RC13-2871Miami Shores Village
q ( g
Building Department artment DEC 2 7
�U 10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972 '
a l l INSPECTION'S PHONE NUMBER: (305) 762.4949
1231 �i3�mA-CA-0 FBC20
BUILDING Permit No.
PERMIT APPLICATION Master Permit No.hC �3 — r:2S-7/
Permit Type: BUILDING
ROOFING
JOB ADDRESS: 3 `at O N C 0\ S� .
City: Miami Shores County: C
Folio/Parcel#: - -F N _0 0 1 -3 IR 0 q 7-4 3
Is the Building Historically Designated: Yes
OWNER: Name (Fee Simple Titleholder): LI rl(R
Address: 3pi J � V t Cl �) SA
City: State:
Tenant/Lessee Name:
Email:
NO
1 o V4 — 61 (A
— N --- 7 1
_Flood Zone:
�1�() z' �o s 521+
4 1 /16
hone#:
ZO� � %
CONTRACTOR: Company Name; S LPA Go NS'�'iR-il C-J�' 1011 l tgCPhone#: .� '0 5 � V 5q'l r
O 3 J
Address: k'8 \ S \�( k 38 CSG
City: MX X11 State: �'' Zip: 33 t8G
Qualifier Name: E la -k C- S ��—}� � Phone#: 3OS " 4t -z_(3 S�
State Certification or Registration #: C_ C. So"1•�1 "Z Certificate of Comp ten #:
Contact Phone#: Email Address: S qCA ���0 • Yie,
DESIGNER: Architect/Engineer: Phone#:
Value of Work for this Permit:
Type of Work: ❑Addition
Description.of Work:�'�-
r Square/Linear Footage of Work:. '
Alteration ❑New ❑Re air/Replace ❑Demolition
Color thru tile:
Submittal Fee $Ji ,J` 0, 00 Permit Fee $ CCF $ CO/CC $
Scanning Fee $
Notary $
Double Fee $
Radon Fee $
Training/Education Fee $
tructural Review $
DBPR $ Bond $
Technology Fee $
TOTAL FEE NOW DUE
-L
ELCTRICAL NOTES
1- ALL ELPCTRICAL WORK SHALL BE IN ACCORDANCE WITH THE
NATIOrIAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
2- ELECTPICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM-
PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL
ENERGY EFFICIENCY CODES.
CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR
HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS.
3- ALL ELI=CTRICAL WORK SHALL BE PERFORMED BY A LICENSED
ELECTI"ICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO
SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION,
AS REQUIRED.
4- SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE
MADE V�JITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A
SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR
SUCH (,HANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI-
NEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER.
5- UP SUC%H TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE
COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED
CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION,
UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR
ABUTTING WORK TO BE PERFORMED BY OTHERS.
6- ALL CCINDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE SIZE
SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE
GROUI'ID CONDUCTOR PER NEC 250-122.
7- CIRCUIT NUMBERS SHOWN ARE FOR CALCULATIONPURPOSES ONLY.
ACTUAL CIRCUITING MAY VARY ACCORDING TO NEC AND FBC
PROVVE PANEL SCHRDULE AFTER COMPLETION.
8- EXTERIOR DISCONECT SUBJECT TO RAIN MUST BE N -3R UL.
9- GROUI,IDING TO INCLUDE LOW VOLT SYSTEM BONDING NEC 250.94
10- THE LIGHTING COMPLIES WITH THE FBC E 404.1.
LOAD COMPUTATION PANEL (A)
GENERAL LIGHTING
2,379 SQ. FT. @ 3W/SQ. FT.
