Loading...
RC13-2871Miami Shores Village q ( g Building Department artment DEC 2 7 �U 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 ' a l l INSPECTION'S PHONE NUMBER: (305) 762.4949 1231 �i3�mA-CA-0 FBC20 BUILDING Permit No. PERMIT APPLICATION Master Permit No.hC �3 — r:2S-7/ Permit Type: BUILDING ROOFING JOB ADDRESS: 3 `at O N C 0\ S� . City: Miami Shores County: C Folio/Parcel#: - -F N _0 0 1 -3 IR 0 q 7-4 3 Is the Building Historically Designated: Yes OWNER: Name (Fee Simple Titleholder): LI rl(R Address: 3pi J � V t Cl �) SA City: State: Tenant/Lessee Name: Email: NO 1 o V4 — 61 (A — N --- 7 1 _Flood Zone: �1�() z' �o s 521+ 4 1 /16 hone#: ZO� � % CONTRACTOR: Company Name; S LPA Go NS'�'iR-il C-J�' 1011 l tgC­Phone#: .� '0 5 � V 5q'l r O 3 J Address: k'8 \ S \�( k 38 CSG City: MX X11 State: �'' Zip: 33 t8G Qualifier Name: E la -k C- S ��—}� � Phone#: 3OS " 4t -z_(3 S� State Certification or Registration #: C_ C. So"1•�1 "Z Certificate of Comp ten #: Contact Phone#: Email Address: S qCA ���0 • Yie, DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: Type of Work: ❑Addition Description.of Work:�'�- r Square/Linear Footage of Work:. ' Alteration ❑New ❑Re air/Replace ❑Demolition Color thru tile: Submittal Fee $Ji ,J` 0, 00 Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Notary $ Double Fee $ Radon Fee $ Training/Education Fee $ tructural Review $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE -L ELCTRICAL NOTES 1- ALL ELPCTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIOrIAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2- ELECTPICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 3- ALL ELI=CTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTI"ICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION, AS REQUIRED. 4- SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE V�JITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH (,HANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER. 5- UP SUC%H TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. 6- ALL CCINDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUI'ID CONDUCTOR PER NEC 250-122. 7- CIRCUIT NUMBERS SHOWN ARE FOR CALCULATIONPURPOSES ONLY. ACTUAL CIRCUITING MAY VARY ACCORDING TO NEC AND FBC PROVVE PANEL SCHRDULE AFTER COMPLETION. 