Loading...
MC13-2723Miami Shores Village LNBuilding Depbrtment PERMIT APPLICATION ❑BUILDING ❑PLUMBING ❑ ELECTRIC MECHANICAL 19 JOB ADDRESS: 3-1c) "V 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 SEP 2 6 2014 FBC 20 1 C� �1N(�S. �! 1- �. Master Permit No R 03 _Zt�'� Sub Permit No. 1y) C 13—.2-72-D 2-D ❑ ROOFING WREVISION ❑ EXTISION F-1 PUBLIC WORKS ❑ CHANGE OF CONTRACTOR C. 3' ❑ CANCELLATION ❑ RENEWAL ❑ SHOP DRAWINGS City: Miami Shores County: Miami Dade Zip: Q Folio/Parcel#: Is the Building Historically Designated: Yes NO '' OccupanEy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): 'PR-vc 1 C",-- be',s 07 ( d I I {e S Phone#: 34) S 5 2-14-1L Address: Al 1L G AS t 1 am r S h c)res City: ,(L ni t Yl r3 l '� State: TL. Zip: 33 BE Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Cei► YTraL C Mn QCT A 10. L° IW Phone#: Address: a (<b SU) V City: Nam, State: RG Zip: Qualifier Name: 'e� `' V�L�n Q � Phone#: State Certification or Registration #: Certificate Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: Value of Work for this Permit: $ IJV Square/Linear Footage of Work: te: Zip: t Type of Work: ❑ Addition p (( M Alteration f ❑ New r ❑ Repair/Replace ❑ Demolition Description of Work:` Specify color of color thru tpe: Submittal Fee $ Permit Fee $ �' CCF $ CO/CC $ Scanning Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE s MECHANICAL SCOPE OF WORK: — IS LIMITED TO RELOCALIZE THE MAIN RETURN DUCT TO NEW LOCATION AS SPECIFY IN THIS PLAN, Bathroom Bathroom Laundry RoJm ?4X30 R /A W/FILTER n n1 attic space Existing Return Shall be Sealed with Drywall 0 \ [FAMrAlIF11l —Existing O A-41 04K Adt' Trane / model:GAM5BO36 .E �. LINES OVER HEAD TO AHU —1, ;.e_turn Plenum nsulated with Fiberglass r-6 Garagernt 10x20 rxistin C U Fiberc�la s —6 protected in garage Trane g/ model:4TTB6036 with Sh metal 26ga I 0 H. V. A" C. GENERAL NOTES: (WHEN APPLY) ALL WORK SHALL CONFORM WITH THE FLORIDA BUILDING CODE 2010, NFPA, NEC, AND ALL OTHER APPLICABLE FEDERAL, STATC AND LOCAL REGULATIONS AND ORDINANCES. CONTRACTOR SHALL SECURE AND PAY [-'OR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, PERFORMANCE BONDS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE MECHANICAL SYSTEMS, AND SHALL BE RESPONSIBLE FOR OBTAINING HiS OWN PERMIT. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAOE FOR THE DURATION OF THE WORK, ALSO VERIFY EXISTING CONDITIONS BEFORE START THE JOB, SUBMIT SHOP DRAWING OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO FABRICATION. MEHCANICAL PLANS ARE DIAGRAMATIC,AND MAY CHANGE DUE TO FIELD CONDITIONS. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH 30 GAUGES, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN IHE LATEST EDITION OF THE A.S.H.R.A.E. GUIDE AND S.M.A.C.N.A, STANDARDS. DUCT SIZES SHOWN ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGF�ESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICAL]ILE CODES AND STANDARDS. SUBMIT SHOP DRAWING OF ALL MATERIALS AND EQUIPMENT FOR APPROVAL PRIOR TO FABRICATION. GENERAL/MECHANICAL CONTRACTOR SHALL BE VERIFY ALL INSULATION VALUE USED FOR CALCUALTUIONS IN ENERGY AND/OR HEAT LOAD PROVIDED BY MECHANICAL ENGINEER. CUT ALL OPENINGS AND CHASES REQUIRED TO ACCOMODATE THE WORK UNDER THIS DIVISION, AND REPAIR ALL FLOORS, WALLS, ETC., DAMAGED BY SUCH CUTTINGS, ALL WORK DONE UNDER THIS HEADING MUST CONFORM IN EVERY RESPECT TO FINISH AND QUALITY OF MATERIALS AND WORKMANSHIP SPECIFIED UNDER APPROPIATE SECTIONS FOR THE BUILDING. MECHANICAL CONTRACTOR SHALL BE RESPONSABLE FOR AIR BALANCE ACORDING WITH PLAN. ALL DUCTWORK RUNNING IN CONDITIOINEO SPACE COULD BE R-4 AND DUCTWORK RUNNING IN UNCONDITIONED SPACE SHALL BE I? -6 MIN INSUATION. PROVIDE 1" UNDERCUT AT ALL INTERIOR