WATTS
CKT
SMALL APPLIANCE CIRCUITS:
3 CIRCUITS x 1500
FIXED APPLIANCES:
8
#12 / 1/2"C GENERAL LIGHT./RECEP
RANGE 12,000
DRYER 5,000
WASHER 1,500
REFRIGERATOR 1,500
DISHWASHER 1,000
WATER HEATER 5,500
MICI11OWAVE 1,500
GARBAGE DISPOSER 600
ALARM 800
EX-fERIOR WP/GFI 720
WHIRLPOOL (FUTURE) 2000
WINE COOLER 1500
RANGE HOOD EXHAUST FAN 600
GARAGE DOOR OPENER 800
POOL EQUIPMENT (FUTURE) 2,800
POOL HEATER (FUTURE) 7,000
20
CONNECTED LOAD LESS A/C = 56,457 W
720
10,00ow c 100% = 10,000
REST W @ 40% = 46,457 18,583
A/C (OR HEATING) @ 65% = 10,200
DEMAND LOAD: 38,783 /240 WATTS = 161.60 AMPS
240/120
PANEL SIZE = 200 AMPS
NOTES: A/C @ 100% = 10,200
HEAT @ 65% = 6,630
ELECTRICAL RISER
EXISTING 120/240 V,
3 WIRE, 1 -PHASE # 3/0
THWN, Cu IN 2" RIGID
CONDUIT
LEGEND
[]� FUSE OR DISCONNECT SWITCH
Simon ELECTRIC PANEL
MD ELECTRIC METER
SCOPE OF WORK:
1- REMOVE ELECTRICAL PANEL
2- NEW ELECTRICAL PANEL (PEE LOCATED)
O.H. ELECTRIC SERVICE
FROM FPL
TRANSFORMER
(NTS)
EXISTING 3 # 3/0 & 1 44
THWN (CU.) IN 2" COND.
NEW 3 #3/0 THWN ((AJ ` IN
2" COND.
PANEL A
EXISTING NEk,V 200 AMP.
2XI AMP ELECTRICAL
ELECTRICAL PAldl_:L BOARD
METER0 WATERPROOF
Afrr=RPROOF
GROUNDING TO INCLUDE LOW VOLT SYSTEM
RnNnING IFC 250.94
■■
EXISTING 200 AMP DISC. BIRK'R
WATER PROOF
EXISTING 1 #4 CU IN 1/2" G'__yND.
TO 1/2" COLD WATER PIPE
EXISTING 1 #4 CU (GN'D. PER N.E.0
CWP
(METAL)
GRADE��
1-5/8" COPPERCLAD GROUND ROD '10
FT. LONG
BUILDING STEEL FOIJNDA'I :ON
CONCRETE -ENCASED ELECTRODE: AN ELECTRODE ENCASED BY AT LEAST 2 INCHES (50.8 mm) OF
CONCRETE, LOCATED WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTIW:1
THAT IS IN DIRECT CONTACT WITH THE EARTH, CONSISTING OF AT LEAST 20 FEET (6.1 m) OF ONE (ifs
MORE STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH (12.7 mm) DIAMETER, OR
CONSISTING OF AT LEAST 20 FEET (6.1 mm) OF BARE COPPER CONDUCTOR NOT SMALLER THAN No. 4
AWG.
I
TYPE: SQUARE "D" OR EQUIVALENT APPROVED
VOLTAGE: 240/120V /\ � j � � : /�
A
VOLTAGE: 200A PJA
MOUNTING: SURFACE / WATER PROOF —
AMPS
POLES TOTAL
VA
WIRE/ DESCRIPTION
CONDUIT
CKT
20
1
8
#12 / 1/2"C GENERAL LIGHT./RECEP
1
20
1
REFRIGERATOR
#12 / 1/2"C GENERAL LIGHT./RECEP
3
20
1
18
#12 / 1/2"C GENERAL LIGHT./RECEP
5
20
1
WASHER
#12 / 1/2"C GENERAL LIGHT./RECEP
7
20
1
720
#12 / 1/2"C EXT. WP/GFI & RECEPT.
9
20
I
1500
#12 / 1/2"C WINE
11
20
1
1500
#12 / 1/2"C SMALL APPL
13
20
1
1500
#12 / 1/2"C SMALL APPL
15
20
1
1500
#12 / 1/2"C SMALL APPL
17
20
1
1500
#12 / 1/2"C MICROWAVE
19
20
1
k
#12 / 1/2"C GENERAL LIGHT./RECEP
21
20
1
'1500
1#12 / 1/2"C DISHWASHER
23
40
2
5500
8 / 3/4"C WATER HEATER
25
20
2
2800
#12 / 1/2"C POOL PUMP (FUTURE)
27
29
1 40 1 2 1 2800 W8 / 3/4"C (POOL HEE
1 20 1 2 12000 P12 / 1/2"C IWHIRPOC
20 I1 1#12 / 1/2"C ISPARE
20 1k #12 / 1/2"C ISPARF
DEMAND LOAD: 38,783 W = 161.60 AMPS.
(SEE LOAD CALCULATION)
CKT. (DESCRIPTION
2
DRYER
4
20
6
GENERAL LIGHT.
