Loading...
RF-14-2784Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-234213 Permit Number: RF -12-14-2784 Scheduled Inspection Date: May 08, 2015 Inspector: Rodriguez, Jorge Owner: , TROPICAL CHEVROLET Job Address: 8880 BISCAYNE Boulevard 70 Miami Shores, FL 33138 - Project: <NONE> Contractor: THERMA SEAL ROOFS SYSTEMS LLC comments COMPLETELY TEAR OFF EXISTING ROOF AND INSTALL NEW SINGLE PLY MEMBRANE PARTS DEPARTMENT Passed Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Permit Type: Roof Inspection Type: Final Roof Work Classification: Flat Phone Number (305)754-7551 Parcel Number 1132060200770 INSPECTOR COMMENTS False Inspector Comments Phone: (561)223-2096 CREATED AS REINSPECTION FOR INSP-234183. CREATED AS REINSPECTION FOR INSP-233403. CREATED AS REINSPECTION FOR INSP-231957. CREATED AS REINSPECTION FOR INSP-231720. CREATED AS REINSPECTION FOR INSP-225633. Need pictures of 2 X 6 on primeter No ladder/permit 4/24/2015 05/07/2015 CANCELLED BY LORI May 07, 2015 For Inspections please call: (305)762-4949 Page 26 of 33 BUILDING Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FB-�C^ 210 ) Master Permit No. r 1 �' 201 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION (RENEWAL ❑PLUMBING ❑ MECHANICAL []PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 8880 Biscayne Boulevard (8910 NE 5 Ct) Ci Miami Shores County Miami Dade Zip Folio/Parcel#: M70 Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Tropical Chevrolet Phone#: Address: 8880 Biscayne Blvd City: Miami Shores State: Florida Zip: 33138 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Therma Seal Roof Systems, LLC Phone#: 561-223-2096 Address: 804 Old Dixie Highway Ste 6 City: Lake Park state: Florida Zip: 33403 Qualifier Name: Dave Wikel Phone#: State Certification or Registration #: CCC1325862 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 76000 Square/Linear Footage of Work: 5000 Type of Work: ❑ Addition ❑ Alteration ❑ New 0 Repair/Replace ❑ Dem lition . Completely tear off existing roof and install new single ply membrane 1 ('if -t Description of Work. Specify color of color thru tiler Submittal Fee $ Permit Fee $ 03 CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ 4 I 1 (Revised02/24/2014) 6- ' Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such pasted ice, the inspection will not be approved and a reinspection fee will be charged. s op Signature 0:k_Signature �I OWNER or AGENT CONTRACTOR The foregoing instrument was acknowledged before roe this The orreegoing instrument was acknowledged before me this day of 20 , by l day of �� 20 ®� , by , who ipersonally know to who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: YANILIS ALEMAN My Comm. Expires Apr 13, 2015 as me or who has produced identification and who did take an oath. NQ ARY PUBLIC: `,`PpY°P s`TONI SAPIENZA Comrr�l„i1�n # f F 042529 Expires Auacisi 4, 2017 a.= oBonded Tnru Troy d v, insurance 890-398-7919 Sign: R° ` Print:.. Seal: as Zv APPROVED BY � I Plans Examiner Zoning (RevisedO2/24/2014) Structural Review Clerk )c+I> ROVF'AS61�MBLIES AND ROOFTOP STRUCTURES P96 2 r � Florida Building Code Edition JW 201 OCITY High -Velocity Hurricane Zone Uniform Permit Application Form. Co.. Py,Sprtien A (General Information) Master Permit No. Process No. Contractor's Name Therma Seal Roof Systems, LLC Job Address 8880 Biscayne Blvd Miami Shores, Florida 33138 ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE se• • es•• • • • sees•• ❑ New Roof ?4Reroofing ❑ Recovering ❑ Repair ❑ O flairitenanle . • • • .•..•• . .. •.••.• ROOF SYSTEM • • • : • • • . • INFORMATION �••• �••• �••••� .