ELC-14-817Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-211236 Permit Number: ELC-4-14-817
Scheduled Inspection Date: July 17, 2014 Permit Type: Electrical - Commercial
Inspector: Devaney, Michael
Owner: , TROPICAL CHEVROLET
Job Address: 8880 BISCAYNE Boulevard
Miami Shores, FL
Project: <NONE>
inspection Type. Final
Work Classification: Sign
Phone Number (305)754-7551
Parcel Number 1132060200880
Contractor: MCNEILL SIGNS INC Phone: (954)946-3474
nment comments
EAST ELEVATION WALL SIGN "CHEVROLET"- -----
INSPECTOR COMMENTS False
Inspector Comments
Passed
Failed
Correction
Needed
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
July 16, 2014 For Inspections please call: (305)762-4949 Page 5 of 28
Miami Shores Village
Building Department APR 2 3 2014
10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY:
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.494
FBC 20
BUILDING Permit No.8l_
PERMIT APPLICATION Master Permit No.'4;r � !y' s
Permit Type: Electrical
JOB ADDRESS: 8880 Biscayne Blvd.
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#: 11-3206-020-0870
33138
Is the Building Historically Designated: Yes NO Flood Zone:
OWNER: Name (Fee Simple Titleholder): TROPICAL CHEVROLET INC Phone#: (305) 754-7551
Address: 8880 BISCAYNE BLVD
City: Miami Shores
State: FL
33138
Tenant/Lessee Name: TROPICAL CHEVROLET INC Phone#: (305) 754-7551
Email: N/A
CONTRACTOR: Company Name: McNeill Signs Inc. Phone#: (954) 946-3474
Address: 555 South Dixie Highway East
City: Pompano Beach State: FL Zip: 33060
Qualifier Name: Jay McNeill Phone#: (954) 946-3474
State Certification or Registration #: ES12000166 Certificate of Competency #:
Contact Phone#: (954) 946-3474 Email Address: Bsolana@Mcneilisigns.com
DESIGNER: Architect/Engineer: Dynamic Engineering Solutions Inc Phone#: (954) 545-1740
Value of Work for this Permit: $_ r�oi Square/Linear Footage of Work: 79-71/- S� �
Type of Work: ❑Address ❑Alteration ❑New ❑Repair/Replace ❑Demolition
Description of Work: 'FAS k "F_ I eV0 � Or j„LdSr 5 n %GGV/alb
Submittal Fee $ CJ `V Permit Fee $ Z=;E ,*Oa CCF $ CO/CC $
Scanning Fee $
Radon Fee $
Notary $ Training/Education Fee $
Double Fee $ Structural Review $
DBPR $ Bond
Technology Fee $
TOTAL FEE NOW DUE $
Ronding Company's Name (if applicable) n/
Bonding Company's Address /Y
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signatur G%/ Signature
Owner or Agent
The forego .ng instrument was acknowledged before me this
day of Cr / , by _774 Alt4A y P -As ..
w s personall k o me or who has produced
As identification and who did take an oath.
!� Contractor
The foregoin instrument was acknowledged before me this
day of 20�-" , by ✓ ��'
who isonall to me or who has produced
as idAntification and who did take an oath.
NOTARY PUB
NOTARY P
i.0
- ROBEERRT`O J SOLANA
i'"•., OBERTO J. SOLANA
MWy paper - State of Florida
Sign:
••�;9
Notar Public -State of Florida
Sign:Comm.
Upkes
Expires Mat 20, 2011
'. ; •: My Comm. Expires
Commission # IFF 104
Print:Gqm
„ F 104 34
''�'�'f
Print:
Mss
Oi itfg'd-, n.,,,.wA NM AM
'"'����"''� ����~Y�
My Commission Exp'
My Commissi
APPROVED BY >�/Z— X7,6&�2, Plans Examiner Zoning
"7 v Structural Review Clerk
(Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09)
n ..
ze r ve'1J��r-' W/I ^,fib
FRONT ELEVATION
ERMli
MIAMI SHORES VILLAGE
aPPROVED BY DATE
ZONING
I aTRUCTURAL 13
LECTRICAL
PLUMBING
k4ECHANICAL
BLDG.
