Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
RF-15-654
yrt�s t4 �S. Miami Shores Village 10050 N.E. 2nd Avenue NW Bond Type - Owners Bond Miami Shores, FL 33138-0000 hF A Phone: (305)795-2204 Project Address Parcel Number Applicant 553 NW 113 Street 1121360211120 Miami Shores, FL 33168-3320 Block: Lot: PAUL &MARIE JOSEPH Owner Information Address Phone Cell PAUL & MARIE JOSEPH 553 NW 113 Street MIAMI SHORES FL 33168-3320 Contractor(s) Phone Cell Phone BLUE PANTHER ROOFING & CONSTF (305)807-1058 of Work: Re Roof onal Info: RE -ROOF TILE ROOF ification: Residential 1inq: 3 Fees Due Amount Bond Type - Owners Bond $500.00 CCF $5.40 DBPR Fee $4.13 DCA Fee $4.13 Education Surcharge $1.80 Permit Fee - New Roof $275.00 Scanning Fee $9.00 Technology Fee $7.20 Total: $806.66 Valuation: $ 9,000.00 Total Sq Feet: 1600 Pay Date Pay Type Amt Paid Amt Due Invoice # RF -3-15-54910 03/31/2015 Cash $ 256.66 $ 550.00 03/24/2015 Cash $ 50.00 $ 500.00 03/31/2015 Check #: 172 $ 500.00 $ 0.00 Bond #: 2651 Available Inspections: Inspection Type: Up Lift Report Tin Cap Final Roof Tile In Progress Renailing Affidavit Review Roof In consideration of the issuance to me of this permit, I agree to perform the work covered hereunder in compliance with all ordinances and regulations pertaining thereto and in strict conformity with the plans, drawings, statements or specifications submitted to the proper authorities of Miami Shores Village. In accepting this permit I assume responsibility for all work done by either myself, my agent, servants, or employes. I understand that separate permits are required for ELECTRICAL, PLUMBING, MECHANICAL, WINDOWS, DOORS, ROOFING and SWIMMING POOL work. OWNERS AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction ang. Futhermore, I autiyerize the aboveltamed contractor to do the work stated. March 31, 2015 AuthorlArd Signature: OwneV / Applicant / Contractor / Agent Building Department Copy March 31, 2015 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑BUILDING ❑ ELECTRIC ROOFING MAR 2A 2015 FBC 2010 Master Permit NoP-.,F- IS- (235'� Sub S - Sub Permit No. ❑ REVISION ❑ EXTENSION E] RENEWAL ❑PLUMBING ❑ MECHANICAL F-1 PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: k%X130 01 tk k143 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): T A� 1.. ®s 1.. r �' Phone#: Address: K S 3 W kQ k kl City:1 1 riVt�7 State: Zip: Tenant/Lessee Name: Phone#:_ Email: CONTRACTOR: Company Name: 1/3 /UP7 ! Z06 Phone#: :30!z]* a /9,529 Address: City: r. -.? i Sate: Zip: 2 ?,/.372r Qualifier Name: Phone#: 10 5'-!&a 4 /0 State Certification or Registration #: e t ell 3a- f 2", Certificate of Competency M DESIGNER: Architect/Engineer: ne#: Address: City: State: Zip: Value of Work for this Permit: $ �� ® 10+ Square/Linear Footage of Work: (6 0o. Type of Work: ❑ Addition ❑ Alteration ❑ New 6] Repair/Replace ❑ Demolition Description of Work: ' 1.i — f 0 0 � (' I , t- t rL 0 Specify color of color thru tile: Submittal Fee $_ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Training/Education Fee $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ ��� Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. .,1 The foregoing instrument was acknowledged before me this day of 20 b, . by Ow0 '.•ps�pp��_, who is personally known to me or who has produced as as identification and who did take an oath. NOTARY PUBLIC: CONTRACTOR The foregoing instrument was acknowledged before me this °Z3 day of "Q1t dwl, , 20 1 % , by ��%AV 9 .O " L�A'oj & . who is personally known to me or who has produced�v��lt�._ :O M< as identification and who did take an oath. NOTARY PUBLIC: Sign: --- Sign: '�-- — Print: tQ�0.�� Print:Q�t�O`.` Seal: MARLON A. ZAPATA Seal: MARLON A. ZAPATA J'410 ���. ,�. n ; Notary Public -State of Florida d�•PRY PO 4 ," a i°; �n-: Notary Public -State of Florida • « , • My Comm. Expires Aug 22, 2016 . c My Comm. Expires Aug 22, 2016 P�;� OF'�(, Commission # EE 195041 A oe �pF Commission EE 195041 k�kk+K�k�k4k�k�kk �k�k*3��tsk ** I It9kTi li QQ;�� M1�kNeeldBMl IrOU�i�iN i�Pialk i� +k�kffiIt l": APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) To: Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE. BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. Miami Shores Village Building Department 10050 NE 2nd Ave Miami Sr Re: Owner's i Date: 'L S Property Address: 5 5 '-; W W \ 1_� ST Roofing Permit Number: Dear Building Official: I certify that I am not required to retrofit the roof to wall connections of my b ' Iding because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the