Loading...
CC-13-2139 (5)Miami Shores Village Building Deparrnen DEC 3 Q 2013 10050 N.E.2nd Avenue, Miami Shores, Florida 33138; Tel: (305) 795,2204 Fax, (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 201 BUILDING Permit No. Deft76 PERMIT APPLICATION Master Permit No. Cc 13 21 S'� JOB ADDRESS: City; M Shores County: Miami Dade Tap: Foli(vParcel#: Is the Building HWrically Designated: Yes ........................... . ..... I ­ NO Plow Zone: OWNER, Name (Fee Simple Titleholder). —Phone#; Address: Uelr City: Zip: TenanYWsee Name: Phone#: Email; ............ --y 9 CONTRACTOR: Company Name: —Phone#:• Address: City: 4c"- os'-- -state: Qualifier Name: Phone#: State Certification Or Registration DESIGNER: Arc-hitecttlingineer; Certificate of Competency #; il Address. '9J ­._ f e'7�-'—_7'4"­.Z. Phone4: Value of Work for this Permit: Square/Linear Footage of Work: L � C Type of Work: UAddition LIAlteration LINew L31tepair/Replace _" ,Demolition Description of Work: Vr_­-( Submittal Fee $_ Senning Fee $ Color thru tile: Permit Fee Radon Fee $ Notary $_ Training/Education Fee Double Fee $ Structural Review $ CCF $_ COICC $ DBPR $ Bond $_ Technology Fee $ TOTAL FEE NOW DUE $ 0 0 V 1prp�Bonding Company's Name (it applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State =1 Zi Application is hereby made to obtain a permit to do the work and installations as indicated, I certify that no work or installation has comnienced prior to the issuance of a permit and that all work will be Performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HExrERS,TANKS and AIR CONDITIONERS, ITC..... OWNER'S AFFIDAVIT; I certify that all the foregoing information is accurate mid that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Nonce to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signatule_,- Owner or Agent Contractor The foregoing instrument was acknowledged before me this The foregoing instrument was acknowledged before ine this Z day of 20i-3—, by �AAI L16d?y,'A- day of. 4& e 21YJ-V— >,_Z 4 ,-;9 -, by e7,�p who is personally known to me or who has produced— whoi�,.Mrsonally known Rme or who has produced Asidentification and who did take an oath. - as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My C APPROVED BY Vikidil IQ Al CKAAKI - State of Florida Commission # EE 84053 Plans Examiner Structural Review (Revised 3/l2/2Ol2XRevisedG7/IW7)(RevisedO6/lOf2OW)(Reviwd 3115M) NOTARY PUBLIC: Si2n: Prin - My Comm' MY COMM. Expires Apr 21, 2017 commission # FF 10197 'or"" "rough National Notary Assn. Clerk Urgent Reply ASAP Please comment x Please review For your information In response to your Building Critique Review, Permit No: CC13 2139 dated December 24, 2013; 1. SHEET TOi, AS PER FBC 2010, EXISTING BUILDINGS,THE LEVEL OF ALTERATION FOR THIS PROJECT SHOULD BE CLASSIFIED AS A LEVEL 2 ALTERATION. a. References to Level 1 Alteration have been deleted. Sheet T01 is revised to read Level 2 Alteration only. 2. ADDITIONS AND ALTERATIONS TO EXISTING BUILDINGS OR FACILITIES SHALL COMPLY WITH SECTION 202 OF THE 2010 FLORIDA BUILDING CODE, ACCESSABILITY. SHEET AS 100, SHOW THE LOCATION OF THE REQUIRED ADA ACCESSIBLE PARKING STALLS AND ACCESSIBLE ROUTE TO THE BULIDING.SHEET A401, DETAIL 11, PARTIAL FLOOR PLAN FOR THE BATHROOM, SHOW COMPLIANCEWITH THE REQUIREMENTS OF THE ACCESSIBILITY CODE. PROVIDE DIMENSIONS AND SHOW THE CLEAR FLOOR SPACE OF FIXTURES. a. Locations of existing barrier free parking spaces, existing accessible route and existing barrier free pedestrian ramp to remain have been added to revised Sheets AS100 and A100 b. Sheet A401 Detail 11 has been revised. Existing wall mounted lavatories have been deleted from Men 124 and WOMEN 126 barrier free toilet stalls. Required clearances have been provided. Clear floor space indicators have been added, urinal and privacy partition locations have been revised to provide clear floor spaces, MEN 124 door has been revised to swing