Loading...
RC-14-1050 (2) � lt� Miami Shores Village �e Building Department MAY 21 2014 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 BY:.�_�2 . Tel:(305)795.2204 Fag:(305)756.8972 INSPECTION'S PHONE NUMBER:(305)762.4949 �D l� FBC 20 ILDING Permit No. PERMIT APPLICATION Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: 95 NW 95th Street City: Miami Shores County: Miami Dade Zip: 33150 Folio/Parcel#: 11-3101-033-0540 Is the Building Historically Designated:Yes NO X Flood Zone: X OWNER:Name(Fee Simple Titleholder):Bibiana I Patino Phone#:(786)252-1343 Address:95 NW 95th Street City: Miami Shores State: Florida Zip: 33150 Tenant/Lessee Name: Phone#: Email: perpatllc@gmail.com CONTRACTOR:Company Name: Pirsa Miami Corp Phone#: (786)252-5732 Address: 13715 SW 84th Street#B City: Miami State: Florida Zip: 33183 Qualifier Name: Alejandro Perez Phone#: (786)252-5732 State Certification or Registration#: CGC 1508748 Certificate of Competency#: Contact Phone#: 06 252-5-)32 Email Address:",c./SGtA'1 1 11 1 sw , DESIGNER:Architect/Engineer: Phone#: Value of Work for this Permit:$ - /, Square/Linear Footage of Work: 300 Sq.Ft Type of Work: AAddition ❑Alteration ❑New ORepair/Replace ❑Demolition Description of Work: New Terrace Color thru tile: Submittal Fee$ _Permit Fee$x-31 • CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ _ TOTAL FEE NOW DUE$ . 19 • Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature � O Signature er or Agent -1421- �ontractor The foreg i g instrumentt/was acknd d before me tfi �� The foregoing instrument was acknowledged before me this day of�,20 Lam,by /A day of r`a 20 ,by I�be-A"t rD &-,.w o� who is personally known to me or who has produced who is personally known to me or who has producedP6oqg As identificatiommidAv4W ar attl .0 F Fru D DO-1 gdo Sas identification and who did take an oath. Ri DA NOTARY PUB '` MERCEDES B. ESPERi9MARY PUBLIC: MY COMMISSION#EE 1716 EXPIRES June 16,2014 Sign: Sign: Print: P/�2 -Q�/71 Pri ORR 04 My Commission Expires: �G a My Commi ire# rs' ota Public State of Florida Joanna M Feliciano My Commission FF 082753 er Expires 0 111212018 *#a,kkk�kkN:kkkk#k:kkk*kkak#k*kkkk :kk:k# �*# ,kkKkA**A:*k+k%�k#% &k*sk*kskkkak�k�ksk*kRk*KikK*kkAkkk*kk khkkkk Rkkk #*k.K* APPROVED BY Plans Examiner Zoning Zt 1 Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) S�IORFs n •u• Miami shores Village Building Department �lOR1Dp 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LICENCES B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE* D. COPY OF WORKERS COMPENSATION INSURANCE* IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT B. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. C. COPY OF LIABILITY INSURACE* D. COPY OF WORKERS COMPENSATION INSURANCE* *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. BUSINESS NAME: / ,4�SA N//1t-Nt tr. BUSINESS ADDRESS: 1:57/S- 5Ck-) �'� CITY e STATE 77L- ZIP CODE 3--,;5(� 3 BUSINESS PHONE: 2 t�2 -5_�?3Z FAX NUMBER( ) CELL PHONE ( ) QUALIFIER'S NAME: ,SIG(a r,_42y Dares QUALIFIER'S LIC NUMBER: STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 PEREZ, ALEJANDRO PIRSA MIAMI CORP 1137715 SW 84TH STREET MIAMI FL 33183 Congratulations! With this license you become one of the nearly one million STATE OF FLORIDA AC# F 50 1 1DEPARTMENT OF BUSINESS AND Floridians licensed by the Department of Business and Professional Regulation. PROFESSIONAL REGULATION Our professionals and businesses range from architects to yacht brokers,from boxers to barbeque restaurants,and they keep Florida's economy strong. CGC1508748 06/02/12 118197111 Every day we work to improve the way we do business in order to serve you better.' For information about our services,please log onto www.myfloridalicense.com. CERTIFIED GENERAL CONTRACTOR There you can find more information about our divisions and the regulations that PEREZ;, ALEJANDRO impact you,subscribe to department newsletters and learn more about the PIRSA MIAMI CORP Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly.We constantly strive to serve you better so that you can serve your customers. IS CERTIFIED under the proviaiona of Ch.489 Fs Thank you for doing business in Florida, and congratulations on your new license! expiratim dace: AUG 31, 2014 L12060200296 DETACH HERE THIS DOCUMENT HAS A COLORED AC# 615 0 312 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD SEQ#L12060200296 . • - LICENSE NBR 06 02 2012 118197111 CGC1508748 The GENERAL CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2014 PEREZ, ALEJANDRO PIRSA MIAMI CORP 13715 SW 84TH STREET B MIAMI FL 33183 RICK SCOTT KEN LAWSON GOVERNOR SECRETARY ... ...................... . . . . DISPLAY,4S REQUIRED BY LAW SNORES e,,, ,,,,,l" Miami shores Village Building Department OR 10050 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner - Workers' Compensation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation,or in the case of an LLC,a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State,Division of Corporations;and 3. The corporation is registered and listed as active with the Florida Department of State,Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption. In these circumstances,Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company. Therefore,you may be personally liable for the worker compensation injuries of any person allowed to work under this permit. Please check with your insurance carrier since most property insurance policies DO NOT cover this type of liability. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. OwnerContractor Print Name: J T Print Name: Signature: 6I 8 J Ak A 1ATIt40 Signature: ezro, 1,Q[C,> c CUA- State of Florida) State of Florida) County of Miami-Dade) County of Miami-Dade) y� Sworn to an s sc ' ed before me this Sworn to ansybscrjhed before me this day of 20/47 day of 20 l l . By By­ NOTARY NOTARY PUBLIC STATE OF FLORIDA N TARY PUBLIC STATE OF FLORID OL (SEAESPERQN (SEAL) :•:��°�N•• PER Type of Identification produe ''. C�DES Type of Identification lir . ' d 1716 EXPIRES June 16,2014 EXPIRES June 16,2014 •�dbnwr. • JEFF ATWATER CHIEF FINANCIAL OFFICER STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS'COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: 5/9/2013 EXPIRATION DATE: 5/9/2015 PERSON: PEREZ ALEJANDRO FEIN: 201289530 BUSINESS NAME AND ADDRESS: PIRSA MIAMI CORP 13715 SW 84TH STREET#B MIAMI FL 33183 SCOPES OF BUSINESS OR TRADE: LICENSED GENERAL CONTRACTOR Pursuant to Chapter 440.05(14),F.S.,an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this sectinr,-ay not recover benefits or compensation under this chapter.Pursuant to Chapter 440.05(17.),F.S.,Certificates of election to be exempt...apply only within."•, :>,p of the business or trade listed on the notice of election to be exempt.Pursuant to Chapter 440.05(13),F.S.,Notices of election to be exempt and certificatof election to be exempt shall be subject to revocation if,at any time after the filing of the notice or the issuance of the certificate,the person named on the nai ce or certificate no longer meets the requirements of this section for issuance of a certificate.The department shall revoke a certificate at any time for failure of!nt person named on the certificate to meet the requirements of this section. DFS-F2-DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 07-12 QUESTIONS?(850)41;-1500 ,,eco 3/12 03/12/2001414 ® CERTIFICATE OF LIABILITY INSURANCE /DO `.� THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: C. Pan Am Assurance Agency, Inc PHOIC,NE (305) 270-1424 FAX No,.(305) 270-8997 9100 Sunset Drive EMAIL .carlos@panamassurance.com INSURER(S) AFFORDING COVERAGE NAIC# Miami FL 33173-3433 INSURER Amalachian Underwriters Inc INSURED Pirsa Miami Corporation INSURER 8: 13714 3W 84 Street INSURERC: Suite B INSURER D: INSURER E: Miami FL 33183- 1 INSURER F COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE POLICY EFF POLICY EXP LTR POLICY NUMBER MM/D MWD LIMITS GENERAL LIABILITY CG DS 01 10 01 1/13/2014 1/13/2015 EACH OCCURRENCE $ 1'000'000 X COMMERCIAL GENERAL LIABILITY / / / / DAMAGE TO PREMISES Ea NTEff occurrence) $ 100,000 }� CLAIMS-MADE OCCUR / / / / MED EXP(Any oneperson) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: / / / / PRODUCTS-COMP/OP AGG $ 2,000,000 X POLICY F PRO LOC / / / / DED LIABILITY $ 1,000 AUTOMOBILE LIABILITY / / / / COMBINED SINGLE LIMIT Ea accident ANY AUTO / / / / BODILY INJURY(Per person) $ ALL OWNED SCHEDULED / / / / BODILY INJURY Per accident) $ AUTOS AUTOS NON-OWNEDPROPERTY DAMAGE HIRED AUTOS AUTOS / / / / Per accident $ $ UMBRELLA LIAR OCCUR / / / / EACH OCCURRENCE $ EXCESS LIABCLAIMS-M ADE / / / / AGGREGATE $ DED I RETENTION$ / / / / $ WORKERS COMPENSATION I WC STATU- OTH- AND EMPLOYERS'LIABILITY _ ANY PROPRIETOR/PARTNER/EXECUTIVE Y/N / / / / E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? ❑ NIA — (Mandatory In NH) es, If E.L.DISEASE-EA EMPLOYE $ ydescribe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,H more space Is required) General Contractors CERTIFICATE HOLDER CANCELLATION (305) 795-2204 (305) 756-8972 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Miami Shores Village 10050 1E 2 Avenue AUTHORIZED REPRESENTATI E Miami Shores FL 33138- ACORD 25(2010/05) C 1988-2010 ACORD CORPORATION. All rights reserved. INS025(2olw5).ot The ACORD name and logo are registered marks of ACORD Local Business Tax Receipt Miami-Dade County, State of Florida -THIS IS NOT A BILL-DO NOT PAY 5535423 BUSINESS NAME/LOCATtON P RSA M IAM I CORP RECEIPT NO, 13715 SW 84 ST B RENEWAL EXPIRES MIAMI,FL 33183 5775888 SEPTEMBER 30, 2014 Must be displayed at Place of business Pursuant to County Code Chapter 8A-An.9&10 OWNER PIRSA MIAMI CORP SEC.TYPE OF BUSINESS 196 GENERAL BUILDING PAYMENT RECEIVED Worker(s) CONTRACTOR BY TAX COLLECTOR 1 CGC1508748 90-00 12/302013 This local Braixass Tax Receipt eely eenirrs , 0223-14-002682 pewit of a eertiiea6on of the holder's pnalife�bo���A`e Local Business Tax.The Receipt is not a license, ar loose-teetotal revelatory laws aad repairereet'to do b apply Holder r est cengly Wilk any governmental The RECER'T N0.shave 11831 he di pp Y the hnsineas. M displayed oa all commercial vehicles- For ren Inter nation, all Miari-Dade Code See 8a�276. w�1_Mia��3�tiivl e 1• ♦5NoRFs yi N..■ .....� Miami shores Village Building Department XOR 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT PERMIT#: /`f ® � DATE: d / Z (NAME) ontractor ❑ Owner ❑Architect Picked up 2 sets of plans and (other) / Address: e?6 /t(A) Is !74^ From the building department on this date in order to have corrections done to plans And/or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Department to continue permitting process. Acknowledged by: n� / 11 (Signature) PERMIT CLERK INITIAL: ad— RESUBMITTED DATE: PERMIT CLERK INITIAL: • 4 5tloeEs G!t Miami shores Village Building Department logo J_ � 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 IORiDA Fax: (305) 756.8972 Y "^ June 6, 2014 ` Permit No: RF14-1050 , �Yyss t Building Critique 1 . Pending structural and zoning approval. Ismael Naranjo, Building Official Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re-submittal drawings. ,SNORES G Miami shores Village 161Building Department � „ 111111" 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 ORIDp' Fax: (305) 756.8972 Page 1 of 1 Permit No: tL Structural Critique Sheet 'S co C,s. w� 'r,•- o�Ls ��j , t,o IL--t CU-42— G� r„r.e.