RF-15-134BUILDING
PERMIT APPLICATION
Miami Shores Village
Building Department �f
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
❑BUILDING ❑ ELECTRIC M ROOFING
FBC 20 10
Master Permit No. ?) E
Sub Permit No
❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL [—]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 117 NW 92 ST
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#:11-3101-033-1040 Is the Building Historically Designated: Yes NO
Occupancy Type: RES Load: Construction Type: Flood Zone: BFE: FFE:
OWNER: Name (Fee Simple Titleholder): AVERILL DORSETT Phone#: 305-799-1505
Address: 117 NW 92 ST
City: MIAMI SHORES State: FL Zip: 33150
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: ACEBO ROOFING CORP Phone#: 305-685-2534
Address: 4305 E 10 LANE
City: HIALEAH state: FL Zip: 33013
Qualifier Name: PEDRO ACEBO Phone#:
State Certification or Registration #: CCC058112 Certificate of Competency #:
DESIGNER: Architect/Engineer: N/A Phone#:
Address: City: State: -
Value of Work for this Permit: $ 7500. Square/Linear Footage of Work: 1351
Zip:
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑■ Repair/Replace ❑ Demolition
Description of Work: REROOF RESIDENCE FLAT ROOF ONLY WITH MODIFIED CAPSHEET
Specify color of color thru tile:
Submittal Fee $ Permit Fee $ 295 ` VQ) CCF $ CO/CC $
Scanning Fee $
Radon Fee $ DBPR $ Notary $
Technology Fee $ Training/Education Fee $
Double Fee $
Structural Reviews $ Bond $
(Revised02/24/2014)
TOTAL FEE NOW DUE $`",�b b a l�An
)i S b 106
Bonding Company's Name (if applicable) N/A
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable) N/A
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will nq be approved and a reinspection fee will be charged.
Signature- Signature
g g
OWNER or AGENT C0616Croll
The foregoing instrument was acknowledged before me this
day of 20 tea by
AVERILL DORSETT , who i ersonally kno to
me or who has produced
Identification and who did take an oath.
as
The foregoing instrument was acknowledged before me this
1-25 day of ZPk cgA2c=, , 20 lis . by
PEDRO ACEBO , who i ersonally know to
me or who has produced as
identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
Sign• Sia
Print: 4'- C-3asir---s Print:
PAOLA BASSI
Seal E!e,SY cy,,, PAOLA BASSI Seal: ; #: MY COMMISSION # EE 179098
t; :°*•. MY COMMISSION # EE 179098 , oQ EXPIRES: March 13, 2016
EXPIRES: March 13, 2016 Bonded 7hru Notary Public Undew tern
0 - � Bonded Thru Notarq Public Undenv tens
00✓ 0
APPROVED BY
(Revised02/24/2014)
Plans Examiner
Structural Review
Zoning
Clerk
CERTIFICATE OF LIABILITY INSURANCE
D01/12/2015
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT. If the aartiftcato holder is an ADDITIONAL INSURED, the policy (les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and Conditions
of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate hoklor in lieu of such
endorsemongs),
PRODUCER
FrankCrum Insurance Agency, Inc.
100 South Missouri Avenue
Clearwater FL 33756
CONTACT NAME:
PHONE AIC, No, Ext : 1.800-277.1820 x4800 FAX No 1., 2 797-0704
E -MALL ADDRESS
INSURERS) AFFORDING COVERAGE NAIGN _
INSURER A Frank Winston Crum Insurance Co. 11600
INSURED
FRANKCRUM LICIF ACEBO ROOFING CORP.
100 SOUTH MISSOURI AVENUE
CLEARWATER FL 33756
INSURER B
INSURER C:
INSURER D.
INSURER E:
INSURER F
VVYG.IWVGQ li K llrRA 1 C. NLMRnCK- SVnCVn WFVIli141N N"MRI w -
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAME ABOVE FOR THE POLICY PERIOD INDICATED.
NOTWITHSTANDING ANY REQUIREMENT, TERRA OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY
PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN
MAY HAVE BEEN REDUCED BY PAID CLAIMS.
RdSR
_..LTR.....
TYPE OF INSURTINCE
_........_.._,____. �_.
AML
INORD
SUeR
WVD
POLICYNUMBER
POLICY EFF
fmmolYYYY)
POLICY EXP
(MMOONYM
_.
GENERAL
LIAaRM
-
EACM OCCURRENCE
5
.