Sou!Florida Building Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the owner for the above property mentioned. Swom to and subscribed before me this Z3 day of 114OLTON— Notary Public, Sate of Florida at Large �.,�.., MARLON A. ZAPATA Notary Public - State of Florida 3 ' ; •_ My Comm. Expires Aug 22, 2016 commission # EE 195041 Bonded Through National Notary Assn. • When the just valuation of the structure for purpose of ad valorem taxation is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wag connection Hurricane Mitigation. Revised on 5/21/2009 3/24/2015 7:16 AM FROM: 7276667637 TO: +13057568972 P. ' CERTIFICATE OF LIABILITY INSURANCE Date 312412015 Producer: Plymouth Insurance Agency 2739 U.S. Highway 19 N, This Certificate is issued as a matter of information only and confers no rights upon the Certificate Holder. This Certificate does not amend, extend Holiday, FL 34691 or alter the coverage afforded by the policies below. Insurers Affording Coverage NAIC # (727) 938-5562 Insured: South East Personnel Leasing, Inc. 8r Subsidiaries Insurer A: Lion Insurance Company 11075 2739 U.S. Highway 19 N. Insurer B: Insurer c: Holiday, FL 34691 Insurer O: Insurer E: Coverages The policies of insurance listed below have been issued to the insured named above for the policy period Indicated. Notwithstanding any requirement, term or Condition of any contract or other document with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate limits shown may have been reduced by paid claims. INSR LTR ADDL INSRD i Type of Insurance Policy Number Policy Effective Date Policy Expiration Date Limits (MM/DD/YY) (MM/DD/YY) GENERAL LIABILITY Commercial General Liability Claims Made 1:1 Occur Each Occurrence Damage to rented premises (EA occurrence) Mad Exp Personal Adv Injury General aggregate limit applies per: General Aggregate $ Policy ❑ Project [:] LOC Products - Comp/Op Agg AUTOMOBILE LIABILITY Combined single Limit Any Auto (EA Accident) All Owned Autos Bodily Injury Scheduled Autos (Per Person) Bodily Injury Hired Autos Non -Owned Autos (Per Accident) Property Damage (Per Accident) EXCESS/UMBRELLA LIABILITY Each Occurrence Occur Claims Made Aggregate Deductible A Workers Compensation and Employers' Liability WC 71949 01/01/2015 01/01/2016 X I WC Statu. tory Limits OTH- ER E.L. Each Accident $1,OD0,000 Any proprietor/partner/executive off"dinember excluded? NO E.L. Disease - Ea Employee $1.000.000 If Yes, describe under Special provisions below. E.L. Disease - Policy Limits 51,000.000 Mar Lion Insurance Company is A.M. Best Company rated A- Excellent). AMB # 12616 Descriptions of Operations/LocationsNehicles/Exclusions added by Endorsement/Special Provisions: Client ID: 91-67-745 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "tient Company": Blue Panther Roofing & Construction Corp Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s,', while working in: FL. Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. Project Name: ISSUE 03-24-15 (EP) CERTIFICATE HOLDER CANCELLATION in Date 1123/2025 MIAMI SHORES VILLAGE BUILDING DEPT, 10050 NE 2ND AVE. Should any of the above described policies be cancelled before the expiration date thereof, the issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any kind upon the Insurer, its agents or representatives. MIAMI SHORES, FL 33138 Rnn? BrAn /CF1 Stern SlnneN Rnnf d SECTION B (Roof Plan) oof Plan: Illustrate all levels and sections, roof drains, scuppers, overfia s and overflow drains. Include dimensions of sections and levels, clearl 11mansinns of alavatari nroamira mnaa and Innatinn of roranats_ r- Florida Building Code Edition 2070 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Stee6 Sloped Roof S stem Roof System Manufacturer: Product Approval Number: Minimum Design Wind Press res, If Applicable (From RAS 127 or Calculations): P1: ''' P2: �'L' �p3: G© Maximum Design Pressure Product Approval Specific System: Method of Tile Attachment: Roof Slope: —0 : 12 Mean Roof Height: /O'P Type & Spacing: Type Cap Sheet: Roof Covering: Type & Size Drips Edge;E�s^ 4�� �m Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M,with the values from Mf. If the M,values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. I Method 1 "Moment Based Tile Ca ulations Per RAS 127" (P,:xA - `--MB: �M„ Product Approval Mf .