Loading...
RC-14-1741 (3) Miami Shores Village Building Department JAN 16 M5 ` 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305)795-2204 Fax:(305)756-8972 INSPECTION LINE PHONE NUMBER:(305)762-4949 FBC 20 BUILDING Master Permit No. /<-- 9--// -/ 7 `f/ PERMIT APPLICATION Sub Permit No.(ZF IS J 10 f ❑BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 13: ,clLd I06 S t City: Miami Shores County: Miami Dade Zip: _?3` 576 Folio/Parcel#: �l 'VIJv '–�/ Is the Building Historically Designated:Yes NO i -�` Occupancy Type: S,L c. Load: Construction Type: /p -Flood Zone: � BFE: FFE: OWNER: Name(Fee Simple Titleholder): ET6 We4e,hk, GZC Phone#: Address: /, U ,) City: / ' `F✓� i S" ✓zs State: r L Zip: •3 Tenant/Lessee Name: Phone#: Email: / /l CONTRACTOR:Company Name: v/` klVK 6rQPhone#: ( �h/�� —LY 7J Address: 14-70q pp/-- City: -'t✓t `( State: F �d Zip: Qualifier Name: CJ Phone#: State Certification or Regis ration#: 6 6C132 2,5 Certificate of Competency#: DESIGNER:Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: � Square/ 'near Footage of Work:, ' LSU Type of Work: ❑ Addition ❑ AlterationNew ❑ Repair/Replace ❑ Demolition Description of Work: Spe .1 color f colb'r thru tile: �� cc,,,&I �i%f .v Submittal Fee$4 Permit Fee$ 3W VV CCF$ CO/CC$ Scanning Fee$ Radon Fee$ DBPR$ Notary$ Technology Fee$ Training/Education Fee$ Double Fe--e$$ Structural Reviews$ Bond$ �7�.Jy •�� ) 1 /\ TOTAL FEE NOW DUE$�"10 L`0 (Revised02/24/2014) Q 10 e) Bonding Company's Name(if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name(if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding$2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature XSignature OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before me this I(ate day of 11f 120 15 by ti' day of 20 / , by y(�i z- C LSF who is personally known to who is personally known to me or who has produced as me or who has produced as identification and who did take an oat identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: OS U ERO EE176700 Sign: Sign: Print: 133 �`. Notxy POW•two Seal: Seal: M,00mm.Egim rFOi`Fl;`,••' Commlf$ionI 09 llllllll APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) SNORES Miami shores Village goes Building Department ° 10050 N.E.2nd Avenue R Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE- BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 6 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: eX i,,a I f-Ae-. LLC tv L ¢ tt Property Address: /3:7 ,C S F Roofing Permit Number: Dear Building Official: �Jzy4- e certify that I am not required to retrofit the roof to wall connections of my building because: ❑ The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. The building was constructed in compliance with the provisions of the Florida Building Code (FBC)or with the provisions 0 1994 edition of the South Florida Building Code (1994 SFBC) f—fi ✓�-- �r i e� r Signatu Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is own r th bove property mentioned. Sworn to and subscribed before me this-AAL-day of ,ft RRERO Notary Public, Sate of Florida at Large 13310N#EE176700 06,2016 AOT 153 eNofeey8ervkeoom • When the just valuation of the structure for purpose of ad valorem to tion is eq to or etha Z111 , ,an t e wilding was not constructed with FBC nor a 1994 SFBC.Then you must provide a building application from a General ntract a Roo all connection Hurricane Mitigation. ,SNORES n Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner — Workers' Compensation Insurance Exemption Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees,including the owner,must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC,a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State,Division of Corporations;and 3. The corporation is registered and listed as active with the Florida Department of State,Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption. In these circumstances,Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company. Therefore,you may be personally liable for the worker compensation iniuries of any person allowed to work under this permit Please check with your insurance carver since most property insurance policies DO NOT cover this type of liability. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Owner Contractor Print Name: ,.VTC� Print Name:– � Signature: Signature: State of Florida) State of Florida) County of Miami-Dade) County of Miami-Dade) Sworn to and subscribed before day of , Sworn to ayd subscribed before me this ft- GUE ER day of 20 :N M EE1 �1 JI By t BY fin (SEAL (SEAL) DUVET L NMNM T n uce Type of Ide II -!ft un CWAMINloe#FF TM A • • • • Hit N • FA I ■■■■■■■■■■■■■■■■■■■■MEMO■■■■■■■■■■■■■■■■■■■■■■■■■■■■■�.��.. ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Gw.l'A■r7■In �i�Mii ■■■■■■■■■■■■■■■■■■■■■■!■■■■■■■■■■■■■■■■■■■■IIL'�fr■■Fa■tCiilli!■11 ■■■■■■■■■■■■■■■■■■■`■fq■■■■■■■■■■■■■■■■■■■■■■IE■t7■CJ■E■■In!■11 ■■■■■■■■■■■■■■■■rel■ ..ar■■7■■■■■■■■■■■■■■■■■■■IF.;■Ei■[�rJ■ri■IF■1! ■■■■■■■■■■■■■■■■■►�nrl■iLirli.`■■■■■■■■■■■■■■■■■I■i■iJ■ a ■r.10 l ■■■■■■■■■■■■■■■■■■ ■n%■rmw■■■■■■■■■■■■■■■■■!a■■-4■.50-im r,�■r:ul i ■■■■■■■■■■■■■■■■■■■■I�■■■\■■■■■■■■■■■■r.i 1�■■■■[+■■�■I�:1■�i�■■■■■! ■■■■■■■■■■■■■■■■■■■■11■■■■■■■■■■■■■■■■►/■■■■■■■J■:i■I�■■�.:..�... ■■■■■■■■■■■■■■■■■■■■I■■■■■■■■■■■■■■■■►I■■■■■■■■11■W■I 1■■:i■■■■■ ■■■■■■■■■■■■■■■a■i■■'Jt■■■■■■■■■■■■■■II■■■■■■■■�7■L'_■11■■i■■■■■■ ■■■■■■■■■■■■■■■■�`l/.■■■■■■■■■■■■■■■■r■■■■o11MEMEMONESOMMOME ■■■•i■G■III■i ■■1:J■ ■■■■■■■■■■■■■■■■■'ei■■■■■■■■■■■■■■■■!ISO■■RiaR■ia■W■IlSq!!j■■h1■ MMOMEMENESEMONOMMMMEMENSEEMEENNeISMINNEMMMMMM ■■■■■■■■■■■■■■■■I■■■■■■■■■■■■■■■■■■111■■■■■■■■I■■■F■1l■�11■■�■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■Gc�w■■��r■A■■■It■■f!■1 Imo:::!■11■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■lai.:.-. ■11"OMEN IIL�■C�l■I■!r11■■1 ■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ii■■■Ihl.!■■■IIL'■■�■!!�■�I■■lid■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■!■■■■■■moss■■'p5:a■11=!