RF-14-2575Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-225797 Scheduled Inspection Date: December 30, 2014 Inspector: Rodriguez, Jorge Owner: MEMON, MUHAMMED AND IFTIKHAR Job Address: 309 NW 111 Terrace Miami Shores, FL 33168-3341 Project: <NONE> Contractor: MIAMI ROOFING SYSTEMS INC tiuiming uepartment comments RE -ROOF TILE AND FLAT Permit Number: RF -11-14-2575 Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile/Flat Phone Number Parcel Number 1121360010390 INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-223812. Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. December 29, 2014 For Inspections please call: (305)762-4949 Page 18 of 32 RE: Permit # ►` F -11-I `t -25' 7 5 XWf d S�Ma 1109ge ve4V Cfl=6aeat 10050 NE 2nd Ave Miami Shores, FI 33138 Phone 305.795-2204; Fax 305-756-8972 www.miamishoresvillage.com DATE: INSPECTION AFFIDAVIT I �GlV+2 v 2 IvICaY+'Z licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) License #: On or about FS 468 Building Inspector I did personally inspect the roof deck nailing and/or (Date & time) --II secondary water barrier work at `meq N 11 TeY I(i foryt1 flioye5 (y (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Manual (Based on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of Notary Public, Sate of Florida at Large e ' . *General, Building, Residential, or Roofing Contractors or any individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection FLORIDA TEC PROVIDING SOLUTIONS TO THE ROOFfNG INDUSTRY Lab Report No. 123754 C.A. # 30448 Lab Certificate # 13-0507.02 CONCENTRATED UPLIFT LOAD TESTING ON ROOF TILE TO COMPLY WITH METRO-DADE COUNTY PROTOCOL TAS -106 PROPERTYADDRESS• 309 NW 111"Terrace, Miami Shores PERMITNo. RF -11-14-2575 owNER IfMchar Memon ROOFING SQUARES:• 23 CONTRACTOR: Miami Roofing ROOF PITCH.• 3:12 TILE TYPE: Double Roll INSPECTOR INPfL4LS AB ATTACHMENT.• Poj*am TEST DATE.• 12/22/2014 Tastinn Fnninmant• ninital f `hotiunn nFiC Inn Tnet TnhulnHnn o- C... oc It.. THIS ROOF HAS: PASSED ® FAILED Q THE STATIC UPLIFT IN ACCORDANCE WITH MIANH-DARE COUNTY TAS 106. 23 24 \ ^_ /2s I 21 27 j i 28 32 I — �33 i I 29 31 50' 19 — — — — — — /35 i 1830 19 8-- I 11 38 —.7 17 \ 3 �� J / 13 1y \ 6- 16/ /5 1\ ' 14 Alberto Cardona, P E. Lie. No. 17138 IZ`, ?,.5 - i if 10735 SW 2161' St. Unit 416 Miami FL 33170 Page 1 of 1 www.FloridaTEC.net Tel: 305-256-4550 Fax: 305-256-6833 BUILDING PERMIT APPLICATION Miami Shores Village21 °' Building Department NOV 0'4 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 t3 y. Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 (�3 Master Permit No. IlI Sub Permit No. BUILDING Q ELECTRIC IN ROOFING ❑ REVISION p EXTENSION pRENEWAL PLUMBING M MECHANICAL PUBLIC WORKS M CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 309 NW 111 TER CRY, Miami Shores County Miami Dade Zia: - Follo/ParCeW.11 2136-001-0390 Is the Building Historkally Designated: Yes NO Occupancy Type: Load: Construction Type: J Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): Jl. I,tIrli1✓ Phone#: Address: 309 NW 111 TER City: MIAMI SHORES State: FL Zip: 3316$ Tenant/Lessee Name: _- Phone#: Email: CONTRACTOR: Company Name: MIAMI ROOFING SYSTEMS,INC Phone#: Address: 667 NW 101 ST City: MIAMI State: FL Zip: 33150 Qualifier Name: JAVIER R MARTINEZ Phone#: 305 754-5554 State Certification or Registration #: C' G C_ (—%) S &�) 2-2Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State Zip: Value of work for this Permit: $ 16. 1 q0 , `N Square/Linear Footage of Work: rrr--110 Type of Work: ❑ Addition ❑ Alteration Q New IN Repair/Replace Lt Demolition Description of work: Tear off existing roof systems down to a workable surface wood, install #30 felt install new 3x3 aaly. install file Specify color of color thru tlle:, Aj ins, ,. 6m iLr s. "i- s --Submittal Fee $ Permit Fee $ .&D CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $° Structural Reviews $ Bond $, �% tbo `o - TOTAL FEE NOW DUE $ I q 3 a (Re*ed=4/2024) I N Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or Installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. 'WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR LAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien Mia brochure will be delivered to the person whose property is subject to attachment Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is Issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing Instrument was acknowledged before me this day of W- QM Q1 .20 1% . by ihQY MetnOn who is personally known to me or who has produced Q. L as identification and who did take an oath. NOTARY PUBLIC: Signature CONTRACTOR Theforegoing instrument was acknowledged before me this day of W\ P.ibft, . 20 14 . by Javier R Martinez 11 is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Print: Seal: * = Notary Public - Sbttoftlorlda sot, 1 Q My Comm. Expires Ap 2016 41,'fp, V11- Commission # EE 183833 �####ffi######ffi#####ffi###ffi#ffi##ffi#####ffiffi###ffi######## APPROVED BY AV —LPlans Examiner (Revisedo2/24/2014) Zoning Structural Review Clerk Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: T - - � i k kc. -r M&na ac) Properly Address: 3 ®C( u CJ i i ( Tu - Roofing Permit Number: Date: /1/ 7-4 i ( c f Dear Building Official: I 17t'l certify that I am not required to retrofit the roof to wall connections of my building because: Ii The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is. prey me Toned. � 1P'�v PV °•, CARL SPI A Sworn to and subscribed before me this 2 d o �� =i:•".Jbtary Public - State of Florida N • t My Comm. Expires Aug 16.20 1 e Commission # FF 142787 •$total a Notary Public, Sate of Florida at Large When the just valuation of the structure for purpose of ad valorem taxation Is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a bulding application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. o -,6.A — Gni nMo Section MIAMt•DADE Miami -Dade County HVHZ "Delivering Excellence Every Day' Section A (General III Master Permit No: Process No: Contractors Name: MIAMI ROOFING SYSTEMS,INC Job Address: 1309 NW 111 TER Roof Category �r i�1-255 i Miami Shores Village I al r mal ZDATM,t D DEEPT DATE % I 1 W-4 TO COMPLIANCE WITH ALL FEDERAL STATE AVD COUNTY RULES AND REGULATIONS ✓❑ Low Slope ❑ Mechanically Fastened Tile✓❑ Mortar/Adhesive Set Tile ❑ AsP haltic Shingles ❑ Metal Panel/Sh' les ❑ 11.' ❑ Sprayed Polyurethane Foam ❑ Other.. Roof Type ❑ New Roof ❑ Re -Roofing ❑ Recovering ❑ Repair ❑ Maintenanc ' Are there Gas Vent Stacks located on the roof? ❑ Yes Q No If yes, what type? Nab LP Roof System Information Low slope roof area (ft?) 231 71 Steep Sloped area (ft.a) 2294 Total (ft.2) 2525 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, dearly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (al: Corner Size (a' x a7: X9.3 ��y1®may' /y � . .. \Y1 6666.. 666 6. . . 6666.. `- 666:6. NOV 21 2014 1�. F�aT Ia' 6666 .. :6666. 6666 .. 6666. BY.66660. 6666 6666. •• •• 9900 ••909• a � 0*000 . 6. . . . 6666.. ^ • . 666.. • •0 • 6666 6.00 5 S' r . Scction C I Miami -Dade County HVHZ Electronic Roof Permit Form M IAM I-DAOE <r Section C Page (Low Slope Roof Systems) ,. .