Loading...
RF-15-718 a Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-236188 Permit Number: RF-3-15-718 Scheduled Inspection Date: July 21, 2015 Permit Type: Roof Inspector: Rodriguez,Jorge Inspection Type: Final Roof Owner: PRICE,JOSEPH Work Classification: Flat Job Address:550 NE 94 Street Miami Shores, FL Phone Number (202)997-1325 Parcel Number 1132060140940 Project: <NONE> Contractor: TOP SEAL SERVICES Phone: (305)754-7844 Building Department Comments RE-ROOF TWO FLAT ROOFS Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-231290. Supply photos of roll flashing at intersection with slope Need: Uplift test Failed ❑ Renailing affidavit Remove cement at bottom of flat the for drainage , 1�� Correction Needed S Re-Inspection Fee No Additional Inspections can be scheduled until re-inspection fee is paid. July 20, 2015 For Inspections please call: (305)762-4949 Page 12 of 39 _7 Lab Report No. 124600 FLORIDA TEC PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY C.A.#30448 Lab Certificate#13-0507.02 CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO-DADE COUNTY PROTOCOL TAS-106 PROPERTY ADDRESS. 550 NE 941 St., Miami Shores PERMITNo: OWNER: Price ROOFING SQUARES: 1 CONTRACTOR: Murphy Roofs ROOF PITCH: 3.5 TILE TYPE: Flat INSPECTOR INITIALS: JC ATTACHMENT: Polyfoam TESTDATE: 07/13/2015 Testing E ui ment: Digital Chatillon DFIS 200 Test Tabulation Required Testing Force: 35 Ibs No. RES ULT No. RESULT No. RES ULT No. RESULT No. RESULT 1-6 Passed THIS ROOF HAS:PASSED ® FAILED E]THE STATIC UPLIFT IN ACCORDANCE WITH MIAMI-DADE COUNTY TAS 106. i Sloped Roof 3 1 2 _ 4 5 �6 Flat Roof Si I , r—, Alberto Cardona,P.E. Lic.No. 17138 10735 SW 216'h St. Unit 416 Tel:305-256-4550 www.FforidaTEC.net Miami FL 33170 Page 1 1 Fax: 305-256-6833 AFFIDAVIT OF COMPLIANCE WITH ROOF DECKING ATTACHMENT AND SECONDARY WATER BARRIER HURRICANE MITIGATION RETROFIT FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTLAL STRUCTURES PURSUANT TO SECTION 553.844 F.S. To: Miami-Dade County Building Department 11805 Coral Way, Suite 111 Miami, FL 33175 Re: Owner's Name . Property Address 530 Roofing Permit Number Dear Building Official: I A�� 4`�certify that the roof decking attachment and fasteners have been strengthened and corrected an a-Wecondary water barrier has been provided as required by the "Manual of Hurricane Mitigation Retrofits for Existing Site-Built Single Family Structures" adopted by the Florida Building Commission by Rule 9B-3.047 F.A.C. Qualifying Agent SZgna�ture of Qualifying Agen �--- IJ l Print Name 1 v� STATE OF FLORIDA COUNTY OF MIAMI-DADE � 30S.- 00 Sworn to and subscribed before me this day of L 120 l _ f Myr (SEAL) $ Personally known or Produced Identification ! r!mrnls.n,l�cn!nKi Ktcl lly l) iinr nl.:i l.., 1,.th,_'Ni.r!;nK A I Ida ll42lril'1IWJI J.. gOR.ES Miami Shores Village 10050 N.E.2nd Avenue NE .,.. ' Wt*61 ftafi Flat Miami Shores, FL 33138-0000 "Flod` Phone: (305)795-2204 v ,, Expiration I0/3112015 � N Project Address Parcel Number Applicant 550 NE 94 Street 1132060140940 Miami Shores, FL Block: Lot: JOSEPH PRICE Owner Information Address Phone Cell JOSEPH PRICE 550 NE 94 Street (202)997-1325 p_ MIAMI SHORES FL 33138- 550 NE 94 Street MIAMI SHORES FL 33138- Contractor(s) Phone Cell Phone Valuation: $ 3,250.00 TOP SEAL SERVICES (305)754-7844 Total Sq Feet: 510 Type of Work:Re Roof Available Inspections: Additional Info:RE-ROOF TWO FLAT ROOFS Inspection Type: Classification:Residential Tin Cap Scanning:3 Final Roof Roof in Progress Renailing Affidavit Review Roof Review Roof Fees Due Amount Pay Date Pay Type Amt Paid Amt Due Bond Type-Owners Bond $500.00 CCF $2.ao Invoice# RF-3-15-54988 DBPR Fee $3.75 05/04/2015 Check#: 1196 $722.90 $50.00 DCA Fee $3.75 03/30/2015 Check#:4931 $50.00 $0.00 