Loading...
WS-14-2545Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-223596 Scheduled Inspection Date: January 15, 2015 Inspector: Rodriguez, Jorge Owner: , B&L REALTY HOLDINGS LLC Job Address: 170 NW 97 Street Miami Shores, FL 33150 - Project: <NONE> Permit Number: WS -11-14-2545 Permit Type: Windows/Shutters Inspection Type: Final Work Classification: Garage Door Phone Number Parcel Number 1131010250030 Contractor: JB GARAGE DOORS INC Phone: (305)751-3642 tiunaing uepartment comments REPLACING 1 GARAGE DOOR INSPECTOR COMMENTS False January 14, 2015 For Inspections please call: (305)762-4949 Page 12 of 37 Inspector Comments Passed Failed Correction Needed ❑ Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. January 14, 2015 For Inspections please call: (305)762-4949 Page 12 of 37 BUILDING PERMIT APPLICATION StBUILDING ❑ ELECTRIC Miami Shores Village NOV 19 2014 Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 -fir Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 2010 Master Permit No.A S / y d% 7J Sub Permit No. ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR vim, JOB ADDRESS: l Q tV W P-1 C+-. City: Miami Shores County: Miami Dade ZID• Folio/Parcel#:A��i 01-095 •- 00:10 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): %� °� E-- Q'e� �~ 7 A cA 1 !fW Phone#:�C1(c4 Address: � 0X.-) N w �' AAn P City: kl i State: - Ft_ Zip: T X11 Tenant/Lessee Name: "�— Phone#: Email: CONTRACTO R : Company Name: ` -'s d ?a0t\_ Phone#: - 9.2;2-7670 Address:�. JL City: 1 0; A -1Q9 -h 6Q 4L --d✓ State: EVA- Zip: -3,3 0 l Qualifier Name: ) mnPhone#: SOS—:22q-6 // � State Certification or Registration #: Certificate of Competency #: Wao Mq 4 2 DESIGNER: Architect/Engineer: Phone#: Address City: State: Value of Work for this Permit: $ ,y� ° ®® Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New [ Repair/Replace Description of Work: ri°pA_0,r' t; Cpcuragin Vkor Zip: ❑ Demolition Specify color of color thru tile: r Submittal Fee $ _0.00 Permit Fee $ 0, CCF $ `' � CO/CC $ Senning Fee $ ' � Radon Fee $ � � DrBPP,R�$ 2Lr� Notary $, Technology Fee $ Q' Training/Education Fee $ ti ) Il) Double Fee $ Structural Reviews $ 22 Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) _ Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and thaw oA will all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature O E rAGENT The fofegoing instrument was acknowledged before me this SO; day of�0�. 20 J, by ikQW40l, DeVry who i ersona kno to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: as The foregoing in nt �w,a"s°atc-knowledged before me this B I ` day of �0 e'C . 20 1 4 , by 4®Q (be r4 , who is personally known to me or who has produced as identification and who did take an oath. Print: PUBLIC: IAJ Ske• 0 ems' Seal: L(4M-1 MY COMMISSION #FF158014 Seal: EXPIRES October 1, 2018rstateofS'ry PubNc arida soFloridaN Service com M8ry6g( MUStelier FYI# 1�� a�����**x�***a�*���t��x�*x�*�*x��x�x�*��*�*m*x�x�+��x*�a+��*e��x�*+�*a�x�xa���a��x�xx� � � •�x a� APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) an NOV i' 2014 IWYY,�-1 IA MIN TPIAt 1131X -)V! T�, , Oct. 30. 2014 10:1 6AM No. 2283 P. 1 iib. "".