Loading...
ELC-15-889 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-232605 Permit Number: ELC-4-15-889 Scheduled Inspection Date: August 19, 2015 Permit Type: Electrical - Commercial Inspector: Devaney, Michael Inspection Type: Final Owner: Work Classification: Addition/Alteration Job Address: 1700 NE 105 Street Miami Shores, FIL Phone Number Parcel Number 1122300500001 Project: <NONE> Contractor: BASS UNITED FIRE &SECURITY SYSTEMS INC Phone: (954)785-7800 Building Department Comments IP AND CELL RADIO INSTALLATION Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 19, 2015 For Inspections please call: (305)762-4949 Page 2 of 39 �sµOL�t Miami Shores Village �' PermftType Eleatrioai Com�nr �it:, •' 10050 N.E.2nd Avenue NE �iti teratton .... . . ' Miami Shores, FL 33138-0000 Phone: (305)795 2204 F�ORtD4' lir 311 Expiration: 11/0912015 -T . R•..1.:n 3�.�• Project Address Parcel Number Applicant 1700 NE 105 Street 1122300500001 Miami Shores, FL Block: Lot: SHORES CONDO INC Owner Information AddressPhone Cell LSHORES CONDO INC 1700 NE 105 Street MIAMI FL 33138-2139 Contractor(s) Phone Cell Phone Valuation: $ 800.00 BASS UNITED FIRE 8r SECURITY SYS (954)785-7800 Total S Feet: 4 0 Type of Work:IP AND CELL RADIO INSTALLATION Available Inspections: Additional Info: Inspection Type: Classification:Residential Final Scanning:3 Meter Box Alteration Relocation Fire Alarm Service Change Review Electrical Review Electrical W.W. Underground Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $0.60 DBPR Fee Invoice# ELC-4-15-55212 $2.25 05/18/2015 Check#:20454 $ 109.10 $50.00 DCA Fee $2.25 Education Surcharge $0.20 04/16/2015 Check#:20427 $50.00 $0.00 Permit Fee $150.00 Scanning Fee $3.00 Technology Fee $0.80 Total: $159.10 ca LJ C.J .Gs In consid tion of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertainingereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting tais permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required fQPELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS, ROOFING and SWIMMING POOL work. �n OWN ERSI3AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructig?and zoni Futhermore, I authorize the above-named contractor to do the work stated. May 18, 2015 Auth i d Sign ure:Owner / Applicant / Contractor / Agent Date Builddng Department Copy May 1015 1 0 Miami Shores Village : z Building Department APR16 N15 � �� 1 g 5 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 r'1 c Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 l C, BUILDING Master Permit No. f I PERMIT APPLICATION Sub Permit No. ❑BUILDING ffi� ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 1700 NE 105 ST City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-2230-050-0010 Is the Building Historically Designated:Yes NO Occupancy Type: CONDO Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name(Fee Simple Titleholder):THE SHORES CONDO, INC Phone#:305-893-6741 Address: 1700 NE 105 ST 4= City: MIAMI SHORES State: FLORIDA Zip: 33138 Tenant/Lessee Name: Phone#: Email: CES600@YAHOO.COM CONTRACTOR:Company Name: BASS UNITED FIRE & SECURITY SYSTEM, INC. Phone#: 954-785-7800 Address: 3000 GATEWAY DR City: POMPANO BEACH State: FLORIDA Zip: 33069 Qualifier Name: BRAD HIGDON Phone#: 954-816-7230 State Certification or Registration M EF0000084 Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: :p Value of Work for this Permit:$800.00 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑■ New ❑ Repair/Replace ❑ Demolition Description of Work: IP AND CELL RADIO INSTALLATION Specify color of color thru tile: Submittal Fee$ Permit Fee$ 1V'_0 je7 G' CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ Q TOTAL FEE NOW DUE$ 1 (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature �^ ��t Signature OWNER or AGENT CONTRA OR The foregoing instrument was acknowledged before me this The foregoing i rument was nowledged before me this (i day C of m fAa,(?