■ ■■■■■■■■■■■■■■t■■■■■■■■■■■■■■■■■■■■■■a■■■■■■■i■■ir■`2■I■■Illi■ ■■■■■■■■■■■■■■■■■■■■■■■■■■/•7/IG■■■■■■■■■■■■■■■■1■■■■■■Ill■■11■■ iiiiiiiiiiiiiiiiiiiiiiiimm----mmmmiiiiiiiiiiiiiiiii:iiii Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: f Product Approval Number: Z-` G z zz , 02 Minimum Design Wind Pressures,If Applicable(From R 127 or Calculations): P1: q�.O P2: yl_�P3: t-11.0:AS Maximum Design Pressure Product Approval Specific System: Method of Tile Attachment: ` �}E Steep Sloped System Description Deck Type: r Y 4s�Le =Slope: TYPe Underlayment: �C! Insulation: [-. 1110- Fire Barrier:Elt/ Ridge Ventilation? Fastener Type&Spacing: r/ r �v ff- Ei2 Adhesive Type: �- Type Cap Sheet: 7v -0� E=7 Roof Covering: Mean Roof Height:_� � Efll-) J'�j����� ,- 4A Type&Size Drips Edge: O ,, J J Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based the systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf. If the Mr values are greater than or equal to the M, values,for each area of the roof, then the the attachment method is acceptable. Method "Moment Based Tile Calculations Per RAS 127" (P', x�' -LL 7�-M9:�'.=Mr1 L-t/L Product Approval M ( z• x A = 2s63`� -Mg: 6,05-=M, 17,53 Product A f (P,:11V0 p xApproval M, _-�� -M9: .GS=Mr3 2� Product Approval M,_,!i s Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance(Mr)From Table Below Product Approval Mf Mean Roof Height M Re uired Moment Resistance* --► Roof Slope 15' 20, 25, 2:12 30' 40' 34.4 36.5 38,2 3:12 .39.7 42.2 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 1 25.9 27.1 28.2 30.0 *Must be used In conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3.Compare the values for F'with the values for F,. If the F'values are greater than or equal to the F,values,for each area of the roof, then the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P,: x 1: = x w:=_ )-W; x cos 0: - =F,, Product Approval F' (Pz: x 1: = x w:=_)-W; x cos 0: - =Frz Product Approval F (P3: x 1• = x w:=_)-W x cos 0• - =F,3Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance K Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions I=length product Approval w=width All calculations must be submitted to the Building Official at the time of permit application. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to this section,it is the responsibility of the roofing contractor to provide the owner with the required roofing permit,and to explain to the owner the content of this section.The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally,the following items should be addressed as part of the agreement between the owner and the contractor.The owner's initial in the adjacent box indicates that the item has been explained. _1.Aesthetics-Workmanship:The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards.Aesthetics (appearance)are not a consideration with respect to workmanship provisions.Aesthetic issues such as color or architectural appearance,that are not part of a zoning code,should be addressed as part of the agreement between the owner and the contractor. i_2.Renailing Wood Decks:When replacing roofing,the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403.(The roof deck is usually concealed prior to removing the existing roof system.) 6 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4.Exposed Ceilings:Exposed,open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance,therefore,roofing nail penetrations of the underside of the decking may not be acceptable.This provides the option of maintaining this appearance. — -5. Ponding Water:The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. Q'�, 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402,R4403 and R4413. -6__7.Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Exception:Attic spaces,designed by a Florida licensed engineer or registered architect to eliminate the attic venting,venting shall not be required. Owner' 's Si ure Date Contra4r's gnature LL-)6 �r Property Address Permit Number MIAMI-DADE COUNTY MAW PRODUCT CONTROL SECTION "P,ilan 11805 S W 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.Hov/economy 3M Company 3M Center Building 0220-05-E-06 St.Paul,MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTrk1 2-Component Foam Roof Tile Adhesive AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. QMLbDADEcouNTY NOA No.: 14-0805.01 Expiration Date. 05/10/17 Approval Date: 09/04/14 Page 1 of I1 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3Mrm 2-Component Foam Roof Tile Adhesive AH-160 as manufactured by 3M Company as described in this Notice of Acceptance.For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat,low,and high profile roof tile systems using 2-Component Foam Roof Tile Adhesive AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2-Component N/A TAS 101 Two component polyurethane foam adhesive Foam Roof Tile Adhesive AH-160 Foam Dispenser N/A Dispensing Equipment RTF1000 ProPack®30& 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami-Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 2-Component Foam Roof Tile Adhesive AH-160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball,TX. PHYSICAL PROPERTIES: Property Test Results Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ftz Moisture Vapor Transmission ASTM E 96 3.1 Perm/Inch Dimensional Stability ASTM D 2126 +0.07%Volume Change @-40'F., 2 weeks +6.0% Volume Change @158°F., 100%Humidity,2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 14-0805.01 MIAMI•DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1PA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[i] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance.Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3MT"2-Component Foam Roof Tile Adhesive AH-160 shall solely be used with flat, low, &high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120, 4. Roof Tile manufactures acquiring acceptance for the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-0805.01 MIAMbDADE couNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 3 of 11 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH- 160. 2. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall be applied with Foam Dispenser RTF 1000 or ProPack® 30& 100 dispensing equipment only. 