Loading...
CC-14-243C BUILDING PERMIT APPLICATION Miami Shores Village . , �111F-D Building Department JUL 29 2014 I 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 !� Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 k -b Master Permit No. CC — Z —/ il — Z* Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION SHOP CONTRACTOR DRAWINGS JOB ADDRESS: A &- 2 - City: City: Miami Shores County: Miami Dade Zip: 53 i6 l Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder):6 l'1t-)i�' Aj t(;4 1, � I Phone#: 3 L ,5 �% 7 Address: City: _ & I fat-Ai t) t S State: Tenant/Lessee Name: Email: Phone#: p: 35/(/ CONTRACTOR: Company Name: L -J-' 2/70 Phone#: Address: 12—j l v21tell lr 2-10 City: L% Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature_ ;�! ��f�a�r� Signature OWNER or AGENT The foregojng instrument was acknowledged before me this //�� 423 R day of �d 20 � , by AR. who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: t� l./a i` -• Print: Seal: **************** APPROVED BY l (Revised02i24i2014) CONTRACTOR The foregoing instrument was acknowledged before me this day of rr" 20 by �Ma*k fja-wytt who ' personall know to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: as Sign: iW rVF Print: leeA( u Notary Public State ofEFI.rlidaSeal: Rafael Huguet� = My Commission EE04 Tor r� Expires 01/24/2om Plans Examiner Zoning Structural Review Clerk • _ � ) LL z -J4 --zy3 Eastern Engineering Groyp `fZZE; 3401 NW 82nd Avenue Suite 370, Doral, F 3P1 2-105 •••• •6666. T 305.599.8133 • F. 305.599.8076 • www.easterrmg.com ... • � •. 600.09 0900.. . 6666.. . . . .60606 6666 .. 9 0 6 6 9 . 6 6 6666 . .. .6666 069690 .. .. 6666 996666 6666.. BarryUniversityCha 'el*064 .. 69666. 96 6 9999 9 Job No: 14-08tN7XCPTICNS ` A • !_. MARE CORRECTIONS NOTED Ej ANDRE.SUEMHT ❑REJECTED JUL 3 9 1014 Review is only for~nance with the design concept of the n :j ai con;plianre td�th the Railing various information d0curnents. Any ac CA `' ; shown is sul�::: meets of the plans ; specifications. Cc - ,,esr)onsibie for: Dinensi t is ich shall be r..: ;tt=r, ' :„;'A Lorrelated at the job si g,; 11300 NE 2ND AVE ricaticn prcc� SS I ^r�iques of construc` 0 !; rdination of,, tr 'all otf er trades and the OFtICEMIAMI SHORES, FL 33 ti�f toiypeo' ` ^n r . y K! AY LC copoy, D O Miami Sh®rns Foil , APPROVED BY DATFE 9 70NING DEPT BLDG DEPT - J SUBJECT TO COMPLIAN ITH ALL FE STATE AND COUNTY RULES AND RFGU1 Ai1 )NS Prepared By: ❑ Raissa Lopez, PE Lic. No. 59399 CAN # 26655 LCULA NS ta�y,aaoar�:;, .t PAZ GY•�cJ �. •` ,cam. ' CJ p1� `. .�. O .+J Y. j i' Pf” ElGonzalo racz PE Lic. No. 60734 CAN # 26655 NO. OF PAGES: 14 080 14 080 Barry University Chapel Page 1 of 16 • Project Name:14 080 Barry University Chapel 175.0 zt := 1,0 Kd := 0.8 L., = 0.8 Cf:= 1. 9.5' zg := 900.0 Date:03/11 /2014 • Height of Top of Sign (ft) Solidity Ratio of Sign (%) qz:= 0.00256•Kz•Kzt•Kd•V2 pz:= 0.6(gz G -Cf) E pz.EQ := mpz 100 '10 4 Eastern,�gyy eering Group 14 080 Barry University Chapel psf 00.000 0000.0 .00000 99900 0000. 999999 0 9 000000 99.999 0 0 Gross Wind per Actual Solid Area (psf) Equivalent Wind in Overall Area (psf) Page 2 of 16 0000 Miami Daae 9'Broward ." Category I...............V=165 mpA.* ..... =159 mph Category If..............V=175 m�hs.�.� =170 mph Wind Velocity (mph) Category III & IV ..... V=186 mpp,,,,,,..V=18Q 1np q Topographic Factor .000 . .. 09.00. 9 .. 