RF-14-2047s r � 1"tsPeoTa�e rh1j7 ENS 7066 SW 44"' Street Miarri, FL 33155 Tei: 786-398-9179 Fax: 786-800-2627 LAS CERTIFICATION #10-0512•01 SITE SPECIFIC INFORMATION UPLIFT TEST — TAS #106 Roofing Contractor BUILDING UNLIMITED Job Address 925 NE 98 ST MIAMI SHORES, FL. 33138 Owner's Name TONY LOCKHART Type of Tile BORAL FLAT 13" Approximate Roof Height 12' feet Roof Pitch 3112 Approximate Square Footage of Roof 30 ft2 Date Tested 01/27/15 Number of Tests 76 Contact Marne MARTw Permit # RS -9-14-2047 Hate Installed Type of Access to Roof LADDER Required Testing Force 35 Lbs Testing Equipment F.G.E.100 Phone # 3/64!9-5763 LOCATION # OF TEST PASS # OF TEST FAIL Corner 12 Tests 12 Pass Test 0 Fail Perimeter 11 Tests 11 Pass Test 0 Fail Field 35 Tests 35 Pass Test 0 Fail Ridge 18 Tests 18 Pass Test 0 Fail TOTAL 76 Tests 76 Pass Test 0 Fail IN ACCORDANCE YVITH. "W CRITMAOF PROTOCOL PA.105,.THIS ROOF ASSEMBLY HAS PASSED THE STAT{C UPLIFT QUAUTY CONTROLTEST..TMS TAS 106 TEST HAS SEEMPERFGMMED IN FULL ACCORDANCE TO THE REQUIREMENTS OF DADECOUNTRY, WITH NO DEVIATIONS. THIS REPORT IS NOT GWANTEEO IN CASE OF CASE OF NATURALMSASTERS. THIS REPORT I IS NOT VAUO FOR INSURANCE CLAIMS. A-1 Engineering Inspection Services, Inc 7066 SW 44 Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 a 1 roofinspectionggmail.com LAB CERTIFICATION # 14-1215.04 01/27/15 PERMIT. # RS -9-14-2047 925 NE 98 ST MIAMI SHORES, FL. 33138 7066 SW 44th Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 T T cd T T T T T T T T T T T T T T T T T T T T T T T T TrT T T T T T T T T T T T T T fi � ,,, 7066 SW 44th Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 02-02-15;10:29AM;From:Gulfeagle Supply FEB 0 $, 2015 RE: Permit#CZE .2 - (-�() � To:3052218506 ;3057409500 # 1/ 1 Miami shores Village INSPECTION AFFIDAW Building 136pertment 10060 N.UM Avoun Miami Shores, Florida 33138 Tal: (305) 796.2204 Fax: (305) 756.8972 DATE: r " 2P ` ! '511 I — I%VR !IV - cJR1 � licerroed as o (n) Con r i Engkieer / ArchkeCt, (P"=»9W**LW=T p.) FS 488 Building Inspector t.icense #: _c C., C o S 4 14 on or about M �!T t 1-4 C Oy'- ( I did personally ir►spect the wf deck mom and ire a Ymo) eco dr ,water barriermA at flz s c— i q ST k'kk kt S it Based upon that Oxitaft I have detem*ed the installation was done according to the Hurricane Mitigation Retrofit Manual (9ased on 553.K44 RS) Signature State of Florida Courrly of Dade: The underslgred, being the first duly sworn, deposes and says OW heMw is the contractor for the above property mentioned. Sworn to and subscribed before me this C�?-_ of re o / S / ftA- JO A Notary Public Sate of Florida at large 717' 3 i1 "sr�ctMr "(iM0fe1. BuAd41p, �Sldendsl, a R004nq OOIIp�clNd1. kltliMdINIClItlIIEd Wldor lAl FA. fa Mk9 Z&An espe jW ft*jjl01al liphe DINO OW Gf NC I dvft �IkA�Bnd�dd(l��d@OA�t�10YM1�NA(EdORNk pg1Yq�6C�011 ReNMN SMIZ09 A� ,p►°° CERTIFICATE OF LIABILITY INSURANCE ATE D01/08/2015 ) 0 I/08t2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE BOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE GERTWICATE HOLDER. IMPORTANT. If the certificate holder is an AMTIONAL INSURED, the policy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the POW certain require an endorsement. A statement on this certificate does not confer rights to the Certificate holder in 5eu ofsuch s . PRODUCER (305)41$-8411 (305)41$8413 Westward Insurance Services, Inc 2500 NW 79th Avenue Suite 203 [}tel FL 33322INSURER cNA**TEAcTMavIinPerez Ey 305 41§4411 _ , r�, : 305 418-8413 ADS ss: WaStward ns@!jeilsauth.net "Y NAS s A AgCtdent Insurance comoany Inc111573 INSURED Building Unlimited, Inc 247 SW $ ST Miami, FL 33130 INSURER s. ProOressive E-xDress :Insurance Comp@ny 124252 INSURER C; Lion InsW nCB Company INSURER D ; INSURER E INSURER F THIS IS TO CERTIFY THAT THE 'POLICIES OF INSURANCE LISTED BELOW HAVE SEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, 'TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WATH RESPECT TO'1 WICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES OF -SCRIBED HEREIN IS SUMCT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ODL m_ TYPE Or INSURANCE POLICY NUMBER � POUCY Erb LIMITS GENERAL.. uAettm ' a EACH OCCURR E A 711, IDAMAGE COMMERCIAL GENERAL L.Oa ITY i TO-FERTW— PREM Ma $ 1 N 3 "CLAIMs-MADE ' �% OCCUR I CPP0011249 00 i ; �S _I 1 O'lt##41eois j 01104=16 i MEDEXPtanr«ftl $ PERSONAL & ADV INJURY $1000.000 NERAL AGGREGATE ¢tet 5 2.000 000 GENLAGGREGATELIMITAPPUESPER: = PRODUCTS -COMPIOPAGG ` $ 1 000 000 v — T — I I 1 1 PRO• a LOC V POLICY' i ... 's AUTOMOBILE UAWTY ; t I I UMiT ANY AUTO f �MLBODILY NAM (Per esn) $ -----i OWNEDALL S rxLDB 02103035-1 L i 030It2014 0302015LY RUJRY (per amwou) $ HkREDaUTOS AUTOS { { 5 PROPERTY OAAAAGE $ ft S UMSRaLA LIAR OCCUR { i EACtf OOCURR NCE $ EXCESS UAB CLAIMS-MADEI 9 AGGREGATE r DED ! r RETEM*N$ , g r S WORKERS COMPENSATION ANDEMPLOYER& UASLITYYIN f VVC $TaT(6 LOTH j ; 01101/2015,1 01X01/2016 ANY PROPRIETORPARTNERIEXECUT>SIE } C' OFFiCEROIEMRER EXCLUDED? t i N ra ( I WC71949 ? I El. EACH ACCIMNT S � Q(}Q (Marmist"y in NII) i i El. DISEASE - EA EMPLOY_____FA$1.000.0W tt yyas. deso" urxw DESCRIPTION OF OPERATIONS bekrm E L DISEASE - POUCY LIMB 1$1000,000 1 t J DE&CRIPTION DF OFERATKM I LOCATION$ t VEWXLES (Aftt ACORP IM, Remarks Schedule, ifcrones a is t*W.* d) Building Contractor, Certificate Holder Is Usted as Additional Insured: t"_Ff2TtClt"_ATF BLit nFR t_AN11911 I ATnu Miami Shores Village Bldg [Sept 30050 NE 2nd Ave SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EMRATIfN�I DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE NTH THE POLICY PROVJBIDNS Miami Shores, FL 33138 AUTHORIZED RfPRELTATiVE f Maylin Perez Q 111tWiMIt) At;UKU [:cxFc DURATION. All AgTft aservgd. ACORD 25 (201OMS) The ACORD name and logo are registered marks of ACORD' Miami Shores Village Building Department SEP 192014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 201 C BUILDING Master Permit NO.Z F ) L- - 90 �-4 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC N ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ®PLUMBING []MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF [:]CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 925 NE 98 ST City: Miami Shores County: Miami Dade Zip: Folio/Parcel#:11-3206-014-3430 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder).— ���� OGi�Ou'► - tet c� 1<�►cc�v-, Phone#: � 6 '.