Loading...
FW-14-2456 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-241493 Permit Number: FW-11-14-2456 Scheduled Inspection Date: August 18, 2015 Permit Type: Fence/Wall Inspector: Rodriguez, Jorge Inspection Type: Final Owner: RODIER,ALEXANDRE & EMILIE Work Classification: Iron/Ornamental Job Address: 1009 NE 104 Street Miami Shores, FL 33138-2655 Phone Number Parcel Number 1122320290140 Project: <NONE> Contractor: HOME OWNER Building Department Comments FRONT GATE SLIDING AND FENCE Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-223045. Missing section of fence on the east side. Failed Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 17, 2015 For Inspections please call: (305)762-4949 Page 24 of 38 Miami Shores Village I� Building Department NOV 0 7 2014 z� 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 ���r �-��_•,• `.- �� J Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(30S)762-4949 FBC 20 �,Ul' I LD I NG Master Permit No. PERMIT APPLICATION Sub Permit No. BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION [:]RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP /- CONTRACTOR DRAWINGS JOB ADDRESS:`O g e e 04 S` �l 2 City: Miami Shores County: Miami Dade Zip: J J Folio/Parcel#: Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFFFFE-:z OWNER: NameTitleholder Simple Fee ( p )l �x��� 1`ODi � Phone#: Address: ^^ 117 2 6 N 6 /(6 S City: P 1 0_1 S k6 Q-69 State: IT-L Zip: �3 i 3 s Tenant/Lessee(�Naamp Name- Phone#: 6 ,� ( 6 Email: A ' VWOLUV1.l. 2 t2 QAAK"L` (.C>U-k CONTRACTOR:Company Name: 0 _y —Phone#: Address: City: State: Zip: Qualifier Name: Phone#: State Certification or Registration#: Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit:$ 2,000 Square/Linear Footage of Work:SO Type of Work: ❑ Addition ll❑ Alteration p IR New ❑ Repair/Replace ❑ Demolition Description of Work: If D�Lr CYaE? CeL��� e . ��+•��� ��pp2 vw:�.� Specify color of color thru tile: Submittal Fee$-5Z—) Permit fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ TOTAL FEE NOW DUE$ @ . 20 (Revised02/24/2014) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature - Signature OWNER or AGENT CONTRACTOR Thi fregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this 11 day of ���� 202`t�� , by day of 20 by 7'-"2 VZ o is personally known to who is personally known to me or who has produced K:t -- (Way(�(� as me or who has produced as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: "'" "`%� NOTARY PUBLIC: Sign: , % `' Sign: wo Print: — Print: Seal: ''dx3�O Seal: APPROVED BY Plans Examiner ��JV Zoning Structural Review Clerk (Revised02/24/2014) ,5t!�Ru Miami Shores Village m,,, p,,,?" Building Department 10050 N.E.2nd Avenue NNI've."a Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305)756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME: Ae."awc.