8- EXTERIOR DISCONECT SUBJECT TO RAIN MUST BE N -3R UL. 9- GROUI,IDING TO INCLUDE LOW VOLT SYSTEM BONDING NEC 250.94 10- THE LIGHTING COMPLIES WITH THE FBC E 404.1. LOAD COMPUTATION PANEL (A) GENERAL LIGHTING 2,379 SQ. FT. @ 3W/SQ. FT. WATTS CKT SMALL APPLIANCE CIRCUITS: 3 CIRCUITS x 1500 FIXED APPLIANCES: 8 #12 / 1/2"C GENERAL LIGHT./RECEP RANGE 12,000 DRYER 5,000 WASHER 1,500 REFRIGERATOR 1,500 DISHWASHER 1,000 WATER HEATER 5,500 MICI11OWAVE 1,500 GARBAGE DISPOSER 600 ALARM 800 EX-fERIOR WP/GFI 720 WHIRLPOOL (FUTURE) 2000 WINE COOLER 1500 RANGE HOOD EXHAUST FAN 600 GARAGE DOOR OPENER 800 POOL EQUIPMENT (FUTURE) 2,800 POOL HEATER (FUTURE) 7,000 20 CONNECTED LOAD LESS A/C = 56,457 W 720 10,00ow c 100% = 10,000 REST W @ 40% = 46,457 18,583 A/C (OR HEATING) @ 65% = 10,200 DEMAND LOAD: 38,783 /240 WATTS = 161.60 AMPS 240/120 PANEL SIZE = 200 AMPS NOTES: A/C @ 100% = 10,200 HEAT @ 65% = 6,630 ELECTRICAL RISER EXISTING 120/240 V, 3 WIRE, 1 -PHASE # 3/0 THWN, Cu IN 2" RIGID CONDUIT LEGEND []� FUSE OR DISCONNECT SWITCH Simon ELECTRIC PANEL MD ELECTRIC METER SCOPE OF WORK: 1- REMOVE ELECTRICAL PANEL 2- NEW ELECTRICAL PANEL (PEE LOCATED) O.H. ELECTRIC SERVICE FROM FPL TRANSFORMER (NTS) EXISTING 3 # 3/0 & 1 44 THWN (CU.) IN 2" COND. NEW 3 #3/0 THWN ((AJ ` IN 2" COND. PANEL A EXISTING NEk,V 200 AMP. 2XI AMP ELECTRICAL ELECTRICAL PAldl_:L BOARD METER0 WATERPROOF Afrr=RPROOF GROUNDING TO INCLUDE LOW VOLT SYSTEM RnNnING IFC 250.94 ■■ EXISTING 200 AMP DISC. BIRK'R WATER PROOF EXISTING 1 #4 CU IN 1/2" G'__yND. TO 1/2" COLD WATER PIPE EXISTING 1 #4 CU (GN'D. PER N.E.0 CWP (METAL) GRADE�� 1-5/8" COPPERCLAD GROUND ROD '10 FT. LONG BUILDING STEEL FOIJNDA'I :ON CONCRETE -ENCASED ELECTRODE: AN ELECTRODE ENCASED BY AT LEAST 2 INCHES (50.8 mm) OF CONCRETE, LOCATED WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTIW:1 THAT IS IN DIRECT CONTACT WITH THE EARTH, CONSISTING OF AT LEAST 20 FEET (6.1 m) OF ONE (ifs MORE STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2 INCH (12.7 mm) DIAMETER, OR CONSISTING OF AT LEAST 20 FEET (6.1 mm) OF BARE COPPER CONDUCTOR NOT SMALLER THAN No. 4 AWG. I TYPE: SQUARE "D" OR EQUIVALENT APPROVED VOLTAGE: 240/120V /\ � j � � : /� A VOLTAGE: 200A PJA MOUNTING: SURFACE / WATER PROOF — AMPS POLES TOTAL VA WIRE/ DESCRIPTION CONDUIT CKT 20 1 8 #12 / 1/2"C GENERAL LIGHT./RECEP 1 20 1 REFRIGERATOR #12 / 1/2"C GENERAL LIGHT./RECEP 3 20 1 18 #12 / 1/2"C GENERAL LIGHT./RECEP 5 20 1 WASHER #12 / 1/2"C GENERAL LIGHT./RECEP 7 20 1 720 #12 / 1/2"C EXT. WP/GFI & RECEPT. 