RF-15-826Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
inspection Number: INSP-232112 Permit Number: RF -4-15-826
Inspection Date: May 18, 2015 Permit Type: Roof
Inspector: Rodriguez, Jorge
Inspection Type: Final Roof
Owner: LOPEZ, AMALIA Work Classification: Flat
Job Address: 54 NW 103 Street
Miami Shores, FL 33150-1234 Phone Number (786)299-3446
Project: <NONE> Parcel Number 1131010180040
Contractor: AMENGUAL ELECTRIC INC
Building Department Comments
RE ROOF FLAT
Infractio Passed Comments
INSPECTOR COMMENTS True
Passed 2it
Inspector Comments
Failed El
Correction
Needed
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
For Inspections please call: (305)762-4949
May 18, 2015 Page 1 of 1
p
A
Project Address
Miami Shores Village
10050 N.E. 2nd Avenue NW
Miami Shores, FL 33138-0000
Phone: (305)795-2204
Parcel Number Aoollcant
54 NW 103 Street 1131010180040 AMALIA LOPEZ
Miami Shores, FL 33150-1234 Block: Lot:
owner mrormauon Address Phone Cell
AMALIA LOPEZ 54 NW 103 Street (786)299-3446
MIAMI SHORES FL 33150-1234
54 NW 103 Street
MIAMI SHORES FL 33150-1234
Contractor(s) Phone Cell Phone
AMENGUAL ELECTRIC INC
of Work: Re Roof
onal Info: RE ROOF FLAT
ification: Residential
nina: 3
Fees Due
Amount
Bond Type - Contractors Bond
$500.00
CCF
$3.60
DBPR Fee
$4.13
DCA Fee
$4.13
Education Surcharge
$1.20
Permit Fee - New Roof
$275.00
Scanning Fee
$9.00
Technology Fee
$4.80
Total:
$801.86
Valuation: $ 5,200.00
Total Sq Feet: 1200
Pay Date Pay Type Amt Paid Amt Due
Invoice # RF -4-15-55143
04/09/2015 Check #: 9460 $ 50.00 $ 751.86
04/14/2015 Check #: 1051 $ 751.86 $ 0.00
Bond #: 2672
Avauaoie
Inspection Type:
Roof
In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations
pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In
accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are
required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work.
OWNERS AFFIDAVIT: I certify that all the foregoing information is ac te-arsQ of ork will be done in compliance with all applicable laws regulating
construction and zoning. Futhermore, I authorize the above-rAkmed ntractor to do stated.
April 14, 2015
Authorized Signature: Owner / Applica / Contractor / A Date
Building Department Copy
April 14, 2015 1
r r • j - -
Miami Shores Village
APR 0 9 2015
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 _ -
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION UNE PHONE NUMBER: (30S) 762-4949
FBC 20 d
BUILDING Master Permit NoL'�— Y—�-6
PERMIT APPLICATION Sub Permit No.
❑BUILDING ❑ ELECTRIC OOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL
❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS:T%�
City: Miami Shores County: Miami Dade Z)o: �ZG�
Folio/Parcel#: z: �/ �� ��� Is the Building Historically Designated: Yes NO
Occupancy Type: Load: Construction Type: �� = - Flood Zane: BFE: 6� FFE:
OWNER: Name (Fee Simple Titleholder): 41)la ' k Z�ze� Phone#:
Address: , ,
City: -44 f"— 44-; " 8 4 1'k' -J State:
Q
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company /P/� Phone# : ��"�`/6 ��C�`
Address: 97�)—/ �k � �S
City: _� 1� f
Qualifier Name:
-State Certification or Registration M (::�6C
DESIGNER: Architect/Engineer:
of Competency #:
V16 V/ ae
Address: City: State: Zip:
Value of Work for this Permit: $ Square/Unear Footage of Work: zoo
Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition
Description of Work: /f- -to� V4
Specify color of color thru tile: n
Submittal Fee $ Permit Fee $ L�� CCF $ CO/CC $
Senning Fee $ Radon Fee $
DBPR $
Notary $
Technology Fee $ Training/Education Fee $ Double Fee $
Structural Reviews $ Bond $ � Q
TOTAL FEE NOW DUE $ IL)'
(Revised02/24/2014)
Bonding Company's Name (if applicable)
Bonding Company's Address
City State t"
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
Zip
City State Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or Installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the Issuance of a building permit with on estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment Also, a certifed copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. in the absence of s h posted notice, the
d. /
inspection will not be approved and a reinspection fee will be charge] /
Signature
OWNER or IVENY
The foregoing instrument was acknowledged before me this
5i day of ��'� 20L4 by
Z0P ,>- who is personally known to
me or who has produced
Identification and who did take an oath.