�4 Address: q Z,!;- n C Rgio- 'ST- City: rCity: m i OLA Y i 1,S1,9W-e--% State: r Zip: 31 3 " Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Building Unlimited, Inc. Address: 247 SW 8 ST, # 188 Phone#: 305 751-2342 City: Miami State: FL Zip: 33130 Qualifier Name: Martin Curi Phone#: 305 751-2342 State Certification or Registration #: CCC 057977 Certificate of Competency #: DESIGNER: Architect/Engineer: N/A Phone#: Address: City: State: Zip: Value of Work for this Permit: $ 21,600 Square/Linear Footage of Work: _ 3G 5•?2 Type of Work: ® Addition 0 Alteration ® New ® Repair/Replace ❑ Demolition Description of Work: Re -Roof Tile and Flat Boral Concrete Flat Roof Tile Saxony 900 Slate Color: White Specify color of color thru tile: " 1-T— Submittal Fee $ C__5 �iC�D Permit Fee $ CCF $ t 3 0 CO/CC $ �5V -03 t' ray r_y. Scanning Fee $7 Radon Fee $ �l DBPR $ `" ` �-f Notary $ ®Z Technology Fee $ ( (-0Q Training/Education Fee $ ``i 0 Double Fee $ Structural Reviews $ Bond $Ci\J TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER°S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER; YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT"' Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. in the absence of suc posted notice, the inspection will nqt be approved and a reinspection fee will be charged. Signature i'1 o �/�- 1— OWNER or AGENT The foregoing instrument was acknowledged before me this 'Z day of J'S -7 , 20 by -TON WC.Fu-F-twho is personally known to me or who has produced 1�—AV6. as identification and who did take an oath. Signature The foregoing instrurrFent was acknowledged before me this _Ze7 day of _fes �' 1 , 20 _14 , by Gtr' , who is personally known to me or who has produced T u`1 40V as identification and who did take an oath. NOTARY PUBLIC: yilti ���, wi%�p��' , NOTARY PUBLIC: Sign: = Sign: MARIA LAURA SANCHEZ a e MY COMMISSION # eE88 Print: nn Print: F` ° •. •. °N' Sea{: % ,A I u . "ytiy Seal: �orj "�9` 0163 SMVICAcom eFF *************************** ** **** *********************************************************************** APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 CONTRACTORS' REGISTRATION ALL CONTRACTORS MUST PROVIDE COPIES OF LICENCES AND INSURANCES EACH TIME A PERMIT IS SUBMITTED. IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR: A. COPY OF QUALIFIER'S STATE LICENCES B. COPY OF LOCAL BUSINESS TAX RECEIPT C. COPY OF LIABILITY INSURANCE* D. COPY OF WORKERS COMPENSATION INSURANCE* IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY: A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER B. COPY OF LOCAL BUSINESS TAX RECEIPT B. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL CONTRACTOR'S TAX RECEIPT. C. COPY OF LIABILITY INSURACE* D. COPY OF WORKERS COMPENSATION INSURANCE* *YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW: Certificate Holder: MIAMI SHORES VILLAGE BLDG DEPT 10050 NE 2ND AVE MIAMI SHORES, FL 33138 Certificate must specify the description of operations or contractor license number. BUSINESS NAME: BUSINESS ADDRESS: -,74-1 '-5u-) --R-- LCM-2 CITY M tAti-t� STATE --VC._ ZIP CODE 33« BUSINESS PHONE: FAX NUMBER CELL PHONE (_''_) QUALIFIER'S NAME:T"t QUALIFIER'S LIC NUMBER: GG-�- <f:)S; -I3-1. STATE OF FLORIDADEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATIONCONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-13951940 NORTH MONROE STREETTALLAHASSEE FL 32399-0783 CURI, MARTIN BUILDING UNLIMITED INC 247 SW 8 ST #188 ------ -- Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects lo yactvt brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our -services, please log onto www.myfloridallcense-corn. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Flodda. and congratulations on your new license! ' DETACH HERE KEN LAWSON, SECRETARY OF FLORIDA S AND PROFESSIONAL REGIULATION RANCEDATE CERTIFICATE OF LIABILITY INSU1 0-9/0812014 THIS CERTIFICATE IS ISSUED ASA BATTER OF INFORMATION ONLY AND CONFERS N0 Rom UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAQE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES MOT CONSTITUTE A CONTRACT BETWIMN THE MUiNG tNSURER{S}, AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: III the certlftc a holder Is an ZiNT10NAL 1NSt o, the potkWiss) moat be endoresd. M SUBROGATION 13 WAIVED, sutjeet to the term and conditions of the iwlicy, certain may rs pft an endorsenwrit. A statarnent on this ceR (tate does not cttnier rights to t#re certificate holler in lieu of such PRODUCER (305)418-8411 (305) 418-84f3- Westward Insurance Services, Inc 2500 NW 79th Avenue wAk€: P y1in Perez Pf"IONNE ,. (305) 418-"11 (305)4%8411 €SSS, westwatdlns %Ilst th.net Suite 283 cc1tAI Dora! FL 33122------_,.._. _ _ INSURED Building Unlimited, Inc 247 SW 8 ST Miami, FL 33130 NAS r � U RA;Accld t Insurarm Goal n' Inc 141 73 L"YRER s J Prc�clressive Egress- QgmpanY -,'242R_ INSURER C: usn_: j FNSUiERE: INSURER F; 9 wom Lai # ern Ew om om v, ,l $ 5 - n V-V1Qq%M MA1110r THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE SEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. _. LL A _ iS_ LM i TYPE OF INSURANCE ( LICY>F Pi3Y NUMBER PAY Eiti� LIMITS GENERAL LIABILITY i EACH OCCURRENCE I A COMMERCIAL GENERAL L"UTYLU CLAIMS -MADE i' OCCUR CP'pool 1249 00 4 01/0412014 01/0412015 9 wom Lai # ern Ew om om v, ,l $ 5 PERSONAL & AW P&JURY S 1 OQ s I GENERALAGGREGATE 3, W1 GEN'L AGGREGATE LIMIT APPLIES PER, + : 1 POLICY i PRO f PRODUCTS - CCM PIOP AGG s i nAn 0n $ v/ LOC AUTOMOBILE L"KjTY LIMIT __. 1 I BODILY INJURY iPW pww) S ANY AUTO OWNED ��� SCHEDULED B �µ i ° LY INMY (Peri $ ALL AUTOS 02103(I3 }-1 ; 03/07M14' / } NDN 03107/2D15 i -OWNED Y HIRED AUTOS jf AUTOS I IiOPERTY DN4MACaE a UMBRELLA UAB OCCUR € i EXCESS LIAR AIMS CMADE �� I� EACHOCCURRENCE E AGGREGATE $ DED RETENTION{ $ WORKERS COMPENSATION E YIN % 0110&M14 AANYI ROPR�tE 01(t1B12015 STATU i OTy FPARL TINIEW€XECL}'I'IVE �. C. ICCEE� NHj EXCLUDED? (NIA WC20140000C? � EL EACH ACCIDENT - $1,000, I E.L.DISEASE -EAEMPLOYEE S (){}Q in (MePi yyeess desatbeurWer DESCRIPT€ON OPERATIONS below a E.L.E +POLICY LIMrf $ 1 r � 1 DESCRIPTION OFOpERATiOMS I "OC^TI N s i vE {A#ach-AC(m lol, At wum RW"*s Sche& tee g er"e spue i. isqt*w4 : Building Contractor, Certificate Halder is Listed as Additional Insured, r-=0slCII%A7c LJf%l e%so I It m Miami Shores Village Bldg Dept SHOULD ANY OFTit€ ABOVE OESC JVD pOUCIES 10 CANCELLM mo i& 10050 NE 2nd Ave THE €XPft`nO i DATE THEREOF, NOTE WILL BE DEUVERED IN Miami Shores, FL 33138 ACCORDANCE WITH THE POLICY PROVISIONS, AUnfORIZED REPRESENTATIVE' Maylin Perez 01988-2010 ACORD CORPOR&OKAll rights ACORD 25 (2010105) The ACORD narne and logo are registered mance of ACORD MIA,MF t 4171963 DBA/BUSINESS NAME: BUILDING UNLIMITED INC BUSINESS LOCATION: 12170 SW 128 CT 101 MIAMI, FL 33186 OWNER/CORR BUILDING UNLIMITED INC PHONE # 305-609-5763 247 SW 8 ST #188 MIAMI, FL 33130 NAICS CODE: 238990 MIAMI-DADE COUNTY - STATE OF FLORIDA N/A October 14, 2014 LOCAL BUSINESS TAX RENEWAL 2014 -2015 APPLICATION RECEIPT: 3725331 STATE # CCCO57374 BUS. COMMENCEMENT DATE: 01/01/1995 SEC TYPE OF BUSINESS BLDGS SPECIALTY BUILDING CONTRACTOR If no longer in business, please notify us in writing. Review and correct the information shown on this application. A 25% penalty will be assessed to anyone found operating without a paid local business