RF-15-674 t =1
s>+O"Fs y Miami Shores Village 3 Perhr"Vie:R6
3� 10050 N.E.2nd Avenue NW
c
Miami Shores,FL 33138-0000 "P e:
•��tea` Phone: (305)795-2204 APMOS
F�oriio
Issue Cate, ti/2{i`1!S .. Expiration: 09/28/2015
Project Address Parcel Number Applicant
117 NW 94 Street 1131010330720
JULES RAPHAEL
Miami Shores, FL Block: Lot:
�_.�.Owner Information Address 117 NW 94 ST_ Phone Cell
� .n. ,�. ,..�.�. � �.�
JULES RAPHAEL MIAMI SHORES FL 33150-2239
Contractor(s) Phone Cell Phone Valuation: $ 12,800.00
TOP SEAL SERVICES (305)754-7844 Total Sq Feet: 2300
Type of Work:Re Roof Available Inspections:
Additional Info:REROOF TO A NEW COLORTHRU TILE ROOF Inspection Type:
Classification:Residential
Up Lift Report
Scanning:3 Tin Cap
Final Roof
Tile In Progress
Roof in Progress
Renailing Affidavit
Review Roof
Cap Sheet
Fees Due Amount Pay Date Pay Type Amt Paid Amt Due
Bond Type-Contractors Bond $500.00 Invoice# RF-3-15-54935
CCF $7.80 04/01/2015 Check#:30672 $788.80 $50.00
DBPR Fee $4.50
DCA Fee $4.50 03/25/2015 Check#:30662 $50.00 $0.00
Education Surcharge $2.60 Bond#:2657
Permit Fee-New Roof $300.00
Scanning Fee $9.00
Technology Fee $10.40
Total: $838.80
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS, DOORS,ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: T11ceLfythat all the oregoing information is accurate and that all work will be done in compliance with all applicable laws regulating
construction and zonng. ore, I aut rize the above-named contractor to do the work stated.
April 01, 2015
Authorized Si ature:Owner Applicant / Contractor / Agent Date
Building Departm t Copy
April 01, 2015 1
Florida International Engineering and Testing Lab LLC
F * 1 * E * 7500 NW 25 Street,#241, Miami, FL 33122
FLORIDA INTERNATIONAL ENGINEERING Telephone: (305)378-1991-Fax: (305)378-1997
&TESTING LAB
INSIGHT•INNOVATION•INTEGRATION Miami-Dade Lab Certification#07-0612.11-State of Florida ca#27273
---------------------------------------------------------------------------------------------------------------------
SITE SPECIFIC INFORMATION
Owner's Name: -����C. v,11_Ai
Job Address: 14 �• iti ►. iF..t i _ — t—A.-
Roofing Contractor: t i IV 4:X1,2``
Permit Number: h r • _ 4• +-1 r Type of Tile: '3,&
Approximate Roof Height: ( feet Slope: a l Z Approximate Square Footage: 7 4 S"s ft
z
Type of Access to Roof: Ladder
Other Required Testing Force: ( 35 lbs. Testing Equipment: F.G.E. 100x Shim o Instrument
Date Installed: GSIy,�j 1i Date of Inspection: 1
---------------------------------------------------------------------------------------------------------------------
TEST RESULTS
P= PASS, F= FAIL
Test Test Test Test Test
Location P or F Location P or F Location P or F Location P or F Location P or F
1 fj 21 \-6 41 61 81
2 22 42 62 82
3 23 43 63 83
4 24 44 64 84
5 25 45 65 85
6 26 46 1 66 86
7 27 47 67 87
8 28 48 68 88
9 29 49 69 89
10 30 50 70 90
11 31 51 71 91
12 32 1 52 1 72 92
13 33 53 73 93
14 34 54 74 94
15 35 55 75 95
16 36 56 76 96
17 37 57 77 97
18 38 58 78 98
19 39 59 79 99
20 40 60 80 100
--------- -----------------------------------------------------------------------------------------------------------
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106,THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST.
ADDITIONAL TEST INFORMATION
Perimeter Width: S ft RESPECTFULLY SUBMITTED BY:
Area Units or ft2 No.of Tests
Perimeter p C Z
Field ( v C
Corners 2,
Hips& Ridges i Vinayagar M.Balakrishnan V �U( �
State of Florida Lic#63107
FLORIDA INTERNATIONAL ENGINEERING WESTING LAB, LLC
.1
Job Address: ol t-A\Al 14
_ -• 1 ��
Contractor: Talzt
Sketch of Roof
pePY
KQ
r
Ll
Notes
Miami Shores Village R CRI 7ED
Building Department MAR 2 5 2015
f 10050 N.E.2nd Avenue, Miami Shores, Florida 3313
Tel:(305)795-2204 Fax:(305)756-8972 BY•
INSPECTION LINE PHONE NUMBER:(305)762-4949
FBC 20 O
BUILDING Master Permit No. �j - s-
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC Rj ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
F--]PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOBADDRESS: 117 N.W. 94 Street
City: Miami Shores County: Miami Dade Zip: 33150
Folio/Parcel#: 11 -3101 -033-0720 Is the Building Historically Designated:Yes NO x
Occupancy Type:ResidariLoad: Construction Type: Flood Zone: BFE: FIFE:
OWNER: Name(Fee Simple Titleholder): Jules Raphael Phone#: (309) 791-0274
Address: 117 N.W. 94 Street
City: Miami Shores State: Florida zip: 33150
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR:Company Name: Top Seal Services Phone#: (305) 953-3333
Address: 598 N.W. 54 Street
City: Miami State: Florida Zip: 33127
Qualifier Name: Ronald Medina Phone#: (305) 598-3270
State Certification or Registration#: =1330119 Certificate of Competency#:
DESIGNER:Architect/Engineer: Phone#:
Address: City: State: Zip:
Value of Work for this Permit:$ 12,800.00 Square/Linear Footage of Work: 1400sctft. Tile
Type of Work: ❑ Addition 900Sct. Flat
yp ❑ Alteration ❑ New [� Repair/Replace
900t
Demolition
Description of work: Reroof to a new Colorthru Tile roof and Flat Mineral Cap sheet roof.
Specify color of color thru tile: Paradise Island` Tan
Submittal Fee$ W Permit Fee$ 3w W CCF$ CO/CC$
Scanning Fee$ Radon Fee$ DBPR$ Notary$
Technology Fee$ Training/Education Fee$ Double Fee$
Structural Reviews$ Bond$ Z:zna -CD
TOTAL FEE NOW DUE$
(Revised02/24/2014)
Bonding Company's Name(if applicable)
Bonding Company's Address _
City State Zip
Mortgage Lender's Name(if applicable)
Mortgage Lender's Address
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will b ' ered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of c cement ust be po ed at the job site
for the first inspection which occurs seven (7) days after the building permit is issue In th ab nce of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
d
Signature Signature
OWNER or AGENT A
The foregoing instrument was acknowledged before me this The foregoing instr ent /was a nowledged before me this
_ Q 0 day of /�c�„r� 20 /6 by �day of /�lr.-,�,•�(,� 201 ,� by
J kJ t:, Pht�e ( ,who is personally known to f22at,,(C1 / -A� ,who is personally known to
me or who has produced as me or who has produced as
identification and who did take an ath. identification and who did take an oat .