NOTARY PUBLIC:
AMAI-1
Print:
ORGE ROSSEAU
Seal: COMMSION #FF119045
EXPIRES May 4, 2018
(407) 39 53 FI oridallotmySavicecom
APPROVED BY
(Rev1sed02/24/2014)
as
CONTRACTOR
The foregoing instrument was acknowledged before me this
-10 day of _ r /-/ 20 AJ , by
Afllt'-w �'' __,who is personally known to
me or who has produced as
0er#ficatlon and who did take an oath.
NOTARY PUBLIC:
Sign:,
Print: JORGE RO
r MY C OMMSION #FF119045
Seal: EXPIRES May4, 2018
(P-F39�8M-0153 FloridaNc4myServica:c�
0�
isI�� Plans Examiner Zoning
Structural Review Clerk
---
CERTIFICATE OF
aee
INSURANCE 419/2015
roiducer. Piy outh Insurance Agency .
This Catulate Is linued as a m&tWof 11110mom onlyand odes I*
2739 U.S. Highway 19 N.
Holiday, FL 34691
ThIs amend,
cw atterthecoverageafforded by the potibbelow.
(727) 938-5562
hwers Affording Coverage
Insulted: South East Personnel Leasing, Inc. & Subsidiaries
2739 U.S. Highway 19 N.
Holiday, FL 34691
In A_ Lim I ran W 11075
Insurers,
I
insurer 0:
Coverages
ee owr sn Haar a lndlr�tot. e� re �m ar n argr _ or
t fit re tavfil�t ihia msyba may the afforded by the pol adit fW� is _ to alt ftt&ftk awhwoft> WWWWWWWor suthpowes, AWOOM
riftft VWM RM 1120 been raducsd toy paid ftft
INSR
LTR
AiiGl
INSRD
Type of Insurance
Porcy Number
Date
poliw 5pira"
Date
Limb
(WODW)
.......... .
MiDDNY)
GENEMILLIMILITY
ter+
commercmGeneral 1. aw#y
t; wms made 13 occur
Ditnmaemre a1 +
�ourrera�i
mod L�!pv
Pe.,
sonalAdvIn wy
t�� aggregate IImit applies per.
Poky
Clete
01MOBILE UAB1LiTY
Simla Una
AWO
Ali 0 mad Autos
Scheduled Autos
(F-A
Orp
i3od�tr Injury
HMAts a
t
EXCEBSIUMBRELLA1.t
SI ITT
esc+tc> m
.
ROD=
13 c'sh" "aft
A
Workers Compermation-and
Employers' Llabt ty
Any p"fietor/pafterhorembheoft edmember
WC 71949
01MV2015
01101120111
x
YiIO Statu-
to urlds
OT1
EFi
E.i.. Eft Acddard SIA001000
E.1-Disem-EgEnvWyee St teFO t# ?
mduded? MA
0 Yes, desafto under protisiona
E,L. Disease - Policy tiattt3 41,i�ot#M9
OtIW
IJ*n Insuilrante Le= Is A.M. Beck Company rated A Lb!ent . AMB * 126LG
d OporayU�o..nsil.+{ oUon*NehlcleWExoit lo�nss added by pielt 10, 920-589
se entl3podal Provisions:
�on�s�yogf
�E.�n�d(o
pd�r,
p/yq � M A
Ayi,Yerapryry"'„"'��7��`��Y�plIes to 6WYG el�l�}ii yWs)'of east el K'Wngd 34 Rr., & .9bl;Wfanes UW are' to the ien : PW
7Roofing
Roo Gmerd 6anwaor
�{.�
ual t C, IM
Covemp only apPlies 0 InOW incurred by South est Peronnel WaOm Inc. & Subs ee(sh While =ftV in: FL.
Caverap does not fpr to SKfty enployee(s) or frWepsnilent cos) of the ClIsit COOParny or WW other
A fit of the acre employee(s) Wand to the Clot Cornpany can be obtained by Wv a requet to (727) 937.2138 or by ca8ing (727)938-962.
P Na1r
ISSL E:04-08.15 tai
tORTik A 140MR _ CANCBt 1 !ii t#N
VtiLLAGE dK =I S FtES
ul4 anYaf d Da edtratore Ure deleUtatdot
ln�sror axils o ml3a days avrl#an Nttt��eGflce$o ho7ba toiirete ittrittre to
do sfl shefl impose fro oDl or ileblltY oratry �ttd uptna doe Insurer, i� : ar relit:
10050 N.E. 2nd AVE.
MIAMI SHORES, FL 33138
+�
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
AFFIDAVIT OF COMPLIANCE WITH ROOF TO WALL CONNECTION HURRICANE MITIGATION
RETROFIT FOR EXISTING SITE -BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PURSUANT
TO SECTION 553.844 F.S.
property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential
Structures as adopted by the Florida Building Commission by Rule 96-3.047 F.A.C.
boz��
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this �� day of A y C 20 A—
Notary Public, Sate of Florida at Large
JORGE ROSSEAU
MY COMMSION #F I M45
SEAL
E"IREs N* 4,2018
F(4M 398-0153 FMd&NamrySaviCe.com
Revised on 5/21/2009
FINAL COMPLIANCE
To: Miami Shores Village Building Department
0000
Date: ` • •
0000:0
.