09 00 9999 Wind Directionality Factor (see table 26.6-1) ASCE 7-10 .... Kd=Oz& 9 9 9 0 9 0000.. Gust Factor • 00 9 9999 9999 Net Force Coefficients Cf (see Figure 29.5-2) Flat -Side Members Rounded Members for s<=O.1 2.0 1.2 ------------- 0.8 for 0.1 to 0.29--------------------------------------- 1.8 1.3 ----- ------- 0.9 for0.3 to 0.7----------------------------------------- 1.6 1.5 ------------ 1.1 Values for Terrain exposure constants a and zg: Exposure B------ Value a =7, Value zg=1200 Exposure C------ Value a =9.5, Value zg=900 Exposure D------ Value a =11.5 , Value zg=700 • Height of Top of Sign (ft) Solidity Ratio of Sign (%) qz:= 0.00256•Kz•Kzt•Kd•V2 pz:= 0.6(gz G -Cf) E pz.EQ := mpz 100 '10 4 Eastern,�gyy eering Group 14 080 Barry University Chapel psf 00.000 0000.0 .00000 99900 0000. 999999 0 9 000000 99.999 0 0 Gross Wind per Actual Solid Area (psf) Equivalent Wind in Overall Area (psf) Page 2 of 16 • C7 Project Name:14 080 Barry University Chapel psi Fw 9000.0 psi Allowable stress for non welded members. Allowable stress for weld -affected members. Partial Welding, As per Aluminum Code 2005, section 7 Fpw = Fn — CArn/A)x(Fr)—Fw) Aweld = (2x(wd))xtw Aweld = 2)Kwd")Ktw A = (2sides))K(3c)X(tw)+b(tw) A = (3 c+b) X tw Date:03/11/2014 .0 0 wd rein length plus 4" at each end J—, w Aw:= 1.0 (times thickness ) weld -affected cross sectional area FC 1.0 in distance from neutral axis to extreme comp fiber. in post width. net cross sectional area of the compression flange of a beam, consisting Ac := 3 . c + b (times thickness ) of the portion of the section farther than 2c/3 from the neutral axis, where c is the distance from the neutral axis to the extreme fiber. Fps' := FN — A • (FN — FW) Ac 14 080 14 080 Barry University Chapel in — lb Page 3 of 16 14 080 14 080 Barry University Chapel Page 4 of 16 • 17J • DIMENSIONS AND PROPERTIES 1-99 14 080 14 080 Barry l�iversihr Chapel AMERICAN INSTITUTE OF TEEL ONS RUCTION, INC. Page 5 of 16 Table 1-14 • Pipe " Dimensions and Properties ••• ' 4 •'0"PIPE ****PIPE.. • • • •.•. • Nom- Dimensions _ Nominal Design • • • • ; ; • Outside Inside final Wall Wall Area D/t I S C• 0 Shape Dia- Dia- Thick- Thick - : • .I Wt meter meter ness ness Ib/ft in. in. in. in. in? in.4 in.3 & . 01g.4 1n 3 • .. , Standard Weight (Std.) 69% Pipe 12 Std. 49.6 12.8 12.0 0.375 0.349 13.6 36.5 262 41.0 4.39 523 53.7 Pipe 10 Std. 40.5 10.8 10.0 0.365 0.340 11.1 31.6 151 28.1 3.68 302 36.9 Pipe 8 Std. 28.6 8.63 7.98 0.322 0.300 7.85 28.8 68.1 15.8 2.95 136 20.8 Pipe 6 Std. 19.0 6.63 6.07 0.280 0.261 5.22 25.4 26.5 7.99 2.25 52.9 10.6 Pipe 5 Std. 14.6 5.56 5.05 0.258 0.241 4.03 23.1 14.3 5.14 1.88 28.6 6.83 Pipe 4 Std. 10.8 4.50 4.03 0.237 0.221 2.97 20.4 6.82 3.03 1.51 13.6 4.05 Pipe 31/2 Std. 9.12 4.00 3.55 0.226 0.211 2.51 19.0 4.52 2.26 1.34 9.04 3.03 Pipe 3 Std. 7.58 3.50 3.07 0.216 0.201 2.08 17.4 2.85 1.63 1.17 5.69 2.19 Pipe 21/2 Std. 5.80 2.88 2.47 0.203 0.189 1.59 15.2 1.45 -1.01 0.952 2.89 1.37 Pipe 2 Std. 3.66 2.38 2.07 0.154 0.143 1.00 116.6 0.627 1 0.528 0.791. 1.25 0.713 Pipe 11/2 Std. 2.72 1.90 1.61 0.145 0.135 0.750 14.1 0.293 1 0.309 0.6261 0.586 0.421 Pipe V/4 Std. 2.27 1.66 1.38 0.140 0.130 0.6L12.8 0.184 0.222 0.543 0.368 0.305 Pipe 1 Std. 1.68 1.32 1.05 0.133 0.124 0.4 0.0830 0.126 0.423 0.166 0.177 Pipe 3/4 Std. 1.13 1.05 0.824 0.113 0.105 0.3 0.0350 0.0671 0.336 0.0700 0.0942 Pipe 1/2 Std. 0.850 0.840 0.622 0.109 0.101 0.2 0.0160 0.0388 0.264 0.0320 0.0555 Extra Strong (x -Strong) Pipe 12 x -Strong 65.5 12.8 11.8 0.500 0.465 17.9 27.4 339 53.2 4.35 678 70.2 Pipe 10 x -Strong 54.8 10.8 9.75 0.500 0.465 15.0 23.1 199 37.0 3.64 398 49.2 Pipe 8 x -Strong 