✓.F•y i ++�� .✓2 � �+r,,r.: �/4�p � `����y`aaa `/ / `�1yJ CORY"ORATION } �)��PL ••t tJL•C7':.,J' �_'CY � �1 CON'SULTING ENGINEERS & PRODUCT DEVELOPMENT 3t►Ilvn .QA!L1'A. J:&, S r GOmPONKNT S .c ICLADDI1�G _-_ ----- `YIN,T)�STANI)ARI): ASCI ' -110, FRC 2070 T,!iuj N GARAGE DOORS ONLY County: Misimi Davie gyind Speed: 115 MILE Jtisk Category: If rrpocure Ckegory : C I. c:uent 2, Project Name: :4. Project Address. 4. Building Height: h �Y t.. • �' ' `"'�' � ... .._ _..... (Rmidcntial Ymjccls Duly)) i�1 Y STATF: ' (See Figure 1 altinvc) 5. Door Sicc:: MAXIMUM DE81GN LOADS FOR BT)ILDINGS EQUAL ORLTSS'I' M 25 F ' ;.T. _F.AN `AOOI ' III'. YMBULMINONWITROOF SLOPN _ -- D003iiiin_TH F'1' 9 IT. 12 rr. I'SF(-) PCF(t)PS6() P5F(+) PSI'(-) a 1011M.IXEL, -, - FOR I--.- _ 9 IrA'. P51(F) PSI.*(-! 34,9 4$,4 35.3 45.9 35.8 46.5 36.7. 47.0 36.G 47.5 37.0 48.1 37.4 48.6 37.8 _49.1 38.2 49.7 B111.1 DING _ .._� 9 FT. 1-'Sl'i1) 34.4 34.8 35.'). 35.6 36•Q 36.4 36.8 37.9 37.6 WITH _ .! 1'Sl'(-) 44.3 44.8 45.3 45.8 4G.4 46.9 47.4 47.9 48.5 ROOF DOOR _ J 2 PSUV) 33.0 33.4 _3_3.8 34.7. 34.6 35.0 35.4 35:1 36.1 Sl.tll'L+' NYIDTH FT 1'51-(-) 41.11 42.1 42.6 43.6 -33.2 44.0 44.5 45,0_ 45.5 c10DI:CRIM, 16 i'SF{1) 31.7 32.0 32.4_ 32.8 33,5_41.2 _33_.9 34.3 34.7.42-5 F 1 _ P°,F() 38.1 39.3 39.R 40.3 40.11 41.G 42.1 _ is PSF(F) 31.18. 31.5 31.9 32.2 32.6 .3 33.3 _33.7 _34.1 r,T. 33.Z17 38.7 39.1 39.6 40.0 40,4 40.9 4i.3 ^ J6 1 -T. 1-8 rT. _ 1'Sl'(I} 34.5 1!SI'M33.9 42.41.3 PS[(} i S 38.1 49,7 37,3148.5 49.1 36.Q 45.5 36.4 46.1 41.9 50. 38.Q 39.0 50.9 3$.4 34.9 43. 497 36.9 46.6 35.3 43.42.3 18 39.5 51.5 38.8 _ 19 39.9 52.1 39.3 20 40A 52.7 39.7 50.7. 37.3 47.1 37,7 47.7 39.1 48.2 3_5.7 44.0 35.1 42.8 50.8 51.4 36.1 44.5 35.5 4 3. 2 36.5 45.0 35.9 43,7 21 40,8 53.3 40.2 5I.9 38.6 X48.7 37.0 3G.3 44.2 _ 2?. 41.3 53.8 40.6 23 41.7 54.41t4.0 52.5 39.0_ 4_9.3 37.4 _45.5 46,0 36.7 44.7 53.I 53.7 54.2 39.4 49.8 39,R 50.3 37.8 46.5 37.1 45.2 Y24 42.7 55..5 25 42.6 SS..9 39.2 47.0 37.5 45.7 46.2 38.6 50,2 38.0 49.0 36 i 40.0 35.0[43,51 43.0 34A 41.8 40.3 50.9 3R.b 47.5 39.0 50.7 38.4 49.5 36.9 46.5 35.4 34.8 422 Notes .- _ - i - h _ L'ave height for roof slope < 10 degree. - 'Cable above shows moxl)mmi design load for shown bltilding he(, -,hr In end mne. Igor tiny other conditions/:.olms, design loads to be evaluared on project basis visdoimer, , V 32014 - 771ts dacmnent is not valid withow the embossed seal ofau engineer employed visit byJ1-Haroaq Corporation 4 `4� -No poi flon of this docmnent may be used or reproduced in any manner. JAVA,D A) f MAD, P.L. (except, however, for that partion afAVCB 710 serfordi herein). E'1•# 7()5h2 EP CAN # 353R 1235 SW 87tH Avenue I h1bimi, hi, 331"14 IT: 30S.264.31001 F: 405.267..69781 wim.ufceugman I alfarooq Rfceng.coru MIAMI•D�ADE s MIAMI -I ADE COUW.y PRODUCT COZ\I I'ROL SECtION D ARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Sf#eei; Room 208 . . AFFAIRS (PERA) Miami, Florida 33175:.24-74 BOARD AND CODE ADMINISTRATION DIVISION - T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) WMY miamidade eoy/ne► n/ DAB Door Company, Inc. --_ 12195 NW 9e Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The.Miami