10050 NE 2nd Ave
.
'.0' : 1111
1
Miami Shores, FI 33138
0000.. 0000
•
0000..
0000..
� 0 0 • � • � 0
1
Re: Owner's Name:
Property Address:
lV ��
�... 0000
�• •; �, .' •.
0000.
0000.
0000 0000
0000..
Roofing Permit Number:
;••;•;
'.
. . . .
.0010.
0000..
..
11 . 1..1
0000..
Dear Building Official:
00:6
I �� ��
certify that I have improved the roof to wall connections of the referenced
property as required by the Manual of Hurricane Mitigation Retrofits for Existing Site -Built Single Family Residential
Structures as adopted by the Florida Building Commission by Rule 96-3.047 F.A.C.
boz��
Signature Print Name
State of Florida
County of Dade
The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned.
Sworn to and subscribed before me this �� day of A y C 20 A—
Notary Public, Sate of Florida at Large
JORGE ROSSEAU
MY COMMSION #F I M45
SEAL
E"IREs N* 4,2018
F(4M 398-0153 FMd&NamrySaviCe.com
Revised on 5/21/2009
FINAL COMPLIANCE
SECTION R4402.13
HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING
CONSIDERATIONS
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1. -44 Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the pti Wse of
providing that the roof system meets the wind resistance and water instruction perfordianae standards '
.Aesthetics (appearance) are not a consideration with respect to workmanship provision: 1�ethetic js�spgs�
such as color or architectural appearance, that are not part of a zoning code, should In 6d*ssed as part of
the agreement between the owner and the contractor. 00000 069•
0000 0000
2. Renalling wood decks: When replacing roofing, the existing wood roofideokgay hale to'q
renailed in accordance with the current provisions of Section R4403. (The roof deck is, esudly conceded prior
to removing the existing roof system). :00:0: '
3. Common roofs: Common roofs are those which have no visible delineatar:WVeen neigr Ung
units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor 44Qr
owner should notify the occupants of adjacent units of roofing to be performed.
4. AExposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can
be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appearance.
S. Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. VOverfiow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not
overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. ,Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly (the building itself). Thoe)ds ng amount of attic v ntilation shall not be
reduced. It may be beneficial to consider additional vench can res in nding the service life of the
roof.
Owner/Agents Signature t Tactor Signature Date
Revised on 7/9/2009 LD
0000..
0000..
0000..
0000.
00000
0000.0
000000
000000
Scadon C
MIAMIMAD Mlaml-Dade County HVHZ Electronic Roof Penult Form
(j Section C Page (Low Slope Roof Systems)
"Dellvering Excellence Every My -
FYI In the specitic roof assembly components. !f a component is not required, insert not applicable (n!a) In the text box.
ROOF SYSTEM MANUFACTURER: I GAF Top Ply.
LW,MINERAL CAP
Product Approval (NOA): 14-0611.01Type:11
System
Top Ply Fastening / Bonding Material:
Wind Uplift Pressures, From RAS 128 or Sealed Calculations:
(P1) Field: -42.8 psf
(132) Perimeters: -71.7 pef
(123) Comers: -108.0 psf
Maximum Design Pressure From NOA -52.5 psf
Roof Slope: 0.50 ": 12 Roof Mean Height: 18 it.
Parapet Walls: 0 No W Yes Parapet wall Height: t
Deck Type: —5/8" Plywood—
Support Spacing: " o/c
Alternate Deck Type: I NA
Existing Roof:
SAME
Fire Barrier.
NA
Vapor Barrier.
F777
Anchor Street
GAF GLASSBASE 75#
Anchor Sheet Fastener / Bonding Material:
1-1/4" RS NAIL & TIN CAP 1-5/8"
11. t—$ O . INSULATION I
Insulation Base Layer Fastener / Bonding Material:
HOT MOP ASPHALT
Insulation Top Layer Size & Thiclmess:
NA
Insulation Top Layer Fastener / Bonding Material:
NA
Base Sheet(e) & No. of Ply(s):
Base Sheet Fastener / Bonding Material:
A Lo 05, -
Pty Sheet(s) & No. of Ply(s):
GAF RUBEROID 20 (1) PLY
Ply Sheet Fastener / Bonding Material:
HOT MOP ASPHALT
HOT MOP ASPHALT
Surfacing: IRRANULES
SINGLE PLY MEMBRANE:
Single Ply Manufacturer / Type:
NA
Single Ply Sheet Width: El " 112 Sheet Width: ; ...