43.4 8.63 7.63 0.500 0.465 11.9 18.5 100 23.1 2.89 199 31.0 Pipe 6 x -Strong 28.6 6.63 5.76 0.432 0.403 7.88 16.4 38.3 11.6 2.20 76.6 15.6 Pipe 5 x -Strong 20.8 5.56 4.81 0.375 0.349 5.72 15.9 19.5 7.02 1.85 39.0 9.50 Pipe 4 x -Strong 15.0 4.50 3.83 0.337 0.315 4.14 14.3 9.12 4.05 1.48 18.2 5.53 Pipe 31/2 x -Strong 12.5 4.00 3.36 0.318 0.296 3.44 13.5 5.94 2.97 1.31 11.9 4.07 Pipe 3 x -Strong 10.3 3.50 2.90 0.300 0.280 2.83 12.5 3.70 2.11 1.14 7.40 2.91 Pipe 21/2 x -Strong 7.67 2.88 2.32 0.276 0.257 2.11 11.2 1.83 1.27 0.930 3.66 1.77 Pipe 2 x -Strong 5.03 2.38 1.94 0.218 0.204 1.39 11.6 0.827 0.696 0.771 1.65 0.964 Pipe 11/2 x -Strong 3.63 1.90 1.50 0.200 0.186 1.00 10.2 0.372 0.392 0.610 .0.744 0.549 Pipe 11/4 x -Strong 3.00 1.66 1.28 0.191 0.178 0.830 9.33 0.231 0.278 0.528 0.462 0.393 Pipe 1 x -Strong 2.17 1.32 0.957 0.179 0.166 0.600 7.92 0.101 0.154 0.410 0.202 0.221 Pipe 3/4 x -Strong 1.48 1.05 0.742 0.134 0.143 0.410 7.34 0.0430 0.0818 0.325 0.0860 0.119 Pipe 1/2 x -Strong 1.09 0.840 0.546 0.147 0.137 0.300 6.13 0.0190 0.0462 0.253 0.0380 0.0686 Double -Extra Strong (xx-Strong) Pipe 8 xx-Strang 72.5 8.63 6.88 0.875 0.816 20.0 10.6 154 35.8 2.78 308 49.9 Pipe 6 xx-Strong 53.2 6.63 4.90 0.864 0.805 14.7 8.23 63.5 19.2 2.08 127 27.4 Pipe 5 xx-Strong 38.6 5.56 4.06 0.750 0.699 10.7 7.96 32.2 11.6 1.74 64.4 16.7 Pipe 4 xx-Strong 27.6 4.50 3.15 0.674 0.628 7.64 7.17 14.7 6.53 1.39 29.4 9.50 Pipe 3 xx-Strong 18.6 3.50 2.30 0.600 0.559 5.16 6.26 5.79 3.31 1.06 11.6 4.89 Pipe 21/2xx-Strong 13.7 2.88 1.77 0.552 0.514 3.81 5.59 2.78 1.94 0.854 5.56 2.91 Pipe 2 xx-Strong 9.04 2.38 1.50 0.436 0.406 2.51 5.85 1.27 1.07 0.711 2.54 1.60 14 080 14 080 Barry l�iversihr Chapel AMERICAN INSTITUTE OF TEEL ONS RUCTION, INC. Page 5 of 16 • Project Name:14 080 Barry University Chapel Date:03/11 /2014 Allowable Stresses for Aluminum ; .'. •••• 6063-T6 6063-T5 6061-T6 05-T30. (psi) (psi) (psi) .:.•• (psi) ' Fb 15000 9500 19000 . ,.. 19000 (Tubes & Shapes) Fb 18000 11500 24000 9•••424000. .. (Round & Oval) Fv 8500 5500 12000 . .12000 • Tubes, Shapes & Round E 10100 ksi 10100 ksi 10100 ksi ��• 19100 ksi White bars apply to nonwelded members and to welded members at loc. fathers than 1.0 in from.alwl Shadded bars apply to within 1.0 in of a weld Allowable Stress for Aluminum Welding: Aluminum Filler Alloy 5356 F\=7000 psi Allowable Stress for Steel Strong and Weak Axis Allowables Stress for Tube Steel Shape: Fb=23760 psi, Fv=14400 psi for Fy=36 ksi E=29000 Ksi Fb=33000 psi, Fv=20000 psi for Fy=50 ksi E=29000 Ks Allowable Stress for Steel Welding: Welding: E-70XX Fv=21000 psi Allowable Stress for Stainless Steel Strong and Weak Axis Allowables Stress for Tube Steel Shape: Fb=16216 psi, Fv=9189 psi for (SS 304) Fy=30 ksi E=28000 Ksi Fb=24325 psi, Fv=13514 psi for (SS 304 1/16 Hard) Fy=45 ksi E=28000 Ksi Fb=40540 psi, Fv=22702 psi for (SS 304 1/4 Hard) Fy=75 ksi E=28000 Ksi Fb=59460 psi, Fv=30270 psi for (SS 304 1/2 Hard) Fy=110 ksi E=28000 Ksi Allowable Stress for Steel Welding: Welding: E318 or E309 Fv=19200 psi Allowable Stress for Wood Strong and Weak Axis Allowables Stress for Lumber No.2 Non Dense (2"-4" thick): Fb=1350 psi, Fv=175 psi for 2"4" Wide E=1400 Ksi Fb=1150 psi, Fv=175 psi for 5"-6" Wide E=1400 Ksi DESIGN INFORMATION: Florida Building Code 2010 AISC Manual of Steel Construction, NDS -ASD for Wood Construction, ASCE 08-07 Specification for the Design of Cold -Formed Stainless Steel Structural Members, Aluminum Design Manual 2005 Wind Loads, ASCE 7 - 10 DESIGN LOADS: Handrail Design Loads: Concentrated Load = 200 lbs. applied at any point in any direction. Uniform Load = 50 plf applied in any direction (other than dwelling units). Guardrail System Loads: Concentrated Load = 200 lbs. applied at any point in any direction at the top of the guardrail (other than dwelling units include a load of 100 lbs applied vertically downward at the top of guardrail). Concentrated horizontal load of 50 lbs applied on a 1 sq ft. area at any point in the system. 