+:�1,::1+•' qdl� M.:6eRt.��IY` d71T.:7jtSi7Lt+r.',+. Ir 3 C: •7Cr 7J}ttPieYPd 15 P)Gl fuselt not ajopljc'ii ii, +a ai de iri i'. YEA: f)t7 . ROOF SYSTEM MANUFACTURER: I FIRESTONE Product Approval (NOA): 11-0119.09 System Type: BUR Wind Uplift Pressures, From RAS 128 or Sealed Calculations: (131) Field: -42.8 psf (132) Perimeters: psf (133) Corners: "108 psf Maximum Design Pressure From NOA: -52.5 psf Roof Slope: 1/4 " : 12 Roof Mean Height: 12 ft. Parapet Walls: 0 No 0 Yes Parapet wall Height: ft. Deck Type: —5/8" Plywood— Support Spacing: N/A " o/c Alternate Deck Type: I N/A Existing Roof: N/A Fire Barrier: N/A Vapor Barrier: N/A Anchor Sheet: N/A Anchor Sheet Fastener/ Bonding Material: N/A Insulation Base Layer Size & Thickness: N/A Insulation Base Layer Fastener/ Bonding Material: N/A Insulation Top Layer Size & Thickness: N/A Insulation Top Layer Fastener / Bonding Material: N/A Base Sheet(s) & No. of Ply(s): 2 PLY OF FIRESTONE MB BASE Base Sheet Fastener/ Bonding Material: MECHANICALLY FASTENED 1 1/4 RS NAILS,* Ply Sheet(s) & No. of Ply(s): N/A Ply Sheet Fastener/ Bonding Material: N/A Top Ply: 11 PLY APP 180 FR Top Ply Fastening / Bonding Material: TORCH Surfacing: N/A SINGLE PLY MEMBRANE: Single Ply Manufacturer / Type: N/A Single Ply Sheet Width: N/A " 1/2 Sheet Width: FINIA No. of Single Ply 1/2 sheets:N/A Single Ply Membrane Fastening / Bonding Material: N/A ❑ FASTENER SPACING FOR BASESHEET ATTACHMENT ❑ SINGLE PLY MEMBRANE ATTACHMENT 1. Field: F " o/c @ Laps & F rows r67 " o/c 2. Perimeter: F61 " o/c @ Laps & El rows � " o/c 3. Corner. " o/c @ Laps &F rows " o/c NUMBER OF FASTENERS PER INSULATION BOARD: 1. Field: N/A 2. Perimeter: N/A 3. Corner: N/A Insulation Fastener Type N/A WOOD NAILER TYPE AND SIZE: : • • •: • N/A • ° ° • 0• • • • • Wood Nailer Fastener Type and Spaciro •... . . • • •: • N/A 0606•6 • • 6 ••66.• EDGE & COPING METAL SIZES: • 6 •6.00 Edge Metal Material: --Galvanized Metal" • 6006 •0... • Edge Size: 1 —3" face 26 ga.— 0 • 00 0. 0 0 6061:6 Hook Strip Size: I --METAL EDGE H(ZOeStRIP WA— ..: • Edge Metal Atttacehment:• . . . . (4"07E 0 .066 i•6.00 GJ ill S Coping Material: I —PARAPET COPING METAL N/A— Coping Size: --EMETAL SIZE N/A— Hook Strip Size: G METAL HOOK STRIP N/A -- Parapet Coping Metal Attachment: N/A section C2d MIAMI -113 E Miami -Dade County Building Department Electronic Application High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, CounterFlashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 16. qq i Parapet: Wall Height d ft. 0000• 0000•• 0000•• 0000 •• •• 0000 •••••• •• • 0000 • 0000• 0000•• Tile Rwf$ystem caurr �� dVe%verrng Excdlewe Every Day"r Miami -Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System Roof System Manufacturer: EAGLE ROOFING PRODUCTS Notice of Acceptance Number (NOA): 11-0321.01 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1. -39.1 p 2• -68.1 p 3: -100.7 Maximum Design Wind Pressures, (From the NOA Specific system): 26.1 psf Fill in the specific roof assembly components. if a component is not required, insert not applicable (n/a) In the text box. Roof Slope: 11/12" Roof Mean Height: _12 ,. -. ft. Method of Tile Attachment: —Adhesive, 2 Small Paddy Polyfoam Polypro-- Alternate Method of Tile Attachment per NOA: N/A Drip Edge Size & Gauge: --3" face 24 ga.- Drip Edge Material Type: - 9alvinized Metal l Deck Type: --5/8" Plywood -- Optional Insulation: N/A Optional Nallable Substrate: N/A Optional Nailable Substrate Attachment: wA Basesheet Type: #30 ASTM _ ..._.._............. 0000....._ _01". 0000 0000.. '. Fastener Type for Basdbheef Attac$ . 1 1/4 RS NAILS ...... .... . .. 0000. Tile Undedayment (C�p• Type:• .;o.. Srggt) . o . ..:o.- 8 TU PLUS •• .. •••• ••` •• .. . • . . 0 . .000.0 • 68 Tile Underlayment Attachment Met :0 . SELF ADHERED 00 0000 • Drip Edge Fastener Type: 11. 1/4 RS NAILS Tile Profile: MALIBU CONCRETE TILE Hook Strip/Cleat gauge or weight: --Na- Section Ce "Delivering Excellence Every Day" Miami -Dade County HVHZ Electronic Roof Permit Form Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based file systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable. P 1: -38.1 x .282 y = 11.Q2 _ Mg; 6.65 = Mrl ; 4.37 , g 26.1 NOA Mf P 2: -68.1 x .282 = 19.20 - Mg: 6.65 = Mr2; 12.55 26.1 NOA Mf P 3: -100.7 x X.282 = 28.40 - Mg: 6.65 < = Mr3; 21.75 5 26.1 NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" For Uplift based tile systems use Method 3. Compare the values for F with the values for Fr. If the F values are greater than or equal to the Fr values, for each area of the roof, then the the attachment method Is acceptable. P1: X 1: = X w: �..... _ - W Description = 0 00 0.. X cos 0. = Fri: 5 NOA F' P2: X 1: = X w: = - W = X cas B: El = Ft2: 5 NOA F' P3:. Table 1 RAS 127, or by an engineer analysis prepared:;;r eAand sealed.by a professioDesign d.. XI: .. ; = Xw:_ ; 0 0.Mean -W: = XCos 0: Roof Height =Fr3: 5 NOAF Where to Obtain Information to complete file calculations Where to Fins! . �..... Description Symbol000.0 Table 1 RAS 127, or by an engineer analysis prepared:;;r eAand sealed.by a professioDesign d.. Pressure P1 or P2 or P3 engineer based on ASCE 7. ; 0 0.Mean . Roof Height H Job Site•'•''"••:• . 0 000 Roof Slope ® Job Site 690666 0096 0000•• Aerodynamic Multiplier Product Approval FOA") ; . . 0406;. Restoring Moment due to Gravity Mg Product Approval #VOA)6 6 6 : • • • • 00 0 0000 0 0 Attachment Resistance Mf Product Approval (NOA) • • • • Required Moment Resistance Mr Calculated Minimum Attachment Resistance F Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) I — length Tile Dimensions Product Approval (NOA) w = width M,®M OWNER'S NOTIFICATION FORM SECTION 1524 HIGH VELOCITY HURRICANE ZONE—REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initials in the designed space indicates that the item has been explained. ® 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that -the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). ® 3. Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should notify the occupants and adjacent units of roofing work to be performed. ® 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetrations of the underside of the decking may not be acceptable. The owner provides the option of maintaining its appearance. ® 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy anilmiTrmance of the new roofing system. Ponding conditions may not be evident until the original roofing sysfem is ri. moved. PoW$' conditions should be corrected. • ® 6. Overflow -scuppers (wall outlets): It is required that rainwater flow off so that Q.,rspf is ngt ovgrloaQ-Il enj a build up of water. Perimeter/edge walls or other roof extensions may block this discharge•if- verfloww seeappersivol . •• • • • ••• outlets) are not provided. It may be necessary to install overflow scuppers in accordance Niifh the reVu*#re•••ments of •• •• ••• •••••• Chapter 15 and 16 herein and the Florida Building Code, Plumbing. .. • • • • • •••••• 7. Ventilation: Most roof structures should have some ability to vent natural airflow through tbeintdrior of the . structural assembly (the building itself). The existing amount of attic ventilation shall not 64eJuced. :••. '0000: Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate fhe attic venting, shall not be required. 