out of the space, providing clearance for a front approach. t , 3. PROVIDE GUARD RAILS ALONG OPEN SIDES OF WALKING SURFACES LOCATED MORE THAN 30 INCHES HIRRIZONTLY TO THE FLOOR OR GRADE BELOW. SHEET A311, DETAIL 2 IS MISSING THE BOTTTOM SECTION OF THE DETAIL, PLEASE SHOW THE HIGTH OF THE CHANGE OF ELEVATION. WALL SECTION 3/A310. THERE IS A DROP OF MORE THAN 30" ON THE OPOSITE SIDE OF THE DECK AT THE COVERED SERVICE RECEPTION, THE RAILING ONLY EXTEND TO 39- 3/4". FBC, SECTION 1013.2 REQUIRES THE GUARDS TO BE 42" ABOVE ADJACENT WALKING SURFACE. a. Sheet A311 Detail 2 has been revised to include the existing lawn berm that slopes down from the existing raised concrete display platform to the existing parking areas. Guard rails are not required because there is not drop of more than 30 b. Sheet A310 Section 3, dimensions have been added and clarified. The proposed guard measures 42 1/4" high above the adjacent edge of slab (slab slopes down from finish floor toward edge), complying with FBC, Section 1013.2. 4. SHEET A301, FLOOR PLAN, PROVIDE DETAIL AND SPECIFICATIONS FOR THE NEW CONCRETE STAIRS, SPECIFIED TREAD AND RISER DOMENSIONS AND PROVIDE DETAIL AND SPECIFICATIONS OF THE RAILING SYSTEM. a. Stair construction details (number of treads and depth, number of risers and height, nosing; handrail dimensions, etc) are shown on revised Sheet A301; Detail 1. Enlarged plan details (width, handrail dimensions, etc) are shown on revised Sheet A430, Details. Additional handrail performance requirements are included in Section 2013-069 057200 Aluminum Handrails and Railings of the 8x11 Specification Booklet (attached for your convenience). 5. SPECIFIED THE WIDTH OF CORRIDOR 115 a. Corridor 115 is an extension of the existing corridor matching the existing width, 5'-3 1/4", as shown on revised Sheet A100. 6. PROVIDE KNEE AND TOE CLEARANCE AS REQUIRED ON SECTION 306 OF FBC ACCESSIBILITY FOR THE SINKS ON ROOMS 130 AND 123. a. Knee and toe clearance is not required for rooms 130 and 123 sinks. We provided a parallel approach, per FBC, Accessibility, Section 606.2, Exception 1 A parallel approach complying with 305 shall be permitted to a kitchen sink in a space where a cook top or conventional range is not provided and to wet bars. 7. SHEET A904. N.O.A. 09-0518.09 FOR YKK AP AMERICA EXPIRED ON JUNE 10, 2010. PLEASE PROVIDE NEW N.O.A. FOR THE PRODUCT a. YKK AP America has stopped supporting N.O.A documentation. The current product approval documentation for Series 35H Outswing Door is FL#: 12522.1. Sheets A904 and A905 have been revised to include FL#: 12522.1 information. 8. ROOF SYSTEM SHOULD BE VENTED AS REQUIRED UNDER SECTION 1519.15 OF FBC 2010. PLEASE SPECIFIED ON THE ROOF PLAN THE TYPE, SIZE AND LOCATION OF THE REQUIRED ROOF VENTING SYSTEM TO BE USE. a. The area of new roof (open sided Covered Service Reception) will be ventilated Per FBC 2010, Section 1519.15. Roof vents and details have been added to revised sheet A140. Structural Critique Sheet Permit No: CC13-2139 dated December 21, 2013 1. A100 -Provide wall legend a. A Wall Construction Key Legend is provided on revised sheet A100 2. S2.0 - Provide legend for proposed and existing a. Hatching has been added to sheets S2.0 and S2.1 to delineate new and existing construction 3. S2.0 - Provide dimensions a. Dimensions have been added to define extents of new construction with respect to existing structure and grids 4. S4.0'- Dimensions are incomplete a. Tower plan dimensions are indicated. Dimensions to define vertical elevations of structural elements have been added 5. Provide special inspection forms for masonry, steel, connections & soil compaction a. Special inspection form has been prepared and submitted with Bulletin #1 for masonry and steel connections. Soil compaction inspections to be performed by a licensed geotechnical engineer 6. Provide a 3-D lateral analysis for the tower and check the steel elements & foundations. a. New tower structure is braced back to existing structure and is not a free standing tower. 