No. of Single Ply 112 sheets: . • • • • • •
Single Ply Membrane Fastening / Bonding • WWt • •:. • •
NA ••O••• •.
D FASTENER SPACING FOR BASESHftrATfACHmha• • •
❑ SINGLE PLY MEMBRANE ATTACHmml • • ; . ".
seen
1. Field: r97-1" o1c @ Laps & r27 rows 9.. -r o% •
e •
2. Perimeter. " o% ® Laps & r47 Qows " oia • •
3. Comer. r67 "o%® Laps & rows 6 "o% •.;.
NUMBER OF FASTENERS PER INSULATION BOARD:
1. Field: El 2. Perimeter. El 3. Comer.
Insulation Fastener Type:
NA
WOOD NAILER TYPE AND SIZE:
rX 6" PT WOOD
Wood Nailer Fastener Type and Spacing:
#12 WOOD SCREW 16"OC
•
Ones 00
0000•
0.000•
EDGE & COPING METAL SIZES:
Edge Metal Material: —Galvanized Metal—
Edge Size: —3" face 26 ga.—
Hook Strip Size:ALECT Size:--SELECTEDGE METAL HOOK STRIP SIZE—
Edge Metal Attachment:
1-1/4" RS NAIL 4" OC
Coping Material: --SELECT PARAPET WALL COPING MATERIAL—
Coping Size: —SELECT COPING METAL SIZE OR THICKNESS—
Hook Strip Size: —SELECT COPING METAL HOOK STRIP SIZE—
Parapet Coping Metal Attachment
NA
Insulated Nailairle Deck With Edge Nailer
MIAMI -
I
°Delivering Excellence Every Day"
Miami -Dade County HVHZ Electronic Roof Permit Form
Illustrate Components Noted and Details as Applicable:
Roof Mean Height: 18 ft.
Drip Metal: 11111110-1111
3"X3" GALV 26G' • • • •' • • •
goo
Top Ply
Interplies
Base Sheet ',
Continuous Cleat: 0 0 0 0 .. ..:. 00604
080900 • 0000
F• • • • •
Surfacing: 0000 •••• 008
0000
GRANULES 000060 • • • • • •
-
9
99999
Top Ply: . . 0000
9
Anchor Sheet
GAF MINERAL CAPSW FU � 0.0 ; •
•
9999
Interplies:
_—
__.. __,000_0_.-•�i _._..._....,„,0000----0000.._ __-..__.____
Drip Metal
GAF RUBEROID 20
Base Sheet:
r
NA
Continuotis
Cleat
Top Layer of Insulation:
NA
Wood Nailer
- 4
Base Layer of Insulation:
F-VTO _ INSULATION
hoof Deck .._.
a
Wood Nailer:
Base Layer - �`
"X6” PT WOOD
of Insulation
Top Layer
of Insulation
Wood Nailer Fastening:
1#12 WOOD SCREW
Anchor Sheet:
GAF GLASSBASE 75#
Deck Type:
PLYWOOD 518"
its. OadU KC
llaclllro: lug
- --A*- . VA .
Inwlattoa (Opttanai)a -- Ariy thickness periita or wood fiber or giass fiber or poty►eocyarrorate mechanically fastened or adhered with
aMa tm. aOhdsoad laahaatng Syatek„ or � ha nqulanorh adhwve,
ease sheets »one ply Type Gat "BAFGLILR® 87S gene Sheet" or "IM•Ply MTS Gast Shit" mechanically fastened
Plysheets — One a two piles hype 61 "6APGLAR� Ply 4` or Tri•PIy 4" Or '+WAFgJ15� Plea MY 6" Or Type 62'Y;APO AS® 075 Base
Sheet" ar Td•Ply 879 eieUe Sheat' R�qy adha�f wNh hot =odMg asphalt
Cep sheat — One piyTyps 83 "QAFG1g5®MUae�at Surfaced Cap Sheet" IVih► adhered with hot =ooflno asphah
1i11rfaCirtgs—'iOPf:OATrs ola11p or TOPCOAT®149Pius -Whitt" or'7tablx 322" applied at a rate of 2.oel/1O fe.
17. Dein C-15/32
ZnCR=1%2
llnsulydfon (opfJonaf)r — Any thlekeoss partite or wood fiber or Sloss fiber or peter to aethaniealty fa amd or adhered with
OMG Ina. "OIVBond Pastsift System" ar any UL Classified irisuheton adhesive.
