Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
CC-15-39
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-231535 Permit Number: CC -1-15-39 Scheduled Inspection Date: April 06, 2015 Permit Type: Commercial Construction Inspector: Rodriguez, Jorge Inspection Type: Final Building Owner: , BARRY UNIVERSITY Work Classification: Alteration Job Address:11300 NE 2 Avenue Health & Sports Miami Shores, FL 33138-0000 Phone Number Parcel Number 1121360010160-23 Project: BARRY UNIVERSITY Contractor: SOUTHEASTERN SURFACES & EQUIPMENT Phone: (386)428-8875 kJu comments INSTALL STADIUM SEATING AT SOFTBALL AND " "" 1-42Otl" BASEBALL FIELDS. INSPECTOR COMMENTS False Passed Inspector Comments Failed Correction Needed ❑ Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. April 06, 2015 For Inspections please call: (305)762-4949 Page 26 of 40 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑PLUMBING ❑MECHANICAL ❑PUBLICWORKS FBC 20 10 Master Permit No. Sub Permit ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOBADDRESS: 11300 NE 2ND Avenue, Miami Shores, FL 33161 Softball/Baseball Fields H'? Citv: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Barry University Phone#: 305-899-4910 Address: 11300 NE 2ND Avenue City. Miami Shores State: FL Zip; 33161 Tenant/Lessee Name: N/A Email: CONTRACTOR: Company Name: Southeastern Surfaces & Equipment Phone#: 386-428-8875 qVy-Q:;2,':�jgq Address: 1331 99TH Street City. Bay Harbor Island State: FLZip; 33154 Qualifier Name: Ralph Olesky Phone#: 386-428-8875 State Certification or Registration #. CGC012423 Certificate of Competency #: DESIGNER: Architect/Engineer: N/A Phone#: Address: City: State: Zip: Value of Work for this Permit: $11,695.00 Squire/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New 0 Repair/Replace Description of Work: Install stadium seating at softball/baseball fields. ❑ Demolition Specify color of color thru tile: L C� Submittal Fee $ 31(1 Permit Fee $ w ' �J CCF $ CO/CC $ Scanning Fee $ Technology Fee Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City N/A State Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. TI x'11<<Signature OWNER or AGENT The f �regoing instrument was acknowledged before me this I^ " day of b hgU4 20 by SLI 1W4 ft5t-N'rNAU who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: MY Corm MW FF 188461 EXOU I IIIZ2018 as CONTRACTOR The foregoing instrument was acknowledged before a this day of � cue "4 ✓ .20 by rC I1AW1 e,.1 -,A -t T k \ LQ who is per§orlally known to T-crG- Ares 3 I me or who has produced as identification and who did take an oath. �1,111" kic, So"�'%O S�c-,-kctS APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) OLESKY, ar tsv�[�r��.xc�aul�tcr►vnt FWC'.T'I¢ I t"iU `t Y L� Nii� +lea �C»i AIICOR To CCO CERTIFICATE OF LIABILITY INSURANCE DATE (MM/DDNYYY) 1/5/2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Bowen, Miclette & Britt of Florida LLC 1020 N. Orlando Avenue Suite 200 Maitland FL 32751 NcAOMEAc`r Emily Howell PHONe 407 647-1616 FAX No,, : 4O7 628 1635 E-MAIL . certificates@bmbinc.com INSURER(S) AFFORDING COVERAGE NAIC @ COMMERCIAL GENERAL LIABILITY INSURERA:Amerisure Insurance Company 19488 Y INSURED SSEASSOCIA2 INSURERB:Amerisure Mutual Insurance Company 23396 SSE & Associates Inc. dba Southeastern Surfaces & Equipment; SSE & Assoc., Inc. dba SSE Modemfold P.O. Box 602 INSURER C: INSURER D INSURER E: New Smyrna Beach FL 32170 INSURER F: COVERAGES CERTIFICATE NIIMRFR• 296179328 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR LTR TYPE OF INSURANCE INSD WVD POUCYNUMBER POLICY EFF MM/DD POLICY EXP MM/DD LIMITS A X COMMERCIAL GENERAL LIABILITY Y Y GL2084675 /17/2014 /17/2015 EACH OCCURRENCE $1,000,000 CLAIMS -MADE X❑ OCCUR PREMISES EaEoccurrence) $100,000 MED EXP (Any one person) $5,000 PERSONAL BADV INJURY $1,000,000 AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $2,000,000 GEN'L POLICY a JECOT- El LOC PRODUCTS - COMP/OP AGG $2,000,000 $ OTHER: B AUTOMOBILE LIABILITY Y Y CA2084673 /17/2014 /17!2015 COMBINED SINGLE LIMIT Ea accident$1,000,000 BODILY INJURY (Per person) $ AUTO gg AUTOSNED ALITOSULEDBODILY INJURY (Per accident) $ IxANY HIRED AUTOS X NON -OWNED AUTOS PROPERTYDAMAGE $ Per