tax, in addition to any other penalty provided by law or ordinance (Sec 8A-176(2)). A Certificate of Use and/or City Business Tax Receipt may also be required. MIAMI-DADE COUNTY - STATE OF FLORIDA LOCAL BUSINESS TAX 2014 - 2015 APPLICATION 4171963 BUSINESS LOCATION: 12170 SW 128 CT 101 MIAMI, FL 33186 OWNER/CORR BUILDING UNLIMITED INC BUILDING UNLIMITED INC MARTIN CURI PRES 247 SW 8 ST #188 MIAMI, FL 33130 FEE AMOUNT Receipt Fee 30.00 UMSA Fee 30.00 Beacon Council Fee 15.00 Bingo Permit Fee 0.00 Nightclub Permit Fee 0.00 Multi -Municipal Contractor Fee 0.00 Restricted Contractor Fee 0.00 Library Fee 0.00 Transfer Fee 0.00.. Doing Business without a License Penalty 0.00 Late Penalty 0.00 Collection Cost 0.00 NSF Fee 0.00 Prior Years Due 0.00 Amount Recently Paid - 75.00 To pay online go to www.miamidade.uov/taxcollector To pay by mail, make check payable to: Miami -Dade County Tax Collector Business Tax 200 NW 2nd Avenue Miami FL 33128 To pay in person go to: 200 NW 2nd Avenue (305) 270-4949, fax (305) 372-6368 A service fee of not less than $25.00 up to a minimum of 5% will be charged for all returned checks. + RETAIN FOR YOUR RECORDS + + DETACH HERE AND RETURN THIS PORTION WITH YOUR PAYMENT N/A October 14, 2014 RENEWAL RECEIPT. 3725331 STATE #CCC057374 BUS. COMMENCEMENT DATE: 01/01/1995 SEC TYPE OF BUSINESS BLDGS SPECIALTY BUILDING CONTRACTOR 1 APPLICATION IS HEREBY MADE FOR A LOCAL BUSINESS TAX RECEIPT OR PERMIT FOR THE BUSINESS PROFESSION OR OCCUPATION DESCRIBED HEREON. I HAVE BEEN INFORMED OF ALL ZONING RESTRICTIONS IMPOSED ON THIS RECEIPT. I SWEAR THAT THE INFORMATION IS TRUE AND CORRECT. SIGNATURE REQUIRED SEE INSTRUCTIONS ABOVE Please pay only one amount. The amounts due after Sept 30th include penalties per FS 205.053. if Received By Oct 31, 2014 Nov 30, 2014 Dec 31, 2014 Jan 31, 2015 Please Pay $0.00 $0.00 $0.00 $0.00 7000000000000000000000003725331201500000007500000000000001 Pomp Wall .ilabk Duk MIAMFDIAL)E Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application 1Xm . __e "Delivering Excellence Every Day" OCT 0 9 2014 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, B :. Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. A 4- Concrete wall Bastomeric sealant tooted to facilitate water run-off Ontional: compressible Elastomeric sealant Metal counterflashiing meth. attached 8" o/c wl washer I Parapet wall height: Seal top of base flashing w/ comptable material Termination bar mech. attached 6" o/c Field plies turned up wall Base flashing min. 8" above finished roof ►-♦Top Ply Inter, lies Base SheW, *#aa• a##st I CITY Roof Mean Height: Base Flashing: 1 ft. 10 ft. Ruberoid Mop Surfacing: : • • • : • -N/A- ...... .... .. Top Ply: ...:.. Mineral Su7ace04A-6hee*:0 0 • Inter Ply Sheer: ••; :.••. ••••• Ruberoid 20 . •....0 • Base Sheet: :0.0:0 ; .. .... . GAFGLAS #75 ' • ' :"' Roof Deck Type: 5/8" Plywood } Pie: This diagram contains sept lengths (rounded to the been removed for readability. Plus signs prefaoe some n Shs &%vffwM t5 Wov un U �eaawwft Report: W82308 dw� s OMTWW Building tkdimited, It c __ _ c•py�W ® zoos--2914IE U?#e s; 8,145,WW, #,T nearest whole number) over 5'feet. In some cases, segment labels harms umbers to avoid confusion when rotated (e.g. +6 and +9) i j s f i •• • •••i •• ••• • • :S • • • re • { • •• S 3 W nearest whole number) over 5'feet. In some cases, segment labels harms umbers to avoid confusion when rotated (e.g. +6 and +9) Section A MIAM12 Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section A (General Information) Master Permit No: Process No: Contractor's Name: Building Unlimited, Inc. Job Address: 925 NE 98 ST Roof Category 0 Low Slope ❑ Mechanically Fastened Tile✓❑ Mortar/Adhesive Set Tile Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Roof Type ❑ New Roof ID Re -Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes n✓. No If yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area (ft.2) 773 Steep Sloped area (ft.a) 2880 Tota (ft.2) 3653 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): 3 Corner Size (a' x a'): 3 x 3 C"ITY , SSP 1 g 2414 COPY See Attached Miami Shores Villa e APPROVED DATE ZONING DEPT BLDG DEPT SUBJECT 1"0 CChIPt.)A,NCE WITH ALL STATE ANL) C CIiNiY 3ULLS AND REGU E TIONS SECTION 1524 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section.. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. 1. Aesthetic*-W6*=nship The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) issues are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 71.1. 2, Renalling Wood Docks, When replacing roofing, the existing wood roof deck may have to be renalled in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). T` 1. 3, Common Roofs; Common mofa are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposetl Ceilings, Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The Florida Building Code provides the option of maintaining this appearance. T( -. Fancling 4lfeter, the currrent rcaof system and/or deck of the building may riot drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. dive ow scup (wall outlets): It is required that rai+r�water flow oft so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the Florida Building Cale, Plumbing. JT. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the s ructural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be bengficial to consider additional venting which can result in extending the service life of the roof. , ant's Signature Property Address ..!!;7/ P� / V4 Date Permit Number Rev_ 9/20/2005, Computer services, Building Department Miami shares Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'$ AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION $83.844 F.S. To., Miami Shores Village Building Department Date; 10060 NE 2fw Ave . Miami Shore, FI 33138 (..._ eke - i�cl-n 6 0-) L'( 2— 1 i• V--' Property Address, 925 NE 98 ST, Miami Shores, FL 33138` Roofing Permit Number: Dear i i Official: rat 4 �• that r required to retrofitroot i well connectionsof building be1+ JI—11— r i ii i ct valorem taxation. a The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions J�na 1894 edition of the South Flori7BuPdIngode(1994 S—FBC)—� . Print Name The undersigned, being the fast duly sworn, dues and says that he/she gwner for the above pmpeq mentioned. Sworn to and subscribed before me this day of '. P Notary Public, Sate of Florida at Large • WA�ett � �tta�n ertr� � ft�r t�P�$ of ad Petr► � et�al to � QQ ;mi _ ti g �s nates npr a l�84 $FK Tim t r _ a Ciawt tt i #�e Rt kc tR �� on KIM Property Search Application - Miami -Dade County Page 1 of 5 Detailed Report Property Infomration Folio: 11-3206-014-3430 Property Address: 925 NE 98 ST < Owner TONI LOCKHART SAYDKHUZHIN Mailing Address 925 NE 98 ST MIAMI, FL 33138 Primary Zone 1100 SGL FAMILY - 2301-2500 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY. 