SUBJECT TO COMPLIANCE WITH ALL FEDERAL
;;ATE AND COUNTY RULES AND REGULATIONS)
(;I fy
COPY
a"
aLn-n
1 = I
U
25" Chevrotef Bov4e 2010 & 2e Chewdet Signature wu 2scvwH - Wtft Facea
GfBM 25CVGN
APR 2 3 2014
Dynamic Engineefing Soletlout Inc.
lopn N. BmSiaer, PE 52733, ED 26629
1958 N. FedeM NW. Seita 212 .
? Pomo Beach, R 33862
t
Dynamic Engineering Solutions, Inc -
John H. omslaer, PE 52733, E826829
950 N. Federal Nwy. SW%212
- pompano Reach, FL 33062
DESIGNED IN COMPLIANCE 2010 F ORIDA UILDI CODE,
SECTION 1609 AND ASCE 7-101-
V(ULT)
-1JV(ULT) WIND SPEED E10 MPH /
EXPOSURE CLASSIFICATION = C
RISK CATEGORY = II G
DESIGN PRESSURE F
X
SUPPLY
OR
SLOAN SPLICE
CONNECTOR
#12 THHN TO PRIMARY E
SOURCE IN 1/2" CONDUIT
120 V LISTED, GROUNDED I
SLOAN POWER SUPPLY IN RACEWAY
12 VDC SECONDARY
LISTED
20 AMP
W/P
DISCONNECT
SIDE VIEW SWITCH
/METAL
TRANSFORMER
�ENCLOSURE
WALL
5" DEEP.063"ALUMINUM LETTER WITH
HIGH REFLECTIVE WHITE FINISHED INSIDE
#12 THIN TO PRIMARY ELECTRICAL
SOURCE IN 1/2"`CONDUIT
ACRYLIC PLASTIC FAC
SECURED w/ 1" WIDE .
TRIMCAP (or) RETAINERS
W/#8 x 1/2" S.M.S.
QTY. SOURCE TYPE
AMPS TOTAL
POWER SUPPLY
(3) MIN. PER LETTER)
•
�e
L.E.D. MODULE MOUNTED BACK
FLEXIBLE CONDUIT LOCKNUT
1/2" LIQUITITE FLEXIBLE CONDUR
#10 x 11)2" SCREWS IN LEAD
ANCHORMIN. PER LETTER)
POWER SUPPLY SNCL URE FASTENED W/
#10x 1 1/2"SCREWS
(MIN. 4 PER CAN)
LISTED W/P 20 AMP DISCONNECT
Attic(soffd locations requiring
one (1) lighting outlet near the
sign equipment and controlling
usual point of entry to the space.
120 V LISTED, GROUNDED SloanLED
POWER SUPPLY
LISTED 20 AMP W/P
DISCONNECT SWITCH
FOR ALL OUTDOOR LOCATIONS, ALL RACEWAYS FITTINGS
AND BOXES ARE WEATHERPROOF AND INCLUDE DRAIN HOLES
NOTE: ALL ELECTRICAL COMPONENTS CONFORM TO UL 48 STANDARDS FOR
SAFETY A
ELECTRICAL
Sign to be listed as per NEC 600.3.
Sign to have disconnect switch as per NEC 600.6 located at the end of sign or raceway. The control switch amps
rating not less than twice the ampere rating of power supplies or ballasts as per NEC 404.14 and 600.6 (B).
Branch circuits not to exceed 20 amperes as per NEC 600.5 (A) & (B).
Groundin and bonding as per NEC 600.7 (A) and (B) includingarticle 250.
Equipmen grounding to be grounded by connection as pper N 600.7 (a) (1) and 250.118.