••• sees •ss•s Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) a Tp$g1•(SF) .... • • • • • 00 •• .... 000000 • Spctien R (Roof Plan) � • Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflowtHM. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zoWa4d locatigq 8$ V • • • parapets. • FLORIDA BUILDING CODE — BUILDING r 0000 • • • 0000•• 0000.• • • • • 0000.• 0000.• • • e 000000 010• 0000.• 0000.•e..• ••••• 0000 ..•• 0000• • • • . 0 0 0 00 • • •0000• 000000 0•• • • • 600:00 • •• 0000.0 0. • .• • . . • • • 0 0 • 000.0• 0000•• r _... __._ •_ ..._ _-0000 _. _.._ _0.0__00.. _......_.._ _. _........_.._.....__.. _....l.0l.R.R..._...._. - . � _ s...._.._..._..r0a••-000__0._.,.. • j. •.• 0000.• -------- -- -�----..___._._......•._...._.. 0000 _0000... .._..._._..............__ ••0 •• 0000. 0000 •• 0000• •• 0000•• 0000•• • ..._�..____ ___0_00.0.• 0000... _.. .�...... sYr. r•._-_ __0000 0000 • • 000.0• •• • S.}..• R.._..._..... -.._ • •• 0000 .................. ., ._. 0000.__ ... .�_ _................ ......._....... - __ �r i! j4 i; t� i� r t I f`. 4i! } 0.000. 0000.. 0000.. 0000.. . . 0000 0000 0000. 0000 0000 0000. 0000 0000.. 0000.. 0000.. . . 000• . .. ROOF ASSEMBLIES AND ROOFTOP STRUCTURES if 0 Florida Building Code Edition 2007 High -Velocity Hurricane Zone Uniform Permit Application Form. Section C Low Slope Application) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: "t Product Approval No.:/ 3 09, V Design Wind Pressures, From RAS 128 or Calculations: Pmaxl : ' °� 4 LL Pmax2: Pmax3: j Max. Design Pressure, from the specific Product Approval system:_ Deck: Type: Gauge/Thickness: �r Slope: Anchor/Base Sheet & No. of Ply(s): ®'® Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: D � Base Insulation Size and Thickness: Base Insulation Faste r/ odeg Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastenep'Rp ng Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material• Ply Sheet Fastener/Bonding Material: Top Ply: 9410 077V Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Field: " oc @ Lap, #JR ^ LO" oc Perimeter: " oc @Lap _ @ W'oc; Corner: ," oc, @ @ oc Number of Fasteners Per Insulation Board: Field4— - 11 — Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocldng, Gutter, Edge Termination, 811 , m g, Flashing, Continuous Cleat, Cant Strip,13aspe lashing, ounter- • • ... Flashing, Coping, Etc. • • • • Indicate: Mean Roof Height, P@tltptHeight, Heigh of Base•: Flashing, Component Material *Msterial Thickness, Fastener Type, Fastener Spacing or Submit • sees V006: • 6009 0000 90:09 ....9. 99.9 ...e. 99 9e 9069 900004 9 96.0.9 6 6 6 999960 ..0000 . . .. . .. 0000.. .. . 0000.. 0000.. .0066. . . 0000 0000 00000 666. 0000 0000. 0000 0000.. 0000.. 0000 .. .. 0 •..... 0 . . .....• 0000.. 0000.. . . • • 0000 • s• Forensic Engineering C_ , Inc. MEMBRANE ATTACHMENT CALCULATIONS Project Name Tropical Chevrolet - Roof Areas "N'& "B" Report No.: CIS -MB -14.018 Project Address 8880 Biscayne Boulevard Miami Shores, FL Deck Substrate Steel Insulated Max. Roof Height 26.0 Feet Configuration Low Slope Roof Area (Total) 14425 Sq. Ft. Category II Roof Width 85.0 Feet Exposure Condition C Perimeter Width 8.5 Feet Building Type Enclosed Parapet Height 0.0 Feet Base Wind Speed 175 mph Slope V 0.0 Slope H 12.0 Slope Angle° 0.00 Uplift Pressures qZ = 0.00256 KZ K,t Kd V2 P = qZ (GCp - GCpi) qZ KZ Kzt Kd V GCp GCpo 63.832 0.953 1.005 0.85 175 -1.00 0.18 Field -1.80 0.18 Perimeter -2.80 0.18 Comer e . Field Pi A -75.32 psf PI wd -45.19 psf • • • • • • Perimeter P2 wt -126.39 psf P2 asd -75.83 psf a Comer P3 WL -190.22 psf P3 wd -114.13 psf ...:.. • ••.