1 UNIT Beds f Baths I Half 2/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq.Ft Adjusted Area 2,999 Sq.Ft Lot Size 15,450 Sq.Ft Year Built 1946 Assessment Information Benefit Type 2014 Year 2014 2013 2012 Land Value $262,486 $210,250 $166,894 Building Value $225,360 $227,054 $257,464 XF Value $13,353 $13,388 $16,726 Market Value $501,199 $450,692 $441,084 Assessed Value $455,310 $448,582 $441,084 Benefits Information Benefit Type 2014 2013 2012 Save Our Homes Cap Assessment Reduction 889 $2,110 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Generated On: 8/2/2014 Taxable Value Information 2014 2013 2012 County - - Exemption Value $50,000 $50,000 $50,000 Taxable Valu School Board $405,310 $398,582 $391,084 Exemption Value $25,000 $25,000 $25,000 Taxable Value 1 City $430,310 $423,582 $416,084 Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $405,310 $398,582 $391,084 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Valu $405,310 $398,582 $391,084 The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not refleet the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/lwww.miamidade.gov/inib/disdaimier.asp (http:/ www.miamidade.govinfbidisdairrer.asp) Version: http://www.miamidade.gov/propertysearch/index.html 8/2/2014 ■I E N S W -+f-5 x .4Y-5-It"A-) This diagram contains segment lengths (rounded to the nearest whole number) over 5 feet. In some cases, segment labeb haw been removed for readability. flus signs prefiam some numbers to avoid confusion when rotated (e.g. +5 and +9). lbs datwnent k Dtdlded-oft L""e w Fagt V*W TachncCj,M to thesequeAw for their tr$ernal LK- 0* satged m the tem and rwomoas pfftm y agreed to by M Report: 9 i$23f)$ r , MOO" Nr Use W €a*Vv 7�tnr nom, n rune the nr rra faOeva w rahnabcOes ana"Wbe reppdaCeda d dub*k ted mtv waidn therequesmes cwWaW. Any reproductm. a, dvrft tan to arryme mWde, of Me rftp 's company •rldaud fag6e°l**A prj,,, wften pmWss_ S sUrctty pre died. M Rets and handh"g of th5 revert are snhd to the Ten aad COWWOns WeWW* agreed to by the "estor,. so— L:47t4 W Wf:U-%PFJ NOS. Page 4 W'dm9• Section D MIAMMI Miami -Dade County Building Department Electronic Application t High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section D (Steep Sloped Roof System) Roof System Manufacturer: I Boral Roofing, LLC Product Approval Number (NOA): 12-0222.03 Minimum Design Wind Pressures, (from RAS 127 or Calculations): P(1): 39.1 psf P(2): psf P(3): 100.7 psf Maximum Design Wind Pressures, (From the NOA Specific system): 40.4 psf Sloped System Description Fill in the specific roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: 3 11/12" Roof Mean Height: 18 ft. Roof Perimeter Width: 3 ft. Optional Ridge Ventilation: n/a Method of Tile Attachment: —Adhesive, Medium Patty Polyfoam Polypro AH 160 -- Alternate Tile Attachment Method: n/a Clip or Screw Spacing for Metal Roof Panel Attachment: Field: El " o/c Perimeters: El " o/c Corners: n/a " o/c Number of Screws Required Per Clip: Screw Type, Size, & Gauge for Metal Roof Panel Attachment: Na Cedar Wood Shingle/Shakes: Length: Na in. Maximum Exposure: Na in. Number of Fasteners & Type for Shake/Shingle Attachment: n/a Deck Type: —5/8" Plywood— Alternate Deck Type: Na Insulation Board: Na Fire Barrier. Na Underlayment Type: 30# ASTM D22611 Optional Nailable Substrate: Na Fasteners: Na Cap Sheet Type: Polyglass TU Plus Cap Sheet Adhesive / Bonding Material: Self Adhere Roof Covering: Flat Concrete Tile Roof Covering Attachment Method: Polyfoam Interlayment Sheet Type: Na Drip Edge Size & Gauge: -3" face 26 ga. - Drip Edge Material Type: —Galvanized Metal— Drip Edge Fastener Type: 11/4" R/S NAILS @ 4" O/C Hook Strip/Cleat Gauge or Weight: —Na— fileW/CVDocuments51o20and%20Settings/sky/Desktop/rooi°i°20permit%20fcems/section d 3.htm9/13/2007 10:11:01 AM Section E 2 MIAMN in Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day' Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based file systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: 39.1 X 0.313 = 12.24 - Mg: 8.03 = Mr1: 4.21 :5 40.4 NOA Mf P 2: 68.1 X 0.313 = 21.32 - Mg: 8.03 = Mr2: 13.29 < 40.4 NOA Mf P 3: 100.7 x I0.313 _ - W. = 31.52 - Mg: 18.03 1 = Mr3: 23.49 5 40.4 NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127' For Uplift based file systems use Method 3. Compare the values for F' with the values for Fr. If the P values are greater than or equal to the Fr values, for each area of the roof, then the file attachment method is acceptable. P1: x I: Symbol _ x w: Design Pressure _ - W.. Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. = x Cos B: = Fr1: < NOA F' P2: x is 8 x W. Aerodynamic Multiplier _ - W. Product Approval (NOA) - x Cos @: = Fr2: 5 NOA F' P3: x l: Product Approval (NOA) = x w: Mr _ - W. Minimum Attachment Resistance = x Cos 0: = Fra: <_ NOA P Where to Obtain Information to complete tile calculations Description Symbol Where to Find Design Pressure P1 or P2 or P3 Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 8 Job Site Aerodynamic Multiplier X Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) Tile Dimensions I = length w = width Product Approval (NOA) P41AMI- MIAMI-DARE COUNTY �i�i�Y� PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.goviDera Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Saxony 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA#07-0711.03 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of 8 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete Deck Type: Wood 1. SCOPE This NOA approves a system using Saxony 900 (Shake, Slate & Split Shake) Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Test Identifier Test Product Applicant Dimensions Specifications Description Saxony 900 1= 17" TAS 112 Flat profile, interlocking, high - Appendix III w = 13" pressure extruded concrete roof tile The Center for Applied 1-5/32" thick Slate equipped with two nail holes. For May 1994 1-9/32" thick Shake & direct deck or battened nail -on, mortar TAS 101 (Mortar Set) Split Shake set or adhesive set applications. Trim Pieces Length: varies TAS -112 Accessory trim, boosted Barcelona, Engineering, Inc. Width: varies concrete roof pieces for use at hips, varying thickness rakes, ridges and valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL. 2.2 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 94-060A Static Uplift Testing March, 1994 Engineering, Inc. TAS 101 (Adhesive Set) NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 2 of 8 The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies The Center for Applied Engineering, Inc. Atlanta Testing & Engineering, Inc. Celotex Corporation Testing Service Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 25-7183-6 25-7183-5 25-7214-1 25-7214-5 7161-03 Appendix II Letter Dated Aug. 1, 1994 P0631-01 P0402 Project No. 307025 Test #MDC -77 R1.894 