RF-13-1739«a�
j
Miami Shores Village
Building Department
90050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
BUILDING
PERMIT APPLICATION
Permit Type: BUILDING
JOB ADDRESS:
FBC 20
Permit No.
Master Permit No. -4 37
Ci00FING
V
City: Miami Shores County: Miami Dade Zip:
Folio/Parcelk 2 3 d f? -13 b®/ o
Is the Building Historically Designated: Yes NO Flood Zone:
OWNER: Name (Fee Simple Titleholder): / Haoms ulzvoik-t '4 e,
City: felChi KWe5 State: ;PC Zip:
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: xv
Address: r3 i 97. r
City:
M, �
State Certification or Registration #: 66 C o /-1' 3 6 i�' Certificate of Competency
Contact Phone#--��� (e f 2 Email Address: dO�Ll /Z v
DESIGNER: Architect/Engineer.
will
Valve of Work for this Permit: $_ ®& Square/Linear Footage of Work: �--I
Type of Work: OAddition OAlteration ONew
Description of Work:
Submittal Fee
Scanning Fee $
Color thru We:
A
Permit Fee $ CCF $ CO/CC $
Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $
1313emolition
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City
State
I.
zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMENCEMENT."
ENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the ,first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged. Z/
I I! W141 VIA W01 _ '
Owner or Agent
The foreffoing instrument was acknowledged bef re me phis 80
day of , by
who ' own to me or who has produced
As identification and who did take an oath.
Contractor
i
fing i strument was acknowledged before me of 20 o Imoby
is personally own to me or who has produced
as identification and who did take an oath.
NOTARY PUBLIC: NOTARY PUBLIC:
APPROVED BY Plans Examiner Zoning
Structural Review Clerk
(Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009XRevised 3/15/09)
;lOOF ASSEMBLIES AND ROOFTOP STRUCTURES
rLF ) 7 ) 7 '?
Florida Building Code Edition 2010
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section A (General Information
Master Permit No. Process No.
Contractor's Name ®% A�ClVdll- / ;EOV Grp/ 9
Job Address
ROOF CATEGORY
Low Slope ❑ Mechanically Fastened Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles
Prescriptive BUR -RAS 150
ROOF TYPE
❑ New Roof
15.34
e 05
f3<,
i` L pe jof
N
Recovering Repair
SOF SYSTEM
a
le
❑ Maintenance
V 7
RMATION
Ste Sloped Roof Area (SF) Total (SF)
'Cj
ft (Roof Plan)
a OAs;
ROOF
A3EMBLIN AND
ROOFTOP
O€tOD UN UM @!1
-/7 3�1
Florida Building Code Edition 2010
High -Velocity Hurricane Zone Uniform Permit Application Form.
Section C (Low Slope Application)
Fill in specific roof assembly components
and Identify manufacturer
(if a component is not used, identify as "NA")
System Manufacturer: j�5,4,C7/ /
Product Approval No.: G'=
Design Wind Pressures, From RAS 128 or Calculations:
P1: Z- K P2: -71 7 P3: /® V
Max. Design Pressure, F—m the specific Pro�Vct
Approval system:
Deck:
Type: It "W-0 9A/ cm 7wee k
�r
Gauge/Thickness:
Slope: T
Anchor/Base Sheet & No. of Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer: J
Base Insulation Size and Thickness:.
Base Insulation Fastener/Benrlina Material:
Top Insulation Layer: /,1r9
Surfacing: N
Fastener Spacing for Anchor/Base Sheet Attachment:
Field: " oc @ Lap, # Rows @ It
oc
Perimeter: " oc @ Lap, # Rows _ @ " oc
Corner: " oc @ Lap, # Rows @ " oc
Number of Fasteners/per Insulation Board:
// "
Field Perimeter Corner
Illustrate Components Noted and Details as
Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counter- Flashing, Coping, Etc.