acddent B X UMBRELLA LIAB X OCCUR Y Y CU2084679 /17/2014 /17/2015 EACH OCCURRENCE $5,000,000 AGGREGATE $5,000,000 EXCESS LIAB CLAIMS -MADE DED I X I RETENTION $0 $ B WORKERS COMPENSATION AND EMPLOYERS' LIABILITY YIN ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? N] (Mandatory in NH) N /A y WC2086530 /17/2014 /17/2015 PER X ER E.L. EACH ACCIDENT $1,000,000 E . DISEASE - EA EMPLOYEE $1,000,000 If yes, describe under DESCRIPTION OF OPERATIONS below E.L. DISEASE - POLICY LIMIT 1 $1,000,000 DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached H more space Is required) The following policy provisions and/or endorsements form part of the policies of insurance represented by this certificate of insurance. The terms contained in the policies and/or endorsements supersede the representations made herein. Electronic copies of the policy provisions and/or endorsements listed below are available by emailing: certificates@bmbinc.com When required by written contract, those Parties listed in said contract, including the certificate holder, are added as an Additional Insured, with respect to General Liability, including products and completed operations, Auto Liability, and Umbrella liability as afforded by the policy See Attached... CERTIFICATE HOLOFR CANCELLATION ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25 (2014101) The ACORD name and logo are registered marks of ACORD SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Miami Shores Village Building Department ACCORDANCE WITH THE POLICY PROVISIONS. 10050 NE 2nd Avenue Miami Shores FL 33,138 AUTHORIZED REPRESENTATIVE ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25 (2014101) The ACORD name and logo are registered marks of ACORD ASC` AGENCY CUSTOMER ID: SSEASSOCIA2 LOC #: ADDITIONAL REMARKS SCHEDULE Page 1 of 1 AGENCY NAMED INSURED Bowen, Miclette & Britt of Florida LLC SSE & Associates Inc. dba Southeastern Surfaces & Equipment; SSE & Assoc., Inc. dba SSE Modemfold P.O. Box 602 POUCY NUMBER New Smyrna Beach FL 32170 CARRIER NAIC CODE EFFECTIVE DATE: ADDITIONAL REMARKS THIS ADDITIONAL REMARKS FORM IS A SCHEDULE TO ACORD FORM, FORM NUMBER: 25 FORM TITLE: CERTIFICATE OF LIABILITY INSURANCE and/or endorsements. The General Liability and Auto Liability policy certified herein is primary and non-contributory to other insurance available to the certificate holder, but only to the extent required by written contract with the Named Insured. When required by written contract, waiver of subrogation, with respect to General Liability, Auto Liability, Workers Compensation, and Umbrella is granted in favor of Certificate Holder as afforded by the policy and/or endorsements. SSE & Associates GC License #CGC012423 ACORD 101 (2008/01) © 2008 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD 00436 JAN 0 IS Zu !'F— I 12 22 USERALL FI 1 2 4 5 6 7 8 9 10 22' -4" 11 12 NOTE: I It 5 THE RESPOSDIM OF THE OM AND ARDMtT TO PROVIDE SEATM AND ACCESSIBLE PATHS Of TRAVEL THAT CONFORM TO THE REGUMM OF THE AKERJEM WITH DISAMRS ACT TITLE M TO ACCOMMODATE OlD=WS WITH BOSOMS THE OWNER AND ARCH- 1119 ARE RMIM TO COMSAT THE FEDERAL STATUTE CFR PART 36 FOR RERILATOWMADMIGTOACCEM SEATMFOR AHEREUIS WITH DSABURS. QUATMO LEGEND § W - T/A RRADY AM - TI TAIM AM 42 7ABLSP OX ADA STANCHION 01 - Am Lmff = M PANELS FROM CURROLM EmAm CHAD! 6522 11'-4" 2! TMEMMUR SPAM -VILEASE NOTE- SOMALL. FIELD - IST BASE SID jja ,66022 11'-4" IWO �0= La L1 OME SM, Sawr SALL ZW SHOW WY NOT PERTAIN TO Pos XB NOTE: :AMKMFM ON THIS :9ORSEATING my SOFTBALL FIELD - 3RD BASE SIDE SEATING LAYOUT E ;7uj "i EL IL 0 z < N Co co n c LL - m 14 HEX NUT CHAER SI J 1/4* SPUT LOCK WASHER r4 I V DmD r -r (519] 3/4* ANCHOR WASHER UECKANICALWRANCHOR 1/4 3 1/4 ANOMOR 12) 6D ISTV --r ML41 TI CALL ROCK M, AID RM (MUSCITO OF (OWETE OUT .. MIR TO .. ". , M-CUTORPOURIDINUSTIDEITHEFOLLOM OF ANCHOR g 11/ 4-1 aFLOORMAB POT BE V 11421710 *WITH THE TOP TO 7511ELEAROFANT MSTRUCTIORSMAII.RMEM WA 1.