Loading...
RF-15-175Y s Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION BUILDING ❑ ELECTRIC 0 ROOFING FBC 201® Master Permit No —t5 f 5 1 215 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [:]MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 9330 NE 12 Ave City: Miami Shores County: Miami Dade Zia: Folio/Parcel#:11-3205-007-0160 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): John Mitchell Phone#: _;�o `D 150 oI iz) Address: 9330 NE 12 Ave City: Miami Shores State: FL Zip. 33138 Tenant/Lessee Name: NA Email: —`� - U3® q CONTRACTOR: Company Name: All Area Roofing & Waterproofing Phone#: 772-461-4706 Address: 3921 S US Hwy 1 City: Fort Pierce State: FL Zip: 34982 Qualifier Name: Charles Richard Phone#: State Certification or Registration #: CCC 1326177 Certificate of Competency #: DESIGNER: Architect/Engineer: Florida Engineering &Testing Inc Phone#: 866-781-6889 Address:250 SW 13th Ave city: Pompano Beach State: FL Value of Work for this Permit: $4849.00 Square/Linear Footage of Work: 475 Zip: 33069 Type of Work: ❑ Addition ❑ Alteration ❑ New ❑i• Repair/Replace ❑ Demolition Description of Work: Reroof flat roof back of house using tapered insulation and Firestone Ultraply TPO Specify color of color thru tile: rr`` Submittal Fee $ Jv � Permit Fee $c? �V OC CCF $ CO/CC $ Scanning Fee $ Technology Fee Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Bond $ i�;ac CK) \ TOTAL FEE NOW DUE $ 0L'D 4 • �V -�2q .ED rd Bonding Companys. Name (if applicable) Bonding CompanYs Address city State— Zip Mortgage Lender's Name Qf applicable) Mortgage Lender's Address Orty state Zip Application Is hereby made to obtain a permit to do the work and installations as indIcatecL I certify that no work or installation has commenced prior to the issuance of a permit, and that all work will be performed to meet the. standards of all laws regulating construction In this Jurisdiction. I understand that ateparate permit must be secured for ELECTRIC, PLUMBING4 SIGNS, POOM FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT* I certify that all the foregoing information is accurate and that all work Will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULTWtTH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING: YOUR NOTICE Of COMMENCEMENT ## Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $25M, ft applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be d0vered- to the person whose property is sWect to. attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days -after the building permit is issued. In the absence of such posted notice, the Inspection will not be approved and a reinspection fee Will be charged. Signature WNER or AGENT The foregoing Instrument,wasacknowledged before me this day of.a94N-i2f ji , 20 1J. by who Is persOnally known to me or o has prodtl;�'. as identification aodwho did take an oath. NOTARY PUBILIC* 90M, � M � Print: Signature / t7Z CONTRACTOR The foregoinginstru ent,wasiad"mnomvo4edopodBefore me.this: day of ZO by S 4wtials per Zhwhals personally known to me or�who•healwedticed as Identification and who did take an oath. NOTARY PUBLIC. Sign:_ Print :gw� State of Floft Seal: xV Seal: Notary Public, Commission Na EE 842238 Foe unmuui My commission Expires 111016"le ��/� APPROVED BY Plans Examiner Structural Review ,evisedOZ124/7014) SONIA DESTAFNEY MY COMMISSION #FF125420 EXPIRES May 21, 2018 Zoning Clerk 0110712015 11:03 All Area Roofing T0772 464 6600 P.0031003 STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-'1395 1940 NORTH. MONROE STREET TALLAHASSEE FL 32399-0783 RICHARDS CHARLES W ALL AREAR60FING & WATERPROOFING INC 25039 TRADEVMNDS DR LAND O' LAKES FL M39 Congratulationsl With this Iloense you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. ..•...• .. gvery,day_we Work to irrtprgv_e Ih@•Wpy we do business in order to _ serve you better. For informa$on about our services, please log onto www myfloridalicense.com. There you can And more information about our divisions newsletters adlaAaauttatteto dpartmsnt nom mo that he you, initiatives. Our mission at die Department is: License Efficiently, .Regulate Fairly. Wry constantlyy strive ta.serve you.betler so.that you•cve rr sa,-•:ytwr cuat4mers, .1-hnnk you for doing business in �Fiarida, and congratulations on your new IicinseE DETACH HERE RICK SCOTT, GOVERNOR STATE OF FLORIDA ' DEPARTMENT OF BUSINESS AND PROFE$SJUNADREGU LATION CCC1.326.177.._ •._ CERTIFIED ROOFING, CONTI7AG•` QIR RICHARDS, CH. ' ALL AREA ROOFING $ wATpkPROOFING I IS CERTIFIED under the provisions of Ch.489 FS. Expiration date .' AUG 84.2016 (,140 aw=eso KEN LAWSON, SECRETARY Smt: OF FLORIDA DEPARTMENT Or BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTIAN pingICTDV I lrmkicajez DAA On CCC1326177 The ROOFING CONTRACTOR Named below IS CERTIFIED unaer the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 RICHARDS, CHARLES W . ALL AREA ROOFING & WATERPROOFING INC 1820 N 57TH STREET ' TAMPA FL 33619 1SStiEM. 