Dade County Product Control Section an Miami Dade County) and/or the AHJ (in areas otherthan Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the *right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that tbisproduct or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: 91- 4" Wide x 16' Eliigh Steel Sectional Garage Door w/ Window Lite Option APPROVAL DOCUMENT: Drawing No. 01-09, titled "Sectional Garage Door", dated 02/01/2001, with last revision F dated 10/13/2011, sheets 1 through 5 of 5, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.B., bearing the Miami Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County product Conrtrol Section, A SSME IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model number, the positive and negative design pressure rating, indicate impact rated' if applicable, installation instruction drawing reference number, approval number (NOAJ the applicable test standards, and the statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENFWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TER YWATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shaIl be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA # 11-0119.21 and consists of this page 1 and evidence pages E-1 and E-2 as well as approval document mentioned above. ' The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 124110.06 MIAhRDADECID Expiration Date: August 9, 2016 Approval Date: March 1, 2012 0 Page I DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SMBUTTED A. DRAWINGS 1. - Drawing No. 01-09, titled "Sectional Garage Door", dated 02/01/2001, with last revision F dated 10/13/2011, sheets 1 through 5 of 5, -prepared by AI-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted underNOA # 094128.04" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 4) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a DAB 824 24 GA Sectional Garage Door with Fixed Windows, prepared by Hurricane Engineering & Testing, Inc, Test Reports No. FIETI-08-2149A/B, dated 06127/2008, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 09-0128.04" 2. Test report of Tensile Test per ASTM E 8, ReportNo. HETI 08 T182, prepared by Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by Candido F. Font, P.E. •j "Submitted under NOA # 03-0210.0.4" 3. Test report on Salt Spray (Corrosion) Test pet ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/199811 signed by W. A. Jackson, P.E. C. CALCULATIONS "Submitted under NOA # 09-0128.01" I. Arichor verification calculations prepared by AI Fasooq Corporation, complying with F.B.0 2007, dated 12/19/08, signed and sealed by Humayoun Farooq, P.E, D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting; Environment, aad Regulatory Affairs (PERA) Cirlos AL I era, P.E. Product Control Examiner X0A Nlo.12-0110.06 Expiration Date: August 9, 201.6 E-1 Approval Date: March 1, 2012 M DAB Door Company_ NOTICE OF ACCEPTANCE: EVIDENCE SUBS E• MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 08-0305.02, issued to SA13IC Innovative Plastics, for their Lexan Sheet Products, approved on 04/24/2008 and expiring on 07/17/2013. 