�"� 120/.5 by /1 � day of t 20 r 5 by l /1ClKICS l9 kAW c/� who is personally known to /)Lh�> (7 D6 Al who is personally known to me as me or who hac nrnd",04 as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: (� Sig t� e" 6 n: �.1.(,'�F4i Sig Print: A Print: l i ct/�€'i- i c'i ,Lt pY` PATRICIA A.STUBBS ANDREA SHEAHAN Seal: :==o`` "a� . Seal: ` € MY COMMISSION#EE885191 NOTARY PUBLIC EXPIRES March 18,2017 a 9 ;TRATE OF FLORIDA �. W Of "°'�. 4umm#EE151907 7 -0t 3 FloridallofaryService.com APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Detail by Entity Name Page 1 of 3 FLORIDA I)FI)ARTMENT OF STATE Detail by Entity Name Florida Non Profit Corporation THE SHORES CONDOMINIUM, INC. Filing Information Document Number 707621 FEI/EIN Number 591095398 Date Filed 07/21/1964 State FL Status ACTIVE Last Event AMENDMENT Event Date Filed 06/27/2012 Event Effective Date NONE Principal Address 1700 NORTHEAST 105TH STREET MIAMI, FL 33138 Changed: 04/22/2000 Mailing Address 1700 NORTHEAST 105TH STREET MIAMI, FL 33138 Changed: 04/22/2000 Registered Agent Name &Address JARA &ASSOCIATES, PA 19 W. Flagler St. Suite 504 MIAMI, FL 33130 Name Changed: 01/27/2012 Address Changed: 01/25/2015 Officer/Director Detail Name &Address Title Treasurer STUBBS, PATRICIA http://search.sunbiz.org/Inquiry/CorporationSearch/SearchResultDetail?inquirytype=Entity... 4/10/2015 a 0 RICK SCOTT, GOVERNOR KEN LAWSpN SECRETARY STATE OF FLORIDA M DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ELECT RLCAL CONTRACTORS LICENSING BOARD a EF0000084 ` The ALARM SYSTEM CONTRACTOR I Named below IS CERTIFIED Under the provisions of Chapter 489 FS: n Expiration date:_AUGID 31;20:16 o R HtGDON, BRAD A LL BASS-UNITED FIRE& SG1RlTY SYSTEMSt;;tNC 370.SE 5TH TERR POMPANO BEACH 33060 N 1� O) OD V F ISSUED: 08/03/2014 DISPLAY AS REQUIRED BY LAW` . SEQ# L1408030004343 n v 0 0 n m �n x LL 0 O O u 0 m r u E 0 LL ggg ON RAM? s _ 115 S. Andrews Avg;, R -1 A QQ: Ft. Lauderdale, FL 33 i?�-'f X54 .1, 4000. 0 VALID OCTOOM 1, � � THRatlGH SEPTEMBER �O� p15 Receipt#;181-2'752 Business:Name,BASS UNITED F I & SECURITYBus ELECTR L/ALAJRM8/Ct3NTRA&0R t •H 1. SYISTPooIne BM CONTR 1. N Owner Name. BRAD HXCI)oN 1 BusinessR O ►en.+ #:t o 03./2005 Business.Location 3,P 0,0 GATEWAY; D StatefCaunt rlCertlReg: 0 00 0 O s 4 Exemption BEACH �a�e: � Business Phone:has-7 800 a Re�o.�» seatsrnp�aye�rs 14ls12 chenes i�rcrf �stctnais' r��r U$�ding Bu��t�ss Only Number:of chines Vend TYlae Tax Amount Transfer Fee NSF F+a� P�nai� Priot Years �oilecban Cyst Tata maid 00" t E} CI l3os D (1.G ; 27. # X .: CO M THIS RECEIPT MUST BE POSTED C NSPICUOUSLY IN YOUR PLACE OF BUSINESS 0 THIS BECOMES A TAX REGEII�7 This tax Is levied for the privilege of doing business within Broward'County and is moll.retgulatoryr in nature. You must meet all County an Jlunicipaiity planning WHEN VALIDATED and zoning requirements. This Business.Tax Receipt must be transfarred kvhe'i th4 business is sold, business name has changed or o have mooed the business lotion, This receipt des not indicate that the business is legal or that r ii is in compliance with Stato or loci laws and regulatiins Mailing Address: Ems} HICDON " 3 UC GATEWAY DR Paid 08/28'/201.4 27.40 POMPANO BEACH, FL 33069 0 o m U LL 2014 AUi AC40 CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/Y 