Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-15-1185
Project Address Miami Shores Village 10050 N.E. 2nd Avenue NE Miami Shores, FL 33138-0000 Phone: (305)795-2204 Parcel Number Aonlicant 278 NE 101 Street 1132060134600 Miami Shores, FL Block: Lot: HERBERT AND RUMIKO WINST( owner information Address Phone Cell HERBERT AND RUMIKO WINSTON 278 NE 101 ST (786)423-1941 MIAMI SHORES FL 33138-2423 Contractor(s) Phone Cell Phone PIONEER ROOFING COMPANY INC (954)920-8677 Type of Work: Repair (Additional Info: ROOF REPAIR OVER LIVING ROOM & BATH Classification: Residential Scannina: 3 Fees Due Amount CCF $2.40 DBPR Fee $2.00 DCA Fee $2.00 Education Surcharge $0.80 Permit Fee - Repairs $119.58 Scanning Fee $9.00 Technolm Fee $3.20 Total:" $138.98 1-9 C9 - co Valuation: $ 3,986.00 i Total Sq Feet: 200 Pav Date Pav Tvoe Amt Paid Amt Due I Invoice # RF -5-15-55618 05/19/2015 Check* 11877 05/26/2015 Check #: 11897 $ 50.00 $ 88.98 $ 88.98 $ 0.00 Available Inspections: Inspection Type: Roof Repair Final Roof Review Roof In considoRtion of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertainingereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting%s permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required O'ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNER4FIDAVIT: I certify that all the foregoing informatioJ� is :uWand that ail work will be done in compliance with all applicable laws regulating construction'and zoning. Futhermore, I authorize the above-nar' tr or to do the work stated. May 26, 2015 horized Signature: Owner / Applicant / ContrafGW / Agent Date Buil g Department Copy May 26, 2015 1 Miami Shores Village CEI Building Department MAY i 2095 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 i INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 ICS BUILDING Master Permit No. S �l �J--' PERMIT APPLICATION Sub Permit No. F-1 BUILDING ❑ ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 2 I U N EON ,./ City: Miami Shores p County: Miami Dade Zip: .3313 Folio/Parcel#: 1 lt"'iQ®� - cps® Is the Building Historically Designated: Yes NO )1,_ Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Ap- � A- 1• AJw>sT0 K) Phone#30?S3 Z� V .e 3& Address:: ?_ 9 9 K)s 10 1 $'Tt•e e'\ �-- ,,/ City: MNA.Ms ..SNIACS State: L Zip: 33138 Tenant/Lessee Name: Email: CONTRACTOR: Company Name: �� i�°� �! �% ' Phone#:� f Address: City: I� � State: L Zip: Qualifier Name: L jLh2'Pq L-1 L t Phone#: �5q - Co 53Y�_ State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: ne#: Address City: State Zip: Value of Work for this Permit: $ 39 � _ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New E Repair/Replace ❑ Demolition Description of Work: (VO ( W -) A6 ( olf-e r 11v q roo., 4 rn04-4coom Specify color of color thru tile: Submittal Fee $ Permit Fee $ ( CCF $ Scanning Fee $ Technology Fee $, Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ DBPR $ CO/CC $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ M Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. 1-11-A% Signature_ �:� OWNER or AGENT The foregoing instrument was acknowledged before me this —� day of 20 �°�, by ✓�?��a�"a who is personally known to me or who has produced F4 k/C'W5t as identification and who did take /an v,5 -Al _ NOTARY PUBLIC: Sign:JA Print: pbu ) ti�9 7 ad" f 1NwAV1','y44w1 wifflum, The foregoing ihstrum6nt was acknowledged before me this day of I 'li ) 20 who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign e' 7�Z— a °� Print: fdldd Seal: LOA SUE BROMM Seal: * My COMMISSION # EE A% t Y Pue * EXPIRES: November 22, 2015 �° , ••• ; �% LINDA SUE BROMLEY a� �,�, get No" 9e MY COMMISSION 4 EE 148 40 dL�'x�x�*�x***�xx�*** **���*��* **xx**�*x*�****�*****� �r �1�*�*a�*�x*��xx��* Zv ,r oF e.OP` lie�d'i1w budget Noisy Servirss APPROVED 6Y Plans Examiner Zoning Structural Review Clerk (Rev1sed02/24/2014) KIUK bUU 1 I, UUVtKNUK STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD mr-ri LMVVJUIV, JCuRCIMR1 LICENSE NUMBER 1 :1 The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 GELFAND, LANNY PIONEER ROOFING COMPANY INC 2026 GRANT ST HOLLYWOOD FL 33020-3546 ISSUED: 08/03/2014 DISPLAYAS