:
Indicate: Mean Roof Height, Parapet Height, Height of
Base Flashing, Component Material, Material Thickness,
Fastener Type, Fastener Spacing or Submit Manufactur-
ers Details that Comply with RAS 111 and Chapter 16
,E7��.ri todr+r'r'�,E
fr-nsyrr.'�
�x�l'F- �r.9SHrriG •
Top Insulation Size and Thickness:jrili/✓/O�r•�f�f_//��
Top Insulation Fastener/Bonding Material: .�� /o sr�Gu rGrai
" 1T.evrrvo�c
Base Sheet(s) & No. of Ply(s): ZJh mr-"C,( ,?If
Base Sheet Fastener/Bon�d}ng Materi 1•
\11 TYA,- -/ ;k,4 Ai9G r
Ply Sheet(s) & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
I
Top Ply:y�Ps/�4d 17® 6e
Top Ply FastenerBondin aterial•
1,1.45 2 04,0
�WAJA
i
Height j
i
C.AlvT'� !2 rim
FT
i s 10? -4
N- Mean
Height
2010 FLORIDA BUILDING CODE — BUILDING 15.35
MIAMI. MIAMI-DADE COUNTY
® PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY 11805 SW 26 Street, Room 208
AFFAIRS (PERA) Miami, Florida 331752474
BOARD AND CODE ADMINISTRATION DMSION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/vera
GAF Materials Corporation
1361 Alps Road
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami Dade County PERA —
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product
Control Section (In Miami—Dade County) and/or the AHJ (in areas other than Miami Dade County)
reserve the right to have this product or material tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their
jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Ruberoie Modified Bitumen Roof Systems for LWC Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, and
following statement: "Miami—Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement
of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure
to comply with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami—Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 08-0822.25 and consists of pages 1 through 27.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 12-0509.01
Expiration Date: 11/06/13
Approval Date: 07/12/12
Page 1 of 27
ROOFING SYSTEM APPROVAL
Category
Sub -Category
Materials:
Deck Type:
Maximum Design Pressure
Roofing
Modified Bitumen
APP/SBS
Lightweight Insulating Concrete
-112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Leak Buster Ma "" 3, 5, 55 gallons ASTM D 41 Asphalt concrete primer used to promote
307 Premium Asphalt adhesion of asphalt in built-up roofing.
Primer
Mineral Shield® Granules 5 gallon pails ASTM D 1863 Granules for surfacing of exposed
GAFGLAS® F1exPly 6
GAFGLAS® Ply 4
GAFGLAS® Mineral
Surfaced Cap Sheet
GAFGLAS® EnergyCap""
Mineral Surface Cap Sheet
39.37' (1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt
wide with asphalt coating.
39.37' (1 meter) ASTM D 2178 Type IV asphalt impregnated glass felt
wide with asphalt coating.
39.37' (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet
wide surfaced with mineral granules.
39.37' (1 meter) ASTM D 3909
wide Energystax7m
Title 24
Compliant
Asphalt coated, glass fiber mat cap sheet
surfaced with mineral granules with
factory applied EnergyCote7
NOA No.: 12-0509.01
Expiration Date: 11/06/13
MIAMI•DADE CoUNW Approval Date: 07/12/12
Page 2 of 27
asphalt, cold process cement or
emulsion. GAF Mineral Shield®
Granules shall be used for flashing
applications only.
Leak Buster Matrix""
5 gallons
ASTM 1227
Surface coating for smooth surfaced
305 Fibered Asphalt
roofs.
Emulsion
Leak Buster Matrix
1, 5 gallons
ASTM D 4586
Fibered aluminum coating.
303 Premium Aluminum
Roof Coating
Leak Buster"' Matrix'
1, 5 gallons
ASTM D 3019
Refined asphalt blended with a mineral
204 Wet/Dry Roof Cement
stabilizer and fibers. Permits adhesion to
wet and dry surfaces.
GAFGLAS® #75 Base
39.37" (1 meter)
ASTM D 4601
Type II asphalt impregnated and coated
Sheet
wide
glass mat base sheet.
GAFGLAS® #80 Ultima'
39.37' (1 meter)
ASTM D4601
Type II asphalt impregnated and coated
Base Sheet
wide
glass mat base sheet.
GAFGLAS® F1exPly 6
GAFGLAS® Ply 4
GAFGLAS® Mineral
Surfaced Cap Sheet
GAFGLAS® EnergyCap""
Mineral Surface Cap Sheet
39.37' (1 meter) ASTM D 2178 Type VI asphalt impregnated glass felt
wide with asphalt coating.
39.37' (1 meter) ASTM D 2178 Type IV asphalt impregnated glass felt
wide with asphalt coating.
39.37' (1 meter) ASTM D 3909 Asphalt coated, glass fiber mat cap sheet
wide surfaced with mineral granules.
39.37' (1 meter) ASTM D 3909
wide Energystax7m
Title 24
Compliant
Asphalt coated, glass fiber mat cap sheet
surfaced with mineral granules with
factory applied EnergyCote7
NOA No.: 12-0509.01
Expiration Date: 11/06/13
MIAMI•DADE CoUNW Approval Date: 07/12/12
Page 2 of 27
RUBEROID® SBS Heat- 39.37" (1 meter) ASTM D-6164 Non -Woven Polyester mat coated with
Weldm Smooth
wide
Test Product
Product
Dimensions
Specification Description
GAFGLAB�
39.37" (1 meter)
ASTM D 4897 Fiberglass base sheet coated on both
STRATAVENT®
wide
sides with asphalt. Surfaced on the
Eliminator Perforated
bottom side with mineral granules
RUBEROID" SBS Heat-
39.37" (1 meter) ASTM D-6164
embedded in asphaltic coating with
Weld" 170 FR
wide
factory perforations.