R2.894 R3.894 520109-1 520111-4 520191-1 Evaluation Calculations Evaluation Calculations Evaluation Calculations Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (2 Quik -Drive Screws, Battens) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Direct Deck) Static Uplift Testing TAS 102 (1 Quik -Drive Screw, Battens) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Wind Driven Rain TAS 100 Physical Properties TAS 112 Static Uplift Testing TAS 101 Static Uplift Testing TAS 101 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Feb. 1995 Feb. 1995 March, 1995 March, 1995 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 Oct. 1994 Aug. 1994 Dec. 1998 March 1999 February 1996 April 1996 December 1996 NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 3 of 8 Walker Engineering, Inc. Evaluation 25-7183 March 1995 Width -w (ft) Calculations 11.5 1.417 Walker Engineering, Inc. Evaluation Aerodynamic Multipliers January 2007 Calculations Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 130 TAS 112 January 2007 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Saxony 900 (Slate, Shake & Split Shake) Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (i x w) Tile Profile Weight -W (lbf) Length -I (ft) Width -w (ft) Saxony 900 Slate, Shake & Split Shake 11.5 1.417 1.08 Table 2: Aerodynamic Multipliers -X (ft) Tile ;L (ft) x (ft3) Profile Batten Application Direct Deck Application MonierLifetile Saxony 900 0.289 0.313 Slate, Shake & Split Shake NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 4 of 8 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" n12" or Profile 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 greater Saxony Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct 900 24.3 Deck 24.2 Deck 19.0 Deck 22.1 Deck 35.5 Deck 34.8 Deck Slate, 7.16 8.12 7.08 8.03 6.97 7.91 6.82 7.74 6.65 7.55 6.46 7.34 Shake & Split Shake Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (mina 19/32" plywood) Battens Saxony 900 Slate, Shake & Split Shake 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 1 48 Screw 30.8 30.8 18.2 2 48 Screws 51.7 51.7 24.4 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Monierl-ifetile Saxony 900 Adhesive 31.3 Slate, Shake & Split Shake 1 See manufactures component approval for installation requirements. 2 Dow Chemical TileBond Average weight per patty 13.9 grams. Polyfoam Product, Inc. Average weight per patty 8 grams. NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 5 of 8 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Monierl-ifetile Saxony 900 Slate, Shake & Split Shake Polyfoam PolyProTm 118.9 Polyfoam Pol ProT" 40.4 3 Large paddy placement of 45 grams of Po! ProT"'. Mortar Set 4 Medium paddy placement of 24 grams of Pol ProTm. Slate, Shake & Split Shake Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Monierl-ifetile Saxony 900 Mortar Set 43.9 Slate, Shake & Split Shake 5. Tile-Tite Roof Tile Mortar 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR SAXONY 900 TILE (LAKE WALES FL PLANT LOCATED UNDERNEATH TILE 6. BUILDING PERMIT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 6 of 8 NAIL } PROFILE DRAWING WATERLOCK SAXONY 900 CONCRETE ROOF TILE (SLATE MODEL 5/32 " (slate) 9132 A (shake) OR (ERLAY MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SPLIT SHAKE MODEL MIAMbW1DE CNOA No.: 12-0222.03 OUNTY ... f, Expiration Dote: 04/26/17 Approval Date: 04/19/12 Page 7 of 8 MONIERLIFETILE SAXONY 900 CONCRETE ROOF TILE (SHAKE MODEL END OF THIS ACCEPTANCE NOA No.: 12-0222.03 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 8 of 8 MIAMI -DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) Aww.miamioade.govieconom� Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Cateeorv: Roofing Sub-Cateeory: Underlayment Material: SBS , APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'3-3/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'V/8" 3/$" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 65'8" x 3'32/.99 waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick IR -Xe Roll: TAS 103 and A fine granular/sand top surface self -adhering, underlayment 65' x 3'3218" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32'10" x 3'321s" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Pius Roll: TAS 103 and A rubberized asphalt self -adhering, glass- underlayment 65' x 3'3-3/$" ASTM D 1970 fiber/polyester reinforced waterproofing (Surface Printing) 80 mils thick membrane. Designed as a metal roofing and roof Manufacturing Location the underlayment. #1 & #2 Polystick TU P Roll: TAS 103 and A rubberized asphalt waterproofing membrane, underlayment 32'10" x 3'321s" ASTM D 1970 glass-fiber/polyester reinforced, with a granular Manufacturing Location 130 mils thick surface designed for use as a tile roof #2 underlayment. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'3-3/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'V/8" 3/$" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self -adhering, polyester Manufacturing Location 65'8" x 3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed #2 60 mils thick as a a roof tile underlayment. MANUFACTURING PLANTS: 1.Hazelton, PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08 -R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-1 TAS 103 & TAS 110 08/06/12 P40390.08.12-2 ASTM D 1623 08/07/12 P40390.10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PRI01111 ASTM D 4977 04/08/02 PUSA-005-02-01 ASTM D 4977 01/31/02 PUSA-018-02-01 ASTM D 2523 07/14/03 PUSA-035-02-01 TAS 103 09/29/06 PUSA-033-02-01 ASTM D 1970 01/12/06 PUSA-055-02-02 TAS 103 12/10/07 PUSA-083-02-01 TAS 103 06/30/08 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX201-17A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX2313813 TAS 103/ASTM D4798 & G155 02/18/10 DX23138A TAS 103/ASTM D4798 & G155 02/18/10 NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self -adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3-1/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 12-0713.02 ___LAP; 3 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof file systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) MTS 11R -Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven, FL. 180 180 180 180 180 180 180 90 Hazelton, PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof the manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof file applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof file applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) file assemblies shall be as follows: (See Table Below) Tile Profile Polystick MTS Polystick 1R -Xe Polystick TU, TU Polystick TU Plus, TU P, Tile Max Pro Flat Tile Prohibited without 5:12 No limitation No limitation battens Profiled Tile Prohibited without Prohibited No limitation No limitation battens The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. Mu►MFo�aoe courir�r NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. d CL 0 ca M r m 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAM14DAM COUNTY BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. NOA No.: 12-0713.02 Expiration Date: 04/13/16 Approval Date: 02/14/13 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELMES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading the on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the the manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that water will run parallel to or over the top of all laps of the patch. 