2. Notice of Acceptance No. 07-1016.07, issued to Insulfoam, LLC, for their lm foam Expanded Polystyrene Insulation, approved on 11/29/2007 and expning on 11/29/2012. 3. Notice of Acceptance No. 07-1107.08, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 04/26/2007 and expiring on 08/27/2008. 4. Notice of Acceptance No. 07-0301.10, issued to Dyplast Products, LLC, for their Dypl /201 O -Cl Polyisocyanurate Insulation, approved on 06/07/2007 and expiring on "Submitted under NOA # 05-0228.02 j, 5. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002; dated 09/27/2004, sighed and sealed by Rafael E. Droz-Sella, P.E. 6. Test Reports on Tensile Test per ASTM D638 of "PVC Hxtrusion Material by Hurricane Engineering & Testing Inc., Report No. HETI 04-T2513 dated prepared 11/29/2004 signed and sealed by I. Ghia, P2. 7. Test Report on Self -Ignition Temperature Test, Rate of Bum Test and Smoke Density Test of "REHAU non -foam PVC extrusion material", prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L, Doldan, P,E. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC and no financial interest, issued by Al-Farooq Corporation, dated 10/26/2011, signed and sealed- by Javad Ahmad, P.E. 02 f �i/;Wl7 Carlos M. Ubw% P.E. Product Control Examiner NOA Na 12.0110.06 Expiration Date: August 9, 016 Approval Date: Mardi'1, 2012 E -2 DOOR HEIGHT CONSISTS OF 6'-6' 2 SECTIONS 18' 2 SECTIONS 21' W-9" 1 SECTION 18" 3 SECTIONS 21" W/ MIN. 5 TO 1 -SAFETY FACTOR 4 SECTIONS 21' - I(3) 5" WIDE AT 7" O.C. MAX. Y=6" 5 SECTIONS 18" - 7'-9" 4 SECTIONS 18'11 SECTION 21' 8' 3 SECTIONS 18' 2 SECTIONS 21 ° 8'-3" 2 SECTIONS 19" 3 SECTIONS 21" 8'-6" 1 SECTION 18" 4 SECTIONS 21" W-9" 5 SECTIONS 21" - 9' 8 SECTIONS 18" - 9'-3" 5 SECTIONS 18' 1 SECTION 21' W-6" 4 SECTIONS 18' 2 SECTIONS 21" 9'-9'3 SECTIONS 18' 3 SECTIONS 21" 10' 2 SECTIONS 18`4 SECTIONS 21" 10'-3" 1 SECTION 18" 5 SECTIONS 21' 10'-6' IS SECTIONS 21" - 10'-9' 6 SECTIONS 18' 1 SECTION 21" 1l' 5 SECTIONS 18" 2 SECTIONS 21' 11'-3" 4 'SECTIONS 18" 3 SECTIONS 21" 11'-6" 3 SECTIONS 18" 4 SECTIONS 21" ll' -9" 2 SECTIONS 18' 5 SECTIONS 21' 12' 1 SECTIONS 18' 6 SECTIONS 21' 1 V-3" 7 SECTIONS 21' - 12'* -6" 6 SECTIONS 18' 2 SECTIONS 21" 12'-9" 5 SECTIONS 18' 3 SECTIONS 21- 13' 4 SECTIONS 18" 4 SECTIONS 21' 13'-3" 3 SECTIONS 18" 5 SECTIONS 21' 13'-6" 2 SECTIONS 18' 6 SECTIONS 21" 13'-9' 1 SECTION 18' . 7 SECTIONS 21" 1? ­i SECTIONS 21.' - 1T-3' 6 SECTIONS 18' 3 SECTIONS 21' 14'-6' 5 SECTIONS 1 B" 4 SECTIONS 21' 14'-9' 4 SECTIONS 18" 5 SECTIONS 21' 15' • 3 SECTIONS. IB' a SECTIONS 21' 15'-3' 12 SECTIONS 18' 7 SECTIONS 21- 15'-6" 11 SECTION 18' 8 SECTIONS 21" 15'-9" is SECTIONS 21" - 7 - TOP FIXTURE 5-1/2" X 2-3/4' X 0.1" STEEL PLATE WITH ONE 5/16-18 MS W/ NUT FASTENED TO END STILE WITH OPTIONAL DOOR VIEWER (6) #14 X 3/4 SELF DRILLING SCREWS TO BE INSTALLED AT CENTER STILE CENTER STILE ] �u v z. N w m _W � c� Q2 N C5 a. Lc 0v 0° m 0'a�(0 o 0aa� 0°�`'A ao It O N n .s0�d T .158 DIA. GALV. AIRCRAFT'TYPE CABLE & NICO -PRESS SLEEVE ISI ISI WAI ISI �---►--A W/ MIN. 5 TO 1 -SAFETY FACTOR I(3) 5" WIDE AT 7" O.C. MAX. OPTIONAL FLUSH FACE ' � SII �lII I��II I Ali WOOD GRAIN DESIGN 120 SQ. IN, 6"X3"X0.1" STEEL PLATE