8
GENERAL LIGHT.
10
BATH LGTS.
12
REFRIGERATOR
14
A/C AHU
16
18
_
KIT./BATH LGTS.
20
RECEPTACLES
22
WASHER
24
GENERAL LIGHT.
26
RANGE
28
cl)
30
CONDENSING UNIT
MAIN BUS: 200 AMP.
NEUTRAL: 200 AMP.
MAINS: 200 AMP
LOCATION: EXTERIOR
VIRE: / OTAL POLES AMPS
;ONDUIT VA
'101 1 /2"C 5000 1 2 1 30
10 2 / 1/2"C 1 20
#12 / 1/2"C
1
20
f114 / 1/2"C
1
20
#12 / 1/2"C 1500
1
20
#6 / 3/4"C 10200
2
60
X14 /,1/2"C * 1 20
:14/1/2"C *
1
20
12/1/2"C 1500
1
20
L'14/1/2"C
1
20
#6l3/4"C 12000
2
50
/ 3/4"C 16200 1 2 1 50
EXISTING OVERHEAD ELECTRICAL
SERVICES FEEDER TO POWER
JAN 2 120'14
NORTH EXISTING FLOOR PLAN TO REMAIN
SCALE: ,,a -, O
r
Ni
W
a
W
OL
n
O
J
Z
F
Ww
V3
W
F—
J
J
of
cl)
OU
3
o—
Wp
0a
8
JOB No. 14003
STARTED: 01/08/14
DATE PRINTED: 01/10/14
REVISION
No. I DESCRIPTION I DATE:
W
\
J
Z
z
a
cl)
o—
w
W
a
I
(1)U
0Cc�
�
IL�—a�=
�
U
cc
CLJa
W
U
z
zZ
-I
�
F—
a
�
JOB No. 14003
STARTED: 01/08/14
DATE PRINTED: 01/10/14
REVISION
No. I DESCRIPTION I DATE:
SCOPE OF WORK:
1- REMOVE ALL INTERIOR GYPSUM WALL BOARD AND REPLACE
WITH MOISTURE RESISTANT GYP. BD.
2- NEW PLUMBING FIXTURES.
3- NEW LAVATORIES CABINETS.
4- NEW FAUCETS
5- REMOVE TUB AT BATHROOM #2 AND REPLACE WITH SHOWER.
BEDROOM ; FAMILY ROOMI
ii II
BATHROOM
BEDROOM
a ROOM
KITCHEN
DINING ROOM
i
i
i
1----------------------------------=--------------------------------it
BATHROOM RENOVATIONS
NORTH
EXISTING FLOOR PLAN TO REMAIN
SCALE: 1/4" -, o
GARAGE
LAUNDRY
MAIND'S ROOM
/(" y
"Dis�ppr�ved `..... ��11Ativ
L
7110/
0.7 20
i
W
z
JITJ
Wi
0
�
W
c°�
CWp0or-
0
1=
—�
(j)
Q
W
LLJ
0
im
O
a:
Q
gm
:9
O
cr
U
z
z
Q
m
J
F—
Q
JOB No, 14003
STARTED= 02/05/14
DATE PRINTED:02/05/14
REVISION
No. I DESCRIPTION DATE-
NO POINT ALONG COUPITER T() BE MOIL l HAN
2 FEET FROM G.F.I PIgn,CE ,j'ED RECEPTACLE.
PUT OM RECEPTACLE UNDER SINK.
ALL FIXED APPLIANCE" C) CKTS.
i
ELECTRICAL
COMMENTS #3
WINE
ZONING
C\TOPELECTRIC L
COUNTER TOP
0 OMMEN S #2
•
WINE
0
-'
PANTRY
co
KITCHEN
SCALE: 1/2" = 1'-0"
KITCHEN
SCALE: 1/2" = 1'-0"
ELECTRICAL
COM14ENTS #1
HOOD
COOK TOP
KITCHEN
SCALE: 1/2" = 1'-0"
WINE
ZONING
SINK
COUNTER TOP
•
�Iilk
0
-'
PANTRY
co
�',
REFRIG
COFFEE
D
II
I I
clr
��%'`�'
L
OVEN
o
TRASH
-�
1
DISHW
o
o
G�O1
I
4
KITCHEN
SCALE: 1/2" = 1'-0"
ELECTRICAL
COM14ENTS #1
HOOD
COOK TOP
KITCHEN
SCALE: 1/2" = 1'-0"
KITCHEN
2x P,T. WD. FASTEI`
TO CONC. SLAB W/DN3
"HILTI" SHOTS `q 16 C
OR TO WOOD FLOOR
1" WOOD SCREWS L 16" C
LINE OF WOOD TRUSSES
STUD GA. 20 TRACK
FASTENED TO WOOD
MEMBER W/1" WOOD
SCREWS @ 16" O.C. OR
TO CONC. SLAB W/ DN37P8
"HILTI" SHOTS @ 16 O.C.
