Loading...
RF-15-1349 (2) Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-236072 Permit Number: RF-6-15-1349 Scheduled Inspection Date: August 14, 2015 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: CAMEAU, RASHA AND PAUL Work Classification: Tile Job Address:266 NW 92 Street Miami Shores, FL Phone Number Parcel Number 1131010331270 Project: <NONE> Contractor: JUVAL CORPORATION Phone: (305)491-8438 Building Department Comments REPLACEMENT OF TILE ROOF WITH COLOR THUR Infractio Passed Comments BLENDED TERRACOTTA& RED BLEND INSPECTOR COMMENTS False I Co ryE!�rjts Passed l Failed � S Correction ❑ Needed Re-Inspection ❑ Fee No Additional Inspections can be scheduled until re-inspection fee is paid. August 13,2015 For Inspections please call: (305)762-4949 Page 11 of 29 ACB2 Engineering Inc. Testing & Engineering Services Certification of Authorization #8131 Roof Tile Uplift Test Report Tel: 954-245.8976; Fax: 954.301.7776 5230 NE 18 Avenue Fort Lauderdale, FL 33334 Attention: Miami Shores Village, Building Division, 10050 NE 2nd Avenue, Miami Shores, FL 33138 Client: Juva) Corp y Test Date: 7/8/2015 Permit# RF-6-15-1349 Property Address: 266 NW 92 Street, Miami Shores, FI Roof Pitch: Type of Tile: Roof Area: 3 in 12 Eagle Roof Tile 32.00 squares Tile Attachment Method: Two Component Polyurethane Foam Adhesive-Poly Pro H 160 Field Instrument : IMADA Force Gauge 0-100 Serial number:243454 Test Location Total Number of Tests Field Uplift Pull Test Test results Perimeter Area: 14.00 sq 14 As per FBC 2010 Passed Field Area: 18.00 sq 18 As per FBC 2010 Passed No.of Corner: 14 14 As per FBC 2010 Passed Ridge Areas: 120 pcs 10 As per FBC 2010 Passed Important: These laboratory results can change due to future weather impacts and/or unavoidable roof traffic.Therefore,this report represents the TAS 106 results at the time of the test. Please see attached a Roof Sketch for this project. Cordia4ilering ACB2 EInc. (NOA 09-1005.01) Antonido, PE Fla. Reg. No: 36466 ACB2 Engineering Inc. A Engineering and Laboratory Services 5230 NE 18'hAvenue Fort Lauderdale, Florida 33334 Phone: (954) 245-8976 Fax: (954) 301-7* 776 T- I \ I T t ' fi AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. Miami shores Building Official To: 10050 NE 2nd Ave miami Shores, FL 33138 Re: Owner's Name Rasha Cameau Property Address 266 NW 92 Street Roofing Permit Number �� �/ f I✓ l ✓,/ Dear Building Official: Ismael Ramos I certify that the roof decking attachment and fasteners have been strengthened and corrected and a secondary water barrier has been provided as required by the "Manual of Hurricane Mitiga 'on Retrofits for Existing Site-Built Single Family Structures" adopted by the Florida Building Co ission by Rule 9B-3.047 F.A.C. i Qualifyin g Signatu alifying Agent Ismael Ramos Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscribed before me this IS- day of J con c ,20 (SEAL) 0,0A Op;�,, ALFOVSO ESCORCIA =� Commission#EE 831693 My Commission Expires '' °„;;a•°' September 03, 2016 ✓ Personally known or Produced Identification OBD—ents and Scttiiip4,u I W y Docmnenbs StatisticsGraphs_2Vtoofing Affidavit Compliant-9 26 07Fihable.doe � k�►t�4 �sno"FS r,� Miami Shores Village3 ` PeXl7?#lkTYj Roof a� 10050 N.E.2nd Avenue NW ` ... �... ` � Work Classification.Tile Miami Shores, FL 33138-0000 - it Status APPROVED -moo Phone: (305)795-2204 \ f�rEs,w GORli3p'. u �1 Expiration: 12/08/2015 .. �3 Issue �F �,. .. Project Address Parcel Number Applicant 266 NW 92 Street 1131010331270 RASHA AND PAUL CAMEAU Miami Shores, FL Block: Lot: Owner Information Address Phone Cell RASHA AND PAUL CAMEAU 266 NW 92 Street (305)915-2982 MIAMI FL 33150-2231 266 NW 92 Street MIAMI FL 33150-2231 Contractor(s) Phone Cell Phone Valuation: $ 20,000.00 JUVAL CORPORATION (305)491-8438 _ _ _ .. � Total Sq Feet: 3000 Type of Work:Re Roof Available Inspections: Additional Info: REPLACEMENT OF TILE ROOF WITH COLOR Inspection Type: Classification:Residential Up Lift Report Scanning:4 Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof Cap Sheet Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Contractors Bond $500.00 Invoice# RF-6-15-55825 CCF $12.00 06/04/2015 Credit Card $50.00 $808.00 DBPR Fee $4.50 DCA Fee $4.50 06/11/2015 Credit Card $808.00 $0.00 Education Surcharge $4.00 Bond#:2747 Notary Fee $5.00 Permit Fee-New Roof $300.00 Scanning Fee $12.00 Technology Fee $16.00 Total: $858.00 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING,MECHANICAL,WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. Futhermore, I authorize the above-n;Z7L ontractor to do the work stated. June 11, 2015 Authorized Signature:Owner / Applicant Contractor / Agent Date Building Department Copy June 11,2015 1 V 7 Miami Shores Village JUN 0 2o15 Building Department By. 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel:(305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 2010 BUILDING Master Permit No-RIP �'3H— PERMIT APPLICATION sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP ��// ,,1 /� ��,,,,�,L CONTRACTOR DRAWINGS 106 ADDRESS: 2[a0 vI IN `7 ? hi�1 City: Miami Shores Countv: Miami Dade Zip: 33/5-0 Folio/Parcel#: Pi33 A?70 Is the Building Historically Designated:Yes NO Occupancy Type: 5AA Load: Construction Type: S. IQ Flood Zone: BFE: FFE: OWNER: Name(Fee Simple Titleholder): 9,640 6g4C Phone#: yiT Address: R66 Al, / W, f„2 s*� City: State: C/'t Zip: Tenant/Lessee Name: /✓jq Phone#: Email: A) CONTRACTOR:Company Name: /,�/�/7 (,B $��'l' ��y! Phone#: J� Address: ���� �J1 44), 64ket-e � L City: 4- /dState: Zip: Qualifier Name: �5 /9�� �Q/ Phone#: State Certification or Registration#:_6 CG 133aO 5 Certificate of Competency#: DESIGNER:Architect/Engineer: /'/9 Phone#: Address: I" City: State: ? Zip: Value of Work for this Permit: Square/Linear Footage of Work: Jia Type of Work: ❑ Addition ❑ Alteration ❑ New [Repair/Replace ❑ Demolition Description of Work: � j7L�►Gj �-, / /� (�/ ��o Specify color of color thru Submittal Fee$ S 0� Pern'1if Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ -r�' elk t Qe _ TOTAL FEE NOW DUE$ ' _ � f Bonding Company's Name(if applicable) f/�K Bonding Company's Address City State qa Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also,a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the ce of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature ,J��l Signature OWNER or AGENT CONTRACTOR The foregoing instrument was ackn9yvIedged before me this The foregoing instrument was acknowledged before me this day of 20 �s .by day off 7ww 20 Ir by who is hois personally known to -T!514a Rsc/rlOS who is personally known to me or who has produced r ' as me or who has produced F P. L. as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLI NOTARY PUBLIC: IsE r*` Sign: ' ' Myr i Sign: � s 2 Print. M F rint: �biM •2or�rs Seal: Seal: �p+"^w Notary Pudic St ete of Florida Joanna M Feliciano �j My Commluion FF 082753 TMt EKpire*01/1212018 APPROVED BY -1Plans Examiner Zoning Structural Review Clerk ♦5 ORES G sell Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 CONTRACTORS' REGISTRATION Fax: (305) 756.8972 IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. / COPY OF QUALIFIER'S STATE LICENCES B. PY OF LOCAL BUSINESS TAX RECEIPT C. �OPY OF LIABILITY INSURANCE* D. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICATE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. D. COPY OF LIABILITY INSURACE* E. COPY OF WORKERS COMPENSATION INSURANCE* (Workers Compensation EXEMPTION must have NOTICE TO OWNER form and Contractor Affidavit) *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. BUSINESS NAME: u BUSINESS ADDRESS: D Sok), CITY 1 em STATE IPZ ZIP BUSINESS PHONE: ( ) FAX NUMBER CELL PHONE ) �Q —� �$ QUALIFIER'S NAME: �sae� /�Ce/Yl C75 QUALIFIER'S LIC NUMBER:- C(-( RICK SCOT; GOVERNOR KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION ' CONSTRUCTIONINDUSTTRY LICENSING BOARD 9 ICCC1330038 The ROOFING CONTRACTOR Named below IS CERTIFIED_ Under the previsions of Chapter 489 FS, Expiration date: AUG 31, 2016 - RAMOS, ISMAEL. JUVAL CORPORATION ' 2040 SW 121COURT MIAMI FL 33'1755 s x ISSUED: 07/27/2014 DISPLAY AS REQUIRED BY LAW SEQ# L1407270001995 010426 1008,' Bltl""' T11111-11"Gimece l'77 747 Miami i u" n stat& of Florida -T>lIS IS BILL_ t34 IVI ?AY 33 /[y /Ky� a e 7\r1TnI\!