COMMERCIAL CEyERAL LIASRJTY
CLAIMS.StADE =OCCUR
DAMAGE TO RENTED
PREMISES Eu. mrt me
MED EXP (Any are patty)
8 -----
PERSONAL B ADV 24JURY
. 6_..___,
G2EM AGGREGATE
S
GENT AGGREGATE LIMIT APPLIES PER,
PROOUC75-COHP/OP AGC
8
PMICY r7 PR"CT MLOC
g
AUTOMOBRAUAaILITY
COMBINED SINGmuMrr
S
ANY AUTO
SODS.Y INJUpY Pm
9
ALL.OVOIED SCHEDULED
_
6000.Y INJURY(Pe aakWq
$
N
AUTOS AUTOS
..
HIRED AUTOS NON -OWNED
AUTOS
PROPERTY DAMAGE
ipw RWderol
...$
5
..
UMBRELLA LIARJ;;.—
EACH OCURREPICE
S
AGGREGATE
S
EXCESS 1.0
DED RETEAMON$
_-
S
A
KS SCOMIENSA
WORWORKERS COMPENSATION AND
ANY PROPRISTORMARTk" EXECUTIVE YIN
OFFICERIVEMSEREXCLUDED7
NIA
=01500000
0110112015^
01101/2016
— WC STATUTORY OTW
x UMrrs ER
E. AC
--
SOW ORB
__
(Mandatary to M
RYee. daw ba www
E.. DISEASE -EA EMPLOYEE
1 aw
DESCRIPTION OF OPERATIONS balm
E L. DISFASE4XMY LWffS
09OORR
DESCRIPTION OF OPERATIONS I LOCATIONS f VEHICLES (Attach ACORD 101, Add/fanal Reworks, Schedule, 8 mono space to roquired)
EFFECTIVE 12I31120D3, COVERAGE IS FOR 100% OF THE EMPLOYEES OF FRANKCRUM LEASED TO ACESO ROOFING CORP. (CLIENT) FOR
WHOM THE CLIENT IS REPORTING HOURS TO FRAWCRUM, COVERAGE IS NOT EXTENDED TO STATUTORY EMPLOYEES. {CLIENT REFERENCE:
LICENSE NUMBER.#CCC058112)
CERTIFICATE HOLDER CANCELLATION
01968-2010 ACORD CORPORATION. All rights reserved.
ACORD 26 120 1 01067 The ACORD name and logo are registered marks of ACORD
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE
EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH TILE
POLICY PROVISIONS.
AUTHOR=ED REP ENTATME
MIAMI SHORES VILLAGE BLDG. DEPT,
10050 NE 2 AVE.
MIAMI SHORES, FL 33138
01968-2010 ACORD CORPORATION. All rights reserved.
ACORD 26 120 1 01067 The ACORD name and logo are registered marks of ACORD
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date: I 1b
10050 NE 2nd Ave
Miami Shores, FI 33138
Re:
Owner's Name: AVERILL DORSETT
Property Address: 117 NW 92 ST MIAMI SHORES, FL 33150
Roofing Permit Number.
Dear Building Official:
I AVERILL DORSETT certify that I am not required to retrofit the roof to wall connections of my
building because:
*The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)
AVERILL DORSETT
Signature
Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this 1 day of 2b
PAOLABASSI
' f MY COMMISSION # EE 179099
Notary Public, Sate of Florida at Lam Q EXPIRES: March 13, 2616
,_a
When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the bu0ding was not constructed with FBC nor a 1994
SFBC. Then you must provide a butiding application from a General Contractor for the Roof to Wall connection Hurricane Mitigation.
Revised on 5/21/2009
Florida Building Code Edition 2010
High Velocity Hurricane Zone Uniform Permit Application Form
Section C (Low Sloped Roof System)
Fill In Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet
and Identify Manufacturer Attachment
(If a component is not used, identify as "NAJ
System Manufacturer: l
NOA No.: % 7 0 /l
Design Wind Pressures, From RAS 128 or Calculations:
Pmaxi : L45 - i Pmax2: 3-4 (P Pmax3:tk to -
Max. Design Pressure, From the Specific NOA
System: S Z -
Deck: ",�
Type: 1/� 6 o 6
Gauge/Thickness: Is
Slope:
Anchor/Base Sheet & No. of Ply(s): AJI
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer: Ak*fYx—
Base Insulation Size and Thickness:
8/
Base
Base Insulationstenerlgondipg Material:
Top Insulation Layer: A114 -
Top Insulation Size and Thickness: AIIA
Top Insulation Fastener/Bonding Material: .114
Base Sheet(s) & No. of Ply(s):%'`S
Basan ShP.et FasteoerBonding Material: .