4/14/20155 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: Sharon R. Myers, AAI, CRIS Frank H. Furman, Inc. pHoNE (954)943-5050 FAC, C N (954)942-6310 1314 East Atlantic Blvd. EMAIL .sharonm@furmaninsurance.com P. 0. BOX 1927 INSURERS AFFORDING COVERAGE NAIC# Pompano Beach FL 33061 INSURER A-Greenwich Insurance Co 22322 INSURED INSURERS De ositors Insurance Company 42587 Bass United Fire & Security Systems, Inc INSURER C: Bass United Fire Sprinklers INSURER D: 3000 Gateway Drive INSURER E: Pom ano Beach FL 33069 INSURER F: COVERAGES CERTIFICATE NUMBER:2014 Masterw/o end# REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUBR POLICY EFF POLICY EXP LTR POLICY NUMBER MM/DD/YYYY MM/DD LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE To RENTED PREMISES Ea occurrence $ 50,000 A CLAIMS-MADE a OCCUR G6400458 /21/2014 /21/2015 MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,000,000 POLICY X PRO LOC $ AUTOMOBILE LIABILITY Ea aBINFDt SINGLE LIMIT 1 000 000 B X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED CP3006692715 /15/2014 6/15/2015 BODILY INJURY(Per accident) $ AUTOS AUTOS HIRED AUTOS NON-OWNED PROPERTY DAMAGE $ AUTOS Per accident Florida PIP Basic $ 10,000 UMBRELLA LIAB HOCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED RETENTION$ $ WORKERS COMPENSATION WC STATU- OTH- AND EMPLOYERS'LIABILITY Y I N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? F N/A (Mandatory in NH) E.L.DISEASE-EA EMPLOYE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,if more space is required) Electrical Contractor CERTIFICATE HOLDER CANCELLATION 13057568972@efaxsend.com SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN City of Miami Shores ACCORDANCE WITH THE POLICY PROVISIONS. Building Department 10050 NE 2 Ave AUTHORIZED REPRESENTATIVE MiamiShoresVillage, FL 33138 Dirk DeJong/SR ACORD 25(2010/05) ©1988-2010 ACORD CORPORATION. All rights reserved. INSMS rani nns�m TI,.Annon --A Inn-nro—icf—A—t—of AL`non AC�D� 044/15/1/15/1CERTIFICATE OF LIABILITY INSURANCE DATE IYYYY) 5 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT:If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed.If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement.A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Aon Risk Services,Inc of Florida NAME: Aon Risk Services,Inc Of Florida 1001 Brickell Bay Drive,Suite#1100 PHON /C FAX Miami,FL 33131-4937 ANo Ext:800-743-8130 A/C, /C No):800-522-7514 EMAIL ADDRESS: ADP.COI.Center Aon.com INSURERS)AFFORDING COVERAGE NAIC# INSURER A: Illinois National Insurance Co 23817 INSURED ADP TotalSource FL XI,Inc. INSURER B 10200 Sunset Drive INSURER C: Miami,FL 33173 ALTERNATE EMPLOYER INSURER D: Bass-United Fire&Security Systems,Inc. INSURER E 1480 SW 3rd St Suite C-9 Pompano Beach,FL 33069 INSURER F: COVERAGES CERTIFICATE NUMBER:833618 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LIMITS SHO\NN ARE AS REQUESTED. INSR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF POLICY EXP LIMITS LTR INSR WVD MM/DD MM/DDI COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGE CLAIMS-MADE F—] OCCUR PREM SESOEaENTED occurrrence $ MED EXP(Any oneperson) $ PERSONAL&ADV INJURY $ GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ POLICY E]PROJECT 71 LOC PRODUCTS-COMP/OP AGG $ OTHER $ ACOMBINED SINGLE LIMIT AUTOMOBILE LIABILITY Ea accident $ ANY AUTO BODILY INJURY Perperson) $ ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY Per accident $ NON-OWNED PROPERTY DAMAGE HIRED AUTOS AUTOS Per accident $ UMBRELLA LIABOCCUR EACH OCCURRENCE $ EXCESS LIAR H CLAIMS-MADE AGGREGATE $ DEC