3 5/8" METAL STUD GA.20
OR 2x4 WD. STUD ® 24" O.C. PAAX
5/8" G.W.B. NAILED TO
STUDS (REFER TO
FASTENING NOTES)
FLOOR FINISH
LINE OF CONC. SLAB
ELECTRICAL
COMMENTS #10
INTERIOR PARTITION DETAIL
SCALE: 3/4" = 1'-0"
R702.3.6 FASTENING.
SCREWS FOR ATTACHING GYPSUM BOARD TO WOOD FRAMING SHALL BE
TYPE W OR TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL
PENETRATE THE WOOD NOT LESS THAN 5/8 INCH (15.9 MM). SCREWS FOR
ATTACHING GYPSUM BOARD TO LIGHT -GAGE STEEL FRAMING SHALL BE
TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL PENETRATE THE
STEEL NOT LESS THAN 3/8 INCH (9.5 MM). SCREWS FOR ATTACHING
GYPSUM BOARD TO STEEL FRAMING 0.033 INCH TO 0.112 INCH (0.838 MHA
TO 2.84 MM) THICK SHALL COMPLY WITH ASTM C 954.
ELECTRICAL
COMMENTS #5
NEW CEILING LIGHTING (TYP.)
O O
O
BEDROOM /
EXISTING-
WOOD
O O
BATH #1
BATHROOM
I I
I I I I
I I I I
O II
I I I I
ELECTR GAL
O COMMS rs #4
O
O
I SD
I
0 EXISTING
txTWOOD
O
BEDROOM
EXISTING
f WOOD
UILDING
COMMENTS
NOTES:
1.- ALL EXTERIOR WALL WITH NEW PLASTER AND PAINT.
2.- KITCHEN CABINETS TO BE FIEPLACED.
3.- NEW MARBLE AND WOOD FLOORING PER LOCATIONS
REFER TO FLOOR PLAN.
FAMILY ROOM
�NEW--"*'�
1' MARBLE
UPPER
CABINET
MICROW,
OVEN
COFFEE
AT 76" F. F. F.
PANTRY
LIVING ROOM
GARAGE
-NEW)
r MARBLE
�
WINE
ZONING
COUNTER TOP
•
�Iilk
0
-'
MICROW
co
�',
REFRIG
COFFEE
D
II
I I
0
PANTRY
OVEN
0
-�
1
I cFcl
o
o
G�O1
I
4
A-2
2
�LcFcl
l�
DISHWASHER
I
KITCHEN
2x P,T. WD. FASTEI`
TO CONC. SLAB W/DN3
"HILTI" SHOTS `q 16 C
OR TO WOOD FLOOR
1" WOOD SCREWS L 16" C
LINE OF WOOD TRUSSES
STUD GA. 20 TRACK
FASTENED TO WOOD
MEMBER W/1" WOOD
SCREWS @ 16" O.C. OR
TO CONC. SLAB W/ DN37P8
"HILTI" SHOTS @ 16 O.C.
3 5/8" METAL STUD GA.20
OR 2x4 WD. STUD ® 24" O.C. PAAX
5/8" G.W.B. NAILED TO
STUDS (REFER TO
FASTENING NOTES)
FLOOR FINISH
LINE OF CONC. SLAB
ELECTRICAL
COMMENTS #10
INTERIOR PARTITION DETAIL
SCALE: 3/4" = 1'-0"
R702.3.6 FASTENING.
SCREWS FOR ATTACHING GYPSUM BOARD TO WOOD FRAMING SHALL BE
TYPE W OR TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL
PENETRATE THE WOOD NOT LESS THAN 5/8 INCH (15.9 MM). SCREWS FOR
ATTACHING GYPSUM BOARD TO LIGHT -GAGE STEEL FRAMING SHALL BE
TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL PENETRATE THE
STEEL NOT LESS THAN 3/8 INCH (9.5 MM). SCREWS FOR ATTACHING
GYPSUM BOARD TO STEEL FRAMING 0.033 INCH TO 0.112 INCH (0.838 MHA
TO 2.84 MM) THICK SHALL COMPLY WITH ASTM C 954.