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details'herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 14-0805.01 MIAMI-DADE COUNTY � � - Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course-Flat,Low,High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-Piece Barrel (Cap Tile) Two Piece 2 Beads(1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami- Dade County Product Control Seal as shown below. MIAMFDADE COUNTY �...• 1 BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-0805.01 MIAW, ECOUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 5 of 11 ADHESIVE PLACEMENT DETAIL# 1 OUR 9hmsr3cexanauc vs�ddw�san•�hn Flat/Low Profile Tile h „ � 1. Starting at the eave course, apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam # paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. .. Kit 000P1 �� tVaiitfrrsvoncrmafia Medium Profile/ Double Pan Tile JWk&M ragvlrsd) � 1 __ P+d�ytl +�tlri 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. t 2 6,L Nd* 2. Continue in same manner. Insure approximately 17 (109.7 cm2)—23 (148.4 cm2)square inch adhesive contact with the underside of the tile. �re &we Course- High Profile/Single Pan Tile Mrhrnr.gvardt t' `'w,., ,.-FaulrPjrfBwwwdeeM7itMi 1. Starting at the eave course, apply a minimum 2" (50.8 mm)x 10"(254 mm)x 1"(25.4 mm)foam paddy onto the underlayment positioned as shown ear,o� under the pan portion of the tile closest to the overlock of the tile being set. Haws 2. Continue in same manner. Insure approximately 17 canal ? ✓ "` sw2 2 (109.7 cm )—23 (148.4 cm )square inch adhesive contact with the underside of the tile. 7it Drip modge NOA No.: 14-0805.01 MLAMI•DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 6 of I1 ADHESIVE PLACEMENT DETAIL#2 + ► �t�alc �� w�w.,,.�n.rAr Flat/Low Profile Tile mgwrvd? 1. Starting at the eave course, apply a minimum 2»(50.8 mm)x 10"(254 mm) x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17(109.7 CM2) —23 (148.4 cm )square inch adhesive contact with the underside of the tile. r 2. At the second course, apply a minimum 2" (50.8mm) F,, x 7"(177.8 mm)x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile t sly- -_ being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2)- 12(77.4 cm2) square inch adhesive contact with the underside of the tile. Nail throu,npU:ricmmerw Medium Profile/Double Pan Tile (when requIr441 �Iwtth) 1. Starting at the eave course, apply a minimum 2"(50.8 mm) x 10"(254 mm)x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown under the - ' pan portion of the tile closest to the overlock of the tile being set.Insure approximately 17 (109.7 cm2)— �"'" 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2"(50.8mm) . +, x 7"(177.8 mm)x 1" (25.4 mm) foam paddy onto the = cwn, underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2)- 14 (90.3 cm2)square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 14-0805.01 I CMLAMI.DADfiCOUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 7 of 11 ADHESIVE PLACEMENT DETAIL#2 (CONTINUED) ► aticc* awt � � � High Profile/Single Pan Tile 1. Starting at the eave course, apply a minimum 2"(50.8 mm)x 10"(254 mm) x 1" (25.4 mm)foam paddy onto the underlayment positioned as shown under the • `,' ' ., pan portion of the tile closest to the overlock of the the being set. Insure approximately 17(109.7 cm2)— .,� � ; 23 (148.4 cm )square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2"(50.8mm) + x 7"(177.8 mm)x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the panw, .o portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2)- 19 (122.6 cm2)square inch adhesive contact with the underside of the tile. NOA No.: 14-0805.01 MIAMI•DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 8 of 11 ADHESIVE PLACEMENT DETAIL#3 full dwomp plasdc cemew Pae Ebefteen Meg #wheareWi►ea► 1. On the eave course only, apply a minimum 2" (50.8 eactensaptianal\ _ mm)x 10" (254 mm)x V (25.4 mm)foam paddy �. Paddy auni onto the underlayment positioned as shown,under skqtwddr the strengthening rib for flat tile or under the an an tap of tk g g P portion of the tile for low or hi file tile closest P high 4x411, to the Overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive 0° ZX41n. ` from blocking P the wee holes. Insure approximately 17-23 int(109.7-148.4 cm2)of 10 adhesive contact with the underside of the the Fascia - raveckowe 2. Apply a 4" (101.6 mm)x 4" (101.6 mm)x 1" (25.4 mm)foam paddy onto the underlayment just below RaVLaw Proft Tile the second course line positioned foam paddy under the strengthening rib for flat tile, or under the Mail dhrou,paasdcaenww Sh*epa*fyvndwt1e pan portion of the tile, closest to the underlock for igen requiresq Pa+drtnetwweenUtesi the second course tile to be installed. Insure approximately 8-9 int(51.6-58.1 cm2) of adhesive Banens xtunduMel contact with the underside of the tile. aptlonal it �pad of c� (Instructions continued on nextpage) gg mix 4 x 4�. Si"ngt lxpad 4 ztn. Eave Uesare Eave[aurse Fascia Medium lrotileTlio NOA No.: 14-0805.01 Q•DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 ADHESIVE PLACEMENT DETAIL# 3 (CONTINUED) MA thmuo plank Sir4e I�7 Odder tft iaitenrewwecq 3. Also apply a 2" (50.8 mm)x 4" (101.6 mm)x 3/4" PadaYitaet>w�ac►tltest (19 mm)paddy on top of the eave course tile Battens nadaY Innaertliei surface as shown, on top of the strengthening rib for flat the or on top of the pan portion of the tile, closest to the underlock of the first course of tile. • Install second course of tile. Insure approximately on PP Y 4x4tn. 9(58.1 cm2)- 11 (71 cm2) square inch adhesive contact with the underside of the tile at the overlap Skoe :a , ddya and 7 (45.2 cm2)-9 (58.1 cm2)square inch top oftie adhesive contact with the underside of the the at the head of the tile. Continue in same manner. Earn Coarse—a fasda Weephow Easedoswe to ZIn. Drip edge High Profile Tne NOA No.: 14-0805.01 MIAMI•DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Two Piece Barrel(Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" t)Placa enough adhesive to achieve 65 to 70 sq in. Steep papplications foam In contact with the pan tile. when required) ired) (5 0.8 mm)1 x 10"(254 mm1 J x 1" (25.4 mm) 2)Tum coven upside down,Place adhesive In paddy onto the underlayment positioned as tat in.from outside edge of cover tile. shown under two adjacent pan tiles. Support eave Then install the tile.Ensure 20 to 25 sq.in.contact"a. .