I I RETENTION$ WORKERS COMPENSATIONX PER OTH- A AND EMPLOYERS'LIABILITY Y/N WC 094179802 FL 07/01/14 07/01/15 STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N/A E.L.EACH ACCIDENT $ 2,000,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ 2,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 2,000,000 I TJ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached if more space is required) All worksite employees working for BASS-UNITED FIRE&SECURITY SYSTEMS,INC.,paid under ADP TOTALSOURCE,INC.'s payroll,are covered under the above stated policy. BASS-UNITED FIRE& SECURITY SYSTEMS,INC.is an alternate employer under this policy. RE:Electrical Contractor CERTIFICATE HOLDER CANCELLATION Miami Shores Village SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Building Dept THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 10050 NE 2 Ave ACCORDANCE WITH THE POLICY PROVISIONS. Miami Shores,FL 33138 AUTHORIZED REPRESENTATIVE } �`���__tt__� (tilt LSA(Jtt'iCVZ=,&, SILC &td� ©1988-2014 ACORD CORPORATION.All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Miami Shores Village Building Department �ORIDp 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 RECEIPT PERMIT#: L� DATE: ZC� o Contractor (NAME) o Owner o Architect Picked 2 sets of ns and (other) � l 2-a Address: From the building department on this date in order to have corrections done to plans And/or get County stamps. I understand that the plans need to be brought back to Miami Shores Village Building Dept to continue permitting process. Acknowledged by: (Signature) PERMIT CLEWNITIAL: RESUBMITTED DATE: 4 i S PERMIT CLERK INITIAL: E SCOPE OF WORK /j WC Ci�� N\t'1 (N/ BASS UNITED FIRE AND SECURITY WILL FURNISH AND INSTALL IPGSM-4G IP INTERNET&GSM 4G/3G/2G)DUAL PATH JA — CHANICAL COMMUNICATOR IN AN EXISTING BUILDING WITH AN EXISTING FIRE OM I ALARM SYSTEM.THE IP INTERNET&GSM COMMUNICATOR WILL BE EDROOM '%�' INSTALLED NEXT TO EXISTING FACP AND WITHIN 20 FEET OF THE FIRE D / ®ETF PANEI > ,�E DEVICE LEGEND 4N �,cooxn -- / %i\ BEDROOM /.--' - 72; 7�101 CITY DESCRIPTION TRASH Z3.07 ROOM _. r E EXISTING SILENT KNIGHT SK-5207 FIRE ALARM CONTROL ELEV� �y� . t., ,.� -` � PANEL Y, NEW HONEYWELL IPGSM-4G IP INTERNET&GSA (4G/3G/2G) DUAL PATH FIRE ALARM COMMUNICATOR -- I SCOPE OF WORK _ 1�1 E tv � ' P � 5/7scd CORRIDOR o LOBBY "' AREA OF WORK I E ,,> 1 I a \ E !/ELEV.2 % MAIL ELECT. ROOM ROOM E i 1, I BED Z3,05wc QE � � �i Ili ••• \: r OFFICE - LAUNDRY - ••' > „_'\l'' OFFICE 41 ..: /, �✓/ �. i 15/7 WC ,.� �� // 1 ST FL 1CAL ROOM ' SCALE:NTS r PROJECT: THE SHORES CONDOMINIUM - - r a4 CERT.No.97377 y % UNITED LEVEL IV ADDRESS: , FIRE&SECURITY SYSTEMS,INC. N I C T 1700 NE 105TH STREET '•rte 3000 GATEWAY DRIVE TOLL FREE=>1.800.372.2770 POMPANO BCH,FL 33089 24 Hour Emergency Service FAX=>x•785 7804 MIAMI SHORES, FL 33138 RZ r� 777 State Licl EF 0000084 954.785.7800 www.bassunked.com PLANS REVIEW BY: BRAD HIGDON " wNr how eATreRn &MEMNON" LED DISPLAY �o0 00 ® ®o0E3 � MpOTROt•LE POWER BOOST 1 ECPDIALER CAPTURE MODULE 0 TELCO 1 C3 p I� K NOQ ° O BABBB TO FIRE PANEL MAIN DIALER U TELCO 2 0 °PN o 4"°s 0 = TO FIRE PANEL BACKUP DIALER _ o o Ac oN ya —T . —AC(TRANSFORMER) --><AC(TRANSFORMER) � --EARTH GROUND(CATNET) { /l I GNDMUO Tx/01" m(mll ❑ zOUTPUT,(10.11.0 z COMMUNICATOR oU1P�T o�T,0C Im Z 0 a ��= 0 o ❑ 7110 Om R oO❑ ACON WTPUn(OUT-). PRO PORT o .... LSid" $A�j�J p O •••• 6666• � • •• • 6666 • �•••� 6666 6666• • L„1„.N m m :066 0 ONO(°Llp v 0 0• :606:6 ECP IN MHi) 3111 D LLJJ 0 yr•••N• •6•• 00090 • • • • • Cl) • • •• • •69•• FLTOLRMO) It • V® • • • • •6.09• TO ROUTER X00 • •6• i6••• 1 WI RING DIAGRAM SCALE: NTS PROJECT: --------------- THE --- THE SHORES CONDOMINIUMCERT.No.97377 ,a��� /Sys UNITED LEVEL IV ADDRESS: FIRE 8 SECURITY SYSTEMS,INC. NIC T 1700 NE 105TH STREET 3000 GATEWAY DRIVE TOLL FREE_>1.800.372.2770 POMPANO BCH,FL 33065 24 Hour Emergency Service FAX=>954.785.7804 MIAMI SHORES, FL 33138 State Lic.