& A C NDS r� STOPPED REVIEW Plan review is not complete,when all items above are corrected,we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re-submittal drawings. Mehdi Asraf SNpREs Gr! Miami shores Village Building Department logos, n1 � 10050 N.E.2nd Avenue Miami Shores, Florida 33138 L�Far �y� Tel: (305) 795.2204 ��OR1DP` Fax: (305) 756.8972 June 6, 2014 Permit No: RC14-1050 ELECTRICAL REVIEWER COMMENTS 1 . Need electrical permit application. Michael Devaney Chief Electrical Inspector Plan review is not complete, when all items above are corrected, we will do a complete plan review. If any sheets are voided, remove them from the plans and replace with new revised sheets and include one set of voided sheets in the re-submittal drawings. ,SHOC.193 RES r i I i 14 Miami Shores Village I Building Department artment �'�otitDP 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 MIAMI SHORES VILLAGE NOTICE TO BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER THE FLORIDA BUILDING CODE I(We)have been retained by " KI" to perform special inspector services under the Florida Buildi g Code at the project on the below listed structures as of 10 I (date).I am a registered architect or professional engineer licensed in the State of Florida. PR CESS NUMBERS:_ izt! 14 ❑ SPECIAL INSPECTOR FOR PILING,FBC 1822.1.20(R4404.6.1.20) ❑ SPECIAL INSPECTOR FOR TRUSSES>35'LONG OR 6'HIGH 2319.17.2.4.2(R4409.6.17.2.4.2) ❑ SPECIAL INSPECTOR FOR REINFORCED MASONRY,FBC 2122.4(R4407.5.4) ❑ SPECIAL INSPECTOR FOR STEEL CONNECTIONS,FBC 2218.2(R4408.5.2) 91 SPECIAL INSPECTOR FOR SOIL COMPACTION,FBC 1820.3.1 (R4404.4.3.1) ❑ SPECIAL INSPECTOR FOR PRECAST UNITS&ATTACHMENTS,FBC 1927.12(R4405.9.12) ❑ SPECIAL INSPECTOR FOR Note:Only the marked boxes apply. The following individual(s)employed by this firm or me are authorized representatives to perform inspection 3. 4. *Special Inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or licensure to perform the duties assigned by the Special Inspector. The qualifications shall include licensure as a professional engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program;successful completion of the NCEES Fundamental Examination;or registration as building inspector or general contractor. I, (we)will notify Miami Shores Village Building Department of any changes regarding authorized personnel performing inspection services. I, (we) understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site for reference by the Miami Shores Village Building Department Inspector. All mandatory inspections, as required by the Florida Building Code, must be performed by the County.The Village building inspections must be called for on all mandatory inspections. Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspections performed by the DepartmenkgWffth 1 V4M completion of the work under each Building Permit I will submit to the Building Inspector at the time of final in��t lowgi)plP.�40�jispection log form and a sealed statement indicating that, to the best of my knowledge, belief and profgNi P fyd@RWt j• Mons of the project outlined above meet the intent of the Florida Building Code and are in s with jt pl rpved plans. Si d Seale •; = Engineer/Architect Name « * (PRINT) ••• S�P�� "���` Address- p�,t�C�Q•••� �•L� �� Phone No. ` s FSSIOW": Created on 6/1d/md 19630 FRANJO RD. BOUNDARY SURVEY PHONE:(305) 283-0632 CUTLER BAY, FL. 33157 SCALE: 1" = 20' FAX: (305) 259-5769 30.00' 1 TIP 81.30'(R&M) QIP I (NO D) ; �O, 1/2" 1 d CBS O• NO ID) I WALL LOT 16 1/2 LOT 17 o BLOCK 131 UNAJ E BLOCK 131 o O W N Q Lo Y N � a of o I Nn 1 1 0Lj 10 `I 2L20 (BY. — �' I Q 3 ^ a4b5 G e Q a N Tri .4 I+L Z OI On O 000 J I � 3.80 .4. e' 40. `IJ 4.10 a. M co O �1 O m Q �� oi4 4. 0.4 N N O Mi . Z LLj QO i d O 37. 85 O NI I o C`t ONE STORY ; C.B.S. RESIDENCE N°95 z vO wuj �tj 00 u< wI v �� A/C F- m s 1 sl 1`�I 13.85 LO X O W CD N WLL- . Z 1 zO I 18.55 m 18.75 0111`' Wgx 1 Sao W O �F � o WLL Z�m Z Q t, QOO _ W ip Z CL o 0 OO Lj c d -� 02:�_- A Of W p U 1L d J J Q O LOCATION SKETCHo �1P RP Cb 1/2+ (N.T.S.) v2+ (NO ID) 70'(NO ID) 81.3 R&M 5.00' SWK sf.fl o,.. O N 3' 15.00' a 1�P12 PK/WY SP1- 19118 19 ZO 2172 Z3�24 .6 (NO ID) o C .-. .. •. I •. 00 130.Pa LOT 16 AND 1/2 OF LOT 17 b 2.0'GUTTER ii NW 95th STREET 48.00, (80.00' TOTAL R/W) rAvtmtNi a4m ON THE Fum INSURANCE RATE MAP OF THE FEDERAL EMEfma MAPMIpp,EM AGENCY GATEDosCERTIFIED TO FIELD WORK REVISIONS REVISED ON 09/11109 THE LEMON OESGRIM PROPERTY IS WUATED WMHIN ZONE x 61 RANA PAWING DAIS; 04/30/20 4 GATE; RASE FLOOD ELEVATION N/A COM MILOM-124l6z!Y PANEL.NUMBER 0302 SUFflX L NU WORD TIRE. LLC RIMS CERTIFIES THAT THIS SHWEY OF THE PROPERTY LEGAL NOTES FTDEIJTY NATIONAL Ti1LE INSURANCE COMPANY OCSWAW MOWN WAS MADE UIOER MY"BMW THIS SURVEY WES NOT REFLECT OR DETUME OMIERSIIP. EQUITY MORTGAGE RANKERS, LLC ARO THAT THE SAME MEETS THE MWWUM TECH IWX OWNNATON OF THE ABSTRACT OF TRE MLL HAAVEE TO BE MADE TO OEWWW RECORDED SWARDS SET FORM BY THE FIONON BOARD OF INSTRUMENTS,IF ANY,AFFECTING THE PROPERTY.THIS SURVEY IS SUBJECT TO OGWATKNIS, ITS SUCCESSORS ANO/OR ASSKiNS &M AYORS ANO MAPPERS IN CHAPTER 61017-6.FLORIDA LMRATONS,RESTRICTIONS,RESERIATONS OR EASEMM OF REWRD.LEGAL DESCRIPTIONS AOMH9IRATNE CODE,PURSUANT TO SECTION 472.027, PROVIDED BY CLEM.THE LVSLRY OF THIS AWAY IS LUTED TO THE COST OF THE SLIRWY. FLORIDA STATUTES. INOERGROLNO OICROACIMOM IF ANY.ARE NOT SOWL THIS FIRM INNS NOT ATTEMPTED TO LOCATE FwnNa ANO/OR FDUNOATONS AO/OR UEOERCRO m IMPROVEMENTS OF ANY NATURE.F SOWL SEARNOS ARE REFERRED TO AN ASSUMED M RDWL IF SOMI, ELEVAYWHS ARE REFERRED TO WONA OF 1629.THE CLOSIM N THE BOANOARY SURVEY IS ADM 1:10000.THIS SURVEY IS 1107 TRENDED FOR NERIER DESMON FOR OONSMRUMOH PlIRP06ES. FOR THOSE PURPOSES A TOPOOR"W SURVEY 6 RE000ED.FENCE OMNEWV HOT DETERMINED MIGUEL JESUS GARAY P.S.M 6594 This AIMy He not o0...°by PFDNANINNM labOV ORDER No. 14-129 IKN 1RLD MINOUT M RNONI10MNE AND M ONWIL MW NDL OF A FLOM NLDOW I N KNVR AND MIPPu LEGEND AND ABBREVIATIONS UA. .VILRY IVIL F.N. .FO{RD IPL FAA .POUND NOL A OW � -QSA MAL A/C .A caDncHm PM FAC. .DICROACH MNT MA +MOHAIR UE -//— .MOOD RNCE(6'NOLO OR.PY. OlA1Vw A .AMC OUfi1= F.H. .HIE NIOIMYR KONA .IAIINML O[OOEW VDOICAL OI11m R MOATS PAC. PONT OF 00006-000W NEO. +MAON G FTP. .FOND EON POE OS .O 1*00 DEQINC UNE p0• .ftvw P.C. .PONT OF CURVARM C.I. .CATCH 6AAN FAG. .FOUND 11MR PA .PEAT BOOK R[8. R ICE Co.. .CONCRM NECK STRUCRW ME .LOOM ROK OCM .COON PP. .PIT*~CONTROL POM -N— .OMAN LM PENCE(4'NON) CL .RfJNRmm Of lP. .UGHT POLE PA .PAGE YAC. .So:" 1MY 4 .cBam RINE CA -1DIIER UE P.OA. -POM OF 68010ID Sly .STONY car. +00Na1[TE (R t PO +REDOW t WARM PA .FROPOW UNE SMte .90EMMK OME .OODUAOE MWE ARM Vdaeff .GLA1O1011 N.T.S. .FOC TO so" r 19630 FRANJO RD. BOUNDARY SURVEY PHONE:(305) 283-0632 CUTLER BAY, FL. 33157 SCALE: 1" = 20' FAX: (305) 259-5769 I 30.00' 17P 81.3 0'(R&M) FIP ff (NO 0) : �O, 1/2" d CBS o•. NO ID) WALL 1/2 LOT 17 LOT 16 LOT BLOCK 131 o BLOCK 131 Lci INE o C4 o 3 o F- w /( 14 II Ld _ Q31 2L20 I I n. ' �I Q F_ 2`4.65 d• . Q o 0� I \ a a lu °0 s . 