07/30/2014 DISPLAY AS REQUIRED BY LAW SEE# L14073OW01650 0110712015 11:03 All Area Roofing fAH0772 464 6600 P.0021003 1 2014 - 2015 HILLSBOROUGH COUNTY BUSINESS TAX RECEIPT EXPIRES SEPTEMBER 30, 2015 113152• OCC. CODE 5 Employees RENEW' 090.000004 Contractor Reeeipt Fee 18.00 Hazardous Waste Surch'arga 40.00 Law Library Fee 0.00 BUSINESS ALLAREA ROOFING & WATERPROOFING INC 2014 w 2015 1820 N 67TH ST TAMPA, FL 33619 NAME • ALL AREA ROOFING & WATERPROOFING INC MAILING 1820 N 57TH ST ADDRESS TAMPA, FL 336190000 Paid 13-655-000552 07/23/2014 58.00 BUSINESS TAX RECEIPT DOUG BELDEN, TAX COLLECTOR NA8 HEREBY PAID APR1VI6--- TAX TO EM3MF 813635-SnO N BUM"- PtW MIOA OR OCCUPAYWN SOIPIEO HEREON THIS BECOMES A•TAX RECEIPT WHEN VAUDAT01). • 0112712015 09:51 All Area Roofing f4772 464 6600 P.0011002 �cotzo� CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDIYYYY) 01/07/2015 THIS CERTIFICATE IS ISSUF_U AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS ,CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the polioy, certain policies may require an endorsement A Statement on this certificate does not confer rights to the certificate holder In Ilau of such endorsement(s). PRODUCER N A Bouchard Insurance for WBS PN' P.O.BOX 6090 PHOONE 868 29$--1$00 on 623 PAX MC No Clearwater, FL 33758.6090 ADDRED ESS. INSURED Workforce Business Services, Inc. Alt. Emp; All Area Roofing a Waterproofing Inc 1401 Manatee Ave. West Ste 600 Bradenton, FL 34205-6708 COVERAGES CERTIFICATE NI IMSER• 14FI ME— P12-7 R1=.Y I'IVN NUwilcir t= THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPHCT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED MER51N IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILT,NS, TYPE OF INSURANCE na POLICY EFF P E7fP POLICY NUMBER MM1D MMIDD L1MITS COMMERCIAL GENERAL LIABRM CLAIMS -MADE FIOCCUR EACH OCOURRENCE S PDAMAGE TO RENTbrj $ MED EXP one person) $ �--'� PERSONAL A ADV INJURY $ t:,EN'LAGGI:EGATELIMITAPPLIESPER: POLICY 1:1260y D LOC OTHER: GENERAL AGGREGATE $ PRODUCTS -COMPIOPAGO $ $ AUTOMOBILE LIABILITY ANY AUTO A � N1:0 AM LED HIREDAUT08 QED (11MIIN SINGLE LIMIT Ea aeGidenl $ BODILY INJURY (Perperson) $ BODILY INJURY (Perscaldsnt $ PROPERTY GE Perseaden $ �► EXCESS LIAB E%CESSLWB OOCUR CLAIMS -MADE NIA I WC 90.00 818-04 12131/2014 12/31!2015 EACHOCCURRENCE $ AGGREGATE S DED RETENTION $ WORKERS COMPENSATION AND 11MPLOYERS' LIABILITY ANY PROP EMBER EXCLUDED? CUTri/E YIN OFFICER/M n NH) EXCLUD®p (Mel>eately b Nnd If desr[ibe under DESCRIPTION OF OPERATION$ below $ x P T E.L. EACH ACCIDENT 8 1,000,000 E,L ais6ASE - EA l:pgP1 oYE $ 1,000,000 E.L. DISEASE •POLICY LIMIT $ 1,Ot)0,000 Location Coverage Period: 12/31/2014 12131/2015 Client# 054166 =OMP ON, OP OPERATIONS I LOCATIONS I VEHICLES (ACORD 101, Additional Remarks Schadula, may be allarhed If Mefe space Is "Ulred) Covsragc is provided for All Area Roofing & Waterproofing Inc LicenSC CCC1326177 only those 10•employeea 1820 N. 57th Street of, but not subcontractors Tampa, FL 33619 to: CFRTiMf'ATR uni nee Miami Shores Villaeg Building Dept 10050 NE 2nd Ave Miami Shores, FL 33138 AAASR /• SHOULD ANY OF 7MIc AMOVE bESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS, AUTHORIZED REPRESENTATIVE ----- -- •-.. •�... •. 1116' „wRv name ana 1090 are 1`e91S[817e0 marks of ACORD 01/2712015 09:51 All Area Roofing TAX)772 464 6600 P.0021002 ALLAREA-01 BROWND "�ti " CERTIFICATE OF LIABILITY INSURANCE DATE(MMIDD/YYYY} 1812015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER, THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the pollcy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to thtd terms and conditions of the policy, certain policies may require an endorsement A Statement ort this certificate do" not Confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Insurance Office of America, Inc. CONTACT Cathy Lewis PHONE Arc NoEA : (813) 637-8677 a10 No : 813) 637-8484 4916 West Cypress Street Tampa, FL 33607 ADDRESS: Cathy.L@%(isffioausa.com INSUREP431 AFFORDING COVERAGE me 11 POLICY EXP INSURERAIFIrst Mercury Insurance Company 10657 INSURED A INSURER B: Plan Insurance Company 30945 INSUMRc:AIG Specialty Insurance Company 26883 All Area Roofing & Waterproofing, Inc. 1820 N. 57th Street Tampa, FL 33619 INSURER D: Travelers Property Casualty Insurance Company 36161 INSURER r:: INSURER F COVERAGES Ar= all lith ._ •'�"o KKVISION NUMBER: THIS IS TO Cl;RTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTMER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS THE TERMS, rN SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS, -POLICY LTR TYPE OF INSURANCE 3=7 NUMBER POLI EFF POLICY EXP LANI73 A X COMMERCIAL GENERAL LIABILITY CLAIMS -MADE T OCCUR X MACGL000000732"S 03/1212014 03/12/2015 EACH OCCURRENCE S 1,000,0001 X Residential Ai Endt PREMISES Esaa,rrenes $ 60,00 MED EXP (Any ane per5pn} � PERSONAL & ADV INJURY $ 1,000,000 GEML AGGRECIATE LIMITAPPUES PER GENERAL AOGREOATE $ 2,000,000 POLICY Qj R0 ❑ LOC EECC PRODUCTS -COMP/OPAGO $ 2,000,00( OTHER' COMBINED SINGLE LIMIT S Ea accident 11000100 B AUTOMOBILE 11AIWILAY X ANY AUTO AUTOS ED PALGM100045500 03/25/2014 03/25/2015 BODILY INJURY (Per penin) $ BODILY INJURY (Per uddent) S ASCCHH¢DULED FARED AUTOS NON -OWNED PROPERTY DAMA©E S Per accIdea AUTOS UMBRELLA LIAR XPIP OCCUR $ 10,00 C X ElLtess LIAR CLAIMS -MADE 043707329 03/12/2014 03112!2015 EACH OCCURRENCE $ 6,000,000 DED RETENTION S AGGREGATE $ 6,000,00( WORKERS COMPENSATION S AND EMPLOYERS LIABILITY SFTE E EOR TNEECUTIVE YIN ANY PROPRIeroPJPARRIEX OFFICER/MEMBER EXCLUDED? ❑ N 1 A EL, EACH ACCIDENT $ enstdtorylnLinder NH) If EL.DISEASE -EAEMPLOYEE $ DPB8 PT�10 OF OPERATIONSbetow b Leased/RentedEqulp. E,L,DISEASE- POLICY LIMIT $ QT6608A380577TILI4 10/21/2014 I IW2112015 Ded. $1,000 70 000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACCRD 101, A0419ml Remarks Sahadulo, may bo Attached It mora space Is m"Imd) # CCC1326177 Miami Shores Village Bldg Dept is an additional insured in regards to the General Liability when required in a written contract. CERTIFICATE