Education Surcharge $0.80 Bond#:2700 Permit Fee-New Roof $250.00 Scanning Fee $9.00 Technology Fee $3.20 Total: $772.90 In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans,drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL,PLUMBING,MECHANICAL,WINDOWS,DOORS,ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructs 7oning. Vutbprm , I authorize the above-named contractor to do the work stated. May 04, 2015 o e Signature:Owner / Applicant / Contractor / Agent Date Building Department Copy May 04, 2015 1 Miami Shores Village Building Department artment 10050 N.E.2nd Avenue,Miami Shores,Florida 33138 MAR 3 0 2015 Tel: (305)795.2204 Fax: (305)756.8972 INSPECTION'S PHONE NUMBER: (305)762.4949 FBC 20 BUILDING Permit No.04�-- PERMIT APPLICATION Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS: S'S 0 0 9. N-'� S� ; City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: X I- 37-0 6 - p 1 05 4 0 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name(Fee Simple Titleholder): -t AMc y" 00C &96 Phone#: cWa-9q7- O' PS Address: � o N i= I t-m*- -a-: City: 1&k.c4 w` S1tir,re-s State: Zip: Ws(3 Tenant/Lessee Name: Nitr Phone#: a?'t'` Email: CtAd tTSsz�_ (S" 00MC&Xi- NAA CONTRACTOR: Company Name: \ *s'; YT__ Phone#: Address: City: State: Zip: Qualifier Name:--v--��—I " -. Phone#: � 7 � State Certification or Registration#: Certificate of Competency#•_ L. / Contact Phone#: j/V) k, E ail Address: DESIGNER:Architect/Engineer: Phone#: J�V Value of Work for this Permit:$ Z� "` J (` Square/Linear Footage of Work: Type of Work: ❑Addition ❑Alteration ❑New ❑Repair/Re p lace ❑D.emolition Description of Work: _'..4 . 01 e Color thru tile: Submittal Fee$ Permit Fee$ CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Bond$ V Notary$ Training/Education Fee$ Technology Fee$ Double Fee$ Structural Review$ TOTAL FEE NOW DUE$ �ZZ Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS and AIR CONDITIONERS,ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN• I YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:" Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice ofncement ust be osted at the job site for the first inspection which occurs seven (7) days after the building permit is issue In th bs nce of suc posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur Signature Owner or Agent CIMontr for The foregoing instrument was acknowledged before me this The foregoi instr ent w ackn edged before me this day of ,20 ,by �Xld � day of 2� 20 (S,by who is personally known to me or who has produced R06GIa who is Ktsonall known tom r who has produced Dr1VPYS L.ICWV t As identification and who did take an oath. as identification and who did take an oath. `j%1111111111 NOTA Y LI ```�1PNA•BT•VA /���' NOTARY PUBLIC: %% \•••'• 0 1 q••••�O '0 . N 9 ,. s • Sign: • :s Sign: Print: = S i' �mm. • ':print: —` My Commissi n Expires: N S NO.FF I24M QN4y Commiss' n Expi;A% 7 fies: r. G to//1111111� , APPROVED BY Y Plans Examiner Zoning Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) -- - HIGH-VELOCITY HURRICANE Z Florida Building Code Edition 2010 ' r ' High Velocity Hurticane Zone Uniform Permk Appketion Form. MIR 3 4 2015 Section A (General Information) �- • �� --� � C Master Permit No. Process No. • Contractor's Name Job Address ✓ S qT ROOF CATEGORY D Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adheslve Set Tile ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles ❑ Prescriptive BUR-RAS 150 C ROOF TYPE ❑ New Roof ❑ Reroofing ❑ Recovering ❑ Repair ❑ Maintenance SYSTEM INFORMATION Low Slope Roof Area(SF) Steep Sloped Ro Area(SF) Total(SF) Section 4ftof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly : identify dimensions of elevated pressure zones and location of parapets. • - _ .7 • _ 1 , i • 7 • • • Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Hoof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (It a component is no��d, identify as"NA") System Manufacturer; i4"„3r'4f,9 �� -�> Field: ! ”oc @ Lap,#Rows @ /° `"oc v ! NOA No.: Perimeter: r "oc @ Lap,#Rows @ "oc Design Wind Pressures,From RAS 128 or Calculations: Gy Corner: "40-W 7oc @Lap,#Rows @ "oc Pmaxl: _Pm .7Pmax3: !' !S Number of Fasteners Per Insulation Max.Design Pressure,From the Specific NOA Board System: r Deck: Field: Perim�(e i/ i Corner ' �' Type: / i, Illustrate Components Noted and Gauge/Thickness:_ petails as Applicable: Slope: s ': /? Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Anchor/Base Sheet&No.ofPly(s): !J• � Strip, Base Flashing, Counter- Flashing, Coping,Etc. Anchor/Base Sheet Fastener/Bonding Material: Indicate: Mean Roof Height, Parapet Height, 1, Height of Base Flashing, Component Material, i — Material Thickness, Fastener Type, Fastener Insulation Base Layer; /:J � ri.%AII Spacing or Submit Manufacturers Details that " —�,� Comply with RAS 111 and Chapter 16. Base Insulation Size and Thickness: l=° � Base Insulation Fastener/Bonding Material: Top Insulation Layer: - ��"~"'�' Top Insulation Size and Thickness: Parapet ' d;Y` Height /c�tiilr y SE, Top Insulation Fastener/Bonding Material: t BasVoheet(s)&t o.of Ply(sl; j` "'—'^F` %�%/° FT t% /! Base Sheet Fastene Bond't1g Material: Mean x rli'y Roof Height Ply Sheet(s)&No,of Ply(s): i Ply Sheet Fasten r/Bonding M ferlai: Top Ply: `/7i/° ~';fir! f�•� Top Ply Fastener/Bo_p ding Maters 0 Surfacing: MAW MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/eeonomv Polyglass USA,Inc. 150 Lyon Drive Fernley,NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self-Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official This NOA revises NOA# 13-0514.10 and consists of pages 1 through 33. The submitted documentation was reviewed by Alex Tigera. MIAMI-DADE COUNTY NOA No.: 13-1217.01 .��W P Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 1 of 33 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Elastobase 65' 2"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type I base sheet. XtraFlex SBS Glass 65' 8"x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Base Type I base sheet. Polyglass G2 Base 108' x 36" ASTM D 4601 Asphalt-coated fiberglass reinforced base sheet Type II Polyanchor 250' x 48" ASTM D 4601 A polymer woven,high performance, synthetic base Type II sheet. Elastobase P 65' 8"x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered, fire-rated, fiberglass reinforced, SBS (1.5-mm) Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 3-3/8" ASTM D 6163, Self-adhered,fire-rated, fiberglass reinforced, SBS PLUS FR Type I modified bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V(1.5- 66' 8"x 3' 33/8" ASTM D 6163, Self-adhered,fiberglass reinforced, SBS modified mm) Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA V 66' 8"x 3' 3_3/8" ASTM D 6163, Self-adhered, fiberglass reinforced, SBS modified PLUS Type I bitumen membrane with a self-adhering back face and a smooth top surface. XtraFlex SBS Base 66' 8"x 3' 33/8" ASTM D 6163, Self-adhered,fiberglass reinforced, SBS modified SA Type I bitumen membrane with a self-adhering back face and a smooth top surface. Elastoflex SA P FR 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex SBS G SA 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fire-rated,polyester reinforced, SBS Type I modified bitumen membrane with a self-adhering back face and a granule top surface. C •DADE COUNTY NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 2 of 33 Elastoflex SA P 32' 10"x 3' 3-3/8" ASTM D 6164, Self-adhered,fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. XtraFlex APP S 