• well Proposed System Johns Manville TPO Single Ply Roof System • ewes.: see• •ewe Product Approval No. 13-0828.04 (Page 21 of 25) Fastening # 1 .. e. eeeee • �.. e' System Design Pressure -52.5 psf .• .. w... "lee ...... Membrane Full Width 96 inches Side Lap 6 inches Net Wiath e * o igches X90 Membrane Red. Width 66 inches Side Lap 6 inches Net Width . VG lildhes • Membrane Red. Width 46 inches Side Lap 6 inches Net Width 40iiraches : Fasteners Approved High Load Fasteners and Plates Fastener Spacing in Lap of Membrane 6 inches # Rows 1 Min. Characteristic Resistance Force -196.88 Ibf -434.1 Ibf (Low MCRF - TAS -105 Tests) Fastener Spacing {(MCRF/Pt) x 144)/Row Spacing Full Width Membrane Reduced Width Addl. Reduced Width Field Fastener Spacing 6.97 10.46 15.68 Perimeter Fastener Spacing 4.15 6.23 9.35 Comer Fastener Spacing 2.76 4.14 6.21 RECOMMENDED MEMBRANE ATTACHMENT PATTERN Field Rows @ 90" o.c. Full Width Sheet 6 inches on center Perimeter Rows @ 60" o.c. Reduced Width Sheet 6 inches on center Corner Rows @ 40" o.c. Reduced Width Sheet 6 inches on center These calculations have been done in accordance with ASCE 7-10, based on the information provided by the contractor. The roof system must be installed in accordance with the FSC & manufacturer's recommendations. Sincerely Forensic Engineering Consu1tents, Inc. u ri, s l=� R. N. Sailappan, P.E. Principal Engineer Florida Registration No. 46696 Forensic Engineering Consultants, Inc. (CA # 8265), P.O. Box Q70034, Boca Raton, FL -33497 Ph (561) 9018490 Fax (561) 218 3830 • s • • 0000•• 00.00• • • • •• •• •..• 0.00.0 0000•• 0000 s.••. 0000 •..• 0000• 0000 ••.• • • 0000.• • • • • 000.0• • •• 0000.• • • • • • • • 000000 000.0• TESTING APPLICATION STANDARD (TAS) No. 105-11 APPENDIX TAS 105-A FIELD WITHDRAWAL RESISTANCE TEST RESULTS GENERAL INFORMATION: Job Name: Job Address: Job Site Contact: Tropical Chevrolet 8880 Biscayne Blvd. Miami Shores, FL Therma Seal Roof Systems, LLC 561-223-2096 TESTING AGENCY/EQUIPMENT INFORMATION: Note: The undersigned acknowledges that all testing has been conducted and results have been reported in compliance with TAS 105 Appendix T105 -A Testing Agency: Cleary Inspection Services, Inc. Address: 1017 North "H" Street • Lake Worth, FL 33460 •.. • ; 0000.. 0000.. • Telephone: (561) 722 - 9881 • �; .. 0000.. Fax: (561) 582 - 8039 0000 0000 ;0.000 Email: clearyinspections@kcwand.com 0000 0000 0000. Representative Name: Katherine I. Cleary **:so: 00 0 0 0000 0000. see* 0000.. Title: Inspector :••:•: •• •� Test Apparatus: COMTEN MODEL # DFG2W2000, SERIAL # 20606019:.. •' • 0000.. 0000.. :see*: 0000 BUILDING/ROOF SYSTEM INFORMATION: Roof "A" Approx. Roof Area Height: Height: = 26 ft. Roof Area Dimensions: Length: = 133 ft. Second largest dim.: = 31 ft. Total roof area: = 3475 ft.2 Perimeter width: = 3.5 ft. Perimeter area: = 964.8 ft.2 Comer area: = 178 ft.2 Parapet Height: = N/A ft. BUILDING/ROOF SYSTEM INFORMATION: Roof "B" Approx. Roof Area Height: Height: = 21 ft. Roof Area Dimensions: Length: = 180 ft. Second largest dim.: = 70 ft. Total roof area: = 10950 ft.2 Perimeter width: = 8.5 ft. Perimeter area: = 3268.3 ft.2 Comer area: = 722.5 ft.2 Parapet Height: = 1 ft. 1 r . . . . ...... .. .. .... ••eee. ...... .... •e:.e• .... .... ..... .... .... ....: 66.96. • •• . e. 6 • • • • 699906 00000 r 0 ,`, Tropical Chevrolet 8880 Biscayne Blvd. Miami Shores, FL Cleary Inspection Services, Inc. Tel. (561) 722-9881, Fax (561) 582-8039 Email: clearyinspections@kcwand.com FASTENER INSTALLATION INFORMATION: Roofs "A" and "B" Is the fastener a self driller? Yes Tool: Rigid 18v. Drill 0-1800 rpm's Fastener type: #15 Fastener Manufacturer: OMG TEST INFORMATION: Roof "A" 439.5lbf Test Date: 11/24/2014 Number of Test Conducted 10 *Note the Location of all tests on 'Building Information', attached. � • FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET • • • Deck: 0 0 . St0e1 See TAS 105-11 to determine number of tests . 