9 20 I 1500 #12 / 1/2"C WINE 11 20 1 1500 #12 / 1/2"C SMALL APPL 13 20 1 1500 #12 / 1/2"C SMALL APPL 15 20 1 1500 #12 / 1/2"C SMALL APPL 17 20 1 1500 #12 / 1/2"C MICROWAVE 19 20 1 k #12 / 1/2"C GENERAL LIGHT./RECEP 21 20 1 '1500 1#12 / 1/2"C DISHWASHER 23 40 2 5500 8 / 3/4"C WATER HEATER 25 20 2 2800 #12 / 1/2"C POOL PUMP (FUTURE) 27 29 1 40 1 2 1 2800 W8 / 3/4"C (POOL HEE 1 20 1 2 12000 P12 / 1/2"C IWHIRPOC 20 I1 1#12 / 1/2"C ISPARE 20 1k #12 / 1/2"C ISPARF DEMAND LOAD: 38,783 W = 161.60 AMPS. (SEE LOAD CALCULATION) CKT. (DESCRIPTION 2 DRYER 4 20 6 GENERAL LIGHT. 8 GENERAL LIGHT. 10 BATH LGTS. 12 REFRIGERATOR 14 A/C AHU 16 18 _ KIT./BATH LGTS. 20 RECEPTACLES 22 WASHER 24 GENERAL LIGHT. 26 RANGE 28 cl) 30 CONDENSING UNIT MAIN BUS: 200 AMP. NEUTRAL: 200 AMP. MAINS: 200 AMP LOCATION: EXTERIOR VIRE: / OTAL POLES AMPS ;ONDUIT VA '101 1 /2"C 5000 1 2 1 30 10 2 / 1/2"C 1 20 #12 / 1/2"C 1 20 f114 / 1/2"C 1 20 #12 / 1/2"C 1500 1 20 #6 / 3/4"C 10200 2 60 X14 /,1/2"C * 1 20 :14/1/2"C * 1 20 12/1/2"C 1500 1 20 L'14/1/2"C 1 20 #6l3/4"C 12000 2 50 / 3/4"C 16200 1 2 1 50 EXISTING OVERHEAD ELECTRICAL SERVICES FEEDER TO POWER JAN 2 120'14 NORTH EXISTING FLOOR PLAN TO REMAIN SCALE: ,,a -, O r Ni W a W OL n O J Z F Ww V3 W F— J J of cl) OU 3 o— Wp 0a 8 JOB No. 14003 STARTED: 01/08/14 DATE PRINTED: 01/10/14 REVISION No. I DESCRIPTION I DATE: W \ J Z z a cl) o— w W a I (1)U 0Cc� � IL�—a�= � U cc CLJa W U z zZ -I � F— a � JOB No. 14003 STARTED: 01/08/14 DATE PRINTED: 01/10/14 REVISION No. I DESCRIPTION I DATE: SCOPE OF WORK: 1- REMOVE ALL INTERIOR GYPSUM WALL BOARD AND REPLACE WITH MOISTURE RESISTANT GYP. BD. 2- NEW PLUMBING FIXTURES. 3- NEW LAVATORIES CABINETS. 4- NEW FAUCETS 5- REMOVE TUB AT BATHROOM #2 AND REPLACE WITH SHOWER. BEDROOM ; FAMILY ROOMI ii II BATHROOM BEDROOM a ROOM KITCHEN DINING ROOM i i i 1----------------------------------=--------------------------------it BATHROOM RENOVATIONS NORTH EXISTING FLOOR PLAN TO REMAIN SCALE: 1/4" -, o GARAGE LAUNDRY MAIND'S ROOM /(" y "Dis�ppr�ved `..... ��11Ativ L 7110/ 0.7 20 i W z JITJ Wi 0 � W c°� CWp0or- 0 1= —� (j) Q W LLJ 0 im O a: Q gm :9 O cr U z z Q m J F— Q JOB No, 14003 STARTED= 02/05/14 DATE PRINTED:02/05/14 REVISION No. I DESCRIPTION DATE- NO POINT ALONG COUPITER T() BE MOIL l HAN 2 FEET FROM G.F.I PIgn,CE ,j'ED RECEPTACLE. PUT OM RECEPTACLE UNDER SINK. ALL FIXED APPLIANCE" C) CKTS. i ELECTRICAL COMMENTS #3 WINE ZONING C\TOPELECTRIC L COUNTER TOP 0 OMMEN S #2 • WINE 0 -' PANTRY co KITCHEN SCALE: 1/2" = 1'-0" KITCHEN SCALE: 1/2" = 1'-0" ELECTRICAL COM14ENTS #1 HOOD COOK TOP KITCHEN SCALE: 1/2" = 1'-0" WINE ZONING SINK COUNTER TOP • �Iilk 0 -' PANTRY co �', REFRIG COFFEE D II I I clr ��%'`�' L OVEN o TRASH -� 1 DISHW o o G�O1 I 4 KITCHEN SCALE: 1/2" = 1'-0" ELECTRICAL COM14ENTS #1 HOOD COOK TOP KITCHEN SCALE: 1/2" = 1'-0" KITCHEN 2x P,T. WD. FASTEI` TO CONC. SLAB W/DN3 "HILTI" SHOTS `q 16 C OR TO WOOD FLOOR 1" WOOD SCREWS L 16" C LINE OF WOOD TRUSSES STUD GA. 20 TRACK FASTENED TO WOOD MEMBER W/1" WOOD SCREWS @ 16" O.C. OR TO CONC. SLAB W/ DN37P8 "HILTI" SHOTS @ 16 O.C. 3 5/8" METAL STUD GA.20 OR 2x4 WD. STUD ® 24" O.C. PAAX 5/8" G.W.B. NAILED TO STUDS (REFER TO FASTENING NOTES) FLOOR FINISH LINE OF CONC. SLAB ELECTRICAL COMMENTS #10 INTERIOR PARTITION DETAIL SCALE: 3/4" = 1'-0" R702.3.6 FASTENING. SCREWS FOR ATTACHING GYPSUM BOARD TO WOOD FRAMING SHALL BE TYPE W OR TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL PENETRATE THE WOOD NOT LESS THAN 5/8 INCH (15.9 MM). SCREWS FOR ATTACHING GYPSUM BOARD TO LIGHT -GAGE STEEL FRAMING SHALL BE TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL PENETRATE THE STEEL NOT LESS THAN 3/8 INCH (9.5 MM). SCREWS FOR ATTACHING GYPSUM BOARD TO STEEL FRAMING 0.033 INCH TO 0.112 INCH (0.838 MHA TO 2.84 MM) THICK SHALL COMPLY WITH ASTM C 954. ELECTRICAL COMMENTS #5 NEW CEILING LIGHTING (TYP.) O O O BEDROOM / EXISTING- WOOD O O BATH #1 BATHROOM I I I I I I I I I I O II I I I I ELECTR GAL O COMMS rs #4 O O I SD I 0 EXISTING txTWOOD O BEDROOM EXISTING f WOOD UILDING COMMENTS NOTES: 1.- ALL EXTERIOR WALL WITH NEW PLASTER AND PAINT. 2.- KITCHEN CABINETS TO BE FIEPLACED. 3.- NEW MARBLE AND WOOD FLOORING PER LOCATIONS REFER TO FLOOR PLAN. FAMILY ROOM �NEW--"*'� 1' MARBLE UPPER CABINET MICROW, OVEN COFFEE AT 76" F. F. F. PANTRY LIVING ROOM GARAGE -NEW) r MARBLE � WINE ZONING COUNTER TOP • �Iilk 0 -' MICROW co �', REFRIG COFFEE D II I I 0 PANTRY OVEN 0 -� 1 I cFcl o o G�O1 I 4 A-2 2 �LcFcl l� DISHWASHER I KITCHEN 2x P,T. WD. FASTEI` TO CONC. SLAB W/DN3 "HILTI" SHOTS `q 16 C OR TO WOOD FLOOR 1" WOOD SCREWS L 16" C LINE OF WOOD TRUSSES STUD GA. 20 TRACK FASTENED TO WOOD MEMBER W/1" WOOD SCREWS @ 16" O.C. OR TO CONC. SLAB W/ DN37P8 "HILTI" SHOTS @ 16 O.C. 3 5/8" METAL STUD GA.20 OR 2x4 WD. STUD ® 24" O.C. PAAX 5/8" G.W.B. NAILED TO STUDS (REFER TO FASTENING NOTES) FLOOR FINISH LINE OF CONC. SLAB ELECTRICAL COMMENTS #10 INTERIOR PARTITION DETAIL SCALE: 3/4" = 1'-0" R702.3.6 FASTENING. SCREWS FOR ATTACHING GYPSUM BOARD TO WOOD FRAMING SHALL BE TYPE W OR TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL PENETRATE THE WOOD