17) Owner's/Agent's Signature: ` D` Date:�J // F/I Contractor's Signature: ' Permit Number: Property Address: I 3gA�J U-) I I 1 Vie✓ 12301-197 1 MIAMI-DADE MIAMI-DADE COLINTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) -ww.miamidade.toy/economy Firestone Building Products Company, LLC 250 East 96th Street Indianapolis, IN 46240-3702 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Sectibn that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Firestone Modified Bitumen Roof Systems over Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted h%rein.. RENEWAL of this NOA shall be considered after a renewal application has been filed and ther;l1as loe been no change in the applicable building code negatively affecting the performance of 4is•produtt.,,e:e ..•••. e TERMINATION of this NOA will occur after the expiration date or if there has bee+r>da revision or • change in the materials, use, and/or manufacture of the product or process. Misuse ofJhi5•N.0A as:ft •. endorsement of any product, for sales, advertising or any other purposes shall automatjldfly terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination Ad8€Moval of:*** NOA. •• •• sees *sees* • ADVERTISEMENT: The NOA number preceded by the words Miami -Dade (%unty: Florioa. X11{ followed by the expiration date may be displayed in advertising literature. If any pcJ-tion•Qf the NOA is displayed, then it shall be done in its entirety. •• • •••• • •s•• INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 10-1230.02 and consists of pages 1 through 41. The submitted documentation was reviewed by Jorge L. Acebo. AM 11 Effift NOA No.: 11-0119.09 MIAMI•DADECOUNTY i Expiration Date: 03/08/16 Now Approval Date: 05/02/13 Page 1 of 41 Membrane Type: APP Deck Type 1I: Wood, Non -insulated Deck Description: 1962" or greater plywood or wood plank System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One plv of Firestone MB Base or MB Base M mechanically fastened to the wood deck as described below: Fastening #I: Base sheet shall be lapped 4" and fastened with Firestone All -Purpose fasteners with 3" Round Metal Plates 12" o.c. in the lap and two rows staggered in the center of the sheet 12" o.c. Fastening #2: Base sheet shall be lapped 4" and fastened with approved roofing nails and tin caps 6" o.c. at the lap and two rows staggered in the center of the sheet 6" o.c. Ply Sheet: (Opti Mn JI One or more plies of Firestone MB Base, Ply IV, Ply IV (4) M, Ply VI or Ply VI (6) M ply sheet or other listed base sheet applied in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.; or one ply Firestone APP 160-P torch applied. OR (Optional) One or more plies of Firestone SBS Glass Torch Base or SBS Poly Torch Base torch adhered. Membrane: One APP 180, APP 180-P, APP 180 UltraWhite, APP 180 FR, APP 180 FR UltraWhite torch applied parallel to the base ply, with overlaps staggered 12". Surfacing: (Optional) Any coating, listed below, used as a surfacing, must be listed avithiln a current NOA. Install one of the following: • • • • • • • • • 1. Gravel or slag at 400 Ib. and 300 lb., respectively, set in �floot coat.••o�f pe III or 1V asphalt at 60 Ib./sq.. •••`�• 00•00• • 2. Karnak No. 97, No. 97 AF or No. 169 at an application rjutetf„1'/� ga:Ajq.! • • Maximum Design • •• • 60•06 Pressure: —52.5 psf (See General Limitation #7) 00•••00•• 6•••• 0000• 0900 • • • • 06600• 60000• • • 0 • • • 66 6 0000 •• 00600 • 0 0 0000 NOA No.: 11-0119.09 MUNTY Expiration Date: 03/08/16 Approval Date: 05/02/13 Page 34 of 41 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psE 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 K., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined b3t4q.:. Building Official, a revised fastener spacing, prepared, signed and sealed by a F:orid*a.Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastenereemm"149 shall utilize the withdrawal resistance value taken from Testing Application Sta�8legCoq*s,TAS 105.and calculations in compliance with Roofing Application Standard RAS 117.0000 00 7. Perimeter and corner areas shall comply with the enhanced uplift pressure regait+ements:of &Sse areas. Fastener densities shall be increased for both insulation and base sheps; calculated -in compliance with Roofing Application Standard RAS 117. Calculations prepared, Signed aIT(Ittaled by a Florida registered Professional Engineer, Registered Architect, or Regist&eNA3of ConsuTtant. (When this limitation is specifically referred within this NOA, General Limitation #90w9*14*ot be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination desi&*. shall conform with Roofing Application Standard RAS 11 l and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 11-0119.09 MIAMI-DADECOUNTY Expiration Date: 03/08/16 Approval Date: 05/02/13 Page 41 of 41 9999•• • 9000.. • 9999•• 0000. 0009. 0900.. • •00009 T'GFU.R9516 - Roofing Systems - 0! ) ONLINE CERTIFICATIONS DIRECTORY TGFU.R9516 Roofing Systems Paoe Bottom Roofing Systems See General Information for Rooflno Systems FIRESTONE BUILDING PRODUCTS CO L L C 250 W 96TH ST INDIANAPOLIS, IN 46260 USA Page 1 of 48 R9516 References to Type GI and Type G2 ply and base sheets include "Type IV", "Type VI" (Type GS), "Ply IV (4) M" (Type G1), "Ply VI (6) M" (Type G1), "MB Base Sheet M" (Type G2), "MB Base Sheet" (Type G2) in any of the following Classifications. "Firestone Venting Base Sheet" (Type G3) may be used in lieu of any Type G2 base In any applicable non-combustible Classification. "SBS Poly Base" Sheet can be used In any non-combustible deck system which utilizes a Firestone SBS cap. "ISOGARD", RESISTA and "ISO 300" are acceptable alternates to "ISO 95+" in any applicable Classification. "I.S.O.FIX Adhesive" may be used in any of the following Classifications to adhere Insulation to the roof deck. "I.S.O. Spray'" S" or "Firestone I.S.O. Stick", I.S.O Twin Pack and I.S.O Twin Pack Green may be used in any of the following Classifications to adhere insulation to both non-combustible roof deck substrates and other insulation layers including wood fiberboard and G -P Gypsum Corp. "Dens -Deck@ Roofboard" or "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard." "Tapered ISO 95+CAN" may be substituted for "ISO 95+CAN" in any of the systems listed below. "ISO 95+CAN" may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. 1. Deck: NC ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Class A Incline: 3 Insulation: — "ISO 95+FK", "GL", "GW" or "Rhoflex Isocyanurate FK", "GL", "GW", any thickness, mechapically fastened•6of t4efed witlL • • hot mopping asphalt. • . 6 Ply Sheet: — Two to four layers Type 15, G1 or G2, any combination. • • • • • • • Surfacing: —Gravel. ease** 6 •9999• .... • • • 96 • • 2. Deck: NC Incline: 3 •96. . x.6.69 Insulation: — "ISO 95+Composite", "Rhoflex Isocyanurate Composite" or "ISO 95+Wood Fiberboard Compmltd', mechmicallyfastened 6.6 9 9 or adhered with hot mopping asphalt, 1.5 to 3.5 in. thick. • • •9996• 9999 •699• Insulation (Optional): — Perlite, 1 in. thick. • • • Ply Sheet: — Three to four layers Type 15, G1 or G2, any combination. • • • • 0000 669996 Surfacing: — Gravel, slag or crushed stone. 