#EF 0000084 954.785.7800 www.bassunded.com PLANS REVIEW BY: BRAD HIGDON . ... . . ... . % .. . . . % .. . • ••• •RQ�eywle IPGSM-4G .: :•• . . . . . .. . . .. IP Internet & QSM ••• • (40/3W20) Dual Path Communicator General • The IPGSM-4G is a 4G fire alarm communicator that offers ..• : •.• : : .. contact ID reporting with any Fire Alarm Control Panel(FRCP) that has a built-in dialer.This easy to install,dual path commu- nicator connects directly to the primary and secondary com- munication ports of a Fire panel's Digital Alarm Communicator Transmitter (DACT). It offers three selectable reporting paths which include: (Cellular only), (IP only),or(IP primary/cellular backup). In the event of an off-normal condition,the fire panel sends contact ID formatted information to the IPGSM-4G com- municator panel. The IPGSM-4G then reformats the data into highly encrypted Ethernet packets for transmission to the Alarm-Net receiver via customer-provided Internet/Intranet connection or the GSM network. • Reliable connection: IP and GSM connection tested every Alternative communication methods are critical in the market- day. place due to Vo1P(Voice over IP),migration from POTS(Plain . QOS: Quality of Service diagnostics via AlarmNet conveys Old Telephone Service) and growth of digital radio networks. vital communicator information including when message The IPGSM-4G's exclusive dual-path communications solution was received,signal strength,and message path used. combines Internet service with GSM for added reliability and . 7720P Hand-held programmer for easy setup. an extra level of security.All signals from the IPGSM-4G com- municator panel are delivered to Honeywell's AlarmNet Net- work Control Center, which routes the information to the Operation appropriate central station.The state of the art AlarmNet net- When an event occurs, the Fire Alarm Control Panel goes off work control center is fully redundant and monitored 24/7. hook to dial the central station.The IPGSM-4G Dialer Capture AlarmNet has the ability to route messages using AlarmNet-i Module detects the off-hook condition and provides the fire and 800 PLUS services, providing true redundancy and multi- panel with a dial tone. When the fire panel detects the dial path message delivery. tone, it begins dialing the central station. After the dialing is The IPGSM-4G is designed to operate over the most common completed,the Dialer Capture Module returns a handshake to GSM networks including 2G,3G and 4G. Its multi-GSM plat- the fire panel.The fire panel then sends the contact ID reports form technology automatically chooses the best available cel- to the Dialer Capture Module, which in turn sends a kiss-off lular signal in the area based on signal strength and after the report is successfully received from the fire panel. seamlessly self-adjusts to maintain critical life safety communi- The Dialer Capture Module sends the contact ID reports to the cation. IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- FeatureS tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent • Saves the cost of two dedicated phone lines. on configuration). • Dual path communications. Can communicate to central station using Internet or cellular technology. EASY to Program • Requires no change to the