° tiles from rocking until adhesive has a chance to underlayment cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2)—70 (451.6 cm) y square inch adhesive contact with the underside Sheathing of the pan tile. Eave closure c (motarshown) 3. Turn covers upside down exposing the underside Weephole of the tile.Apply a minimum 1" (25.4 mm)x 10" Fascia Board (254 mm)bead of adhesive directly on the inner liamovatopportion ofthe*eve course cavartilo.Abuttosecond course of edge of each side of the cover tile. Leave pan tiles.Ensure earve end of pan and cover tiles are flush at*ave line. approximately 3/4"(19 mm)to 1" (25.4 mm) Two Piece Barrel-High Profile Tile from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course.Insure a minimum of 20(129 cm2) -25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2"(50.8 mm)x 4"(101.6 mm)nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 14-0805.01 MIAMI•DADECOUNTY Expiration Date: 05/10/17 IIIIIIII •••� � ■ p Approval Date: 09/04/14 Page 11 of 11 MIAMI. MIAMI-DADE COUNTY DEPARTMENT OF PERMITTING,ENVIRONMENT,AND REGULATORY AFFAIRS(PERA) PRODUCT CONTROL SECTION BOARD AND CODE ADMINISTRATION DIVISION 11805 SW 26 Street,Room 208 Miami,Florida 33175-2474 NOA T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE www.miamidade ov/Hera Boral Roofing,LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County PERA -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County)and/or the AHJ (in areas other than Miami Dade County)reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#07-0220.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMI•DADE COUNTY NOA No.: 12-0222.02 �� ""' ' Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Cateeorv: Roofing Sub-Cateeorv: Roofing Tiles Material: Concrete Deck Type: Wood I. SCOPE This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barcelona 900 1= 17" TAS 112 High profile, interlocking, one-piece, 'S' w= 13" shaped, high-pressure extruded concrete roof ''/z" thick tile equipped with three nail holes. For direct deck or battened nail-on,mechanically fastened,mortar set or adhesive set applications. Trim Pieces Length: varies TAS-112 Accessory trim, boosted Barcelona, concrete Width: varies roof pieces for use at hips,rakes,ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales,FL. 2.2 SUBMITTED EVIDENCE: Test Aeencv Test Identifier Test Name/Reyort Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix 111 TAS 102 &TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix 11 TAS 108(Nail-On) Redland Technologies P0402 Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail-On) MIAMI•DADE COUNTY NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 2 of 7 Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Professional Service Industries, 1C-1320-94 Physical Properties Feb. 1995 Inc. TAS 112 The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996 Engineering, Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996The Center for Applied 25-7688-5 Static Uplift Testing June 1996 Engineering, Inc. TAS 102 (3" Headlap,Nails, Direct Deck,New Construction) The Center for Applied 25-7688-4 Static Uplift Testing June 1996 Engineering, Inc. TAS 102 0" Headlap,Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering, Inc. Evaluation 25-7183 March 1995 Calculations Walker Engineering, Inc. Evaluation 25-7094 February 1996 Calculations Walker Engineering, Inc. Evaluation 25-7496 April 1996 Calculations Walker Engineering, Inc. Evaluation 25-7584 December 1996 Calculations 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 122 TAS 112 January 2007 MIAMI-RADE COUNTY NOA No.: 12-0222.02 ������� ••�f Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 1 12, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Barcelona 900 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -X (ft) Tile X(ft ) (ft ) Profile Batten Application Direct Deck Application Barcelona 900 0.289 0.313 Table 3: Restoring Moments due to Gravity - M9 (ft-Ibf) Tile 2":12" 3":12' 4":12" 5":12" 6":12" 7"•12" or Profile greater Barcelona Battens Direct BattensDirect Battens Direct Battens Direct Battens Direct Battens Direct 900 Deck D ck Deck Deck Deck Deck 7.28 8.13 7.21 8.0 7.10 7.93 6.96 7.78 6.79 7.61 6.61 7.40 NOA No.: 12-0222.02 MIAMI-DADECOUNTY Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Nail-On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19/32" plywood) plywood) Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 1-10d Smooth or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1 48 Screw 20.7 20.7 18.1 2 48 Screws 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail 23.1 23.1 19.0 Field Clip) 1-10d Smooth or Screw Shank Nail 29.3 29.3 24.0 Eave Clip) 2-10d Smooth or Screw Shank Nails 27.6 27.6 38.6 Field Clip) 2-10d Smooth or Screw Shank Nails 38.1 38.1 41.8 Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mf(ft-Ibf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Adhesive 29.3 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 10.7 grams. Polyfoam Product, Inc.Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Barcelona 900 Polyfoam Pol Pro TM 66.5 Polyfoam Pol Pro TM 38.7 3 Large paddy placement of 63 rams of Pol Pro TM 4 Medium paddy placement of 24 rams of Pol Pro T^° Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-Ibf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Barcelona 900 Mortar Set 24.5 5. Tile-Tite Roof Tile Mortar NOA No.: 12-0222.02 �♦ � MIAMI-DARE COUNTY Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 5 of 7 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". I@ LABEL FOR BARCELONA 900 TILE(LAKE WALES FL PLANT 2) LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0222.02 M'i orwe couNrr Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 6 of 7 PROFILE DRAWING NAIL HOLES OVERLOCK 33 5/8" 17 13 UNDERLOCK v BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 12-0222.02 MMMMDADE COUNTY Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 7 of 7 1/27/2015 9: 40 AM FROM: 7276667638 TO : 3057568972 P. 2 Date CERTIFICATE OF LIABILITY INSURANCE 1/27/2015 Producer: Plymouth Insurance Agency This Certificate is issued as a matter of information only and confers no 2739 U.S. Highway 19 N. rights upon the Certificate Holder. This Certificate does not amend,extend Holiday, FL 34691 or alter the coverage afforded by the policies below. (727) 938-5562 Insurers Affording Coverage NAIC# Insured: South East Personnel Leasing, Inc. 8r Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Insurer B: Holiday, FL 34691 Insurer C: Insurer D: Insurer E: Coverages hepo icies of insurance listed below have been issue to the insured named above for the policy period indicated_ Notwithstanding any requirement,term or condition of any contract or other documert with respect to which this certificate may be issued or may pertain,the insurance afforded by the policies described herein is subject to all the terms,exclusions,and conditions of such policies. Aggregate limits shown may have been reduced by paid clams. INSR ADDL Policy Effective Policy Expiration LTR INSRD Type of Insurance Policy Number Date Date Limits (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Each Occurrence $ Commercial General Liability Damage to rented premises(EA Claims Made 11 Occur occurrence) Med Exp $ General aggregate limit applies per: Personal Adv Injury Policy 11 Project ❑ LOC General Aggregate Products-Comp/Op Agg $ AUTOMOBILE LIABILITY Combined Single Limit Any Auto (EA Accident) $ All Owned Autos Bodily Injury Scheduled Autos (Per Person) Hired Autos Bodily Injury Non-Owned Autos (Per Accident) Property Carnage (Per Accident) $ EXCESS/UMBRELLA LIABILITY Each occurrence Occur 0 claims Made Aggregate Deductible A Workers Compensation and WC 71949 01/01/2015 01/01/2016 X I WC Statu- OTH- Employers'Liability tory Limits ER Ary proprietor/partner/executive officer/member E.L Each Accident $1,000,000 excluded? NO If Yes,describe under special provisions below. E.L.Disease-Ea Employee $1,000,000 E.L.Disease-Policy Limits $1,000.000 Otter Lion Insurance Company is A.M.Best Company rated A-(Excellent). AMB# 12616 Descriptions of Operations/Locations/VehicleslExclusions added by Endorsement/Special Provisions: Client ID: 93-68-001 Coverage only applies to active employees)of South East Personnel Leasing,Inc.&Subsidiaries that are leased to the following"Client Company": J.M.Roofing Professionals,Inc Coverage only applies to injuries incurred by South East Personnel Leasing,Inc.&Subsidiaries active employee(s),while working in:FL. Coverage does not apply to statutory employee(s)or independent contractor(s)of the Client Company or any other entity. A list of the active employee(s)leased to the Client Company can be obtained by faxing a request to(727)937-2138 or by calling(727)938-5562. Project Name: ISSUE 01-27-15(MT) CERTIFICATE HOLDER CANCELLATION Bin Date 1/20/2014 CITY OF MIAMI SHORES VILLAGE Should any of the above described policies be cancelled before the expiration date thereof,the issuing BUILDING DEPARTMENT insurer will endeavor to mail 30 days written notice to the certificate holder named to the left,but failure to 10050 N.E.2ND AVE do so shall impose no obligation or liability of any kind upon the insurer,its agents or representatives. MIAMI SHORES VILLAGE, FL 33138 �, � BUILDERS GROUP, INC. GLOBAL Email: gbgRoofing@gmail.com Licensed & Insured 18724 NW 47 Place - Miami, FL 33055 LIC CCC 1329597 Cell: 305-726-8711 • Office: 305-964-7100 Submitted tot Fhonet Address: .lob II DAM" i city stetempCodec Job Address: i WE HEREBY SUBMIT THE FOLLOWING ESTIMATE AND CONTRACT SPECIFICATIONS RE-ROOF � `'"NEW ROOF RE-COVER SHINGLES TILE FLAT METAL Roof Type: PITCHED Sq.Ft FLAT Sq.Ft Deck Type: WOOD V CONCRETE GYPSUM Ridges Cap: Ridge Vents _ Parapet COMMENTS: SCOPE OF WORK Remove existing roofing materials down to the roof deck and dispose of all debris. Replace damaged wood at deck up to 100 Lineal,Feet or three sheets of plywood,anything over will be charged as follows: Sheathing or fascia board$2.50 p/Ft.Bcams:$5.00 p/Ft. $100.00 per piece(covers 32 SQ.FT.if the usage is less,it would be reduced from the last 30%payment. Prepare roof surface by sweeping and cleaning to Install the following materials: One layer of#30 base felt install with tin tabs corrosion resistant 6"on laps&12"o.c in the field. Vents or Lead sleeves Flashing around Vent Stacks with 1 %"ring shank nails sealed with plastic roof cement and membrane. :t x 3'26 gauge galvanized metal cave-drip nailed 4o.c along edge of roof. �16-26 gauge galvanized meta!at valleys as required. Mgtal flashing at intersection of roof-to-roof or roof-to-wall. + _M2 gauge galvanized stucco stop with fasteners sealed with caulking or plastic roof cement and membrane, PITCHED ROOF SHINGLE SYSTEM 3-Tab Fiberglass Shingle fungus/mildew resistance with 1 1/4"ring shank nails. Color. Dimensional Fiberglass Shingle funguslmildew resistance with 1 114"ring shank nails. Color. PITCHED ROOF TILE SYSTEM One layer of#W slate surfaces felt with mopped hot asphalt. Tiles with Foam Adhesive and/or roof Cement as per local codes requirements. Price shall be for standard tile and In stock. — Self attached underlayment FLAT ROOF BUILT-UP SYSTEM layer(s)of#75 base sheet with tin caps and fasteners. .Asphalt Primer thick Insulation roof levelling board with mopped hot asphalt. Cant Strip around parapet well with mopped hot asphalt. layer(s)of Fiberglass Ply IV with mopped hot asphalt. One layer of mineral surfaced CAP SHEET with mopped hot asphalt. One layer of modified RUSEROID with mopped hot asphalt. One layer of modified RUBEROID TORCH down system. Wall Flashing with mopped hot asphalt and termination bar sealed with plastic roof cement and membrane. All purpose Vents,Scupper and Pitch Pans where required. Self adhered system(Dade County Approved) TPO System REPAIR PITCHED OR FLAT ROOF Leak(s)located at: Prepare roof surface by removing existing roofing materials and dispose of all debris to install the following: Asphalt Primer layer(s)of#75 layer(s)of#30 Other as base. L Metal Flashing Stucco Stop Flashing Valley Metal Vents or Lead sleeve Flashing Turbines Sky Light. One layer of modified RUBEROID TORCH down system. Plastic roof Cement and Membrane as sealant. _ FIBERGLASS ply IV CAP SHEET_ModdW RUSERROIO GRAVEL*with mopped hot asphalt. !SHINGLES TILES One Coat of ALUMINUM PAINT. THIS JOB HAS A WARRANTY against faulty material and workmanship if maintained for a period of: PITCHED RE-ROOF: g Five Years 13 Seven Years Ten Years FLAT RE-ROOF: One Year Five Years Seven Years REPAIRS: Three Months [3 Six Months Q One Year NEW ROOF: One Year WE PROPOSE hereby to furnish materials and labor in accordance wjth a4ove specifications for the hum of: PAYMENTS to be made as follow: 1. 