NOTARY PUBLIC: NOTARY PUBLIC:
Sign: Sign:
Print: Print:
r. MARYLOU HE ANDA ey'• MARYLOU HERNANDEZ
Seal: = ''
_ ,- MY COMMISSION A FF 059092 Sea I: _ Y MY COMMISSION ti FF 059092
a. EXPIRES:October 10,2017 1y. Y, EXPIRES:October 10,2017
% f1f ,•' Bonded Thru Notary Public Undenrriters7if Bonded Thru Notary Publ c Underwriters
*************************** ********************************************************************************
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(RevisedO2/24/2014)
Property Search Application - Miami-Dade County Page 1 of 1
OFFICE
OF THE PROPERTY
APPRAISER
Summary Report
Generated On:3/20/2015
Property Information
Folio: 11-3101-033-0720,
Property Address: 117 NW 94 ST
Owner JULES RAPHAEL&W ALOURDES
117 NW 94 ST
Mailing Address
MIAMI SHORES, FL 33150-2239
a
Primary Zone 0800 SGL FAMILY-1701-1900 SQ IAMI
ORES
Primary Land Use 0101 RESIDENTIAL-SINGLE
FAMILY: 1 UNIT
Beds/Baths/Half 13/2/0
Floors 11ilk
Living Units 1
Actual Area 2,028 Sq.Ft
Living Area 11,295 Sq.Ft
Adjusted Area 11,611 Sq.Ft
Lot Size 19,375 Sq.Ft Taxable Value Information
Year Built 11940 20141 20131 2012
Assessment Information County
Year 2014 2013 2012
Exemption Value $50,000 $50,000 $50,000
f
Taxable Value $48,152 $46,702 $45,086
Land Value $126,750 $84,750 $67,500
School Board
Building Value $109,637 $109,775 $123,343
Exemption Value $25,000 $25,000 $25,000
XF Value $1,655 $1,6821 $2,109
Taxable Value $73,152 $71,702 $70,086
Market Value $238,042 $196,2071 $192,952 City
Assessed Value $98,152 $96,7021 $95,086 Exemption Value $50,000 $50,000 $50,000
Benefits Information Taxable Value $48,1521 $46,702 $45,086
Benefit Type 20141 2013 2012 Regional
Save Our Homes Assessment ! Exemption Value $50,0001 $50,000 $50,000
Cap Reduction $139,890 $99,505) $97,866 Taxable Value $48,1521 $46,7021 $45,086
Homestead Exemption ( $25,0001 $25,000 $25,000
Sales Information
Second Homestead Exemption $25,000 $25,000 $25,000
PreviousI OR Book-
Note:Not all benefits are applicable to all Taxable Values(i.e.County, Sale Price{ Pae Qualification Description
School Board,City, Regional). 9
11/01/1989 $75,000 14335-0068 2008 and prior year sales;Qual by
Short Legal Description' exam of deed
MIAMI SHORES SEC 6 PB 10-39 07/01/1977 $47,500 09756-1098 1 Qual by exam of deed
LOT 22&E1/2 LOT 21 ELK 132
LOT SIZE 75.000 X 125
OR 14335-68 1189 1
The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser
and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp
Version:
http://www.miamidade.gov/propertysearch/ 3/20/2015
A
4a- {
•, y i
f #
NOAl2-0222.02
Raspberry Sorbet Paradise Island Tan
--''DARD 1 HBCS7530 STANDARD 1 HBCS0084 /17 �),LJ, 9 4� 3- STANDARD
y
In Stock in Lake Wales; Made to Order in Pompano Made to Order in Lake Wales and Pompano
i
I
Belleair Beach Blend Irving Blend
-=�D 1 HBCS6258 STANDARD 1 HBCS6255 STANDARD
E i
i
I
i
j �;.
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES ECE'VF
: .MAR 5 2015
Florida Building Code Edition 2010
High-Velocity Hurricane Zone Uniform Permit Application Form.
Section A(General Information
Master Permit No.
' Process No.
Contractor's Name Top Seal Services
Job Address 117 N.W. 94 Street
ROOF CATEGORY
M Low Slope ❑ Mechanically Fastened Tile ? Mortar/Adhesive Set Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF TYPE
❑ New Roof IX Reroofing ❑ Recovering ❑ Repair ❑ Maintenance
ROOF SYSTEM
INFORMATION
Low Slope Roof Area(SF)900sgft. Steep Sloped Roof Area(SF)1400sgft. Total(SF) 2300sgft.
Section B (Roof Plan)
Sketch Roof Plan:Illustrate all levels and sections,roof drains,scuppers,overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of
parapets.
34`
i
i
I �L4 3 14 — Ila
i
15.34 2010 FLORIDA BUILDING CODE—BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 201
High-Velocity Hurricane Zone Uniform Permit Application Form.
Section C(Low Slope Application) Surfacing: N/A
Fill in specific roof assembly components
and identify manufacturer Fastener Spacing for Anchor/Base Sheet Attachment:
(If a component is not used,Identify as"NA")
Field: 9 "oc @ Lap,#Rows 2 @ 9 "oc
System Manufacturer: GAF
Perimeter: 6 "oc @ Lap,#Rows 4 @ 6 "oc
Product Approval No.: 13-1022 - .15
Corner: 6 "oc @ Lap,#Rows 4 @ 6 "oc
Design Wind Pressures,From RAS 128 or Calculations:
:
P2: -71 .
P1: 7 P3: —108.0
—42.8 Number of Fasteners Per Insulation Board:
Max.Design Pressure,from the specific Product Field N/A Perimeter N/A CornerNLA_ C
Approval system: —52.5
Illustrate Components Noted and Details as
Deck: Applicable:
Type:--','700d Woodblocking,Cutter, Edge Termination, Stripping,
Flashing,Continuous Cleat, Cant Strip, Base Flashing,
Gauge/Thickness: 1 XS Counter-Flashing,Coping, Etc.
5 Indicate: Mean Rdof Height, Parapet Height, Height of
Slope:-- Base Flashing,Component Material,Material Thickness, c
Fastener-Type, Fastener Spacing or Submit Manufactur-
Anchor/Base Sheet&No.of Ply(s):N/A ers Details that Comply with RAS 111 and Chapter 16
Anchor/Base Sheet Fastener/Bonding Material: -
_ N/A a
I5 gee'l �� N(
Insulation Base Layer: N/A
gee
v �► ��
Base Insulation Size and Thickness: N/A S
�leiM � FT. N/A
Base Insulation Fastener/Bonding Material:
/A
Parapet :
') Height
Top Insulation Layer: N/A
a
■
Top Insulation Size and Thickness:N/A
Top Insulation Fastener/Bonding Material:
N/A W oc zc�- Mean
Roof
Base Sheet(s)&No-of Ply(s): (1 ) #75 base sheet Height
Base4heetRFsrtener/Bonding Material:
" _ nails (0�
Ply Sheets)&No.of ply(s): 2 plies of ply 4
Ply Sheet Fastener/Bonding Material:
Type 1V. mopping asphalt
Top Ply: 0 )_layer of Mineral Cap sheet
•
T�p Pty Fastener/Bonding Material:
'1'YPe V mgping asRhalt
2010 FLORIDA BUILDING CODE--BUILDING 15.35
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
High-Velocity Hurricane Zone Uniform Permit Application Form.