HOLDER Miami Shores Village Bldg Dept 10050 NE 2nd Ave. $MOULD ANY OF TME ABOVE bF-SCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE —'o a &vrY r�a.VMLJ %,UmrVKA I IVN. All rights reserved. ACORD 25 (2014101) The ACORD name and logo are registered marks of ACORD ME : f: Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components and Identify Manufacturer (if a component is not used, identify as "NAI System Manufacturer: Firestone Building Products NOA No.: 12-0307.02 Design Wind Pressures, From RAS 128 or Calculations: Pmax1:-40.1 Pmax2: -67.3 Pmaxs: -101.3 Max. Design Pressure, From the Specific NOA System: -60 Deck: Type: wood T$G Gaugerrhic mess: 19/32 or greater Slope: Flat Anchor/Base Sheet & No. of Ply(s): na Anchor/Base Sheet Fastener/Bonding Material: no Insulation Base Layer: Tapered ISO Base Insulation Size and Thickness: 1.50" to 3.06" Base Insulation Fastener/Bonding Material: Ply aftwhW min of (5) HD smears & T ft=Wr M Ma fates per 4•8 Top Insulation Layer: NA Top Insulation Size and Thickness: NA Fastener Spacing for Ancko_rMawSheet Attachment ; �a,1 e ? k -,j ,me tm b r& n Field: 6 " 5.5" 90" n OC @ Lap @ OC Perimeter: 6 ° 78" a jflowrs 5.5" oc Lap, @ oc n n b Comer: ° oc @ ap,iffyRo 5.5 �oc Number of Fasteners Per h sulatloA... Board •••••• • ...... . .fees. 2 2 ssssG• 20 Field: Perimeter Comer • • • -&- &.0 0600 aeaea0 fee a Illustrate Components Hilted and ' •: 06000 000000 e Details as Applicable: ; • •; •;0 • Woodblocking, Gutter, Edge 6 Terroj,► Vlhp, • Goes % Stripping, Flashing, ContiluouS• Cleat, Cant :0000: Strip, Base Flashing, COUnter- lasbhV, 0 • Coping, Etc. • • • Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. 1 Height Top insulation Fastener/Bonding Material: L3 I } cme 14 ��( NA na M Base Sheet(s) & No. of Ply(s). NA 3 rr Tcpe Md 'D-1-0 FT. Mean Base Sheet Fastener/Bonding Material: ivoo C4 NA Roof Height Ply Sheet(s) & No. of Ply(s): NA 10 Ply Sheet Fastener/Bonding Material: NA Top Ply: Ultraply TPO Top Ply Fastener/Bonding Material: etestmre heavy d*fastma ami HD Seam plates 2-W dwrowMW weld Surfacing: na MMM1MLWW1—dL"M1 DATE: 1/23/15 CLIENT: All Area Roofing ENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 www.floridaengineeringandtesting.com 250 S.W.13ta Avenue Pompano Beach, FL 33069 JOB ORDER #: 15-295 ADDRESS: 3921 S. US Highway 1 Fort Pierce, Florida 34982 PROJECT: Mitchell Residence Flat Wood Roof Deck ADDRESS: 9330 N.E. IP Avenue Miami Shores, FL FBC 2010/ASCE 7-10 DESIGN PRESSURE CALCULATIONS"". GCP1 = -1.0 2) . . .... ...... 3) GCP3 = -2.8 ...... . ....% Proiect Information: • Height = <15' Exposure: C Basic/Ultimate Wina-Speed: AKU--f5 mpla•: • 9 Length = 25' Category: III •6669• 6• Nominal Wind SpeeA0Y. d=Vuit N. • ..... • • •. • Width = 19' Slope: < 7 (asd = allowable strict litiesign) ' '. . . . 6966• • Parapet Wall: < 3' Residential '•6' KZ = 0.85, Kzt = 1.03 Kj 0.85: 00060 :Goo*: •9 • Design Calculations: Velocity Pressure: q = 0.00256*KZKztKdV2 Velocity Pressure („ it): q=0.00256(0.85)(1.0)(0.85)(175)2] = 56.64 psf Velocity Pressure (asd): q=0.00256(0.88)(1.0)(0.85)(180*0.6)2] = 33.99 psf Width of Pressure Coefficient: 0.1(19') = 1.9' 0.4(15') = 6.0' } use: 3'0" Effective Wind Area: <lW For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) Q `V Quality j, A /§ ✓lssrcrance GCPi = 0.18 �1 Page 2,1/23/15, Job Order # 15-295 All Area Roofing Mitchell Residence - Flat Steel Roof Deck 9330 N.E. 12th Avenue; Miami Shores, FL: Design Pressures Based on Vasd: 1) Field P1 = 33.99*[( -1.0) — (0.18)] = -40.1 psf 2) Perimeter P2 = 33.99*[( -1.8) — (0.18)] = -67.3 psf 3) Corners P3 = 33.99*[( -2.8) — (0.18)] = -101.3 psf Attachment Requirements Per RAS -117: FILO A Based on the requirements of N.O.A. #12-0307.02, pg 4 of 8, with a maximum design pressure of-60psf, the following are our recommended fastening patterns to attach the proposed membrane sheet through the preliminarily fastened insulation to the tiyQp� insulated deck utilizing Firestone Heavy Duty Fasteners and 2-3/8" dlame*er Firestone HD Seam Plates: � 0 : :000:0 0000.. • Field: 6" o.c. @ 5.5" laps, in rows spaced @ a maximum of 90" or.... .. .... . 00 Perimeter: 6" o.c. @ 5.5" laps, in rows spaced @ a maximum of 7811609660 • 0000...00 Corners: 6" o.c. @ 5.5" laps, in rows spaced @ a maximum of 48" o.c* 00 0 .. . 0 .0. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" 00 Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). Sincerely, All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2010 Edition. Wind load calculations based on ASCE 7-10, FBC 2010 and information provided by client. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Reza Javiraan, P.K Florida Engineering & Testing, Inc. Florida Reg. No. 60223 Certificate of Authorization No. 6923 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. 0000.. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING -CONSIDERATIONS R44402.13.