Budd Aoatdl — HIIIIIlWrll %-IIU tbltk GEOT *PacRc Gypsum U.0 "DaasOede RoWhosrd" or %msneck pdme& Raafboard" or
"DartsDeztc D=GUard- Rootboard" oat Rout(r{mytWnwm W -In. thick Untied States Gypsum Corp.'AWRMQD RBoard" (type Boa(type FRX•G) or
UL Clossilled nadhve widr kaSWM
le oftlta In harder board �etaogered andnlmum of O6 -In. tromp plywood dSechcejo"Udsaly
Base sheets — One ply Typo 02 "GAPGLAS® M Base Sheet" or Td -ply M7S Baso Shed" machanIcally famenad
Ph Shaab— One or two PRO TWO 01 "GAFMAB® Ply 4• or'M-Ply4" er *GAFmAS® Flax Ply 6" or Type 92 "GAPGLASS 875 Bess
Sheet" or Td -Ply 879 Base Sia W rally adhered with hot rooflno asphalt
Cap sheets — One ply type 69'OAFM ASO Mineral SuKased Cep Sheer' fihUY adhered with hot MWOM aWIM 090000
Surfaehhgt — TOPCOATO EneroyCobe'" or "MMT* Me Plus - White" or "Matrtx 322" applied at a raft of 7a9e1/1oD-eta. 0600
I& Decb NC =ncUam l • • • 0 i • • • •
•
or
ply
"BAP—oor
•••••• ••••
0MG IML Y sqa — Airy tblekneas pW tt or wood fiber er otass fleer or pWyisdeyanuratt mechanically *o0r*atfl�ared with
aria 8heSV~ or UL Ciassifiad insulation adhesive, ryes G2 fully adhered with hotdaoirg asphalt see*
att ne CaAAGLSyAB® stratayahie tsomtnatar Vantirta Baso sheet"
Pty skaab "" Ono or two pbs'Rubaold® Mop Smstth" or "Ruberold(b Mop Smooth 1.5" ar"Rubarolde Mop Sfioa�h PIS' a • • , • •
'9tubarold® lir Or'7tubald® c 20 HT" My adhered with but roofing asphalt • • •
Mmth1hiaTlat —Oce ply "GAMASO Mhl" Smfaced Cap Shaer fuliynow" with hot roofing asphalt „, , . • • • •
sortacbrgr — "POPCOATO Erter9TC4e"'" Or "IMMAT® MB No - Whtte" or "Matrtu 322" applied at a rate of 2,,gAR V • : • •
19. DOW C-15132 lMcitnaa 1 • • • • • • •
=nsuheto» (optlonal� » Arty thldmesa perlite or wood fiber or glass flbtr or
mechartiCall y • fast�• • • i •
pWyisocyamrrata ped or edhan+ed auM
OMG Irre. "Dtyaend Fasterihty S " or arry uL Ctassifled insulation adhesive. • • •
B+srrNer Boards —Minimum t�thltk Geoeole-Pectic gypsum LLC •DauOack® Rtotbeard" or "Danstta* Pdmdq qdmaDaW or 0000
"Dell6Dedt DureGuatad1 RcWborlyd" or ntlntmum Ya -in, thick Untied Status Gyps Corp, CIIII Roof Board• L G) of •
'"S6CUROCK® Giass•Mat Roof Board° (type i m anlCaRli fastened ar amta<ad with 0146 inc. "OlyBortd Fastai tsg Syatam`
UL Cia6slRed trtsuletoe adhuislya writth fault joints to the hamar board products atagoerad a mWmum of 6-tn. from plywood dock joinbL
ease flhea>h —One ply'YiAFGLasQI Stratavertt BitrNnator Vantinp Baal sheat• fury adhered with tau rooting asphalt
Pty Sheets"" One or two piles "Ruberaid® Mop Smooth" er "Rubaold®Mop smooth plus• amy adhered with hot roollog asphalt
Membharses One ply "GASM A5W Mineral smfatad Cap Sheat' fully adhered with hot MORN asphalt
sprfacings —'TOPCOAT® fine WCote""' or "TOPCOAT® MB Plus - WWte" or "Matrix 322" applied at a ram of 2-90l/iCO re.
20. Decld C-15/32
Inelinet 1
Batas WWAW •- 011e PIYTWW G2 WFGLASO 873 Base 5heWer Td-PIy0 am Base Sheat" medeanrosilY fastened.
Rzffe!R
firptlonan= -' Ant adelmws or ambtrtation= paiib ofa�ened
ed or adhered witb OMG tae. "0lyaortd FBstontng Syce— Orta or more puss "Rubereld®20" m "Rubere ®atmehed. — One ppN Type G3 "ItAPO1.AS® Mineral Surtacad Cap' BUR Mhleral 9urhreed Cep Sheet"
Class a
L Deets 0.15/32
=sallnet 3.112
>tnsatotbn (Optbrtans — antes or pore layers penpta ar wood fiberor glass Rbor or potytsacyanurate or urettarte or
pertlta/polylsoeyanurero comPosRt or peNlte/washane aromposite or wood fiber/pWy(socyanurate eamposite or phenolic, any thickness.