NOT LESS THAN 5/8 INCH (15.9 MM). SCREWS FOR ATTACHING GYPSUM BOARD TO LIGHT -GAGE STEEL FRAMING SHALL BE TYPE S IN ACCORDANCE WITH ASTM C 1002 AND SHALL PENETRATE THE STEEL NOT LESS THAN 3/8 INCH (9.5 MM). SCREWS FOR ATTACHING GYPSUM BOARD TO STEEL FRAMING 0.033 INCH TO 0.112 INCH (0.838 MHA TO 2.84 MM) THICK SHALL COMPLY WITH ASTM C 954. ELECTRICAL COMMENTS #5 NEW CEILING LIGHTING (TYP.) O O O BEDROOM / EXISTING- WOOD O O BATH #1 BATHROOM I I I I I I I I I I O II I I I I ELECTR GAL O COMMS rs #4 O O I SD I 0 EXISTING txTWOOD O BEDROOM EXISTING f WOOD UILDING COMMENTS NOTES: 1.- ALL EXTERIOR WALL WITH NEW PLASTER AND PAINT. 2.- KITCHEN CABINETS TO BE FIEPLACED. 3.- NEW MARBLE AND WOOD FLOORING PER LOCATIONS REFER TO FLOOR PLAN. FAMILY ROOM �NEW--"*'� 1' MARBLE UPPER CABINET MICROW, OVEN COFFEE AT 76" F. F. F. PANTRY LIVING ROOM GARAGE -NEW) r MARBLE � WINE ZONING • �Iilk -' IL • �', ---_- - ------ II I I ELECTRICAL PANTRY -� 1 I cFcl UPPER CABINET G�O1 I I � NEW JO i � ' MARBLE i r COUNTER TOP ELECTRICAL EXISTING COMMENTS #6 WOOD II it II II II II II II II II II II II II II O ELECTRICAL COMMENT -07 EXISTING WOOD 0 DINING ROOM a O O I I I I I I I I I I L--------------------------------- --------------------------------'� INTERIOR RENOVATIONS NORTH 77� EXISTING FLOOR PLAN TO REMAIN I I ' I I I a NEW—/ WOOD a NEW WOOD MAIND'S ROOM APPROVED WINE ZONING O O -' S,RJCTURAL r--- I ---_- - ------ II I I ELECTRICAL PANTRY -� 1 I cFcl UPPER CABINET G�O1 I 4 A-2 2 �LcFcl l� DISHWASHER I 3 � SUBJECT To KITCHEN - SINK W/ GARBAGE JO DISPOSAL TRASH fNEW MARBLE GFCI UPPER CABINET O O _---- GFci EXISTING ----- ELECTRICAL IIRifAfl' AND COMMH6iiD9#6 ELOUTLETS COMMENTS #9 ELECTRICAL EXISTING COMMENTS #6 WOOD II it II II II II II II II II II II II II II O ELECTRICAL COMMENT -07 EXISTING WOOD 0 DINING ROOM a O O I I I I I I I I I I L--------------------------------- --------------------------------'� INTERIOR RENOVATIONS NORTH 77� EXISTING FLOOR PLAN TO REMAIN I I ' I I I a NEW—/ WOOD a NEW WOOD MAIND'S ROOM APPROVED CEI "Y ED APR 2 2814 .uP ail r , ,1 Ell' i c j i C�• � V.� i4 BY OA' JOB No. "34/07/14- ` i?91NTE-04/08/14` No ` DL�iIPTK?N DATE 1 B �: �OM�AEIVTS 4/22/14;; ii ZONING -' S,RJCTURAL f �c �� f G ELECTRICAL PLUMBING oAq w PriECFIAN:CAL l� g CIO On 1 BLDG. SUBJECT To .CilliTE AND C CEI "Y ED APR 2 2814 .uP ail r , ,1 Ell' i c j i C�• � V.� i4 BY OA' JOB No. "34/07/14- ` i?91NTE-04/08/14` No ` DL�iIPTK?N DATE 1 B �: �OM�AEIVTS 4/22/14;; ii ii