Seaton d $tggp Slope Roof $y tem,l
i
Roof System Manufacturer: Boral Roofing, LLC
Notice of Acceptance Number: 12-0222.02
w
Minimum Design Wind Pressures, If Applicable (From RAS 127 or
Calculations):
a
1• -39.1 P2. -68.1P3. -100.7
r
F
i
i
r
R
w
w
i
i
i
i
w
i
SA 511 .pe4-F_-00SYste-LI)w.egrWi.m
i
r
r
f
i
w
i
---_.___... ------
_----
Deck Type. �
r \.
w .1_. 6 -
---- --- _ - .---- -
i
___- Type Underlayment (1 ) 301b. ASTM D-226 I
Roof Slope: _._ _
` 3 12 ---- - --
_ -_._-_._,.__._.
Insulation: IN/A
Fare Barrier: 1 N/A
1 'e �. - ---------._". J.L.
Ridge Ventilation? i -t� s
g N A Fastener Type&Spacing: (1--1/4" RIS nails2 rows 12" /c
Adhesive Type
-41 foam adhesive settin ..._._... _.
° _.( .
t Type Cap Sheet: self adhering
.----------------
_
Mean Roof Height: 13 g: Boral Barcelona Roof Covering: 900„ -` `"`i
�
� 1
r Type&Size
w �
Drip Edge.,
i
-------.---__.___-,_.._s
i
i
i
i
� ��.«.....«.b_>..,.....�s..._._.__—•_--_.... _-......«ate,.. .«..-.................... _--<,.....�. - n+b»�..-+._+�
R
15.36 2010 FLORIDA BUILDING CODE—BUILDING
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florida Building Code Edition 2010
High-Velocity Hurricane Zone Uniform Permit Application Form. ;
E13al Baroelcm 900 Section E (Tile CalcaalationsZ
For Moment based tile systems,choose either Method 1 or 2.Comparethe values for Mr with the values from Mf.If the Mf values are greater than or
equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable. o
e
Method I"Moment Based Tile Calculations Per RAS 127"
(PI,-39.1 XX-313 =12.24)-Mg; 8*0E-j6 k14.19 Product Approval Mf 29.3 t1,0 patty
(P2;-68-1x%-31-4 =21.32)-Mg: R_05=Mr213_2.7 Product Approval Mf_22.a tFD patty
(P3-IQQl x x-313 =31-52).Mg: 8-05 =Mr3 23-47 Product Approval Mf 29.3 tFD pate
Method 2"Simplified Tile Calculations Per Table Below"
•
Required Moment of Resistance(Mr)From Table Below Product Approval Mf
a
Mr required Moment Resistance*
e
Hei
MeanRoof SI0>egh4 15' 20' 25' 30' 40'
F v
2:12 34.4 36.5 38.2 39.7 42.2 ;
3:12 $2.2 34.4 36.0 37.4 39.8
4:12 30.4 32.2 33.8 $5.1 37.3
•
5:12 28.4 30.1 31.6 32.6 34.9
6:12 26.4 28.0 29.4 30.5 32.4 a
7:12 24.4 25.9 27.1 28.2 30.0
*Must be used in conjunction with a list of moment based die systems endorsed by the Broward County Board of Rules and Appeals.
Por Uplift based die systems use Method 3.Compared the values for Fwith the values for Fr.If the F'values are greater than or equal to the Fr values,
for each area of the roof,then the tile attachment method is acceptable. o
Method 3"Uplift Based Tile Calculations Per RAS 127"
(PI; x L = x w:= �•W: x cos t3 =FrI Product Approval 1
•
(P2: x L = x w:= -W: x cos B =Fr2 Product Approval F' o
(P3: x L = x w:=_)-W; x cos 8 =Fr3 Product Approval 1
a
Where to Obtain information
Description Symbol Where to find
Design Pressure PI or P2 or P3 RAS 127 Table 1 or by an engineeri ng analysis prepared by PE based on ASCE 7 0
o
Mean Roof Height H Job Site o
Roof Slope B Job Site
Aerodynamic Multiplier Product Approval
;
Restoring Moment due to Gravity M Product Approval
Attachment Resistance Mf Product Approval
Required Moment Resistance M Calculated
Minimum Attachment Resistance F, Product Approval
a
Required Uplift Resistance Fr Calculated ;
Average Tile Weight W Product Approval tl
oTile Dimensions L=length Product Approval .
W=width
All calculations must be submitted to the building official at the time of permit application.
2010 FLORIDA BUILDING CODE-BUILDING 15.37
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the
owner with the required roofing permit,and to explain to the owner the content of this section.The provisions of
Section R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner and the
contractor.The owner's initial in the adjacent box indicates that the item has been explained.
1.Aesthetics-Workmanship:The workmanship provisions of Section R4402 are for the purpose of
providing that the roofing system meets the wind resistance and water intrusion performance standards.Aesthetics
(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color
or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement
between the owner and the contractor.
2. Renailing Wood Decks: When replacing roofing,the existing wood roof deck may have to be
ren ed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
t emoving the existing roof system.)
3. Common Roofs: Common roofs are those which have no visible delineation between
nei hboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing
contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed.
` 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking
ca a viewed from below.The owner may wish to maintain the architectural appearance, therefore, roofing
nail penetrations of the underside of the decking may not be acceptable.This provides the option of maintaining
this appearance.
r
5. Ponding Water: The current roof system and/or deck of the building may not drain well and
m cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of
structural distress and may require the review of a professional structural engineer. Ponding may shorten
the life expectancy and performance of the new roofing system. Ponding conditions may not be evident
until the original roofing system is removed. Ponding conditions should be corrected.
r 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
0 oaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge
if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
int i r of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of
the roof.
Exception:Attic spaces,designed by a Florida licensed engineer or registered chitCeliminate the attic
venting,venting s not be required.
.— �
O er / gent's Signature Date ConttWr ` Sign A
17 ALr
Property Address Permit Number
M1® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/oera
Boral Roofing,LLC
7575 Irvine Center Drive, Suite 100
Irvine,CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section
to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Barcelona 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any
section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be
done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA#07-0220.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0222.02
MAWDADE COUNTY �tv' Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 1 of 7
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Roofing Tiles
Material: Concrete
Deck Type: Wood
1. SCOPE
This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral
Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where
the pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in the
installation section herein. The attachment calculations shall be done as a moment based system..
2. PRODUCT DESCRIPTION
Manufactured by Test Product
Applicant Dimensions Specifications Description
Barcelona 900 1= 17" TAS 112 High profile, interlocking, one-piece,'S'
w= 13" shaped,high-pressure extruded concrete roof
'/2"thick tile equipped with three nail holes. For direct
deck or battened nail-on,mechanically
fastened,mortar set or adhesive set
applications.