�{ 6 Bt3iNatSB iwTMtll"gCATtCttrt' E�1~CEIPT tUta � E 2015 RENEWAL SEPTEMBE :z 46 SW 1 i 7334535 Must be disleya;f tat place�f usaness � Pursuant��Cbunt�Gide Napier ! Arty F 3EG.TYPEaF BUSI +iltr5$ OWNER PAYMENT, 111�tAL CSR t RATA N 196 SPECIALTY BUILDING CONTRAGTUIi 13v TRK Ctitwl.ECTt?A ;f CCC1330038 UVork�r } $75.00 07 25/2014 REDITCA Cf--14-029847 This tical Business Tint Receipt only confirms payment of the focal Business Tax. The Receipt is clot a licsns�a, p r e certificn ti ,trf a hof der s�queMcatiolns.to do business. Molder must complyr firth any govetnme�f or no trornmente to emtery law and requirements which,apply to the busine ## Thi'REGEIPT'1 d.a6ovo muitU displayed on all co�rrcial vehicles—Miami Da s, vde Sec 1114476 for"Mofe Information,visit Policy Number: PGLS003975-15 Date Entered: 6/3/2015 A�® CERTIFICATE OF LIABILITY INSURANCE D6/3/2015 DD/YYYY) THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MULTIPLE INSURANCE COVERAGES, INC. NAME: PHONE (305)559-5453 acNo: (305)559-5021 8772 S.W. STH STREET E-MAIL 1P ardo@multiP leic.com MIAMI, FL. 33174 ADDRESS: INSURERS)AFFORDING COVERAGE NAIC#___ INSURER A:INTERNATIONAL INSURANCE COMPANY OF ILIMNOVER INSURED JUVAL CORPORATION INSURER B: (CGL) INSURER C: 2040 SW 123 CT INSURER D: MIAMI, FL 33175 INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADDL SUER POLICY EFF POLICY EXP LTR INSD WVD POLICY NUMBER MM/DD/YYYY MM/DD/YYY LIMITS A COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ DAMAGE TORENTED CLAIMS-MADE x OCCUR PGLS003975-15 04/25/2015 4/25/2016 PREMISES Eaoccu«ence $ 100 000.00 MED EXP(Any one person) $ 5,000.00 PERSONAL 8 ADV INJURY $ 1,000,000.00 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 1,000,000.00 POLICY F—]jE O LOC PRODUCTS-COMP/OP AGG $ 1,000,000.00 OTHER: $ AUTOMOBILE LIABILITY COMBaccidentINED SINGLE LIMIT $ Ea _ ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS — ----- NON-OWNED PROPERTYDAMAGE $ HIRED AUTOS AUTOS Per accident $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB HCLAIMS-MADE AGGREGATE $ DED I I RETENTION$ $ WORKERS COMPENSATION PER OTH- AND EMPLOYERS'LIABILITY Y/N STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVEF7 N/A E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) HOME IMPROVEMENTS / REMODELING / ROOFING CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE BUILDING DEPT. SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 10050 NE 2ND AVE. ACCORDANCE WITH THE POLICY PROVISIONS. MIAMI SHORES, FL. 33138 F#(305)756-8972 AUTHORIZED REPRESENTATIVE LAURINDO R PARDO < �� ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD Producedusing Fortes Boss Plus software.www.ForrnsBoss.comlmpressivePublishing 800-208-1977 Date CERTIFICATE OF LIABILITY INSURANCE 4/17/2015 Producer: Plymouth Insurance Agency This Certificate is issued as a matter of information only and confers no 2739 U.S. Highway 19 N. rights upon the Certificate Holder. This Certificate does not amend,extend Holiday, FL 34691 or alter the coverage afforded by the policies below. (727) 938-5562 Insurers Affording Coverage NAIC# Insured: South East Personnel Leasing, Inc. &Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Insurer B: Holiday, FL 34691 Insurer C: Insurer D: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwithstanding any requirement,tens or condition of any contract or other document with respect to which this certificate may be issued or may pertain,the insurance afforded by the policies described herein is subject to all the terms,exclusions,and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR ADDL I Policy Effective Policy Expiration Limits LTR INSRD Type of Insurance Policy Number Date Date (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence Commercial General Liability Damage to rented premises(EA Claims Made 11 Occur occurrence) Med Exp Personal Adv Injury General aggregate limit applies per: General Aggregate Policy ❑Project ❑ LOC Products-Comp/Op Agg UTOMOBILE LIABILITY Combined Single Limit (EA Accident) Any Auto Bodily Injury All Owned Autos (Per Person) Scheduled Autos Hired Autos Bodily Injury Non-Owned Autos (Per Accident) Property Damage (Per Accident) EXCESSIUMBRELLA LIABILITY Each Occurrence Occur ❑Claims Made Aggregate Deductible A Workers Compensation and WC 71949 01/01/2015 01/01/2016 x WC Statu- OTH- Employers'Liability tory Limits I ER Any proprietor/partner/executive officer/member E.L.Each Accident $1,000,000 excluded? NO E.L.Disease-Ea Employee $1,000,000 If Yes,describe under special provisions below. E.L.Disease-Policy Limits $1,000,000 Other Lion Insurance Company is A.M.Best Company rated A-(Excellent). AMB#12616 Descriptions of Operations/Locations/Vehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 92-68-639 Coverage only applies to active employee(s)of South East Personnel Leasing,Inc.&Subsidiaries that are leased to the following"Client Company": ]uval Corporation dba Gables Roofing Coverage only applies to injuries incurred by South East Personnel Leasing,Inc.&Subsidiaries active employee(s),while working in:FL. Coverage does not apply to statutory employee(s)or independent contractor(s)of the Client Company or any other entity. A list of the active employee(s)leased to the Client Company can be obtained by faxing a request to(727)937-2138 or by calling(727)938-5562. Project Name: ISSUE 04-17-15(EP) Benin Date 7/23/2014 CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE Should any of the above described policies be cancelled before the expiration date thereof,the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left,but failure to BLDG.DEPT. do so shall impose no obligation or liability of any kind upon the insurer,its agents or representatives. 10050 NE 2ND AVE. MIAMI SHORES, FL 33138 !' , Section A ti r High Velocity Hurricane Zone Roofing Permit Application Form Section A(General Information) _RJEE Master Per Process No: f �TvED Contractor's Name: to.. val Corporation JUN 0 4 2015 Job Address: 266 NW 92 Street, Miami shores, FL 33150 BY• Roof Category ❑✓ Low Slope ❑ Mechanically Fastened Tile CMortar/Adhesive Set Tile ❑ Asphaltic Shingles Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: Roof Type ❑ New Roof Q Re-Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes ❑✓ No If yes,what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area ft') 0 Steep Sloped area (ft.2) 3000 Total (ft.z) 3000 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): 3 Corner Size(a' x a'): 3x3 36' 8' O Q F 40' I m w 51' 34' QCD W a 0:000 .. . m to. . /0. I ••. • cn o6o . .3!yo . • • 00: . •• .• . . • •• .. ... . . . ... . . Owner's Notification Form 07 z r MIAMI "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES--REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code,Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. 1.Aesthetics-workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as rt of the agreement between the owner and the contractor. 2.Renailing wood decks: When replacing roofing,the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Buil ing Code. (The roof deck is usually concealed prior to removing the existing roof system). C3.Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses,condominiums,etc.). In buildings with common roofs,the roofing contractor and/or own r should notify the occupants of adjacent units of roofing work to be performed. L 4.Exposed ceilings: Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore,roofing nail penetrations of the underside of the decking may not be acceptable.The owner provides the option of mai Mining this appearance. /V 5.Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roo,#W system is removed. Ponding conditions should be corrected. f�/ 6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with he requirements of: Chapter 15 and 16 herein and the Florida Building Code,Plumbing. 7.Ventilation:••Mostroof slrtict;res should have some ability to vent natural airflow through the int *or of the structural ass&Ll the 6u;lding itself). The existing amount of attic ventilation shall not be reduced. Exceptioq;•Axl Sp �cBs' •s!giaetl by a Florida-licensed engineer or registered architect to eliminate the attic venting,venting shall not required. G�• • Owner's/Agent's 4igna�lir Date: .. . : . . .. . . Contractor's Signahtre:e• Permit Number: Property Address: •• ..Wvna.k. xit . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . OFFICE OF PROPERTY Summary Report Generated On:4/17/2015 Property Information Folio: 11-3101-033-1270 Property Address: 266 NW 92 ST RASHA C SORAY&H Owner PAUL E CAMEAU 266 NW 92 ST Mailing Address MIAMI SHORES,FL 33150-2231 Primary Zone 0800 SGL FAMILY-1701-1900 SQ 0101 RESIDENTIAL-SINGLE Primary Land Use FAMILY:1 UNIT Beds I Baths/Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,015 Sq.Ft Taxable Value Information Lot Size 19,375 Sq.Ft 2014 2013 2012 Year Built 11940 County Assessment Information Exemption Value $50,000 $50,000 $50,000 Year 2014 2013 2012 Taxable Value $202,779 5199,044 $194,882 Land Value $126,750 $84,750 $67,500 School Board Building Value $162,183 $163,268 $174,434 Exemption Value $25,000 $25,000 $25,000 XF Value $2,472 $2,504 $2,948 Taxable Value $227,779 $224,0441 $219,882 Market Value $291,405 $250,522 $244,882 City Assessed Value $252,779 $249,044 $244,882 Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $202,779 $199,044 $194,882 Benefits Information Regional Benefit Type 2014 2013 2012 Exemption Value $50,000 $50,000 $50,000 Save Our Homes Assessment $38,626 $1,478 Taxable Value $202,779 $199,044 $194,882 Cap Reduction Homestead Exemption $25,000 $25,000 $25,000 Sales Information Second Homestead Exemption $25,000 $25,000 $25,000 Previous Price OR Qualification Description Note:Not all benefits are applicable to all Taxable Values(i.e.County,School Sale Book-Page Board,City,Regional). 03/01/2004 $0 22336-0032 1 Qual by exam of deed 09/01/2003 $225,000 21654-3709 2008 and prior year sales;Qual by Short Legal Description exam of deed MIAMI SHORES SEC 6 PB 10-39 11/01/1996 $0 17462-2705 Qual by exam of deed LOT 9&W1/2 LOT 8 BLK 136 2008 and prior year sales;Qual by LOT SIZE 75.000 X 125 12/01/1989 $52,000 14379-1663 exam of deed OR 17462-2705 1196 4 COC 22336-0032 22845-2547 0304 4 The Office of the Property Appraiser is continually editing and updating the tax roll.This website may not reflect the most current information on record.The Property Appraiser and Miami-Dade County assumes no liability,see full disclaimer and User Agreement at http:/Avww.miamidade.gov/info/disclaimer.asp Version: •• ••• • • • • • •• • •• • • • • ••• • •• ••• •• • • • •• • • • • • • • • • • • • ••• • • • • • • •• • • • • • • • •• • • ••• • • • • ••• • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • OWNER'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FANIILY RESIDENTIAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Village of El Portal, building Official 500 NE 87th Street El Portal, FL 33138 Re: Owner's Name Rasha Cameau Property Address 266 NW 92 Street Roofing Permit Number Dear Building Official: I Rasha Cameau certify that I am not required to retrofit the roof to wall connections of my building because: LJ The just valuation for the structure for purposes of ad valorem taxation in less than $300,000.00. LJ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of the 1994 edition of the South Florida Building Code (1994 SFBC). �l�3hOz Signature of Property Owner Rasha Cameau Print Name STATE OF FLORIDA COUNTY OF MIAMI-DADE Sworn to and subscriri ed be re me this r"� , day of i20 (SEAL) ••: .. ... .. . . . .. Personal^nNfl ' r Produ&Aldehtifica&8a .. • 00 When the just valuation of the structure oses of ad valorem taxation is equal to or more than $300,000.00, tO the bbil'ditIg*4va9 not:co structed in compliance with the FBC nor with 1994 SFBC, and affidavit of�oQftQWali Cpnrictidn Hurricane Mitigation Retrofit must be provided. ••• 0 0 0 ••• 0 0 c: wand s«finp\�I\Myu�u\StatMmcr.pn+ZR�fine,femh,c®p„ 92607r1.m<.aa Tile Roof System MIAMMU* Miami-Dade County Building Department Electronic Application Section D Sloped System Description Tile Roof System "Delivering Excellence Every flay" Roof System Manufacturer: Eagle Roofing Notice of Acceptance Number(NOA): 11-0321.03 Minimum Design Wind Pressures,If Applicable(from RAS 127 or Calculations): P 1: -39.1 P 2: -68.1 P 3: -100.2 Maximum Design Wind Pressures,(From the NOA Specific system): 29.3 psf Fill in the specific roof assembly components.if a component is not required,insert not applicable(n/a)in the text box. Deck Type:1--5/8" Plywood-- Optional Insulation: NA Optional Nailable Substrate: NA Optional Nailable Substrate Attachment: Roof Slope: 4 "/12" NA Roof Mean Height: 10 ft. Basesheet Type: Method of Tile Attachment: 30#FELT D226 --Adhesive, 2 Small Paddy Tile Bond-- Fastener Type for Basesheet Attachment: Alternate Method of Tile Attachment per NOA: 1 1/4"GALV RS NAILS 2- 10d Galy RS nails Tile Underlayment(Cap Sheet)Type: TARCO PS200 Drip Edge Size&Gauge: --3"face 24 ga.-- Tile Underlayment Attachment Method: Drip Edge Material Type: --Galvinized Metal-- Self Adhered membrane :1 3/4'•Gaw AS•nails Tile Profile: Drip Edge Fast*er Typj: •• • . • • • . . • • •. Eagle Capistrano .. ... .. .. Hook Strip/Cleat gauge or weight: --n/a- . . . . • . . . . . . ••. • . . . . • . . . • •.. . • . .•. . ucuwu u c M(AMb01ADE Miami-Dade County Building Department Electronic Application REEN High Velocity Hurricane Zone Roofing Permit Application Form Del verhig Excellence Every Day" Section E(Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based tile systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values,for each area of the roof,then the tile attachment method is acceptable. P 1: -39.1 x x .277 = 10.83 _Mg: 6.88 =Mr1: 3.95 5 29.3 NOA Mf P 2: -68.1 x% .277 = 18.86 _Mg: 6.88 =Mr2: 11.98 s 29.3 NOA Mf P 3: -100.2 x% .277 = 27.76 _Mg: 6.88 =Mr3: 20.87 s 29.3 NOA Mf Method 3"Uplift Based Tile Calculations Per RAS 127" or Uplift based tile systems use Method 3.Compare the values for F'with the values for Fr. If the F'values are greater than or equal to the Fr values,for Bch area of the roof,then the tile attachment method is acceptable. 11: x I: = x w: _ -W: = x cos 0: =Fr1: s NOA F' 12: x I: = x w: _ -W: = x cos 0: = Fr2: s NOA F' 13: x I: = x w: _ -W: = x cos 0: = Fr3: s NOA F' Where to Obtain Information to complete tile calculations Where to Find Description Symbol Design Pressure P1 or P2 or P3 Table 1 RAS 127,or by an engineer analysis prepared,signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier T Product Approval(NOA) Restoring Moment due to Gravity Mg Product Approval(NOA) Attachment Resistance Mf• • Y �• Product Approval(NOA) • . Required Moment Resistances• •� ••'BVI; ; ;.; •. Calculated Minimum Attachment ResistaAte ••• ••F' • • •• Product Approval(NOA) Required Uplift Resistance • • Y . Fr • . • Calculated Y . • Average Tile Weight ••• • •SIV; ; • •; : : Product Approval(NOA) • • length I=ll Tile Dimensions w width Product Approval(NOA) • •• •• ••• ••• •• •• Ml®BADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT(BNC) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/buildin¢/ Eagle Roofing Products LLC 1575 East C.R.470 Suniterville,FL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County BNC-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (ht Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Capistrano Concrete Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been fled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION" }fi of this ei the VOA shall be provided to the user by the manufacturer or its distributors and shall be av%tlab1V b1ljsj4i44 at the job site at the request of the Building Official. . . . . . . This renews 145A 467:40001'.8.090 and consists of pages 1 through 7. 'The submitted documentation was reviewed by Alex Tigera. 000 0 •• ; ' ': NOA No.:11-0321.03 MIatHN®urtrY Expiration Date: 10/05/16 Approval Date: 05/12/11 . . . ..+ • Page 1 of 7 . . :.'.: .. .. . . 000 0 • ROOFING ASSEMBLY APPROVAL Category Roofing Sub Category: Roofing Tiles Material: Concrete 1.SCOPE: This approves a new roofing system using "Capistrano Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville,FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2.PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description Capistrano Concrete L= 17" TAS 112 High profile concrete roof tile. For direct Tile W= 12 t/4" deck or battened nail-on applications. Thickness='/z" Trim Pieces I=varies TAS 112 Accessory trim,clay roof pieces for use at w=varies hips,rakes,ridges and valley varying thickness terminations. Manufactured for each tile profile. • . • . • . . • • . •• • • • • • • • •• • • • '• NOA No.:11-0321.03 MIAMI•DAD@ COUNTY • • • •• Expiration Date:10/05/16 �Fjmggrjuj Approval Date: 05/12/11 "• "' Page 2 of 7 . . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies ERPF-001-02-02 TAS-112 Aug.2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102& 102(A) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108(Nail-On) Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108(Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs. smooth shank nails The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering,Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering,Inc. TAS 101 (Mortar Set) The Center for Applied 25-7094-(3,6& 9) Static Uplift Testing Oct. 1994 Engineering, Inc. TAS 102 The Center for Applied 25-7120-(1 &2) Static Uplift Testing Nov. 1994 Engineering,Inc. TAS 102 The Center for Applied 25-7183-(3 &4) Static Uplift Testing Feb. 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7214-(3,4,&7) Static Uplift Testing March, 1995 Engineering,Inc. TAS 102 The Center for Applied 25-7804-4 Static Uplift Testing Sep. 1996 Engineering,Inc. TAS 102 Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services TAS 101 Celotex Corporation 520191-2-1 Static Uplift Testing March 1999 Testing Services TAS 101 Walker Engineering,Inc. Calculations Aerodynamic Multiplier Sep.2006 .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . : NDA No.:l 1-0321.03 MIAMI-DADE c-� • Expiration Date: 10/05/16 Approval Date: 05/12/11 ••• "' Page 3 of 7 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may required,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix`A'.Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Capistrano Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight(W)and Dimensions(I x w) Tile Profile Weight-W(Ibf) Length-1(ft) Width-w(ft) ,Capistrano Concrete Tile 10 1.417 1.04 Table 2: Aerodynamic Multipliers-A ft Tile A(ft ) A(ft ) Profile Batten Application__ Dire Deck A !cation Capistrano Concrete Tile 0.300 0.27 Table 3: Restoring M ments due to Gravit -M (ft-tq Tile 3":12" 4":1 5":12" 6":12 Greater than Profile 7":12" Capistrano Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Concrete Tile Deck Deck Deck Deck Deck 6.68 6.99 6.57 6.88 6.44 6.73 6.28 6.56 6.10 6.38 . .. . . . . ... . .. ... .. . . . .. ... . . . . . . . . . . . . . . . . • ' 0 •• 0 NOA No.:11-0321.03 MIAMI�DADECOUNW • �• • Expiration Date: 10/05/16 Approval Date: 05/12/11 ••• ••• Page 4of7 . . . . . . . . . . . .. .. . . • •• .. . ... . . . ... . . z • Table 4: Attachment Resistance Expressed as a Moment-Mi(ft-Ibf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 16132" plywood) (min. 19/32" plywood) Capistrano 2-10d Ring Shank Nails 28.6 41.2 19.4 Concrete 1-10d Smooth or Screw 5.1 6.8 2.8 Tile Shank Nail 2-10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1 #8 Screw 20.7 20.7 18.1 2#8 Screw 43.2 43.2 29.8 1-10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1-10d Smooth or Screw 29.3 29.3 24.0 Shank Nail Eave Clip) 2-10d Smooth or Screw 27.6 27.6 38.6 Shank Nails Field Clip) 2-10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) 2-10d Ring Shank Nails 33.1 48.1 45.2 1. Installation with a 4"tile headlap and fasterners are located a min. of 2W from head Table 5: Attachment Resistance Expressed as a Moment f(ft- for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Capistrano Concrete Tile Adhesive 29.3 k12 See manufactures com onent a roval for installation re uirements.Flexible Products Company TileBond Average weight per patty 10.7 gra . Pol foam Product, Inc.Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment-Mf(ft-Ibf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Capistrano Concrete Tile Polyfoam Pol Pro's"' 66.5 Pol foam Pol Prom 38.7 3 Large paddy placement of 63 rams of Pol Pro7"" 4 Medium paddy placement of 24 rams of Pol Pro7m. Table 7: Attachment Resistance Expressed as a Moment- Mf(ft-Ibf) for Mortar Set Systems Tile Tile Attachment Profit •• ••• ••. ; Application Resistance Capistrano ConcretcFTiie .; %: eMortarSef 24.5 . . .. ... .. . . . .. 6 Tile-Tito Roof Tile Mortar. ... .. . . . . . . . . . . . ... . . . . . . •' • " ' NOA No.:11-0321.03 MIAMI•DADE•UNTY • • Expiration Date: 10/05/16 Approval Date: 05/12/11 ... ... Page 5 of 7 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below),or following statement: "Miami-Dade County Product Control Approved". EA FL ORIDA CAPISTRANO CONCRETE ROOF TILE LABEL,SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building pen-nit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. .. ... . . . . . .. .. ... .. . . . .. . . . . . . . . . . ••• NOA No.:11-0321.03 . . . . . . . .. . . MU1Mi•QADE COUN •• • ••• ••• ••• Expiration Date: 10/05/16 Approval Date: 05/12/11 ••• ••• Page 6of7 . . . . . . . . . • . .. .. . . . .. .. ... . . . ... . . PROFILE DRAWING r t. CAPISTRANO CONCRETE ROOF TILE END OF THIS ACCEPTANCE . . . . . . . . .. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. NOA No.:11-0321.03 MADE COu •• Expiration Date: 10/05/16 r Approval Date: 05/12/11 ... ..• Page 7 of 7 . . . . . . . . . . 0% .. .. . . . .. .. . . . ... . . MIAMI-DADE MIAMI-DADE COUNTY i PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/eeonomv Tarco Specialty Products, Inc. One Information Way, Suite 225 Little Rock,AR 72202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tarco Roofing Membranes and Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entireq. .. ... . . . . .. INSPECTION: A copy of hall be provided to the user by the manufacturer or its distributors and shall t"AvaiAbto.!6r i.risr;cdion.at the job site at the request of the Building Official. This NOA revises NOA No. 11-0912.04 and consists of pages 1 through 16. The submitted docuVVt1Vbn was reytgwed^Jpf&e L. Acebo. . . ... . . . . . . NOA No.: 12-0420.02 ••• "` Expiration Date: 01/25/17 MIAMI•DADE COUNTY • • • • • • • ' • Approval Date: 10/03/13 . .. .. . . . .. ... ... Page 1 of 16 ROOFING COMPONENT APPROVAL Cateeory' Roofing Sub-Cate2ory: Underlayment Material: Asphalt, SBS, Polyester SCOPE: This acceptance is for Tarco Roofing Membrane and Underlayments, for use with approved prepared roof assemblies where the applicable TAS/ASTM specific underlayment is specified and installed with prescribed approved adhesives, fasteners and fastener densities,as described in this Notice of Acceptance; designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone of the Florida Building Code. PRODUCTS DESCRIPTION: Product Dimensions Test Specification Product Description 30#ASTM 3' x 72"rolls ASTM D226 Type I1 Asphalt saturated felt underlayment Specification Felt Manufacturing Location#1 & #2 EasyLay 3' x 133' 4" ASTM D226 Type II Sheet material comprising a polyester Manufacturing rolls substrate coated with bituminous coating Location#2 for use as an underlayment in roofing applications. Designed as a shingle and metal roofing underlayment and for use in tile roofing assemblies when used with an approved TAS 103 tile underlayment cap sheet. Fiberglass Mineral 3' x 36'rolls ASTM D3909 Mineral surfaced glass fiber reinforced, Surfaced Roll asphalt coated roll roofing for hot mop Roofing or cold process application. Manufacturing Location#1 ASTM Organic 3' x 36'rolls ASTM D6380 Asphalt saturated granular surfaced felt Tile Underlayment Type II underlayment for hot mop application. Manufacturing Location#1 EasyMop SBS 3' x 36'rolls TAS 104 Granular surfaced polyester reinforced, Manufacturing SBS modified bituminous membrane for Location#1 hot mop or cold process application. .., .. Designed as a tile roofing underlayment. . . . . . . . . . . NOA No.: 12-0420.02 ••• • ' ' ' '•' Expiration Date: 01/25/17 MIAM4DADE COUNTY • • • ' • • • • • : :': : : . Approval Date: 10/03/13 .:. :� �: �•� •�• �� Page 2 of 16 Product Dimensions Test Specification Product Description Fast90 3' x 36' rolls TAS 103 Granular surfaced, asphalt-impregnated Manufacturing ASTM D249 organic felt reinforced,bituminous sheet Location#1 ASTM D6380 material with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a