0000 • a • • • • • SSSS Soso ROOF "A" SAMPLE NO. PLAN IDENTIFIER INITIAL FAILURE LOAD FIELD •• •• • • • • • • PERIME• R • • SSSS • Cbl 1 T1 425 439.5lbf '..'.. 2 T2 450 X SSSS 3 T3 525 X 4 T4 375 X 5 T5 515 X 6 T6 495 X 7 T7 475 X 8 T8 450 X 9 T9 500 X 10 T10 500 X STATISTICAL ANALYSIS: ROOF "A" No. of Tests 't' Estimator Mean Failure Load: Sample Standard Deviation: Minimum -Characteristic Resistance Force: K n= 10 f = 2.262 F= 471 lbf SF= 43.981bf F'= 439.5lbf SSSS•• SSSS• • SSSS• • .e.e . . . . ...... • •••• •.•• •.e•• • •• • .• • • Tropical Chevrolet Cleary Inspection Services, Inc. 8880 Biscayne Blvd. Tel. (561) 722-9881, Fax (561) 582-8039 Miami Shores, FL Email: clearyinspections@kcwand.com TEST INFORMATION: Roof "B" Test Date: 11/24/2014 Number of Test Conducted 13 *Note the Location of all tests on 'Building Information', attached. FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET Deck: Steel * See TAS 105-11 to determine number of tests ROOF "B" SAMPLE NO. FLAN IDENTIFIER MTIAL FAILURE LOAD FIELD PERIMETER CORNU 1 T1 450 X.... •• • 2 T2 400 X 0.00•• •• 3 T3 550 0000.. X 4 T4 450 X'....' 0000.0 5 T5 500 X 00.00• 0.00 6' T6 420 X• o 0 sees 7. T7 425 X: 8 T8 480 X 09600 9 T9 415 0• X 6966 • 10 T10 420 X 11 T11 475 X 12 T12 500 X 13 T13 490 X STATISTICAL ANALYSIS: ROOF "B" No. of Tests 't' Estimator Mean Failure Load: Sample Standard Deviation: Minimum -Characteristic Resistance Force: Sincerely, Cleary ' ns Service, Inc. Katherine I. Cl Miami -Dade Lab Certification No. 11.0211.01 3 n= 13 t' = 2.179 F= 459.6lbf SF= 42.131bf F'= 434.1lbf 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. 0000.. I �Ilz RN. Sailappan, P.E. Florida Registration No. 46696 Y ' r .0.. .. 0000 0000.. 0000.. • • 0600.. 0000.. 0000 ..40. 0000 0000 0000. . . 0000 0000 . . .4606. 0000.. 000000 4 .. 0000.. 0 • . .. . . . 0000.. 0000.. Y ' r Cleary Inspection Service, Inc. Telephone (561) 722-9881 Fax (561) 582-8039 Email: clearyinspections@kcwand.com Notes: 1. Use of the results herein to determine the required number of fasteners for insulation attachment or an acceptable anchor or base sheet fastener spacing, as outlined in TAS 117, shall utilize the minimum characteristic resistance for (F') determined in compliance with Section 9 of TAS 105. No margin of safety shall be applied to field withdrawal resistance test results determined in compliance with TAS 105. 2. A safety factor of 2 to 1 shall be applied to all results of laboratory testing. 6 6 0000. 3. The following pages shall be completed for each roof area and' : :00000 � ,••••• • 00 6 included with all Field Withdrawal Resistance Test Recording"ts. 0 •.. • 0000:. .000000 . . . 0000 9 0 0000 :0906: . 0000 0 9000 9909. 0000.. . . 0000 0000. .. .. 0000 0000.. Tropical Chevrolet .. 9 6 6 9 0• 9 8880 Biscayne Blvd. • 9 6 • • •• • • 9969 Miami Shores, FL ••�• ; ;6696 6�•� Test Date: 11/24/2014 Soso Roof Area Building and Parapet Heights. (If no parapet exists, "N/K) Roof "Afl N/A 26' Ground Level Page 4 Roof "B" and Level 'Building Information Sheet' Tropical Chevrolet 8880 Biscayne Blvd. Miami Shores, FL Test Date: 11/24/2014 T 63' T12 T1 T13 T2 31' T1 T2 T3 T3 Slope Roof T4 T4 133' T5 T9 180' 1 Roof "B" 14' T6 T7 T5 T8 36' Roof "A" T9 T10 -A / 70' Cleary Inspection Service, Inc. Tel. (561) 722-9881 Fax (561) 582-8039 Email: clearyinspections@kcwand.com 58' •so•s• • 0 • 0000•0 0606 • 0606 • • T11 ••06••00 0 e• see*:* •0000• • .... .... •••s•• • . 