25%upon signing the contract 2. 35%upon commencement of job 3- 35%commencement of the second phew 4. 5% upon labor completion ACCEPTANCE OF CONTRACT: The above.pricez,specifications end are satisfactory and are hereby accepted..You are authorized to do the work as specified.Payment will be aQe}iS oudipid above.This proposal might be withdrawn by us if not accepted within Thirty days.The toted cost might vafjr,due constant increasing in material price.THIS PROPOSAL HAS THE POWER OF A CONTRACT WHEN`ACCEPTED AND SIGNED. ALL,PERMIT AND ENGINEERING OR ARCHITECTURAL F,-eS,.Alk,E NOT INCLUDED Authorized Signature Signature of r or owper's agent Date TERMS AND CONDITIONS 1. GLOBAL BUILDERS GROUP INC carries full insurance as required by Florida law, but shall not be held responsible for damages either before commencement of or during or after said work caused by strikes, wars,windstorm, hurricanes, a natural disaster, fire, hail, termites, or any event beyond our control. 2. GLOBAL BUILDERS GROUP INC does not guarantee against leakage due to the footwear, nor punctures, or penetration of the roofs integrity for the installation of an air conditioning unit, signs, hatchways, pipes or other structures, supports or brackets unless installed as a part of this contract. 3. GLOBAL BUILDERS GROUP INC does not guarantee against leakage due to improper roof building design, improper roof deck construction, nor to any kind of structural distress existing in the building that may cause ponding water and any other harm affecting the roof. In the event the building department requires tapered insulation to remove excessive ponding water, the customer will be charged for time and material only for the installation of said insulation and roofing. 4. GLOBAL BUILDERS GROUP INC reserves the right to discontinue this warranty due to any work performed on the roof by a tradesman or any parties other than those employed by this company. This warranty is not transferable. 5. In case a sealing is exposed and does not contain the necessary plywood to install the 1 'A ring shank nail, the customer will pay for the plywood necessary at an additional cost to meet the state code. 6. GLOBAL BUILDERS GROUP INC is not responsible for the damaged caused by any materials left on the roof if any natural disaster occurs. 7. GLOBAL BUILDERS GROUP INC will not be responsible for damages to sidewalks, fences, lawns, sprinkler systems, etc. that has been previously damaged where same must be crossed to gain access to building. 8. Due to nature of roofing work, on any job with exposed ceiling we strongly recommend the following be completed by the customer prior to our commencing of work: Cover furniture with a drop cloth. Remove from room or secure any loose and breakable items such as lamps, frames, fans, etc. because LOB„LBUI ERSuROIiPINC will not be held responsible for the damage of such mentioned items which occurred during length of job. Nor for punctums or penetrations of the air conditioning conducts installed close to the roof. Although we take all due care, GLOBAL BUILDERS GROUP INC can not be responsible for any dirt or small debO that might fall through sheathing of unexposed ceiling type of roofs, therefore there may be some clean up (vacuuming, dusting, etc.) required of the customer after completion of job. 9. Any unpaid balances shall void the guarantee of this contract. 10. In the event payment is not made as stored in specifications and if any sums are collected by suit or demand of an attorney or collections agency, then the undersigned agrees to pay all cost including assumable attorney's fees, court costs, and collection agency fees. 11. Return checks will be replaced for like amount plus any bank fees. 12. Any interruptions in the work which is in the fault of owner or owner's agent will be billed according to time and materials lost, and such cost shall be due and payable upon receipt of bill. 13. GLOBAL BUILDERS GROUP;INC will not be responsible for asbestos removal or surveys.And does not include cost of mechanical or engineering reports. 14. GLOBAL BUILDERS GROUP INC will not be responsible for maintenance items such as pitch pans and coaling. 15. Gutters: Especially seamless gutters should be removed by gutter company, before commencement of roof job, due care in avoiding damaged to existing gutters will be observed, however OLr,&;.BU! DERS GROOP.NC will not be held responsible for gutters. 16. Skylights. Existing skylights will be used, unless replacement is necessary it will be replaced at additional cost of skylights and labor only. 17. Owner shall provide GLOBAL BUILDERS GROUP iiz workers with running water and electrical power for their use at job site during length of job. 18. The shingle should not be painted under any kind of circumstance, and if painted the contract shall be null and void. 19. All materials are guaranteed to be as specified.All work to be completed in a workmanlike manner according to standard practices. 20. Any, AGWion or dp-v tionJr m abaue..specifications involving extra cost will be executed[Vnty upon written orders and will become an extra charge over and above the estimate. 21. Our workers are fully covered by workman's compensation insurance. 22. If damage is occurred by cleaning the roof with pressure cleaning machine, GLOBA.