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the ownerw itth the required roofing permit, and to explain to the ownerthe content of this section. The provisions Section R4402 govern the minimum requirements and standards ofthe industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the tor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics -Workmanship: The workmanship provisions of Section 144402 are for the purpose of pmvidmg that the roofingsystern meets the wind resistance and water intrusion performance standards. Aesthetiss (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement twr n the owner and the contractor. • *see • 000 0000 2. iRenalfing Wood Decks: When replacing roofing, the existing wood roof may tia�r &be renailed in accordance with the current provisions of Section R4403. (The roof deck is tFconcealeq prior to wing the existing roof system.) • • • • • • • 0000 • •• 3. Common Roofs: Common roofs are those which have no visible dei eation•between neigh ring units (i.e. townhouses, condominiums, etc.) in buildings with common' left, the rooting co traVTr and/or owner should notify the occupants of adjacent units of roofing wor��bt performed. s• :000:0 • • • • • 4. Exposed Ceilings: . F�cposed, open beam ceilings are where the unders�le gf'1�e rodf decking can be Viewed from below. The owner may wish to maintain the architectural appeara rift, tlbreforg' r0ft nail penetrationsof the underside of the decking may not be acceptable. This provides the option of math4Wrft Vapce. Ponding Water: The current roof system and/or deck of the building. may not drain well and ater to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident u . "lth original' roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flaw off so _that the roof is not o e oaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to 'install overflow scuppers in a rd ce with the requirements of Sections R4402, R4403 and R"13. 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the Intenor of 1he structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. it may be beneficial to consider additional venting which can result in extending the service life of the roof. Exception: Attic spaces, designed by a Florida licensed engineer or registered architect to eliminate the attic venting, venting shall not required. // 10 , Date ISE 12 Ave Property Address Permit Number do A ///,?" 4 A Contractors Sl nature • 0000•. • NIA -DaADE' ` ` MIAMI DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208 AFFAIRS (PERA) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/vera Firestone Building Products Company, LLC 250 West 96h Street Indianapolis, IN 46260 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami --Dade ecougly) .... • • reserve the right to have this product or material tested for quality assurance purposes!'If;his pt%4i1e$•or •, material fails to perform in the accepted manner, the manufacturer will incur the e41ld bf suc'h testing and the AHJ may immediately revoke, modify, or suspend the use of such product of i$'al8fiai within'their :....: jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined bydVl1a�r�rn'-Dadj6 *Gq ttty • Product Control Section that this product or material fails to meet the requiremepts. p f .the appocallle . ; . • building code.' .. .. .. ...... This product is approved as described herein, and has been designed to comply with,the'Fjprida Building ....:. Code including the High Velocity Hurricane Zone of the Florida Building Code.•"0 • . ...... DESCRIPTION: Firestone UltraPly TPO Single Ply Roof Systems over Wood Decks. ' , . • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 12-0131.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 12-0307.02 Expiration Date: 04/19/17 Approval Date: 07/26/12 Page 1 of 8 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Single Ply Roofing Material: TPO Deck Tvpe• Wood Maximum Design Pressure -82.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product U1traPly TPO TPO QuickSeam Flashing Single -Ply QuickPrimer Primer EdgeGard System Dimensions Various 5-3/4" x 100' 1 gallon APPROVED INSULATIONS: Product Name ISO 95+ GL DensDeck, DensDeck Prime FiberTop E High Density Wood Fiberboard Georgia-Pacific High Density Roof Fiberboard Test Specifications TAS 131 ASTM D 6878 Proprietary Proprietary Various Various TABLE 2 Product Description Polyisocyanurate foam insulation Fire resistant rated gypsum Woodfiber insulation board Non -Asphaltic fiberboard Insulation Non Asphaltic fiberboard Insulation Product Description Reinforced TPO 0.045" to 0.080" thick membrane Flashing material with pre; • • • applied adhesive • 000000 Primer for TP© QtttickS" .:. Flashing • • • • • • 0000.. Flashing materials and • • • assemblies • • • • • • • 0000.. ... . 0000.. • • . M;m acturer 0 • (With Current NOAJ • • Firestone Building Products Co. Firestone Building Products Co. Firestone Building Products Co. Generic Georgia-Pacific APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Firestone Heavy Duty #15 Fastener for steel, N/A Firestone Building Fastener Wood, concrete decks Products Co. 2. Firestone All Purpose #14 Fastener for steel, N/A Firestone Building Fastener Wood, concrete decks Products Co. 3. Firestone 2-3/8" Barbed Membrane seam 2-3/8" Firestone Building Seam Plate attachment plate diameter Products Co. rr 0000 APPROVED NOA No.: 12-0307.02 Expiration Date: 04/19/17 Approval Date: 07/26/12 Page 2 of 8 0000.. 0000.. 0000.. 0000. 0000. 0000.. •.•••• APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 4. Firestone HD Seam Plate Metal Seam Plate with 2-3/8" Firestone Building Eyehooks diameter Products Co. 5. Firestone Pre -Assembled #14 w/insulation plate for N/A Firestone Building fastener & plate steel, Wood, concrete Products Co. decks 6. Pre -Assembled Heavy #15 w/insulation plate for N/A Firestone Building Duty fastener & plate steel, Wood, concrete Products Co. decks 7. Firestone Heavy Duty Plus Insulation and membrane Various Firestone Building Fastener fastener Products Co. 8. UltraPly TPO InvisiWeld High-performance TPO 3" diameter Firestone Bu4ditig • Plates membrane fastening : Praducts cd"' system :. •.: • 0000.. EVIDENCE SUBMITTED: 006.6. 