PLy sheet —two pr mors pAes Type Gl "GAFGLAS®ply 4" or Td•Piy� Ply 4" or "GAFGLl0.5t9 Ply s" mecltanimuy fastened
Cap tiheeta —Tylia G3 "GAFGLAS@I MUterel5urfaead Cap Shaee" or'?irl-P1yW Mineral SuHaced Cap Sbaet" or "GAFGlASt81 EneroyCap`"
BUR Mineral Surfaa«$d Cap sheat', fuDy adhered with bot rooMo aspheR.
2. Dada C-15/32
indh s 3.1/2
snwtatfoa (OpfinaafN — One or more layent pestle or wood fltrtr or giaffi learn or polyisocVwnni to or urathent or
Per>ne/pWYtsozymturate composts or pertitelurethana composite ar wood tiberJpo►ytsocrarkurate compostm of phenolic, any U*Wa ss,
Bae Sheets—'Rye or more plletTYPe 6t orType G2 or aty�t a3.
ttemhrartet — One ar mora p►4� "Rubatald®Torii Smooth or "IWbarWdd6'fotch GROW or "Ruboroldt Torch Granule Plus" or
"Auber+eld®Ma►p 5urnootb" or "Avbanoldl9 Mop Smooth LS" or "Rubaoid� Mop 8rrwu tie Pius" or "Rubveldsi Mop Granule" or "Rubertld®
Mop P{us Gramme" Or "ROOFMetxh"" SB5 ModU{ed Granular" tr "fd-Ply SIiS ModlRed Bidimera Membrane" or "ROOFMatch- APP
MOdifled Granhrlar" or "1'd-PIy®1r-4!i" ar Tri•Pty(9 TP�4" Or "Rubarold®Dual Smooth."
$urfa0ed fully !adhered with hot reoflng asphalt Mllrheral Stafeced Cap SheW ar "Ci CLAS® EeroyCep- OUR
3. Deet C-18/32
IMUrroh 2-1/2
httpJ/daWximiiL.conVee-bin/XYV/templets LIS` T/IFRAMWShOwpagc.html?namL-=T... 6/27/2013
• ••
••••,
•
••••
•
*see
•• •
MIAMI WIIAl411--DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Straet, Roam 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (ICER) Miaaai, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99
NOTICE OF ACCEPTANCE (NOA) }vnw.mtamdalde.aay/aeon"mv
GAY
1361 Alps Road
Wayne, NJ 07470
SCOPE:
This NOA is being issued,under the applicable rules and rcgulationsgovenning the use of construction
materials. The documentation submitted has been. reviewed and accepted by Miami -Dade. -County RER -
Product Control Section to be used In Miami Dade County and other areas where allowed by the Authodff • .
Having Jurisdiction (AHJ).
. 0000
This NOA shall not. be valid after the expiration date stated below. The Miami Dade E otry ProdM •
Control Section (In Miami Dada County) and/or the AHJ (in areas other than Mian$ 0" County) •
reserve 'the right to have this product or material tested for quality. assurance purposes. I&all'Sjvoduct dV •
material fails to perform in the accepted manner, the manufacturer will incur the expense bf Mob testing* • •
and the. AHJ may immediately revoke, modify, or suspend the use of such product or mate'rfal'w�hin their• • •
jurisdiction. RER reserves the fright to revoke this acceptance,. if itis determined by Mlatn= Dade County ,
Product Control Section that this product or material fails to meet the requirements of Me" spplicakle
building code. 649660
This product is approved as described herein, and has been designed to.comply with the F1oF8a Ituilding �' � e
80
including the High Velocity Hurricane Zone of the FloridaBuilding Code.
DESCRIPTION:: GAF Ruberoid®Modified Bitumen Roof System for Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted Herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change In the applicable building code negatively affecting theperformance of this product.
TERMINATION of thla NOA will,.occur after the expiration date or if there.has been a revision or change in
the materials,, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes. shall automatically terminate this NOA. Failure to comply
With any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number prededed by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done. in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the. request of the Building Official.
This.NOA renews and revises NOA No. 13-0424.14 and consists of pages 1 through 29.
The submitted documentation was reviewed by Jorge L. Acebo.
�j
NOA No.*. 14-0611.01
Expiratlon Date: 11/06/15
Approval Date: 11/06/14
Page 1 of 29
0000..
0000..
00000
0000.
.