Trim Pieces Length:varies TAS-112 Accessory trim,boosted Barcelona,concrete
Width:varies roof pieces for use at hips,rakes,ridges and
varying thickness valley terminations manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
2.1.1. Lake Wales,FL.
2.2 SUBMITTED EVIDENCE:
Test Agency Test Identifier Test Name/Report Date
Redland Technologies 7161-03 Static Uplift Testing Dec. 1991
Appendix III TAS 102&TAS 102(A)
Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991
Appendix 11 TAS 108(Nail-On)
Redland Technologies P0402 Withdrawal Resistance Sept. 1993
Testing of screw vs. smooth
shank nails
Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994
1994 TAS 108 (Nail-On)
NOA No.: 12-0222.02
MIAMMDiADE COUNTY Expiration Date: 04/26/17
W Approval Date: 04/19/12
Page 2 of 7
r •
Redland Technologies P0631-01 Wind Tunnel Testing July 1994
TAS 108(Mortar Set)
Professional Service Industries, IC-1320-94 Physical Properties Feb. 1995
Inc. TAS 112
The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996
Engineering,Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996
The Center for Applied 25-7688-5 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(3" Headlap,Nails,Direct
Deck,New Construction)
The Center for Applied 25-7688-4 Static Uplift Testing June 1996
Engineering,Inc. TAS 102
(4" Headlap,Nails,Clips)
Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998
Testing Services 520191-2-1 TAS 101 March 1999
Walker Engineering,Inc. Calculations Aerodynamic Multiplier March 1999
Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999
System
Walker Engineering,Inc. Evaluation 25-7183 March 1995
Calculations
Walker Engineering,Inc. Evaluation 25-7094 February 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7496 April 1996
Calculations
Walker Engineering,Inc. Evaluation 25-7584 December 1996
Calculations 25-7804b-8
25-7804-4&5
25-7848-6
Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007
Calculations Gravity
Nutting Engineers 122 TAS 112 January 2007
A" AnENOA No.: 12-0222.02
MIAMF lalmte COUNTY Expiration Date: 04/26/17
• Approval Date: 04/19/12
Page 3 of 7
� t
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in
accordance with TAS 106.
3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform
quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to
the Building Code Compliance Office for review.
3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications
Standards listed section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope
unless stated otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in
compliance with the applicable Building Code.
4. INSTALLATION
4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance
with Roofing Application Standard RAS 118,RAS 119,and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight(W) and Dimensions (I x w )
Tile Profile Weight-W(lbf) Length-1 (ft) Width-w (ft)
Barcelona 900 11.5 1.417 1.08
Table 2: Aerodynamic Multipliers -A,(ft?)
Tile '%(ft ) X(ft)
Profile Batten Application Direct Deck Application
Barcelona 900 0.289 0.313
Table 3: Restoring Moments due to Gravity - M9 (ft-lbf)
Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or
Profile greater
Barcelona Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct
900 Deck Deck Deck Deck Deck Deck
7.28 8.13 7.21 8.05 7.10 7.93 6.96 7.78 6.79 7.61 6.61 7.40
NOA No.: 12-0222.02
CMIAMMADECM0 Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment- Mf(ft-Ibf)
for Nail-On Systems
Tile Fastener Type Direct Deck Direct Deck Battens
Profile (min 15/32" (min. 19/32"
plywood) plywood)
Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4
1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8
2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3
1 .#8 Screw 20.7 20.7 18.1
2 48 Screws 43.2 43.2 29.8
1-10d Smooth or Screw Shank Nail 23.1 23.1 19.0
Field Clip)
1-10d Smooth or Screw Shank Nail 29.3 29.3 24.0
Eave Clip)
2-10d Smooth or Screw Shank Nails 27.6 27.6 38.6
Field Clip)
2-10d Smooth or Screw Shank Nails 38.1 38.1 41.8
Eave Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf(ft-Ibf)
for Two Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Adhesive 29.3
1 See manufactures component approval for installation requirements.
2 Dow Chemical TileBond Average weight per patty 10.7 grams.
Pol foam Product, Inc.Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf)
for Single Patty Adhesive Set Systems
Tile Tile Application Minimum Attachment
Profile Resistance
Barcelona 900 Polyfoam Pol Pro TM 66.5
Polyfoam Pol ProM 38.7
3 Large paddy placement of 63 rams of Pol Pro TM
4 Medium paddy placement of 24 rams of Pol ProTm.
Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-Ibf)
for Mortar Set Systems
Tile Tile Attachment
Profile Application Resistance
Barcelona 900 Mortar Set 24.5
5. Tile-Tite Roof Tile Mortar
NOA No.: 12-0222.02
MLAMFMDe COU Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 5 of 7
s ,
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as
detailed below,or following statement: "Miami-Dade County Product Control Approved".
LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2)
LOCATED UNDERNEATH TILE
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code
in order to properly evaluate the installation of this system.
NOA No.: 12-0222.02
MIAMNDADE COUNTY Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 6 of 7
PROFILE DRAWING
NAIL HOLES
OVERLOCK
3 5/8"
17 "
13"
UNDERLOCK
BARCELONA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 12-0222.02
MAMMADE COUNTY= Expiration Date: 04/26/17
Approval Date: 04/19/12
Page 7 of 7
MIAM
MIAMI-DADE COUNTY
ME PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Polyglass USA Inc.
150 Lyon Drive
Fernley,NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA#11-1229.01 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
MIAMNDADE COUNTY NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page l of 8
� 4
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub-Catep-ory: Underlayment
Material: SBS , APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt
underlayment 65'8" x 3'3-3/8" waterproofing membrane, glass fiber reinforced
Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for
#2 use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
Polystick IR-Xe Roll: TAS 103 and A fine granular/sand top surface self-adhering,
underlayment 65' x 3'3-'/8" ASTM D 1970 APP polymer modified, fiberglass reinforced,
Manufacturing Location Or 65' x 3' bituminous sheet material for use as an
#1 & #2 60 mils thick underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP
underlayment 32'10"x 3'33/8" ASTM D 1970 polymer modified, fiberglass or polyester
Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as
#1 & #2 an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self-adhering, glass-
underlayment 65' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing
(Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof
Manufacturing Location tile underlayment.
#1 & #2
Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane,
underlayment 32'10"x 3'3-'/8" ASTM D 1970 glass-fiber/polyester reinforced, with a granular
Manufacturing Location 130 mils thick surface designed for use as a tile roof
#2 underlayment.
Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self-adhering, glass-
Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and roof
tile underlayment.
Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self-adhering, glass-
Manufacturing Location 61' x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproofing
#2 60 mils thick membrane. Designed as a metal roofing and
roof tile underlayment.
NOA No.: 12-0713.02
MIAMI•DADE COUNTY Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 2 of 8
r �
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick TU Max Roll: TAS 103 and A rubberized asphalt self-adhering, polyester
Manufacturing Location 65'8" x3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed
#2 60 mils thick as a a roof tile underlayment.