`uiLDERS GRCuP INC,' is not responsible for any kind of repair. 23. In case of a natural disaster and an increment in material and labor occurs; the prices wig increment in accordance. 24. GLOBAL BUILDERS GROUP!INC is not responsible for any kind of damage to the property by a truck or tradesman from supply or material delivering companies. 25.Anything not listed in this contract is excluded Initial Here— — ------------------------------------------------ South East Personnel Leasing, Inc. ----------------------------- Page: 1 ----- J.M. Roofing Professionals,Inc Check Date . : 01/16/1 1779 West 37th St., Hay #17 « Payroll Register >> Per End Date: 01/11/1. Hialeah, FL 33012 Batch Number: 666 P:: ------------------------------------------------------------------------------------------------------------------------------------ Employee Name Reg Hrs OT Hrs 0th Hr, Federal FICA State Other Check WkComp Pay Rate Regular Overtime Other Misc Inc Gross Pay Total Tax ---- Deductions ---- Net Pa, BRIZVELA, OSCAR B 4.00 2.47 292697 FL5551 8.05 32.20 - 32.20 2.47 29.7 CRUZ, JORGE LEONARDO 4.00 2.47 292697• FL5551 8.05 32.20 32.20 2.47 29.7 ---------------------------------------------------------------------------------------------------------------------------------- LOPEZ, DAVID J 4.00 2.47 292697. FL5551 8.05 32.20 32.20 2.47 29.7_ ---------------------------------------------------------------------------------------------------------------------------------- MOREJON, JUAN CARLOS 4C.CC i08.1.5 61.20 2.00CF 73.93CH 292697 FL5551 20.00 8c0.00 800.00 169.25 554.8: ------------------------------------------------------------------------------------------------------------------------------- MOREJON, MILENA S 40.00 55.46 42.08 452.461D 292697 FL8810 13.75 550.00 550.00 97.54 0.0 -------- ORTIZ, ROGELIO 4.00 2.47 292697 FL5551 8.05 32.20 32.20 2.47 29'7 ----------------------------------------------------------------------------------------------------------------------------------- URREA, EVELIO 0 4.00 2.47 292697 FL55SI 8.05 32.20 32.20 2.47 29.7 URREA, HUGO C 4.00 1.47 292698 FL5551 8.05 32.20 32.2C 2.47 29.7 Totals 3 00 104. n 163.51-FE 118.10-FT_6J 528.35*t CkS 8 1543.20 1543.20 281.61 733.2 Deductions 2.00 CF-Support Fee 73.93 CH-CHILD SUPPORT 452.46 1D-Direct Deposit 1 C I VI r9 L J.M. ROOFING PROFESSIONALS, INC. _ ( - 1779 WEST 37TH STREET. BAY#17 HIALEAH,FL 33012 Ph: (305)825-2128 . (305)825-7191 * Fax:(305)825.1569 Insured E-mail:jmroofmgpro@hotmail.com 'Your South Florida roofing expert" Lee.No.CCC1325770 PROPOSAL-CONTRACT Authorized Agent: Juan C. Morejon Submitted to: Phone: Date: ` � � f Address: yJob name:` City,State,Zip Code , , Job Address: 7 -7 =" ' _c, _� �1 .may .. ! O'✓ iaJ /Uy :� WE HEREBY SUBMIT THE FOLLOWING ESTIMATE AND CONTRACT SPECIFICATIONS —RE-ROOF NEW ROOF ✓ RE-COVER Roof T e: PITCHED.. /'JV ��` YP Sq.Ft FLAT f Sq Ft Deck Type: WOOD � CONCRETE GYPSUM Ridge Cap: Ridge Vents Parapet COMMENTS: SCOPE OF WORK — Remove existing roofing materials down to the roof deck and dispose of all debris. If more than one roof is found,it will be removed at an extra cost of$.50 per Square Feet. Replace damaged wood at deck up to 100 Lineal Feet or three sheets of plywood,anything over will be charge as follows: Sheathing or fascia board $2.50 p/Ft Beams:$5.00 p/Ft. — Prepare roof surface by sweeping and cleaning to install the following materials: — One layer of#30 base felt with tin tabs 6"on laps& 12"o.c in the field. Lead sleeves Flashing around Vent Stacks with 1 1/4"ring shank nails sealed with plastic roof cement and membrane. — 3"x 3"26 gauge galvanized metal eave-drip nailed 4"o.c along edge of roof. _ 16" 26 gauge galvanized metal at valleys as required. Metal flashing at intersection of roof-to-roof or roof-to-wall. - 26 gauge galvanized stucco stop with fasteners sealed with caulking or plastic roof cement and membrane. PITCHED ROOF SHINGLE SYSTEM _ 3-Tab Fiberglass Shingle fungus/mildew resistance with 1 1/4"ring shank nails. Color Dimensional Fiberglass Shingle fungus/mildew resistance with 1 1/4"ring shank nails. Color PITCHED ROOF TILE SYSTEM One layer of#90 slate surface felt with mopped hot asphalt. — Tiles with Foam Adhesive and/or roof Cement as per local codes requirements. Tiles shall be Prices shall be for standard tile and in stock. FLAT ROOF BUILT-UP SYSTEM layer(s)of#75 base sheet with tin caps and fasteners. Asphalt Primer METAL ROOF SYSTEM — thick Insulation roof leveling board with mopped hot asphalt or fasteners. _ Install a fire retardant membrane,versa shield elk Cant Strip around parapet wall with mopped hot asphalt. — Install a metal panels 1.5 versaloc metal panel 24 ga layer(s)of Fiberglass Ply IV with mopped hot asphalt. —Neoprene boots with ohime loc screw on all plastic pipe 7 - Y mopped One layer of mineral surfaced CAP SHEET with as Metal panel has 20 year limited warranty on substnate 1� hot asphalt. —(this is metal wa"amy rot our company wManty). _ One.layer of modified RUBEROID with mopped hot asphalt. — Metal panel has 25 year on kynar paint on panels — One layer of modified RUBEROID TORCH down system (this is WWI W"e"an"wt wr company warrmay). Wall Flashing with mopped hot asphalt and termination bar sealed with plastic roof cement and membrane. — All purpose Vents,Scupper and Pitch Pans where required. _ REPAIR PITCHED OR FLAT ROOF — Leak(s)located at: _ Prepare roof surface by removing existing roofing materials and dispose of all debris to install the following: , — Asphalt Primer layer(s)of#75 layer(s)of#30 Other *as base.. — L Metal Flashing _:Stucco Stop Flashing _Valley Metal _Vents or Lead sleeve Flashing _Turbines —Sky Light. _ One layer of modified RUBEROID TORCH down system. Plastic roof Cement and Membrane as sealant. _ FIBERGLASS Ply IV _CAP SHEET _Modified RUBEROID GRAVEL *with mopped hot asphalt. SHINGLES _TILES _One coat of ALUMINUM PAINT. THIS JOB HAS A WARRANTY against faulty materials and workmanship for a period of- REPAIRS: fREPAIRS: THREE MONTHS SIX MONTHS _ ONE YEAR PITCHED RE-ROOF: FIVE YEARS SEVEN YEARS TEN YEARS FLAT RE-ROOF: ONE YEAR FIVE YEARS SEVEN YEARS PITCHED OR FLAT NEW ROOF: ONE YEAR RECOVER: ONE YEAR WE PROPOSE hereby to furnish mat, r als and labor in accordance with above specifications for the sum of: PAYMENTS to be made as follows: RE-ROOF&NEW ROOF: 10%upon acceptance. 