urethane insulation adhesive.Polysty- Ply Sheet: Two or more layers Type Gl "GAFGLAS Ply 4"or"GAF-
a` rene reference in any of the following Classficatons include"ENERGuard EPS GLAS Ply 6".
Insulation". Cap_Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Cap
References to glass fiber insulation include "EnergyGuard Fiberglass Insu- Sheet"or"EnergyCap Mineral Surfaced Cap Sheet".
latiori. 4. Deck:NC Incline:1/2
,+ ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Insulation: One or two layers"J:kerm R",4 in.max,hot mopped;,
Type G2 aspphalt glass mat base sheet ("GAFGLAS #75 Base Sheet" or Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fiber
"GAFGLAS#80 ULTIMA")is a suitable alternate for Type Gl as halt glass
H; " mat system.
k�l fiber ply sheet("GAFGLAS Ply 4"or GAFGLAS Ply'6")in the C ass A,B or 5. Deck:C-15/32 Incline:1
C roof systems indicated below.
I The roof deck may first be covered with a Type G2 asphalt glass mat base Slip Sheet(Optional): Red rosin paper,nailed to deck.
sheet"GAF Stratavent Eliminator Venting Base Sheet(Perforated)"or"GAF Base Sheet: One layer Type G2"GAFGLAS#75 Base Sheet" (may be
Stratavent Eliminator Venting'Base Sheet (Nailable)". Perforated to be nailed).
i; mopped and nailable to be mechanically attached granule side down.: Ply Sheet: One or more layers Type Gl"GAFGLAS Ply 4"or GAFGLAS
As an,option Type G2 asphalt glass mat base sheet ("GAFGLAS#75 Base
Sheet","GAFGLAS#80 ULTIMA"or"GAF Stratavent Eliminator Venting Base Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced CaF
g' Sheet (Nailable)" may be substituted for.Gl asphalt glass fiber ply sheet Sheet"or"EnergyCap Mineral Surfaced Cap Sheet".
("GAFGLAS ply 4" or ':GAFGLAS Ply 6" ) as the nailed'base ply in the Deck:NC Incline:3
following systems. Base Sheet: One layer Type G2"GAFGLAS#75 Base Sheet".
Bottom ply or base sheet may be solid'mopped,spot mopped or mechari
Ply Sheet: One or more layers Type Gl "GAFGLAS Ply 4"or"GAF
{{ Cally fastened.
1{ Unless otherwise indicated,all insulations may be hot mopped or mechani- GLAS Ply 6".
!t1 tally fastened. Cap.Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced CaF
"GAFGLAS Flashing"or"Ruberoid"may be used for flashing in any of the Sheet"or"EnergyCap Mineral Surfaced Cap Sheet
Class A,B or C systems listed below. 7. Deck:C-15/32 Incline:2
When"perlite"is referenced,this includes"GAFTEMP P:ERMALITE®" or Insulation: One or more layers perlite, glass fiber, isocyanurate, ure
IY� any other UL Classified perlite insulation. thane,perlite/isocyanurate composite,perlite/urethane composite,phe
lq( Crushed stone or slag are suitable alternates for gravel in any of the Class A, nolle,1.0 in.min(offset from plywood joints 6 in.).
B or C systems listed. Base Sheet: One or more layers Type Gl,G2 or G3.
Membrane: One or
( . Structural cement fiber building units are considered suitable to be included MbOmore layers"Ruberoid Torch"(Smooth or Granule)
+ , as a deck in the following Class A,B or C systems listed over C-15/32 or NC. Y
The use of gypsum board under any of the following Class A,B or C systems "Ruberoid Torch Plus"(granule),"Ruberoid Mop"(Smooth or.Granule
Y does not adversely effect the rating'.The use of 1/2 in.min gypsum board is an or"Ruberoid Mop Plus"(granule).
j' acceptable alternate for insulation over C-15/32 decks. Cap Sheet: Type G3 "GAFGLAS Mineral Surfaced Cap Sheet" o
The use of polystyrene insulation board between min 3/4 in.perlite board "EnergyCap Mineral Surfaced Cap Sheet",hot mopped.
and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a 8. Deck:C-15/32 Incline:2
suitable alternate for isocyanurate board in the following Class A, B or C Insulation (Optional): One or more layers perlite, wood fiber, glas
%i systems. fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite
BMCA EnergyGuard RA","BMCA Tapered EnergyGuard RA"and"BMCA urethane composite,wood fiber/isocyanurate composite,phenolic,an
EnerpGuard RA may be substituted for any Atlas polyisocyanurate insula- thickness.
tion in any of the following Classifications. Base Sheet: Two or more layers Type G2 or G3.
Trumbull"Perms Mop"may be utilized with any of the following"Asphalt
Roofing Asphalt". Ply Sheet(Optional): One or more layers Type Gl.
Felt Systems with Hot
GAFGLAS#80 Premium Base She may be used in any of the following Membrane: One or more layers"Ruberoid Torch"(Smooth or Granule
systems. "Ruberoid Torch Plus"(granule),"Ruberoid Mop"(Smooth or Granuli
�'' "GAFGLAS Flex Ply 6"is a suitable alternate to"GAFGLAS Ply 6". or"Ruberoid Mop Plus"(granule).