3...... .... ..... T� osses goes 00.0.0 • Roof 6i Bf1 • 00. 0 0 0 • • • • • • • 00.01• •0000• T10 .. gee ' .... 0 0000 18' 0 0 • T8 I60' M NOT DRAWN TO SCALE Drawings & measurements are approximate representation of field layout Page 5 CERTIFICATE OF CALIBRATION . TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY AND PERFORMED IN ACCORDANCE WITH IS010012-2003 THIS DEVICE IS CERTIFIED TO BE WITHIN +/- 0.5% OF FULL SCALE READING AT EACH TEST POINT AT THE TIME OF SHIPMENT CERTIFICATE NUMBER: 21367 CALIBRATION DATE: 8/18/2014 PART AND CUSTOMER INFORMATION ,..:dam• q. MODEL #: DFG2W2000 SERIAL #: 20606019 CUSTOMER: CLEARY INSPECTION SERVICE CUSTOMER#: CLE33460 ? r' •� ' + F s {R a i �S. CALIBRATION DATA Calibration not valid without CERTIFIED stamp and initials APPLIED EXPECTED FULL VALUE VALUE RUN AVERAGE • SCALE (LB) (LB) (LB) ERR4V.•. 0.00 0.00 0.000 ...... 0.0tr0 0..0 0.001 ...: 200.00 ;�• . 400.00 400.00 394.000 • • • • . 394.080' • • • . -0.300% 600:00 0000 0••• 00.00 800.00 800.00 797.000 ...... 797.0%% -0.15Q°�•... 1000.00 000000 . .• 1200.00 1200.00 1205.000 • 0 ;205.0n..:. 0.250%o • 1400.00 ; ••. • �.�.• 1600.00 1600.00 1605.000 0 0 0 0 *1 605.09q 0.250% 1800.00 . 2000.00 2000.00 2007.000 2007.000 0.350% CALIBRATION EQUIPMENT USED SERIAL #1: 21404075 SERIAL #2: CAL EQUIP: COMTEN INDUSTRIES load cell PSB5000, PS85000 S/N 20804027 and CQTM1000 S/N 20408026 were calibrated at Com -Ten Industries. CAL DATE: according to Internal standard and conforming 4122!2014 to ISO/IEC 17025 and ANSI/NCSL Z540.1. The uncertainty Is 1.33 Lbf. Report No:21404075A0422 THIS EQUIPMENT IS CERTIFIED TRACEABLE TO THE UNITED STATES NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY. CONDITIONS TEMPERATURE 75°F RELATIVE HUMIDITY: 28% AS FOUND NOTES: ( * Indicates that the part was out of tolerance) VALIDATION ,..:dam• q. CALIBRATION PERFORMED::'° BY: CCtivjp ? r' •� ' + F s {R a i �S. Calibration not valid without CERTIFIED stamp and initials 640549th Street North, Pinellas Park, FL 33781-5724 * 727-520-1200 * FAX 727-520-0299 E -Mail: sales@com-ten.com * Web: www.com-ten.com E 0.0• .. . 0000 00 0.0. . . . 9 0000.. .9.i.. 9 000000 ..•. 9000.0 0..00•.90. 09.9. 0... 0..0 0.00• 0 9 . • 0000 0000 • • 0000.• • ..0..0 0 00 .... :0 • . 0 • .. • .9 • • • • i • 000000 .0.9.0 E F MIAMI -RADE n, ,- a �Y,�F� Al MIAMI -DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Florida 33175-2474 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidadeggy/economi Johns Manville Corporation 71717'" Street Denver, CO 80202 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) • • reserve the right to have this product or material tested for quality assurance purposes. V thio Produolt•or • • • • • material fails to perform in the accepted manner, the manufacturer will incur the expengs of s$ch teoing • • • and the AHJ may immediately revoke, modify, or suspend the use of such product or matwis&withi$ tpleir' ....:. jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by MDade County �. Product Control Section that this product or material fails to meet the requirements of Wfticablq "". • 0000 0000 0000• building code. •••••• •••• ••�••' This product is approved as described herein, and has been designed to comply with thbTlhrida Buildeing Code • • • • including the High Velocity Hurricane Zone of the Florida Building Code. • .0000. DESCRIPTION: JM TPO Single Ply Roofing System over Steel Decks.009 .6000. •. 