-a- 0 O e)l uaz DATE: ADDRESS: t2 g ar 6 SO 01 01 S f C)oz% 33 139 FC Dohereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida,F.S 489.103(7).And I have read and understood the following disclosure statement,which entitles me to work as my own contractor;I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor.You have applied for a permit under an exception to the law.The exemption allows you,as the owner of your property,to act as your own contractor even though you do not have a license.You must supervise the construction yourself.You may build or improve a one-family or two-family residence.You may also build or improve a commercial building at a cost of$25,000.00 or less(The new form states 75,000).The building must be for your own use and occupancy.It may not be built for sale or lease.If you sell or lease a building you have built yourself within one year after the construction is complete,the law will presume that you built for sale or lease,which is a violation of this exemption.You may not hire an unlicensed person as a contractor.It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances.Any person working on your building who is not licensed must work under your supervision and must be employed by you,which means that you must deduct F.I.C.A and with-holdings tax and provide workers'compensation for that employee,all as prescribed by law.Your construction must comply with all applicable laws,ordinances,buildings codes and zoning regulations. Please read and initial each paragraph. 1. 1 understand that state law requires construction to be done by a licensed contractor and have applied for an owner-builder permit under an exemption from the law.The exemption specifies that I,as the owner of the property listed,may act as my own contractor with certain restrictions even though I do not have a license. Initial_ 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial 3. 1 understand that,as an owner builder,I am the responsible party of record on a permit.I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name.I also understand that the contractor is required by law to be licensed in Florida and to list his or license numbers on permits and contracts. Initial_AO 4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding.I may also build or improve a commercial building if the costs do not exceed$75,000.The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete,the law will presume that I built or substantially improved it for sale or lease,which violates the exemption. Initial 5. 1 understand that,as the owner-builder,I must provide direct,onsite supervision of the construction. Initial 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and by county or municipal ordinance. Initial_ r 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner-builder permit that erroneously implies that the property owner is providing his or her own labor and materials. I,as an owner-builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner-builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial AR, 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done.Any person working on my building who is not licensed must work under my direct supervision and must be employed by me,which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act(FICA)and must provide workers compensation for the employee.I understand that my failure to follow these may subject to serious financial risk. Initial IW 9. 