6 6666 6 66 Test Aeency Test Identifier DescriAtioas 6 6 6 6 nate 6 6 - W 6 0000 .. Underwriters Laboratories Inc. 01NK17982 UL790 ;••;•; 06/05f'O1 OONK43467 UL790 • 0=01 99NK5401 UL790 : 6 09/17/99 99NK3276 UL790 0 0 03�3.00 ;. 98NK39140 UL790 05/13/99 03NK34486 UL790 03/22/05 IONK13003 UL1897/TAS 114-J 07/17/12 Factory Mutual Research 3006983 4470 02/08/00 Corporation 3004249 4470 11/03/99 3003830 4470 05/26/99 3001925 4470 05/24/99 3014031 4470 07/22/02 3014918 4470 12/17/03 3012931 4470 04/04/04 3016670 4470 04/29/04 3017120 4470 04/30/04 3020394 4470 09/03/04 3022988 4470 01/28/05 3019991 4470 09/20/05 Atlantic & Caribbean Roof Consulting, LLC ACRC 06-030 TAS 114-J 08/21/06 Trinity;ERD F8960.04.08 -R1 TAS 114-F 06/23/08 F8300.03.09 -R1 TAS 131/ASTM D6878 03/03/09 F8300.11.08 -R3 TAS 131/ASTM D6878 02/25/11 NOA No.: 12-0307.02 Expiration Date: 04/19/17 Approval Date: 07/26/12 Page 3 of 8 0000:0 6 000000 666666 6666. 00000 0000.0 000000 000000 6 0 APPROVED ASSEMBLIES: Membrane Type: Single Ply, TPO Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood attached to min. 2" x 4" supports spaced max. 24" with l Od nails spaced 4" o.c. at the perimeter of plywood and 8d nails spaced 6" o.c. at the field of plywood. System Type D: Membrane mechanically attached over preliminary fastened insulation. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ISO 95+GL Minimum 1.5" thick N/A N/A 0000 Top Insulation Layer (Optional) Insulation Fasteners • Fastener • • • • • • ; • (Table 3) Densitvm:. '. 66:66 6•• DensDeck, DensDeck Prime 906:60 Minimum 0.25" thick N/A • • N/A • • • • 0000 .. FiberTop E, Approved High Density Wood Fiber, Georgia-Pacific High Density RbUTiberbbar8' Minimum 0.5" thick N/A 6 6:6 6:N/A• 0 • • • • • 60 06 00 0060.6 Note: All insulation shall have preliminary attachment, prior to the installation QPf%efoofing . a membrane at a minimum application rate of five (5) HD screws and 3" diameter HD idulatiau6.:. 00600* 66'66 plates per 4' X 8' insulation board. Please refer to Roofing Application Standard 117 for � • • • • • • insulation attachment. • .. a Fire Barrier: None. Membrane: Firestone UltraPly TPO (45-80 mils) reinforced membrane attached to deck through the preliminary attached insulation as described below. Membrane is mechanically attached using Firestone Heavy Duty Fasteners and Firestone HD Seam Plates 2-3/8" diameter spaced 6" o.c. within minimum 5.5" wide laps. Laps are spaced maximum 90" o.c. and sealed with minimum 5" heat weld. Maximum Design Pressure: -60 psf (See General Limitation #7) NOA No.: 12-0307.02 Expiration Date: 04/19/17 Approval Date: 07/26/12 Page 4 of 8 GENERAL LIMITATIONS: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall ba•pia ed every 12' in each ribbon to allow cross ventilation. Asphalt application of eitbpr system sha11.1V at a minimum rate of 12 lbs./sq. • • ;...;. Note: Spot attached systems shall be limited to a maximum design pressurt UNM psf.' Fastener spacing for insulation attachment is based on a Minimum CharacteristiC.%We (F') ,Wue of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. I' &@ &tenet vW, as field-tested, are below 2751bf. Insulation attachment shall not be acceptable. -o:-,*: ••• • Fastener spacing for mechanical attachment of anchor/base sheet or membrane Atudh'ment is bascron a minimum fastener resistance value in conjunction with the maximum design vacua iieted withina specific system. Should the fastener resistance be less than that required, as detgarmiged by tte • • • • Building Official, a revised fastener spacing, prepared, signed and sealed by a Figgda registered... Professional Engineer, Registered Architect, or Registered Roof Consultant may be submittA aSaAl revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 12-0307.02 Expiration Date: 04/19/17 Approval Date: 07/26/12 Page 8 of 8 TGFU.R9516 - Roofing Systems TGFU.R9516 Page 1 of 50 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems FIRESTONE BUILDING PRODUCTS CO L L C R9516 250 W 96TH ST • INDIANAPOLIS, IN 46260-1316 USA• • • • sees •• References to Type GI and Type G2 ply and base sheets include "Type IV", "Type VI" (Type GI), "Ply IV (4) M" (TyI Gi)7"Ply Aro- 1toype • Gl), "MB Base Sheet M" (Type G2), "MB Base Sheet" (Type G2) in any of the following Classifications. "Firestone )MOV Shhr (Type G3) *000:0 may be used in lieu of any Type G2 base In any applicable non-combustible Classification. 000000 • • • sees•• "SBS Poly Base" Sheet can be used in any non-combustible deck system which utilizes a Firestone SBS cap. "ISOCbAV,*Rj:SISTA$% "IQ 300" • • are acceptable alternates to "ISO 95+" In any applicable Classification. • • • • e e • • • • • • "I.S.O.FIX Adhesive" may be used in any of the following Classifications to adhere insulation to the roof deck. 00:0*: ••• e i • • • • • of •s to "I. *sees* e S.O. Spray"° S" or "Firestone I.S.O. Stick", I.S.O Twin Pack and I.S.O Twin Pack Green may be used in any of tlle•Vg Wng ClassificWons to • adhere insulation to both non-combustible roof deck substrates and other insulation layers including wood fiberboard and 19-P Gypsum Corp. e "Dens -Deck@ Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuard1°° Roofboard.' s • • • •cess• • • • • • • "Tapered ISO 95+CAN" may be substituted for "ISO 95+CAN" in any of the systems listed below. "ISO 95+CAN" rfty tit' pfrforated on side :0000: jors for use as the contact side for BUR or modified bitumen membrane. e s s • ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A 1. Deck: NC Incline: 3 Insulation: — "ISO 95+FK", "GL", 'GVr or "Rhoflex Isocyanurate FK", "GL", "GW", any thickness, mechanically fastened or adhered with hot mopping asphalt. Ply Sheep — Two to four layers Type 15, GI or G2, any combination. Surfacing: — Gravel. 