11 ZofQ D tu oS jY O F-•O 3.80 a o A.d . -0 '" . D m O �i o A N� N F-Z \� O vi d e. .'as . • 4. 9.82' g 37.85 oz � m n2 ONE STORY z C.B.S. RESIDENCE Soo �W{ N°95 L . w m UNf J Wp I V I " A/C WI } F-Qm U)I m OJ 1385 tl o O S LO O LAI In In . OD N N W LL- -W W Z( c r. O 18.55 18.75 9.82 r In � Ld W Sao U W HHS Z m U Q 0 D o O W ca Z(L 0 o LL1 g a Ld d J Q O A of W 0 u- n. J Jao LOCATION SKETCHo nP FJP �d 1/2" (N.T.S.) 1/2- (NO 10) 8 1.3 0' R&M 5.00' SWK (NO ID) ,15 WO Iz 1 ID 9 8{ 7 z; r ! 15.00' ,� RP PK/WY N- 17I!8 19 ZO 21 2Z 23 24 5 _ 1/2� (NO ID) o � 0._.n I .. ' .. .. leo I30.Gp1� LOT 16 AND 1/2 OF LOT 17 2.0'GUTTER iii — — ---PAVEMM NW 95th STREET 48.00, (80.00' TOTAL R/W) BALD ON TK FLOOD MSUIRANC E RATE MAP OF THE FEDERAL EMERWNT MANAMIIE NT AGENCY DA70 OF CERTIFIED TO: FIELD WORK REVISIONS REVISED ON 09111/09 THE FINN DIESO Im PROPERTY IS STRIATED WTTIN ZONE x BIBIANA PATINO DATE: 04/30/20 4 DATE: BASE FLOOD ELEVATION _NLA_COEMAUWTY 12=PANEL!TIMBER 0302 SUFFW L NU WORLD 1TTLE, LLC TNIS CERTIFIES THAT THIS SURVEY OF THE PROPERTY LEGAL NOTES FIDELITY NATIONAL TTT E INSLIRANC£COMPANY OESCWED HEREON WAS MADE UNDER W SUPER WISION 1N5 SURVEY DOES NOT REFLECT OR DETERMNE OWERSIMP. EOLMY MORTGAGE OMIXERS. LLC AM THAT TW SAW MEETS TE WWNAW TJCNNCAL STANDAO MMIM OF TIE ABWT OF TITLE WILL NAVE TO K MADE TO DETERMINE RECORDED IDS Foam MY FLORIDA HOAR-OF I6(RtMORS.IF ANY,AFTECTIIC THE PROPERTY.THIS SURVEY 6 SIIfiECf ro oEDICATI0N5, fI5 SUCCtSSORS AND/DAR ASSIGNS WAVEYORS N� N IN 04AP1ER e1017-6.FLORIDA LRRFATIONS,WOODROW.RFSEI M 706 OR EAMIEMS OF RECORD.LDDAL oESCCAPIIIOI6 I E CODE.PURSRW/f ro SEC710NI 472.027. FLORIDA 9FAUES. PRDVIOED BY CLR]If.THE 1LABIJIY OF TIS SWIVEY 6 tAnED TO THE COST OF THE SURVEY. IIDEROROLMD ENCROACHMENTS.IF ANY.ARE NOT SHOWL TM FIRM IAS NOF ATTEIFIED TO LOCATE FOOTM AND/OR FOIMM106 NTD/OR UNDERGROUND IIPROVEHENS OF ANY NATURE F S OO.BEARINGS APE REFERRED TO AN ASSUMED MERIDIAN.IF SHOWN. ELEVATORS ARE REfERED TO N.O.VD.OF 1DYD.THE CLOSURE W TW MOUIOARF SURVEY IS - ADOVE IAODDD.THE SU WY 6 NOT INTENDED FOR NEM*R DESIGN FOR`aa'RUCTION aRm°SES' MIGUEL JESUS GARAY P.S.M 6594 FOR THOSE PURPOSES A TOPOGRAF411C SURVEY 6 IEOINRED.FENCE OWIERSNIP NOT DETERMINED TMI,x-y Ib Amt Car..d'by Pa.•I«md ORDER No. 14-12 NOT We WHOUT THE SAMM AMO RR:DAIOMML IMNI u OF A MOM UCOOm■*am AID NIPFDI LEGEND AND ABBREVIATIONS ""mIIO ""m/IT OONDITIO W10 PAD F -CA LS. IJIpIMOI1Wf //---NA MON MEW I" WX FUM I'm FAA SUM IV&&DISK wow NWL � (I'MION) ORWI.� TRIC OIRYEENY A .AMC DOIAWE F.N. .FK W~ N.QVD. .W OINL GEODETIC VORTICAL WW R IMDMIS PA.C. .POM OF ODNKN-COOT KOM .EIRIDMD FAP. .FOUND OUR PPE OL OVDINEAD ELECTRIC LIE pp .MACK P.0POW OF CIRlVA71IE CAL .OUCH am F.I.R. .FTNAp NOW P.& no DOOM RFS. .RSIDIM CAL ca"CETE 0=SRUCIURE IF.6 LORnT Kom OE AM P.C.P. PEIUMFOIF COMROL POM -R— -OMR LAK FORCE(4'MOND CL .RFMS LP. .UONF POLE PA. .WOE C = WAY A .CORRAL AIME CA .CORER LINE P.OA. .POM OF NDMMD MY .SIMV CONC. .OOIIGEE (R t ADDOID k MEATUED PA PROPERTY UE SDERMK 01E fRDINOE 1MIIIV7WIR oR0lM .alw4ION N.T.A .NOT TO BOND CFN: 20140335116 BOOK 29144 PAGE 4132 DATE:05/09/2014 11:05:18 AM DEED DOC 1,875.00 HARVEY RUVIN,CLERK OF COURT, MIA-DADE CTY Prepared By and Return To: Karina Zuleta Nu World Title,LLC. 3785 NW 82 Ave,Suite 403 Doral,FL 33166 File No. 141253 Properly Appraiser's Pamel 1.11(fblio)Nurnber(s) 11-3101-033-0540 WARRANTY DEEB THIS WARRANTY DEED dated May 1,2014, by Rolando Hernandez a married man,whose post office address is 16765 NW 86th Court, Miami, FL 33016, hereinafter called the grantor, to Sibiana Patino a married woman, whose post office address is 95 NW 95th Street, Miami, FL 33150, hereinafter called the grantee: (Wherever used herein the terms "grantor" and "grantee" include all the parties to this instrument and the heirs,' legal representatives and assigns of individuals, and the successors and assigns of corporations) WITNESSETH: That the grantor,for and in consideration of the sum of$312,500.00 and other valuable consideration, receipt whereof is hereby acknowledged, hereby grants, bargains, sells, aliens, remises, releases, conveys, and confirms unto the grantee, all the certain land situated in Miami-Dade County, Florida,to wit As shown on Exhibit which is attached hereto and incorporated herein by reference. Subject to easements, restrictions, reservations and limitations of record, if any, TO HAVE AND TO HOLD the same in Fee Simple forever. AND the grantor hereby covenants with said grantee that the grantor is lawfully seized of said land in-fee simple; that the grantor has good right and lawful authority to sell and convey said land; that the grantor hereby fully warrants the We to said land and will defend the same against the lawful claims of all Persons whomsoever; and that said land is free of all encumbrances, except taxes-accruing subsequent ID: December 31, 2014 Wwwty Owd OndviWii to trovidual � a CFN: 20140335116 BOOK 29144 PAGE 4133 WARRANTY DEED (Continued) IN WITNESS WHEREOF, the said grantor has signed and sealed these presents the day and year first above w ritten. ivered in the presence of. ;! natu ) Rol. emande i` 16765 NW 86th Court yk (Address) (Witness rej Miami, FL 33016 (Address) STATE OF Florida COUNTY OF Miarni-Dade 1, Karina Zuleta, a Notary Public of the County and State first above written, do hereby certify that Rolando Hernandez personally appeared before me this day and acknowledged the due execution of the foregoing instrument. Mmy hand an o ial seal,this the 1 st day of May, 2014. Public My Commission Expires_ KARINA ZULETA v r, MY COMMISSION#EE085381 (SEAL) EXPIRES Apr#18,2015 ase�►tsa Rorwdromiysen,ieecom watrapti Dwd(Indmus b Nwirkksp `51%URFs 7 R ,,...v rami Shopeli Villa e -TE it®,,� 10050 N.E. SECOND AVE. �LORlDA MIAMI SHORES, FLORIDA 33138-2382 Telephone: (305) 795-2207 Fax: (305) 756-8972 DAVID A. DACOUISTO, AICP PLANNING&ZONING DIRECTOR DEVELOPMENT ORDER File Number: PZ-3-14-201486 Property Address: 95 NW 95 Street,Miami Shores,FL.33150 Property Owner/Applicant: Rolando Hernandez and Bibiana Patino Address: 95 NW 95 Street, Miami Shores, FL.33150 Whereas, the applicant Rolando Hernandez and Bibiana Patino, (Owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Special site plan review and approval. Addition, covered terrace. Whereas, a public hearing was held on April 24, 2014 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted as shown on the plans submitted and made a part of this approval to construct a 300 sq. ft. flat roof covered terrace. 