REQUIRED BY LAW SEQ# L1408030003118 BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2014 THROUGH SEPTEMBER 30, 2015 DBA: Receipt #: 185 -125 064 ROOF NG/SHEET METAL CONTRACTOR Business Name: PIONEER ROOFING Co INC Business Type: (ROOFING CONTR) Owner Name: LANNY GELFAND Business Opened:ll/17/1982 Business Location: 2026 GRANT ST State/County/Cert/Reg:CCC058041 HOLLYWOOD Exemption Code: Business Phone: 920-8880 Rooms seats Employees Machines Professionals 10 For Vending Business Only Vantlinn Tuna- Tax Amount --------- -- ------------- Transfer Fee NSF Fee Penalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 1 .0.00 27.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations. Mailing Address: LANNY GELFAND 2026 GRANT ST HOLLYWOOD, FL 33020 2014 .2015 Receipt #ICP -13-00012531 Paid 08/18/2014 27.00 i4� V® CERTIFICATE OF LIABILITY INSURANCE DATE 5/19/2015» THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WANED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER Keen Battle Mead & Company 7850 Northwest 146th Street Suite 200 Miami Lakes FL 33016 CON NAMTAE: CT Cynthia Hernandez PHONE(305)558-1101 FAXALC, (305) 822-4722 ADL .chernandez@kbmco.com INSURERS AFFORDING COVERAGE NAIC & INSURER A:Amtrust International INSURED Pioneer Roofing Company, Inc. 2026 Grant Street Hollywood FL 33020 INSURER B: Continental Insurance Company 35289 INSURFRC:Commerce & IndustrV Ins. Co. INSURERD.Valley Forge Insurance Co 20508 INSURER E: INSURER F: COVERAGES CERTIFICATENUMBER:14-15 GL,UMB,WC,AUTO REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE ADDL SUBR POLICY NUMBER POLICY EFF DIYYM POLICY EXP (MM/DDNYYY1 LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RNTED PREMISES(EaEoccurrence) $ 100,000 MED EXP (Any one person) $ 5,000 A CLAIMS -MADE OCCUR PAL104439001 11/13/2014 1/13/2015 PERSONAL &ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $ 2,000,000 $ X POLICYX PRO LOC .IFCTAUTOMOBILE LIABILITYCOMBINED SINGLE LIMIT Ea accident 1,000,000 BODILY INJURY (Per person) $ B X ANY AUTO ALL OWNED SCHEDULED AUTOS AUTOS NON -OWNED HIRED AUTOS AUTOS 5088454402 1/1/2015 1/1/2016 BODILY INJURY (Per accident) $ PROPERTY DAMAGE $ Per accident Medical payments $ 5,000 X UMBRELLA LIAB X OCCUR EACH OCCURRENCE $ 2,000,000 AGGREGATE $ 2,000,000 C EXCESS LIAR CLAIMS -MADE DED I X I RETENTION $ E023343901 11/13/201411/13/2015 D WORKERS COMPENSATION WC STATU-R S1 OTH- AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE Y / N OFFICER/MEMBER EXCLUDED? � (Mandatory In NH) N/A 088785819 1/1/2015 1/1/2016 E.L. EACH ACCIDENT $ 500,000 E.L. DISEASE - EA EMPLOYEE $ 500,000 E.L. DISEASE - POLICY LIMIT $ 500,000 If yes, describe under DESCRIPTION OF OPERATIONS below DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space Is required) Roofing Contractor L" Ralt]LhG117i1J qJR:i City of Miami Shores Building Department 10050 NE 2 Avenue Miami Shores, FL 33138 ACORD 25 (2010/05) INSn2F tgmnrim m SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE Perez/BECKY - �— ©1988-2010 ACORD CORPORATION. All rignts reservea. Tha Ar cion nama and Innn aro raniafararl marirc of A( non ►®.o .. . . . . . . .. . . ... .... ... .... . . ... . .... ....... . .......... 0 00... 0 0 0 000 0 . Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: .5'b� �' - 9 Product Approval Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 131�R • � 132: t 133: LaV. Maximum Design Pressure 0000 0000 Product Approval Specific System: �� " ' .' 0 0 00 a Method of Tile Attachment: 0000 Prrna :900:0 0000 e Roof Slope: --3--:12 Ridge Ventilation? Steep Sloped System Description Type: WOO d- Underlayment: 9 Mean Roof Height: 10 0000.. .• .. .. 0000 0000.. ..0000 .. 0000 0000.. .0000. 0000.. 0000. 0000. 