= .w bdm=asYAuanox ft — 2. �,?4"*DIA DRILL 2WRAIALONOTHEFACECLEARDWYOUTIHICTIM 4 FLOOR MOUNT FLOOR MOUNT ANCHOR DETAIL (MOUNTNG TO EXISTING CONCRETE SLAB) tAll. ODWTEKUST HAVE AMDOWSIREIMTH OF 3,00 NU FOR Oft WEKHT AM64TE AHD 5.00 PSI FOR LUDOWEIGUIAMURINDIMORTO 0 TAM PON d.AU. STIELROORMISERS MUSTOE V4'161MNTD WID)WIM&MA36STED. SSE POW EXISTING CONCRETE SLAB— I ALL ROORS CONSTRUCTED IF WOOD MUST Asme 1 ALL ROW LOM DMITO ON 711 MAN OF SEATM IRULDE END SPAIN AS STATED ON THIS DRAWW. OPTION 4 PROPOSAL H=y Or No. F7.-K—� 4. RUB TO III WSTAUATM / KMNAUE MAIM FORASSENRLYDISTRUCTM. spol (s .. * I SECTION 12630 - STADIUM AND ARENA SEATING PART 1 -GENERAL 1.01 SUMMARY A. Section Includes: Fixed plastic chairs with self -rising seat mechanisms, aisle and intermediate stanchions. 1. Typical applications include the following: a. Floor mounted chairs. B. Alternates: This section specifies alternates for seating products. Refer to Part 2 products for alternate products and to Division 1 Alternate sections and other bid documents, if any, for alternate requirements. C. Product Improvements: Hussey Seating Company strives to continuously improve its products and manufacturing methods. The company reserves the right to make changes without notice when, in the opinion of the company, such changes improve the product or its performance. 1.02 REFERENCES A. National Fire Protection Association (NFPA) 1. NFPA 102 Standard for Assembly Seating, Tents and Membrane Structures. B. American Institute of Steel Construction (AISC): 1. AISC - Design of Hot Rolled Steel Structural Members. C. American National Standards Institute (ANSI). D. American Iron & Steel Institute (AISI): 1. AISI - Design Cold Formed Steel Structural Members. E. American Society for Testing Materials (ASTM) 1. ASTM - Standard Specification for Properties of Materials. F. Americans with Disability Act (ADA) 1. ADA - Standards for Accessible Design. 1.03 MANUFACTURER'S SYSTEM ENGINEERING DESCRIPTION A. Structural Performance: Engineer, fabricate, and install stadium and arena seating to the following structural loads without exceeding allowable design working stresses of materials involved, including anchors and connection. Apply each load to produce maximum stress in each respective component of the seating unit. B. Manufacturer's System Design Criteria: 1. Seats and Backs: a. Shall embody a contemporary sculptured appearance to harmonize with any architectural form or room decor. 12630-1 HUSSEY SEATING COMPANY Fusion—Specification STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B b. Shall exhibit moderate compound contours for supportive comfort avoiding excess anatomical pressures. c. Seat shall be semi -cantilevered, self -rising, for ease of passage and janitorial access. d. Seat shall be tested and professionally certified through an independent testing laboratory to support and withstand an evenly distributed 600 Ib. [272.1 Kg] static load without failure or irregularities that would impair usefulness. e. Self lifting seat shall be tested and professionally certified through an independent testing laboratory to withstand 350,000 operating cycles without added lubrication, spring fatigue, adjustment, or measurable bearing wear. f. Seat shall be tested and professionally certified to withstand, without failure, 10,000 impacts, of a 40 Ib. [18.14Kg] sandbag dropped on the center of seat from each of the following heights of 6 inches [152mm], 8 inches [203mm], 10 inches [254mm], 12 inches [305mm] at a rate of 18 impacts per minute for a total of 40,000 impacts. g. Back shall be tested and professionally certified through an independent testing laboratory to withstand an evenly distributed front or rear static load of 450 lb. [204.08Kg]. h. Back shall be tested and professionally certified to withstand, without failure, 40,000 swinging impacts each to the front and rear of the back by means of two opposing 40 lb. [18.14Kg] sandbags. The sandbags shall be moved horizontally and equally for 10,000 cycles each at the following distances of 6 inches [152mm], 8 inches [203mm], 10 inches [254mm], and 12 inches [305mm] at a rate of 18 cycles per minute. i. Horizontal Traverse Static Load to Back: Backs shall withstand an evenly distributed static load of 200 lbs [90.701(g] to the top of the back at a 45 degree angle to the row of seats. j. Armrests shall be tested and professionally certified to withstand an evenly distributed static load of 200 lbs [90.70Kg] applied perpendicular to the armrest. 