tile roofing underlayment. PS200HT ' x 66'8"rolls TAS 103 Fabric surfaced, fiberglass reinforced, Manufacturing ASTM D1970 SBS modified bituminous sheet material Location#1 &#2 with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a shingle,tile and metal roofing underlayment. PS200"u 3' x 66'8"rolls ASTM D1970 Film surfaced, fiberglass reinforced, Manufacturing SBS modified bituminous sheet material Location#1 &#2 with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as a metal and shingle roofing underlayment. MS300 3' x 66'8"rolls ASTM D1970 Fine granular surfaced,fiberglass Manufacturing 3' x 33'4"rolls reinforced,bituminous sheet material Location#1 &#2 with a self-adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle roofing underlayment. SS400 3' x 66'8"rolls ASTM D1970 Smooth surfaced, fiberglass reinforced, Manufacturing 3' x 33'4"rolls bituminous sheet material with a self- Location#1 &#2 adhesive bottom layer,for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield, and a shingle and metal roofing underlayment. NR500HT 3' x 66'8"rolls ASTM D1970 Film surfaced,non-reinforced, Manufacturing bituminous sheet material with a self- Location#3 adhesive bottom layer, for use as an underlayment in sloped roof assemblies. Designed as an ice and water shield,and .. ... . . . . . .. a shingle and metal roofing . underlayment. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . NOA No.: 12-0420.02 ••• . • • • s•• • • MIAtti•ou4ne couNExpiration Date: 01/25/17 ► ; • ;•; s ; Approval Date: 10/03/13 " • ' ' •• •• Page 3 of 16 ••• • • • ••• • • MANUFACTURING LOCATIONS: 1. Greencastle,PA 2. Belton, TX 3. Coshocton, OH EVIDENCE SUBMITTED: Test Aeency Test Identifier Test Name/Report Date Atlantic&Carribean Roof ACRC06-013 TAS 103 06/14/06 Consulting,LLC PRI Asphalt Technologies TOT-003-02-01 ASTM D226 Type II 08/22/02 TOT-029-02-01 TAS 110, ASTM D249 &D 6380 07/05/05 TOT-030-02-01 TAS 110, ASTM D249&D 6380 07/05/05 TOT-041-02-01 TAS 110,ASTM D226 Type II 05/24/06 TOT-042-02-01 ASTM D4798 &ASTM G155 05/22/07 Trinity ERD T3580.10.06-2 TAS 103 10/26/06 T3580.10.06 TAS 103,ASTM D6380 10/12/06 T30160.08.09-R1 ASTM D1970 10/12/10 T10550.07.08 ASTM D4798 &ASTM D1970 07/30/08 T32530.08.10 ASTM D1970 08/17/10 T33190.08.10 TAS 103 08/06/10 T43930.09.13-R2 TAS 104 09/11/13 T40790.04.12 ASTM D6380 04/06/12 T40780.04.12 ASTM D3909 04/06/12 T37610.07.11 TAS 114-D 07/29/11 IRT-Arcon IRT07-0006 ASTM D1970 07/11/07 IRT 07-0036 ASTM D1970 02/22/08 IRT08-0002 ASTM D1970 02/22/08 GENERAL LIMITATIONS—30#ASTM SPECIFICATION FELT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. 30#ASTM Specification Felt may be used with any approved roof covering Notice of Acceptance listing ASTM D226 Type II felt as a component part of an assembly in the Notice of Acceptance. 4. All products lisIdd 118freip $haJI batela gdAlity assurance audit in accordance with the Florida Building Code and Rale WV of W Florida Administrative Code. .. ... .. . . . .. ... . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . =TY NOA No.: 12-0420.02 MIAMI•DADEC ; ; ;.; ; ; ; Expiration Date: 01/25/17 • Approval Date: 10/03/13 . .. .. . . . .. .. ••• • ••• Page 4of16 INSTALLATION REQUIREMENTS—30#ASTM SPECIFICATION FELT: 1. 30#ASTM Specification Felt shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing 30#Felt. 3. During installation of 30#Felt, comply with Occupational Safety and Health Administration (OSHA) safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. 30#ASTM Specification Felt shall be installed with a minimum 4"end lap in a shingle layer fashion and fastened as required by applicable system assemblies NOA or FBC 1518.2. GENERAL LIMITATIONS- EASYLAY: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. EasyLay shall be applied to a clean and dry surface. 4• EasyLay shall not be torched or hot mopped to. Refer to manufacturer's published literature for additional information. 5. EasyLay shall not be used on slopes less than 2:12, unless the slope is acceptable to the weather resistant covering. In general, on slopes less than 4:12, a double layer of EasyLay is recommended. Double layer application is best achieved by using 19"side laps, making sure the side laps are `shingled in' to shed water. 6. When installing EasyLay,the roof system must include proper ventilation. 7. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of EasyLay with specific prepared roofing products. EasyLay may be used with any approved roof covering Notice of Acceptance listing ASTM D 226 Type H felt as a component part of an assembly in the Notice of Acceptance. 8. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 9. EasyLay shall not be left exposed for longer than 30 days after application. 10. The manufacturer reserves the right to change product exposure period at any time;not to exceed the preceding rh*aAftrZ t9me'limlta2ioAr . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . NOA No.: 12-0420.02 • •"MIAMI•DADE COUNTY Expiration Date: 01/25/17 • • • • • • • p • Approval Date: 10/03/13 . .. .. . . . .. .. ••• ••• Page 5of16 APPROVED ASSEMBLIES- EASYLAY: System E(1): Anchor sheet mechanically fastened to deck. Deck Type 1: Wood,Non-Insulated. Deck Description: Minimum 19/32"plywood or wood plank. Anchor/Base Sheet: One or more plies of EasyLay underlayment,with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows 12"o.c. in the field(for Anchor/Base sheet). Surfacing: Approved Roof Assemblies in lieu of FBC perscribed ASTM D 226 Type 11 felt. INSTALLATION REQUIREMENTS-EASYLAY: 1. EasyLay shall be installed in strict compliance with applicable Building Codes. 2 Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing EasyLay. 3 During installation, comply with Occupational Safety and Health Administration(OSHA)safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. EasyLay shall be acceptable for use with asphaltic shingles,wood shakes and shingles, quarry slate,tile and metal roofing assemblies. 5 Re-fasten any loose decking panels, and check for protruding nail heads prior to the application of EasyLay. 6. Place a full width piece of EasyLay,parallel to the eave(low)edge of the roof. 7. Unroll EasyLay 2 to 3 feet,with the lay lines facing up,and position the end of it to the edge of the eave and rake. 8. Install a few fasteners at the top,near the rake,and roll out the sheet to a manageable length. 9. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. 10. EasyLay shall be fastened with approved roofing nails and tin caps or approved cap nails,driven by hand or pneumatically, spaced 6"o.c. at all laps in the center of the seam area, and two staggered rows fastened 12"o.c. in the field of the sheet. 11. When installing nails,apply so that the head of the nail is flush with the EasyLay surface,without cutting into the EasyLay surface. 12. Fastening shall be done from the top to avoid walking or kneeling on unsecured sheet. 13. Continue on to the end of the substrate and fasten down. .. ... . . . . . .. 14. Align the nXt roll oven Aha pieoec�ing sheet so as to form a minimum 4"overlap. . .. . . . . ... . . . . . . . . .. ... .. . . . .. .. .. . . . . . . . . . .. . . . . . . ... . . . ... . . . . . .. . 000 . 000 NOA No.: 12-0420.02 WMIAMI-DADE MMOUNTY • •'• Expiration Date: 01/25/17 MIAMI•DADE COUNTY • • • • • • • • : . : : : : . Approval Date: 10/03/13 ... . . . ... . Page 6 of 16 15. Then install the just placed sheet,per instructions above. 16. The bottom of the second course of EasyLay shall lay on top of the first course so that any water will flow over the top of EasyLay. 17. Apply subsequent sheets in the same manner,with 4" side laps and 6"end laps over the preceding sheets. 18. When the top course is reached, lap about 6"of EasyLay over the ridge. 19. Install EasyLay a minimum of 6"up any vertical surfaces. 20. Stagger the end laps a minimum of 18"from the preceding course. 21. After installing EasyLay on the field of the roof, install drip edge at the eaves(if used). 22. When applying EasyLay in the valley, start at the low point and work to the high point,rolling the membrane from the center outward in each direction. Make sure there are no rips or large wrinkles in the EasyLay. 