0000.. .sees. 00006. . Type & Spacing: hesive Type: 6� Type Cap Sheet: Covering: ,1::1 Type & Size Drips Edge: �i Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mrwiththe values from Mf. If the Mr values are greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P, 'I x A,'2%_= 9 - Mg -= Mr, 6,)" Product Approval MZ�� (P2: x x a = -Mg - M,2 i-5;1 Product Approval M; (P3: 10' x M9. = Mr3 Product Approval Mf�4 .... Method 2 "Simplified Tile Calculation Per Table Below" " ' V: Required Moment of Resistance (Mr) From Table Below Product ApKF.VP1 Mf Mf Re uired Moment Resistance* Mean Roof Height --► Roof Slope 15' 20' 25' 06:60: 30' • • ; • • • • 40' • " 2:12 34.4 36.5 38.2 39.7 ••�• 42. • 3:12 32.2 34.4 36.0 37.4 • • 39.8+ 4:12 30.4 32.2 33.8 35.1 ' • ' 37.3' 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 1 27.1 28.2 30.0 *Must be used In conjunction with a list of moment based tile systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the the attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P,: x 1: = x w:= _) - W: x cos 0: - = F„ Product Approval F (P2: x 1: = x w:= ) - W: x cos 0: - = F,2 Product Approval F' (P3: x 1: = x w:= ) - W: x cos 0: - = Fi3 Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity Ma Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions I = length w = width Product Approval All calculations must be submitted to the Building Official at the time of permit application. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetics -Workmanship: The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renalling Wood Decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is Au k; Fricealgdppor to removing the existing roof system.) • • • 6666.. .. 3. Common Roofs: Common roofs are those which have no visible •c6WOj�ation between neighboring units (i.e. townhouses, condominiums, etc.) In buildings with commit rmis, thdMfliig contractor and/or owner should notify the occupants of adjacent units of roofing wor6AQJD ,performed6 606006 0 0:00 vlq)�4. Exposed Ceilings: Exposed, open beam ceilings are where the undersideoal4ke roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, thereforegrggIgg nail penetrations of the underside of the decking may not be acceptable. This provides thl op�@Q of maintaining this appearance. • • • • V: 00 6 5. Ponding Water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. )��z 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. )� 7. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Exception: Attic spaces, designed by a Florida licensed engineer or registered ar `ct to eliminate the attic venting, venting shall not be required. / _ /, �s r 6666.. 666666 .6000. 66666 66606 666666 6 6 6 666666 6 666666 Owner's/Agent's Signatur Date Property Address Permit Number MIAMI-DADE COUNTY MIAM�JaDiADE " PRODUCT CONTROL SECTION ' 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA www.miamidade.eov/economy Sulacer USA, Inc. 6801 NW 77 Avenue, Suite #302 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Altusa `°S" Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, an6 following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein • • • *one 0000:0 .. 0000 RENEWAL of this NOA shall be considered after a renewal application has been filed an$'tliere has been no change • • • 0000.. in the applicable building code negatively affecting the performance of this product. • .... • 0000 9 .0009. 0000 . 00000 TERMINATION of this NOA will occur after the expiration date or if there has been a revision orechange in the % 9 materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement o-,;Py;roduCt,- • •; • for sales, advertising or any other purposes shall automatically terminate this NOA. Failure =e CQloly with dty section of this NOA shall be cause for termination and removal of NOA. 00 00 " 0000.. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flon?da, and fv41gwej by the • expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA No. 12-1203.07 consists of pages 1 through 7. The submitted documentation was reviewed by Juan E. Collao, R.A. MIAMFaADE COUNTY NOA No.: 14-0605.03 APPROVED Expiration Date: 08/26/19 Approval Date: 08/28/14 0 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Clay Deck Type: Wood 1. SCOPE This approves a roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.V. and distributed by Sulacer USA, Inc., as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Applicant Dimensions Altusa "S" Clay Roof Tile Length: 18.75" Width: 10.75" Thickness: 0.46" Height: 3.6" Trim Pieces Length: varies Width: varies varying thickness