Loading...
MC-15-1503 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-237156 Permit Number: MC-6-15-1503 Scheduled Inspection Date: July 08, 2015 Permit Type: Mechanical- Commercial Inspector: Perez;JanPierre Inspection Type: C-1 Owner: , BARRY UNIVERSITY Work Classification: Addition/Alteration Job Address: 11300 NE 2 Avenue Weber Hall Miami Shores, FL 33138-0000 Phone Number v Parcel Number 1121360010160-13 Project: BARRY UNIVERSITY Contractor: THERMAL CONCEPTS INC Phone: 954-472-4465 Building Department Comments REPLACE CONDENSATE DRAINS ON 8 AC FAN COILS Infractio Passed Comments RUN TO NEW FRENCH DRAIN INSPECTOR COMMENTS False A i Ins Pas 47V { Correction Needed Re-Inspection a Fee I No Additional Inspections can be scheduled until re-inspection fee is paid. s July 07,2015 For inspec 011,11 M `SgOREs h` Miami Shores Village „ A Re►rr�I � �h��l"C�xrt�!~�al 10050 N.E.2nd Avenue NE fp /O �ctGit(31A €i (An M Miami Shores,FL 33138-0000 ry�N � Phone: (305)7952204 ,� 8 Expiration: 12!20/2015 Project Address Parcel Number Applicant 11300 NE 2 Avenue Number: Weber Hall 1121360010160-13 BARRY UNIVERSITY INC Miami Shores, FL 33138-0000 Block: Lot: Owner Information Address Phone Cell BARRY UNIVERSITY INC 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 11300 NE 2 Avenue MIAMI SHORES FL 33161-6628 Contractor(s) Phone Cell Phone Valuation: $ 10,950.00 THERMAL CONCEPTS INC 954-472-4465 Total Sq Feet: 68 Tons: Available Inspections: Additional Info:REPLACE CONDENSATE DRAINS ON 8 AC F Inspection Type: Classification:Commercial Ventilation Approved:In Review Final Comments: Date Approved: : In Review Rough Date Denied: Type of Work: Rough Duct Scanning:3 Duct Detector Test Review Mechanical Fees Due Amount Pay Date Pay Type Amt Paid Amt Due CCF $6.60 Invoice# MC-6-15-56023 DBPR Fee $4.93 06/18/2015 Credit Card $50.00 $314.96 DCA Fee $4.93 Education Surcharge $2.20 06/23/2015 Credit Card $314.96 $0.00 Permit Fee $328.50 Scanning Fee $9.00 Technology Fee $8.80 Total: $364.96 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings,statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS, ROOFING and SWIMMING POOL work. OWNERS AFF VIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction ning. Futhermore, I authorize the above-named contractor to dQ the work stat June 23, 2015 Authorized Signa •Owner / Applicant / Contra r Agent Date Building Department Copy June 23,2015 1 � Sohl 1c3i Miami Shores Village Building Department JUN s 2015 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 I Tel:(305)795-2204 Fax:(305)756-8972 Aly - INSPECTION LINE PHONE NUMBER:(305)762-4949 - ° FBC 2011 3 BUILDING Master Permit NO. 1✓�C PERMIT APPLICATION Sub Permit No. ❑BUILDING L I ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [MECHANICAL E]PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 11300 NE 2nd Avenue - Webber Hall City: Miami Shores County: Miami Dade Zip: 33161 Folio/Parcel#: 11 2136 000 0050 Is the Building Historically Designated:Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name(Fee Simple Titleholder): Barry University Phone#: Address: 11300 NE 2nd Avenue City: Miami Shores State: FL Zip: 33161 Tenant/Lessee Name: Phone#: Email: CONTRACTOR:Company Name: Thermal Concepts, Inc. Phone#: 954 472-4465 Address: 2201 College Avenue City. Davie State: FL Zip: 33317 Qualifier Name: Lawrence D. Maurer Phone#: 954 472-4465 State Certification or Registration#: CAC039621 Certificate of Competency#: DESIGNER:Architect/Engineer: N/A Phone#: Address: City: State: Zip: Value of Work for this Permit: Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ^❑l New ■❑ Repair/Replace ❑ Demolition Description of Work: �1� �1.F�C 1� C-0 5- & Specify color of color thru tile: Submittal Fee$ ' Permit Fee$ � CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fee$ Structural Reviews$ Bond$ �( (:=Tl' TOTAL FEE NOW DUE$ 2W4 1 0 (Revised02/24/2014) Bonding Company's Name(if applicable) N/A Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) N/A Mortgage Lender's Address _ City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. J W Signature Signatures' OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this day of Un 20 15, by IU day of TLA n e— 20 15 by .7 ?"P ,who is personally known to Lawrence D. Maurer who is personally known to me or who has produced as me or who has produced himself as identification and who did take an oath. identification and who did take an oath. NOTARY PUBLIC: NOTA PUBLIC: TARDI, iA VA Si �� •• SSION'•.. ,1i Sign: � �. Z �� J �� s1r / ° 9cn�: — Print: r;,,, C.TRAP1118E Print: R ARIA' Sea I: S : — Seal: : 's MY COMM.EXP JULY 19,2018 5 y�; #�220337 s a COMMISSION 0 EE 217905 i 9'� �N �•��� ,,''�,��°", BONDEDTHfOUGHWESTERN$URETYCQ` APPROVED BY Ta��ans Examiner Zoning A-LStructural Review Clerk (Revised02/24/2014) Cs;THEHMAL C O N C E P T S HVAC Refrigeration DuCti00rk CAC039621 CSC046951 CGCA07936 Stuart Office Main Office Miami Office 2497 SE Dixie Highway 2201 College Avenue 444 Brickell Avenue Stuart,Florida 34997 Davie,Florida 33317 Miami,Florida 33131 0: 772.220.2365 0: 954.472.4465 0: 305.940.0381 F: 772.220.2273 F: 954.370.6410 F: 786.391.3689 DATE: May 22, 2015 CLIENT: PROPOSAL: 00007713 Barry University Barry University 11300 Ne 2nd Ave ATTN: FACILITIES MANAGER 11300 Ne 2nd Ave Miami Shores, Fl 33161 Miami Shores, FI 33161 .... ......... .... ............ ..... ......... .......... . ............................................................. ......... ........_... ..._..... ... .................................... Phone: 305-986-4751 Fax: CONTACT: Jeff Yao We propose hereby to furnish material and labor, complete in accordance with specifications below for the sum of Ten Thousand Nine Hundred Ninety And 15/100 Dollars. • Disconnect fan coil drains in (8) rooms and reroute into closet and run down through the floor slab and install (2) new main 1-1/4 PVC drain piping install above existing ceiling on the first floor of the Webber building. • Room#250 & 252 in one common drain to below • Room#251 & 253 in one common drain to below • Room#254 & 256 in one common drain to below • Room#255 & 257 in one common drain to below • Room#258 Replace chill water riser pipe insulation located in the closet with 1-1/2" foamglass pipe insulation and new rubber back to the fan coil connections. • The drain piping in the closet room closets shall be 3/4" PVC and insulated with 1/2" rubber insulation • Floor penetration and fire caulking in the closets included. • Approximately 150' of drain piping located in the ceiling of the first floor shall be insulated with 3/4" thick rubber. • Main drain piping shall run into the mechanical room and out through the east wall to a French drain. • Install French drain well in ground outside mechanical room east side included. • Daily clean up included. • Work to be done during the hours of 7:00am and 4:30pm Monday through Friday. • Labor 122 Hrs. @ $75.00=$9150.00 • Material $1290.15 • Scissor Lift Rental $550.00 THERMAL STANDARD TERMS,CONDITIONS AND EXCLUSIONS ARE PART OF THIS PROPOSAL. Customer Initial NOMINEE 12615 SW 1321E Street Unit t Miami,FL 33186 , P.3-.-F 305.6]0.0630 wwx.hm"nears. B.Wei P.E.,I EED•AP,CxA No.52146 Eduardo Aamos P.E.,LEEO®AP No.56741 Gregory M.Jensen P.E.,LEED®AP No.63828 SYNALOVSKIRDMANIKSAYE roaam." •nmm.