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polybond 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Polyflex G 32' 10"x 3' 3-3/8" ASTM D 6222 Torch applied,polyester reinforced,APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Polyflex SA P 32' 109'x 3' 33/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyflex SA P FR 32' 10"x 3' 3 3/8" ASTM D 6222, Self-adhered,fire-rated,polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. XtraFlex APP G SA 32' 10"x 3' 3 3/8" ASTM D 6222, Self-adhered, fire-rated, polyester reinforced,APP Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G SBS SA 32' 10"x 3' 33/8" ASTM D 6164, Self-adhered, fire-rated, fiberglass reinforced, SBS FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a granule top surface. Polyfresko G APP SA 32' 10"x 3' 33/8" ASTM D 6222, Self-adhered,fire-rated, polyester reinforced,APP FR Type I modified bitumen membrane with a self-adhering back face and a granule top surface PolyKool 32' 10"x 3' 33/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. XtraFlex Kool APP S 32' 10"x 3' 33/8" ASTM D6222 Self-adhered,polyester reinforced,APP modified SA Type I bitumen membrane with a self-adhering back face and a white film laminate on the top surface. Polyglass APP Base 65' 8"x 3' 33/8" ASTM D 6509 APP modified asphalt coated fiberglass reinforced Type I base sheet. MIAMI•DADE COUNTY NOA No.: 13-1217.01 �� `"'s Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 3 of 33 PG325 Cold Process 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type III BUR roofing. PG 100 Asphalt Primer 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of. tube or 17 oz. spray selected asphalts used to promote adhesion. can XtraFlex 10 Asphalt 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of Primer tube or 17 oz. spray selected asphalts used to promote adhesion. can PG350 Mod Bit 1,3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Adhesive tube Type III modified bitumen membranes. PG400 Plastic Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG425 Wet/Dry Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG450 Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement. Cement tube PG500 MB Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement for use Cement tube with modified bitumen membranes. Polyplus 35 Premium 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. XtraFlex 35 Premium 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. Polyplus 45 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement. Flashing Cement tube Polyplus 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement for use MB Flashing Cement tube with modified bitumen membranes. XtraFlex 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered,rubberized flashing cement for use Modified Wet/Dry tube with modified bitumen membranes. Cement Polyplus 55 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A mastic compound for use as a roof flashing Modified Flashing tube adhesive. Cement CDADECOUNTY NOA No.: 13-1217,01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 4 of 33 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Polytherm-H Polyisocyanurate foam insulation Polyglass USA,Inc. Polytherm Polyisocyanurate foam insulation Polyglass USA, Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp High Density Wood Fiberboard Wood fiber insulation board Generic DensDeck,DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels,LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels,LLC ENRGY-3, JM ISO 3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating,LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation MIAMI•DADE COUNTY NOA No.: 13-1217.01 LIM(IMIN Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 5 of 33 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast Fasteners 12, 14 & Insulation fastener for wood, SFS Intec,Inc. 15 HS steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2 '/8"x SFS Intec, Inc. Hex Plate 31/411 3. #14 Roofgrip Insulation and membrane Various OMG,Inc. fastener 4. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG,Inc. 5. Trufast 414 HD Fastener Insulation fastener for steel and Altenloh,Brinck&Co. wood decks U.S., Inc. 6. Trufast 3"Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh,Brinck& Co. Plate plate 3" round U.S., Inc. 7. Polygrip Fasteners 412,#14 Insulation fastener for wood, Various Polyglass USA, Inc &#15 steel and concrete decks 8. Polygrip Hex Plates Galvalume hex stress plate. 2'/8" x Polyglass USA,Inc 3 1/4" MIAMI•DADE COUNTY NOA No.: 13-1217.01 EUVOW1401 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 6 of 33 APPROVED SURFACING: TABLE 4 Product Product Application Specification Manufactur Name Description Rate er PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used 1'/z-2 gal/sq TAS 140 Polyglass to add life and rejuvenate existing USA, Inc. BUR roofing substrates. XtraFlex 20 Bituminous Roof A non fibered asphaltic coating used 1'/2-2 gal/sq TAS 140 Polyglass Coating to add life and rejuvenate existing USA,Inc. BUR roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof 1'/z-2 gal/sq ASTM D4479 Polyglass coating. May be applied by brush or USA, Inc. spray equipment to rejuvenate aged BUR XtraFlex Bituminous Roof An asphalt cutback fibered roof 1'/2-2 gal/sq ASTM D4479 Polyglass Coating Fibered coating. May be applied by brush or USA,Inc. spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Non-fibered aluminum roof coating. ''/2-1 gal/sq ASTM D2824 Polyglass Roof Coating Type I USA, Inc. PG650 Fibered Aluminum Roof Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass Coating Type III USA,Inc. PG700 Elastomeric Roof Coating A premium white elastomeric acrylic 1-1'/2 gal/sq ASTM D6083 Polyglass based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. PG800 Non-Fibered Asphalt An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass Emulsion Roof Coating emulsion two coats USA,Inc. XtraFlex 80 Emulsion Roof An asphalt base,un-fibered clay 3 gal/sq in ASTM D1227 Polyglass Coating emulsion two coats USA,Inc. PG850 Fibered Asphalt Emulsion An asphalt base, fibered clay 3 gal/sq in ASTM D1227 Polyglass Roof Coating emulsion two coats USA,Inc. Polyplus 65 Premium Fibered Fibered aluminum roof coating. 1%2-2 gal/sq ASTM D2824 Polyglass Aluminum Roof Coating Type III USA,Inc. XtraFlex 65 Aluminum Roof Fibered aluminum roof coating. 1'/z-2 gal/sq ASTM D2824 Polyglass Coating Fibered Type III USA,Inc. Polyplus 60 Premium Non- Non-fibered aluminum roof coating. '/2-1 gal/sq ASTM D2824 Polyglass Fibered Aluminum Roof Coating Type I USA; Inc. XtraFlex 60 Aluminum Roof Non-fibered aluminum roof coating. ''/2-1 gal/sq ASTM D2824 Polyglass Coating Type I USA, Inc. IMAMI•DADE OUNTY CNOA No.: 13-1217.01 1 "'• • Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 7 of 33 APPROVED SURFACING: TABLE 4 Product Product Application Manufactur Name Description Rate Specification er Polybrite 70 Premium Grade A premium white elastomeric acrylic 1-1%gal/sq ASTM D6083 Polyglass Elastomeric Roof Coating based roof coating(water-based). A USA,Inc. polyester fabric may be used for reinforcement with this coating. XtraFlex 70 Premium Acrylic FR A premium white elastomeric acrylic 1-1'/2 gal/sq ASTM D6083 Polyglass Roof Coating based roof coating(water-based). A USA, Inc. polyester fabric may be used for reinforcement with this coating. Polybrite 90 High Solids Silicone A premium grade high solids, single 1.25 gal/sq ASTM D6694 Polyglass Roof Coating component,moisture cure, fluid USA, Inc. applied