000000 • • • 3. Deck: NC Incline: 3 : %.0% 0000 • • • • • • Base Sheet: — "MB Base Sheet", mechanically fastened or hot mopped. • • • : 9.9 • : 6 • �; Insulation (Optional): — Any UL Classified (EPS must be covered with 1/2 in. thick min glass fiber, wood fiber or perlitej,OV thickness, mechanically fastened or hot mopped. Ply Sheet: — One or more layers "MB Base Sheet" or Type G1, any combination. Surfacing: — Gravel, crushed stone or crushed slag, In a flood coat of hot roofing asphalt. 4. Deck: C-15/32 Incline: 1 Insulation (Optional): — any UL Classified, any thickness. Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet" or "SBS Base - P" sheet, mechanically fastened or hot mopped, any combination. Membrane: — "SBS Smooth", "SBS Premium" or "SBS" (modified bitumen), hot mopped. Surfacing: — Gravel, crushed stone or crushed slag, in a flood coat of asphalt. S. Deck: NC Incline: 1-1/2 Insulation (Optional): — any UL Classified, any thickness. Ply Sheet: — One or more plies Type G1, G2 or "SBS Base Sheet" or "SBS Base P" sheet, mechanically fastened or hot mopped, any combination. Membrane: — "SBS Smooth", "SBS Premium" or "SBS" (modified bitumen), hot mopped. Surfacing: — Gravel, crushed stone or crushed slag, In a flood coat of asphalt. 6. Deck: NC Incline: 3 http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=... 10/24/2013 TGFU.R9516 - Roofing Systems Page 16 of 48 Barrier Board: — Wood fiberboard, 1 in. min, or one of the following boards at 1/2 in. min: Celotex wood fiberboard, Georgia- Pacific "Sturdi-Top" or Huebert Fiberboard fiberboard. Membrane: — "EPDM", 45 to 60 mil, fully adhered with Uniroyal "Royal M6504" or M6505 adhesive at 75 sq ft/gal. The membrane laps are sealed with Uniroyal "Royal M6365 " adhesive at 1/2 gal/100 sq ft and the lap edges are caulked with Uniroyal "Royal M6389". 77. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Perlite or glass fiber, 15/16 In. thick min, or polyisocyanurate, 2 in. thick min, joints in insulation offset 6 in. with joints in deck. Base Sheet: — Two or more plies "MB Base Sheet" (Type G2) or any Type G2 weighing a min of 23 lbs/sq, mechanically fastened, spot or fully mopped. Ply Sheet (Optional): — "APP 160", "APP 160 P", or "APP 170" (modified bitumen), heat fused. Membrane: — "APP 180 FR" or "RhoFiex FR" (modified bitumen), heat fused. 78. Deck: C-15/32 Incline. 1/2 Insulation (Optional): — Perlite or glass fiber, 15/16 in. thick min, or polyisocyanurate, 2 in. thick min, joints in Insulation offset 6 in. wi i is in d < Base Sheet: T o or more plies "MB Base Sheet" Type G2) or any Type G2 weighing a min of 23 lbs/sq, mechanically fastened, spot or u y r: pp . Sheet O tional): — "APP 160", "APP 160 P" " P 170" (modified bitumen), heat fused. m ra e: — mo i bi en , heat fuse . 79. Deck: NC Incline: 1/4 Insulation: — Atlas Roofing "ACFoam II", Rmax "Multi -Max FA", Apache "White Line" or "Pyrox", any thickness. Membrane: — "LS -FR" (EPDM), 45 or 60 mil. 80. Deck: NC Incline: 3/4 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — Wood fiberboard, 1/2 in. thick min. Membrane: — "LS -FR" (EPDM), 45 or 60 mil. 81. Deck: NC Incline: 1/2 Insulation (Optional): — "ISO 95+ GL", wood fiberboard or periite, any thickness. Membrane: — "LS -FR" (EPDM), 45 or 60 mil. 82. Deck: C-15/32 Incline: Unlimited Insulation: (optional) — Any UL Classified, any thickness • • Barrier Board: — Min 1/4 In thick, GP Gypsum "DensDeck O Roofboard" or "DensDeck Prime6 Rogfboarg" or "DeldbM 191-Ime 2TM Roofboard" or "DensDeck DuraGuard@ Roofboard" with all joints staggered a min of 6 in. fromthe plywood joints. Membrane: — LS -FR (EPDM) adhered with BA 2004(T), Single -Ply LVOC Bonding Adhesive, Single -ply LVOC Bon(Irg9cftsive 1168 or Water Base Bonding Adhesive -P. 000600 • • 83. Deck: NC Incline: 1 0 0 0 0 0 6 0 Insulation (Optional): — Glass fiber or periite, 1 in. max, mechanically fastened. Membrane: — One layer "SBS Metal Flash -AL" (modified bitumen), heat fused or hot mopped. 84. Deck: NC Incline: Unlimited 0000 • • 0000 0000•• • •• •• 06••06 • Insulation (Optional): — Polyisocyanurate, polyisocyanurate/perlite composite, phenolic, phenoac/pe*rlit3 compg6ite, glass fiber, wood fiber or perlite, any combination, any thickness and/or EPS covered with min 1 in. pert te, wol d fiber 01,419/4641n. glass fiber. Base Sheet: — Type G2, one or more plies. • • : . • • • Membrane: — "SBS Metal Flash -AL" (modified bitumen), heat fused. • 0000 85. Deck: C-15/32 Incline: Unlimited Insulation: — Polyisocyanurate, 1-1/2 in. thick min, joints in insulation offset 6 in. with joints in deck. Base Sheet: — One or more plies Type G2, mechanically fastened, spot or fully mopped. Membrane: — "SBS Metal Flash -AL" (modified bitumen), heat fused. 86. Deck: C-15/32 Incline: Unlimited Insulation: — Perlite or glass fiber, 1 in. thick min, joints in insulation offset 6 In. with joints in deck. Base Sheet: — One or more plies Type G2, mechanically fastened, spot or fully mopped. Base/Ply Sheet: — One or more plies Type G2, hot mopped in place. Membrane: — "SBS Metal Flash -AL" (modified bitumen), heat fused. 87. Deck: NC Incline: 1/2 Insulation (Optional): — Any UL Classified, any thickness. Insulation: — Glass fiber, wood fiber or periite, 1/2 in. min thickness. Membrane: — "UltraPly TPO". 88. Deck: C-15/32 Incline: 2-1/2 0000•• • • • 0000•• 0000•• 0000• 0000• 0000•• • • • 0000•• • • •00••• • http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.htmlMame=... 10/24/2013 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11905 SW 26 Street, Room 208 DOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T(796)315-2590 F{786)315-2599 NOTICE OF ACCEPTANCE (NOM wrrw•miamid�av/buildin Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AEU). This NOA shall not be valid alter the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,'modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements ofthe applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Malibu Concrete Tile .000.0 000 0 000000 LABELING: Each unit shad bear a permanent label with the manufacturces name or !d city, $pd ' . following statement: "Miami -Dade County Product Control Approved", unless otherv"";;( ted herein. :0000: 00 ...... RENEWAL of this NOA shall be considered after a renewal application has been filly a0a0 there.. been no..... change in the applicable building code negatively affecting the performance of this pmd� d.