2. Material (Flammability) shall satisfy applicable test, codes, standards, or requirements as follows: a. Polyethylene shall meet the Federal Motor Vehicle Safety Standard No. 302 which specifies a burning rate of less than 4 inches per minute. 1.04 SUBMITTALS A. Section Cross -Reference: Submit required submittals in accordance with "Conditions of the Contract" and Division 1. General Requirements sections of this "Project Manual." B. Project Data: Manufacturer's product data for each system. Include the following: 1. Project list: Ten (10) seating projects of similar size, complexity and in service for at least five (5) years. 2. Deviations: List of deviations from these project specifications. 12630-2 HUSSEY SEATING COMPANY Fusion—Specification STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B C. Shop Drawings: Indicate plastic chair seating layout. Show all equipment to be furnished with details of accessories to be supplied. D. Samples: Seat materials and color finish as selected by Architect from manufacturers standard color finishes. E. Manufacturer Qualifications: Certification of insurance coverage and manufacturing experience of manufacturer F. Installer Qualifications: Installer qualifications indicating capability, experience, and manufacturer acceptance. G. Engineer Qualifications: Certification by a professional engineer registered in the state of manufacturer that the equipment to be supplied meets or exceeds the design criteria of this specification. H. Operating/Maintenance Manuals: Provide to Owner maintenance manuals. Demonstrate operating procedures. I. Warranty: Manufacturers standard warranty documents. 1.05 QUALITY ASSURANCE J. NFPA Standard: Comply with current NFPA 102 Standard for Assembly Seating, Tents and Membrane Structures, except where additional requirements are indicated or imposed by authorities having jurisdiction. K. Insurance Qualifications: Mandatory that each bidder submit with his bid an insurance certification from the manufacture evidencing the following insurance coverage: 1. Workers Compensation - including Employers Liability with the following limits: a. $500,000.00 Each Accident b. $500,000.00 Disease - Policy Limit c. $500,000.00 Disease - Each Employee 2. Commercial General Liability - including premises/ operations, independent contractors and products completed operations liability. Limits of liability shall not be less than $2,000,000.00 L. Manufacturer Qualifications: Manufacturer who has ten (10) years of experience manufacturing spectator seating equipment. M. Installer Qualifications: Engage experienced Installer who has specialized in installation of audience seating similar to types required for this project and who is acceptable to, or certified by, spectator seating manufacturer. N. Engineer Qualifications: Engage a professional licensed engineer experienced in providing engineering services of the kind indicated that have resulted in the successful installation of audience seating similar in material, design, fabrication, and extent to those types indicated for this project. 1.06 DELIVERY, STORAGE AND HANDLING 12630-3 HUSSEY SEATING COMPANY Fusion—Specification STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B A. Deliver seating in manufacturers packaging clearly labeled with manufacturer name and content. B. Handle seating equipment in a manner to prevent damage. C. Deliver the seating at a scheduled time for installation that will not interfere with other trades operating in the building. 1.07 PROJECT CONDITIONS A. Field Measurements: Coordinate actual dimensions of construction affecting audience seating installation by accurate field measurements before fabrication. Show recorded measurements on final shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid delay of Work. 1.08 WARRANTY A. Manufacturer's Product Warranty: Submit manufacturer's standard warranty form for fixed chairs. This warranty is in addition to, and not a limitation of other rights Owner may have under Contract Documents. 1. Warranty Period: Limited Lifetime 2. Beneficiary: Issue warranty in legal name of project Owner. 