2) Applicant to obtain all required building permits before beginning work. 3) Applicant to obtain all required permits and approvals from the Miami-Dade Department of Regulatory and Economic Resources,Environmental Plan Review Division(DRER, EPRD) and the Miami-Dade Department of Health (DOH/HRS) as required. 4) Applicant to meet all applicable code provisions at the time of permitting. Pagel of 2 DO PZ-3-14-201486 Hernandez 5) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. The application with conditions was passed and adopted this 24th day of April, 2014 by the Planning and Zoning Board as follows: Mr. Abramitis YES Mr. Busta YES Mr. Reese YES Mr. Zelkowitz ABSENT Chairman Fernandez YES X? Date T7 and M. Fernandez,' hairman,Planning B and r Page 2 of 2 DO PZ-3-14-201486 Hernandez �SHoREs Dr J R I logo �_ Ilium?' Miami shores VillageIBY: _- Building Department ��ORIDp' SRC F TXTFD 10050 N.E.2nd Avenue Miami Shores, Florida 33138 JUN 1 1 2014 j Tel: (305) 795.2204 Fax: (305) 756.8972 BY: VILLAGE NOTICE TO BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER THE FLORIDA BUILDING CODE I(We)have been retained by F�l T:� ­ to perform special inspector services under the Florida Buildi g Code at the c project on the below listed structures as of (date). I am a registered architect or professional engineer licensed in the State of Florida. PR CESS NUMBERS: 1Z ry ❑ SPECIAL INSPECTOR FOR PILING,FBC 1822.1.20(R4404.6.1.20) ❑ SPECIAL INSPECTOR FOR TRUSSES>35'LONG OR 6'HIGH 2319.17.2.4.2(R4409.6.17.2.4.2) ❑ SPECIAL INSPECTOR FOR REINFORCED MASONRY,FBC 2122.4(R4407.5.4) ❑ SPECIAL INSPECTOR FOR STEEL CONNECTIONS,FBC 2218.2(R4408.5.2) 12 SPECIAL INSPECTOR FOR SOIL COMPACTION,FBC 1820.3.1(R4404.4.3.1) ❑ SPECIAL INSPECTOR FOR PRECAST UNITS&ATTACHMENTS,FBC 1927.12(R4405.9.12) ❑ SPECIAL INSPECTOR FOR Note:Only the marked boxes apply. The following individual(s)employed by this firm or me are authorized representatives to perform inspection 3. 4. *Special Inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or licensure to perform the duties assigned by the Special Inspector. The qualifications shall include licensure as a professional engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program;successful completion of the NCEES Fundamental Examination;or registration as building inspector or general contractor. I, (we)will notify Miami Shores Village Building Department of any changes regarding authorized personnel performing inspection services. I, (we) understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site for reference by the Miami Shores Village Building Department Inspector. All mandatory inspections, as required by the Florida Building Code,must be performed by the County.The Village building inspections must be called for on all mandatory inspections. Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspections performed by the Department. Further, upon completion of the work under each Building Permit I will submit to the Building Inspector at the time of final inspection the completed inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and professional judgment those portions of the project outlined above meet the intent of the Florida Building Code and are in substantial accordance with the approved plans. Signed ago6eale4ii,, Engineer/Architect \WEZ-/,o Name E' #��'1 r-.C� )4 .. rrrr •• 4% Address 71 4,0 .� w •' V �i��20# •• • W — Phone No. • �� : Q • of LU - (.e e*Qn 6l'I tC9 •. L0 IsssloN R �F Y,J 7 x+„ f ',4: tri� ✓ 1 4; Y.c� 1 i r Y yg. 4 � � M i7 7:7— .? Maim TERRACE ADDITION FOR . . .... ...... MR. ROUNDO UERNANDEZ :::::: ': • .... :6 .... • •• ••:•.• 95 N.W. 95TU. ITREET, MIAMI 11HOREl, EL. J05'NUMBER CONSULTING ENGINEERS, P.A CIVIL /STRUCTURAL U-016-0" FE.22249 CAOM5512 1220 5111.391h TEWACE MIAMI,FLORIDA 33153 TEL- (305)262-6225 FAX-005)262-2014 E-mail: crlar6cfcr4,un+bellaca:t},net ORLANDO M. FORTUN CONSULTING ENGINEERS P.A. O 7220 S.W. 39TH. TERRACE, MIAMI, FL. 33155 �p P.E. NO. 22249 CA- 0005512 O project number 14-016-029 project name HERNANDEZ' TERRACE ADD'N 95 N.W. 95TH. ST., MIAMI SHORES, FL. J AS PERMITTED BY FLORIDA ADMINISTRATIVE CODE, SECTION 61615-23.002(2) THIS COVER PAGE HAS BEEN SIGNED,SEALED AND DATED ASSUMING RESPONSIBILITY FOR lU 10 PAGES OF THE RESPONSES AND CALCULATIONS LISTED BELOW: TABLE OF CONTENTS —e �` W MARK D E S C`R I P T I O N PAGES OF Z DESREF DESIGN REFERENCES D-1 • P.•••�,��` F NP DESLDS DESIGN LOADS D-2 11 WIND LDS. DESIGN OF ROOF WIND UPLIFT LOADS 1 0% ROOF JOISTS DESIGN OF ROOF JOISTS 2 TO 3 _ Z ROOF BEAMS DESIGN OF ROOF BEAMS 4 TO 5 � g oC IL BLOCK COLUMN DESIGN OF BLOCK COLUMN 6 TO 7 N 4 W FOUNDATION DESIGN OF FOUNDATION 8 z O W S uU1 • • • • •• M 00 00 •• • v • .. b 0 Q w V Q CC W H 0� N O MecaWind Pro v2 . 2 . 3 . 5 per ASCE 7-10 'o Developed by MECA Enterprises, Inc. Copyright www.