MANUFACTURING PLANTS:
1.Hazelton, PA
2.Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01
11756.08.01-1 ASTM D 1970 08/14/01
02202.08.05 TAS 103 08/29/05
Trinity I ERD P5110.08.07 TAS 103 08/29/07
P10870.09.08-R1 TAS 103 12/04/08
PI 0870.04.09 TAS 103/ASTM D4798 & G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.1I TAS 103 03/02/11
P33370.04.1 I ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11
P40390. 08.12-1 TAS 103 & TAS 110 08/06/12
P40390.08.12-2 ASTM D 1623 08/07/12
P40390.10.12 ASTM D 1970 10/03/12
PRI Asphalt Technologies PRI01 I I l ASTM D 4977 04/08/02
PUSA-005-02-01 ASTM D 4977 01/31/02
PUSA-018-02-01 ASTM D 2523 07/14/03
PUSA-035-02-01 TAS 103 09/29/06
PUSA-033-02-01 ASTM D 1970 01/12/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-083-02-01 TAS 103 06/30/08
PUSA-089-02-01 TAS 103/ASTM D4798 & G 15 5 07/06/09
Momentum Technologies, Inc. JX201-17A TAS 103/ASTM D4798 & G 15 5 04/01/08
RX14E8A TAS 103/ASTM D4798 & G155 11/09/09
DX23D813 TAS 103/ASTM D4798 &G155 02/18/10
DX231)8A TAS 103/ASTM D4798 & G155 02/18/10
MIAMI•DADE COUNOA No.: 12-0713.02
NTY
• Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 3 of 8
� 1
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non-insulated
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self-adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-'/a"and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 12-0713.02
QMIAMMIQ�AQE CO=UNTYExpiration Date: 09/13/16
Approval Date: 02/14/13
Page 4 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles,
non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR-Xe, TU, and TU
P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in
roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations da s
MTS IR-Xe TU TU Plus TU P Tile Pro Dual Pro TU Max
Winter Haven,FL. 180 180 180 180 180 180 180 90
Hazelton,PA. N/A 30 30 180 N/A N/A N/A N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both
adhesive set and mechanically fastened roof tile applications. Polystick IR-Xe, and Dual Pro are limited to
mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens
roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for(direct-to-deck)tile assemblies shall be as
follows: (See Table Below)
Tile Profile Polystick MTS Polystick IR-Xe Polystick TU,TU Polystick TU
Plus,TU P,Tile Max
Pro
Flat Tile Prohibited without 5:12 No limitation No limitation
battens
Profiled Tile Prohibited without Prohibited No limitation No limitation
battens
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
MIAM4DADE COUNTY NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
I
i
Roofing Tiles
------------ --------_- (6 Max Per Stack)
I
I
I
i
M 12
c 6 —
W A
Rnof Deck prepared with
POLYS-nCKTU Plus
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, TU Max, Dual Pro and
Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR-Xe,
TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of
Acceptance. If Polystick MTS, IR-Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a
request may be made to the Authority Having Jurisdiction (AHJ)or the Miami-Dade County Product Control
Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami-Dade County Product Control
Approved" or the Miami-Dade County Product Control Seal as shown below.
QMIAMWMOUNTY
...l
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 12-0713.02
MIAMI•DAD;COUNTY Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back-nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1"metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12"o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar"on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back-nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams(selvage laps)must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6"wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic
between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations#9 and#10.
6. Battens and/or Counter-battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of TV 12"or greater. It is suggested that on pitch/slopes in excess of 6 'A"/12", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation&before loading of roofing tiles is Forty-Eight(48)Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set
and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6
inches in either direction. The repair should be installed in such a way so that water will run parallel to or
over the top of all laps of the patch.
10. All self-adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami-Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894-4563.
MIAMNDADE COUNTY
NOA No.: 12-0713.02
• Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association(NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 12-0713.02
MIAMI-DAD,COUNTY Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 8 of 8
MIAM MIAMI-DADE COUNTY
MMIDPRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/sera
3M Company
3M Center Building 0220-05-E-06
St.Paul,MN. 55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County PERA-Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right
to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3Mrm 2-Component Foam Roof Tile Adhesive AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA# 11-0124.04 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
Y
NOA No.: 12-0228.18
Expiration Date: 05/10/17
Muv�i•aewecouNrr Approval Date: 05/10/12
FU=sa
Page 1 of 7
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as
determined by applicable building code, does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles
system using 2-Component Foam Roof Tile Adhesive AH-160. Where the attachment calculations are done as a
moment based system for single patty placement,and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2-Component Foam N/A TAS 101 Two component polyurethane foam adhesive
Roof Tile Adhesive AH-
160
Foam Dispenser RTF 1000 N/A Dispensing Equipment
ProPack®30& 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160
roof tile adhesive.
MANUFACTURING LOCATION:
1. Tomball,TX.
PHYSICAL PROPERTIES:
Prope Test Results
Density ASTM D 1622 1.6 lbs./ft.'
Compressive Strength ASTM D 1621 18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile Strength ASTM D 1623 28 PSI Parallel to rise
Water Absorption ASTM D 2127 0.08 Lbs./Fe
Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch
Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40°F., 2 weeks
+6.0%Volume Change @158°F., 100%Humidity, 2
weeks
Closed Cell Content ASTM D 2856 86%
NOA No.: 12-0228.18
MIAMI•DADECOUNTY Expiration Date: 05/10/17
�gj...e , Approval Date: 05/10/12
Page 2 of 7
Note: The physical properties listed above are presented as typical average values as determined
by accepted ASTM test methods and are subject to normal manufacturing variation.
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
Center for Applied Engineering #94-060 TAS 101 04/08/94
257818-IPA TAS 101 12/16/96
25-7438-3 SSTD 11-93 10/25/95
25-7438-4
25-7438-7 SSTD 11-93 11/02/95
25-7492 SSTD 11-93 12/12/95
Miles Laboratories NB-589-631 ASTM D 1623 02/01/94
Polymers Division
Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93
Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94
01-6739-062b[l] ASTM E 84 01/16/95
Trinity Engineering 7050.02.96-1 TAS 114 03/14/96
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat, low, &high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101.
5. Roof Tile manufactures acquiring acceptance for the use of HANDI-STICK roof tile adhesive with their tile
assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein.
FFW
F'=
MS
NOA No.: 12-0228.18
MIAMI-DADE COUNTY Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 3 of 7
INSTALLATION:
1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160.
2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof the assembly's adhesive
attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient
attachment resistance, expressed as an uplift based system,to meet or exceed the uplift resistance determined in
compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH-
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0
(B). The dispense timer shall be set to deliver 0.0175 to 0.15 pounds per tile as determined at calibration. No
other settings shall be approved.
6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or
ProPack®30 & 100 dispensing equipment only.
7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 2 to 3 minutes after 3MTM 2-
Component Foam Roof Tile Adhesive AH-160 has been dispensed.
9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in
accordance with the'Placement Details'herein. Each generic tile profile requires the specific placement noted
herein.
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile Placement Detail Single Paddy Weight Two Paddy Weight per
Min.(grams) paddy Min. (grams)
Flat,Low, High Profiles #1 35 N/A
High Profile(2 Piece Barrel) #1 17/side on cap and 34/ an N/A
Flat,Low, High Profiles #2 24 N/A
Flat,Low, High Profiles #3 8
NOA No.: 12-0228.18
MIAMI•DADE COUNTY Expiration Date: 05/10/17
� Approval Date: 05/10/12
Page 4 of 7
LABELING:
All 3MTM 2-Component Foam Roof Tile Adhesive AH-160 containers shall comply with the Standard Conditions
listed herein.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
ADHESIVE PLACEMENT DETAIL 1
SINGLE PATTY
Nail through plastic cement Paddy(Beneath Tile) Nail through plastic cement
Paddy(Beneath Tile)
Underiayment Underiayment
10 in.