$ (Pz� x), = -�"'- Mg, r! M �roduct Approval Mf • S (F W x a �- Mg' M�roduct Approval Mf �s' Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf *Must be used In conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P,: x 1: = _x w:= - W: _x cos 0: _= F„ ,_ Product Approval F (PZ: x 1: = _x w:= - W: _x cos 0: F,2 Product Approval F' (P3: _ x 1: - ____x w:= _� - W: -X cos 0: -= Fr3 _ Product Approval F M Requi Moment Resistance* Symbol Where to find Mean Roof Height -► Roof Slope 15' 20' 25' 30' 40- 2:12 34.4 36.5 38.2 39.7 42.2 3:92 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used In conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 127" (P,: x 1: = _x w:= - W: _x cos 0: _= F„ ,_ Product Approval F (PZ: x 1: = _x w:= - W: _x cos 0: F,2 Product Approval F' (P3: _ x 1: - ____x w:= _� - W: -X cos 0: -= Fr3 _ Product Approval F Where to Obtain Information Description Symbol Where to find Design Pressure P1 or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity M• Product Approval Attachment Resistance M, Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance P Product Approval Required Uplift Resistance F, Calculated Average Tile Weighs WProduct Approval Tile Dimensions I m length w m width Product Approval All calculations must be submitted to the Building Official at the time of permit application. SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the c actor. The owner's initial in the designated space indicates that the item has been explained. 1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. .Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 7) 2. 3-Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renal ed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can e ewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water. The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimetededge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7.Ventilation: Most roof structures should have some ability to vent natural airflow through the Vintorof the structure assembly (the building itself). The existing amount of attic ventilation shall not bV reduced. It may be ben cial to consider additional venting which can result in extending the servi rfe of the er Agent's S natu Date Co or Signature Date Revised on 7/9/2009 LD Hanson Roof Tile 1340 SW 34th Ave Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-1210.02 Expiration Date: 12/16/17 Approval Date: 03/21/13 Page 1 of 6 MIAM MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.EOv/pera Hanson Roof Tile 1340 SW 34th Ave Deerfield Beach, FL 33442 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Hanson Hacienda Double Roll Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-1210.02 Expiration Date: 12/16/17 Approval Date: 03/21/13 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Hanson Hacienda Roof Tile, as manufactured by Hanson Roof Tile in Ft. Myers, Florida and as described in Section 2 of this Notice of Acceptance. For the locations where the pressure requirements, do not exceed the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Identifier Test Product Applicant Dimensions Specifications Description Hanson "Hacienda" Length: 17'/4" PA 102(A) Low profile, interlocking, extruded concrete roof Width: 13" TAS 112 tile equipped with two nail hole and double roll 0.63" thick Withdrawal Resistance ribs. For direct deck or battened nail -on, mortar or screw vs. smooth shank nails adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at hips, Letter Dated Aug. 1, 1994 w = varies Aug. 1994 rakes, ridges and valley terminations. 224-47099 varying thickness Sept. 1994 Manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Ft. Myers, FL. 2.2 EVIDENCE SUBMITTED: Test Aizency Test Identifier Test Name/Report Date Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec. 1991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, 1994 PA 108 Aug. 1994 Professional Service Industries, 224-47099 PA 112 Sept. 1994 Inc. The Center for Applied 94-060B PA 101 March, 1994 Engineering, Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-7094-4 PA 102 Oct. 1994 Project No. 307025 PA 100 Oct. 1994 Test #MDC -76 NOA No.: 12-1210.02 h IL"AAM OADe COUNTY Expiration Date: 12/16/17 Approval Date: 03/21/13 Page 2 of 6 2.2 EVIDENCE SUBMITTED: Test Azency Test Identifier Test Name/Report Date 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing 528454-2-1 PA 101 Sep. 1998 Services 520109-2 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 American Test Lab of South RT 1210.01-12 TAS 112 12/14/12 Florida 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No.: 12-1210.02 MAMI•DAD6 COUNTY Expiration Date: 12/16/17 13070711 Approval Date: 03/21/13 Page 3 of 6 4. INSTALLATION 4.1 Hanson `Hacienda' Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (Ibf) Length -I (ft) Width -w (ft) Hanson Hacienda Tile 10.0 1.4375 1.08 Table 2: Aerodynamic Multipliers - X (ft) Tile Profile 1 (ft) % (ft) Batten Application Direct Deck Application Hanson Hacienda Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile Profile 311• 12" 411• 12" 611 • 12" 611• 12" 7"• 12" or greater Hanson Hacienda Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.92 6.80 5.82 6.69 5.70 6.55 5.56 6.39 5.41 6.22 Table 4: Attachment Resistance Expressed as a Moment - Mi (ft-lbf) For Nail -On Systems Tile Profile Fastener Type Direct Deck (Min 16/32" plywood) Direct Deck (Min. 19/32" plywood) Battens Hanson Hacienda Tile 2-10d Rin Shank Nails 27.8 37.4 28.8 1-10d Smooth or Screw Shank Nail 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw 25.8 25.8 22.9. 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails 43.0 67.5 1 50.9 1 Installation with a 4" til; headlap and fasteners are located a min. of 2Y2" from head of tile. NOA No.: 12-1210.02 Expiration Date: 12/16/17 Approval Date: 03/21/13 Page 4 of 6 Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Hanson Hacienda Tile Adhesive 26.1 2 See manufactures component approval for installation requirements. 3 Flexible Products Company TileBond Average weight per patty 11.4 grams. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160. Average weight per patty 8 grams. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Hanson Hacienda Tile 3M 2 -Component Foam Roof Tile Adhesive AH -160 86.61 3M 2 -Component Foam Roof Tile Adhesive AH -160 45.5 4 Large paddy placement of 54 grams 5 Medium paddy placement of 24 grams Table 8: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Attachment Profile Application Resistance Hanson Hacienda Tile Mortar Set 20.6 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo, or following statement: "Miami -Dade County Product Control Approved". Hanson HANSON HACIENDA ROOF TILE (FT. MYERS, FL) TILE IDENTIFICATION MARK (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-1210.02 Expiration Date: 12/16/17 Approval Date: 03/21/13 Page 5 of 6 FASTEI�,r., 7TAi '"Cl PROFILE DRAWINGS BLOCK HANSON HACIENDA CONCRETE ROOF TILE (FT. MYERS, FL) END OF THIS ACCEPTANCE NOA No.: 12-1210.02 Expiration Date: 12/16/17 Approval Date: 03/21/13 Page 6 of 6 MIAMI -RADE � �� � � MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA#12-1219.01 and consists of pages I through 4. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-1113.05 �IgumsxMu4r4�Ioane ml nr Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 1 of 4 ROOFING COMPONENT APPROVAL Cateeory Roofing Sub-Catezory: Underlayment Material: SBS PRODUCTS DESCRIPTION: NOA No.: 13-1113.05 Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 2 of 4 Test Product Product Dimensions Specification Description BORAL TileSeal 36" x 36' rolls TAS 103 SBS self -adhering asphalt sheet material with a 36" x 72' rolls ASTM D 1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. MANUFACTURING LOCATION: 1. Brentwood, NH EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Underwriters Laboratories, Inc. R14610 Follow up Service 03/28/02 IRT-Arcon, Inc. 02-012 TAS 103 02/28/02 PRI Asphalt Technologies, Inc. NEI -006-02-01 TAS 103 04/01/02 PRI Asphalt Technologies, Inc. NEI -008-02-01 TAS 114 (H) 07/30/02 PRI Construction Materials NEI -045-02-01 ASTM D 4798 & ASTM G 155 08/08/07 Technologies, LLC. NEI -053-02-01 ASTM D 4798 & ASTM G 155 05/01/08 NEI -076-02-01 TAS 103 / ASTM D4798 02/14/11 NEI -034-02-02 ASTM D 1970 01/29/13 NOA No.: 13-1113.05 Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type Il or ASTM D 2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 6" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Approved Adhesive Set Roof Tile Systems, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. NOA No.: 13-1113.05 MIAMI -DAD; COUNTY Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below END OF THIS ACCEPTANCE NOA No.: 13-1113.05 M MMADecounmr Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 4 of 4 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.01 MIAMI-DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 1 of 11 I' MIAMI-DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.01 MIAMI-DADE COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using 2 -Component Foam Roof Tile Adhesive AH -160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2 -Component N/A Foam Roof Tile Adhesive AH -160 Foam Dispenser N/A RTF1000 ProPack® 30 & 100 N/A TAS 101 Two component polyurethane foam adhesive PRODUCTS MANUFACTURED BY OTHERS: Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Prove Test Results Density ASTM D 1622 1.6 lbs./ft.' Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft' Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40'F., 2 weeks +6.0% Volume Change @I 58T., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 14-0805.01. MIAMI•DADE COUNTY �FnuuasnglExpiration Date: 05/10/17 l Approval Date: 09/04/14 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Center for Applied Engineering Miles Laboratories Polymers Division Ramtech Laboratories, Inc. Southwest Research Institute Trinity Engineering Celotex Corp. Testing Services Test Identifier Test Name/Repo rt Date #94-060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 NB -589-631 ASTM D 1623 02/01/94 9637-92 ASTM E 108 04/30/93 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 3M'N 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3M"" 2 -Component Foam Roof Tile Adhesive AH - 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 3 of 11 INSTALLATION: 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 maybe used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 14-0805.01 rt AMI-nuoeCOU ry Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile 42 17-19 sq. inches 30 Flat, Low, High Profiles 43 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece j 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. (MIAMIQaoe coi�Wjyjavyjjljn BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-0805.01 MIAMI•DADH COUNTY Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 PW"Y4 x al APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) —23(148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # Z (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 8 of 11 MEN I ADHESIVE PLACEMENT DETAIL # 3 2x4ke. FlatAzwPw1ffaTffa NauthroughpLvacommt Engle paddy twhen reqdvem Battens Shuper A a4 ns 2x4�n. parva , i 0671 2tn. *�' d~3ihFlir4 EaveCmuse Famb Madinat imtiiariie 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x V (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x V (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 int (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) 20 APPROVED -11 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71 cm) square inch adhesive contact with the underside of the the at the overlap and 7 (45.2 cm) - 9 (58.1 cm) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 10 of 11 ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL t) place enough adhesive to achieve 65 to 70 sq.)n. Steep pitch applications In contact with the pan die. /1 (when required) 2) Turn covers upside dawn Place adhesive In to t in.from outside edge of cover We. Then install the die. Ensure 20 to 25 sq.in.contact area. t` IUnderlayment (motar shown) Fascia Remave top portion of the eave course cover die. Abutto second course of pan dies. Ensure eave end of pan and coverdies are flush ateave fine. Tier* Piece Barrel -High Profile Tile MIAMI -DARE COUNTY Two Piece Barrel (Cap and Pan) Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 11 of 11 4 7056 SW 4,C Street Miami, FL 33155 Tel: 786-396-9179 Fax 786-500-2527 al roolinsaedonDgmail.c om LAB CERTIFICATION #10-0512-01 SITE SPECIFIC INFORMATION UPLIFT TEST - TAS #106 Roofing Contractor BLUE PANTHER ROOFING. Job Address 553 NW 113 ST MIAMI SHORES, FL. Owner's Name JOSEPH Type of Tile HANSON HACIENDA Approximate Roof Height 1r feet Roof Pitch 3/12 Approximate Square Footage of Roof 15 ft2 Date Tested 0004/15 Number of Tests 43 Contact Name JUAN HERRERA Permit # RF -3-15-654 Date installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 71255-6661 LOCATION #-OF TEST PASS # OF TEST FAIL Corner 6 Tests .6 ,_ Pass Test 0 Fail Perimeter 11 Tests 11 Pass Test 0 Fail Field 20 Tests 20 Pass Test 0 Fall Ridge 6 Tests 6 Pass Test 0 Fail TOTAL 43 Tests 43 Pass Test 0 Fail IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL PA 206, THIS ROOF ASSEMBLY HAS PASSEDTHE STATIC UPLIFT QUALITY CONTROL TEST. THISTAS 106 TEST HAS BEEN PERFORMED IN FULLACODRDANCE TOTHE REQUIREMENTS OF DADS COUNTRY, WITH NO DEVIATIONS. THIS REPORT IS NOT GUARANTEED IN CASE OF CASE OF NATURAL DISASTERS. THIS REPORT ITIS NOT VALIO FOR INSURANCE aAIMs. A-1 Engineering Inspection Services, Inc 7066 SW 44th Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 alroofiMection gamail.com LAB CERTIFICATION # 14-1215.04 04/04/15 PERMIT. # RF -3-15-654 553 NW 113 ST MIAMI SHORES, FL. 7066 SW 44a Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627