*neca'ntercrise3.c"m r -- -==- O Date 5/11/2014 Project No. 14-016-029 �( Company Name : ORLANDO M. FORTUN, CONS. ENGS. Designed By : O.M.FQRTUN, P.E. ry Address 7220 S,W, 39TH, TERRACCE, Description TERRACE ADDITION r j City MIAMI Customer Name ROLANDO HERNANDEZ t / State FLORIDA Proj Location 95 N.W. 95TH. ST. MIAMI SHOR S Input Parameters: Directional Procedure All Heights Building (Ch 27 Part 1) LL BasicWind Speed(v) = 175.00 mph Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure No LW U Importance Factor = 1.00 Kd Directional Factor = 0.85 Alpha = 9.50 Zg = 900.00 ft O At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 0.2499311 12 Slope of Roof(Theta) = 1.19 Deg Ht: Mean Roof Ht = 10.15 ft Type of Roof = MONOSLOPE RHt: Ridge Ht = 10.30 ft Eht: Eave Height = 10.00 ft OH: Roof Overhang at Eave= 1.50 ft Overhead Type = Overhang Bldg Length Along Ridge 19.50 ft Bldg Width Across Ridge= 14.50 ft Gust Factor Calculations (�J� Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use.0.85 = 0.85. Gust Factor Category II Rigid Structures - Complete Analysis In Zm: 0.6*Ht = 15.00 ft lzm: Cc*(33/Zm)^0.167 = 0.23 Lzm: 1*(Zm/33)^Epsilon = 427.06 ft 3 Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.95 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)} = 0.90 Z m M Gust Factor Summary C,) Not a Flexible Structure use the Lessor' of Gustl or Gust2 = 0.85 Q IL a ) Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi d GCPi Internal Pressure Coefficient = +/-0.55 Q 41333 W Reduction Factor for Large Volume Buildings, Ri INC 9F. Aog: Total Area of Openings in Bldg Envelope = .00 ft^2 Z `r Vi: Unpartitioned Internal Value _ .00 ft^3 &. V A Ri: 0.5*((1+1/(1+(Vi/(22800*Aog))^0.5)) (Egn. 6-16) = 1.000 LU Notes.: 1) +GCpi = +0.55 Ri IL Notes: 2) -GCpi = -0.55 * Ri O s Wind Pressure on Components and Claddinggno •• n i ;h, 1. Zre. �.,t•d s. g , ... r_ a -_ a-: t.r • • ii Width of Pressure Coefficient Zone "a" _ = 3.00 f�•�••• ••• a Description Width Span Area Zone Max Min Max P •Idn•P• • ft ft ft^2 GCp GCp psf •pat•• ,•, aC ----------------------�----------------------------------- JOISTS 1.33 14.50 70.1 1 0.22 -0.92 25.98 •r94,7.4) • •.�••• 1.33 14.50 70.1 2 0.22 -1.21 25.98 -59.6*7 ••• +• 1.33 14.50 70.1 3 0.22 -1.36 25.98 "64.*91 • V •••••• LL • • Q W cc w 1 ~ ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title: 7220 S.W.39TH.TERRACE, Engineer: Project ID: MIAMI FLORIDA 33155 Project Descr. CA-0005512 ORLANDO M.FORTUN N P.E.22249 SP.INSP.369 P:r yaw_ 14.2:46PM Wood BeamFile 0Users\0RLAND-100CUME-11EN 114F9 ENERCALC,INC.1983-2014,Bui 26,Ver.6.14.1:26 r.00. ORLANDO M.FORTINs Description: 14-016-029 JOISTS 2 X 12 @ 16 ' CODE REFERENCES -------------- ----- Calculations per NDS 2012, IBC 2012, CBC 2013,ASCE 7-10 Load Combination Set ASCE 7-10 Material Properties Analysis Method: Allowable Stress Design Fb-Tension 1350 psi E:Modulus of ElastiAlli Load Combination ASCE 7-10 Fb-Compr 1350 psi Ebend-xx W 1400ksi Fc-Prll 1600 psi Eminbend-xx O 510ksi Wood Species : Southern Pine Fc-Perp 480 psi _ Wood Grade : :No.2 Non-Dense: 2"-4" Thick 2" 4 Fv 175 psi Ft 775 psi Density 15.44pcf Beam Bracing : Beam is Fully Braced against lateral-torsion buckling Q 1)(0-030)Lr 0:040 —T--- — -- --r�_S--- • —" 2x12 UIx 2 Span=14.50 ft E 3.0 ft ZWIL Applied Loads _ _ Service loads entered. Load Factors will be appl c IctiQos. o .------- - ---- - - - -00 a - Beam self weight calculated and added to loads Loads on all spans... X11 0 u Uniform Load on ALL spans: D=0.030, Lr=0.040 klft p DESIGN SUMMARY • n Maximum Bending Stress Ratio = 015021 Maximum Shear Stress Ratio = Z3. 5 °� Section used for this span 2x12 Section used for this span p( 2 1 fb:Actual f :Actual W 9 u FB:Allowable 1,350.00psi Fv:Allowable X 17 Otos Load Combination +D+Cr+H. Load Combination C r Location of maximum on span = 6.966ft Location of maximum on span .. 360 Span#where maximum occurs = Spam#1 Span#where maximum occurs. '.. a # ..... Maximum Deflection •• • Max Downward L+Lr+S Deflection 0.145 in Ratio= 1203 .•.... '.. or Upward L+Lr+S Deflection -0.085 in Ratio= 848 ...;.. Max Downward Total Deflection 0.268 in Ratio= 649 • • • Max Upward Total Deflection -0.157 in Ratio= 456 • • • _ Ll. Overall Maximum Deflections•Unfactored Loads Load Combination Span Max.""Defl Location in Span Load Combination ' lv�ax."+'�efl. tion in pan D+Lr 1 0.2681 7.209 •••` i 0.0000• T 3,;w 2 0.0000 7.209 D+Lr -0.15723.000 Vertical Reactions-Unfactored Support notation:Far left is#1 Values in KIPS Q Load Combination Support 1 Support 2 Support 3 INC Overall MA)Cimum 0:515 ---0.783 ----_ ___ _ .W Overall MINimum 0.237 -0:361; V D Only rVM 0Mr 0 8 1 0240.27 Lr Only D+Lr 0.515 0.783 3 �,r t ! W GO TO ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title: 7220 S.W.39TH.TERRACE, Engineer: Prosect ID: MIAMI FLORIDA 33155 Project Descr: CA-0005512 ORLANDO M.FORTUN O N P.E.22249SP.INSP.369 Pr;to +Av a 2asPM WOOC� @1fY1 Fife=caUsersIORLAND-11DOCUME-11EN -114F9F ENERCALC,INC.1983-2014,Build: 1 6,Ver.6.14.1.26 i.1�. 12 Licensee ORLANDO M.FOR"7 • Description: 14-016-029 JOISTS 2 X 12 @ 16 l.a 1.3 OJ LL ItsN F 0.2 BEAM.-sem -0.3 1.62 3.32 5.02 - 6,72 8.42 10.13 11.83 13.53 IS 16.91 . Distance(ft) - ■+D+H �9+ ■+D+S+M ■+D+0.75D .+D.7SD +H + +D.75DS+H 2D40.60W+H +D+0.70E+H D+D.7S00+0.7S0L+DAS0W+H ■+D+D.7SDL+D.7Sb5+D.4SDW+H ■+D+0.75DL+D.7SD5+0. C 6DW+D.6DN ■+0.60D+0.70E+0.6DH - 0.5. 0.3 �t BEAM- .03. LL r 1.62 - 3.32 SAY 6.72 8.42 10.13 11.83 13.53 S Distance(ft) . ■+D+H. ■+D+L+N ■+D+L-+H ■+D+S+H ■+D+0.75 D L.+D.7SDL+H !+D D +D. I +D+D.BOW+M f+D+D.70E+H ■+D+D.75 DI�+D.7SDI+D.dSDW+H ■+D+D.TSOL+D.7565+0 ASDW+H l+D+0.T50L+D.TSD5+D.52SDE+H/+DD D + /+D.6DD+D.70E+6.6DH. 0.16 m e m 0 i BEAM W $y w m os7n. 1.62 3.32 5.02 6.72 8,42 10.13 11.83 1353 '1 .6 9 Distance(ft) O a DO-N/L-a•1„/o+L' 93 r •• O •• • . J • U. • . •••••• •• . . • • Q Q GL DL w F- ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title: 7220 S.W.39TH.TERRACE, Engineer: Proiect ID: MIAMI FLORIDA 33155 Project Descr: CA-0005512 ORLANDO M.FORTUN N P.E.22249 SP.INSP.369 P 0I -MA_ ia,zszpPa COIICrete B@altl File=caUserslORLAND-11DOCUME-11EN 114F9 ENERCALC,INC.1983-2014,Bui . 