`-2 in
Eave Course
Fascia Eave Course Fascia
Weephde
Eave course only: Eave course only: Eave closure
Eave Closure Keep adhesive approx. Keep adhesive approx. Drip edge
4 in.up from weepholes 4 in.up from weepholes
Nail through plastic cement Paddy(Beneath Tile) Option 4s for
1)Place enough adhesive to achieve n l 23 steep pitch applications Nail through plastic cement
Undedayment _--__ square inches in contact with the pantile
2)Turn covers upsidedown.Place adhesive 112 in.
To 1 in.From outside edge of cover tile.
Then install the tile. o
_ = Und'daymerd
10 in.
2 in.
Eave Course
Eave Closure _
Remov = _
Eave ceurse only: top portion
Keep adhesive approx.4 in.up Fascia of the save = Sheathing
from weepholes course cover tile.
Abut to second course of Optional
pan tiles.Ensure eave end of Point u Mortar
pan and cover tiles are P
flush at eave line. on longitudinal
edges of file
Eave closure Weephde Fasda
(mortarshown)
NOA No.: 12-0228.18
MIAMI•QADE COUNTY
Expiration Date: 05/10/17
• e Approval Date: 05/10/12
Page 5 of 7
ADHESIVE PLACEMENT DETAIL 2
SINGLE PATTY
Nail through Plastic cement Paddy(Beneath Tile) Nail through Plastic cement Paddy(Beneath Tile)
Underlayment Underlayment
e
7 in. . 2 in.
7 in.
vr 2 in.
Eave Course
Fascia Fascia
Weephole
%Eave Course Eave closure
Drip edge
Eave Closure
Nail through Plastic cement Paddy(Beneath Tile)
Undedayment
in.
Eave Closure
Eave Course Fascia
NOA No.: 12-0228.18
Expiration Date: 05/10/17
MLAWDAIDE COUNTY Approval Date: 05/10/12
IFT111:192311 Page 6 of 7
ADHESIVE PLACEMENT DETAIL 3
DOUBLE PATTY
Nail through plastic cement Paddy Nail through plastic cement Single paddy under tile
(between file) Undedayment Single paddy between file
Paddy 2 in.x 7 in.medium
(under file) size paddy eave
course only
Single Paddy S3 n.x 3 in.
Sin. under tie
x 3 in.
g4 in. 2 in. --------
Single paddy on 0 2 in. 4 in. pSingle
le on
under-
layment under-
layment
Single paddy Fascia
have course on top of tile Weephole
Single paddy 2 in.X 7 in.medium Eave Eave closure
on top of filesize paddy eave % Course Drip edge
Fascia course only
Nail through plastic cement Single paddy
under file Single paddy
between tile
3 in.x 3 in. 4i
Single paddy
on undedayment 2 n.
Single paddy Eave Closure
on top of the 2 in.x 7 in.medium
size paddy eave course only
Eave Course Fascia
L
END OF THIS ACCEPTANCE
NOA No.: 12-0228.18
MAMI-DARE COUNTY M Expiration Date: 05/10/17
Approval Date: 05/10/12
Page 7 of 7
t •
MIAMI- MIAMI-DADE COUNTY
� PRODUCT CONTROL SECTION
11805 SW 26 Street,Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/eeonomv
GAF
1361 Alps Road
Wayne,NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product
Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Conventional Built-Up Roof Systems for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0424.09 and consists of pages 1 through 16.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 13-1022.15
CMIAMI-DADERUONTY Expiration Date: 11/04/18
APPROVED:
Approval Date: 11/06/14
Page 1 of 16
t
ROOFING SYSTEM APPROVAL
Cateizory: Roofing
Sub-Catezory: BUR
Material: Fiberglass
Deck Type: Wood
Maximum Desien Pressure: -75 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
GAFGLAS4'#75 Base 39.37" (1 meter) ASTM D4601 Type II asphalt impregnated and coated glass mat
Sheet Wide base sheet.
GAFGLAS#80 UltimaTM 39.37"(1 meter) ASTM D4601 Type II asphalt impregnated and coated, fiberglass
Base Sheet Wide base sheet.
GAFGLAS®FlexPly'm 6 39.37" (1 meter) ASTM D2178 Type VI asphalt impregnated glass felt with asphalt
Wide coating.
GAFGLAS® Ply 4 39.37"(1 meter) ASTM D2178 Type IV asphalt impregnated glass felt with asphalt
Wide coating.
GAFGLAS° Mineral 39.37" (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet surfaced
Surfaced Cap Sheet Wide with mineral granules.
GAFGLAS® EnergyCapTM 39.37"(1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet surfaced
BUR Mineral Surface wide with mineral granules with factory applied
Cap Sheet EnergyCoteTM
GAFGLAS® Stratavent®R 39.37'(1 meter) ASTM D4897 Fiberglass base sheet coated on both sides with
Eliminator TM Perforated Wide asphalt. Surfaced on the bottom side with mineral
Venting Base Sheet granules embedded in asphaltic coating with factory
perforations.
GAFGLAS® Stratavent° 39.37' (1 meter) ASTM D4897 A nailable, fiberglass base sheet impregnated and
EliminatorTMNailable Wide coated on both sides with asphalt. Surfaced on the
Venting Base Sheet bottom side with mineral granules embedded in
asphaltic coating.
Ruberoid®R SBS Heat- 39.37'(1 meter) ASTM D6164 Non-Woven Polyester mat coated with polymer-
Weld TM Smooth Wide modified asphalt and smooth surfaced.
Ruberoid° SBS Heat- 39.37'(1 meter) ASTM D6164 Non-Woven Polyester mat coated with polymer-
WeldTM 25 Wide modified asphalt and smooth surfaced.
Ruberoid®20 39.37'(1 meter) ASTM D6163 SBS modified asphalt base sheet reinforce with a
Wide glass fiber mat.
Ruberoid Mop Smooth 39.37'(1 meter) ASTM D6164 Non-woven polyester mat coated with polymer-
wide modified asphalt and smooth surfaced.
NOA No.: 13-1022.15
MIAMI•DADECOUNTY Expiration Date: 11/04/18
• Approval Date: 11/06/14
Page 2 of 16
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
FireOutTM Fire Barrier 5, 55 gallons Proprietary Low VOC, water based fire barrier coating.
Coating
VersaShield°Fire 350 sq. ft. roll ASTM D226 Non-Asphaltic Fiberglass-Based Underlayment.
Resistant Roof Deck
Protection
Topcoat" Surface 'Seal 5 gallons ASTM D6083 Solvent based sprayable thermoplastic rubber
SB sealant designed to protect and restore aged roof
surfaces and to increase a roofs reflectivity.
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
EnergyGuardTM Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuardTM RA Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuardTM RN Polyiso Insulation Polyisocyanurate foam insulation GAF
EnergyGuardTM Perlite Roof Insulation Perlite insulation board. GAF
EnergyGuardTM Perlite Recover Board Perlite recover board GAF
EnergyGuardTM RA'Composite Polyiso Polyisocyanurate foam insulation with high GAF
Insulation density fiberboard or Permalite perlite
insulation
SecurocO Gypsum-Fiber Roof Board Gypsum roof board United States Gypsum Corp.