3. Warranty Acceptance: Owner is sole authority who will determine acceptance of warranty documents. 1.09 MAINTENANCE AND OPERATION A. Instructions: Both operation and maintenance shall be transmitted to the Owner by the manufacturer of the seating or his representative. B. Service: Maintenance and operation of the seating system shall be the responsibility of the Owner or his duly authorized representative, and shall include the following: 1. Only attachments specifically approved by the manufacturer for the specific installation shall be attached to the seating. 2. An annual inspection and required maintenance of each seating system shall be performed to assure safe conditions. At least biannually an inspection shall be performed by a professional engineer or factory qualified service personnel. PART 2 -PRODUCTS 2.01 MANUFACTURERS A. Manufacturer: Hussey Seating Company, U.S.A. 1. Address: North Berwick, Maine, 03906 2. Telephone: 800 341-0401; Fax: (207) 676-9690 3. Email: info@hussyseating.com 12630-4 HUSSEY SEATING COMPANY Fusion_Specification STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B 4. Product: Hussey Fixed Plastic Chairs. a. Model: Fusion b. Available Chair Sizes: 22" c. Back Type: Plastic d. Seat Type: Plastic e. Stanchions: Riser mount 5. Product Description/Criteria: a. Number of Chairs:_24 b. Number of Rows:_3 c. Number of Wheelchair Locations: 6 d. Number of ADA End Stanchions: n/a e. Row Spacing: n/a f. Rise: n/q 6. Product Accessories: Seat numbers, Row letters, Donor plates 2.03 MATERIALS A. Cast Aluminum: Aluminum Alloy AA 380 B. Cast Iron: ASTM A48 and ASTM A536 C. Drilled -in Expansion Anchors: SAE grade 2 D. Blow molded plastic: Virgin high density polyethylene with a melt index of 0.40 per ASTM D1238. 2.04 FABRICATION A. (Outdoor) Plastic backs shall have a smooth surface for easy cleaning, and be constructed of double wall blow molded polyethylene with anti -static compound and ultra -violet light stabilizing additives. Backs shall have a nominal wall thickness of 0.125 inch [3mm] and be ergonomically contoured for posture and sitting comfort. B. (Outdoor) Plastic seats shall have a smooth surface for easy cleaning, and be constructed of double wall blow molded polyethylene plastic with anti -static compounds and ultra -violet light stabilizing additives. Seats shall have a nominal wall thickness of 0.125 inch [3mm] and be ergonomically contoured for posture and sitting comfort. C. Back height to be 32 inches [813mm] from floor and extend below the seat to afford chair occupant protection from rear and eliminate any pinching hazard. Back length shall be 21 inches [533mm] nominal. D. Stanchion back pitch shall be 15 degrees. E. Backs shall be though bolted to stanchions at four (4) connection points. Bolt heads shall be recessed below the surface of the back. F. Backs shall be recessed to receive an adhesive backed number label with silk screed black numbers. Label fitted in vandal resistant recess. 12630-5 HUSSEY SEATING COMPANY Fusion—Specification STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B G. Backs shall be recessed to receive an aluminum number plate. Label fitted in vandal resistant recess and secured with two (2) aluminum pop rivets. H. Seats shall be securely fastened to cast iron hinge arms by means of four fastening screws into threaded metal inserts molded in the underside of the plastic seat. No exposed fasteners shall be located on the seat surface. 1. Seat Hinge Arms. 1. Seat hinge arms shall be recessed under each side of the seat and provide support for the plastic seat. 2. Hinge arm shall be made of cast iron and its shape shall follow the contour of the seat. 3. Hinge arms shall be finished to match stanchion color. J. Seat Hinge Mechanism. 1. Seat hinge mechanism shall consist of two independent dual function torsion springs designed to automatically return the seat to a 3/ upright position. Hinge design shall include a feature to allow for manual rotation of the seat from the 3/ upright position to a full vertical upright (safety fold) position. The hinge mechanism shall automatically return the seat from the safety fold to the 3/ upright position. 