26,Ver: .14-26 0.00. ORLANDO M.FORPCO Description: 14-016-029 ROOF BEAMS RB-1,2,3 CANT. qt K51 CODE REFERENCES Calculations per ACI 318-11, IBC 2012,ASCE 7-10 Load Combination Set,ASCE 7-10 j Material Properties _ _ _ U_ fc 1/2 = 3.0 ksi Phi Values Flexure: 0.90 fr= fc ' 7.50 = 410.792 psi Shear: 0.750 yf Density = 145.0 pcf R 1 = 0.850 k LtWt Factor = 1.0 Elastic Modulus = 3,122.0 ksi Fy-Stirrups 40.0 ksi fy-Main Rebar = 60.0 ksi E-Stirrups = 29,000.0 ksi E-Main Rebar = 29,000.0 ksi Stirrup Bar Size#_ # 3 Number of Resisting Legs Per Stirrup= 2 • Load Combination ASCE 7-10 .",, ' FROM yj IC'y 8 in 0 0.270 Lr 0.320 i 8"w x 12"h - .. 8"w x 12"h Z8' Nx 2" 6 .Span=10.Oft - Span=10.0 ft WY3 Bn=3.01p p 4 0 LL Cross Section&Reinforcing Details Rectangular Section, Width=8.0 in, Height=12.0 in Zz Span#1 Reinforcing.... O n 245 at 2.50 in from Bottom,from 0.0 to 10.0 ft in this span 245 at 2.50 in from Top,from 0.0 to 10,0 ft in this s ~s Span#2 Reinforcing.... W L)uii S 245 at 2.50 in from Bottom,from 0.0 to 10.0 ft in this span 245 at 2.50 in from Top,from 0.0 to 1.0.0 ft in this s a- Span#3 Reinforcing.... Q 245 at 2.50 in from Bottom,from 0.0 to 3.0 ft in this span 245 at 2.50 in from Top,from 0.0 to 3.0 ft in this • (off Applied Loads Service loads entered.Load Factors will be appt C1CffAt1dh;!' Loads on all spans... - --- •• •• �� IV D=0.270, Lr=0.320 •• �•• ••Uniform Load on ALL spans: D=0.270; Lr=0.320 k/ftDESIGNSUMMARY Maximum Bending Stress Ratio = 0.394: 1 Maximum Deflection Section used for this span Typical Section Max Downward L+Lr+S Deflection ••;•U009 in: 1291 b•••- Mu :Applied -9.51 Q k-ft Max Upward L+Lr+S Deflection •• •t�.002 in•R 36022••:• Mn'Phi:Allowable Max Downward Total Deflection ••••0017 in R - 7002 • 24.116 k-ft Max Upward Total Deflection : •-0;004 in•R t+z= 195969*:* Load Combination +1.20D+1.60Lr+0.50L+1.60H .. O• - Location of maximum on span (][Zoft .0. �-I .....: Span#where maximum occurs Span#2 •• 1f'! • Cross Section Strength&InertiaTop&Bottom references are for tension si ++2's n ----- -- ---- --------------- ------ -- -- - --- ----- - Max Mu (k-ft) Phi'Mn (k-ft) Moment afte tia (in^4) Cross Section Bar Layout Description Bottom Top Bottom Top I gross 03c tom Icr-Top Section 1 2-#5 @ d=9.5",2-#5 @ d=2.5", 0.00 0.00 24.12 24.12 1,152.00 1 .57 316.57 Section 2 2-#5 @ d=9.5',2-#5 @ d=2.5', 0.00 0.00 24.12 24.12 1,152.00 1 .57 316.57 Section 3 2-#5 @ d=9.5",2-#5 @ d=2.5", 0.00 0.00 24.12 24.12 1,152.00 W1 .57 316.57 Vertical Reactions-Unfactored Support notation:Far left is#1 - --- --------------------------------------- ------------------------ -- --------- Load Combination Support 1 Support 2 Support 3 Support 4 Overall MAXimum 2.279 6.977 4.314 GO TO Overall MINimum 1.043 3.193 1.974 m ' D Only 1.043 9 1.974 _ j ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title: 7220 S.W.39TH.TERRACE, Engineer: Project ID: MIAMI FLORIDA 33155 Project Descr: _ CA-0005512 GO TO tr ORLANDO M.FORTUN P.E.22249SP.INSP.369 € _ P101 'AAY ,1a,r52PN1 Concrete Beam File=c:Wsersk0RLAND-11D0CUME-11E 1114F9 ENERCALC,iNC.19832014,Buil. 26,Ver.6.14.1•.26 066I1. - ORLANDO M.FORT64 • Description: 14-016-029 ROOF BEAMS RB-1,2,3 CAt T. Vertical Reactions-Unfactored Support notation:Far lett is#1 Load Combination Support 1- Sup rt 2 Support 3 Support 4 Lr Only 1.23,6 --- ---2.340 - ----- - - D+Lr 2.279 6.977 4.314 LL Overall Maximum Deflections-Unfactored Loads Load Combination Span Max.""Defl Location in Span Load Combination Max."+"Defl L cation in Span D+Lr --- --- -.1 .---- 0.0171 - ---- 4.250 D+Lr _.. _----------__ _-0.0001 it D+Lr 2 0.0090 5.750 D+Lr -0.0002 O 10.075 3 0.0000 5.750 D+Lr -0.0037 N 3.000 6 SH 2 .. BEAM­_ - .2.17 -- 4.42 6.67 8.92 11.17 13.42 15.67 17.92 zL23 22.48 Distance(n) r� •+1.40D+1.60N- - ■+1.26 D+6.SDL�+1.60 L+1.60H ■+1.ZDD+1.60L+D.SDS+1.&OX ■+1.LDD+S.BQL�+6.5DL♦1.60M •+1.200+1.6DL,+D.SOW+1.66" •+ AM+ .SOL *'A+1.ZOD+1.605+O.SOW+1.66H •+1.ZOD+D.SOL-+D.SDL+W+1.60X•+1.20D+O.SOL+O.SDS+W+I.6DH ■+1.ZDD+O.S DL+D.26S+E+1.66" ■+O.9OD+W+0.9DH ■+ .4DD+ +0. OX 5 2. BEAM- 5 - - 2.17 4.42 8.92 11,17 13.42 15.67 17.92 0 2 T�� kl DL S� Distance(rt) A�, ■+I 4DD+1.60H ■+1.2 OD+O.SOL�+1160L+1,60H ■+1.LOD+1.601+O.SDS+I.6DH ■+1.2 DD+1.60 L�+D.SDL+1.60M 9+1.ZDD+I.6DL'+D.SDW+LSOH •+1 50 +1. OM Y1 'd+1.20D+1,bD5+O.SDW+I.BDH •i1.2DD+D.S DLA+O.SDL+W+1.66H•+1.26D+D.5 DL+0.SDS+W+1.6 D" ■+1.2DD+D.SDL+D.2D5+E+1.bDH. •+D.9DD+W+D.40M f+ + +D D" U1 .m.. m U1 as 0.004 0 r BEAM...» -0.002 -0.007 • • • -0.012 i _T • • • • Y• -0.017 :.1,25 32S 5.25 7.25 9.25 12.25 14.25 16.25 •111..••: 20.4• �• 1.88 09901.00 Distance(R) - •• •• • •••••• •DO-ly•D+L-■DO-ly■L-0-1y•D+Lr ;L ' Z0.0000 _ •• .. .. o 0 a W V Q CL DL W H ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title: 7220 S.W.39TH.TERRACE, Engineer: Project ID: MIAMI FLORIDA 33155 Project Descr. CA-0005512 .6 ORLANDO M.FORTUN N P.E_22249SP_INSP.3fi9Pr qi MAY ,a 259PM MaSOt1 CO�U(1tn File=c:\Users\ORLAND 1\DOCUME-11EN 114F9F Masonry ENERCALC,INC.1983-2014,Buil 6,Ver.6.14.1.26 0.00. ORLANDO M.FOR T,94 COt'GL;L-.;;;G Description: 14-016-029 BLOCK COLUMN 12 X 12 4 .a Code References Calculations per ACI 530-11, IBC 2012, CBC 2013,ASCE 7-10 Load Combinations Used :ASCE 7-10 General Information _ _ _ I. Materia!Properties Column Data -------- ----Analysis Settings ----- ---_--- N - ----- F'm = 1,500.0 psi Column width along X-X = 11.625 in Analysis Method = Working Str Q sign Fr-Rupture = 75.0 psi Column depth along Y-Y = 11.625 in O Em=fm* = 900.0 End Fixity Condition = Top Pinned, Pinned Column Density = 130.0 pcf Longitudinal Bar Size = # 5 0 Overall Column Height - 10.0 Bars per side at+Y&-Y = 2 Rebar Grade = Grade 60 Construction Type Solid Grouted Holncrete Masonry Fy-Yield = 60000 psi Bars per side at+X&-X = 2 Fs-Allowable = 32,000.0 psi Cover from ties 3.50 in Tie Bar Size = Al 3 E-Reba = 29,000.0 ksi Actual Edge to Bar Center= 4.1875 in Tie Bar Spacing = 8.0 ill 2 Load Combination= ASCE 7-10 2 Brace condition for deflection(buckling)along columns: X-X(width)axis: Fully braced against buckling along X-X Axis Y-Y(depth)axis: Fully braced against buckling along Y-Y Axis N Applied Loads Service loads entered. Load Factors will be appl f r calculations_ Column self weight included 1,220.021bs*Dead Load Factor H AXIAL LOADS. FROM Axial Load at 10.0 ft'ID=3.190, LR=3.784 k�_.._'_m�w.