Test Product Specifications Description ASTM C 1167 High profile, one-piece, `S' shaped single roll clay file with a nominal 2-%2 inch headlap. For direct deck nail -on, mortar set, or adhesive set applications. TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Pimienta Cortes, Honduras 2.2. EVIDENCE SUBMITTED Test Agency Test Identifier American Test Lab of South RT0426.01-11 Florida American Test Lab of South RT0706.01-11 Florida American Test Lab of South 2397-116 Florida .... American Test Lab of South RT0712.02-13 Florida American Test Lab of South RT0714.02-14 Florida American Test Lab of South RT0808.01-14 Florida •• a NOA No.: 14-0605.03 Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 2 of 7 . . .... ...... •08.00 •• a ...... 8 ease* •0008. . ..... Test Name/Report • • • • e • • Date—on� • ASTMC 1167 W87/11 . . . . ...... . Static Uplift Testin • a 07/11/11 • TAS 101 •' 0so ASTM C 1167 06/28/07 ASTM C 1167 07/19/13 ASTM C 1167 07/29/14 Aerodynamic Multiplier 08/13/14 Restoring Moment Calculations NOA No.: 14-0605.03 Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 2 of 7 The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 25-7200-1 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (Quick -Drive Screws, Battens) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC -78 TAS 100 Celotex Corporation Testing MTS 520649 TAS 102(A) May 2000 PRI Asphalt Technology, Inc. CLF -003-02-01 TAS 102 October 2001 Redland Technologies 7161-03; Appendix III TAS 102 Dec. 1991 Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 Feb[M 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496.. •!DtI 1996 ' 0":0 Walker Engineering, Inc. Evaluation Calculations .. 25-7584 • • • s • • ... Deeember 1991 • • • • 25-7804b-8 0:0000: 25-7804-4 & 5 .0000. :0 0 6:6 25-7848-6 �•�� � �•�•� . . 0000.. 6 6 . .. 0000. . 606, 6606 6000.0 6..6.6 6 • • . . . 66666. .6...6 6 6 • 0. 6..66600 a NOA No.: 14-0605.03 APPROVED Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set file applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications maybe installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 3.8 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Altusa `S' Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (1 x w) Tile Profile Weight W (Ibf) Length -I (ft) Width -w (ft) Altusa "S" Clay Roof Tile 6.5 1.56 • • 40.90 • • • Table 2: Aerod namic Multipliers - ft' •��� • Tile X (ft) .... x( 3 • Profile Batten Application DCrectfleck AR • 1ication Altusa "S" ClayRoof Tile 0.269 '•;": 0.21 ' Direct Deck Batten .". • •••••• Table 3: Restoring Moments due to Gravity - M9 (ft -lb fj :0606' 20• 12" 311• 12" 4"• 12" 5"• 12" 6"• 12" ••.11 " or reater Batten Direct Deck Batten Direct Deck Batten Direct I Deck Batten Direct Deck Batten Direct Deck Batten Direct Deck 4.70 4.71 1 4.63 4.65 1 4.54 1 4.57 1 4.43 4.46 4.30 4.34 4.16 4.21 LAPPROYED �_� ••• •• • NOA No.: 14-0605.03 Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Me hanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile Resistaiwe° •• (Min 16/32" plywood) (Min. 19/32" plywood) 4 Large paddy placement of 63 grams of 3M- 2 -Component Foam Roof Tile Adhesive AH -160 Altusa "S" 2-10d Ring Shank Nails 28.6 41.2 19.4 Clay Roof Tile • • • • • • •+ 3M'- 2 -Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. 1-10d Smooth or Screw 5.1 6.8 2.8 Shank Nail 2-10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1 48 Screw 28.7 28.7 18.1 2 .#8 Screws 58.2 58.2 26.8 1-10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1-10d Smooth or Screw 29.3 29.3 24.0 Shank Nail Eave Clip) 2-10d Smooth or Screw 27.6 27.6 38.6 Shank Nails Field Clip) 2-10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mt (ft-lbf) for Two Pa#y Adhesive Set Systems Tile Application Tile Tile Application Minimum Attswjynent Profile 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 Resistaiwe° •• Altusa "S° Clay Roof Adhesive 4 Large paddy placement of 63 grams of 3M- 2 -Component Foam Roof Tile Adhesive AH -160 Tile 5 Medium paddy placement of 24 grams of 3W 2 -Component Foam Roof Tile Adhesive AH -160 6 Large paddy placement of 70 grams of 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 See manufacturer's component approval for installation requirements. L32 Flexible Products Company TileBond Average weight per patty 10.7 grams. • • • • • • •+ 3M'- 2 -Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. •• •. .