2. Seat hinges shall utilize permanently lubricated oil impregnated bearings. Springs, pivot shafts, and rotational stops shall be concealed within the hinge arm to eliminate pinch points and protect the components from dirt and weather. K. Cast Aluminum Stanchions: 1. Stanchions shall be die cast from Aluminum Alloy 380 for a rust free finish with armrests cast as an integral feature of the stanchion. 2. Stanchions shall have open panel design with optional clamp -on filler panel with logo. 3. Stanchions shall be floor attached, designed to maintain a constant seat height to floor. L. Finish: 1. Cast Aluminum Finish (Stanchions): Cast Aluminum shall be chemically cleaned, treated with a protective sealing primer, then coated with an architectural grade exterior polyester powder coat with a dry film thickness of 2 - 3 mils. The performance of the powder will pass the 2H Pencil Hardness test (ASTM D3363) and 1500 hours of Salt Spray (ASTM 131 17a). 2. (Outdoor) Plastic: Shall be blow molded polyethylene plastic with ultra -violet light stabilizing additives pigmented in one of the manufacturer's twenty-two standard colors. 3. Color: Shall be per manufacturer's standards. Seating Contractor shall submit color samples for owner's approval prior to manufacture. 2.05 FASTENINGS A. Chair Assembly 1. All structural connections shall be made with stainless steel bolts, washers and nuts. Bolts shall be applied with a nylon patch lock to prevent loosening. 12630-6 HUSSEY SEATING COMPANY Fusion—Specification STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B . .. B. Concrete Floor Attachment 1. Chair stanchions shall each be attached by means of two 1/4"[6mm] mechanical wedge anchors set in holes drilled to a minimum depth of 2"[50mm] in the concrete. a. Wedge anchors shall be tested to ASTM E488 criteria and listed by ICBO and SBCCI. Wedge anchors feature a type 18-8 stainless steel split expansion ring and a threaded stud bolt body and integral cone expander. Stanchion shall be placed on the bolts and permanently secured with a flat washer, lock washer and nut. 2.06 ACCESSORIES A. Seat Number Plates: Chair numbers shall be black numerals etched on an elliptical aluminum plate. Number plates to be located in vandal resistant recess in the upper left hand corner of the back and secured using two (2) aluminum pop rivets. B. Row Letter Plates: Row letters shall be a black letter etched on an elliptical aluminum plate. Letter plates shall be surface mounted to the aisle end stanchion and secured using two (2) aluminum pop rivets. PART 3 - EXECUTION 3.01 EXAMINATION A. Verification of Conditions: Verify area to receive audience seating are free of impediments interfering with installation and condition of installation substrates are acceptable to receive audience seats in accordance with seating manufacturer's recommendations. Do not commence installation until conditions are satisfactory. 3.02 INSTALLATION A. Manufacturer's Recommendations: Comply with seating manufacturer's recommendations for product installation requirements. B. General: Install fixed audience seating in accordance with manufacturer's installation instructions and final shop drawings. Provide accessories, anchors, and assembly hardware for installation of seating and for permanent attachment to adjoining construction. 3.03 ADJUSTMENT AND CLEANING A. Adjustment: After installation completion, all equipment is to be adjusted for smooth and proper operation. B. Cleaning: Clean work area and remove debris from site. HUSSEY SEATING COMPANY Fusion_Specification 12630-7 STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B 4 n 3.04 PROTECTION A. General: Provide final protection and maintain conditions, in a manner acceptable to manufacturer and installer to ensure audience seats are without damage or deterioration at time of substantial completion. B. Finish Touch-up: Tough -up original manufacturer's finish coating with an approved touch-up paint whenever damage has occurred during shipment or installation. Color to match the original manufacturer's color. HUSSEY SEATING COMPANY Fusion—Specification END OF SECTION 12630-8 STADIUM AND ARENA SEATING REV. DATE: October 12 Rev B