� Fa¢I>�ladac 3 18DD A -*DERr FL506 931d T954.961AM E95549611sw YnMW.�Ima10•m@ Msrad!y-b s{i,AIA AP001160 RM 253 � SEAL LICENSE NO.AA26001863 r XISTING W CU-11 EXISTIN --- I FCU-2 ____� t— •• �• • tam 1"CD PIPING DOWN TO RM 251 1"CD 1"CO PIPING DOWN TO opy •• • Z•• • GRAND HALL CEILING RM 252 GRAND HALL CEILING •••••• Meg• 4••• • • JUN Ott •••• ,•o ....• • EXISTING---it i r---- XISTING • • �•Q • ••• • FC NE J }Li' cu-zs LLclu••• `---- -- - • • • > ••••• 4e •• • ••• • NOTE: CONDENSATE DRAIN LINE SHALL BE Z• • • z INSTALLED AS HIGH AS POSSIBLE AT 1/4" RM 249 RM 250 = 5- PER FOOT SLOPE. ALL CONDENSATE DRAIN a o LINES SHALL BE SCH. 40 COPPER DWV WITH `y O 3/4-INCH ARMAFLEX INSULATION. ,j o m RM 247 RM 248 0 EXISTING----' 5 0 w -�EXISTING FCU-2 FCU-25 V L___ � RV DO ocswPnox - - vm awx u um CD "CD 1'CD PIPING DOWN TO 1"CD PIPING DOWN TO GRAND HALL CEILING GRAND HALL CEILING a a - CD 1"CD a DESIGN I ® DELIVERABLE:PERMIT ISSUE EXISTING---- -'-- EXISTING FCU-2 I FCU_IN ISSUE DATE: 09/05/2014 `---- ---- � PROJECT NUMBER:1050-131107 DRAWN BY: s RM 245 RM 246 CHECKED BY: 2nd FLOOR F®r CLOSET 222 B FLOOR PLAN 222 E g 1 PARTIAL FLOOR PLAN 9 SCALE:3119'=1'4T 2 KEY PLAN MH ��/f, SCALE 1'=50'_W TI IENGINEERS 129,S SW,32ntl SxeM Unil I Miami,FL 33166 , P.305.610.0920 F.305.6700830 www. 1190,11 0m DEMOLITION NOTES: 1. REMOVE IXISrING OU TWOK ABOVE EKI9nNG CEILING I Bul Wei P.E.,LEED®AP,CXA No.52146 AS NEEDED FOR THE INS k,,,ILLLLIATION OF NEW DUCTWORK. Etl—d,Ramos P.E.,LEER®AP No.58741 2. EXISTING AIR HANDUIG LOCATED ABOVE THE Gregory M.Jensen P.E.,LEFD•AP No.63828 EXISTING CEILING S L B CAPPED D ABANDO ED. 3. EXISTING FRESH AIR 0 R LOCATED ABOVE THE EXISTING CEILING SH L B REMOVED.THE WALL SY1NAk.OVSTCiROMANtXSAYE ermo-e..-rtd.q,ea,a>ay. SOUIH OPENING SHALL BE TC ED. EN?fJ,N'E tat LaoBDMg=33319 EXISTING AHU-3 TO R-MAIN.PRI 1J fat+�^��A3D1b AHU CONTROLS WITH VpV BO%ES. 1! TgK%ISM OUTSIDE AIR 70 200 CFM.PRO VID NEW F954.961,MW DEMAND VENTILATION CbNTROLS. EXISTING wWtYAvslCRkl� T—� AHU-3 _�` � 'ENSATE WELL SEE DRY ^ CONNECT TO EXI$RNG RA PlE M -wEW'D AL WmM SymbM AIA T VESTIBULE 26X1- 134 I r�</ ( SEAL _ /I B { 200 FM j L 2 E12X1 ONNE T TO p i /A PROVIDE NORMALLY CLOSED MOTORIZED -- DNA+ + DAMPERS FOR EXHAUST DUCT.DAMPERS SHALL I I E .NLLOPERATIONS; M OPEN WHE EF-2 IS AC VATED'. _5 I + U - ff-2 B 1B X9 x E 400CFM r Co 250CFM / MEN E X �VpG^STI 4/ H W;IP/EN'S DW B"0 LICENSE NO.AA26001863 o SCFM AJ C .,BDG VAV 3.0;1 n'J1s - 1 18 18X18 S4 VAW4 T T DG W BDG T M I- LOF1fffNSATE-GRAIN-LIRE-AT-tiEIC1R ____ 17 18 1 INSTALL AT 1/4-PER F00T SLOPE.ALL CONDENSATE DRAIN UNES SHALL BE j V1 SDH.40 COPPER DWV WITH 3/4-INCH ARMAFLEX INSULATION. ( J tllT D;x�a • • Z. ••••• o !!! v,s' _• GATI�ERING ai-JN c? , o • S,ACE r n S .CE •. I;-----------------------------------------------------------'--- O •.•.• W1 me- *.• • ••••• C3 • jW ¢ � ••••• '� • ••••: \ WEBERGRAND ( S .ALL • ' ••• • 1-CO DRAIN LINE '129 •••• FROM ABOVE(TYP lz •••• OF • • • ----------------------- ____------------ __------______-_______' • • • • •• •• j P' I� • m ;______________________________________________ _I •••••• Q• Iii 'i1 ' /�/ • j v(6)4-FT,2SLOTs • • WlJJ • ••••• I ia`Q soo cFn+EA s2'e >•�••• �•�•z ?W F ./FORM z Oo o. z 3 \ $TNR CO3 C-8Y 128 NEWS f;G LOUVER DOOR LOUVERR DQO �,FADE I • � I IL�:J I 8 a DESIGN DELIVERABLE:PERMIT ISSUE vv v 15SUE DATE: 09/05/2014 NORTH PROJECT NUMBER:1050-171107 ERAN^E 13Ei y � DRAWN 0Y: ----- _------------- _______'�ICHECKED BY: T- e gI i Aa SxEEi imF: 1st FLOOR FLOOR PLAN 3 i s ,j 1 -1 -1 F fil MECHANICAL PLAN KEY PLAN ►1�1 LL SCALE:1/0•=1'-0' 2 1v1 1 SCALE 1'=40'-0"