••• Table 6: Attachment Resistance Expressed as a Moment- Mfl -§;q for Single Patty Adhesive Set Systems :°"" Tile Profile Tile Application Mil>tifnilmAtOGOO ent Resistance ' Altusa "S° Clay Roof Tile 3M 2 -Component Foam Roof Tile Adhesive AH -160 66.5 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 38.75 rMw 2 -Component Foam Roof Tile Adhesive AH -160 52.056 4 Large paddy placement of 63 grams of 3M- 2 -Component Foam Roof Tile Adhesive AH -160 5 Medium paddy placement of 24 grams of 3W 2 -Component Foam Roof Tile Adhesive AH -160 6 Large paddy placement of 70 grams of 3M'" 2 -Component Foam Roof Tile Adhesive AH -160 NOA No.: 14-0605.03 �APPR; ED L__ Y Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment - Mt (ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Altusa "S" Clay Roof Tile Mortar Set 24.50 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". ALTUSA MADE IN HONDURAS LABEL FOR ALTUSA "S" CLAY ROOF TILE. (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-0605.03 MIAMI APPRO COUNTY Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 6 of 7 . . .... ...... ...... .. . ...... •••• • ••••• •••••• • •• ••••• • • • • • •••••• NOA No.: 14-0605.03 MIAMI APPRO COUNTY Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 6 of 7 PROFILE DRAWING 1C 0000.. ALTUSA `S' CLAY ROOF TILE • END OF THIS ACCEPTANCE 0000 APPROVED 0000 0000 0000.. 0000 .000.0 . ... . . 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. 0000.. NOA No.: 14-0605.03 Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 7 of 7 e M1lAM1 `: MIAMI -DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.¢ov/eeonomy 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3M Foam Roof Tile Adhesive RTA -1 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. 0000 '' 0000 0000.. TERMINATION of this NOA will occur after the expiration date or if there has been a rejsj9f1 c? changg ivibe materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorswout of a$y ftoduct, fe a .. % sales, advertising or any other purposes shall automatically terminate this NOA. Failure to coy with any section of• • 0000.. this NOA shall be cause for termination and removal of NOA. • • • • • 0000.. 0000 . 0000. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade Counu: Florida, W followdd"• by the expiration date may be displayed in advertising literature. If any portion of the*WA is displayed, then 00 0 • ...... it shall be done in its entirety. • 0000.. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer ot'id distribxtors and : • • • shall be available for inspection at the job site at the request of the Building Official. 0.00 • This revises NOA# 13-0129.01 and consists of pages I through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.02 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 1 of 7 , L 0 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3M Foam Roof Tile Adhesive RTA -1 as manufactured by 3M Company as described below in this Notice of Acceptance. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127. For use with approved flat, low, and high profile roof tile systems using 3M Foam Roof Tile Adhesive RTA -1. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications 3M Foam Roof Tile N/A TAS 101 Adhesive RTA -1 PRODUCTS MANUFACTURED BY OTHERS: Product Description Single component polyurethane foam roof tile adhesive. Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 3M Foam Roof Tile Adhesive RTA -1 roof tile adhesive. MANUFACTURING LOCATION: 1. Norton, OH. PHYSICAL PROPERTIES: Property Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2842 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.95 lbs./fI.3 7.8 psi •••• 15 PSI Parallel to rise • *006 • 4.6 Lbs./Fe 1.94 Perm / Inch +0.89% Volume Change @ 70. V 72 Weeks • • 54.1% • 0•••••• Note: The physical properties listed above are presented as typical average values as deft bh8d by'.;..' accepted ASTM test methods and are subject to normal manufacturing variation....... 