silicone coating XtraFlex SRC 9600 High Solids A premium grade high solids, single 1.25 gal/sq ASTM D6694 Polyglass Silicone Roof Coating component, moisture cure, fluid USA,Inc. applied silicone coating Polybrite 95 Silicone Roof A single component, solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA Inc. XtraFlex SRC 8000 Silicone Roof A single component, solvent, 1.25 gal/sq ASTM D6694 Polyglass Coating moisture cure silicone coating. USA Inc. Gravel To be installed in a flood coat of 400 lbs/sq N/A Generic approved asphalt at 601bs/sq Slag To be installed in a flood coat of 3001bs/sq N/A Generic approved asphalt at 60 lbs/sq MIAMI-DAD E C UNTYM NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 8 of 33 EVIDENCE SUBMITTED: Test Agency Test Name/Renort Report No. Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3001334 02.15.00 4470 3000857 01.12.06 4470 3004091 01.12.00 4470 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 Trinity ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 02762.03.05 03.30.05 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06-RI 02.27.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164/ASTM D6222 P10490.08.08 08.13.08 ASTM D6164/ASTM D6222 P10490.10.08-RI 10.03.08 ASTM D6222 P7400.03.08-R2 10.09.08 TAS 114(D)—ASTM D1876 P10070.10.08 10.09.08 ASTM D6222 P10490.10.08-2 10.30.08 FM 4470 &TAS 114 P33970.03.11 03.15.11 ASTM D6163 /ASTM D 4601 P33960.03.11 03.15.11 TAS 114 &TAS 117 (B) 11757.12.00-1-R1 04.29.13 TAS 114 &TAS 117 (B) 11757.04.01-1-R1 04.30.13 ASTM D6164 P37590.07.13-1 07.02.13 ASTM D6164 P37590.03.13-3A 03.06.13 ASTM D6163 P37590.03.13-2-R1 02.05.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 /TAS 117 P45940.09.13 09.04.13 TAS 114 &FM 4474 P41630.08.13 08.06.13 TAS 114(H) P13760.09.09 09.10.09 ASTM D4601 /TAS 117 P45970.05.14 05.12.14 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 MIAMI•DADE COUNTY NOA No.: 13-1217.01 • r Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 9 of 33 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following: Base Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft2 Any approved Polyisocyanu rate listed in Table 2 Minimum 1" thick N/A N/A Top Insulation Laver(Optional) Insulation Fasteners Fastener Table 3 Density/ft2 Fesco Board Minimum 3/" thick N/A N/A Approved High Density Wood Fiberboard Minimum '/Z"thick N/A N/A DensDeck,DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum '/"thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One or more plies of Elastobase, XtraFlex SBS Glass Base, Elastobase P or Polyanchor fastened to the deck as described below: Fastening: Attach base sheet using OMG#14 Roofgrip fasteners and Flat Bottom Metal Plates,Dekfast 14 with Dekfast Galvalume Steel Hex Plates,Polygrip Fasteners#14 with Polygrip Hex Plates or Trufast#14 HD Fasteners with Trufast 3"Metal Insulation Plates spaced 12"o.c. in a 4"lap and 12"o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V(1.5-mm),Elastoflex SA V PLUS,XtraFlex SBS Base SA, Elastoflex SA V FR(1.5-mm) or Elastoflex SA V PLUS FR, self-adhered. MIAMI•DADE C UNTYM NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 22 of 33 Membrane: One ply of Polyfresko G SBS SA, Polyfresko G SBS SA FR,Polyfresko G APP SA, Polyfresko G APP SA FR,Elastoflex SA P,Elastoflex SA P FR,XtraFlex SBS G SA,Polyflex SA P,PolyKool,XtraFlex Kool APP S SA, Polyflex SA P FR or XtraFlex APP G SA, self- adhered. Or One ply of Polyflex G,torch-applied. Surfacing: (Optional)Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf, (See General limitation#7.) MIAMI•DADE COUNTY NOA No.: 13-1217.01 • � Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 23 of 33 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4'maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers,metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners).Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE C =31 NOA No.: 13-1217.01 Expiration Date: 10/11/17 Approval Date: 11/06/14 Page 33 of 33 POLYGLASS USA INC 150 LYON DR R14571 FERNLEY,NV 84408 USA SINGLE PLY MEMBRANE SYSTEMS Class A-Fully Adhered Deck:C-15/32 Incline:2 t tion{Optional):--Polyisocyanurate,perlite,wood fiber or polyisocyanurate/perlite board,any thickness. Barrier Board:-- in.(min)G-P Gypsum DensDeck®,mechanically fastened with all joints staggered 6 in.from the p d joints, Base Sheet:--"ELASTOBASE' sand),mechanically fastened or"ELASTOFLEX SA V PLUS FR","ELASTOFLEX SA V FR"or' LA LEX$A V FR BASE VENT"(selfadhered). PIy Sheet(OptionaI):--"ELASTOFLEX SA V R","ELASTOFLEX SA V FR"or "ELASTOFLEX SA V FR SASE VENT",(self adhered). Membrane:--"POLYFLEX$A P FR", "POLYFRESKO APP SA " "ELASTOFLEX SA P FR", "POLYFRESKO SBS SA P FR", "ELASTOFLEX SA V FR HT",(self adher r"POLYFLEX G FR", "POLYFRESKO TORCH FR","DUFLEX G FR", "ELASTOFLEX S6 G FR", SKO MOP FR", "ELASTOFLEX VG FR" or"ELASTOSHIELD TS G FR",heat fused 22.Deck:C-15/32 Incline: 1/2 Insulation (Optional): —Polyisocyanurate 1.5 in.(min.)with all joints staggered 6-in,(min.)from the Plywood joints, Base Sheet:--T me,hanically fastened followed by"ELASTOBASE" mechanically fast ned Ply Sheet(Optional), "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR"or ELASTOFLEX SA V FR BASE VENT",(self adhered) Membrane:--"POLYFLEX SA P FR", "POLYFRESKO APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO SBS SA P FR",or"DUPLEX G FR","POLYFLEX G FR","ELASTOFLEX S6 G FR', "POLYFRESKO MOP FR", "ELASTOFLEX VG FR"or"ELASTOSHIELD TS G FR",heat fused, 0 2012 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured.under UL's Follow-Up Service.Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service,Always look for the Mark on the product, UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: I.The Guide Information,Designs and/or Listings(files)must be presented in their entirety and in a non-misleadin;manner,without any manipulation of the data(or drawings),2. The statement "Reprinted from the Online Certifications Directory with permission from UL"must appear adjacent to the extracted material.In addition,the reprinted material must include a copyright notice in the following format:"0 2012 UL LLC". `5 K� l�e �<OIto SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope.As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner ant the contractor.The owner's initial in the designated space indicates that the item has been explained. Aesthetics-Workmanship:the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics(appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code, should be addressed as part of the p6reement between the owner and the contractor. 2. Renailing wood decks:When replacing roofing,the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. —4 ,, Common roofs:Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses,condominiums,etc.) In buildings with common roofs,the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance;therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water:The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers(wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers(wall outlets)are not provided. It may be necessary to install overflow scuppers in accoodance with the requirements of Sections R4402, R4403 and R4413. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly(the building itself).The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional ventin which can result in extending the se ice life of the roof. w gea wn nt`s Signature Date ContractoT�natu—re Date Y: Revised on 7/9/2009 LD i' r'