14 080 14 080 Barry University Chapel Page 6 of 16 Is • H,pos — - L moi" L ---� -- L — �- k= 46,0 Railing Span (in) Ham, := 36.0 Post Height (in) q,vina 10.0 Wind Pressure (psf) Vertical Load Horizontal Load p200 = 200.0 Single Concentrated Load (lbs) .....Railing P=200.00, Fence P=0.00 .. • • 9999 ....�. 450:= 59.5q Uniform Distributed Load (plf)......... Railing q=50.00, Fence q=0.00 �.•� ••• • 960.60 .. .0.000 pyo := 50.t7 Single Concentrated Load (lbs) .....Railing P=50.00, Fence P=0.00 000000 ; 9 9 9 9 0 9.99 .. 9999 .. 9999. � +- •• •• •66• •6966• FbTR := 19000.0 psi FbT := 19000.0 psi iPT:= 1600 psi •6696• • • :0.0:. 0 6 • •:' FYTR:= 5500.0 psiFVBT = 5000.0 psi FY -PT := 5000.0 psi • • • • • • ' • 0990 SxTR:= 0.30 Vertical Loads in3 Sy�T := 0.331 in3 SxPT := 0,55, in3 ATR := 0.75 'in'ABT := 0.6$7 1 in2 APT := 0.937` in2 SyTR ;= 91701Horizontal Loads in:Vertical Loads in IxTR := 0.29 in4 1xBT := 0.1051 in 14 080 14 080 Barry University Chapel Page 7 of 16 Concentrated Load = 200 lbs. Concentrated Load = 200 lbs. 14 080 14 080 Barry University Chapel Page 8 of 16 VTR.200:= P20dbs lbs Uniform Load = 50 elf VM50 := 0.6.I q2 �.L lbs For Wind Pressure twind Hpost VTRwind�=0.6..—.L . L lbs .... 144Z • • .... ...... VTR := max(VTR.200, VTR.50, VTR.wind) • IbE6 ; • • •••••• •• •••••• ISIO Bending Design For Horizontal Load: Section Modulus Required • • • • • • •"" ...•.• ... .. ....• MTR Sam ••.• in3FbTR •••••• • SYTR.min ,- • • • Bending Design For Vertical Load: Section Modulus Required • • • • • • ( IxTR MTR 1 In3 SXTR.min :- + II\ /II FbTR IXTR + IXBT Shear Design: Area Required 1.5• VTR in2 ATR.min := FvTR BENDINGYY.top := if (SYTR.min SYTR, °N.G° "OKE) 11 BENDINGxx.top := if(SxTR.min ? SXTR, °N.G° "OK I E MEMM SHEARtop := if (ATR.min ? ATR, "N -G" "OK" ) EM E 14 080 14 080 Barry University Chapel Page 8 of 16 • • Concentrated Load = 200 lbs. RPT.200 P200 Uniform Load = 50 plf RPT.50 := 1.1 qs5o • L 12 For Wind Pressure gwind RPT.wind := 1.1 I 144 Hp.,t• L RPT := max(RPTT.200, RPT.5o, RPT.wind) rHpost MPT := maXl max(RpT.2oo RPT.So)' Hpost> RPT.wind' 2 VPT RPT Bending Design: Section Modulus Required: MPT SPT.min FbPT Shear Design: Area Required: 1.5• VpT APT.min FVPT 14 080 BENDINGpost := if(SpT.min ? SxPT, "N.G" , "OK" ) SHEARpost if(APT.min > APT, "N.G" , "OK" ) 14 080 Barry University Chapel lbs lbs lbs int Page 9 of 16 • For Wind Pressure 1 max(25,q ,;nd) Hpost 2 MBT.wind 8 ( 144 2 L tl`t,„ in — lb MBT := max(MBT.wind).. ft— lb For Wind Pressure 1 max(25,gw;nd) Hpost VBT.wind := 2 •( 144 ) 2 L t,���lbs VBT:= maX(VBT.wind) lbs SHEARbottom if(ABT.min > ABT, "N.G" , "OK" 14 080 14 080 Barry University Chapel Page 10 of 16 Bending Design For Horizontal Load: Section Modulus Required: .— MBTg�E SYBT.min i �"� in3 •— FbBT .:, - �'�164't,'��` a • • • • • • Bending Design For Vertical Load: Section Modulus Required: •••••• •• •••••• oo* •0*00 • MTR IXBTY, SXBT.min :_ �8 �I efCli "d , in • • FbBT IXTR + IXBT y, : • •. • • • • • • • Shear Design: Area Required: • • • • • •.. VBTt', ABT.min := Int • • • • • • FvBT •..