0 •00. LABELING: Each unit shall bear a permanent label with the manufacturef's name or logo, city, sate land following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 12-0605.02 and consists of pages 1 through 25. The submitted documentation was reviewed by Jorge L. Acebo. . LyJ NOA No.: 13-0828.04 Expiration Date: 12/24/14 MIAMMADE CO tM Approval Date: 02/20/14 ,...• � —11191 ? Page 1 of 25 r ROOFING SYSTEM APPROVAL Category Roofing Sub -Category: Single Ply Roofing Material: TPO Deck Type: Steel Maximum Design Pressure: -105 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description JM TPO 45 45 mils thick ASTM D6878 Polyester reinforced Thermoplastic TAS 131 Olefin single ply membrane. JM TPO 60 60 mils thick ASTM D6878 Polyester reinforced Thermoplastic TAS 131 Olefin single ply membrane. JM TPO 80 80 mils thick ASTM D6878 Polyester reinforced Thermoplastic • • TAS 131 Olefin single ply mimbrke. • • • • • • JM TPO FB 115 60 mils thick ASTM D6878 TAS 131 Polyester reinforced,•fle®cae bacW,..' Thermoplastic Olei %1*e ply - membrane. 4,•,. •, •,a.., • JM TPO FB 135 80 mils thick ASTM D6878 Polyester reinforcedv Mew backed. . . � � ; � � • TAS 131 Thermoplastic Olefin single ply..:. . , .... membrane. • ° • • • • • JM Urethane Insulation 1 gal. Proprietary A one part, cold-aWlie4 adhesile • • • ° • • Adhesive .. . .... JM Two Part Urethane Various Proprietary A two -component, cold -applied • • • Insulation Adhesive adhesive JM TPO Membrane 5 gal. Proprietary A synthetic rubber -based adhesive used Adhesive (Solvent -Based) on single ply roofing membranes. JM TPO Membrane 5 gal. Proprietary A synthetic rubber -based adhesive used Adhesive (Low VOC) with fully or partially adhered TPO roofing membrane systems. JM TPO Membrane 5 gal. Proprietary A polymeric, wet laying (single side Adhesive (Water -Based) application), low-VOC adhesive. JM TPO Primer 3 gal. Proprietary A synthetic polymer -based. primer. JM TPO Primer 3 gal. Proprietary A low VOC, synthetic polymer -based (Low VOC) primer. JM TPO Walkpad 552" x 30" x 50' Proprietary Textured walkway protection membrane JM TPO Detail Membrane 24" x 50' TAS 131 Non -reinforced membrane for wrapping pipe flashings and vertical stacks and for waterproofing joints of JM TPO Coated Metal. NOA No.: 13-0828.04 Expiration Date: 12/24/14 Approval Date: 02/20/14 Page 2 of 25 W 00.0 .. sass • sass.. •0000e . . . . sass.. asses. . 4 4 .ease. .6.. •0.9e e•.• seas seas• .ass • . ••.tea 6s6ees .•6• s • • • 009.0• • .• 4609.9 .a a •• • • • • • • assess 00..00 W Membrane Type: TPO Deck Type 2I: Steel, Insulated Deck Description: Min 18-22 ga., 80 ksi steel decking attached to steel supports spaced 6ft. o.c. using Traxx/5 fasteners spaced 6" o.c. (at the bottom flute) and with side laps fastened with three Traxx/1 screws spaced evenly between supports. System Type D(1): Membrane attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. The following assembly is approved to a maximum design pressure listed with specific fastening patterns. No substitutions shall be made. Base Insulation Layer Insulation Fasteners Fastener Density/ft2 (Table 3) ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R Panel, R Pane125 PSI, ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI, ENRGY 3 CGF, ENRGY 3 CGF 25 PSI, ValuTherm CGF, ValuTherm CGF 25 PSI, ENRGY 3 FR, ENRGY 3 FR 25 PSI • • Minimum 1.5" thick Top Insulation Layer (Optional) Insulation Fasteners Fas '•Aensiti7fi.' • • (Table 3) • • • • • • • *of •••• DensDeck, JM SECUROCK Gypsum -Fiber Roof Board, Invinsa Roof Board *:6000 • 00000 Minimum 114" thick N/A • • • •Na • • Note: All insulation shall have preliminary attachment, prior to the installation of the roofMit membrane at a minimum application rate of two fasteners per board for insulgtion toard s having no dimension greater than 4 ft., and four fasteners for any insulation board having jio dim Win greater than 8 ft. " • seat Membrane: JM TPO mechanically fastened to the deck through the insulation as destribed below; side laps are sealed with a 1.5 -inch wide heat weld. Fastening #1: Membrane is mechanically attached using High Load fasteners and plates spaced 6" o.c. within laps of an 8 ft. wide sheet. Maximum Design Pressure -52.5 psf. (See General Limitations # ;9 Fastening # 2: Membrane is mechanically attached using Extra High Load fasteners and plates spaced 12" o.c. within laps of an 8 ft. wide sheet. Maximum Design Pressure -45 psf. (See General Limitations # 7) Fastening #3: Membrane is mechanically attached using High Load fasteners and plates spaced 6" o.c. within laps of a 10 ft. wide sheet. Maximum Design Pressure -45 psf. (See General Limitations # 7) Fastening #4: Membrane is mechanically attached using Extra High Load fasteners and plates spaced 12" o.c. within laps of a 10 ft. wide sheet. Maximum Design Pressure -45 psf. (See General Limitations # 7) Fastening # 5: Membrane is mechanically attached using Extra High Load fasteners and plates spaced 6" o.c. within laps of a 10 ft. wide sheet. Maximum Design Pressure -52.5 psf. (See General Limitations # 7) Maximum Design Pressures: See Fastening Pattern. (See General Limitations # 7) NOA No.: 13-0828.04 Expiration Date: 12/14/14 rGMI-naue COUNTYM Approval Date: 02/20/14 Page 21 of 25 STEEL DECK SYSTEM LIMITATIONS: 1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137, calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. 2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gage attached with 5/8" puddle welds with weld washers at every flute with maximum deck spans of 5 ft. o.c. GENERAL LEVIITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. ...... 4. An overlay and/or recovery board insulation panel is required on all applicatift evIr clokd c; ll foam •. insulations when the base sheet is fully mopped. If no recovery board is used the bass.sleet slVd?Jv•applie•.d„..;• using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip me4ad 8" ribbons in three • • • rows, one at each sidelap and one down the center of the sheet allowing a contipms. area af•uentilatior. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in eWribbon to fIIUw crosq: • • • ventilation. Asphalt application of either system shall be at a minimum rate of* f l �lt:Jsq. • •l 186. Spat . .. • attached systems shall be limited to a maximum design pressure of -45 psE • • • • • • • • 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic 174ce tF'valug of 2.75 lbf.,... •: • as tested in compliance with Testing Application Standard TAS 105. If the fastenerovalu e,•as fie=d tWd, are. • • • • below 2751bf. insulation attachment shall not be acceptable. • • *see • 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based6i a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance*audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-0828.04 �aaE counmr Expiration Date: 12/24/14 rpArt► E Approval Date: 02/20/14 Page 25 of 25 i•.6 .. . 0000 ..0006 • • • • s 00060 6.60 ...6.. 600069 .••. 00600 •..• •.6i •.061 to*:** • •s ....e. •i • •. • • • . • • • • e iii•.• 0000.•