MAX. DOOR WIDTH WITH (2) J14 X 5/8" SMS BRACKET BRACKET INSIDE ELEVATION STD. LIFT DOOR LOW HEADROOM RAISED PANEL EMBOSSED DOOR _.4 DOOR OPTION 7-7/8" X 3-1/8" X .010" �u v z. N w m _W � c� Q2 N C5 a. Lc 0v 0° m 0'a�(0 o 0aa� 0°�`'A ao It O N n .s0�d T .158 DIA. GALV. AIRCRAFT'TYPE CABLE & NICO -PRESS SLEEVE ® I `�` OPTIONAL V£NT �---►--A W/ MIN. 5 TO 1 -SAFETY FACTOR I(3) 5" WIDE AT 7" O.C. MAX. OPTIONAL FLUSH FACE ® 'OPENING AREA NOT TO EXCEED COLONIAL DESIGN WOOD GRAIN DESIGN 120 SQ. IN, 6"X3"X0.1" STEEL PLATE MAX. DOOR WIDTH WITH (2) J14 X 5/8" SMS BRACKET BRACKET INSIDE ELEVATION STD. LIFT DOOR LOW HEADROOM RAISED PANEL EMBOSSED DOOR DOOR OPTION 7-7/8" X 3-1/8" X .010" CENTER STILE PPLAATE �(4) #14 X 3/4" SDS DAB DOOR MODEL 824 MAX. SIZE 9'-4" WIDE X 16'-0" HIGH OUTSIDE HANDLE] VI END STILE n44 DESIGN PRESSURE RATING = + 50.€3 PSI= I . - 60.0 PSF LOCK BAR GUIDES INSTALLED ON END STILE WITH (4) $14 X 5/8' SMS Q .18T X .6W LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR OUTSIDE KEYED LOCK LOCK BAR LOCKING SHOWN ALTERNATE TO LOCKS SHOWN ABOVE GENERAL NOTES L THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 2010 EDITION INCLUDING HIGH VELOCITY HURRICANE ZONE 2 ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR -STUCCO. 3. ALL BOLTS, NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL 4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN THESE DETAILS ARE NOT PART OF THIS APPROVAL . e i nAn nI IRA-nnu IUmnsF m IISFII IN nMr.N TIF ANf:NnRS INTn wnnn nbliv THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT l ngr. JAYIV Aj AD , .r , PRQDUCtREVISED A-PE.N. 5 8592. �to1I "doY� iFI� �► Ivo J 1 ��1 r..�l 0 YrodLid �as9trd � DD O O C) Q C2 LA LLI � Lei g Z Wm V) rn C2 1 0 o� F O z V) m° 04 I 11J V q U C § O C7 rc 21gl� R R44 O O j C 0 7 P 1 1 q o o a5` a drawing no. 01-09 FOS CONNECTION OF WOOD BUCK TO MASONRY SEE NOTE ON SHEET 4 SOUTHERN PINE 0.55 EDG D:! DIST:! .d •ad, 4• .e'j i I 1 1/2" MIN. 1-3/16- 1.94 X 2.19" X 3.3" X .102" STEEL TRACK BRACKETS SEE SHEET 3 FOR SPACING STEEL TRACK BRACKET FASTENED SOLID BRASS DOOR VIEWER TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE' 5/16" X 1-5/8" LAG SCREW INSTALLED IN 9/18" DIA. HOLES IN CENTER STILE (FULLY THREADED) POSITIONED AT EYE LEVEL ONE PER BRACKET OPTIONAL SEN BY DOOR INSTAL) ER fl X 5/8" SMS 3 4" X 2" X 2-1/2" X 18 GA. STEEL 6 PER HINGE END STILE. CONNECT TO PANELS WITH 1/2" X 1-3/4" X .059" FORMED STEEL FLAPS AND 3/18" ALUM RIVETS GLUED TO PANEL AND SECURED TO SEE DETAIL ABOVE END STILE aIVITH 3/16" POP RIVETS ® 12" O.C, 1-7/8" X 2-5/8' X .045" -STEEL CENTER STILE, GLUED AND RIVETED TO PANEL W/ (4) 3/16' RIVETS POP RIVETS !#14 X 5/8' S.M.S. 1 4/ HINGE \ZV 7-1/2" X .050' GAW, STEEL I 2-1/8" X 1" X .078" CENTER HINGE GALV. STEEL TRACK SECTION B-6 FASTENED TO TRACK PLATES 7/16' PUSHNUT W/ 1/4-20 X 5/8" TRUSS HD. INSTALLED ON ROLLER SHAFT SLOTTED M.S. & LOCK NUT INTERIOR SIDE 7-1/2" X 3' X .071". END ROLLER HINGE 24 3/11 FLAPS BENT OVER 1/2" PUNCHED ®4 4u o 0 1 z i 0� IL 0� C°0w� o 0 0 °ce o AD 3 >v IL+ z _Ind -END STILE a co ANCHORS, O o n A) 3/8" DIA. POWER -BOLT BY 'POWERS' 2" MIN. EMBED INTO CONCRETE W O Q LL 1-7/8" 91K