• • • O „Ytt Ed S "N.G" "OK") BENDINGyy.bottom:— if(SYBT.mIn — >YBT — > , I BENDINGxx.bottom:= if(SXBT.min > SxBT, "N.G" , "OK" ) SHEARbottom if(ABT.min > ABT, "N.G" , "OK" 14 080 14 080 Barry University Chapel Page 10 of 16 • • MIA PERE Allowable Stress of Welding (psi) ElWidth of Tube Aluminum (in) t,:= x <- 0.00001 max(VBT) while >_ FVweld 0.707•b•x x E- x + 0.0625 Aweld b-te max(VBT) fV�,eld :- Aweld STRESS :="N.G." "OK" if FVw ld > fVweld t Wweld:= "1/8" if--Le--<-0.1250 e <_ 0.1250 0.707 "3/16" if 0.1250< t e <_ 0.1875 0.707 " 1/4" if 0.1875 < t, <_ 0.25 0.707 14 080 14 080 Barry University Chapel .2 in 0000 • 0000 0000 • 0000.. 0000 Page 11 of 16 0000.• • • • 0000.• 0000.. 0000• 0000• •000.0 0000.. 0000.. .s • 0 Rvertical �- D.grout I ( B.post B.grout � F1 D.post Post Width (in) Post Depth (in) des 4 p Post Embedment (in) Minimum Edge Distance (in) Equivalent Grout Width (in) Equivalent Grout Depth (in) Grout Strength (psi) Concrete Strength (psi) Id, :='3.0 Hold diameter (Grout Diameter) (in) 14 080 14 080 Barry University Chapel Page 12 of 16 • • • • 0 •.•..• •• 00000• • • • 0000 .. . • • . 0 . 0000 . .. 00000 . 0000.. 0 .• 000.0 • . . ..•... . . . .000..0 . 0000.. . ••.... .. . ••0• Page 12 of 16 ha ='6.0 Concrete Slab Deep (in) Pd := MPT lbs Hpost 2•hef 2+ 3•Hp".hef a:= in 3. he + 6.Hpost Pd. a2 P2 _ lbs hef. (2-a — hef) • Pl := P2 — Pd MINN lbs • 14 080 14 080 Barry University Chapel Page 13 of 16 9999 9999 9999.. .. . ...go Mextemal:= Pd'(Hpost + a) 9999... .. 1 9 lbs — in 900000 000 0000 • • . • • ...• • •. .99.9 ••..• . 90 ••i.•• Mintemal:= P2 P1.3•(hef — a) 4:.. - .....• 3•a+ itt!i •:9•:lbs— • •..•.• • • •••••• go Vu:= 1.6•(max(Pl>P2)) �aiF,ti �•.� : lbs .•.. :••.•: • 14 080 14 080 Barry University Chapel Page 13 of 16 2•P2 f2. out 1.6• psi a'Bpost 2.P1 fl.grout := 1.6• psi (hef — a)•Bpost Fpgrout:= [0.65•(0.85fcg,.o„)]•1.5 a psi .. � � �...._. �,,.... 14 0000 2•P2 f2. out 1.6• psi a'Bpost 2.P1 fl.grout := 1.6• psi (hef — a)•Bpost • Fpconcrete [0.65•(0.85•fcconcrete)]-1.5 tressconcrete := N• "O.K." if max(fl.concrete, f2.concrete) < Fpconcrete 14 080 14 080 Barry University Chapel psi Page 14 of 16 Fpgrout:= [0.65•(0.85fcg,.o„)]•1.5 a psi Stressg,out :_ "N.G." "O.K." if max(fl.grout,f2.grout):!�Fpgrout 0000 . . 0000 0000.. s nal tW� CI Gr(*t i d C i1e .. ...00 . 0000•• 00 0000.• • •00000 • • • •0.00• 2 P2\ 0000 .. • •• • • f2.concrete �= 1.6 •000 psi . 00 •0 . • 0• • a'Bgrout .•00 . • •0 0000• • • •. •• • . • 0000 0000.• • 0000.• • • • 2.P1 0 i • • •. •.. • fl.concrete:= 1'6 6;hh psi p ...000 • (he — a)'B . • • . • • 0000•• l grout .• . 0000 • • 0000• • Fpconcrete [0.65•(0.85•fcconcrete)]-1.5 tressconcrete := N• "O.K." if max(fl.concrete, f2.concrete) < Fpconcrete 14 080 14 080 Barry University Chapel psi Page 14 of 16 • Avco := 4.5 -Cal 2 int Ave:= 2 -(1.5 -Ca,) -ha if ha<1.5•Cal int 2•(1.5•Ca1)•(1.5•Cal) if ha>_ 1.5 -Cal ed.v 1•d Modification factor for edge effect F,,T7=--1.4-q Modification Factor in No cracked concrete at service loads yfc.v=1.4 Modification Factor in cracked concrete with yc.v=1 w/ No supplementary reinforcement. Wc.v=1.2 w/ Supplementary reinforcement of a No 4 Bar between the anchor and the edge. y,c.v=1.4 w/ Supplementary reinforcement of No 4 Bar and stirrups spaced at not more than 4 in. 0 BREAKOUTshear if(Vu > -�• Veb, "N.G." , "OK" 14 080 14 080 Barry University Chapel Page 15 of 16 I':= if`hef > 8•do'8•do'hef) in Y • •1•�•• •• ••••rr•• • Y;,•" 0 7 e0.2 l �do. onc-Cai1.5 rete lbs. `, i 0 • do • i••••i Ave • •• • e ••••• Vcb•— _ , I, •�ed.V•wc.V'Vb Ib� • +••e• •••e•• AV � • co •••••• • • ;= 07- Conditions lbs. •. • • • 0=0.75 w/ Supplementary reinforcement are crossing ••00 concrete failure prism. 