45%upon commencement of job. 40%while job is in progress on flat roof/ to purchase and install Tiles or Shingles on pitched roof. 5%upon job completion. RECOVER&REPAIR: 50%upon commencement of job. 50%upon job completion. ACCEPTANCE OF CONTRACT The above prices,specifications and conditions are satisfactory and are hereby accepted. You are authori2ed to do the work as specified.Payment will be made as outlined above. This proposal might be withdrawn . by us if not accepted within Thirty days.The total cost might vary due to constant increasing in material price.THIS PROPOSAL HAS THE POR OF A CONTRACT WHEN ACCEPTED AND SIGNED. Authorized Signature Signature of-owner orowner's agent Dates. TERMS AND CONDITIONS 1. Any alteration or deviation from above specifications involving extra cost will be executed only upon writt n*y orders.and will become an extra charge over and above the estimate. 2. All material is guaranteed to be as specified. All work to be completed in a workmanlike manner according to standard practices. 3. In a exposed ceiling that does not contain the necessary plywood to install the 1 1/4"Ring shank nail,the owner will be responsible for the payment of such extra material. 4. The shingle should not be painted under any kind of circumstance,and if painted the contract shall be null and void. 5. Our workers are fully covered by workman's compensation insurance. 6. JM ROOFING PROFESSIONALS INC., carries full insurance as required by Florida law, but shall not be held responsible for damages either before commencement of or during said work caused by strikes, wars, windstorm,hurricanes, a natural disaster,fire,hall,termites,or any event beyond our control. 7. JM ROOFING PROFESSIONALS INC., is not responsible for the damage caused by any materials left on the roof if any natural disaster occurs. 8. In case of a natural disaster and an increment in material and labor occurs, the prices will increment in accordance. 9. JM ROOFING PROFESSIONALS INC does not guarantee against leakage due to footwear, nor punctures or penetration of the roof's integrity for the installation of an air conditioning unit, signs, hatchways, pipes or other structures, supports or braces unless installed as a part of this contract. 10. JM ROOFING PROFESSIONALS INC. does not guarantee against leakage due to improper roof building design, improper roof deck construction, nor to any kind of structural distress existing in the building that may cause pounding water and any other harm affecting the roof. In the event the building department requires tapered insulation to remove excessive pounding water,the customer will be charged for time and material only for the installation of said insulation and roofing. 11. JM ROOFING PROFESSIONALS INC., is not responsible for any damage on the roof as a result of using a pressure cleaning machine. 12. JM ROOFING PROFESSIONALS INC., reserves the right to discontinue this warranty due to any work performed on the roof by a tradesman or any parties other than those employed by this company. This warranty is not transferable 13. JM ROOFING PROFESSIONALS INC., will not be held responsible for damage to sidewalks, fence, lawns, sprinkler system, etc., that has been previously damaged where same must be crossed to gain access to building. 14. JM ROOFING PROFESSIONALS INC., is not responsible for any kind of damage to the property by a truck or tradesman from suppliers or material delivering companies. 15. Due to nature of roofing work, on any job with exposed ceiling we strongly recommend that the following to be completed by the customer prior to our commencing of work: Cover furniture with a drop cloth. Remove from room or secure any loose and breakable items such as lamps, frames,fans,etc.because JM ROOFING PROFESSIONALS INC., will not be held responsible for the damage of such mentioned items which occurred during length of job.Nor for punctures or penetrations of the air conditioning conducts installed close to the roof. Although we take all due care, JM ROOFING PROFESSIONALS INC. can not be responsible for any dirt or small debris that might fall through sheathing of unexposed ceiling type of roofs,therefore there may be some clean up(vacuuming,dusting, etc.)required of the customer after completion of job. 16.Any unpaid balances shall void the guarantee of this contract. 17. In the event payment is not made as stored in specifications and if any sums are collected by suit or demand of an attorney or collections agency, then the undersigned agrees to pay all cost including assumable attorney's fees,court costs,and collection agency fees. 18. Return checks will be replaced for like amount plus any bank fee. 19.Any interruption in the work which is the fault of owner or owner's agent will be billed according to time and materials lost,and such cost shall be due and payable upon receipt of bill. 20. JM ROOFING PROFESSIONALS INC., will not be responsible for asbestos removal or surveys, and does not include cost of mechanical or engineering reports. 21. JM ROOFING PROFESSIONALS INC., will not responsible for maintenance items such as pitch pans and coating. 22. Gutters: especially seamless gutters should be removed by gutter company,before commencement of roof job,due care in avoiding damaged to existing gutters will be observed,however JM ROOFING INC. will not be held responsible for gutters. 23. Skylights: Existing skylights will be used, unless replacement is necessary it will be replaced at additional cost of skylight and labor only. 24. Owner shall provide JM ROOFING PROFESSIONALS INC., workers with running water. andelectrical`,, power for their use at job site during length of job. 25. JM ROOFING PROFESSIONALS INC., only covers in case of the leak, the repairs for the leak, and does not cover the ceiling,or any other damages to the property caused by the leak.