0000. 0
000000
000000
0 •
000000
0 0
APPROVED ASSEMBLIES
Membrane Type:
SBS
Deck Type 1I:
Wood, Insulated
Deck Description:
19/32" or greater plywood or wood plank
System Type A(1):
Anchor sheet mechanically fastened, all layers of insulation adhered with
approved asphalt
All General and System Limitations shall apply.
Fire Barrier:
FireOut'" Fire Barrier coating, Versashicie Fire -Resistant Roof Deck Protection
(optional)
or Securock® Gypsum -Fiber Roof Board.
Anchor sheet:
GAFGLAS® #80 Ultunc Base Sheet, GAFGLAS® Stratavene Eliminator`• -*sees
Nailable Venting Base Sbeet, Ruberoid® 20, Ruberoid® SBS He* WAC Smoo1:6 •
or Ruberoid® SBS Heat -Weldor 25' base sheet mechanically fasten8d to accic as .
969.0• 060.
described below. 000000•
Fastening
GAFGLAS® Ply 4, GAFGLAS® FlexPly 6, GAFGLAS®#75 Bor8hiet or apr • Oe
Options:
of above anchor sheets attached to deck with approved annular rint%ftnk nails 6 e 9'
and tin caps ata fastener spacing of 9" o.c. at the lap staggered afid Ul No rovig egg 6
12" o.c. in the field. 00 • e
(Maximmnt Design Pressure --45 psf. See General Lindiddon 0'11• : 6 •6
GAFGLAS® Ply 4, GAFGLAS® FlexPly 6, GAFGLAS® #75 Base Sheet or any
of above anchor sheets attached to deck with Drill -Tee- #12 Fastener, Drill -Tec'; ...
#14 Fastener or Drill -Tec u XHD Fastener and Drill -Tec 3" Steel Plate, Drill' •' •
Tec AceuTrae Flat Plate or Drill -Tec AceuTraco Recessed Plate installed 12"
o.c. In 3 rows. One row is In the 2" side lap. The other rows are equally spaced
approximately 12" o.c. in the field of the sheet.
(Maxinurne Design Pressure -d5 psf. See General Lindiatlon #)
GAFGLAS® FlexPly 6, GAFGLAS® #75 Base Sheet or any of above anchor
sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the
Held.
(Maximum Design Pressure -52.5 psf. See General Limitation #7)
GAFGLAS®#80 Ultima Base Sheet, Ruberoie 20, Ruberoid® Mop Smooth base
sheet attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. In the
field.
(Maxinuins Design Pressure -60 psf. See General Lindtation #7)
GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with
Drill -Tec #12 Fastener, Drill -Tec #14 Fastener or Drill -Tec XHD Fastener
and Drill -Tec 3" Steel Plate, Drill Tec " AccuTive Flat Plate or Drill -Tec
AccuTrae Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c. in the field of the
sheet.
(Maxi nurn Design Pressure -60 psf. See General LinsiMlon #7)
NOA No.: 14-0611.01
MG MJO� Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 7 of 29
geese*
ge 00eg
:sees*
0
.ewes
0
e
66 00:0
egeee6
e 0
Fastening Any of above anchor sheets attached to deck approved annular ring shank nails
Options: and 3" inverted Drill -Tec`" insulation plates at a fastener spacing of 9" o.c. at the
(Continued) 4" lap staggered in two rows 9" in the field.
(Maxinrurn Design Pressure —60 psf. See General Limitation #)
GAFGLAS' #75 Base Sheet or any of above anchor sheets attached to deck with
Drill -Tec #12 Fastener, Drill -Td" #14 Fastener or Drill Tec"' XHD Fastener
and Drill -Tec 3" Steel Plate, Drill -Tec AecuTra6e Flat Plate or Drill -Tec
AccuTrae Recessed Plate installed S" o.e. in 4 rows. One row is in the 2" side
lap. The other rows are equally spaced approximately 9" o.c..in the field of the
sheet
(Maximum Design Pressure --75 psf. See General Lindladon #7)
One or more layers of any of the following insulations.
Insolation Layer Insulation Fasteners Fastener • • •
(Table 3) • JensitylPt1 •
EnergyGuare Polyiso Insulation, EnergyGuard�" Polylso RA Insulation, • • • :"'
EnergyGuare Polyiso RN Insulation, EnergyGuard' RA Composite Poiylso IMMA06A "'
Minimum 1" thick N/A 00000. N/A
0000 •00•
Shvctodek® High Density Fiber Board, EnergyGuardm Perlite Recover Board ' 0 0 0 0' • 6060
•
Minimum %:" thick N/A • • • 0
•• 00 0000
EnergyGuardr Perlite Roof Insulation N/A e :00r: ; N/A • •
Minimum /. thick 000000
Note: All insulation shall be adhered to the anchor sheet in full mopping of apprdved flet aspl alp •
within the EVT range and at a rate of 20-40 lbsJ100 fe. Please refer to Roofing Application • •;
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer Insulation installed as the final
membrane substrate. Composite insulation panels may be used as a top layer placed with the
polyisocyanarate side facing down. GAF requires either a ply of GAFGLAS® Stratavene
Eliminator Perforated Venting Base Sheet laid dry or a layer of EnergyGuare Perlite Roof
Insulation or wood Aber overlay board on all polylsocyanurate applications.