0=0.70 w/ No supplementary reinforcement are crossing concrete failure prism. 0 BREAKOUTshear if(Vu > -�• Veb, "N.G." , "OK" 14 080 14 080 Barry University Chapel Page 15 of 16 • • Calc Cal "N/A" if ha < Cal r2 'Calc�' C Dgront + Bgont Acone.total= 2 2l a ' .,:. fQr: rd #WPas;: . 2 •_ � CBgreutl 7r one.post •— 2 Acone.total — Acone.post Acone.fina] �— 2 Vcone.cb 4• fCconcrete-Acone.final 0, Conditions �=0.75 w/ Supplementary reinforcement are crossing concrete failure prism. �=0.70 w/ No supplementary reinforcement are crossing concrete failure prism. BURSTOUTshear = if(VU > -�• Vcone.cb, "N.G." , "OK" 14 080 14 080 Barry University Chapel 2 in a in lbs Page 16 of 16 0000•• • • 0000•• • a 0000•• 0000•• •• 2 gy.m :: 0000•• •• • 0000•• • . .. • .... ..... . . lbs •0.000 • • • 000* lbs Page 16 of 16 0000•• • • 0000•• • a 0000•• 0000•• M9z��,7,�"- az M •� 1. ALL WORK SHALL CONFORM TO FLORIDA BUILDING CODE 2010. 2. IT IS THE INTENT OF THESE DRAWINGS TO BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND APPLICABLE CODES SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. EXISTING UTILITIES SHOWN ARE BASED ON INFORMATION SUPPLIED BY OTHERS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO MEET WITH ALL APPLICABLE UTILITY COMPANIES TO VERIFY ALL UNDER- GROUND FACILITIES PRIOR TO THE BEGINNING OF CONSTRUCTION. ALL EXCAVATIONS SHALL PROCEED WITH EXTREME CAUTION AT ALL TIMES. IN THE EVENT THAT EXISTING UTILITIES ARE DAMAGED, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPAIR OR REPLACE ALL DAMAGES. 4. THIS WORK REQUIRES A BUILDING PERMIT. DO NOT BEGIN WORKING UNTIL A BUILDING PERMIT 15 OBTAINED. 5. CONTRACTOR 15 TO FURNISH ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT NECESSARY TO COMPLETE ALL WORK SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. 6. DO NOT SCALE DRAWINGS, DIMENSIONS GOVERN. 1. ENGINEER'S VISITS TO THE SITE, AS PER G.0 OR OWNER'S REQUEST DURING CONSTRUCTION SHALL BE SCHEDULED WITHIN 24 HOURS PRIOR TO INSPECTION. 8. THE CONTRACTOR SHALL MAKE REQUIRED ARRANGEMENTS, SECURE AND PAY FOR ALL BARRICADES, ENCLOSURES, AND FENCING AS NEEDED FOR AND DURING THE PROGRESS TO PROTECT ADJACENT PROPERTIES. 9. THE CONTRACTOR SHALL NOT PROCEED WITH ANY ADDITIONAL SERVICES OR WORK WITHOUT PRIOR NOTIFICATION TO THE OWNER. 10.THE CONTRACTOR IS SOLELY RESPONSIBLE FOR MEANS AND METHODS CONSTRUCTION, AND FOR THE SEQUENCES AND PROCEDURES TO BE USED. 11. EXISTING GRADES WERE TAKEN FROM THE BEST AVAILABLE DATA AND MAY NOT ACCURATELY REFLECT PRESENT CONDITIONS. CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING WITH CURRENT 51TE CONDITIONS, AND SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER PRIOR TO STARTING WORK. ll. EASTERN ENGINEERING GROUP H45 EXCLUSIVELY DESIGNED THE STRUCTURE AND/OR BUILDING COMPONENTS IN COMPLIANCE WITH THE APPLICABLE EDITION OF THE FLORIDA BUILDING CODE AND DESIGN STANDARDS FOR STRUCTURAL REQUIREMENTS ONLY.THE EXISTING STRUCTURE MUST SUPPORT THE LOADS IMPOSED BY THE SYSTEM OR SYSTEMS. ENGINEER ON RECORD OF THE BUILDING OR CERTIFIED PROFESSIONAL ENGINEER SHALL VERIFY THE STRUCTURE FOR SUCH LOADINGS. I8. ELEMENTS WILL BE AS DESIGNED BY EASTERN ENGINEERING GROUP AND AS APPROVED BY ARCHITECT AND/OR OWNERS, TO CONFORM GENERALLY WITH THE ARCHITECTURAL DRAWING AND SPECIFICATIONS. 