existing Fire Alarm Control The IPGSM-4G communicator can be pre-programmed using Panel configuration. The IPGSM-4G connects directly to the 7720P programmer to enter all central-station information. the primary and secondary telephone ports. This is saved to the IPGSM-4G communicator panel memory. • Multi-GSM platform compatibility for 2G,3G and 4G. When the IPGSM-4G communicator is installed at the site and • Operates over the following communication protocols: connected to the Internet/Intranet, it registers itself with the HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) AlarmNet receiver. GPRS(2G). For most installations,the only required parameters are: • Works over any type of customer provided Ethernet 10/100 . Primary City ID (two digits) obtained from your monitoring • Base network connection (LAN or WAN), DSL modem or station. cable modem. • Primary Central Station ID (two digits) obtained from your • Data transmits over standard contact-ID protocol but is monitoring station. secured with the industry's advanced encryption standard . Primary Subscriber ID(four digits)obtained from your mon- (AES 256 bit). itoring station. • Supports both dynamic(DHCP)or Public and Private Static . Communication Module's MAC ID, and MAC CRC number IP addressing. located on outside of box,and inside of the module. • Built-In Power Supply module: On board charging circuit All of these parameters are assigned by the monitoring station. design accommodates back-up battery. Includes primary power and battery supervision. NOTE: Some assembly is required. See Installation and Setup • Diagnostic LEDs:Signal strength and status indicators. Guide#800-12454 for full details. . ... . . ... % .. % .. Panel Capabilities Cabinei Speci cairans ; •;• The IPGSM-4G is compatible with fire panels that use the Dimensions:14.875'H x 12.75'W x 3.0'D(37.8 cm H x 32.4 Contact ID communications format as described in the SIA cm W x 7.6 cm D). DC-05 standard. Color:F:�Al . . . . . . .. . . .. . . ... . . . . . AlarmNet Shippipfg Speciflcatibns.% Honeywell's AlarmNet has been the nationwide leader in Weight:5.3 lbs.(6.94 kg). alarm communications technology since 1986.A reliable alter- Dimenslons�15.g2�' H•x 11.19'VI•j 9.2.5, D (39.7 cm H x native for the transmission of alarm signals,our radio network 34.9 cm W k 333 9�DI • • • • • provides extensive coverage in the United States and Canada. • ••• • • •• • AlarmNet Network Control center processes signals from pow- Tem erefuie:and Nurtidit erful servers in multiple locations equipped with 24/7 infra- p y an g@S structure support.The AlarmNet network consist of redundant This system meets NFPA requirements for operation at 0 - hardware servers,hot back-up databases and generators with 49°C/32-120oF and at a relative humidity 93%*2%RH(non battery back-up at all locations to ensure continuity of service. condensing at 320C t 2°C (90°F t 30F). However, the useful Signals from Alarm-Net are transmitted to the central station's life of the system's standby batteries and the electronic com- receivers using multiple communications paths consisting of ponents may be adversely affected by extreme temperature the Internet, radio network or toll-free POTS service. ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with Installation Requirements a normal room temperature of 15-27°C/60-80°F. UL COMPUANCE Product Line Information To meet UL864MFPA,ensure the following: IPGSM-4G:Internet and Digital Cellular Fire Alarm Communi- s IPGSM-4G must be installed in accordance with NFFA Gator Panel. Includes red cabinet with ademco key and lodc, (National Fire Protection Association)standards 70 and 72. wall outlet box,Dialer Capture Module,iGSM Communications • IPGSM-4G must be mounted in the same room and within Module, antenna & mounting adapter, PowerBoostl power 20 feet of the fire panel. supply, LED display board, tmnsforrner, manual, & required • IPGSM-4G, and all equipment used for the IP connection screws,cables,etc. (such as the router,hub,modem,etc.)shall be listed,must GSM-ANT3DB:3db gain external/remote antenna. be powered from an un-switched branch circuit,and be pro- 7626-501­11C:50 ft.antenna cable,low loss. vided with appropriate standby power. 7626-25HC:25 ft.antenna cable,low loss. • IPGSM-4G must use the 7AH battery(not supplied)to pro- WA7626-CA:SNA to N Adapter. vide 24-hour backup capability. 772OP:IPGSM-4G hand held programmer. Electrical Specifications HPTCOVER:Plug in transformer box for IPGSM communicator. BAT-1270:Battery 12 Volts,7 AH,sealed. Transformer: —Primary 120VAC,60Hz,0.5A. Agency Listings and Approvals —Secondary: 18VDC,50VA. The listings and approvals below apply to the basic IPGSM-4G Battery: communicator panel.In some cases,certain modules may not be —One 12 V 7.0 AH lead-acid battery(not supplied). listed by certain approval agencies,or listing may be in process. —Battery charging current: 1 Amp maximum. Consult factory for latest listing status. —Battery discharge current: Standby 230mA, Active UL Listed:S789. 950mA. CSFM:7300-1645:0199. FDNY:COA#6150. This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford,CT 06472-1610 hpp_techserv@honeywell.com www.honeywellpower.com DH-60769:B June 2013 Made in the U.S.A. ' ®U.S.Registered Trademvark V ®2013 Honeywell Internet-.,-...,- SRElBIMtSEYS�ECtIi� Page 2of2 ir11tEliT SYSTEMS . ... . . . ... % .. . % .. a . . CERTIFICATE OF C6M: P'LI'ANC�E .. . a.. Certificate Number 20130430-S789 : : :.: • : ' : ". Report Reference S789-20101001 0-. •:• •• Issue Date 2012-APRIL-30 .. . . . .. .aa .. . . a . . a a a . . a Issued to: HONEYWELL SECURITY . . . ' "' " SUITE 100 2 CORPORATE CENTER DR PO BOX 9040 MELVILLE NY 11747 This is to certify that CONTROL UNIT ACCESSORIES, SYSTEM; CENTRAL representative samples of STATION ALARM UNITS; LOCAL ALARM UNITS; POLICE-STATION-CONNECTED ALARM UNITS; PROPRIETARY ALARM UNITS Fire Alarm Equipment: Internet and Digital Cellular Fire Communicator: Models iPGSM-COM, iPGSM-DP, iPGSM-4G Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s)for Safety: UL864, Control Units and Accessories for Fire Alarm Systems Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Listing Mark should be considered as being covered by UL's Listing and Follow-Up Service. The UL Listing Mark generally includes the following elements:the symbol UL in a circle:®with the word"LISTED"; a control number(may be alphanumeric)assigned by UL; and the product category name(product identifier)as indicated in the appropriate UL Directory. Look for the UL Listing Mark on the product. This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. 4" f04�r William R.Camey,Director,North American CertftsWn programa V UL LLC Any Information and documentation Involving UL Mark servbes are provided on behalf of UL LLC(UL)or any authorind licensee of UL For questions,please contact a local UL Customer Service Representative at vrww.ul.comlcontactus Page 1 of 1 . ... . . ... % .. . % .. Honeywell loll Honeywell Power ' IPGSM-4G Description: •• • • •• ••• •• The IPGSM-4G is a secure and reliable Commercial FirdAWIn:CbrWuIhIcatar that offers Contact-ID reporting for any Fire Alarm Control PE";e;(l:A•C1' that tms S built-in