Structodek*High Dlensity Fiber Board High density fiber board Blue Ridge Fiberboard, Inc.
DensDeck®Roof Board Gypsum board Georgia-Pacific Gypsum LLC
NOA No.: 13-1022.15
MIAMI•DADECOUNTY Expiration Date: 11/04/18
PPR
40—
• ' Approval Date: 11/06/14
Page 3 of 16
. 5
APPROVED FASTENERS:
TABLE 3
Fastener Product Product Manufacturer
Number Name Description Dimensions (With Current NOA)
1. Drill-TecTM#12 Fastener Insulation fastener for steel, various GAF
wood& concrete decks.
2. Drill-TecTM#14 Fastener Insulation fastener for steel, various GAF
wood& concrete decks.
3. Drill-TecTM XHD Fastener Carbon steel extra heavy duty Various GAF
fastener used in steel decks.
4. Drill-TecTM ASAP 3S Drill-TecTM#12 Fastener with Various GAF
Drill-TecTM 3" Standard Steel
Plate
5. Drill-TecTM 3" Steel Plate Round galvalume stress plate 3"round GAF
used with Drill-TecTM
fasteners.
6. Drill-TecTM 3" Standard Steel Round galvalume plated steel 3" round GAF
Plate stress plate with reinforced
ribs for use with Drill-TecTM
fasteners.
7. Drill-TecTM AccuTrac"Flat AZ-SS aluminized steel plate 3" square GAF
Plate for use with Drill-TecTM#12
Fastener, Drill-TecTM#14
Fastener and Drill-TecTM#15
Fastener.
8. Drill-TecTM AccuTrac° Galvalume Steel plate for use 3" square GAF
Recessed Plate with Drill-TecTM fasteners.
NOA No.: 13-1022.15
MIAMI-DADE COUNTYM Expiration Date: 11/04/18
Approval Date: 11/06/14
Page 4 of 16
EVIDENCE SUBMITTED:
Test Agency Test Identifier Description Date
Factory Mutual Resjearch Corp. J.1. 2138A4.AM 4470 07/02/97
J.I. 3139QLAM 4470 01/08/98
J.I. ODOA8.AM 4470 07/09/99
J.I. OD lA8.AM 4470 07/29/94
J.I. OY9Q5.AM 4470 04/01/98
3029832 4470 05/11/07
UL LLC R1306 UL 790 07/22/13
PRI Construction Materials GAF-012-02-02 ASTM D4977 11/06/01
Technologies, LLC', GAF-020-02-01 ASTM D4977 02/01/02
GAF-082-02-01 ASTM D6083 05/07/06
GAF-084-02-01 ASTM D6083 05/09/06
GAF-270-02-02 ASTM D226 11/15/10
GAF-276-02-01 Rev ASTM D6083 12/16/10
GAF-276-02-02 ASTM D226 11/15/l0
GAF-306-02-01 ASTM E96 07/07/11
GAF-314-02-01 ASTM D2178 08/23/11
GAF-315-02-01 ASTM D2178 08/23/11
GAF-369-02-01 ASTM C1289 10/22/12
GAF-417-02-01 ASTM C1289 05/28/13
GAF-464-02-01 ASTM C1289 10/22/12
GAF-499-02-01 ASTM D6083 03/12/14
GAF-500-02-01 ASTM D6083 03/12/14
IRT of S. Fl. 02-005 TAS 114 01/18/02
02-014 TAS 114 03/22/02
Trinity I ERD 630250.02.10-3-R1 ASTM D3909 11/26/12
G31360.03.10 ASTM D6164 03/31/10
G33470.01.11 ASTM D6164 11/16/11
G34140.04.11-2 ASTM D6163 04/25/11
G34140.04.11-4 ASTM D6401 04/25/11
G34140.04.11-5 ASTM D4897 04/25/11
G34140.04.11-5-R1 ASTM D4897 10/18/13
G40630.01.14-2A-1 ASTM D6164 01/07/14
G43610.01.14 ASTM D3909 01/22/14
G6850.08.07-1 ASTM D3909 08/13/07
G30250.02.10-3-R1 ASTM D3909 11/26/12
NOA No.: 13-1022.15
CML"AAMDAD EQOUNTY Expiration Date: 11/04/18
APPROVEMD Approval Date: 11/06/14
Page 5 of 16
Membrane Type: BUR
Deck Type 1: Wood,Non-insulated
Deck Descriptions 19/32" or greater plywood or wood plank decks
System Type E: Base sheet mechanically fastened.
All General and System Limitations shall apply.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield®Fire Resistant Roof Deck Protection or
(optional) SecurockTM Gypsum Fiber Roof Board.
Base sheet: GAFGLAS®#80 UltimaTm Base Sheet, Stratavent°Eliminator
TM Nailable Venting Base
Sheet, Ruberoid°20, Ruberoid° SBS Heat-Weld TM Smooth or Ruberoid® SBS Heat-Weld TM
25 base sheet mechanically fastened to deck as described below;
Fastening Options: GAFGLAS' Ply 4, GAFGLAS°F1exPlyTM 6, GAFGLAS`''#75 Base Sheet or any of above
base sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field.
(Maximum Design Pressure—45 psf. See General Limitation #7)
GAFGLAS®R Ply 4, GAFGLAS F1exP1yTM 6, GAFGLAS®R #75 Base Sheet or any of above
base sheets attached to deck with Drill-TecTM #12 Fastener or Drill-TecTM#14 and Drill-
Te cTM 3" Steel Plate, Drill-TecTM AccuTrac®Flat Plate or Drill-TecTM AccuTrac Recessed
Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12"o.c. in the field of the sheet.
(Maximum Design Pressure—45 psf. See General Limitation #7)
GAFGLAS Flex P1yTM 6, GAFGLAS`'#75 Base Sheet or any of above base sheets attached
to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c.
at the 4" lap staggered and in two rows 9" o.c. in the field.
(Maximum Design Pressure—52.5 psf. See General Limitation#7)
GAFGLAS°#80 UltimaTM Base Sheet, Ruberoid°20, Ruberoid®Mop Smooth, base sheet
attached to deck with approved P/4" annular ring shank nails and inverted 3" steel plate at a
fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of
9" o.c. in the center of the membrane.
(Maximum Design Pressure—60 psf. See General Limitation #7)
GAFGLAS#75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM
#l2 Fastener or Drill-TecTM #l4 Fastener and Drill-TecTM 3" Steel Plate, Drill-TecTM
AccuTrac'®Flat Plate or Drill-TecTM AccuTrac® Recessed Plate 12" o.c. in 4 rows. One row
is in the 2" side lap. The other rows are equally spaced approximately 9"o.c. in the field of
the sheet.
(Maximum Design Pressure—60 psf. See General Limitation #7)
Any of above Base sheets attached to deck approved annular ring shank nails and 3"
inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered
in two rows 9" in the field.