EDGE DISTANCE � Z � 6 B) ,3,/8" DIA. HLC SLEEVE BY 'HILTI' in 1-1/4" MIN. EMBED INTO CONCRETE OR FILLED BLOCK -� rn rjp I � 1-5/8" MIN. EDGE DISTANCE INTO CONCRETE 0: q;w 4" MIN. EDGE DISTANCE INTO FILLED BLOCK O Z C9 La CONCRETE f c = 3000 PSI MIN U-) EDGEC-90 GROUT FILLED BLOCK f'm = 2000 PSI MIN. Q N DISTANCE ae, sne . n ANCHOR TYPE A OR 8 p o l(l) PER BRACKET SEE SHEET 3 FOR BRACKET SPACING o Z a c I I m C a= z 1.82" DIA. X .50" NYLON/STEEL ROLLERS W/ .44 DIA. X 4-1/4" STEM 1/4-20 SS BOLT & NUT CIVIL FLA. -PE,-17 C.A,N. 838 0 an comoft vd*lw f brwa asaiwe 066 • 0 D 5 Br pradn�t!Qooscol drawing no. 01-09 2" POP RIVETS 2-3/4' X 5-1/2" X 3" X .104" GALV. STEEL TOP ROLLER BRACKET (DOUBLE) _ FASTENED W/ (6) # 14 X 5/8" S.M.S. 090 THK. GALV. STEEL ADJUSTABLE SLIDE FASTENED TO BRACKET W/ 5/16-18 X 3/4' HEX HEAD SCREWS & NUTS. .o- " X 1-5/8' LAG SCREWS IWO WOOD OR 5/16" SLEEVE ANCHORS WITH 1-1/4" EMBED INTO MASONRY 3 PER BRACKET -1/2" X 4-1/4" X 13 GA. STEEL PLATES M TO 1-1/2' X 1-1/2" X 14 GA. ANGLE FASTENED TO TRACK WITH (4) 1/4-20 SS. BOLT & NUTS HORIZONTAL REINFORCEMENT LUED TO PAAN4EL*AND FASTENED TO• STEEL VERTICAL STILES WITH (2) 3/16' POP RIVETS 2" X 5-1/2" X .104" GALV. STEEL FASTENED W/ (4) # 14 X 5/8" S.M.S. TOP ROLLER BRACKET FOR LOW HEADROOM DOOR OPTION HORIZONTAL REINFORCEMENT 1/2' X 1-3/4" X .059" FORMED STEEL GLUED TO PANEL AND FASTENED TO VERTICAL STILES WITH (2) 3/16" POP RIVETS x5/16" MEETING RIB 1.82" DIA. X .50" ROLLERS W/ .44 DIA. X 4-1/4" STEM a_ N K 0 co 14 GA. GALV. STEEL ROLLER HINGES FASTENED W/ (4) #14 X 5/8' SMS MIN. .024" ROLL FORMED STEEL PANEL DRAWING QUALITY G-40 MIN. YIELD STRENGTH = 34 KSI WITH PRIMER AND BAKED -ON POLYSTER PAINTED TOP COAT APPLIED TO' BOTH SIDES OF STEEL 12 GA. GALV. STEEL BOITOM #BR4ACXKEST FASTMENSED _ BOTTOM SEAL .058 ALUM PLATE WCTH 1/8' X 1" us, a 48" D.C. SE�QNAA AND RUBBER WEATHERSTRIPPING. m u) m m m m m TRACK CONFIGURATION HORIZ. TRACK SUPPORT, CENTER SUPPORT REQD. ON DOORS EXflEEDING 8 FT. IN HEIGHT it A 1 TRACK LENGTH = OPENING HEIGHT PLUS 12" 14 GA. GALV. STEEL TRACK 2 X 2 X 1/8" HORIZ. ANGLE SPOT WELDED To HORIZ. TRACK WITH TWO WELDS AT 1-1/2' APART FIRST AT 3" O.C. REST AT 9" O.C. CONNECTED TO FLAG BRACKET ANGLE W/ 3/8-16 X 3/4" BOLT & NUT AND TO SPRING SHAFT GUIDE WITH (2) 1/4-20 X 5/8" BOLT & NUT VERTICAL TRACK" " X .080" SECTION A -A DOOR * SECTION HEIGHTS BRACKET PLACEMENTS OPTIONAL. INSULATIONS. HEIGHT IST 2ND 3RD 4TH 5TH B1 - BY 'DYPLAST PROOUCTS LLC' 84 IF B6 87 138 6'-0" EPS -EXPANDED POLYSTYRENE j 1" 11-3/4" 23" 34" DENSITY - 1.05 PCF 56" = 6'-6" 21" 18" 18" 21" N/A N.O.A. #07-1107.06 0 23" 34' 45" 56' OR POLY-ISOCYANURATE 7'-0" (�ISO-25 21" 21" N/A 1" 11-3/4" 23" m 45' 56" 67" - - DENSITY a 2.0 PCF 18" 18" 18" L 11-3/4" 23' 34"45" N.O.A. #07-40301.10 56" 67" 8'-0" 21-118-118- 18" 21" OR 'INSLIL.FOAM 11-3/4" 1 23' 1 34" 1 45" 56" W LLC' DENSITY = 0.92 ACF N.O.A. #07-1016.07 a_ N K 0 co 14 GA. GALV. STEEL ROLLER HINGES FASTENED W/ (4) #14 X 5/8' SMS MIN. .024" ROLL FORMED STEEL PANEL DRAWING QUALITY G-40 MIN. YIELD STRENGTH = 34 KSI WITH PRIMER AND BAKED -ON POLYSTER PAINTED TOP COAT APPLIED TO' BOTH SIDES OF STEEL 12 GA. GALV. STEEL