DOORS. MECHANICAL FLOOR PLAN SCALE: 3/16" = 1' Supply 410 MIN WALL A OUND AF U REFIRIG LINES A.I-I.U. PRIMARY DRAIN LINE TO EXTERIOR T FILTER return) PROVIDE 4" CLEAR ALL AROUND AHU ELOV SNITCH @ SECIONCARY DRAIN LINE I SUL�TED DRYWALL ETURN BOX / FBERGLASS DUCTBOARD R-6 AHU AT GARAGE INSTALLATION DETAIL NTS MAINTAIN MFRS RECOMMENDED CLEARANCES FOR AIRFLOW AND MAINTENANCE ACCESS COND. UNIT TO BE SECURED WITH (4) 140A GALV STEEL CLIP 1"0". TO SUPPORTING 165 MPF CONDENSING UNIT d ..A d 'd4 d CONCRETE PAD TYPICAL CONDENSING UNIT MOUNTING DETAIL N.T.S. am FLEXIBLE DUCT INSTALLATION AND SUPPORT, FLEXIBLE DUCTS SFIALL BE CONFIGURED AND SUPPORTED SO AS TO PREVENT THE USE OF EXCESS DUCT MAIERA, PREVENT DUCT DISLOCATION OR DAMAGE, AND PREVENT CONSTRICTION Of THE DUCT BELOW THE RATED DUCT DIAMETER IN ACCORDANCE MfiH THE FOLLOWING REQUIREMENTS: 1. DUCTS SHALL BE INSTALLED FULLY EXTENDED, THE TOTAL EXMFNOED LENGTH OF DUCT MATERW. SHALL NOT EXCEED 5 PERCENT OF THE MINIMUM REQUIRED LENGTH FOR THAT RUN. 2, LENDS SHALT. MAINTAIN A CUM LINE RADIUM OF NOT LESS THAN ONE DUCT DIAMETER. 3. TERMINAL DEVICES SHALL. BE SUPPORTED INDEPENDENTLY OF THE FLEXIBLE DUCT. 3, HORIZONTAL DUCT SHALL BE SUPP090 AT INTERVALS NOT GREATER THAN 5 FEET. DUCT SAO BETNiIIN SUPPORTS SHALL NOT EXCEED 1/2 INCH PER FOOT OF LENGTH. SUPPORTS SHUT BE PROVIDED WFIHN 1.5 FEET OF INTERMEDIATE FITTINGS AND BETWEEN MEDIATE FITTINGS AND BENDS. CEILING JOISTS AND RIM DUCTS OR EQUIPMINf SWM. BE CONSIDERED TO BE SUPPOTS. 5. VERTICAL DUCT SEOUL BE STABLLIZED WITH SUPPORT STRAPS AT INTMALS NOT GREATER THAN 6 FEET. 6. HANGERS, SADDLES AND OTHER SUPPORTS SHALL MEET THE DUCT MANUFACTURER'S RECOMMENDATIONS AND SHALL BE OF SUFFICIENT WIDTH TO PREVENT RESTRICTION OF THE INTERNAL DUCT DIAMETER. IN NO CASE SHALL THE MATERIAL SUPPORTING FLEXIBLE DUCT THAT IN DIRECT CONTACT WITH IT BE LESS THAN 1/2 INCHES WIDE. TH SPIN COLLAR FITTING WITH EXTRACTOR AND VOLUME DAMPER. QUADRANT — T0 DE OUTSIDE INSULATION, PROVIDE INSULATION GUARD WHERE NECASSARY. CONNECTION SHALL BE AT THE NZ SIDE OF PLENUM AS SPACE ALELOW VEIDCITY RETURN UCT (SEE PUN FLEX DUCT DINT WITH DUCT AIR RAW SCREWS PER CLIP C U HOUSING 0 GALV 1 SCREWS PER CLIP TO CONCRETE PAD 1/4"X2" TAPCON T=i/4" MIN EMBEDMENT STANDARD 3" WiDE HANGERS Hangot extension to be the sum of the distances between the hanging wt— end the duct e1ze. 10 ISmarnal Duct size, Inches Maximum Hangs Spacing 48: Wide or grater 4 ft Lose tho 48 wide Eft and less than 48" / deep INSULATED PLENUM Width between 28" Eft do 48" and greater than deep Extension is Channel Channel t1h6a" ands 16" ndi% ord?ass 8ft not greater than: Gauge Profile N1ami Shore S Village APPROVEDBY DATE "�. DEPT Lk _?t._DG DEPT � ► P[ IANCE WITH ALL FEDERAL Y 13111 FS ANF) REGULATIONS Revisions CHANNEL SECTION / . INSULATED PLENUM if Total Minimum Minimum z Extension is Channel Channel O not greater than: Gauge Profile \--CEJUNG 6" 24 3" X 1.5" DIFFUSER 18" 22 3" X 2" p<w 30" 16 3" X 2" FLEXIBLE DUCT CONNECTIONS DETAIL (TYPICAL) NTS USE OF 2" WOE 000 2 22 gauge 2'x 1.5" hangers moy be substituted 4GTHDIFFUSERI K MAXIMUM LENGTH OF FLIXIME DUCT for 3" hangers for ducts with widths not over 48" RUNOUT TO 10 FEET and depths not over 24" provided that not more than one joint occurs between hangers and the maximum hanger pacing 4fL Excption: When W' duct Perimeteris 80" or less and does not L.. c require reinforcement two joints are permitted 0 bspween hangers Revisions z O V �- p<w Q W� r LL WacC/)W Q 000 2 Z<U) W� r J z 0 W' L.. c 0 O m 'I L U)L0 00 L0 N o � v N L0 1 ll I00 N C,0 > ILl 4;: C0 `Y. Z L <—Lc C Qa a ,M in �W y W a a�� 1 N J U � a � U Q m v T2 00 m . U z U w F^ z U RY a Job No. Date Scale Q .0 0 Seal' AA -26001560 Sheet No. M-1 V