10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 12-0713.02 APPROVED MIAMFOIADE COUNTY Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 8 MIAMI -DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 12-0228.18 and consists of pages 1 through 11. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-0502.02 MU4M4UADE COU Expiration Date: 05/10/17 APPROVED Approval Date: 12/12/13 Page 1 of 11 ROOFING COMPONENT APPRovAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2 -Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH - 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Pro Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft 3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Fe 3.1 Perm / Inch +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @I 58T., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. APPROVED NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Reyort Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 Trinity Engineering 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 ASTM D 1623 04/18/12 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMFDADE COUNTY ...e , 11� 3. 3NC 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 4. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 5. Roof Tile manufactures acquiring acceptance for the use of 3M7 2 -Component Foam Roof Tile Adhesive AH - 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 6. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No.: 13-0502.02 WILUMOTIAMMIAMFDADE COUNTY Ex iration Date: 05/10/17 ,I 1 Approval Date: 12/12/13 Page 3 of 11 INSTALLATION: 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3M7M 2 -Component Foam Roof Tile Adhesive AH -160. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B)• 6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 4 of 11 Table 1: Adhesive PIacement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All 3M"2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. APPROV�6 NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Doable Pan Tile 1. Starting at the eave course, apply a minimum T' (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the file being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 6 of 11 7 In. Nail through plastic cement (when required) in. Battens optional pPFR�VEDI ADHESIVE PLACEMENT DETAIL # 2 "dy(Beneathnia) Paddy (Beneath Eave Closure Fascia Flat/Low Profile Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the the closest to the overlock of the file being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) -12 (77.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 TU IlU Sm Pra1leTft L On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat file or under the pan portion of the tile for low or high profile file closest to the overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm2) of adhesive contact with the underside of the file 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x V (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 int (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date; 12/12/13 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm) - 11 (71 cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm) - 9 (58.1 cm) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NQA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 10 of 11 1) Place enough adhesive to achieve 65 to 701 In contact with the pan tie. 2) Tum cams upside down. Place adhesive In to 1 In, from outside edge of carer tile. Then Install the tie. Ensure 20 to-� 25 sq. tn. contact area. l Underiayment i (motar shown) Fascia ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pitch applications (when required) point -up Mortar on longitudinal edges of tie Remove top portion of the cave course cover tile. Abut to second course of pan ties. Ensure eave end of pats and cover tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support cave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover file over after foam is applied and place onto pan file course. Insure a minimum of 20 (129 cm) - 25 (161.3 cm) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 11 of 11 Section C Miami -Dade County Building Department Electronic Application M High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section C page (Low Slope Roof Systems) Fill In the specific roof assembly components. If a component is not required, insert not applicable (n1a) in the text box. MANUFACTURER: I GAF Material Corp. Top Ply: ROOF SYSTEM Product Approval (NOA): 13-0424.14 System Type: Mineral Surface Cap Sheet Top Ply Fastening / Bonding Material: Wind Uplift Pressures, From RAS 128 or Sealed Calculations: I Hot Asphalt (131) Field: -42.8 psf Surfacing: N/A (P2) Perimeters: -71.7 psf (P3) Comers: '108.7 psf Maximum Design Pressure From NOA: -52.5 psf Roof Slope: 0 .:12 Roof Mean Height: 12 it. Parapet Walls: 0 No 0 Yes Parapet wail Height: ft. Deck Type: 15/8" Plywood— Support Spacing: 24 1 " o1c Aitemate Deck Type: — N/A — Existing Roos: - N/A - Fire Barrier: — N/A — Vapor Barrier. — N/A — Anchor Sheet: — N/A.— Anchor Sheet Fastener/ Bonding Material: — N/A — Insulation Base Layer Size & Thickness: - N/A - Insulation Base Layer Fastener / Bonding Material: Hot Asphalt Insulation Top Layer Size & Thickness: — NIA — Insulation Top Layer Fastener / Bonding Material: —'N/A — Base Sheet(s) & No. of Ply(s): GAFGLAS #75 Base Sheet (1 Ply) Base Sheet Fastener/ Bondinq Material: 1 1/4" R.S. Nails Ruberoid 20 0 Pty) Ply Sheet Fastener / Bonding Material: Hot Asphalt SINGLE PLY MEMBRANE: Single Ply Manufacturer / Type: — N/A — Single Ply Sheet Width: N/A " 1/2 Sheet Width: N/A No. of Single Ply 1/2 sheets: NIA Single Ply Membrane Fastening / Bonding Material: — N/A — �✓ FASTENER SPACING FOR BASESHEET ATTACHMENT ❑ SINGLE PLY MEMBRANE ATTACHMENT 1. Field: El " o/c @ Laps &El rows ED - o/c 2. Perimeter:E] " o/c @ Laps & rows " o/c 3. Corner: 6 " o/c @ Laps &E] rows ED - o/c NUMBER OF FASTENERS PER INSULATION BOARD: 1. Field: EE 2. Perimeter. IE 3. Comer. N/A Insulation Fastener Type: — N/A -- WOOD NAILER TYPE AND SIZE: — N/A — Wood Nailer Fastener Type and Spacing: — N/A —. EDGE & COPING METAL SIZES: Edge Metal Material [—Galvanized Metal— Edge Size: —3" face 26 ga — Hook Strip Size: —METAL EDGE HOOK STRIP N/A— Edge Metal Attachment: (— N/A —. Coping Material: I —PARAPET COPING METAL N/A— Coping Size: —COPING METAL SIZE N/A— Hook Strip Size: --COPING METAL HOOK STRIP N/A— Parapet Coping Metal Attachment: — N/A — Edge Nailable Deck MIAM Emm "Delivering Excellence Every Day" Miami -Dade County Building Department EIectronic Application High Velocity Hurricane Zone Roofing Permit Application Form Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. Top Ply Interplies Base Sheet Roof Mean Height: 2 ft. Drip Metal: E3Face 26 ga. Surfacing: —a— Drip Metal F-N/A- Top Ply: FGAFGLAS Mineral Surface Cap Sheet Interplies: Y s Ruberoid 20 Y - Base Sheet: Roof Deck GAFGLAS #75 Deck Type: 5/8" Plywood DErARTMViT 'OF REGUATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION 1361 Alps Road Wayne, NJ 07470 materials. The documentation Product Control Section to be Having Jurisdiction (AHJ). MUMI-DADE COt)NW PRWVCTCONI' OLSEC71ON 11905 SW 26 Stott Room 209 Miami, FW" 33175-2474 T (796)315-2590 F (796) 31525- v ved and accepted by Miami -Dade County RER - ity and other areas where allowed by the Authority This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have tins product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdictiom RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product, Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. Dummom. : GAF Rubereie Modified Bitumen Roof System for Wood Declis LABELING*. Each unit shall bear a permanent label with the manufacturees name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENIMAL of this NOA shall be considered after a renewal application has been filed and them has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occurafter the expiration date or ifthere has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for Wes, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVFJtTISE*W,NT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature- If any portion of the NOA is displayed, then it shall be done in, its entirety. Nspwnom A copy of this entire NOA shall be provided to the user by the manufacturer or its distribitors and shall be available for inspection at the job she at the request of the Building Official. This NOA renews and revises NOA No. 09-0224.01 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. NOA Nea 13-0424.14 EXpirstion Date: 11184/14 Approval Date: IW1113 Page 1 of 29 Wmbrane Type: SBSISBS, Cold Applied Deck Type 1: Wood, Non -insulated DeckDeseription: 151,; or greater plywood or wood plank. decks System Type E(I): Base sheet mechanically fastened to roof deck Ali General and System Limitations shall apply. Fire Barrier: FireOut7 Fire Barrier Coating, VersaShield* Fire -Resistant Roof Deck (Optional) Protection or Securock* Gypsum -Fiber Roof Board, Basesbeet: GAFGLAS* #80 Ultima Tw Base Sheet, GAFGLAS* Stratavent! Eliminator"' Nailable Venting Base Sheet, Ruberoid* 20, Ruberoie SBS Heat -Weld"'" Smog or Ruberoie SBS Heat -Weld'" 25 base sheet mechanically fastened to deck as described below - Fastening GAFGLASO Ply 4, GAFGLAe FlexPly�" 6, GAFGLAS* #75 Base Sheet or any options.. of above base sheets attached to deck with approved annular ring shank naits and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in theIield. (Maxim De*n Pressure -45 psf, &e General Ll nitation #7) GAFGLASO Ply 4, GAFGLAe FlexPly T" 6, GAFGLAS4 #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec #12 Fastener, Drifl-TeC7 # 14 Fasteneror Drill-Tec7m XHD Fastener and Drill-Tec7 3- Steel Plate, Dri11. Tec ITec7 AccuTrac" Flat Plate or Drill -Tec- Ac Trace Recessed Plate:installed 12" o.c. in 3 tows. One row is in the 2" side lap. The other -rows are equally spaced approximately ir ox. in the field of the sheet. (Mazimunt Deign Fr ere -45 psf, See General Liniftation #7) GAFGLAe Flcxfly� 6, GAFGLAS* #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (MaximumDeskn Pressure -52.5 psf,,See General Lbabsilan #y} GAFGLAe #80 Ultirrur Base Sheet, Ruberoi(f 20, Ruberoid* Mop Smooth, base shed attached to deck with approved annular ring shank nails and tin caps at a fastener, spacing of 9" o.c. at the 4" lap staggered and in two rows 9" ox. in the field. (Maxim[ Des Pressure -60 psf, See Gener-al Lim#wkn #7) Drfll-TeC #12 Fastener, Drill -Tec'- # t4 Pas tier or Drill -Tee- XHD Fastener and Drill -Tec 3- Steel Plate, Drill -Tec"" AccuTrae Flat Plate or Drill-Tec:- AcciiTrae Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other tows are equally spaced approximately 9" o.c. in the field of the sheet (Maximum Design Pressure -60 psf, See General LlmUadon #7j lap staggered in two -rows 9" in the field. (Maxhnam Deskm Prmure -40 p4; &e General Unizoian #7) NOA Ne�:134424.14 Expiration Date: 11/%/14 Approval Date: 19131/13 Page 25 of 29 GAFGLAS:6 075 Base Sheet or any of above base sheets attached to deck with Drill -Tec * #€12 Fastener,:Drill-Tec"` #14 Fastener or Drill-Tcc7 XHD Fastener and Drill -1 W* 3" Steel Plate, Drill-Tec7 AccuTme Flat Plate or Drill-Tec7 AccuTrk' Recessed Plate installed r o.c. in 4 rows. One row is in the r side lap. The other rows are equally spaced approximately r o.c. in the field of the sheet. (Mxdmum Do** Newure —75 psf, See Geneml Limkafim Ply Sheet: (optional) One or more plies GAFGLAS* Ply 4, GAFGLAS* FlexPly'" 6, GA,FGLAe #80 Ultima Base Sheet, Ruberoid* Mop Smooth or Ruberoie 20 sheet adhered in a full mopping of approved asphalt applied within the EW range and at a rate of 2040 lbsJsq. Membrane- =or more plies of Ruberoie Mop Smoolth, Ruberoie Mop 170 FR, Ruberoie Mop Granule, RoofMatch"SBS Modified Granular, Ruberoid*Mop Plus Gramde, Ruberoie 30, Ruberoie EnergyCap' 30 FR SBS Membrane, Ruberoid* 30 FR or Ruberoie Mop FR, in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 tbs./sq. Or One or mom plies of Ruberoie Mop Smooth, RuberoW* Mop Granule, RoofflatcW" SBS Modified Granular, Ruberoie Mop 170 FR, Ruberoie Mop Plus Granule, Ruberoie 20, Ruberoid* 30, Ruberoie EnergyCap�30 FR SBS, Membrane, Rubemid* 30 FR or Ruberoid" Mop FR adhered in MatrixTm 102 SBS Surfacing-. Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1 Gravel or slag applied at 400 lbsJsq. and 300 lbsJsq. respectively in a flood coat of approved asphalt at 60 lbsJsq. 2 r GAFGLAS* Ener gyCapm BUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 IbsJsq- I Topcoat* Elastomeric Roofing Membrane,;Topcoat* MB Plus (to be used as a primer with Topcoat* Elastomeric Roofing Membrane) or Topcoats` Surface Seal SE; applied at I to 1.5 galisq. Maidmom Design Pressure; See Fastening above NOA No.: 13-0424.14 Expiration Date: 11AW14 Approval Date: 10/3hq3 Page 26 of 29 Wom) DwK SysTlEm lxt=AmNs: I A slip sheet is required with GAFGLASO Ply 4 and GAFGLAS* FlexPly ' 6 when used as a mechanically f4tmed base or anchor sheet. 