ELECTRICAL
COMMENTS #5
NEW CEILING LIGHTING (TYP.)
O O
O
BEDROOM /
EXISTING-
WOOD
O O
BATH #1
BATHROOM
I I
I I I I
I I I I
O II
I I I I
ELECTR GAL
O COMMS rs #4
O
O
I SD
I
0 EXISTING
txTWOOD
O
BEDROOM
EXISTING
f WOOD
UILDING
COMMENTS
NOTES:
1.- ALL EXTERIOR WALL WITH NEW PLASTER AND PAINT.
2.- KITCHEN CABINETS TO BE FIEPLACED.
3.- NEW MARBLE AND WOOD FLOORING PER LOCATIONS
REFER TO FLOOR PLAN.
FAMILY ROOM
�NEW--"*'�
1' MARBLE
UPPER
CABINET
MICROW,
OVEN
COFFEE
AT 76" F. F. F.
PANTRY
LIVING ROOM
GARAGE
-NEW)
r MARBLE
�
WINE
ZONING
•
�Iilk
-'
IL
•
�',
---_- -
------
II
I I
ELECTRICAL
PANTRY
-�
1
I cFcl
UPPER
CABINET
G�O1
I
I
� NEW
JO i � ' MARBLE
i
r COUNTER TOP
ELECTRICAL
EXISTING COMMENTS #6
WOOD
II
it
II
II
II
II
II
II
II
II
II
II
II
II
II
O
ELECTRICAL
COMMENT -07
EXISTING
WOOD
0
DINING ROOM
a
O O
I
I
I
I
I
I
I
I
I
I
L--------------------------------- --------------------------------'�
INTERIOR RENOVATIONS
NORTH
77�
EXISTING FLOOR PLAN TO REMAIN
I
I '
I
I
I
a
NEW—/
WOOD
a
NEW
WOOD
MAIND'S ROOM
APPROVED
WINE
ZONING
O
O
-'
S,RJCTURAL
r---
I
---_- -
------
II
I I
ELECTRICAL
PANTRY
-�
1
I cFcl
UPPER
CABINET
G�O1
I
4
A-2
2
�LcFcl
l�
DISHWASHER
I
3
�
SUBJECT To
KITCHEN
-
SINK W/
GARBAGE
JO
DISPOSAL
TRASH
fNEW
MARBLE
GFCI
UPPER
CABINET
O O
_----
GFci
EXISTING
-----
ELECTRICAL
IIRifAfl' AND
COMMH6iiD9#6
ELOUTLETS
COMMENTS #9
ELECTRICAL
EXISTING COMMENTS #6
WOOD
II
it
II
II
II
II
II
II
II
II
II
II
II
II
II
O
ELECTRICAL
COMMENT -07
EXISTING
WOOD
0
DINING ROOM
a
O O
I
I
I
I
I
I
I
I
I
I
L--------------------------------- --------------------------------'�
INTERIOR RENOVATIONS
NORTH
77�
EXISTING FLOOR PLAN TO REMAIN
I
I '
I
I
I
a
NEW—/
WOOD
a
NEW
WOOD
MAIND'S ROOM
APPROVED
CEI "Y ED
APR 2 2814
.uP
ail
r ,
,1
Ell'
i c j
i C�• � V.� i4
BY OA'
JOB No.
"34/07/14- `
i?91NTE-04/08/14`
No ` DL�iIPTK?N DATE
1 B �: �OM�AEIVTS 4/22/14;;
ii
ZONING
-'
S,RJCTURAL
f �c
��
f
G
ELECTRICAL
PLUMBING
oAq
w PriECFIAN:CAL
l�
g
CIO
On
1 BLDG.
SUBJECT To
.CilliTE AND C
CEI "Y ED
APR 2 2814
.uP
ail
r ,
,1
Ell'
i c j
i C�• � V.� i4
BY OA'
JOB No.
"34/07/14- `
i?91NTE-04/08/14`
No ` DL�iIPTK?N DATE
1 B �: �OM�AEIVTS 4/22/14;;
ii
ii