=. BENDING LOADS. . . DESIGN SUMMARY ..Z_ Bending&Shear Check Results IL1 o s PASS Maximum Bending Stress Ratio = 0.108 :1 Maximum SERVICE Load Reactions- Load eactions-Load Combination +D+Lr+H Top along X-X 0.000 k � l Location of max.above base 0.000 It Bottom along XA 0.000 k At maximum location values are... u1 W Axial-Applied 8.194 k Maximum SERVICE Load Deflections... Axial-Allowable 75.997 kI Along x-x 0.000 in atff Moment-Applied 0.000 k-ft for load combination WU W Moment-Allowable 2.248 k-ft g IL m PASS Reinforcing Area Check (ACI530-11,Sec 3.3.4. Compressive Strength 76.004 k (AG Ot e 3.3® F Pa=(0.25 fm An+0.65 Astfs) '[1-(h/(140*r))12] • o As:Actual Reinforcement 1.240 • Min:0.0025*An 0.338 PASS Check Column Ties (4 4 2.lV • •• ••••• Max:0.04'An 5:406 Mm.Tie Dia=114",#3 bar provii e& �• • Dimensional Checks Max Tie Spacing= 10.00 in,PjQvV"= 8.00 itt Q• 91 Min.Width/Depth>=8" (ACI 530-11,Sec 3.4.4. •••••• • PASS Overall Height/Min Dim-25 (AC1530-11,Sec 3.4.4. Go** •r Load Combination Results _ _ •••• Maximum Bending Stress Ratios Maximum Axial Load .. •• MAN i ments•••••• Load Combination Stress Ratio Status Location Actual Allow ,..•.. Actual IL Allow .� +D+}{ 0.0580 PASS 0.0 ft 4.410 k 75:997 0.0 2.848 k-ft• +D+L+H 0.0580 PASS 0.0 ft 4.410 k 75.997E •• 0.0 2.:44 i-tt, +D+Lr+H 0.1078 PASS 0.0 ft 8.194 k 75.997 k" 01 2.248 k-ft +D+S+H 0.0580 PASS 0.0 ft 4.410 k 75.997 k 5110, 2.248 k-ft +D+0.750Lr+0.750L+H 0.09533 PASS 0.0 ft 7.248 k 75.997 k 0.0 2.248 k-ft +D+0.750L+0.750S+H 0.0580 PASS 0.0 ft 4.410 k 75.997 k 0.0 th 2.248 k-ft +D+0.60W+H 0.0580 PASS 0.0 ft 4.410 k 75.997 k 0.0 2.248 k-ft +D+0:70E+H 0.0580 PASS 0.0 ft 4.410 k 75.997 k 0.0 dIX 2.248 k-ft +D40.750Lr+0.750L+0.450W+H 0.09533 PASS 0.0 ft 7.248 k 75.997 k 0.0 2.248 k-ft +D+0.750L+0.750S+0.450W+H 0.0580 PASS 0.0 ft 4.410 k 75.997 k 0.0 2.248 k-ft ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title, 7220 S.W.39TH.TERRACE, Engineer: Proiect ID: MIAMI FLORIDA 33155 Project Descr. CA-0005512 ORLANDO M.FORTUN RE.22249 SP.INSP.369P dp i near a Z ssPrt Masonry Column File c:lUsers\ORLAND-100CUME-11E 104F9 ENERCALC,INC.1983.2014,Buil; 26,Ver.6.14.t.26 Description: 14-016-029 BLOCK COLUMN 12 X 12 Load Combination Results .. Maximum Bending Stress Ratios Maximum Axial Load Maxim im me Load Combination Stress Ratio,Status Location —Actual.--- Allow Actual Allow +D+0.750L+0.750S+0.5250E+H 0.0580 PASS 0.0 ft 4.410 k 75.997 k 0.0d 2.248 k-ft +0.600+0.60W+0.60H 0.03480 PASS 0.0 ft 2.646 k 75.997 k 0. 2.248 k-ft +0.600+0.70E+0.60H 0.03480 PASS 0.0 ft 2.646 k 75.997 k 0. 2.248 k-ft _Maximum Reactions Unfactored Note: Only nonzero moi ns are listed. Y-Y Axis Reaction Axial Reaction Load Combination @ Base @ Top @ Base D Only k----- k — --- 4 ----- -- - Lr Only k k 3.784 k a D+Lr.. k k 8.194 k Maximum Deflections for Load Combinations-Unfactored Loads Load Combination Max.Y-Y Deflection Distance DOnty -- - -------- 0.0000 in-------O.00O ft -- —UO TO -- �� ---N --- --- Lr Only 0.0000 in 0.000 ft D+Lr 0.0000 in 0.000 ft Cross Section Interaction.Diagram _ F = � 0% Masonry Column P-M Interaction Diagram -- - — 72.3-1 Allowable Moment(k-ft) Pa-Allowable=72.33 m ! i 65.1 .I �-- i_ • • 57.9 Q a- 50.6 Mn.Ea=o.lo-Depth 0 LL { • • Comps W zone n Z v1 � I - Bar sue_X5.0.. I I ., '. V ♦H�� IL r - _ 36.2-1 I W CL ! Balanced Pb,Mb=(31 ` �ilw 9 28.9- - - lCJUA — F � 21.7 o 14.5 7.2._� - - .•.•.•a i. r - w1PU=0=917 . • g T --v r----r4-----z 1---- 29 xs -- �3 -- y>c• -5:r- 6�'- — r•••• •• r Q W V Q CL Olt W H ORLANDO M.FORTUN,CONS.ENGS.P.A. Project Title: 7220 S.W.39TH.TBRRACE, Engineer: Project ID: MIAMI FLORIDA 33955 Project Descr CA-0005512 ORLANDO M.FORTUN N P.E.22249 SP.INSP 369Pr o, MAY 2 14.344PM General FootingFile=c:\Users\ORLAND-11DOCUME 11E4114F9F ENERCALC,INC.19832014,Buil 6,Ver 6.14.1:26 Description: 14-016-029 FOUNDATION FOR COLUMN C-1 Code References -- -� Calculations perAC1 318-11, IBC 2012, CBC 2013,ASCE 7-10 Load Combinations Used :ASCE 7-10 General Information LL Material: Properties Soil Design Values 0 f c:Concrete 2B day strength 3.0 ksi Allowable Soil Bearing = ksf fy:Rebar Yield = 60.0 ksi Increase Bearing By Footing Weight = Ec:Concrete Elastic Modulus = 3,122.0 ksi Soil Passive Resistance(for Sliding) = pcf Concrete Density = 145.0 pcf Soil/Concrete Friction Coeff. _ cp Values F4exure _ 0.90 Shear 0.750 Increases based on footing Depth Analysis Settings Footing base depth below soil surface = 4( ft Mn Steel /o Bending Reinf. = Allowableressure increase r foot of de tl= ksf Min Allow%Temp Reinf. = 0.00180 when footing base is below p = ft Min.Overturning Safety Factor = 1.0 :1 Mm.Sliding Safety Factor = 1.0 :1 Increases based on footing plan dimension Add Ftg Wt for Soil Pressure Yes Allowable pressure increase per foot of dept= N ksf Use ftg wt for stability,moments&shears Yes when maximum length or width is greater4 It Add Pedestal Wt for Soil Pressure No H Use Pedestal wt for stability,mom&shear No U) Dimensions Width parallel to X-X Axis - 3.0 It Z 3 Length parallel to Z-Z Axis = 3.0 ft Z a Footing Thicknes 12.0 in4D;-- ---- a T I Q CC , Q O0 LL Pedestal dimensions... X Z pZ:parallel to X-X Axis _ 12.0 in p :parallel to Z-Z Axis 12.0 in �D .� n Height in C i m ac Rebar Centerline to Edge of Concrete.. W g u W at Bottom of footing = 3.0 in fD = °- a Reinforcing—-- -- --- _—:- �� 3 r °Q..... Bars parallel to X-X Axis .. • ,y Number of Bars = 4.0 ...... '. • Reinforcing Bar Size = # 5 • CL . Bars parallel to Z-ZAxis .... .. Number of Bars = 4 071 -- --- —� : T - . Reinforcing Bar Sb # 6 ` T 4-+5 Bars - ! ��;.. Bandwidth Distribution Check (ACI 15.4.4.2) — —C X-Xs�r�-,-z-- ••••••r-rim-„ � �• Direction Requiring Closer Separation n/a • , • . Z. .•.... #Bars required wittrin zone n/a •• • - #Bars required on each side of zone n/a Applied Loads - --D Lr -----L---- - S W E H ------ P:Column Load = 4.410 - --.7$4 - -- -- Q k OB:Overburden = W ksf M-xx = FROM tj k-ft M-ZZ = ts*L DL k ft V-x � U W k V-z = I- k