0000.. 0000.. 0000.. 0000. 00.00 0000.. 0000.. 0000.. .. 0000 NOA No.: 14-0805.02 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 2 of 7 I L - EVIDENCE SUBMITTED: Test Aeencv Test Identifier Test Name/Repo rt Date Southwest Research Institute 01-1208-025 ASTM E 108 06/16/98 PRI Construction Materials FOP -009-02-10 Physical Properties 12/14/10 Technologies, Inc. FOP -009-02-01 TAS -101 11/8/10 ...... FOP -009-02-02 TAS -101 11/4/10 FOP -009-02-03 TAS -101 11/8/10 FOP -009-02-04 TAS -101 11/8/10 FOP -009-02-05 TAS -101 11/8/10 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. 3M Foam Roof Tile Adhesive RTA -1 can be used with flat, low, medium and high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3M Foam Roof Tile Adhesive RTA -1 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F _W 2 F'= MS 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-0805.02 MIAM�c7o►RO couNT1r VEDI Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 3 of 7 . . .... ...... ...... .. . ...... .... . ..... ...... . .. ..... .. .. .... ...... . . . . ...... NOA No.: 14-0805.02 MIAM�c7o►RO couNT1r VEDI Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 3 of 7 { INSTALLATION: 1. 3M Foam Roof Tile Adhesive RTA -1 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3M Foam Roof Tile Adhesive RTA -1. 2. 3M Foam Roof Tile Adhesive RTA -1 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3M Foam Roof Tile Adhesive RTA -1 shall provide sufficient attachment resistance to meet or exceed the resistance values determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3M Foam Roof Tile Adhesive RTA -1 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Fomo Products, Inc. 3M Foam Roof Tile Adhesive RTA - 1 Operating Instruction and Maintenance Booklet 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after 3M Foam Roof Tile Adhesive RTA -1 has been dispensed. 6. 3M Foam Roof Tile Adhesive RTA -1 placement shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Typical Placement Detail Weight per paddy (grams) Flat, Low & High Profile # 1 12 High Profile 2 -Piece Barrel # 2 12 LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. H MMADECOUNTY •••••• _,•.•� �- • • •0•• 0900•0 •• • • ••• • ••0.9• BUILDING •• • •0.9•• PERMIT REQUIREMENTS: • • • • • • As required by the Building Official or applicable building code in order to properly evaluateA1s711stallatibnAftis system. 0.0• 0.00• ...... . .. ..... . . . . ...... . . ••0••• 69 0 NOA No.: 14-0805.02 MIAMI•DADE COUNTY JAPPROVED1 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 4 of 7 4 j• • APPROVED ADHESIVE PLACEMENT DETAILS PLACEMENT DETAIL # 1 lack ida urse lire le paddy ibm file 0000 0000 0000.. .. . ......- . FLAT PROFILE 0000 0000.. 0000.• 00 • • 0000.. • • 0000•• • • ••• .. • 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0.00.0 ....•• • • NOA No.: 14-0805.02 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 5 of 7 Is LA V PLACEMENT DETAIL # 1 (CONT... fir, • � •r -•- •:•• 006.6. LOW PROFILE 000000 0000.• 0000.. • • Y •0000. 00.00 0000.. • 0000.. ••0000 NOA No.: 14-0805.02 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 6 of 7 NOA No.: 14-0805.02 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 7 of 7 PLACEMENT DETAIL # 2 Paddy on lap of die coil Cted t0 ft tvw paddes t,A1d@rr -a'm file. Part of d� � ♦y Eave OTE' line � 1 p p uu i e aMo�amehY 1" above Ile oww Brie. Eave domm HIGH PROFILE ••.�•• •• • .••••• • •.•••• • • NOA No.: 14-0805.02 Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 7 of 7 -%, A PLACEMENT DETAIL # 2 (CONT... 11 Two T' oblong l� ^ =obi ao�e ine e� 11 skis uidw pante. ^ • ^ onee side wider 1 1 1 awoft 1 1 11 3 Two -1U' oblong sklebiskis underpan tles (eaueaouseoNY)• (1 mWemedomm 0000 • . 0000 0000•• 2 -PIECE BARREL PROFILE 0000•• •• • 0000•• • 0000•. • . • 0000•• 0000 • • • • • • 0000•• END OF THIS ACCEPTANCE 0000 0000 0000.. 0000.. . . . • 0000.• 0000•• ..• • . •••••• 0000 •• • hOAMaDADE NOA No.: 14-0805.02 COUNTY ,..., Expiration Date: 01/03/16 Approval Date: 09/04/14 Page 8 of 7