2-D analysis was provided for the framing members using the existing roof line as a point of support. The added load to the existing structure does not exceed the current applied loads by more than 5%. ELECTRICAL REVIEWER COMMENTS Permit No: CC13-2139 dated December 24, 2013 1. Riser Diagram. a. The riser diagram has been added to revised sheet E302 2. Load Calculation. a. The load calculations are shown on revised sheets E300 and E302 3. Panel schedule for MDP, OL, and S panels a. The schedules are shown on revised sheets E300 and E302 PLUMBING - OSVALDO DIAZ Permit No: CC13-2139 dated December 26, 2013 1. FBC1004. PROVIDE TOTAL OCCUPANT LOAD FOR THIS OCCUPANCY. a. Total occupant load = 103 occupants, as shown on Sheet LSP102 Code Study. 2. FBC107. PROVIDE LOCATION OF WATER METER, BACKFLOW PREVENTOR, SEWER AND/OR SEPTIC SYSTEM ON SITE PLAN. a. The existing septic location is shown on sheet AS100. Symbols and notes indicating the locations of the existing water meter and existing backflow preventer(rpz) have been added to Sheet AS100. 3. FBC604.4 PLUMBING FIXTURES SHALL COMPLY WITH MIAMI DADE ORDINANCE 8-31 FOR WATER EFFICIENCY a. The plumbing fixture flow rates are in compliance with the ordinance 4. FBCP608 AS PER MIAMI DADE ORD. 32-154 A BACKFLOW PREVENTOR SHALL BE INSTALLED IF ONE CURRENTLY HAS NOT BEEN PROVIDED. a. Symbols and notes indicating the location of the existing backf low preventer (prz) has been added to Sheet AS 100 5. FBC107. HEALTH DEPARTMENT APPROVAL MY BE REQUIRED IF PROPERTY IS ON A SEPTIC SYSTEM. a. The property is on an existing septic system. However no new toilet fixtures are being added, there is no food service preparation and DERM as already approved the plans. 6. FBC ACCESSIBILITY 602. DRINKING FOUNTAIN SHALL MEET REQUIREMENT FOR SPOUT HEIGHT AS PER 602.4 AND 602.7 ONE FOR EACH OR HI-LO. a. The existing single drinking fountain will be removed and replaced with a hi-low drinking fountain meeting the spout height requirements, see revised detail 11, revised plumbing fixture schedule and new detail 16, sheet A410. 7. FBC ACCESSIBILITY 604.8.1.1 THE TOILET STALL SIZE SHALL COMPLY WITH WHEEL CHAIR MANEUVERING. a. Existing wall mounted lavatories have been deleted from Men 124 and WOMEN 126 barrier free toilet stalls and sizes of the stalls have been modified to provide required maneuvering space, see revised detail 11, sheet A410. From: Jeremy Griffis, AIA cc: File N U DELL ARCH ITECTS 500 Winderley Place, Suite 220 Maitland, Florida 32751 T 407 740 8022 F 407 740 8322 BULLETIN NO. 1 PROJECT NUMBER: 2013-069 NAME: Tropical Chevrolet LOCATION: 8880 Biscayne Blvd. Miami Shores, FL DATE OF ISSUANCE: January 10, 2014 This Bulletin covers various additions, deletions, revisions and clarifications to referenced project and is issued to establish the cost to perform the work described. Do not proceed with the work until notified verbally, in writing, or by change. order. If an immediate decision is critical so as not to hold up construction, or as not to incur additional costs by not proceeding immediately, please advise. Drawing Revisions: ARCHITECTURAL: T1 1. Revised Scope of Work to Level 2 Alterations 2. Revised title of sheets A904 and A905 to FPA FL# 125.221 YKK SERIES 35H OUTSWING ENTRANCE DOOR in lieu of NOA 09-0518.09 AS100 1. Notes added indicating locations of existing barrier free parking spaces, existing accessible route and existing barrier free pedestrian ramp to remain 2.Symbols and notes added indicating the locations of the existing water meter and existing backflow preventer(rpz) to remain LSP02 1. Revised plumbing fixture calculations to delete one existing drinking fountain and add one new hi - low drinking fountain 0100 1. Removed existing drinking fountain at Corridor 123 2. Removed existingbarrier free sinks from toilet compartments