23. Before applying horizontal sections of EasyLay, install a vertical length of EasyLay down the center of the valley. 24. Several sections of EasyLay can be used,but be certain to overlap the higher sections several inches so any water will flow over the top of the sheet. 25. EasyLay underlayment in the valley areas must be covered with code prescribed metal or other approved valley lining material. 26. Apply a minimum 1/16"thick uniform layer of SBS trowel grade modified flashing cement to water proof areas of EasyLay where any cuts or tears have occurred. Seams or joints may require the application of an SBS trowel grade modified flashing cement. 27. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. GENERAL LIMITATIONS—FIBERGLASS MINERAL SURFACED ROLL ROOFING: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . NOA No.: 12-0420.02 • "' Expiration Date: 01/25/17 MIAMI•DADE COUNTYIF • • • • • • ' ' "• Approval Date: 10/03/13 000 0 0 0 000 0 0 Page 7of16 ( a INSTALLATION REQUIREMENTS—FIBERGLASS MINERAL SURFACED ROLL ROOFING: I Fiberglass Mineral Surfaced Roll Roofing may be used with any approved roof covering Notice of Acceptance listing Fiberglass Mineral Surfaced Roll Roofing as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D3909 roof membrane is specified and installed with prescribed approved asphalt, adhesives,fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing Fiberglass Mineral Surfaced Roll Roofing. 3. During installation of Fiberglass Mineral Surfaced Roll Roofing, comply with Occupational Safety and Health Administration(OSHA)safety standards; use common sense measures and adequate safety precautions to prevent accidents. GENERAL LIMITATIONS—ASTM ORGANIC TILE UNDERLAYMENT: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building codes. 3. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. INSTALLATION REQUIREMENTS—ASTM ORGANIC TILE UNDERLAYMENT: I ASTM Organic Tile Underlayment may be used with any approved roof covering Notice of Acceptance listing ASTM Organic Tile Underlayment as a component part of an assembly in the Notice of Acceptance or wherever a ASTM D6380 roof membrane is specified and installed with prescribed approved asphalt, adhesives,fasteners and fastener densities per applicable FBC requirements. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing ASTM Organic Tile Underlayment. 3. During installation of ASTM Organic Tile Underlayment, comply with Occupational Safety and Health Administration(OSHA) safety standards; use common sense measures and adequate safety precautions to psemant acaidevts.. .+ 00 .. so* Soo ... 00 00 ... .. . . . . . . . .. . . NOA No.: 12-0420.02 •• • • MIAMI•DADE COUNTY •••• Expiration Date: 01/25/17 • • • • + •••I ;'; : Approval Date: 10/03/13 . •• •• . • . •• •• ... ... Page 8 of 16 C GENERAL LIMITATIONS—EASYMOP SBS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications.Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco EasyMop SBS shall not be installed when any form of moisture such as water,dew,rain, etc. is present on the substrate. 4. Tarco EasyMop SBS are to be applied to a smooth,clean and dry surface,with the deck free from irregularities. 5. Ensure roof has positive drainage prior to installation of Tarco EasyMop SBS. 6. Tarco EasyMop SBS shall not be applied over a pre-existing roof membrane or system. 7. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 8 All tiles shall be staged(two tiles perpendicular to slope, four tiles on top parallel to slope)as per manufacturer's requirements, not to exceed 6-high,to the standard maximum roof pitch of 5 :12 for flat tiles and 6 :12 for lugged tiles(See Tile Staging Method diagram below). At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the roof tile. Tile Staging Method . . . iza �_ :s, A•`•y fd _ate'.-.a�& �': .• w i Front View- Staged Tiles (Slope Side View- Staged Tiles (Slope J) 9. The manufacturer reserves the right to change the tile staging method at any time as well as the number of tiles stacked, not to exceed the preceding maximum number of tiles limitation. 10. Tarco EasyMop SBS shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. . .. . . . . ... . . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . NOA No.: 12-0420.02 PIAMIDALDeCouNn Expiration Date: 01/25/17 Approval Date: 10/03/13 ... . . . ... . . Page 9 of 16 t. + 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco EasyMop SBS may be used with any approved roof coverings Notice of Acceptance listing Tarco EasyMop SBS or TAS 104 standard as a component part of an assembly in the Notice of Acceptance. If Tarco EasyMop SBS or the TAS 104 standards are not listed, a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product,wind uplift resistance, and fire testing results. 12. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. APPROVED ASSEMBLIES—EASYMOP SBS: System E(1): Anchor sheet mechanically fastened to deck,membrane adhered with hot asphalt or approved adhesive. Deck Type 1: Wood,Non-Insulated. Deck Description: Minimum 19/32"plywood,wood plank. Anchor/Base Sheet: One or more plies of ASTM D226 Type H or ASTM D2626 with a minimum 4" wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows 12"o.c. in the field(for Anchor/Base sheet only). Membrane: EasyMop SBS applied to Anchor/Base Sheet with hot asphalt or with approved adhesive as specified in RAS 118, 119 or 120. (See#13 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . NOA No.: 12-0420.02 MIAMI-DADeCouNTY Expiration Date: 01/25/17 Approval Date: 10/03/13 0: Page 10 of 16 INSTALLATION REQUIREMENTS—EASYMOP SBS: 1. Tarco EasyMop SBS shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing EasyMop SBS. 3. During installation, comply with Occupational Safety and Health Administration(OSHA)safety standards;use common sense measures and adequate safety precautions to prevent accidents. 4. EasyMop SBS shall be an acceptable underlayment for mechanically fastened roof tile and adhered roof tile applications. 5. Re-fasten any loose decking panels,and check for protruding nail heads prior to the application of EasyMop SBS. 6. EasyMop SBS shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean, dry and free of any loose debris or moisture prior to the application of the EasyMop SBS. Refer to applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing,valleys, liner, drip edge and concrete deck substrate with ASTM D 41 primer. 9. Applicator may cut EasyMop SBS into sections for workability and allow to relax prior to application. 10. Place EasyMop SBS over metal drip edge in accordance with RAS 111. 11. Install the first course of EasyMop SBS parallel to the eave edge. 12. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 13. EasyMop SBS shall be back nailed along the head lap. The nails shall be, 11 gauge 11/4"approved ring shank type applied with a minimum of a 15/8"approved tin cap or approved capnail as required per the High Velocity Hurricane Zone(HVHZ) section of the FBC, at a minimum rate of 12"o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 14. Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 15. Vertical strapping of EasyMop SBS membranes is acceptable. .. ... . . . . . .. .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . NOA No.: 12-0420.02 MIAMI•DADE COUNTY Expiration Date: 01/25/17 . .. .. . . . .. .. Approval Date: 10/03/13 ••• • ••• Page 11 of 16 ENERAL LIMITATIONS—TARCO SELF-ADHERED UNDERLAYMENTS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Tarco self adhering underlayments shall be applied only when material interface temperatures are 400 F and rising. 4. Tarco self-adhered underlayments shall not be installed when any form of moisture such as water, dew,rain, etc. is present on the substrate. 5. Tarco self-adhered underlayments are to be applied to a smooth, clean and dry surface,with the deck free from irregularities. 6. Ensure roof has positive drainage prior to installation of Tarco self-adhered underlayments. 7. Tarco self-adhered underlayments shall not be applied over a pre-existing roof membrane or system. 8. After installation of Tarco self-adhered membranes,wait a minimum of 48 hours before roof loading of tiles. 9. Care should be taken during the loading procedure to keep foot traffic to a minimum and avoid dropping the roof covering directly on the underlayment. 