O ?--A-0170 /-19.1-
Ply Sheet(s) & No. of Piy(s): R&
Ply Sheet
Field: 't " oc @ Lap,.# Rows @ " oc
Perimeter: (-2 " oc @ Lap, # Rows LL @ " oc
Comer: oc @ Lap, # Rows (2 @ —!L" oc
Number of Fasteners Per Insulation
Board
Field: Perimeter Comer _
Illustrate Components Noted and
Details as Applicable:
Woodblocking, Gutter, Edge Termination,
Stripping, Flashing, Continuous Cleat, Cant
Strip, Base Flashing, Counter- Flashing,
Coping, Etc.
Indicate: Mean Roof Height, Parapet Height,
Height of Base Flashing, Component Material,
Material Thickness, Fastener Type, Fastener
Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
Al)
Parapet
Height
/0/
IWOO
OO Mean
L �`=' Roof
Il#75,9 -
Top Ply: A& -z d p vdir,ed 6,a?A"T
Top Ply Faste�
Surfacing:
SECTION 84402.13
HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
84402.13.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the
owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of
Section R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner and the
co act9prThe owner's initial in the adjacent box indicates that the item has been explained.
. Aesthetics -Workmanship: The workmanship provisions of Section R4402 are for the purpose of
providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics
(appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color
or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement
N
a owner and the contractor.
2. Renalling Wood Decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system.)
144P3. Common Roofs: Common roofs are those which have no visible delineation between
neighboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing
ntra and/or owner should notify the occupants of adjacent units of roofing work to be performed.
4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking
can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing
nail penetrations of the underside of the decking may not be acceptable. This provides the option of maintaining
M
'ance.
. Ponding Water: The current roof system and/or deck of the building may not drain well and
water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of
structural distress and may require the review of a professional structural engineer. Ponding may shorten
the life expectancy and performance of the new roofing system. Ponding conditions may not be evident
until th original roofing system is removed. Ponding conditions should be corrected.
W6.Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
eoaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge
if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of
the roof.
Exception: Attic spaces, designed by a Florida licensed engineer or registered architect to eliminate the attic
enting, venting shall not be required.
tu6e i Aaj __
//
wner's/ gent's Signature Date Contractor'sature
11-19 I/tv 9; 7 -
Property
Property Address Permit Number
MIAMI -DARE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economv
GAF
1361 Alps Road
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION:: GAF Ruberoie Modified Bitumen Roof System for Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 13-0424.14 and consists of pages 1 through 29.
The submitted documentation was reviewed by Jorge L. Acebo.
L I JAPPROVED1J
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 1 of 29
ROOFING SYSTEM APPROVAL
Category
Roofing
Sub -Category:
Modified Bitumen
Material:
APP/SBS
Deck Type:
Wood
Maximum Design
Pressure: -75 psf.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Matrix 102 SBS 5 gallons ASTM D3019 Fiber reinforced rubberized cold -applied
Membrane Adhesive adhesive for modified bitumen roof
systems.
GAFGLAS® #75
39.37'
ASTM D4601
Type II asphalt impregnated and coated
Base Sheet
(1 meter) Wide
glass mat base sheet.
GAFGLAS® #80 Ultima
39.37'
ASTM D4601
Type II asphalt impregnated and coated,
Base Sheet
(1 meter) Wide
fiberglass base sheet.
GAFGLAS® FlexPlym 6
39.37'
ASTM D2178
Type VI asphalt impregnated glass felt
(I meter) Wide
with asphalt coating.
GAFGLAS® Ply 4
39.37'
ASTM D2178
Type IV asphalt impregnated glass felt
(1 meter) Wide
with asphalt coating.
GAFGLAS®Mineral
39.37'
ASTM D3909
Asphalt coated, glass fiber mat cap sheet
Surfaced Cap Sheet
(1 meter) Wide
surfaced with mineral granules.
GAFGLAS® EnergyCap'
39.37'
ASTM D3909
Asphalt coated, glass fiber mat cap sheet
BUR Mineral Surface Cap
(1 meter) Wide
surfaced with mineral granules with
Sheet
factory applied EnergyCote'.m
GAFGLAS® Stratavene
39.37"
ASTM D4897
Fiberglass base sheet coated on both sides
Eliminator. Perforated
(1 meter) Wide
with asphalt. Surfaced on the bottom side
Venting Base Sheet
with mineral granules embedded in
asphaltic coating with factory
perforations.
GAFGLAS® Stratavene
39.37"
ASTM D4897
A nailable, fiberglass base sheet coated on
Eliminator' Perforated
(1 meter) Wide
both sides with asphalt. Surfaced on the
Nailable Venting Base
bottom side with mineral granules
Sheet
embedded in asphaltic coating.
Ruberoid® SBS
39.37"
ASTM D6164
Non -woven polyester mat coated with
Heat -Weld"' Smooth
(1 meter) Wide
polymer -modified asphalt and smooth
surfaced.
Ruberoid® SBS
39.37"
ASTM D6164
Non -woven polyester mat coated with
Heat -Weld"° Granule
(1 meter) Wide
polymer -modified asphalt and surfaced
with mineral granules.
Roofmatch`'
107 sq. ft.
ASTM D6164
Non -woven polyester mat coated with
SBS Modified Granular
(9.9 m2)
SBS polymer -modified asphalt and
surfaced with colored mineral granules.
Ruberoid® SBS
39.37"
ASTM D6164
Non -woven polyester mat coated with fire
Heat -Weld" 170 FR
(1 meter) Wide
retardant polymer -modified asphalt and
surfaced with mineral granules.
NOA No.: 14-0611.01
Expiration Date: 11/06/15
MIAMFDADECOUNTY
J JAPPROVED1
Approval Date: 11/06/14
Page 2 of 29
Test
Product
Product
Dimensions
Specification
Description
Ruberoid® SBS
39.37"
ASTM D6164
Non-woven polyester mat coated with
Heat-Weld' Plus
(1 meter) Wide
polymer-modified asphalt and surfaced
with mineral granules.
Ruberoid® SBS
39.37"
ASTM D6164
Non-woven polyester mat coated with fire
Heat-Weld Plus FR
(1 meter) Wide
retardant polymer-modified asphalt and
surfaced with mineral granules.
Ruberoie EnergyCap-
39.37'
ASTM D6164
Non-woven polyester mat coated with fire
SBS Heat-Weld' Plus FR
(1 meter) Wide
retardant polymer-modified asphalt and
surfaced with mineral granules and with
factory applied EnergyCote.
Ruberoid® SBS
39.37'
ASTM D6163
Non-woven polyester mat coated with
Heat-Weld" 25
(1 meter) Wide
polymer-modified asphalt and smooth
surfaced.
Ruberoid® Mop Granule
39.37'
ASTM D6164
Non-woven polyester mat coated with
(1 meter) Wide
polymer-modified asphalt and surfaced
with mineral granules.
Ruberoid® Mop Smooth
39.37'
ASTM D6164
Non-woven polyester mat coated with
(1 meter) Wide
polymer-modified asphalt and smooth
surfaced.
Ruberoid® Mop Plus
39.37'
ASTM D6164
Non-woven polyester mat coated with
(1 meter) Wide
polymer-modified asphalt and surfaced
with mineral granules.
Ruberoid® Mop 170FR
39.37'
ASTM D6164
Non-woven polyester mat coated with fire
(1 meter) Wide
retardant polymer modified asphalt and
surfaced with mineral granules.
Ruberoid® Mop FR
39.37'
ASTM D6164
Non-woven polyester mat coated with fire
(1 meter) Wide
retardant polymer-modified asphalt and
surfaced with mineral granules.
Ruberoid® Torch Smooth
39.37'
ASTM D6222
Non-woven polyester mat coated with
(1 meter) Wide
APP modified asphalt and smooth
surfaced.
Ruberoid® Torch Granule
39.37'
ASTM D6222
Non-woven polyester mat coated with
(1 meter) Wide
APP modified asphalt and
surfaced with mineral granules
Ruberoie EnergyCap-
39.37'
ASTM D6222
APP modified cap membrane with a torch
Torch Granule FR
(1 meter) Wide
grade bottom surface and a mineral
granular top surface coated with factory
applied EnergyCote�'.
Ruberoie EnergyCap-
39.37'
ASTM D6222
APP modified cap membrane with a torch
Torch Granule Plus FR
(1 meter) Wide
grade bottom surface and a mineral
granular top surface coated with factory
applied EnergyCote'�.
RoofMatch7
107 sq. ft.
ASTM D6222
Non-woven polyester mat coated with
APP Modified Granular
(9.9 m2)
APP polymer-modified asphalt and
surfaced with colored mineral granules.
Ruberoid® Torch FR
1 meter
ASTM D6222
Non-woven polyester mat, coated with fire
(39.37') Wide
retardant asphalt modified bitumen
membrane with granule surface.
NOA No.: 14-0611.01
MIAMI•DADECOUNTY
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 3 of 29
Protection
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 4 of 29
Test
Product
Product
Dimensions
Specification
Description
Ruberoid® 20
1 meter
ASTM D6163
SBS modified asphalt base sheet reinforce
(39.37") Wide
with a glass fiber mat.
Ruberoid® 30
1 meter
ASTM D6163
Non -woven fiberglass mat coated with
(39.37") Wide
polymer modified asphalt and surfaced
with mineral granules.
Ruberoid®30 FR
1 meter
ASTM D6163
Non -woven fiberglass mat coated with fire
(39.37") Wide
retardant, polymer -modified asphalt and
surfaced with mineral granules.
Ruberoie EnergyCap- 30
1 meter
ASTM D6163
Non -woven fiberglass mat coated with fire
FR SBS Membrane
(39.37") Wide
retardant, polymer -modified asphalt and
surfaced with mineral granules and with
factory applied EnergyCote.
Ruberoid® Dual FR
39.37" (1 meter)
ASTM D6162
Non -woven polyester and fiberglass mat
Wide
coated with file retardant, polymer -
modified asphalt and surfaced with
mineral granules.
Topcoat® Elastomeric
1, 5 or 55 gallons
ASTM D6083
An acrylic, water based elastomeric
Roofing Membrane
membrane system designed to protect
various types of roofing surfaces.
Topcoat® MB Plus
5 or 55 gallons
Proprietary
Water based, low VOC primer used to
block asphalt bleed -through.
Topcoat®
5 gallons
ASTM D6083
Solvent based sprayable thermoplastic
Surface Seal SB
rubber sealant designed to protect and
restore aged roof surfaces and to increase
a roofs reflectivity.
FireOut' Fire Barrier
5, 55 gallons
Proprietary
Low VOC, water-based fire barrier
Coating
coating.
VersaShieie
42" x 100' rolls
ASTM D226
Non -Asphaltic, fire resistant fiberglass -
Fire -Resistant Roof Deck
based underlayment.
Protection
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 4 of 29
APPROVED INSULATIONS:
Product Name
EnergyGuarC
Polyiso Insulation
EnergyGuarC
RA Polyiso Insulation
EnergyGuard7
RN Polyiso Insulation
EnergyGuarC
Perlite Recover Board
EnergyGuarC
Perlite Roof Insulation
EnergyGuarC
RA Composite Polyiso
Insulation
Carbon steel fastener used
StructodeV High Density Fiber Board
SecurocO Gypsum -Fiber Roof Board
APPROVED FASTENERS:
Table 2
Product Description
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Perlite recover board
Perlite roof board
Polyisocyanurate/wood fiberboard
or perlite composite
High density wood fiber
Gypsum board
TABLE 3
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
Blue Ridge FiberBoard, Inc.
United States Gypsum Corp.
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
1.
Drill -Tec'"
#12 Fastener
Carbon steel fastener used
Various
GAF
in steel or wood decks.
2.
Drill-TecT'
#14 Fastener
Carbon steel fastener used
Various
GAF
in steel, wood or concrete
decks.
3.
Drill -Tec"'
XHD Fastener
Carbon steel extra heavy
Various
GAF
duty fastener used in steel
decks.
4.
Drill -Tec""
AccuTrac®Flat
AZ -SS aluminized steel
3" x 3"
GAF
Plate
plate for use with Drill-
TecTm#12 Fastener, Drill -
Tec TM#14 Fastener and
Drill-Tec"m #15 Fastener.
5.
Drill-Tec'M
ASAP 3S
Drill-Tec"4 #12 fastener
Various
GAF
with Drill-Tec"m 3"
Standard Steel Plate.
6.
Drill -Tec'
AccuTrac®
Galvalume Steel plate for
3" x 3"
GAF
Recessed Plate
use with Drill -Tec"'
fasteners.
7.
Drill-Tec'm
3" Steel Plate
Round galvalume steel
3"
GAF
stress plate for use with
Drill -Tec'' fasteners.
8.
Drill -Tec'
3" Standard
Round galvalume plated
3"
GAF
Steel Plate
steel stress plate with
reinforced ribs for use with
Drill -Tec"' fasteners.
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 5 of 29
EVIDENCE SuBmrrTED:
Test Aaency
Test Identifier
Description
Date
Factory Mutual Research Corp.
3029832
FMRC 4470
05/11/07
3010215
FMRC 4470
03/01/01
3001276
FMRC 4470
01/28/99
1 B9A8.AM
FMRC 4470
09/04/97
3D4Q2.AM
FMRC 4470
04/30/97
OD1A8.AM
FMRC 4470
04/01/98
Underwriters Laboratories
R1306
UL 790
07/22/13
Trinity Engineering
4483.04 97-1
TAS 114
06/06/97
PRI Asphalt Technologies, Inc.
GAF -020-02-01
ASTM D249
02/01/02
ASTM D4977
GAF 306-02-01
ASTM E96
07/07/11
GAF 315-02-01
ASTM D2178
8/23/11
GAF 314-02-01
ASTM D2178
8/23/11
IRT-ARCON Inc.
02-005
TAS 114
03/01/02
02-014
TAS 114
04/08/02
01-039
TAS 114
03/01/02
Trinity ERD
G6850.08.08
ASTM D6164
08/29/08
G6850.08.08
ASTM D6163
08/01/08
G6850.10.08
ASTM D6222
10/06/08
G6850.11.08
ASTM D6222
11/05/08
G40620.07.12-2
ASTM D6222
07/17/12
G34140.04.11-2
ASTM D6163
04/25/11
G31360.03.10
ASTM D6164
03/31/10
G34140.04.11-4
ASTM D4601
04/25/11
G34140.04.11-5
ASTM D4897
04/25/11
G33470.01.11
ASTM D6164
01/13/11
G6850.08.07-1
ASTM D3909
08/13/07
G30250.02.10 -3-R1
ASTM D3909
11/26/12
PRI Construction Technologies LLC.
ASTM D2178
GAF -314-02-01
08/23/11
ASTM D2178
GAF -315-02-01
08/23/11
ASTM D6083
GAF -245-02-01
06/10/10
ASTM D6083
GAF -084-02-01
07/08/05
ASTM D6083
GAF -245-02-01
06/10/10
ASTM D6083
GAF -084-02-01
07/08/05
Momentum Technologies, Inc.
ASTM D6162
AX04C9A
06/05/09
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 6 of 29
APPROVED ASSEMBLIES
Membrane Type:
SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
19/32" or greater plywood or wood plank
System Type A(1):
Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
Fire Barrier:
FireOut"' Fire Barrier Coating, VersaShielde Fire-Rdsistant Roof Deck Protection
(optional)
or Securocke Gypsum -Fiber Roof Board.
Anchor sheet:
GAFGLAS® #80 Ultima Base Sheet, GAFGLAS® Stratavente Eliminator'°'
Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid` SBS Heat -Weld' Smooth
or Ruberoid® SBS Heat -Weld" 25 base sheet mechanically fastened to deck as
described below.
Fastening
GAFGLAS® Ply 4, GAFGLAS® F1exPly"' 6, GAFGLAS® #75 Base Sheet or any
Options:
of above anchor sheets attached to deck with approved annular ring shank nails
and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows
12" o.c. in the field.
(Maximum Design Pressure -45 psf. See General Limitation #7)
GAFGLAS® Ply 4, GAFGLAS® F1exPly' 6, GAFGLAS® #75 Base Sheet or any
of above anchor sheets attached to deck with Drill -Tec"' #12 Fastener, Drill-Tec'm
#14 Fastener or Drill -Tec"° XHD Fastener and Drill -Teem 3" Steel Plate, Drill -
Tec"' AccuTrace Flat Plate or Drill -Teem AccuTrace Recessed Plate installed 12"
o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #7)
GAFGLAS® FlexPly"' 6, GAFGLAS® #75 Base Sheet or any of above anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —52.5 psf. See General Limitation #7)
GAFGLAS® #80 Ultima"' Base Sheet, Ruberoid020, Ruberoid® Mop Smooth base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
field.
(Maximum Design Pressure —60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with
Drill-Tec"O #12 Fastener, Drill -Tec" #14 Fastener or Drill -Tec"" XHD Fastener
and Drill -Tec"' 3" Steel Plate, Drill -Tec"" AccuTrac® Flat Plate or Drill -Teem
AccuTrace Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —60 psf. See General Limitation #7)
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 7 of 29
Fastening Any of above anchor sheets attached to deck approved annular ring shank nails
Options: and 3" inverted Drill -Tec"' insulation plates at a fastener spacing of 9" o.c. at the
(Continued) 4" lap staggered in two rows 9" in the field.
(Maximum Design Pressure —60 psf. See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with
Drill -Tec"' #12 Fastener, Drill-Tec"m #14 Fastener or Drill-TecT" XHD Fastener
and Drill -Tec"" 3" Steel Plate, Drill-TecAccuTraco Flat Plate or Drill-TecTm
AccuTrac® Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maximum Design Pressure —75 psf. See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
EnergyGuard"" Polyiso Insulation, EnergyGuarC Polyiso RA Insulation,
EnergyGuarC Polyiso RN Insulation, EnergyGuar4r RA Composite Polyiso Insulation
Minimum 1" thick N/A N/A
Structodek® High Density Fiber Board, EnergyGuarC Perlite Recover Board
Minimum %" thick N/A N/A
EnergyGuardT" Perlite Roof Insulation
Minimum %" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 20-40 lbs./100 fe. Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene
Eliminator'' Perforated Venting Base Sheet laid dry or a layer of EnergyGuarr Perlite Roof
Insulation or wood fiber overlay board on all polyisocyanurate applications.
Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80
Ultima Base Sheet, GAFGLAS® Ply 4, GAFGLAS FlexPlyT. 6, GAFGLAS®
Stratavene Eliminator Perforated Venting Base Sheet (laid dry), Ruberoid® Mop
Smooth, Ruberoid® 20, Ruberoid® SBS Heat -Weld' Smooth or Ruberoid® SBS
Heat -Weld"' 25 directly over the top layer of insulation. Adhere with any
approved mopping asphalt applied within the EVT range and at a rate of 20-40
lbs./sq. (See General Limitation #4).
Ply Sheet: (Optional) One or more plies GAFGLAS® Ply 4, GAFGLAS® F1exPly"M 6,
GAFGLAS® #80 Ultima Base Sheet, Ruberoid® Mop Smooth, Ruberoid® 20
adhered in a full mopping of approved asphalt applied within the EVT range and
at a rate of 20-40 lbs./sq.
Membrane: One or more plies of Ruberoid® 20, Ruberoie 30, Ruberoie EnergyCap' 30 FR
SBS Membrane, Ruberoid® 30 FR, Ruberoid® Mop Smooth, Ruberoid® Mop 170
FR, Ruberoid® Mop Granule, RoofMatch7 SBS Modified Granular, Ruberoid®
Mop Plus, Ruberoid® Mop FR or Ruberoid® Dual FR fully adhered in an approved
asphalt at an application rate of 25 lb./sq. f 15%.
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 8 of 29
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 3001bs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. GAFGLAS® Mineral Surfaced Cap Sheet or GAFGLAS® EnergyCapTm BUR Mineral
Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq.
3. Topcoat® Elastomeric Roofing Membrane, Topcoat® MB Plus (to be used as a primer with
Topcoat® Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5
gal./sq.
Maximum Design
Pressure: See Fastening Options
NOA No.: 14-0611.01
Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 9 of 29
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® F1exPly TM 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum '/a" DensDeck® Roof Board or '/2" Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4'x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be
placed every 12' in each ribbon to allow cross'ventilation. Asphalt application of either system shall
be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum
design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of
275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value,
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Oficial, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida-
Building
loridaBuilding Code and Rule 61 G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
s
NOA No.: 14-0611.01
MIAMFDADE COUNTY Expiration Date: 11/06/15
... Approval Date: 11/06/14
Page 29 of 29
Roofing Systems Page 13 of 50
BarMer Board (Optional): —One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime
Roofboard" or "DensDeck@ DuraGuardTM Roofboard% minimum 1/4 -In. thick, or United States Gypsum Co. "SECUROCK@ Roof
Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), minimum 1/4 -in. thick.
r Insulation: — One or more layers perlite or glass fiber or 3/4-1n. minimum polyisocyanurate or urethane or perlite/polyisocyanurate
composite or perlite/urethane composite, IIh-in. minimum.
Base Sheet (Optional): — One or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or -Tri-Ply@
Ultra -Flexible Ply 6" or Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 Ultima'"' Base Sheet" or
"GAFGLAS@ Stratavent@ EllminatorTM Venting Base Sheet (Perforated or Nailable)" or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet"
or "Tri -Ply@ Mineral Surfaced Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt.
Membrane: — One or more plies "Ruberoid@ Torch" membranes (Smooth or Granule), torch applied or "Ruberoid@ Mop" membranes
(Smooth or Granule), fully adhered with hot roofing asphalt.
Coating: — Grundy "AL MB Aluminum Roof Coating", applied at a rate of 1 -gat. to 2-gal./100-ft.2.
9. Deck: C-15/32 Incline: 1/2
Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime
Roofboard" or "DensDeck@ DuraGuard'" Roofboard", minimum 1/4 -in. thick, or United States Gypsum Co. "SECUROCK@ Roof
Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), minimum Ve-in. thick.
Insulation (Optional): — One or more layers perlite or glass fiber or 3/4 -In. minimum or polylsocyan u rate or urethane or
perlite/potyisocyanurate composite or perlite/urethane composite or phenolic, 11h -in. minimum.
Base Sheet: — One or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 Ultima'"'
Base Sheet" or "GAFGLAS@ Stratavent@ Eliminator'" Venting Base Sheet (Perforated or Nailable)", mechanically fastened or fully
adhered with hot roofing asphalt.
Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or 'Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -Flexible Ply
6", fully adhered with hot roofing asphalt.
Membrane: — "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual FR" or "Ruberoid@ EnergyCap'" Dual FR" or "Ruberoid@ Mop FR" or
"Ruberoid@ EnergyCap'" Mop FR", fully adhered with hot roofing asphalt.
Coatlng (Optional): — "GAF Fibered Aluminum Coating", applied at a rate of ilh-gal./100-ft.2 or "GAF Weather Coat Emulsion", applied
at a rate of 3-gal./100-ft.2.
10. Decks C-15/32 Incline: 1/2
Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime
Roofboard" or "DensDeck@ DuraGuard"" Roofboard", minimum 1/4-1n. thick, or United States Gypsum Co. "SECUROCK@ Roof
Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), minimum 1/4-1n. thick.
Insulation (Optional): — Perlite or fiber glass or polyisocyanurate or urethane or perlite/polyisocyanurate composite.
Base Sheet: — One or more layers Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-PlyO #75 Base Sheet" or "GAFGLAS@ #80 Ultima'"'
Base Sheet" or "GAFGLAS@ Stratavent@ Eliminator" Venting Base Sheet (Perforated or Nailable)" or Type G3 "GAFGLAS@ Mineral
Surfaced Cap Sheet" or " Tri -Ply@ Mineral Surfaced Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt.
Ply Sheet (Optional): — One or more piles Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -
Flexible Ply 6", fully adhered with hot roofing asphalt.
Membrane: — "Ruberold@ Mop 170 FR" or "Ruberold@ Dual FR" or "Ruberoid@ EnergyCap Dual FR" or "Ruberoid@ Mop FR" or
"Ruberold@ EnergyCap'" Mop FR", fully adhered with hot roofing asphalt.
11. Deck: C-15/32 Incline: 1/2
Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime
Roofboard" or "DensDeck@ DuraGuardTM Roofboard", minimum 1/4-1n. thick, or United States Gypsum Co. "SECUROCK@ Roof
Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), minimum 1/4 -in. thick.
Insulation (Optional):4— Perlite or fiber glass or polyisocyanurate or urethane or perlite/polyisocyanurate composite, butt joints offset
a minimum of 6-1n. from plywood deck joints.
Base Sheet. — One or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 Ultima -
Base Sheet" or "GAFGLAS@ Stratavent@ Eliminator"° Venting Base Sheet (Perforated or Nallable)" or Type G3 "GAFGLAS@ Mineral
Surfaced Cap Sheet" or "Trl-Ply@ Mineral Surfaced Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt.
Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS@ Ply 4" or "rri-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6"-or'Tri-Ply@ Ultra -
Flexible Pty 6", fully adhered with hot roofing asphalt.
Membrane: — One ply "Ruberold@ Torch Smooth" or "Tri -Ply@ TP -4", torch applied or "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop
Smooth 1.5" or "Ruberold@ Mop Smooth Plus" or "Ruberoid@ Dual Smooth", fully adhered with hot roofing asphalt.
Membrane: — "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual FR" or "Ruberold@ EnergyCap Dual FR" or "Ruberoid@ Mop FR" or
"Ruberoid@ EnergyCap'" Mop FR", fully adhered with hot roofing asphalt.
12. Deck: NC Incline: 1
Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime
Rootboard" or "DensDeck@ DuraGuardTM Roofboard", minimum 1/4-1n. thick, or United States Gypsum Co. "SECUROCK@ Roof
Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), minimum 1/4 -in. thick.
Insulation (Optional): — Perlite or fiber glass or wood fiber or polyisocyanu rate or urethane or perlite/polylsocyanurate composite.
_rte Base Sheet. — One or more layers Type G2 "GAFGLAS@ #75 Base Sheet" or 'Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 Ultima'"
P1rU Base Sheet" or "GAFGLAS@ Stratavent@ Eliminator'" Venting Base Sheet (Perforated or Nallable)" or Type G3 "GAFGLAS@ Mineral
e Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet", mechanically fastened or fully adhered with hot roofing asphalt.
Ply Sheet (Optional): — One or more plies Type G1 "GAFGLAS@ Ply 4" or'Trl-Ply@ Ply 4" or "GAFGLAS@ Flex Ply 6" or "Tri -Ply@ Ultra -
i. Flexible Ply 6", fully adhered with hot roofing asphalt.
Membrane: — "Ruberoid@ Mop 170 FR" or "Ruberold@ Dual FR" or "Ruberold@ EnergyCap Dual FR" or "Ruberold@ Mop FR" or
"Ruberold@ EnergyCap'" Mop FR", mechanically fastened or fully adhered with hot roofing asphalt.
13. Deck: NC Incline: 1/2
Barrier Board (Optional): — One or more layers Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck@ Prime
Roofboard" or "DensDeck@ DuraGuardTM Roofboard", minimum'/4-in. thick, or United States Gypsum Co. "SECUROCK@ Roof
Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX), minimum 1/4 -in. thick.
Insulation (Optional): — Perlite or fiber glass or wood fiber or poiyisocyanurate or urethane or perlite/polyisocyanurate composite.
http://database.ul.comlegi-binIXYVItemplatelLI SEXTI1 FRAMElshowpage.html?name=TGFU.R 1306&ccnsho... 11/4/2014