(Maximum Design Pressure—60 psf. See General Limitation #7)
NOA No.: 13-1022.15
Miaoane ouN nr Expiration Date: 11/04/18
R Approval Date: 11/06/14
Page 14 of 16
Fastening Options: GAFGLAS®#75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM
(Continued) #12 Fastener or Drill-TecTM#14 Fastener and Drill-TecTM 3" Steel Plate, Drill-TecTM
AccuTrac® Flat Plate or Drill-TecTM AccuTrac"�Recessed Plate 8"o.c. in 4 rows. One row
is in the 2" side lap. The other rows are equally spaced approximately 9''o.c. in the field of
the sheet.
i
(Maximum Design Pressure—75 psf. See General Limitation#7)
Ply Sheet: One or more plies of GAFGLAS"' Ply 4 or GAFGLAS°#80 Ultima Base' Sheet adhered in a
full mopping of approved asphalt applied within the EVT range and at a rate of 20-40
lbs./sq.
Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS®
EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mapping of
approved asphalt applied within the EVT range and at a rate of 20401bs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen
components must be applied according to manufacturer's application instructions.
All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq.
2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq.
Maximum Design
Pressure: See Fastening Options
I
11
i
NOA No.: 13-1022.15
MIAMI-DADE COUNTYM Expiration Date: 11/04/18
Approval Date: 11/06/14
age 15 of 16
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS°Ply 4 and GAFGLASO'Flex PIyT" 6 when used as a mechanically fastened
base or anchor sheet.
2. Minimum 1/4"DlensDeckTm Roof Board or 1/2"Type X gypsum board is acceptable to be installed directly over the
wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may;be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4'(maximum.
4. An overlay ano/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6"break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of]either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be
limited to a in design pressure of-45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F')value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall�!be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS,117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within
this NOA, General Limitation #9 will not be applicable.)
8. All attachmen and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum'!designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field,
perimeters, and corners).Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones(i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA,General Limitation#7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3'of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 13-1022.15
QMMIAMMADOMOUNTY Expiration Date: 11/04/18
''� Approval Date: 11/06/14
Page 16 of 16
TOFU-81306 -Roofing Systems Wage 2 of 2
Structural cement fiber building units are considered suitable to be Included as a deck in the following Class A,B or C systems listed over C-15/32
or NC.
The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating.The use of 1/2-In, minimum thick
gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks.
The use of polystyrene Insulation board between minimum 3,c-In.thick perlite board and deck with rosin paper(perlite/rosin
paper/polystyrene/perlite)is a suitable alternate for polyisocyanurate board in the following Class A,B or C systems,
"EnergyGuard" RA"or"Tapered EnergyGuardTM RA"or"EnergyGuard1I Composite RA" may be substituted for any Atlas Roofing Corp.
polyisocyanurate insulation in any of the following Classifications,
Trumbull "Perms Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt".
"GAFGLASCp)#80 Premium Base Sheet"may be used in any of the following systems,
"GAFGLASC) Flex Ply 6"and"Tri-Ply® Ultra-Flexible Ply 6"are suitable alternates to"GAFGLAS(&Ply 6".
"GAFTEMP Perrnalite Recover Board"may be used in lieu of any perlite insulation in any of the following NC:Classifications.
Unless otherwise Indicated,any of the"Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with"Fireshield MB"at 2'/2 to 3-gal/10o-
fC2.
"Ruberoide Dual Smooth"may be used as an alternate to"Ruberoid®Mop Smooth"or "Ruberoic4 20"or"Ruberoide 20 HT"'
"Ruberoid®Mop Smooth 1.5"may be used as an alternate to"Ruberoid®Mop Smooth"
Class A, B and C
Hot roofing asphalt,for use with organic and glass felts or modified bitumen membranes.
"Ruberoide Heat Weld"SBS roofing membrane may be used In lieu of"RuberoidO Mop"SBS products in any applicable Classification,
Class A
1. Deck: C-15/32 Incline: 3
Insulation(Optional):--One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
periite/polyisocyanurate composite or perlite/urethane composite or wood III ber/polyisocyanurate composite or pheno:ic,any thickness.
Ply Sheet: —Three or more plies Type GI or"GAFGLASO Ply 4"or"Tri-Plyp Ply 4"or"GAFGLASO Ply 6"hot mopped.
Surfacing: —Gravel,
2. Deck: C-15/32 Incline: 2
Insulation (Optional):--One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or urethane or
perlite/poiylsocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic,any thickness.
Ply Sheet:—Three or more plies Type G1 or"GAFGLASO Ply 4"or"Tri-Plye Ply 4"or"GAFGLASO Ply 6",
Cap Sheet; —One ply Type G3"GAFGLAS(D Mineral Surfaced Cap Sheet"or"Tri-Piye Mineral Surfaced Cap Sheet"or"GAFGLASe
EnergyCap"BUR Mineral Surfaced Cap Sheet."
3. Deck:NC Incline: 2
Insulation (Optional): --One or more layers perlite,wood fiber,glass fiber,polyisocyanurate, urethane,periite/polyisocyanurate
composite, periite/urethane composite, wood flber/polyisocyanurate composite,phenolic,2-in, maximum.
Ply Sheet: —Two or more plies Type GI "GAFGLASe Ply 4","Tri-Ply®Ply 4" or"GAFGLASe Ply 6".
Cap. -W One ply Type G3"GAFGLASe Mineral Surfaced Cap Sheet"or"Tri-Ply(&Mineral Surfaced Cap Sheet"or"GAFGLASO
/ e gyCap"' Mineral Surfaced Cap Sheet."
/4, Deck: C-15/32 Incline: I
SiivSSheet(Optional):--Red rosin paper, nailed to deck.
Insulation (Optional): --Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with
OMG Inc."OlyBond Fastening System"or any UL Classified Insulation adhesive.
Base Sheet:—One ply Type G2 "GAFGLAS®#75 Base Sheet"or"Tri-Ply®#75 Base Sheet"(may be nailed),
Ply Sheet: —One or more plies Type GI"GAFGLAS(&Ply 4"or"Trl-Ply@ Ply 4"or GAFGLASe Ply 6",
Cap Sheet: –=3rie ply Type G3"GAFGLASe Mineral Surfaced Cap Sheet"or"Tri-Plyp Mineral Surfaced Cap Sheet"or"GAFGLASe
EnergyCap" 507Mineral Surfaced Cap Sheet,"
Surfacing(Optional):—"TOPCOAT(D EaergyCoter""applied at a rate of 2-gal/100-ft2,
http://dai:abase.ul-com/egi-bin/XYV/template/LISEXT/l FRAME/showpage.h.tml?natf,e=TG... 9/9/2013
.s OR Miami Shores Village
.... ...� Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date: 3/20/15
10050 NE 2nd Ave
Miami Shores, FI 33138
Re: Owner's Name: Jules Raphael
Property Address:117 N.W. 94 Street Miami Shores, Fl 33150
Roofing Permit Number:
Dear Building Official:
I Jules Raphael certify that I am not required to retrofit the roof to wall connections of my
building because:
q The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC)or with the provisions
of 1994 edition of the South Florida Building Code(1994 SFBC)
SignreC/ Print Name
State of Florida
County of Dade
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this 0 d of_ /�(ti.t ryG� �O/J
------
MARYLOU HeRwrrwQ
Y . MY COMMISSION i FF 059092
AR
Notary Public, Sate of Florida at Large EXPIRES:October 10,2017
~ ltl Ski, Bonded Thru Notary Public underwriters
• When the just valuation of the structure for purpose of ad valorem taxation is equal to or more th 300,000.00,an e w ing s a 1994
SFBC.Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009