dialer. This single path (cellular only or IP only) or dual path (IP primary & cellular backup) communicator eliminates the need for costly plain old telephone lines (POTS) and replaces them with state-of-the-art cellular or internet/ IP communications. The IPGSM-4G gives you the power to abandon your old POTS lines and upgrade to a more versatile and cost effective solution for monitoring your fire alarm system while ultimately adding more value to your business. IPGSM-4G Benefits: ✓ Reduce unnecessary service calls from maintenance communication troubles or intermittent network outages by using the 60 minute NFPA 2013 supervision feature. ✓ Eliminates the significant monthly cost of two dedicated phone lines as well as all the problems that arise when using existing legacy POTS lines. ✓ Convert any Fire alarm control panel that uses Contact ID and has a dialer to IP or GSM communications. ✓ Easy to install and configure with existing Fire panel resulting in faster installation times and maximum return on investment. ✓ Designed for backward compatibility and product longevity by accommodating existing 2G platforms while also working on newer networks such as 3G or 4G. For more information go to http://www.honeywelipower.com and download the IPGSM- 4G datasheet DH-60769. Sincerely, Ken Gentile Product Manager . . ... . . . ... Honeywell Product Honeywell Power Announcoment IPGSM-4G Commercial Fire Oommunicator 0 0 Now Compliant with NFPA 72 2013 Superyisfivp 0 wrements! 0 0 see 00 May 01, 2014 Document#HPP-042914 Dear Valued Customer, Honeywell Power is excited to announce that the IPGSM-4G ------„__„ Commercial Fire Alarm Communicator is now compliant with NFPA 72 2013 requirements for sixty minute supervision. -w- Reducing the amount of service calls due to maintenance communication troubles is a key benefit of using the IPGSM-4G as a sole path solution for commercial fire monitoring. In the past, some of the most common trouble occurrences would result from cellular tower maintenance that would only last minutes and automatically clear by the time a service technician arrived on site. Supervising at longer intervals will help reduce these trouble conditions and minimize unnecessary and costly visits to customer sites. The sixty minute supervision feature will also help reduce service calls from trouble conditions that occur when the IPGSM-4G is configured to communicate over IP only and is experiencing momentary network outages. For jurisdictions that have adopted the NFPA 72 2013, the IPGSM-4G meets Chapter 26 section 26.6.3.1.5 requirements for a Single Communications Path when configured for IP only or cellular only. For jurisdictions that have adopted 2013 and require a dual path solution for maximum survivability; the IPGSM-4G meets, Chapter 26 section 26.6.3.1.6 for Multiple Communication Paths supervision requirements when configured as 1P primary and cellular backup. Below you will the field selectable communication paths settings on the IPGSM-4G that can meet either the NFPA 72 2010 requirements or the NFPA 72 2013 requirements. Selectable Path Description Supervision Times 2010 GSM Single path cellular only) 5 minutes 2010 IP Single path IP only) 5 minutes 2010 IP & GSM Dual path IP primary and cellular backup) 24 hours 2013 GSM Single path cellular only) 1 hour 2013 IP Single path IP only) 1 hour 2013 IP & GSM Dual path IP primary and cellular backup) 6 hours ... . . . ... . . % .. . . .. . . .. . . . . . . . . . . . ... . . . ... . ... . . .. ... .. . . . .. . .. . . . . ... . .. ... . . . . . .. CUE pro n s No: 1 i .fit'.� A 0000794302