BOITOM #BR4ACXKEST FASTMENSED _ BOTTOM SEAL .058 ALUM PLATE WCTH 1/8' X 1" us, a 48" D.C. SE�QNAA AND RUBBER WEATHERSTRIPPING. m u) m m m m m TRACK CONFIGURATION HORIZ. TRACK SUPPORT, CENTER SUPPORT REQD. ON DOORS EXflEEDING 8 FT. IN HEIGHT it A 1 TRACK LENGTH = OPENING HEIGHT PLUS 12" 14 GA. GALV. STEEL TRACK 2 X 2 X 1/8" HORIZ. ANGLE SPOT WELDED To HORIZ. TRACK WITH TWO WELDS AT 1-1/2' APART FIRST AT 3" O.C. REST AT 9" O.C. CONNECTED TO FLAG BRACKET ANGLE W/ 3/8-16 X 3/4" BOLT & NUT AND TO SPRING SHAFT GUIDE WITH (2) 1/4-20 X 5/8" BOLT & NUT VERTICAL TRACK" " X .080" SECTION A -A DOOR * SECTION HEIGHTS BRACKET PLACEMENTS HEIGHT IST 2ND 3RD 4TH 5TH B1 B2 B3 84 85. B6 87 138 6'-0" 18" 18" 18" 18' N/A 1" 11-3/4" 23" 34" 45" 56" 67" - 6'-6" 21" 18" 18" 21" N/A 1" 11-3/4" 23" 34' 45" 56' 67" - 7'-0" 21" 21" 21" 21" N/A 1" 11-3/4" 23" 34" 45' 56" 67" - 7'-6" 18` 18" 18" 18" 18" 1"' 11-3/4" 23' 34"45" 56" 67" 8'-0" 21-118-118- 18" 21" 1' 11-3/4" 1 23' 1 34" 1 45" 56" 67" 78-1/4" *-SECTIONS ARE NUMBERED STARTING AT THE BOTTOM FOR DOORS MORE THAN 8 FT. HIGH, USE ADDITIONAL TRACK BRACKETS AT 10" O.C. 1.9" X 2.19" X 3.3' X .090' STEEL TRACK BRACKETS 2-3/16" HIGH CONNECTED TO TRACK WITH 0) 1/4" BOLTS & NUTS. RVA -26 -ax! I I 1 0 MORE. i. CIVIL FL16 RE # 705J2 QXN. 3538 LOW HEADROOM DOUBLE TRACK pg+OpUCi' >tEV1,SED No 12— 16) "ka6mAP 0&92 m co O C3 O n o L j r,0 CO z � � _ m -j cn n I Z m O C7 u�y v O z ,� A M a drawing no. 01-09 WOOO FRAME BUIL GS STUD WALLS OR DOOR OPENING (NOT BY DAB DOORS) SHALL BE FRAMED SOLID BY NOT LESS THAN (3) 2X6 PRESSURE TREATED GRADE 2 SYP OR BETTER WOOD STUDS. STUD WALLS TO BE CONT. FROM FOOTING TO TIE BEAM. ENGINEER OF RECORD TO VERIFY ADEQUACY OF THE SUPPORTING STRUCTURE. yD BUCK CONNECTION TO MASONRY_ TRACK SHALL BE SECURED WITH CONT. STEEL ANGLE TO PRESSURE TREATED 2X6 SYP WOOD JAMBS WHICH SHALL BE ANCHORED TO GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WITH 1/4- ULTRACON BY 'ELCO' WITH SPACING OF 20" O.C. INTO BLOCK WALL, WITH 2-1j4" MW. EMBED 18" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4° MW. EMBED 2-_if_2" MAIC.- ZDGI<_ DISTANCE 1/40 TAPPER BY 'POWERS' WITH SPACING OF 14" O.C. INTO BLOCK WALL, WITH 1-11r MIN. EMBED 16" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4" MIN. EMBED 3" MIN. EDGE DISTANCE 3/8" CONFLEX BY 'ELCO' OR 3/8" LDT BY TW WITH SPACING OF 24" O.C. INTO 3000 PSI CONCRETE, WITH 2-1/2" MIN. EMBED 2" MIN. EDGE DISTANCE 3/8" HLC SLEEVE BY 'HILTI' WITH SPACING OF 17" O.C. WTO BLOCK WALL, WITH 1-1 4" MIN. EMBED, 4" MIN. EDGE DIST, 18" O.C. INTO 3000 PSI CONCRETE, WITH 1-1/4° MIN. EMBED AND 2-1/2" MIN. EDGE DISTANCE THE BLOCK WALL CELLS SHALL BE GROUT FILLED AND REINFORCED WITH FOUR # 5 BARS EXTENDING INTO FOOTING AND INTO TIE BEAMS ALL BARS SHALL BE CONTINUOUS FROM TIE BEAMS TO FOOTING. RRP�iION OF JAMBS BY OTHER JAMBS BY OTHERS 5/16" X 1-5/8" LAG SCREWS AT 12" O.C. 1-1/2" STEEL STRUCTURE BY OTHERS MUST SUPPORT THE LOADS IMPOSED BY DOOR SYSTEM ANCHOR SPACING o O a [] ANCHORS STRUCTURE EMBED SPACING EDGE DIST. 3/8" HLC SLEEVE BY 'HMI' CONC. 1-1/4" B" —03 3/8" HLC SLEEVE BY 'HIL71' FILLED BLOCK 1-114.' IA) EA O I 8" " 3/8" DYNABOLT BY '11W' CONC. 1_1/2,r8" 2- "3 318" 8" DYNABOLT BY 'ITW' FILLED BLOCK 1-1 2 S" 3-3/4" UB" POWER -BOLT BY 'POWERS' CONC. 1 2" 8" 1-7/8" 13/8- SLEEVE -ALL BY SIMPSONS' CONC. 11-1/2" 8" EU �� co I ti W rq Q a N c� Qo 0 0 M 0 o 0 (L 0 or' Q re c U.z�' J B 4WD it 00 CONCRETE f'c a 3000 PSI MIN. O O 3 5 16" DIA. BOLTS O .Z , Q o C-90• GROUT' FILLED BLOCK fm = 2000 PSI MIN. F u' U.., WITH WASHER & NUT W 0ZdQ o Lo AT 12" b.C. IMAX. EDGE DIST. � m � J " .