10. All tiles shall be staged(two tiles perpendicular to slope, four tiles on top parallel to slope)as per manufacturer's requirements,not to exceed 6-high,to the standard maximum roof pitch of 6 :12 for flat tiles and 6 :12 for lugged tiles(See Tile Staging Method diagram below). At roof slopes greater than the above limitations,the use of loading battens or toe boards are required to load the roof tile. Tile StaEin2 Method �' ��-- ay i",'� �•�,, "�- a'umVoiWl inti lil�i`„h�� 111 IfYo-ri ��I� 'I r Front View- Staged Tiles (Slope Side View- Staged Tiles(Slope 1) toto 11. The manufactutr reseViSsQidrigh2 to diange the tile staging method at any time as well as the number of tiles:tacked? iso;to etcceed th; -preceding maximum number of tiles limitation. 0:• . . . . . . . . . ... .... . . . . . . ... . . . . . . . ■ NOA No.: 12-0420.02 MIAWDADE COUNTY "' 0:0 Expiration Date: 01/25/17 ••• ! . . 0 Approval Date: 10/03/13 • •i to • . • •• •• 060 • 0 0 000 0 0 Page 12 of 16 12. EasyLay,PS20e" MS300, SS400,and HT shall not be left exposed as a temporary roof for longer than 30 days after applicatio PS200HT all not be left exposed as a temporary roof for longer than 120 days after application. ast90 shall not be left exposed as a temporary roof for longer than 180 days after application. The manufacturer reserves the right to change product exposure period at any time; not to exceed the preceding maximum time limitations. 13. NR500HT is not recommended for extreme high temperature environments such as under copper or zinc metal roofing. 14. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of Tarco underlayments with specific prepared roofing products. Tarco self-adhered underlayments may be used with any approved roof coverings Notice of Acceptance listing Tarco self adhering underlayments or the ASTM standard which the self adhering underlayments meet as a component part of an assembly in the Notice of Acceptance. If Tarco self-adhered underlayments or the ASTM standards are not listed, a request may be made to the Authority Having Jurisdiction(AHJ)or the Miami-Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the product,wind uplift resistance, and fire testing results. 15. All products lised herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. *APPROVED ASSEMBLIES—TARCO SELF-ADHERED UNDERLAYMENTS System E(1): Anchor sheet mechanically fastened to deck,membrane adhered. Deck Type 1• wood,Non-Insulated. Deck Description: Minimum 19/32"plywood,wood plank. Anchor/Base Sheet: One or more plies of ASTM D226 Type 1I,ASTM D2626, or EasyLay underlayment,with a minimum 4"wide side lap and a minimum 8"wide end lap,mechanically fastened to deck. Fastening: Approved nails and tin caps 6"o.c.within lap and two equally spaced staggered rows 12"o.c. in the field(for Anchor/Base sheet only). Membrane: All Tarco self-adhered membranes applied to approved Anchor/Base Sheet. (See#15 in Installation Requirements for back nailing) Surfacing: Approved Roof Assemblies as specified below. .. ... . . . . . .. • •• • • • • ••• • •• ••• •• • • • •• • • • • • • • • • • • • ••• • • • • • • NOA No.: 12-0420.02 Expiration Date: 01/25/17 M[AM I•DAD E COUNTY • • • • • • ' ' • Approval Date: 10/03/13 . .. .. . . . .. .. ... ... Page 13 of 16 System F(1): Membrane self-adhered to concrete deck. Deck Type 3• Concrete,Non-Insulated. Deck Description: Structural concrete or concrete plank min. 2500 psi. Deck Preperation: The concrete deck shall be clean and dry and cured for a minimum of 28 days. Anchor/Base Sheet: None Fastening: Membrane shall be back nailed with approved concrete fasteners and 15/8" approved tin caps at a maximum spacing of 9"o.c. at the head laps and be covered by the preceding layer.No back nail fasteners or tin caps shall remain exposed. Membrane: Tarco PS200HT self-adhered membrane applied directly to concrete deck. (See Fastening above for back nailing) Surfacing: Approved Roof Assemblies as specified below. INSTALLATION REQUIREMENTS—TARCO SELF-ADHERED UNDERLAYMENTS: 1. Tarco self adhering underlayments shall be installed in strict compliance with applicable Building Codes. 2. Observe and comply with roofing practices and guidelines as outlined by the National Roofing Contractors Associations(NRCA)when installing Tarco self adhering underlayments. 3. During installation, comply with Occupational Safety and Health Administration(OSHA)safety standards; use common sense measures and adequate safety precautions to prevent accidents. 4. Fast90 and PS200HT shall be acceptable underlayments for mechanically fastened roof tile and adhered roof tile applications. MS300 and SS400 shall be acceptable underlayments for asphaltic shingles,wood shakes and shingles, and slate or simulated slate roof assemblies. PS20eu and NR500HT shall be acceptable underlayments for asphaltic shingles,wood shakes, shingles,and metal roof panel assemblies. 5. Re-fasten any loose decking panels, and check for protruding nail heads prior to the application of the Tarco self adhering underlayments. 6. Tarco self adhering underlayments shall not be adhered directly over any pre-existing roof membrane. 7. All approved substrates are to be clean,dry and free of any loose debris or moisture prior to the application of the Tarco self adhering underlayments. Refer applicable building codes prior to installation to verify acceptable substrates. 8. Prime all metal collars, flashing,valleys, liner,drip edge and concrete deck substrate with ASTM D 41 primer,water based acrylic or water based polymer modified primer. 9. Contractor mat but t$e urulerlayrpepts Wo sections for workability and allow to relax prior to application. • .. . 10. Place the underlaynv;ntswver•metal:drip edge in accordance with RAS 111. 11. Install the first course of underlayment parallel to the eave edge. 12. Apply the tC�cTerl$yment,.w&kirrp f$oril the kenter of the material continuously to the ends of the sheet(half oNhe;ength of thg sheetj";thie.eenter);taking care to avoid wrinkles and ridges. NOA No.: 12-0420.02 Mu�rn•aane MWExpirationDate: 01/25/17 ... • •. •• Approval Date: 10/03/13 ••• ••• Page 14 of 16 S • 13. Remove the underlayments release film rapidly in a continuous fashion. Ensure the bottom adhesive side of the membrane does not adhere to its self. In the event this transpires,separate the two layers immediately. After some time, it may become impossible to do so without damaging the material. 14. It is recommended that end laps be staggered a minimum of 18" from the preceding course. 15. Underlayments are to be back nailed along the head lap. The nails shall be, 11 gauge 11/4" approved ring shank type applied with a minimum of a 15/8"approved tin cap or approved capnail as required per the High Velocity Hurricane Zone(HVHZ) section of the FBC,at a minimum rate of 9"o.c. The head lap of the preceding layer of underlayment is to cover the area being back nailed. 16. Roll or broom the entire membrane surface paying special attention to all overlap areas"side laps, end laps,T joints"to ensure adhesion with acceptable substrates. A minimum of a 28 lb weighted roller may be used for steep slope applications. The use of a soft bristled push broom is acceptable on steeper slopes. The above mentioned procedures are necessary in order to apply uniform pressure and allow for contact of the membranes. 17. Apply 1/8"thick uniform layer of SBS trowel grade modified bitumen asphalt adhesive/flashing cement throughout the contact area of the 6"granule over granule and fabric over fabric end laps. Once the aforementioned procedure has been completed,the membrane must then be hand rolled in place in order to ensure contact of membrane and achieve a minimum of 1/8ffi"asphaltic bleed out in designated area. 18. Tarco self adhering underlayments shall be applied to protrusions, slope changes,valleys,curbs, and other roof top penetrations before any other sections of the roof. 19. When applying underlayments in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in each direction. 20. For ridge applications, center the underlayment and roll from the center outward in both directions. 21. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 22. All protrusions or drains shall be initially taped with a 6" piece of like kind membrane. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of like kind membrane shall be applied over the flashing detail. 23. Vertical strapping of Tarco self adhering membranes is acceptable. .. ... . . . . . .. •• ••• •• • • • •• *00•• • • • • • • • •• • • ... . . . . ... . . NOA No.: 12-0420.02 MIAMI•DADE CouNTY ;• ; Expiration Date: 01/25/17 • . Approval Date: 10/03/13 • •• •• • • • •• •• 000 0 • 0 ••• 0 Page 15 of 16 MANUFACTURER'S CONSIDERATIONS: 1. When using Fast90 and PS200HT in tile roofing applications,use of loading battens or toe boards on roof slopes greater than 6:12 and higher is recommended. When using EasyMop SBS in tile roofing applications,use of loading battens or toe boards on roof slopes greater than 5:12 for Flat Tiles and 6:12 for Lugged Tiles and higher is recommended. 2. Code body requirements supersede manufacturer's recommendations and installation guidelines. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of these materials. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,city, state and the following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY ...• _ END OF THIS ACCEPTANCE .. ... . . . . . .. . .. . . . . ... . . . ... . . . . . . .. . . . . . . . .. . . .. . . . • . • . . . . ... . . NOA No.: 12-0420.02 •DA ... MIAMDE COUNTY ; ; ; ;•; ; ; ; Expiration Date: 01/25/17 "'• Approval Date: 10/03/13 . .. .. . . . .. .. ••• ••• Page 16 of 16 MIAM MIAMI-DADE COUNTY is PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.$ov/economy The Dow Chemical Company 1605 Joseph Drive 200 Larkin Center Midland,MI 48674 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TILE BONDTM Roof Tile Adhesive LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire.NOA s hall be provided to the user by the manufacturer or its distributors and shall be available for inspection at tje j9j,1t�ajtl�request of the Building Official. . •• • • • • :0: .• . This revises NOA# 11-061693 antltorMsts•of 1Sage!f I through 9. The submitted documentation was reviewed by Alex Tigera. 00. ... 0 06 • •• 0 0 • • NOA No.: 14-0820.08 MIAMI•DAD "• ' ' • ECOU� �4 Expiration Date: 08/23/16 ...• 1 Approval Date: 09/04/14 ... . .' Page 1 of 9 . . . . . . . . . . . •• •• 00 • •• .. ... . . . ... . . f ROOFING COMPONENT APPROVAL Category: Roofing Sub Category: Roof Tile Adhesive Material: Polyurethane SCOPE: This approves TILE BONDTM Roof Tile Adhesive as manufactured by The Dow Chemical Company as described in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code,do not exceed the design pressure values; as obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using TILE BONDTM Roof Tile Adhesive. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications TILE BONDTM Roof Tile N/A TAS 101 Single component polyurethane foam roof tile Adhesive adhesive PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of TILE BOND roof tile adhesive. MANUFACTURING LOCATION: 1. Wilmington, IL. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.83 lbs./ft.3 Compressive Strength ASTM D 1621 14.31 psi Tensile Strength ASTM D 1623 31.2 lbf @ 180°F, 65%RH for 120 days, concrete to concrete Water Absorption ASTM D 2842 2.21%absorbed by Volume Moisture Vapor Transmission ASTM E 96 3.00 Perm/Inch Dimensional Stability ASTM D 2126 -0.47%Volume Change @-40°C.,2 weeks -4.05%Volume Change @70°C., 100%Humidity, 2 weeks Closed Cell Content ASTM D 2856 86.3% Note: The physical properties listed above are presented as typical average values as determined by accepted AST& fest metkbds: and•are subject to normal manufacturing variation . .. . . . . ... . . •. .•• . . . . . . . . . .. . . . .. . . . • • NOA No.: 14-0820.08 MIAMI•DADE COUNTY ••..• •. Expiration Date: 08/23/16 • Approval Date: 09/04/14 ••• ••• Page 2of 9 • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • t EVIDENCE SUBMITTED: Test Aeency Test Identifier Test Name/Report Date Center for Applied 25-7512-1 TAS 101 01/25/96 Engineering 25-7512-2 TAS 101 01/25/96 25-7512-3 TAS 101 01/25/96 25-77512-4 TAS 101 01/25/96 25-7781 Physical Properties Testing 11/07/96 257794-2 SSTD 11-93 10/03/96 South Research Institute 01.8366-014 ASTM E108-95a February 1997 Walker Engineering,Inc. N/A Evaluation of Test on a Two-pad 12/16/97 System Celotex Corp. Testing 520111-1 TAS 101 12/28/98 Services 520111-2 TAS 101 12/28/98 520111-3 TAS 101 12/28/98 520111-4 TAS 101 12/28/98 520111-7 TAS 101 12/28/98 520111-8 TAS 101 12/28/98 520111-12 TAS 101 12/28/98 520135-3 TAS 101 02/01/99 520135-4 TAS 101 02/01/99 520135-5 TAS 101 02/01/99 IBA Consultants Inc. 4848-8 TAS 101 05/19/08 4848-7 TAS 101 05/19/08 4848-6 TAS 101 05/19/08 4848-5 TAS 101 05/19/08 4848-4 TAS 101 05/19/08 4848-3 TAS 101 05/19/08 4848-2 TAS 101 05/19/08 4848-1 TAS 101 05/19/08 Trinity ERD D9840.09.09 TAS 110 09/17/09 .. ... . . . . . .. .. . . .. . . . . ... . 0.0 . . . 00 .. . . . . . . . . . . . . . ... . . . . . . • •00 •0 NOA No.: 14-0820.08 MIAMtiDADE COUNTY ••• • • • 000 • • ... i Expiration Date: 08/23/16 Approval Date: 09/04/14 OV Page 3 of 9 . . . . . . . :0: . . . . . .. .. . . . .. .. ... . . . ... . . LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. TILE BOND Roof Tile Adhesive can be used with flat, low,medium and high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of TILE BOND Roof Tile Adhesive roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F W 2 F'= MS 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION: 1. TILE BOND Roof Tile Adhesive may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of TILE BOND Roof Tile Adhesive. 2. TILE BOND Roof Tile Adhesive shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of TILE BOND Roof Tile Adhesive shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. TILE BOND Roof Tile Adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120,and The Dow Chemical Company TILE BOND Roof Tile Adhesive Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator'approved and licensed by The Dow Chemical Company. 5. Pressure treated wood filler block shall be required on all eave course of all tile profiles, except on two piece barrel tile 6. Tiles must be adhered in freshly applied adhesive.Tile must be set within 4 minutes after TILE BONDTM Roof Tile Adhesive has been dispensed. 7. TILE BOND TM Roof Tile Adhesive placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE Tile Placement Minimum patty Weight Contact Area Profile Detail per tile(grams) (Square inches) Flat/Low Profile #1 11.1 19.5 Medium Profile .#2 .•• 11.0 19.5 High Profile(Head) # ••• 22.0 39 High Profile(Nose) ••• •• •• 11.0 19.5 Two Piece Barrel #4 11.6 20 . . . . . . . . . . % : ' ' NOA No.: 14-0820.08 MIAMI-oane COUNTY ••• Expiration Date: 08/23/16 lymj Approval Date: 09/04/14 ••• • • ••• • Page 4of 9 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . a � LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. MIAMI•DADE COUNTY ,...• 1 BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. . . . . . . . .. . . .. . . NOA No.: 14-0820.08 MIAMPI)ADE COUNTY ••• • • • •• • Expiration Date: 08/23/16 Approval Date: 09/04/14 ••• ••• Page 5of 9 . . . . . . . . . . . .. .. . . . .. .. ... . . . ... . . 1 v ADHESIVE PLACEMNT DETAIL i LOW (FLAT) PROFILE DETAIL#1 .. ... . . . . . .. . .. . . . . ... . .. ... .. . . . .. . . . . . . . . . . . . ... . . . . . . .. . . . . . . .. . . % . . . . . NOA No.: 14-0820.08 MALMMADE COUNTY ••• • • • •' ' Expiration Date: 08/23/16 Approval Date: 09/04/14 ••• • ••• Page 6of 9 . .. .. . . . .. .. ... . . . ... . . MEDIUM PROFILE DETAIL#2 •. • • • NOA No.: 14-0820.08 CMIAMI•DADE COUNTY ••• • •• Expiration Date: 08/23/16 • Approval Date: 09/04/14 ••• • ••• Page 7 of 9 HIGH PROFILE DETAIL##3 •. • . . .. . . . . ... . • . . . • .. ... .. . . . .. •. . . . . . . . . . .00 . . :. : : : : : : NOA No.: 14-0820.08 MIAMI•DADE COUNTY 00* • • • •• ' Expiration Date: 08/23/16 • Approval Date: 09/04/14 •:• ; ; ; ; .:• ; Page 8 of 9 • • . . .•. .• . • . . . . . . . BARREL PROFILE DETAIL#4 END OF THIS ACCEPTANCE . .. ... . . . . . .. . .. . . . . ... . • • • • • • • • • • •• • • • • • • • •• • • .. • • . NOA No.: 14-0820.08 Mui•�we couNnr ••` ' Expiration Date: 08/23/16 Approval Date: 09/04/14 •�• • • • • ••• • • Page 9 of 9 • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • •