Loading...
ELC-14-817Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-211236 Permit Number: ELC-4-14-817 Scheduled Inspection Date: July 17, 2014 Permit Type: Electrical - Commercial Inspector: Devaney, Michael Owner: , TROPICAL CHEVROLET Job Address: 8880 BISCAYNE Boulevard Miami Shores, FL Project: <NONE> inspection Type. Final Work Classification: Sign Phone Number (305)754-7551 Parcel Number 1132060200880 Contractor: MCNEILL SIGNS INC Phone: (954)946-3474 nment comments EAST ELEVATION WALL SIGN "CHEVROLET"- ----- INSPECTOR COMMENTS False Inspector Comments Passed Failed Correction Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. July 16, 2014 For Inspections please call: (305)762-4949 Page 5 of 28 Miami Shores Village Building Department APR 2 3 2014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY: Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.494 FBC 20 BUILDING Permit No.8l_ PERMIT APPLICATION Master Permit No.'4;r � !y' s Permit Type: Electrical JOB ADDRESS: 8880 Biscayne Blvd. City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: 11-3206-020-0870 33138 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): TROPICAL CHEVROLET INC Phone#: (305) 754-7551 Address: 8880 BISCAYNE BLVD City: Miami Shores State: FL 33138 Tenant/Lessee Name: TROPICAL CHEVROLET INC Phone#: (305) 754-7551 Email: N/A CONTRACTOR: Company Name: McNeill Signs Inc. Phone#: (954) 946-3474 Address: 555 South Dixie Highway East City: Pompano Beach State: FL Zip: 33060 Qualifier Name: Jay McNeill Phone#: (954) 946-3474 State Certification or Registration #: ES12000166 Certificate of Competency #: Contact Phone#: (954) 946-3474 Email Address: Bsolana@Mcneilisigns.com DESIGNER: Architect/Engineer: Dynamic Engineering Solutions Inc Phone#: (954) 545-1740 Value of Work for this Permit: $_ r�oi Square/Linear Footage of Work: 79-71/- S� � Type of Work: ❑Address ❑Alteration ❑New ❑Repair/Replace ❑Demolition Description of Work: 'FAS k "F_ I eV0 � Or j„LdSr 5 n %GGV/alb Submittal Fee $ CJ `V Permit Fee $ Z=;E ,*Oa CCF $ CO/CC $ Scanning Fee $ Radon Fee $ Notary $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond Technology Fee $ TOTAL FEE NOW DUE $ Ronding Company's Name (if applicable) n/ Bonding Company's Address /Y City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur G%/ Signature Owner or Agent The forego .ng instrument was acknowledged before me this day of Cr / , by _774 Alt4A y P -As .. w s personall k o me or who has produced As identification and who did take an oath. !� Contractor The foregoin instrument was acknowledged before me this day of 20�-" , by ✓ ��' who isonall to me or who has produced as idAntification and who did take an oath. NOTARY PUB NOTARY P i.0 - ROBEERRT`O J SOLANA i'"•., OBERTO J. SOLANA MWy paper - State of Florida Sign: ••�;9 Notar Public -State of Florida Sign:Comm. Upkes Expires Mat 20, 2011 '. ; •: My Comm. Expires Commission # IFF 104 Print:Gqm „ F 104 34 ''�'�'f Print: Mss Oi itfg'd-, n.,,,.wA NM AM '"'����"''� ����~Y� My Commission Exp' My Commissi APPROVED BY >�/Z— X7,6&�2, Plans Examiner Zoning "7 v Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) n .. ze r ve'1J��r-' W/I ^,fib FRONT ELEVATION ERMli MIAMI SHORES VILLAGE aPPROVED BY DATE ZONING I aTRUCTURAL 13 LECTRICAL PLUMBING k4ECHANICAL BLDG. SUBJECT TO COMPLIANCE WITH ALL FEDERAL ;;ATE AND COUNTY RULES AND REGULATIONS) (;I fy COPY a" aLn-n 1 = I U 25" Chevrotef Bov4e 2010 & 2e Chewdet Signature wu 2scvwH - Wtft Facea GfBM 25CVGN APR 2 3 2014 Dynamic Engineefing Soletlout Inc. lopn N. BmSiaer, PE 52733, ED 26629 1958 N. FedeM NW. Seita 212 . ? Pomo Beach, R 33862 t Dynamic Engineering Solutions, Inc - John H. omslaer, PE 52733, E826829 950 N. Federal Nwy. SW%212 - pompano Reach, FL 33062 DESIGNED IN COMPLIANCE 2010 F ORIDA UILDI CODE, SECTION 1609 AND ASCE 7-101- V(ULT) -1JV(ULT) WIND SPEED E10 MPH / EXPOSURE CLASSIFICATION = C RISK CATEGORY = II G DESIGN PRESSURE F X SUPPLY OR SLOAN SPLICE CONNECTOR #12 THHN TO PRIMARY E SOURCE IN 1/2" CONDUIT 120 V LISTED, GROUNDED I SLOAN POWER SUPPLY IN RACEWAY 12 VDC SECONDARY LISTED 20 AMP W/P DISCONNECT SIDE VIEW SWITCH /METAL TRANSFORMER �ENCLOSURE WALL 5" DEEP.063"ALUMINUM LETTER WITH HIGH REFLECTIVE WHITE FINISHED INSIDE #12 THIN TO PRIMARY ELECTRICAL SOURCE IN 1/2"`CONDUIT ACRYLIC PLASTIC FAC SECURED w/ 1" WIDE . TRIMCAP (or) RETAINERS W/#8 x 1/2" S.M.S. QTY. SOURCE TYPE AMPS TOTAL POWER SUPPLY (3) MIN. PER LETTER) • �e L.E.D. MODULE MOUNTED BACK FLEXIBLE CONDUIT LOCKNUT 1/2" LIQUITITE FLEXIBLE CONDUR #10 x 11)2" SCREWS IN LEAD ANCHORMIN. PER LETTER) POWER SUPPLY SNCL URE FASTENED W/ #10x 1 1/2"SCREWS (MIN. 4 PER CAN) LISTED W/P 20 AMP DISCONNECT Attic(soffd locations requiring one (1) lighting outlet near the sign equipment and controlling usual point of entry to the space. 120 V LISTED, GROUNDED SloanLED POWER SUPPLY LISTED 20 AMP W/P DISCONNECT SWITCH FOR ALL OUTDOOR LOCATIONS, ALL RACEWAYS FITTINGS AND BOXES ARE WEATHERPROOF AND INCLUDE DRAIN HOLES NOTE: ALL ELECTRICAL COMPONENTS CONFORM TO UL 48 STANDARDS FOR SAFETY A ELECTRICAL Sign to be listed as per NEC 600.3. Sign to have disconnect switch as per NEC 600.6 located at the end of sign or raceway. The control switch amps rating not less than twice the ampere rating of power supplies or ballasts as per NEC 404.14 and 600.6 (B). Branch circuits not to exceed 20 amperes as per NEC 600.5 (A) & (B). Groundin and bonding as per NEC 600.7 (A) and (B) includingarticle 250. Equipmen grounding to be grounded by connection as pper N 600.7 (a) (1) and 250.118. Grounding conductor sizing as per NEC 600.7 and 250.122. Equipmenggrounding connection to be in accordance with 250.8. power suppTes grounded as per NEC 600.7. Sign to be marked as per NEC 600.4 (A). Power supplies marked as per NEC 600.23 (F). Section signs to be marked and installation instructions provided as per NEC 600.4 (C). Sufficient number of 1/4" drain holes as per NEC 600.9 (D). Primary wiring as per NEC 600.21 within the sign as per NEC 600.22. Grounding as per NEC 600.7 and article 250. Power supplies as per NEC 600.24 (A), (B) and (C). Attic/soffit sign equipment locations requiring at least one (1) lighting outlet containing a disconnect near the sign equipment as per NEC 600.21 (E). Power suVFlies as per NEC 600.21, 600.23 and 600.32. Poly -Lok sill and secondaryground fault protection in compliance with UL 2161. Primary conductors strain relief required as UL 48 All sign circuits must be on time clocks as per: FL. E.E.C. 505.2 THE MANUFACTURER REQUIRES THAT ALL COMPONENTS BE LISTED BY A RECOGNIZED TESTING SERVICE is, Inc. 1956 57th2013 ANNIVERSAR:]Y SIGN TO BE GROUNDED IN ACCORDANCE WITH 2008 NEC ARTICLE 250 AND 600.7 LED MODULE Attidsoffit locations requiring one (1).lighting outlet near the sign equipment and controlling usual point of entry to the space. SloanLED POWER SULLY IP 55 - Rated 120 VAC Primary 12 VDC Secondary Class It Wiring per NEC Overload protection SloanLED. SUPPLY WIRE 7 -Strand, 14 Gauge Wire �i UL outdoor low -voltage lighting cable e; l Similar metals and PVC -insulated cropper SloanLED SPLICE CONNECTORS Positive snap -locking mechanism Similar metals for corrosion resistance VOLTAGE 120 ALL ELECTRICAL COMPONENTS ARE 0 LISTED SIGN GROUNDED ACCORDING TO NEC 250 QTY. SOURCE TYPE AMPS TOTAL POWER SUPPLY Z •-7 TOTAL AMPS 2 •'7 This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. 1. 2. 3. 4. 5. 6. 7. w% (,.utero Installation instructions Mount sign as required on engineered design drawings. install and penetrate pattern to locate and mark all mounting and electrical conduit penetrations. Seal all wall penetrations. Connect secondary and primary supply conductors to provided splice connection conductors inappropriate splice compartment enclosure as intended and required by applicable codes. Make Al( electrical connections and test light Installation of all wiring and electrical connections must conform to national electrical code requirements. Sign and structural must be properly grounded per requirements of national electrical code and applicable local codes. Do not test light sign using the service truck generator. Make sure service truck frame and body are grounded to earth ground before servicing the sign. Electrical connection must be made on a dedicated 120v connection. Confirm proper line voltage with voltage meter prior to connecting conductors to supply conductors. Locate and mark to identify branch circuit(s) in electrical panel. Clean product of any fingerprints and installation debris. Clean site of all installation debris. Dynamic Engineering Solutions, Inc. John H. Omslaer, PE 527331 EB26829. 950 N. Federal Hwy. StA9212 pompano Beach, FL 33� DESIGNED IN COMPLIANCE 2010 FLORIDA PUILPINA90D SECTION 1609 AND ASCE7- 0 V(ULT) WIND SPEED 17P MPH EXPOSURE CLASSIFICATION = C ( RISK CATEGORY= II l DESIGN PRESSURE PSF pawl t i S