2. Deck: NC Incline: 3 Insulation: — "ISO 95+Composite", "Rhoflex Isocyanurate Composite" or "ISO 95+Wood Fiberboard Composite", mechanically fastened or adhered with hot mopping asphalt, 1.5 to 3.5 in. thick. Insulation (Optional): — Periite, 1 in. thick. Ply Sheet: — Three to four layers Type 15, GI or G2, any combination. Surfacing: — Gravel, slag or crushed stone. 3. Deck: NC Incline: 3 Base Sheet: — "MB Base Sheet", mechanically fastened or hot mopped. Insulation (Optional): — Any UL Classified (EPS must be covered with 1/2 in. thick min glass fiber, wood fiber or periite), any thickness, mechanically fastened or hot mopped. Ply Sheep — One or more layers "MB Base Sheet" or Type GI, any combination. Surfacing: — Gravel, crushed stone or crushed slag, in a flood coat of hot roofing asphalt. 4. Deck. C-15/32 Incline: 1 Insulation (Optional): — any UL Classified, any thickness. Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet" or "SBS Base - P" sheet, mechanically fastened or hot mopped, any combination. Membrane: — "SBS Smooth", "SBS Premium" or "SBS" (modified bitumen), hot mopped. Surfacing: — Gravel, crushed stone or crushed slag, in a flood coat of asphalt. S. Deck: NC incline: 1-1/2 Insulation (Optibnal): — any UL Oassified, any thickness. Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet" or "SBS Base P" sheet, mechanically fastened or hot mopped, any combination. Membrane: — "SBS Smooth", "SBS Premium" or "SBS" (modified bitumen), hot mopped. Surfacing: — Gravel, crushed stone or crushed slag, in a flood coat of asphalt. 6. Deck: NC Incline: 3 TGFU.R9516 - Roofing Systems Page 34 of 50 Barrier Board: — Regular or water resistant wallboard, 1/2 in. nom, joints in wallboard offset 6 in. with joints in deck. Insulation: — Celotex "Hy -Tec", "Energy -Loc", 'Thermax Hy -Tec Plus", 'Thermax Hy -Tec Plus II" or "Top -R-11", 1 In. min thickness. Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mil. 11. Deck: C-15/32 Incline: Unlimited Insulation (Optional): — Any UL Classified, any thickness. Barrier Board: — 1/4 in.thick GP Gypsum "DensDeck@ Roofboard" or "DensDeck DuraGuard— Roofboard" or "DensDeck Prime® Roofboard", mechanically fastened. Base Sheet: — One ply "SBS Premium Base Sheet" or "MB Base" or "Type IV M" or "Type IV M" or SBS Base Sheet" or "SBS Base P" sheet fully adhered with "Firestone Multii-Purpose Cold Adhesive" at 1-1/2 gaV100 ft2 Membrane: — One ply "SBS Premium FR" or "SBS Premium FR" cap sheet fully adhered with "Firestone Multii-Purpose Cold Adhesive" at 1-1/2 gal/100 fl? 12. Deck: C-15/32 Incline: Unlimited Insulation: — Firestone ISO 95+GL, any thickness Barrier Board: — G -P Gypsum DensDeck®, 1/4 in. Membrane: — Firestone UltraPly TPO" fully adhered with "UltraPly Bonding Adhesive", 1 gal/45 sq ft. 13. Deck: C-15/32 Incline: 1 Base Sheet: — One or more plies, "MB Base Sheet" mechanically fastened or hot mopped. Ply Sheet. — One or more plies "SBS Base Sheet" or "SBS Base P" sheet hot mopped. Membrane. — One or more plies "SBS Cap", hot mopped. 14. Deck: NC Incline: 1/4 Insulation: — Firestone ISO 95 + GL any thickness Membrane: — Firestone "UltraPly TPO XR 100" (45 mil), "UltraPly TPO XR 115" (60 mil) or TPO XR 135 (80 mil) adhered with Firestone ISO Spray S or XR Stick Adhesive full coverage 15. Deck: C - 7/16 -In. "CoverDX" Incline: 2 Membrane: — Firestone "Standard RubberGard (EPDM)", "Fire Retardant RubberGard 45," "60"; "FR EPDM" and "Triumph FR", "LS -FR RubberGard," "RubberGard MAX FR", EcoWhite 60 or 90 mil single ply membrane adhered with Firestone Modular Water Base adhesive -P 120 ft2/gal. 16. Deck: C - 7/16 -in. "CoverDX" Incline: 2 Membrane: — Firestone "UltraPly TPO" adhered with Firestone Water Base Bonding Adhesive 100 flz/gal. Class A - Mechanically Fastened The Insulation may be mechanically fastened to the deck with screws and metal or plastic discs, hot roofing asphalt or combination of screws/discs and hot roofing asphalt. As an alternate, the insulations may be used in combination to fulfill thermal barrier requirements but the total insulation thickness may not exceed the max insulation thickness of the classified assembly. The insulation is covered with one layer of "RubberGard", 45 or 60 mil EPDM membrane, mechanically fastened with one of the following methods: a. Firestone "RubberGard" Mechanically Anchored System (MAS) metal batten strips (not UL Classified) or "Firestone Plastic Batten Strip" and screws. "6 in. QuickSeam Batten Cover" may be applied over the batten strips. b. Firestone "RubberGard" Batten -In -Seam Mechanically Anchored System (MAS) metal batten strips (not UL Classified) or "Firestone Polymer Batten Strip" and screws. The above mechanically fastened systems shall be installed in accordance with the manufacturer's specifications. The EPDM lap splices are sealed with "SA 1065 Splicing Adhesive", "SA -1065 Splice Adhesive Plus" or "Triumph Splice Adhesive" (contact adhesive) aqp Cd at a rate of approximately 150 to 175 lin ft per gal (3 in. lap coated both mating surfaces) or 131 to 150 lin ft per gal 44 in. lapcoated both mating surfaces). The laps may also be sealed with "QuickSeam Splice Tape" (510/9/92A) or 'Triumph Sero Tope;, The edcleWthe *000:6 laps are sealed with a 3/8 in. by 1/4 in. bead of "LS -3029A1 ", "Lap Sealant HS" or "Triumph Lap Sealant" (M of 16p sealant with splice • tapes Is optional). Only Triumph Accessory Products are acceptable for use with Triumph EPDM membraner9F @4gne "Sinalt-�'+1jr • • • QuickPrime Primer", "Single Ply LVOC Primer" or "Royal BA2004T", "QuickPrime Plus LVOC", "QuickPrime" Qr "(�bickPrime Plus" may be • used with any Classified Firestone EPDM membrane assembly to prepare the seam area to receive any QuiWambroduct or SA -1065 • • Splice Adhesive and maintain the rating for that assembly. • • • • • • • • • Firestone "Single -Ply QuickPrime Primer" or "Single Ply LVOC Primer" or "Royal BA2004T", may be used wi9th any ClassifiedfFireMne TPO �; • 99 9999• QuickSeam Product. � 9 • •• •0• • � •• •• •• 9 9999•• Unless otherwise Indicated, the EPDM may be surfaced with "PC -100 coating" at 1 gal/sq with the option of appI in general purpose or • silica sand (sieve size 50 to 100) Into the wet coating at 35 Ib/sq. Membrane should weather approximateli•L v ie s prior to application • of the "PC -100 coating". • • • • • • • • • • •9000• Unless otherwise specified, the "UltraPly" membrane is mechanically fastened with large head metal or plastic fasteners spaced 18 in. OC ; • �; and max 2 in. from membrane's edge. Adjacent sheets are lapped 4 in., covering fasteners. Laps are heat Med 'Ultra PIX RPIM1.11, • • edges may be sealed with 1/4 in. bead of "WS6-TPO-3002". • • • "Nail Base" insulation is an acceptable alternate to all Insulations in the following Classifications. "Fire Retardant Reinforced" and "RubberGard MAX" EPDM membranes are an acceptable alternates to "Standard RubberGard", "FR RubberGard" and "Standard Reinforced RubberGard" in all applicable Classifications. http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=T... 9/23/2014 TGFU.R9516 - Roofing Systems Page 35 of 50 "Standard Reinforced RubberGard" and 'RubberGard MAX' EPDM membranes are an acceptable alternates to "Standard RubberGard" In all applicable Classifications. Pittsburgh Coming "FOAMGLAS" insulations are acceptable alternates to any polyisocyanurate insulation in any of the Classifications below. (Optional) Noncombustible deck Classifications ("FR RubberGard" systems excluded) are applicable for use over combustible (15/32 in. min plywood) decks when 1/2 in. (min) gypsum board or 1/4 in. (min) G -P Gypsum DensDeck ® are used directly over the deck with all joints staggered 6 in. (min) from plywood joints. "Triumph EPDM", 'Triumph Reinforced EPDM"'Triumph FR" and 'Triumph LS -FR° are acceptable alternates to Firestone "Standard RubberGard", Firestone "Standard Reinforced RubberGard", Firestone 'Fire Retardant RubberGard" and Firestone "-FFV, respectively, in all applicable Classifications. 1. Deck: NC Incline: 1/4 insulation (Optional): — Any combination of the following may be used: Perlite, wood fiber, glass fiber, 3 In. max. Insulation: — Wood fiber, 1/2 in. min. Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mil. 2. Deck: NC incline: 1/4 Insulation Concrete. — Deck covered with either of the following Insulating concretes (poured in place): cellular, vermiculite, perlite, gypsum or structural. Optionally, a base concrete deck may be used If all exposed surface joints are grouted. Insulation (Optional): — Wood fiber (Huebert), 1 in. max, or "FiberTop B", " FiberTop E", "FiberTop C" or "FiberTop S", asphalt side down, 1/2 in. max, "Rulon E3N". Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mil. 3. Deck: NC Incline: 1 Insulation (Optional): — any UL Classified, any thickness. Insulation: — Wood fiber (Huebert), 1 in., or "FiberTop B", " FiberTop E", "FiberTop C" or "FiberTop S", 1/2 in. min, asphalt side down. Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mll. Surfacing: — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied into the wet coating at 35 ib/sq. 4. Deck: NC Incline: 1/2 Insulation: — Atlas Roofing "ACFoam II ", Rmax "Thermaroof Plus -3", Rmax "Multi -Max -3", unlimited thickness. Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mil. Surfacing: — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied into the wet coating at 35 ib/sq. 5. Derdu NC Incline: 1/2 Insulation: — Atlas Roofing "ACFoam II ", any thickness. Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mil. Surftdng: — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied into the wet coating at 35 Ib/sq. 6. Deck: NC Incline. 2 Insulation (Optional): — Perlite, wood fiber or glass fiber, 3-1/4 in. max. Insulation: — Wood fiber (Huebert), 1 in. thick, or "FiberTop B", " FlberTop E", "FlberTop C" or "FiberTop S", 1/2 in. #44 min, asphalt side down. • • Membrane: — "Standard RubberGard" (EPDM), 45 or 60 mil. : •' • Surfacing: — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating"Vt 1 gEl/sq. OptionaN General purpose or silica sand (sieve size of 50 to 100) must be applied into the wet coating at 35 Ib/sq. 000000 0000• 7. Deck: NC Incline: 1-1/2 • 000.0• 0000 as • Insulation (Optional): — Polystyrene, polyisocyanurate, polyurethane, periite, glass fiber, wood flim V mo max tie cAsso Insulation: — Wood fiber (Huebert), 1 in., "FiberTop B", " FiberTop E", "FiberTop C" or "FiberTop•S;,VJ Ln. thick rnip, asghait side down. • • • e Membrane: — "Fire Retardant RubberGard" (EPDM), 45 or 60 mil. " • • • • 0000•• • 8. Deck: NC Incline: 2-1/4 • 0 • • • 0000•• Insulation (Optional): — Expanded or extruded polystyrene Dow Chemical "STYROFOAM RM, Pit sn Iro, LG" of "sTyRow, any thickness. • • • • 000 Insulation: — Wood fiber (Huebert), 1 in., or "FiberTop B", " FiberTop E", "FiberTop C" or "FiberTop S", 1/2 in. 040n,:asphait side down. Membrane: — "Fire Retardant RubberGard" (EPDM), 45 or 60 mil. 9. Deck: NC Incline: 1-3/4 Insulation: — Rmax "Thermaroof Plus -3", any thickness. (printed side down). Membrane: — "Fire Retardant RubberGard" (EPDM), 45 or 60 mil. 10. Devic NC Incline. 1 0000•• • • • 0000•• 0000•• • 0000• Goose •Gee•• • • 0800•• 0000•• • TGFU.R9516 - Roofing Systems Page 42 of 50 Insulation (Optional): — Any UL Classified, any thickness Insulation: — min. 1/2" "ISOGARD HD", min. 1" ISOGARD HD Composite Board or 1/2" Resista Membrane: — Standard RubberGard EPDM, mechanically attached Surfacing: — After the EPDM is allowed to weather for approximately two weeks, PC 100 Coating at 1 gal/sq. Optional General Purpose or silica sand (sieve size of 50 to 100) may be applied into the coating at 35 Ib/sq. 84. Deck: NC Incline: 1 Insulation (Optional): — Any UL Classified, any thickness Insulation: — min. 1/2" "ISOGARD HD", min. 1" ISOGARD HD Composite Board or 1/2" Resista Membrane: —Fire Retardant EPDM, mechanically attached Surfacing (Optional): — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied into the wet coating at 35 Ib./sq 85. Deck: NC Incline: 2-1/2 Insulation (Optional): — Any UL Classified, any thickness Insulation: — min. 1/2" "ISOGARD HD", min. 1" ISOGARD HD Composite Board or 1/2" Resista Membrane: — RubberGard Max FR, mechanically attached Surfacing (Optional): — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied Into the wet coating at 35 Ib./sq 86. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Firestone ISO 95+ GL, any thickness Insulation: — 1.0 Inch Minimum thickness "ISOGARD HD", 1 in. min. ISOGARD HD Composite Board or 1" Resista offset 6 inches with joints in the deck. Membrane: — Firestone LS -FR EPDM, RubberGard MAX, RubberGard MAX FR and Plantinum, mechanically attached. Surfacing (Optional). — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied into the wet coating at 35 Ib./sq 87. Deck. C-15/32 Incline: 1/2 Insulation (Optional): — Firestone ISO 95+ GL, any thickness Insulation: — 1.0 inch Minimum thickness "ISOGARD HD", 1 in. min. ISOGARD HD Composite Board or 1" Resista offset 6 Inches with joints in the deck. Membrane: — Firestone UltraPly TPO and RefiexEON TPO, mechanically attached 88. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Firestone ISO 95+ GL, any thickness Insulation: — 1.0 inch Minimum thickness "ISOGARD HD", 1 in. min. ISOGARD HD Composite Board or 1" Resista offset 6 inches with joints in the deck. Membrane: — Firestone Standard RubberGard, mechanically attached Surfacing: — After the EPDM is allowed to weather for approximately two weeks, "PC -100 Coating" at 1 gal/sq. Optional: General purpose or silica sand (sieve size of 50 to 100) may be applied into the wet coating at 35 Ib./sq 89. Deck: C-15/32 Incline: 3/4, See Note Slip Sheet: — Two layers "FR -10," mechanically fastened. Insulation (Optional): — Any UL Classified, any thickness (except EPS and wood fiberboard). Membrane: — Firestone EPDM or TPO membranes. (Note: Membrane must be currently Classified for use over the insulation used. Actual incline is determined by the maximum existing membrane/insulation Classification incline, but cannot exceed 3/4:12.) 90. Deck: C-15/32 Incline: 1/2 Insulation (O al): — Any UL Classified, any thickness, any combination. Insulatl= — 1 in. "Resista" Insulation M — Firestone 80 mil "UltraPly TPO". 0000 91. Deck: NC Incline: 1 • • • • 0000 •••0•• (Optional): —Any UL Classified, an Insulationy thickness, any combination. • • • • • • � 0000•• • Insulation: — 1/2 in. "Resists" Insulation Membrane: — Firestone 80 mil "UltraPly TPO". • 00000• • • • 92. Deck: C-15/32 Incline: 5 *0 0• 0, 00 0 0 0 0000 • •• 0000• Insulation (Optional): — Firestone "ISO 95+GL", any thickness. • • Barrier Board: — Minimum 1/4 in. thick G-13Gypsum "DensDeck® 0 0 i � 0 ' • 0 00000 Membrane: — "UltraPly TPO HS" 45-80 mil. so 00 so 00 0 0 0• • 93. Deck: NC Incline: 1-1/2• • • • • • • • •••••• 0000•• Insulation: — "ISO 95+GL", any thickness, mechanically fastened. 0 0' 0 • • 0 : 0 0 Membrane: — "UltraPly TPO HS", 45-80 mil. • 0 0 • • • • ; Class B - Mechanically Fastened 1. Deck: NC Incline: 3 http://database.ul.com/cgi-binIXYVItemplate/LISEXT/1 FRAMElshowpage.html?name=T... 9/23/2014 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date:`Ilk 1 `5 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: John Mitchell -C1 r. + r ®o'F \. Property Address: 9330 NE 12 Ave Roofing Permit Number: Dear Building Official: 1 John Mitchell building because: certify that I am not required to retrofit the roof to wall connections of my e The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code of 1994 edition of the South Florida Building Code (1994 SFBC) Orl Sig atur Print Name or with the provisions •••••• State of Florida 600:69 County of Dade • • • • The undersigned, being the first duly swom, deposes and says that he/she is the owner for th6.*Rv; Sworn to and subscribed before me this d, day of Notary Public, Sate of Florida at Large Notgry Public• •eotvinlon My Commission %7 .• 36 .•'..• :• • • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wag connection Hurricane Mitigation. Revised on 5121/2009