Base Sheet: (Optional) install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS' #80
Ultima Base Sheet, GAFGLAS' Ply 4, GAFGLAS F1exPly 6, GAFGLAS'
Stratavent' Eliminator Perforated Venting Base Sheet (laid dry), Ruberoid' Mop
Smooth, Ruberoid' 20, Ruberoid' SBS Heat Weld"'' Smooth or Ruberoid® SBS
Heat Weld"' 25 directly over the top layer of insulation. Adhere with any
approved mopping asphalt applied within the EVT range and at a rate of 20-40
IbsJsq. (See General Limitation #4).
Ply Sheet: (Optional) One or more plies GAFGLAS' Ply 4, GAFGLAS' FlexPly 6 ,
GAFGLAS® #80 Ultima Base Sheet, Ruberold' Mop Smooth, Ruberoid' 20
adhered in a full mopping of approved asphalt applied within the EVT range and
at a rate of 2040 lbs./sq.
Membrane: One or more plies of Ruberoid® 20, Ruberoid' 30, Ruberoid'EnergyCap 30 FR
SBS Membrane, Ruberoid' 30 FR, Ruberold' Mop Smooth, Ruberoid' Mop 170
FR, Ruberoid' Mop Granule, RootMatce SBS Modified Granular, Ruberoid'
Mop Plus, Ruberoid' Mop FR or Ruberoid' Dual FR fully adhered in an approved
asphalt at an application rate of 251bJsq. 115%.
NOA No.: 14-0611.01
6 Expiration Date: 11/06/15
Approval Date: 11/06/14
Page 8 of 29
•.•.••
••••••
0000..
000**
• 0
.0000
0000..
.0....
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
I
1.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2.
GAFGLASMineral Surfaced Cap Sheet or GAFOLAS40 EnergyCapBUR Mineral
Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 2040 lbsJsq.
3.
Topcoat® Eiastomeric Roofing Membrane, Topcoat`s MB Plus (to be used as a primer with
Topcoat Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at 1 to 1.5
gal./sq.
Maximum
Design
Pressure:
See Fastening Options
sees
•
. . ....
.•..••
•
.
...... .•..
......
0000 ••6•
• • • •
• •I
0000 0
00000000••
• 9I
.00:00
0000••
• • 9 • •
1
00 44 9964
•• 9.44
44.904 •
•
•
• 6• •
••6644'
0000••
• • •
•• • 4646
• 0496•,
• 0j
99••
NOA No.: 14-0611.01
E, xpiration Date: 11/06/15
Approval Date: 11/06/14
Page 9 of 29
WOOD DECK SYSTEM LIMITATIONS:
1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® FlexPly TM 6 when used as a
mechanically fastened base or anchor sheet.
2. Minimum �'/4" DensDecks' Roof Board or YV' Type X gypsum board is acceptable to be installed
directly over the wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved • • • • • •
asphalt, panel size shall be 4' x 4' maximum. s e $000
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell :00-
foam
00efoam insulations when the base sheet is fully mopped. if no recovery board is used ft:ft&e shedt•''
shall be applied using spot mopping with approved asphalt, 12" diameter circles, Xe Vee.! or strip
mopped 8" ribbons in three rows, one at each side lap and one down the center of VIVU rttst allowrnek • s
a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" breWshall be • •
placed every 12' in each ribbon to allow cross ventilation. Asphalt application of JIM s;stem 0 I • -
be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limite�•to �lrazimnm, •
design pressure of -45 psf. :' •: .
S. Fastener spacing for insulation attachment is based on a Minimum Characteristic Fprce 4F5 valui -or
275 lbf., as tested in compliance with Testing Application Standard TAS 105. KdA.Wtejer valuer. e.
as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. . s:.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in co4unction with the maximum design value listed within
a specific system. Should the fastener resistance be less than that required, as determined by the
Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered
Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing
shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and
calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed
by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant
(When this limitation is specifically referred within this NOA, General Limitation #9 will not
be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation 07 will not
be applicable.)
10. Ali products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 61020-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
'NOA No.: 14-0611.01
E*ratlon Dates 11/06/15
Approval Date: 11/06/14
Page 29 of 29
ee.e:s
sees..
:0000:
8 8
0000.
00000
8090:0
e
e
e
..sees
0.000:
0