2. Minimum 1/4" DensDecV Roof Board or '/?" Type X gypsum board is acceptable to be installed directly over the wood deck. GmEPAL LnwAnom: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. Insulation may be installed in multiple layers- The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment When applied in approved asphalt, panel size shall be 41 x 41 maximum. 4. An overlay andfor recovery board insulation panel is required on all applications over closed cell foarn insulations when the base sheet is fully mopped- If no recovery board is used the base sheet shall be applied using,spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped r ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation- Encircling ofthe strips isnot acceptable. A.6" break shall be placed every IT in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attached systems s be limited to a maldmum, 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-UsW4 are below 275 lbf insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base shed or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared signed and sealed by a Florida Registered, Engineer, Architect; or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from TestiagApplication Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base: sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When thrix limitation is spec ffically referred within this NOA, General bmitittion #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, andtor flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure ltation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners) Neither rational analysis, nor extrapolation shall be permitted for (When this hmitafdon is speeffically referred within this WOA, General Limitation #7 Will not be applicaW) 10. All products listed herein shall have a quality assurance audit in accordance with. the Florida Building Code and -Rule 9N-3 of the Florida Administrative Code. END OF MS ACCEPTANCE NOA No..- 13-0424.14 ExpiratianDate' 11AW14 Approval Daft: I KUM ftV 29 of Z4 TGFU.R1306 - Roofing Systems Surfacing (Optional)., — "TOPCOAT@ EnergyCote— Elastomeric Coating" applied at a rate of 2-gal/100-W. 16. Deck: NC Incline: 1/2 Page 4 of 47 Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or adhered with "LRF Adhesive M" or OMG Inc. "Oiybond Fastening System" applied as a nominal 3/4 -in. bead or "GAF 2 -Part Roofing Adhesive" applied as a nominal 2 -1/2 -in. bead with a maximum on -center spacing of 12 -in. or any UL Classified insulation adhesive applied per the manufacturer's installation instructions. Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply® #75 Base Sheet", mechanically fastened Ply Sheet: — One or two plies Type GI "GAFGLAS@ Ply 4" or "Tri -Ply® 4" or "GAFGLAS@ Flex -Ply" 6" or Type G2 "GAFGLAS® #75 Base Sheet" or "Tri-Piy@ #75 Base Sheet", fully adhered with hot roofing asphalt. Cap Sheet- — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt Surfacing: — "TOPCOAT@ EnergyCote— Elastomeric Coating" or "TOPCOAT@ MB Plus" or 'TOPCOAT@ 322 White Elastomeric Coating", applied at a rate of 2-gal/100-ft. 17. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Barrier Board: — Minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard— Roofboard" or minimum'/4-in. thick Untied States Gypsum Corp. "SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -in. from plywood deck joints. Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply #75 Base Sheet" mechanically fastened Ply Sheet — One or two plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply 4" or "GAFGLAS@ Flex Ply 6" or Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply #75 Base Sheet" fully adhered with hot roofing asphalt. Cap Sheet- — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt. Surfacing: — "TOPCOAT@ EnergyCote— Elastomeric Coating" or "TOPCOAT@ MB Pius" or "TOPCOAT@ 322 White Elastomeric Coating" applied at a rate of 2-gal/100-ft?. 18. Deck: NC Incline: 1 Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or adhered with "LRF Adhesive M" or OMG Inc. "Olybond Fastening System" applied as a nominal 3/4 -in. bead or "GAF 2 -Part Roofing Adhesive" applied as a nominal 2 -1/2 -in. bead with a maximum on -center spacing of 12 -in. or any UL Classified insulation adhesive applied per the manufacturer's installation instructions. Base Sheet. — One ply "GAFGLAS@ Stratavent@ Eliminator— Venting Base Sheet" or Type G2, fully adhered with hot roofing asphalt Ply Sheet: — One or two plies "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid@ 20" or "Ruberoid@ 20 HT", fully adhered with hot roofing asphalt Membrane: — One ply "GAFGLAS@ Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt Surfacing: — "TOPCOAT@ EnergyCote— Elastomeric Coating" or "TOPCOAT@ MB Plus" or "TOPCOAT@ 322 White Elastomeric Coating" applied at a rate of 2-gal/100-fl?. 19. Deck: C-15/32 Incline: 1 Insulation (optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive. Barrier Board: — Minimum ys-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardl Roofboard" or minimum'/4-in. thick Untied States Gypsum Corp. "SECUROCK@ Roof Board" (Type FRX-G) or "SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -in. from plywood deck joints. Base Sheet: — One ply "GAFGLAS@ Stratavent Eliminator Venting Base Sheet" fully adhered with hot roofing asphalt Ply Sheet: — One or two plies "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth Plus" fully adhered with hot roofing asphalt Membrane: — One ply "GAFGLAS@ Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt Surfacing: — "TOPCOAT@ EnergyCoteTM Elastomeric Coating" or "TOPCOAT@ MB Pius" or "TOPCOAT@ 322 White Elastomeric Coating" applied at a rate of 2-gal/100-1`1:2. Base Sheet: — or "Tri -Ply® #75 Base Sheet" mechanically fastened. Insuliation (Optional): — Any thickness or combination: perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or hot mopped or adhered with OMG Inc. "OI Bond Fastening System" or an UL Classified insulation adhesive. Base Sheet: —=or more plies �or "Ruberoid@ 20 HT" ,�or mechanically attached. Cap Sheet: —=ply Type G3 or 'Tri -Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap- BUR Mineral Surfaced Cap Sheet." 1. Deck: C-15/32 Class 8 Incline: 3-1/2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or periite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Two or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Pty 6" mechanically fastened Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Pty@ Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap— BUR Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt. 2. Deck: C-15/32 Incline: 3-1/2 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Base Sheet — Two or more plies Type G or Type G2 or Type G3. h"://database.ul.com/cgi-bin/XYV/template/LISEXT/ I FRAME/showpage.html?name=T... 4/30/2014