- OQ • �z CONT. 4"SLL2-ANG�X 14 GA 12 GA. GALV. STEEL o n FLAT BRACKETS ::L3" LONG " �+ AT 12" O.C. IN DOOR OPNG, 0 AT 18" O.C. ABOVE DOOR OPNG. >° CONNECTED TO CONT. ANGLECL t 8 W/ (3) SPOT WELDS AT EACH SIDE 2-1/8" X 1" X 14 GA. Z GALV. STEEL. TRACK FASTENED TO TRACK PLATES W/ (2) 1�4-20X5/8" TRUSS HD. SLOTTED S. do LOCK NUT 'ryj n qa ro m �- 0 o M• o 'rji ALTERNATE TRACK INSTALLATION L co m c U O W ti pROD XT IRE V1M c c 9r VIi. O' a+ 1n8 WJ* ft Flo idd I FLA, PE 70592 CBudd .A.IJ. ;530 , 0�1 av a drawing fl r 01 o O a [] M Ld >� Ll z } En N —03 Q IA) EA O I CONCRETE f'c a 3000 PSI MIN. O O 3 5 16" DIA. BOLTS O .Z , Q o C-90• GROUT' FILLED BLOCK fm = 2000 PSI MIN. F u' U.., WITH WASHER & NUT W 0ZdQ o Lo AT 12" b.C. IMAX. EDGE DIST. � m � J " .- OQ • �z CONT. 4"SLL2-ANG�X 14 GA 12 GA. GALV. STEEL o n FLAT BRACKETS ::L3" LONG " �+ AT 12" O.C. IN DOOR OPNG, 0 AT 18" O.C. ABOVE DOOR OPNG. >° CONNECTED TO CONT. ANGLECL t 8 W/ (3) SPOT WELDS AT EACH SIDE 2-1/8" X 1" X 14 GA. Z GALV. STEEL. TRACK FASTENED TO TRACK PLATES W/ (2) 1�4-20X5/8" TRUSS HD. SLOTTED S. do LOCK NUT 'ryj n qa ro m �- 0 o M• o 'rji ALTERNATE TRACK INSTALLATION L co m c U O W ti pROD XT IRE V1M c c 9r VIi. O' a+ 1n8 WJ* ft Flo idd I FLA, PE 70592 CBudd .A.IJ. ;530 , 0�1 av a drawing fl r 01 N I 9 DOOR PANEL 24 GA. (.024) STEEL MIN. x7/16" DIA. WASHER #a X 3/4" SMS a 3/8" FROM ENDS AND 7" O.C. MAX. (4) #8 X 3/4" SMS .@ 1-3/8" FROM ENDS AND 6-1/2" O.C. MAX 175 X .062 DEEP 1/4" POLYCARBONATE LEXAN BY SABIC INNOVATIVE PLASTICS NOA JOS-0305.02. 175 X .062 DEEP GROOVE (4) #8 X 3/4" SMS ® 1-3/8" FROM ENDS AND 6-1/2" O.C. MAX. X 3/4" SMS 0 3/8" FROM ENDS AND 7" O.C. MAX. 7/16' DIA. WASHER DOOR PANEL 24 CA. (.024) STEEL MIN. #8 X 3/4" SMS 0 3/8" FROM ENDS AND 4-1/2" D.C. MAX.] DOOR PANEL 24 GA (.024) STEEL. MIN. * PLASTIC COMPLIES WITH SECTION 2612 OF FBC 2007 SEE EVIDENCE PAGE I i i I I' i I• 21 3/4" MAX. l WDW. WIDTH 18 1/8" MAX' ¢ o In 15/16" MIN. INSIDE ELEVATION RAISED PANEL. EMBOSSED DOOR WITH OPTIONAL WINDOWS .175 X .062 DEEP /—GROOVE I EXTERIOR 0_ co O O M Lij Q� Zvi c`dv 00 W to to M I F 0 w o T gr: JAVigD' rWMAD ' PJIGDJICT REV= �NMIPIYb* Oft FLA FECI # 7092 t+lreFlot�dr+ I Acbeptm+ea iVo % 0, 6 pal �di1 By l pmdlx�Ct+tdtot drawing no. 01-09 .250 q w z ^ 0 � h� m 1.755 1.725 1.144 IL ix Ov � rl or M EXTERIOR FRAME * INTERIOR FRAME a U) cc o RIGID PVC ONE PIECE.INJECTION RIGID PVC ONE PIECE INJECTIONuj N INSIDE ELEVATION RAISED PANEL. EMBOSSED DOOR WITH OPTIONAL WINDOWS .175 X .062 DEEP /—GROOVE I EXTERIOR 0_ co O O M Lij Q� Zvi c`dv 00 W to to M I F 0 w o T gr: JAVigD' rWMAD ' PJIGDJICT REV= �NMIPIYb* Oft FLA FECI # 7092 t+lreFlot�dr+ I Acbeptm+ea iVo % 0, 6 pal �di1 By l pmdlx�Ct+tdtot drawing no. 01-09