-. ; • • • • • 0 • • • 00 00 0000 0000.. ENATION of this NOA will occur after the expiration date or if there has beenn a Wision. or change in they : • materials, use, and/or manufacture of the product or process. Misuse of this NOA as ey en¢orsemirdbelttny • product, for sates, advertising or any other purposes shall automatically terminate thi,?WA: Failure to romplJ • • • • with any section of this NOA shall be cause for termination and removal of NOA. 00:0 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Oficial. This renews NOA #06-0526.09 and consists of pages l through 7. The submitted documentation was reviewed by Alex Tigera. I� NOA No.: 11-0321.01 CMADECOrr Expiration. Date: 10/05/16 • S � ►NHRSWAN=Approval Date: 05112/11 Page 1 of 7 ROOFING ASSEMBLY APPROVAL VatMe Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a system using Eagle Roofing Products Malibu Concrete Roof Tile, as manufactured by Eagle Roofing Products LLC in Sumterville, FL. and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PjKoDuCT DESCRUMON-. Manufacturted by Test Product A nln scant Dime nsia spg, kas Description Malibu Concrete Tile 1=17" TAS 112 Low profile, interlocking, high pressure W =12 Y2" extruded concrete roof file equipped with '12" thick duce nail hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for w = varies use at hips, rakes, -ridges and valley varying thickness -terminations. Manpfactpred fcy-t6�rtile profile. 6..0 000.0. 0.000. 0000 0000 0000.. 0000 0000.. 0000.. 0000 0000 0000.. 0000 0000.. 0000.. 0000. 0000. 0000.. 0000.. 0000.. NOA \io.:11-0321.01 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 2 of 7 NOA Ne.:11-0321.01 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 3 of 7 2.1 EVIDENCE SUBMITTED: Test Agency Test IdeatfCer Test Narna&enort Die PRI Construction Materials PR[06178 TAS 112 08/23106 Technologies Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix R TAS 108 (Nairn) Redland Technologies P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs. smooth shank nails The Center for Applied 94-060B Static Uplift Testing March,1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101(Mortar Set) Redland Technologies P0631 -0I Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Professional Service 224-47099 Physical Properties Sept. 1994 Industries, Inc. TAS 112 The Center for Applied 25-7094-1 Static Uplift Testing Oct. 1994 Engineering, Inc. TAS 102 (4" Headlap, Nails, Direct Deck, New :...:. Construction) ❑ • • : ...... • The Center for Applied 25-7094-7 • . Static Uplift Testing • • : • • 'Oct 1994 ... • • Engineering, Inc. TAS 102 **sees ' 00080 (4" Headlap, Nails, Battep4l. • a • : •' • The Center for Applied 25-7094-4 Static Uplift Testing • : • •: .. ..... Qert- •1994 • • : • • • Engineering, Inc. TAS 102 " " "" ""•' (4" Headlap, Nails, Direct%%H; •. Recover/Reroof) • • • • • • ....:. The Center for Applied Project No. 307025 Wind Driven Rain • " Qat' K 994 ' • • • • Engineering, Inc. Test #MDC -76 TAS 100 0000 The Center for Applied 25-7183-1 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (2 Quik -Drive Screws, Direct Deck) The Center for Applied 25-7183-2 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (2 Quik -Drive Screws, Battens) NOA Ne.:11-0321.01 Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 3 of 7 The Center for Applied 25-7214-2 Static Uplift Testing March, 1995 Engineering, Inc. 25-7214-6 TAS 102 106 may required, refer to applicable building code. 3.3 (1 Quik -Drive Screw, Direct Deck) ...... quarterly test in accordance with TAS 112, appendix `A'. Such testing shall & submitted to (I Quik -Drive Screw, Battens) Celotex Corporation 528454-2-1 Static Uplift Testing Sep. 1998 Testing Services 520109-2 TAS 101 Dec. 1998 Walker Engineering, Inc. Evaluation Two Patty Adhesive Set System April 1999 unless stated otherwise by the underlayment material manufacturers publikbe8 literauh. Calculations 3.6 This acceptance is for wood deck applications. Minimum deck requirep;Ihall be iA Walker Engineering, Inc. Evaluation 25-7183 March 1995 Calculations Walker Engineering, Iac. Evaluation 25-7094 February Calculations 1996 Walker Engineering, Inc. Evaluation 25-7496 April 1996 Calculations Walker Engineering, Inc. Evaluation 25-7584 December Calculations 25-7804b-8 1996 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Calculations Aerodynamic Multiplier Sep. 2006 Walker Engineering, Inc. Calculations Restoring Moment Due to Gravity Sep. 2006 3. L[1v1rrA ms: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to ldit?m ...... quarterly test in accordance with TAS 112, appendix `A'. Such testing shall & submitted to the Building Code Compliance Office for review. . • • • • • • • • • • • 3.4 Minimum underlayment shall be in compliance with the applicable RodflfiAlApplicatiohs ;....; Standards listed section 4.1 herein. • • • • • • • 3.5 30/90 hot mopped underlayment applications may be installed P�'Pend19�at&•�1jo the roQliloPe• ..:..' unless stated otherwise by the underlayment material manufacturers publikbe8 literauh. ...... 3.6 This acceptance is for wood deck applications. Minimum deck requirep;Ihall be iA • compliance with applicable building code. ' ' :...:. """ *000 NQA No.:11-0321.01 FtlAM4aA burr Expiration Date: 10/05/16 • • • ® Approval Date: 05/12/11 Page 4 of 7 4. INSTALLATION 4.1 Eagle Roofing Products LLC Malibu Concrete Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (l x w) Tile Profile Weight W (ibf) 1 Length-1(ft) 1 Width -w (ft) 1 Malibu Tib 9.5 1.417 1.04 Table 2: Aerodynamic Multipliers - ft Tile Profile X (ft) Batten Application % (ft) Direct De lication Malibu Tile 0.305 0.282 Table 3: Restorin Moments due to Gravi - M ft -lb Tile Profile 3":12" 4":12" 6":12" 615:12`` 7":12" or oreater Malibu Tile Battens Direct Battens Direct Deck Battens Direct. Deck. Battens Direct Deck Battens Direct Deck 6.30 6.65JI 8.21 1 6.54 6.08 6.41 5.93 1 6.25 5.77 1 6.08 Table 4: Attachment Resistance Expressed as a Moment - Mi (ft-ibf) for NalWn Systems asses* Tile Profile Fastener Type Direct Deck (min 15132" plywood) Direct Ddak' : (min. 191329... plywood) • • • • poop . . Patton :see" • .. . o Malibu Tile 2-10d Ring Shank Nails 27.8 37.4 .8 1-10d Smooth or Screw Shank Nail 8.8 11.8 ..'..' ....1 . 2-10d Smooth or Screw Shank Nails 16.4 21.9: : 7.1 . 00000 1 #8 Screw 25.8 25.8 '..' :2&P• 2 #8 Screw 47.1 47.1 00%9.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nall Field Clip) 1-10d Smooth or Screw 18.0 19.0 22.1 Shank Nail Eave Clip) 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nabs Eave CII 2-10d Ring Shank Nails 43.0 67.5 50.9 1 Installation with a 4" tile headlep and fasteners are located a min. of 2W from head of tile. NOA No.:11-0321.01 Expiration Date: 10/05/16 Approval Date: 05f12/11 Page 5 of 7 poop. poop. poop. poop pose 000.0 pope. P Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum ch ant e Malibu Tile Adhesive 26.1 2 See manufactures component approval for installation re ulrements. 3 Flexible Products Company TiieBond Average weight per patty 11.4 grams. Polyfoarn Product, Inc. Average weight per pgtty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-Ibf) for Single Patty Adhesive Set Systems Tile Profile Tile The Application Minimum Attachment Resistance Malibu The Resistance Polyfoarn Po! ProTm 86.61 Pol foam PolyProTm 45.5 4 Large paddyplacement of Marams of PolYProTW. 4 Medlum paddy placement of 24grarne of PolyProm. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-ibf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Malibu Tile Mortar Set 20.60 9999.. 9999.. 5. LAB1yuNG : •..