1 agree that,as the party legally and financially responsible for this proposed Construction activity,I�will abide by all applicable laws and requirement that govern owner-builders as well as employers.I also understand that the Construction must comply with all applicable laws,ordinances,building codes, and zoning regulations. Initialk_ 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Internal Revenue Service,the United States Small Business Administration,and the Florida Department of Revenues.I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or http://www.myfloridalicense.com/dbpr/pro/cilb/index.html Initial_ 11. 1 am aware of,and consent to;an owner-builder building permit applied for in my name and understands that I am the party legally and financially responsible for the proposed construction activity at the following address: Initial 12. 1 agree to notify Miami Shores Village immediately of any additions,deletions,or changes to any of the information that I have provided on this disclosure. Initial_�T Licensed contractors are regulated by laws designed to protect the public.If you contract with a person who does not have a license,the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court.It is also important for you to understand that,if an unlicensed contractor or employee of an individual or firm is injured while working on your property,you may be held liable for damages.If you obtain an owner-builder permit and wish to hire a licensed contractor,you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued,this disclosure statement must be completed and signed by the property owner and returned to the local permitting agency responsible for issuing the permit.A copy of the property owner's driver license,the notarized signature of the property owner,or other type of verification acceptable to the local permitting agency is required when the permit is issued.et Was acknowledged before me this -7-day of �'L� , 20�� By ��tt-XA--- -'t `�%� ice- who was personally known to me or who has Produced there License or <- l��'--��►r'� a., 6a • 1b,. n SSI' WO) V1 ON _ OWNER NQTAI� sOZ/90l£0 ; i ROLLER POST • •• RECIEVER P T i '� � • • Ll i • • • RO R POST LLE � II .:.••. •• PLAN ®ROLL B,AM &WED GATE CLOSED ••••• • ••• •••••• Ll k i • •••..• of .00. FFE 000*** •.••.• st. Q Xt�&FIVY, A : ., V-TRACK w/FOOTER ELEVATION OF ROLL GATE CLOSED �—RECIEVER POST �—ROLLER POST ' 1-2"X2"FRAME BEHIND PLAN ®ROLL GATE CLOSED _ 2 X2"VERT SUPPORT RELIEVER POST V—WHEELS -+ 4 Ws I? _ + V-TRACK w/FOOTER ELEVATION OF ROLL GATE OPEN n rALD SCALE PROJECT. DRAVN sr. cATt. DATE PROJECT cEcxn en uawNc aaeRlPTmra TITLE asTava nw vm Num" CUSTOMER DWG s MECHANICAL ALUMINUM GATE AT GRADE TOP (NON-STRUCTURAL,DECORATIVE BARRIER,TYPICAL INSTALLATION(GROUND LEVEL ONLY) (HVHZ ONLY) INTERMEDIATE SEE TABLE FOR POST *PICKETS MAY RUN THRU RAIL,TYP. SPACING REQUIREMENTS OR STOP AT INTERMEDIATE PICKET,ATTACH W/ *3%" MAX. 3 RAIL( < 4"OPEP GAP) ¢ (1) #12 SMS AT EACH CONN POINT,TYP. *SELF-CLOSING, SELF-LATCHING EXISTING BARRIER ( LOCKING DEVICE POST/UPF OR FENCE 54" MIN.ABOVE (PER SEPERATE = GRADE(SEE NOTES) ENGINEERING) .. "' *WHEN USED FOR ALUM UHINGELW N*Sf IE�T x POOL APPLICATIONS (2) #14 SMS PER RE NOTE: GATE TO REMAIN IN (2)#12 x Y4SMS CONNECTION TO SECURED POSITION DURING INTO ALUMINUM