and terminated plumbing at Men 124 and Women 126 3. Removed existing frame in addition to the door to reverse the swing at Men 124 A100 1. Added new hi -low drinking fountain at Corridor 123 2. Deleted barrier free sinks from toilet compartments at Men 124 and Women 126 3. Reversed the swing of new frame and door 124 at Men 124 4. Notes added indicating' locations of existing barrier free parking spaces; existing accessible route' and existing barrier free pedestrian ramp to remain 1 ARCHITECTURAL (continued): A140 1. Added roof vents at Covered Service Reception Canopy 030 and roof vent detail A301 1. Added note referencing specifications Section 2013-069 057200 Aluminum Handrails and Railings to Section 1 A310 1. Added dimensions to Section 2 to clarify the height of guardrail above slab edge A311 1. Revised Section 2 to show existing lawn berm that slopes down from the existing raised concrete display platform to the existing parking areas A410 1. Detail 2, deleted vertical grab bar 2. Details 4, 5, 8 and 9, deleted barrier free sinks from toilet compartment 3. Detail 6, revised locations of urinals, added privacy partition near door 4. Detail 11, Deleted barrier free sinks from toilet compartments, revised toilet partition spacing, added note for self closing doors with latch at barrier free stall, revised urinal and privacy screen locations, added privacy partition near door,. reversed door to swing out of Men 124, revised locations of hand dryers, noted changing station, added hi -low drinking fountain 5. Added detail 16 hi -low drinking fountain elevation 6. Deleted 18" grab bar from T1 of Restroom Plumbing Fixture & Accessory Schedule 7. Deleted plumbing fixture P3, not.used from Restroom Plumbing Fixture & AccessorySchedule 8. Revised plumbing fixture P8 to new hi -low, in lieu of existing drinking fountain to remain Restroom Plumbing Fixture & Accessory Schedule A430 1. Notes added referencing structural drawings for concrete stair reinforcing, added note referencing specifications Section 2013-069 057200 Aluminum Handrails and Railings, added dimensions between edge of stair guard and railing A904 1. Revised sheet title 2. Added documentation of FPA FL# 12522.1 in lieu.of deleted NOA 09-0518.09 documentation for YKK SERIES 35H OUTSWING ENTRANCE DOOR A905 1. Revised sheet title 2. Added documentation of FPA FL# 12522.1 in lieu of deleted NOA 09-0518.09 documentation for YKK SERIES 35H OUTSWING ENTRANCE DOOR STRUCTURAL: S2.0 1. Added hatch and notes to delineate existing from new construction 2. Added dimensions for clarification with respect to new construction, existing structure and grids S2.1 1, Added hatch and notes to delineate existing from new construction S4.0 1. Added tower plan dimensions for clarification 2. Added dimensions to clarify vertical elevations of structural elements ELECTRICAL: E300 1. Added load calculations 2. Clarified panel schedules E302 1. Added load calculations 2. Clarified panel schedules 3. Added riser diagram PLUMBING: P001 1. Deleted wall hung lavatory 2. Added hi -low drinking fountain P100 1. Removed and terminated existing wall hung lavatories 2. Removed existing single drinking fountain P200 1. Deleted wall hung lavatories; revised associated sanitary lines P400 1. Deleted wall hung lavatories, revised associated supply lines 2. Added hi -low drinking fountain in lieu of existing single drinking fountain P500 1. Revised water and sanitary risers Drawings Issued T1, AS100, LSP02, D100, A100, A140, A301, A310, A311, A410, A430, A700, A904, A905, S2.0, S2.1, S4.0, E300, E302, P001, P100, P200, P400, P500 SPECIFICATION REVISIONS: None Specifications Issued: Section 2013-069057200 Aluminum Handrails and Railings Total pages included in this bulletin = 3 Distribution: GSD Constracting — Guy DeJohn and Greg DeJohn Miami Shores Village Building Department Prepared By: Nudell Architects - Jeremy Griffis, AIA END OF BULLETIN NO. 1