Grounding conductor sizing as per NEC 600.7 and 250.122.
Equipmenggrounding connection to be in accordance with 250.8.
power suppTes grounded as per NEC 600.7.
Sign to be marked as per NEC 600.4 (A). Power supplies marked as per NEC 600.23 (F).
Section signs to be marked and installation instructions provided as per NEC 600.4 (C).
Sufficient number of 1/4" drain holes as per NEC 600.9 (D).
Primary wiring as per NEC 600.21 within the sign as per NEC 600.22. Grounding as per NEC 600.7 and article 250.
Power supplies as per NEC 600.24 (A), (B) and (C).
Attic/soffit sign equipment locations requiring at least one (1) lighting outlet containing a disconnect near the sign
equipment as per NEC 600.21 (E).
Power suVFlies as per NEC 600.21, 600.23 and 600.32.
Poly -Lok sill and secondaryground fault protection in compliance with UL 2161.
Primary conductors strain relief required as UL 48
All sign circuits must be on time clocks as per: FL. E.E.C. 505.2
THE MANUFACTURER REQUIRES THAT ALL COMPONENTS
BE LISTED BY A RECOGNIZED TESTING SERVICE
is, Inc.
1956 57th2013
ANNIVERSAR:]Y
SIGN TO BE GROUNDED IN ACCORDANCE WITH
2008 NEC ARTICLE 250 AND 600.7
LED MODULE
Attidsoffit locations requiring
one (1).lighting outlet near the
sign equipment and controlling
usual point of entry to the space.
SloanLED POWER SULLY
IP 55 - Rated
120 VAC Primary
12 VDC Secondary
Class It Wiring per NEC
Overload protection
SloanLED. SUPPLY WIRE
7 -Strand, 14 Gauge Wire
�i UL outdoor low -voltage lighting cable
e; l Similar metals and PVC -insulated cropper
SloanLED SPLICE CONNECTORS
Positive snap -locking mechanism
Similar metals for corrosion resistance
VOLTAGE 120
ALL ELECTRICAL COMPONENTS ARE 0 LISTED
SIGN GROUNDED ACCORDING TO NEC 250
QTY. SOURCE TYPE
AMPS TOTAL
POWER SUPPLY
Z •-7
TOTAL
AMPS 2 •'7
This sign is intended to be installed in accordance with the requirements of Article 600 of the
National Electrical Code and/or other applicable local codes. This includes proper grounding and
bonding of the sign.
1.
2.
3.
4.
5.
6.
7.
w% (,.utero
Installation instructions
Mount sign as required on engineered design drawings.
install and penetrate pattern to locate and mark all mounting and electrical conduit
penetrations.
Seal all wall penetrations.
Connect secondary and primary supply conductors to provided splice connection
conductors inappropriate splice compartment enclosure as intended and required by
applicable codes.
Make Al( electrical connections and test light
Installation of all wiring and electrical connections must conform to national
electrical code requirements.
Sign and structural must be properly grounded per requirements of national
electrical code and applicable local codes.
Do not test light sign using the service truck generator.
Make sure service truck frame and body are grounded to earth ground
before servicing the sign.
Electrical connection must be made on a dedicated 120v connection.
Confirm proper line voltage with voltage meter prior to connecting
conductors to supply conductors.
Locate and mark to identify branch circuit(s) in electrical panel.
Clean product of any fingerprints and installation debris.
Clean site of all installation debris.
Dynamic Engineering Solutions, Inc.
John H. Omslaer, PE 527331 EB26829.
950 N. Federal Hwy. StA9212
pompano Beach, FL 33�
DESIGNED IN COMPLIANCE 2010 FLORIDA PUILPINA90D
SECTION 1609 AND ASCE7- 0
V(ULT) WIND SPEED 17P MPH
EXPOSURE CLASSIFICATION = C (
RISK CATEGORY= II l
DESIGN PRESSURE PSF
pawl t
i S