POSTANDGATEWINDSTORM EVENTS>75MPH POST,TYP. FRAME POST,TYP. SUSTAINED nGATE FRAME, EXISTING BARRIER 3 RAI EXISTING 3 KSI 1TYP. OR FENCE CONCRETE111 7DEEP tttt (PER SEPERATE 1 N.T.S. (VERIFIEDOTHERS) ENGINEERING) 3 / 3 KSI CONCRETE FOOTER � IN WEL COMPACTED SOIL, 3"0 CORE DRILSPACED TO �\ �\ � { n,PEXISTING 3 REJECT / AND 6" MIN. EDGE DISTANCE A 2"SPHERE jf\ W SEE FOOTER NOTE FROM CENTER OF POST TO ANY \ `. •:; J'Y POST FOOTER TABLE(DIA. x DEPTH): CONCRETE FACE FILLED WITH TYP \ i f\/ GATE OPENING GATE ALU"iINUM HIGH STRENGTH,NON-SHRINK, 0 4'-0" 4'-6" 5'-6- G IRON FREE, NON-REACTIVE SEE w 48" 12"x25" 12"x26" 12"x28" rL (4KSI MIN.) GROUT'TYP. FC OTE R TAB = ATTACH H d 60" 12"x28" 15"x27" 18"x ' ASSEll BLYTO a a 72" 18"x27" GATE VVI (2)— 1 SINGLE LEAF SWING GATE NOT APPLICABLE f, #34SJNSPR DROP ROD 1 N.T.S. ELEVATION VIEW NOTE: FOOTERS DESIGNED PER FBC 1819:7 } 3 a INTERMEDIATE ; SEE DOUBLE LEAF TABLE FOR POST RAI-SELF-CLOSING, SPACING REQUIREMENTS 1 rn' c 1/2 ,f SELF-LATCHING EQ. EQ *PICKETS MAY RUN THRU CENTER DR LOCKING DEVICEOR STOP AT INTERMEDIATE - AS 54" MIN. ABOVE RAIL(<_4"_OPEN GAP) m GRADE(SEE NOTES) 11"Ir c PICKET,ATTACH W/ EXISTING 1"SC (1) #12 SMS AT EACH BARRIER OR RECEI ' CONN POINT,TYP. H FENCE 3Kf *SPACED TO REJECT 0 (PER SEPERATE CON loo _ A 4"SPHERE _= ENGINEERING) STRUCTURAL*" x z ALUM HINGE W/ s. '` I a_ STRUCTURAL 4 (2) #14 SMS PER ! = HINGE WELDED N CONNECTION TO s,: GATE FRAME, TO POST AND POST AND GATE POST, P. TYP. GATE FRAMEx FRAME I: Pi EXISTING 3 KSI EXISTING CONCRETE BARRIER OR N01 SECT (VERIFIED BYFENCE PER WINC OTHERS) ;.Y.;�;f' .. ° ��//� ' .. <Q SEPERATE 4 % ENGINEERING) S 3"0 CORE DRILL, 3" DEEP I*SPACED TO N INTO EXISTING 3 KSI REJECT` 1 3 KSI CONCRETE /f� ",p 0 SEE FOOTER CONCRETE,AND 6"MIN. EDGE A 2"SPHERE FOOTER IN WEL ��' w NOTE DISTANCE FROM CENTER OF COMPACTED SOIL, „••, .,N POST TO ANY CONCRETE FACE TYP 6", FILLED WITH HIGH STRENGTH, TyP 75%OPEN WIND DESIGN REOUIREME Y NON-SHRINK, IRON FREE, MIN.48"POST HEIGHT NON-REACTIVE(4KSI MIN.) POST: HR-4 OR HR-4A - GROUT,TYP. SEE DBL TOP CAP: HR-1 OR HR-10 LEAF FOOTER INTERMEDIATE RAIL: NONE DOUBLE LEAF SWING GATE TABLE GATE FRAME: 1"x 2"x Ys, PICKET: HR-13 SPACED TO JUST REJE bUbl-Ib MINIMUM. VKiVll'VAL J1u111A1UKU NIVU Y IOUNT F EXTRUSION TOLERANCES TO BE PER RAISED SEAL. VALID FOR 50OFT INDUSTRY STANDARDS OF FENCING AT(1)LOCATION - 09 03 4 R74IL, 1 . , PER SEALED DRAWING CHEL D, BISHOP,P.E. (1) #14 x 1"SMS 1=1.000-4 r�4 75&" - �-2.000-1 . -I INTO SCREW - 5r,LID roil(1)JOBq ONLY o aJDgILv!!??I ORN,'BPd.ENGBEERSE . BOSS,TYP. � Z- 0 0.125 ^T Q.04Q o �i 2x2x1/8" 6063-T6 ALUMINUM ANGLE ,ot 314"PICKET HR-13 0 0.066 Z® o (2) #12 x X"SMS ?l-1.000-) W rn U�i o V W PER CLIP,TYP. " oo - W a�IL RAIL GATE FXRAME C� 0.044 SNAP DOST HR-4& Z�+ p W Z"a z X "� ' SNAP PLATE HR-2 —Q w>V W 2 -1:' UI F-Q Q c (7 f 1"PICKET HR-5 t to�5 o Z INTERMEDIATE Z 0 y, F Lu 1L BRACKET s Q.050 0.065 � Wi?r TNT DETAIL 020— >.. 