19. CODE FLORIDA BUILDING CODE, 2010 EDITION LOADS: RAILING: P=CONCENTRATED LOAD OF 200 S IN ANY DIRECTION AT ANY PLACE OF TOP MEMBER. W= DISTRIBUTED LOAD OF 50 PLF AT TOP MEMBER WIND LOAD AS PER ASCE 1-10 KD = 0.85, CATEGORY 2 WIND LOAD AS PER ASCE 1-10 WIND VELOCITY AS PER ASCE 1-10 KID =0.85 MIAMI -DARE BROWARD CATEGORY I ------------- 165 mph ------------156 mph CATEGORY 2 ------------- Il5 mph ------------110 mph CATEGORY 384 ------------- 186 mph ------------180 mph 20. THE EXISTING STRUCTURE MUST SUPPORT THE LOADS IMPOSED BY THE SYSTEM OR SYSTEMS. ENGINEER ON RECORD OF THE BUILDING SHALL VERIFY THE STRUCTURE FOR SUCH 21. THE QUANTITIES AND DIMENSIONS SHOWN ON THE DRAWINGS ARE BASED ON THE ARCHITECTURAL DRAWINGS. 22. ALL DIMENSIONS TO BE SITE VERIFIED. 12. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS AT THE JOB SITE. ANY DISCREPANCIES BETWEEN PLANS, SECTIONS AND DETAILS OR THE APPLICABLE CODES 1 OR REGULATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR ENGINEER DURING BIDDING OR BEFORE WORK BEGINS IN ORDER TO CLARIFY THE REQUIREMENTS AND TO EFFECT THE NECESSARY MODIFICATIONS, CHANGES AND /OR INSTRUCTIONS. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR RESETTING ALL DISTURBED EXISTING CONDITIONS AND PROPER DISPOSAL OF ANY EXTRA MATERIALS 8 GARBAGE FROM THE SITE AFTER COMPLETION OF WORK. 14. DRAWINGS AND DIMENSIONS ARE BASED UPON DRAWINGS SUPPLIED BY THE CLIENT. EASTERN ENGINEERING GROUP WILL NOT BE RESPONSIBLE FOR ERRORS OR MISINTERPRETATIONS OF THE SYSTEM DESIGNED BY US BASED ON CLIENT CONFIRMED DESIGN AND DIMENSIONS. ADDITIONAL DRAFTING TIME EMPLOYED IN THE CHANGE OF THE DESIGN AFTER SIGNING AND SEALING OF DRAWINGS WILL RESULT IN ADDITIONAL COST. 2 15. DO NOT SUBSTITUTE MATERIALS, EQUIPMENTS OR METHODS OF CONSTRUCTION UNLESS SUCH SUBSTITUTIONS OR CHANGES HAVE BEEN APPROVED IN WRITING BY THE OWNER. 16.EA5TERN ENGINEERING GROUP HAS GENERATED THESE SHOP DRAWINGS BASED ON A PROVIDED DESIGN THAT HAS BEEN DEVELOPED BY A LICENSED ARCHITECT OR A COMPETENT LICENSED DESIGN PROFESSIONAL WHO CONFIRMED COMPLIANCE WITH ALL APPLICABLE NATIONAL AND FLORIDA BUILDING CODES. 3, 1u t Irl 1�� I ALUMINUM SHALL MEET THE FOLLOWING REQUIREMENTS UNLESS NOTED OTHERWISE OR.T.4E: DRAWINGS: TYPE Fb Fb(WELDED) Fv FV(WELDED) 6063-T5(TU5E5 8 SHAPES) 9.5 KSI 4.8 K51 5.5 K51 2.8 KSI 6063-T5(ROUND4 OVAL) 11.5 KSI 5.5 K51 5.5 K51 2.8 KSI 6063-T6(TU15ES 8 SHAPES) 15.0 KSI 4.8 KSI 8.5 KS 2.8 KSI 6063-T6(ROUND 8 OVAL) 18.0 K51 5.5 K51 8.5 KSI 2.6 KSI 6005-T5(TUBE5 8 SHAPES) 19.0 KSI 8.0 K51 12.0 KSI 4.5 KSI 6005-T5(ROUND 8 OVAL) 24.0 KSI 9.0 KSI 12.0 KSI 4.5 KSI 6061-T6(TU5ES 8 SHAPES) IS.0 KSI 9.0 KSI 12.0 KSI 5.0 KSI 6061-T6(ROUND 8 OVAL) 240 KSI 10S KSI 120 KSI 50 KSI WELDING: ALUMINUM ALLOY.535. CLEANING: 65PC-SP2 'HAND TOOL CLEANING'. PAINT ALUMINUM AND STEEL HOT GALVANIZED SURFACES IN CONTACT WITH CONCRETE UITH ALKALI -RESISTANCE COATINGS, SUCH AS HEAVY -BODIED BITUMINOUS PAINT OR WEATHER -WHITE METHACRYLATE LACQUER. 4. ISOLATE DISSIMILAR METALS AS PER FBC 2010, SECTION 2003.8.4 Z � o W � h ? CLR 8 � z) - ZO �f W � N. ct z L Q W 0 W gra z m > O Z elm o � 1 X4/7 2014 SD -0.1 J • as9 • • � L O Y • . 2! 5 1 > a •qjj M c -v c Z cc ca • cce a i • s •• m U U Uo <=W 1 X4/7 2014 SD -0.1 A PARTIAL PIAN SD-I.m SCALE: 1/4"=1'-0' • 0000•• • 000.0• 0000 •! 0000 • i• ��aH=<mW� 82 NNYM ..o ❑ sfo. ... 