• : .' All tiles shall hear the imprint or identifiable marking of the manufact Mtrffame or logo (See • • •' • Detail Below} or following statement: "Miami -Dade County Product Cor&Appro yed% • • • • .... . .. ..... . ...... 0..9 09..0 .. .. 99.. 9600.. 9 9999.. • 9 • • • )k -EAGL' 0999.. 0 0 0 . • . • l � • . • 9999.. .. . 9999 . . 9909 . fFlf FLORIDA MALIBU CONCRETE ROOF TILE ]LABEL,, SUMTERVILLE. PLANT (LOCATED ON UNDERSIDE OF TILE) NOA No.:l 1-0321.01 A 01AA M IN. NEYOUN� Y Expiration Date: 10/05/16 Approval Date: 05/12/11 Page 6 of 7 6. BUILDING PERMIT REQummi NTs: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building ficial or Applicable building code in order to properIy evaluate the installation of this system. PROFILE DRAWING MALIBU CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.:11-0321.01 Expiration Date: 14/05116 • mmp, NOW Approval Date: 05112!11 Page 7 of 7 MtAMI�D MIAMI DARE COUNTY � PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wv misuddade go`teioneow Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments • LABELING: Each unit shall bear a permanent label with the manufacturer's name or loip,eitt, stat` and,following , • statement: "Miami Dade County Product Control Approved", unless otherwise noted heroine : • • :00000 0.9 0:0 000000 0 • • 0.000• RENEWAL of this NOA shall be considered after a renewal application has been filed W there haClted po chQe • in the applicable building code negatively affecting the performance of this product. • • • • • . • so:* •:• ... . . •9 00 0000 ...... TERMINATION of this NOA will occur after the expiration date or if there has been aircy on or change in the 00 materials, use, and/or manufacture of the product or process. Misuse of this NOA as an Adors&nent of any products • r • for sales, advertising or any other purposes shall automatically terminate this NOA. Failite tp%omplp;AM any sec ttio n of this NOA shall be cause for termination and removal of NOA. • • • : • • • • 0090 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. ,.: APPROVED J NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Ca o : Roofing Sub -Category Underlayment Material: SBS, APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'3 3/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof the underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'3 3/g' ASTM D 1970 fiber/polyester reinforced waterproofing 42 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-4713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 6518" x 3'3 3/s' waterproofing membrane, glass fiber reinforced Matwfactuuring Location 60 mils thick with polyolefinic film on the upper surface for use as an underlayment for metal roofing, roof #Z tile, slate tiles and shingle underlayment. Polystick IR Xe Roll: TAS 103 and A fine granular/sand top surface self -adhering, underlayment 65' x 3'3-'/s" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32'10" x 3'3 3/$" ASTM D 1970 polymer modified, fiberglass or polyester Mann facturing Location 100 mils thick reinforced, bituminous sheet magi fpr use as an underlayment in slopes foof a'semblies. • •' 0 : • #1 & #2 Designed as a a roofal,�•4}derla�•sanex;.• � • • • • • Polystick TU Plus Roll: TAS 103 and 000••0 0 • • A rubberized asphalt Whadheriq& glass- ; • • • • ; underlayment 65' x 3'3 3/g" ASTM D 1970 fiber/polyester reinfopoed waterpto8fi&A ..... (Surface Printing) 80 mils thick membrane. Designed-4wiaetal roqjM and. reJ- • • Manufacturing Location as0000 •"•.• file underlayment. as :**:a: . #1 &#2 0 0.00•• Polystick TU P Roll: TAS 103 and A rubberized asphalt Watefeproofingammbrar , • a • underlayment 32'10" x 3'V%" ASTM D 1970 glass-fiber/polyester reinforced, MM a granular Manufacturing Location 130 mals thick surface designed for use as a tile roof underlayment. #2 Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'3 3/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof the underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 61' x 3'3 3/g' ASTM D 1970 fiber/polyester reinforced waterproofing 42 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-4713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PR®DuCT5 DESCRIPTIom Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self -adhering, polyester Manufacturing Location 65'8" x 3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed #2 60 rails thick as a a roof file underlayment. MANUFACTURING PLANTS: l.Hazelton, PA 2. Winter Haven, FL EVIDENCE SUBMITTED: Test Aaency Test Identifier Test Name/Renort Date Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity M P5110.08.07 'FAS 103 08/29/07 P10870.09.08 -RI TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09401/11 P37300.10.11 TAS 110/ASTMD4798&:DV0 •IW9/11 ....�. P40390. 08.12-1 TAS 103 & TAS 110" ;•9$tQ6/12 • P40390.08.12-2 ASTM D 1623 08/07/12 • • • • • • P40390.10.12 ASTM D 1970 16/03/12 :....: PRI Asphalt Technologies PRI01111 .... ASTM D 4977 ..... ; • ..... OJZQ8/02 PUSA-045-02-01 ASTM D 4977 ...... DV31102 ..;... PUSA-018-02-01 ASTM D 2523 • • • • • •:WI14/03 ...... PUSA-035-02-01 TAS 103 :00:0: 09/29/06 • , PUSA-033-02-01 ASTM D 1970 ' 0; . PJ112/06 • • • • • • PUSA-055-02-02 TAS 103 •0 • * 12/10/07 :....: PUSA-083-02-01 TAS 103 0 00%730/08 PUSA-089-02-01 TAS 103/ASTM D4798 & G155 07/06/09 Momentum Technologies, Inc. JX2OH7A TAS 103/ASTM D4798 & G155 04/01/08 RX14E8A TAS 103/ASTM D4798 & G155 11/09/09 DX23D8B TAS 103/ASTM D4798 & G155 02/18/10 DX23138A TAS 103/ASTM D4798 & G155 02/18/10 NOA No.: 12-0713.02 M�AMFatun COu+v7Y Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FSC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Poiystick membranes self -adhered. Surfacing: None 1. All nails in the deck shall be careMy checked for protruding heads. Re fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3-'/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance.• 0000.. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment.: Tjx7tashing tape shall 6e' pressed in place and formed around the protrusion to ensure a tight fit. A second Wgg pf Polystiekshall b i .:: applied over the underlayment. • • • • • • 0 0000 .. 0000.. 0000 . .. 0000. 0000.. 0000 00000 00 00 0000 060000 0000.. . . . . . . ...... 0000.. . . 000000 .. ....0000 NOA No.: 12-0713.02 MUMIFUADECOU R Expiration Date: 04/13/16 Approval Date: 02/14/13 Page 4 of 8 GF ERAL UwTATIONSe 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof the systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Ex osure Limitations da s Polystick MTS MTS Ut-Xe TU I TU Plus TU P Tile Pro I Dual Pro I TU Max Polystick TM V1 Winter Haven, FL. I80 I80 I80 180 I80 180 I80 90 Hazelton PA. N/A 30 30 1 180 N/A N/A NO N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof file manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof file applications. Polystick IR -Xe, and Dual Pro ft "ted to mechanically fastened roof tile applications. Polystick MTS is limited to mechanwi* ppS%f istened with batteM • • ; • roof tile applications. Polystick TU P may be used in both adhesive set and mechq4ip& fastive&6of tile • • G O • applications with the exception of mortar set tile applications. 0 Do 0 0 0 0000.. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile, ItUftiblies:Wbe as • 0. follows: (See Table Below) 000 • 0000.. 0000 00000 Tile Profile Polystick MTS Polystick IR -Xe Polystick TM V1 Pdl"tick To • • Plus, TU Pyi-o : Max Pro •••••• ... Flat Tile Prohibited without 5:12 No limitatibli No limritatioir battens .000 Profiled Tile Prohibited without Prohibited No limitation No limitation battens The above slope limitations can be exceeded only by using battens and counter battens in accordance with the Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens are required for both loading and installation of tiles at all times. NOA No.: 12-0713.02 MUU71•QADE .OUNTYM Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should betaken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of file directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. a O d7 CV r m �SY;, ,�tthM� c r°�' ]tn, Vis• yk F� ^ . s <` yE W i Mof Deck pteWed with POLYST(CKT- U Plus It. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. IfPolystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results.6 9 9 6.0 • • e 9999•• •• • • •• •0000• • LABELING: •••�•• • •0000• •00.0• • • 1. All membranes or packaging shall bear the imprint or identifiable marking of the rMgfacturefp name or liiow'- city and state of manufacturing facility and the following statement: "Miami -EW& C•ounty:Pi'gaifct Co" • « Seal assbownbelow. •••• 96:006 9999•• /�pprOVed Or the Mia�1T Dade County Product CODtf'o� S • • • •• •• •••• •••••• MID,MEDADE COUNTY • • • • • • • • 6 • ° • • • • • • • • •0006• 9999•• BUILDING PERMIT REQUIREMENTS: 00006:0 6069 Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this materials. MMANOA No.: I2-0713.02 �DOUNExpiration Date: 09/13/16 'ggxs° Approval Date: 02/14/13 Page 6 of 8 POLYGLASS GENERAL AFFLICATION GuiDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum I" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter battens, as required by the file manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4 /12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, extosed AUCYC,.or exposed roof to wall details. • 9. Repair of Polystick membranes is to be accomplished by applying Polyglass PoWttff Pretgi iModified•.: • Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, PolyglaU M500 MB Ftashing ; .... Cement to the area in need of repair, followed by a patch of the Polystick materiafof Eike kina'shotdd be At and hand rolled in place over the area needing such repair. Patching membrane sb4*Jb.*era minim of 6 inches in either direction. The repair should be installed in such away so that wat&.Vffl run&40el toot ..... over the top of all laps of the patch. • • • • • • • 10. All self -adhered membranes must be rolled to ensure full contact with approved;ubstfates. ]!@*S:ws requires a minimum of 40 lbs for a weighted roller for the rolling of the field meftJVW. Hand j7pVVrs ark • • • • acceptable for rolling of patches or small areas of the roof. Brooming may be used where slopeprohibits rolling. 11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick membranes commences. An approved substrate technical bulletin can be furnished upon request. It is recommended to refer to applicable building codes prior to installation to verify acceptable substrates. 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1(800) 894-4563. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NBCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE NOA No.: 12-0713.02 MIAMFDADECotJNTY Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 8 ...... . ...... .... . .. ..... ...... .... ..... .. .. .... ease.. .•..•. . . a . . ..... aaee.• 0.00 009 V666: • 0000 NOA No.: 12-0713.02 MIAMFDADECotJNTY Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 8 of 8 MIAAH DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DMSION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www, ad ami dade.eovleeo°arm' 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. R.ER. reserves the right to revoke this acceptance, if it is determined by Miami Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. (DESCRIPTION: 3M11M 2 -Component Foam Roof Tile Adhesive AH -160 • • ; :04069 • LABELING: Each unit shall bear a permanent label with the manufacturer's name or rded,•city, state and follc�►�yiva statement: "Miami Dade County Product Control Approved", unless otherwise noted hereins • • • : • ... . .. ..... • RENEWAL of this NOA shall he considered after a renewal application has been fileWd1here h •en no efian •e in the applicable building code negatively affecting the performance of this product. • • . e • . . . . ...... TERMINATION of this NOA will occur after the expiration date or if there has beQi a•rgvisioi; or change in the. materials, use, and/or manufacture of the product or process. Misuse of this NOA as an enMrsetnent of pyproduet, for • sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply v3iM lany section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using 2 -Component Foam Roof Tile Adhesive AH -160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Descriation Snecifications 3MTM 2 -Component N/A TAS 101 Two component polyurethane foam adhesive Foam Roof Tile Adhesive AR -160 Foam Dispenser N/A Dispensing Equipment RTY1000 ProPack® 30 & 100 N/A Dispensing Equipment •6•••• e • • 0606•• PRODUCTS MANUFACTURED BY OTHERS: 0000.. • Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a curren& NQ& which lisp attachment" resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tileA44esive.. :06600 00006 .. . .. • 0000. MANUFACTURING LOCATION: 0"""" 0000 .�.. 0000•. 1. Tomball, TX. • •. • • • .' •6.66• • • • • 0 PHYSICAL PROPERTIES:• • • • • • 6 • • .. 0000 ProveProverty Test Results s o % Density ASTM D 1622 1.6 lbs./ft.3 Compressive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127 0.08 Lbs./Ft' Moisture Vapor Transmission ASTM E 96 3.1 Perm / Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 14-0805.01 MIAM4DADECCIU 3 Expiration Date: 05/10/17 ' ' ' ' • Approval Date: 09/04/14 .Page 2 of 11 EVIDENCE SUBMITTED: Test As!encv Test Identif er Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 0.00•• 0000.. 520109-1 TAS 101 ' • •' . 12/28/98 .' 520109-2 •'•••• 0000.. • •••••• 520109-3 •••••• 0 ,0 0000.. 520109-6 • • • • • e s • • 520109-7 0.00 •• 00.0• 520191-1 TAS 101 • • • • df/0�/99 • " •' 520109-2-1 ...... 0000 0000.. 0000.. • • • • •0,000• 0000•• LIMITATIONS: . • 0000.. .. 0000 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fiWo ting. 2. 3.Ne 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of Mm 2 -Component Foam Roof Tile Adhesive AH - 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. NOA No.:14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 3 of 11 INSTALLATION'. 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTm 2 -Component Foam Roof Tile Adhesive AH - 160. 2. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof file assembly's adhesive attachment with the use of 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTm 2 -Component Foam Roof Tile Adhesive AH - 160 Operating lnsttuction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. :060:6 9. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty 6vteight shill b %in • • • • accordance with the Placement Details' herein. Each generic tile profile requires the.WjUc plg mens noted • • • : • herein. 096:96 9 0 • NOA No.: 144=5.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 4 of 11 .0000. 0006 .. • .... . .. ..... . • ...... .... ..... •0••0•• 00 . . • •...... ...... • • • •0000• •• • 0000 • •0000 NOA No.: 144=5.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Eave Course - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, Low, High Profiles #1 1723 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer`s name or logo and following statement "Miami -Dade County Product Control Approved':aci'he Miami- . . •6.6•• Dade County Product Control Seal as shown below. • MIAMFDADE COUMi *00:00 • ... ••• s 0000•• • • • 0000•• 0000 •• • :.0006• • • • • BUILDING PERMIT REQUIREMENTS: .0000 0 0 0..... ...••. ..... As required by the Building Official or applicable building code in order to properly evaluate tfit:•instai ofthis• 0 0 0:0 ••666• • system. • .0000. • • • 0000 •• 0060• •• • • 0*00 NOA No.: 14-0805.01 MIAMFDADECOUWTYli Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 14x1! R0�t9ttgh � cavaa� twhemewga+lt•d�a --Paddy (80nosthrAwl��!•y `fie; � .. ;�,� 2 Ht.wiBf• `a { �ti•.�, ,�J�,.. µ`Vi.;:"•` .r"�' %iVQ C�bSYfO haat c C•cnt• w 4' ~.— . Fin .s= Nag atrswghPWIlt9WPKW-,,. t=nd t8•n•athrt{.1 tWhan Fe ed# << urowuymw I ^yy'�°:>pk4 � '•.y ' fir 4, 40ia.ai y 41 Fascia Umdoswe }, Weephoie APPROVED Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1.. Starting at the eave course, apply a minimum 2" (50.8 mm) x W'(254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same ma4ner. Insure mately17• • (109.7 cm) — 23 (148'44n). square inch adhesive. • contact with the undemida-ofthe dl'e.. ....:. •00.00 • 0000 • •• 0000• 0000•• 0000 0000• •• •• •••• •••••• • 0000•• • • High Profile / Single PA4 Tite ; • • . • ; 0000•• • • • • • 1. Starting at the eave comme, apply a minimum I (50.8 mm) x 10" (254 mm) x 1" (25.%emm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 awyuyA �1�. Wc uea,.n./ w.ddp ► 5,..►h ) Uftd&tUY"WM 1.4 ( '` i. saeea�conei4nat �,,�' V kti �• `�4 ��f�,�1 f, �• r ��vY •,. F Jar'. i/.F:atua fly r 2 0000.' •,� °.,.ss J r. Eavecieawo..__ (who" re¢&WI E.W. CIOU" Foods Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 tam) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the file closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second coarse, apply a minimum 2" (50 -8mm) x T'(177.8 mm) x 1" (25.4 nun) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the file being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm) -12 (77.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a tttq MJW 2" (50.8 mm) x 10" (254 mm) x l:' (20..4 mm)•foam paddy • • • ; • onto the underlayment pogiEionl d as AxvAunder the %� • pan portion of the file closes; to the overlock of the 0000.. . file being set. Insure app; q ately 17•(102.7 cm2 — 23 (148.4 cm) square inC$xUltsive QoffWtwith the, • • underside of the tile. 0 0 0 0 0 0 :060 ..:..' 00 •• 0000 0see00 2. At the second course, ap§l Pgt:inimum r (50.8mm)•, x T' (177.8 tum) x 1" (23.4 mid) foat$,patli* onto tife •' underlayment positioned;as Awn under the pan ...... portion of the tile closest to the over1q jj gtthe tile • being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 14-0905.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 7of11 ADHESIVE PLACEMENT DETAII. # 2 (CONTINUED) 1rt.H shaeugh mastic c� � asday ta6ar+slk TiH►S 1w�4n ►4ao+ir601 Battens 0040" W r fisreGowsefascia 104n. Orlp edgc�osVte High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x I W' (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm) -19 (122.6 cm) square inch adhesive contact with the underside of the tile. . .000.0 NOA No.: 14.0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 8 of 11 0946.. .. . . . 6 0000.. 9 0000.. . 0000.. 966646 6 . 9 :**a*: 000.. 6964 .. 0 9 0000 0000.. .664 6444. 06 96 04.9 9600.4 6469..9 as . . 6 0 0000.. .....0 0 . 66009. .. 00000000 NOA No.: 14.0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 8 of 11 ADHESIVE PLACEMENT DETAm # 3 FkWLWProMGTS9 MedImPrOMM 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the the for low or High profile file closest to the overlock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm) of adhesive contact with the underside of the the 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course file to be installed. Insure approximately 8-9 int (51.6-58.1 cm2) of adhesive contact with the underside of the tile. NOA No.: 14.0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 """ (Instructions continued onizextpage) • 9..999 .. . . . • • 9.99.9 • 9999 • •• 9999• 9999•• 9999 9999• •• •• 9999 s••••• • 9999•• 0 • • • • 9 99990• 9999•• • • • •9060• 0*60 NOA No.: 14.0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 A 0 ADHESIVE PLAcmENT DETAIL # 3 (CONTrqum) 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm)-11(71cm) square inch adhesive contact with the underside of the file at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch • 0000•• 0000•• • 0000•• • 0000•• • 0000•• �. • • PR 0000•• 0000 •• • • • 0000 • •• adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • • • 0000•• 0000•• • 0000•• • 0000•• • 0000•• • • • 0000•• 0000 •• • • • 0000 • •• 0000• 0000•• 0000 0000• sees** •••• •••••• • 0000•• • • • • • • 0000•• 000.06 • • • • • •• • 0000 • • NOA No.: 14-090.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 10 of 11 e ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL t) Ptm erwtrshadhestveto aditve SSto 70sq.im Steep in contact with the pantNe (when 2) sum covers upside down. Place adhesive In to t In. from outside edge of covertile. Then install the tile. Ensure 20 to 25 sq. in. contact area; Undartayment Eave closure (mom Fascia Aemave top portion of the eave course cover tile. Abut to second course of pan tiles. Easure eave end of pan and corer tiles are flush at eave line. Two Piece Barrel - High Profile Tile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 nun) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. .6004. 606090 4. Turn cover file ovef mer €oam is applied and Place onto pan tile tt�a►>lrt+sev Insure a tm unum ®f.:. 20 (129 cm) - 25 (i6 i lleom) square inch 6.0 0: contact area on eac$ Side pf the j t yer dile to the pan tile. Continue in4s%W mand&r. Ttim awv:4'. any cured exposed 10`AW4Jhesive.ntmg of 4" • 4• 6666.• longitudinal edges 4 •• eojover Ate's6are • considered optional; 4 4 04••6• 5. When additional naikxg ie requiredpTe' (50.9 • • • • mm) x 4" (101.6 mm) nailers 6rod;�tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE NOA No.: 14-080 s.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 11 of 11 „:AF4zN"N KEN LAVSON, SECRETARY STATE OF FLORIDA. DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD The. ROOFING CONTRACTOR IS CERTIFIED tinder #* provWons of Chapter 489 FS. E - AUG 81, 2016 "il I MARTINEZ. JAVIER RO knAW ROOFING SYS 'Z BUCCANEER AVENUE„ NORTH BAY VILLAGE Ft 33144 rte,;