79s 0.097 IL n 3 }— cn oc C" �< SECTION VIEW SNAP PLATE HR-1-i SNAP PLATE HR-2 1 800 O W O % —t LD SNAP POST HR-4A&SNAP PLATE HR-2(PERMITTED ONLY FOR POST t2�10jl �H�HTS UP j7O 48")2.468 z N 0.052 z O °1 0 O ^ TOP CAP HR-1& TOP CAP HR-10L,& U ' p SNAP PLATE HR-2 SNAP PLATE HR-11Q = L9 0 GENERAL NOTES Q Z 9 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THEg m Z REQUIREMENTS OF THE 2010 FLORIDA BUILDING CODE. 2. DESIGN BASED ON ASCE 7-10 USING V„"=IISMPH/V„a=90MPH(3 SEC GUST,UPTO 6'-0" QW 0 N \WITHIN HVHZ),EXPOSURE'D',RISK CATEGORY I,USING THE 'OPEN SIGN METHOD'.70%OPEN U W \ . USED Iii CALCULATIONS. Q �! Z 3. THIS GATE DESIGN TO BE USED AT GROUND SURFACE ONLY,WITH USE LIMITED TO DECORATIVE 1-4 O W •f BARRIER PURPOSES ONLY.THIS GATE IS NOT INTENDED TO MEET CODES GOVERNING ELEVATED -Z 7 O J d + SALCOLIES OR STRUCTURAL RAILINGS. O Q o � 4. ALL FASTENERS TO BE =12 X�a'OR GREATER 2024-T4,18-8 SERIES 300 NON-MAGNETIC T O �/� '•� '�'• �.. ,- // \/, SHALL COSTAITILESS Y WITH S.1.IDCISPECIFICATIO S FOR ALUM.CORROSIONUM PLATED OR OTHERWISE RESISTANT -RES cTIO -H E RIAL AND �L N U AUMINUM ASSOCIATIONINC.,&APPLICABLE FEDERAL STATE,AND LOCAL CODES. J SI CONCRETE S. ALL EXTRUDED MEMBERS SHALL BE ALUMINUM ALLOY TYPE 6061 T6 OR BETTER,U.-N-.0. tr 6. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STFxAG'_i..Lc7 3000 C� , .FOOTER IN WELL PSI U.N.O.AND SHALL BE MINIMUM 1.SX THICKER THAN ANY M 1c R EMBEDMENT.ALi EPDXY G \ $ COMPACTED AND GROUT SHALL MEET OR EXCEED COhiPRE S :E S-11.4--.21-ti C. 'r,E CONCR_EfE Aft SHA.1 BE SOIL TYP. IRON-FREE,NON-SHRINK ACID I:OP.-P.EA SOIL, FIB€RMESH ADMIXTURE PER CY. 7. FOOTER NOTE:FOR HVHZ APPLZCA,x C,%S: FI' ' 8. SURROUNDING SOIL TO BE C0MPA.C` BE CLASSIFIED OR VERIFIED BY C _ i FBZ Il BE SANDY GRAVEL CLASS ON Y. j ~ ROD ASSEMBLY_ '9:.FOR ALUMINUM ATTACH MENTS A I i =r ZED V. H ex: DISTANCE AND 2,SxDIAMETF-:t Y, .O A:). ELEVATION VIEW : oTrlERwlsE. ul r _mac, 10. THE CONTRACTOR i5 RFSPO S_ S_LATE ALL MEMBERS� ; t TO PREVENT ELECTROLYSIS. Z 1�$ JSED FOR ` 11:PER.FBC 424.2.17.2.8:POOL ACCESS _S WHEN PROVIDED SHALL COMPLY VTrT,cC 424.2 ge LICATIONS _AND MUST BE AT LEAST'48'ABOVE CRA &EQUIPPED WITH A SELF CLOSING,SELF LATCHING G W LOCKING DEVICE NOT LESS THA 54FFLuM BOTTOM OF GATE.GATE MUST OPEN OUTWARD TO REMAIN IN AWAY FROM POOL&MUST HAVE NO CPENI G>1/2'WITHIN 18'OF RELEASE MECHANISM.POOL SITION DURING LATCH INSTALLED,PER MANUFACTURER'S RECOMMENDATION AND IS NOT INCLUDED IN THIS � d EVENTS>75MPH 2.FOP 0jl�ATION; d 12 FORNOy P00L APPLICATIONS. ACCESS TO THE GATE SHALL NOT REQUIRE THE USE OF A KEY, TAINED TOOL O SPECIAL KNOWLEDGE ON THE EGRESS SIDE OF THE SWING GATE rA m 13. ELECTRICAL GROUND,WHEN REQUITRrD,TO BE DESIGNED&INSTALLED BY OTHERS. Y W m 14. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF 1 - 0 THIS SPECIFICATION BY CONTRACTOR,et.aL INDEMNIFIES&SAVES HARMLESS THIS ENGINEER FOR ALL COST&DAMAGES IKUDING LEGAL FEES&APPELLATE FEES RESULTING FROM DOUBLE LEAF GATE MATERIAL FABRICATION.SYSTEM ERECTION,CONSTRUCTION PRACTICES BEYOND THAT WHICH COPYR[MffFRAWLSENNARDORE DIA. X DEPTH): IS CALLED FOR BY LOCAL,STATE,&FEDERAL CODES&FROM DEVIATIONS OFTHLS PLAN. POST FOOTER TABLE ( ) IS. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. 00—MPS 10-627 OVERALL GATE OPENING INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR-SUPPLIED DATA AND 8'-O" 9, Q„ 11'-O" MEASUREMENTS.ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY SCALE: Ol WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS.DIMENSIONS ARE SHOWN TO =LU 48" 12"X25" 12"X26" 12"X28" ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA.THEY MAY VARY SLIGHTLY,BUT PAGE DESCRIPTION: 60" 12"X28" 15"X27" 18"X27" MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN.WORK SHALL BE FIELD VERIFIED BY U) OTHERS PRIOR TO CONSTRUCTION.ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN a 72" 1$"x27" OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION oF� PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND SM NOT APPLICABLE INSTALLATION OF MATERIALS.ALTERATIONS OR ADDITIONS TO THIS DOCUMENT ARE NOT r ' PERMITTED AND INVALIDATE OUR CERTIFICATION. LUQ VOTE: FOOTERS DESIGNED PER 16. EXCEPT AS EXPRESSLY PROVIDED HEREIN,NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS =BC 1819.7 AREINTENDED. • ••• 15KTCH &F A. R. TOUSSAINT & ASSOCIATES, INC. •: B O.UN DARY SURVEYFLOR►DA CERTIFICATE AUTHORIZATION N0. LB-273 RVEYORS C-8 BfSCA Yl1fE C.4{1f.4L : • : : •• • : w•: 620 N.E. 126 ST. NORTH MIAMI, FLORIDA 33161 D.H. 1,;'4.87' •:• .:. ••• : •• •FD D.H. PH: (305) 891-7340 FAX: (305) 893-0325 _ FB: 556 PG: 70-71 DATE JAN. 7, 2014 .� 0:7' WIDE CONCRETE SFAWALL .71 _� ORDER No. 1'4896 SCALE: 1" = 20` o� • • ' . ..• C-8 BISCAYNE CANAL ti SCO o�f N,}C�S; s •• �Ca 'UILD/NG, n U a?. �/a .ar 75' 19.15' t5 0 74 13 12 11 10 a 2 .62' 17.33 75' n n » ?� -AS`s s 4a:r5' 4 5 N N.E. 104th STREET s�lp, c c r moo ' 28.52• 75• %9- m-te s�s to c � 12 118-9 >�_ r �• 8 1 70-MM' 75' 1' �I �10.21' .moo LOCATION MAP 9 •.`�' F SCALE: 1"= 400' LEGAL_ DESCRtPTiON: tK 9yc CtR]EIED TO:F - SURVEY OF LOT 15, BLOCK 1, OF 'EVENINGSIDE", C> '� ALEXANDRE ROD[ER AND EMILIE RODtER HIS WIFE ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 44 AT PAGE 33 OF THE PUBLIC RECORDS OF � BISCAYNE MIAMI-DADE COUNTY, FLORIDA BANK, A FLORIDA STATE CHARTERED (Zst COMMERCIAL BANK, ITS SUCCESSORS AND/OR Q SURVEYOR'S CERTIFICATION: ,4 ,QOM ASSIGNS AS THEIR INTEREST MAY APPEAR. WE HEREBY CERTIFY THAT THIS SURVEY IS TRUE AND CORRECT KRIMER & GOLDENT , P.AO THE BEST OF OUR KNOWLEDGE AND BELIEF A5 RECENTLY CONCRETE SURVEYED AND PLATTED UNDER OUR DIRECTION AND THAT THIS SURVEY COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS FOR R Y OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY LAND SURVEYING IN THE STATE OF FLORIDA, UNDER RULE 5J-17 °O FLORIDA ADMINISTRATIVE CODE, CHAPTER 472.027 FLORIDA ?u= LEGEND- STATUTES. NOT VALID WITHOUT THE SIGNATURE AND RAISED SEAL 2`x,05 ;" > OF THE REGISTERED LAND: SURVEYOR SHOWN HEREON. 4gp ti /!„ ! '• A.C. = NIR CONDTER ITIONER J Ce = CONCRETE BL= STU CONCRETE � EN s ErIMT � A.R. T SS NT & ASSOCIATES, INC. FDFOUND o �Q IP = IRON PIPE P- B ` _ PROPERTY LINE LAPID SURVEYOR No. BY: PRES. WM WATER METER ALBERT R. TOUSSAINT 35'05' REGISTERED ENGINEER NO. 8939 E .85 REGISTERED LAND SURVEYOR NO. 907 t' 3 .00' A,S) IWT PAVEMENT STATE OF FLORIDA N 90, ,� ao I N.E. 1-04 th STREET DATE: TITLE FD .I.P 30_ t05 -1 24.5'_ JAN. 7, 2014 1009 N.E. 104th STREET j ci .15(P 41.38(M) FD .P. 35,00' NAIL MIAMI SHORES, FL. 33138 Q Q SCALE 1' = 20' 0 2II 40 60 SCALE: 1 INCH = 20 FEET t 3-17-14 REVISION CERTIFICATION WT AT DRAWING NUMBER SHEET DRAWN BY: REV DATE REVISION DESCRIPTION BY CH COR APR 0. 1 4896 1 OF 1 RS