4/7/2 IGSD-1.0 1 SECTION D -2.m SCALE: 1/4'=1'-0" rk PARTIAL PLAN D-2. SCALE: 1/4'=1'-O" ri� SECTION D -2.O SCALE: 1/4'=1'—m' h. I5"lI -s. I"xl'1l =�3 q4112014 SD -2.0 •••• W • c y co _ Z � •••••• •C13 J a • • N LY •• m d h. I5"lI -s. I"xl'1l =�3 q4112014 SD -2.0 ALUMINUM TUBE 2"X2'XJs' (ALLOY 6061-T6) ALUMINUM PIPE 0 ly'STD 40 (ALLOY 6061-T(o) ALUMINUM TUBE 2 "Xl'Xys' (ALLOY 6061-T(o) EXISTING CONCRETE SLAB -SECURED •. c SECURED TO CONCFEM WALLW t" 5463077{ PANTED smcw misH (7YF.) IM innnrtaen�nnnnmmnafltr6A. - Bi 1, Z 1 /7%" ALUMINUM TUBE 34"X3/4'>V (ALLOY 6061-T6) 6 A SECTION ".) SP -30 SCALE: 1/2"=1'-0' I rs-n-PIPERAIuw PNwrm N 12 1 RAMP SECTION SD -30 SCALE: 1/2"=1'-0' 3 ' DIAM. CORE DRILL 4.5" DEEP, UJ/ 4" MIN. EDGE DIST. TO EDGE OF CONCRETE, SET POST IN NON -SHRINK S 10000 PS I GROUT (TYP.) ALUMINUM PIPE 0 12'STD 40 (ALLOY 6061-T(o) ALUMINUM TUBE 3/4'X3/4'Xi/s' (ALLOY 6061-T6) ALUMINUM TUBE 2"X2"X%'s' (ALLOY 6061-T(o) ALUMINUM TUBE 3/4'X34"Xy9" (ALLOY 60(o1 -T6) ALUMINUM TUBE 3/4"X3/4"XYs" (ALLOY 6061-T(o) ALUMINUM TUBE 2"XI'XYs' (ALLOY 6061-T(o) c.v�vc.Kt i t B/SD-3.0 SLAB 1 SECTION SCALE: I'=1'-0' ALUMINUM TUBE 2'2"X/Vs` (ALLOY 6061-T(o) B DETAIL, Sp -30 SCALE: 3'=1'-0' C DETAIL 6D -3D SCALE: 3"=1'-0' C7 W M Z W ul OJ Z O QNo "' `° W iY � R t W M C Q W 0 mN> o N 6o2= =V 0 i D N (TYP.) 4/7/ 014 SD -3.0 t Engineering Group Miami Shores Village I K , -_7 Building Department JUL 2 8 2014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 i Tel: (305) 795.2204 Fax: (305) 756.8972 BY' INSPECTION'S .PHON : (305) 762.4949 S, REV ON FBC 20 [AD BUILDING Permit No. PERMIT APPLICATION Master Permit No. CC— Z _ j `f 3 Permit Type: C BUILDING ROOFING JOB ADDRESS: _ l 13 (3 U A) v E. 2 A04z , . C iOAEL City: Miami Shores County: Miami Dade Zip: ,3 5 I Folio/Parcel#: Is the Building Historically Designated: Yes ' NO Flood Zone: OWNER: Name (Fee Simple Titleholder): 1 '�/4 t, I rL t� 4= C.S i � Phone#:.3t S ., F,4 c/ --'? 7 fG Address: 11.3 c 6 . 2- zu'L- City: 1 S hl c G�L._S State: _ �..� Zip: 33 fE; r" Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: E%Lit.T�a C,�`Y Phonek quy — Address: [ Z) f S i r/ AV t; C 4 6 City: D1 i, ,A a 4---4c-}� State: i - Zip: el Qualifier Name• Phone#: State Certification or Registration #: C 6; G 1 . 1 2?V 7-J Certificate of Competency #: Contact Phone#: 7JS''ir 2-5-1 L 3;j / Email Address: )24r'. t(- ° CZMQ�lu Loi t�(?dc ic_rri c:�^rs9 DESIGNER: Architect/Engineer:.Sf+/4%) L_ LL-14.uit- Phone#: Value of Work for this Permit: $ 4q18'q .. 0 V Square/Linear Footage of Work: Type of Work: OAddition OAlteration ONew ORepair/Replace ODemolition Description of Work: PZL--"lT ! S / b A) 7Z) S C. , iA 4 yq)LjAAA4y0,v 72% /&/—I Color thru tile: ***************************************Fees******************************************** Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (if applicable)..... AZ Mortgage Lender's Address City State ;Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature Owner or Agent Contractor The foregoing instrument was acknowledged befor me this_i dayof, 20, by 1 who is personally known to me or who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: 1��112 /IFN My Commission Expires: APPROVED BY A J.'06 `� �� •�N,1SSIpN� •� • co NFF 113990 t J •. r Baided�AL�P: tL moi.. � • ^- The foregoing instrument was acknowledged before me this day of 20 , by W",yk- L & to , who i persona ly known t me or who has produced as identification and who did take an oath. Examiner Structural Review (Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) NOTARY Sign: Print: My Commission itItr, Uel Rafael Huguet My Commission EE042455 Expires 01/2412015 ********************************* Zoning Clerk