GAFGLAS®
39.37" (1 meter)
ASTM D 4897 Fiberglass base sheet coated on both
STRATAVENT®
wide
sides with asphalt. Surfaced on the
Eliminator Nailable
wide
bottom side with mineral granules
embedded in asphaltic coating.
RUBEROID® SBS Heat- 39.37" (1 meter) ASTM D-6164 Non -Woven Polyester mat coated with
Weldm Smooth
wide
polymer -modified asphalt and smooth
surfaced.
RUBEROID® SBS Heat-
39.37" (1 meter) ASTM D-6164
Non -Woven Polyester mat coated with
Weld° Granule
wide
polymer modified asphalt and surfaced
with mineral granules.
RUBEROID" SBS Heat-
39.37" (1 meter) ASTM D-6164
Non -Woven Polyester mat coated with
Weld" 170 FR
wide
fire retardant polymer modified asphalt
and surfaced with mineral granules.
RUBEROID® EnergyCapTm
39.37" (1 meter) ASTM D-6164
A fiberglass mat reinforced, SBS
SBS Heat -Weld' Plus FR
wide
modified bitumen cap membrane.
RUBEROID® SBS Heat- 39.37' (1 meter) ASTM D-6164 Non -Woven Polyester mat coated with
Weld? Plus wide polymer modified asphalt and surfaced
with mineral granules.
RUBEROID® SBS Heat- 39.37' (1 meter) ASTM D-6164 Non -Woven Polyester mat coated with
Weld° Plus FR wide fire retardant polymer modified asphalt
and surfaced with mineral granules.
RUBEROID® SBS Heat- 39.37' (1 meter) ASTM D-6163 A fiberglass mat reinforced SBS
Weld 25 wide modified base/ply membrane.
RUBEROID® EnergyCap 39.37' (1 meter) ASTM D-6163 A fiberglass mat reinforced, SBS
SBS 30 FR wide modified bitumen cap membrane.
RUBEROID® Mop 39.37' (1 meter) ASTM D 6164 Non -woven polyester mat coated with
Granule wide polymer modified asphalt and surfaced
with mineral granules.
RUBEROID® Mop Smooth 39.37' (1 meter) ASTM D 6164 Non -woven polyester mat coated with
wide polymer -modified asphalt and smooth
surfaced.
RUBEROID® Mop 170FR 39.37' (1 meter) ASTM D 6164 Non -Woven polyester mat coated with
wide fire retardant polymer modified asphalt
and surfaced with mineral granules.
RUBEROID® Mop FR 39.37' (1 meter) ASTM D 6164 Non -Woven polyester mat coated with
Wide fire retardant polymer modified asphalt
and surfaced with mineral granules.
NOA No.: 12-0509.01
Expiration Date: 11/06/13
MIAMHaME COUNTY Approval Date: 07/12/12
�rjalyi
Page 3 of 27
RUBEROID® Torch FR
RUBEROID® 20
RUBEROID® 30
RUBEROID® 30 FR
RUBEROID® Dual FR
RoofMatch7
APP Granular
RoofMatch7
SBS Granular
M -Weld® MDrain
M -Weld® MScupper
M -Weld Standard,
Adjustable, One Way
Went
Leak Buster Matrix"
304 Non-Fibered
Aluminum Roof Coating
Leak Buster'" Matrix"'
201 Premium SBS Flashing
Cement
Leak Buster Matrix"°
102 SBS Membrane
Adhesive
39.37" (1 meter) ASTM D 6222
wide
39.37' (1 meter) ASTM D 6163
wide
39.37' (1 meter) ASTM D 6163
wide
39.37' (1 meter) ASTM D 6163
wide
39.37' (1 meter) ASTM D 6162
Wide
Heavy duty, polyester reinforced, coated
with fire retardant asphalt modified
bitumen membrane, granule surface.
SBS modified asphalt base sheet
reinforce with a glass fiber mat.
Non woven fiberglass mat coated with
polymer modified asphalt and surfaced
with mineral granules.
Non woven fiberglass mat coated with
fire retardant, polymer modified asphalt
and surfaced with mineral granules.
Non -woven polyester and fiberglass mat
coated with fire retardant, polymer -
modified asphalt and surfaced with
mineral granules.
39.37' (1 meter) ASTM D 6222 Non -woven polyester mat coated with
wide polymer modified asphalt and surfaced
with colored mineral granules.
39.37' (1 meter) ASTM D 6164
wide
various
various
various
5 gallons
5 gallons
5 gallons
proprietary
Non -woven polyester mat coated with
polymer modified asphalt and surfaced
with colored mineral granules.
Spun aluminum or copper roof drain.
proprietary Prefabricated scupper.
proprietary Prefabricated stack cover for use in soil
pipe waterproofing.
ASTM D2824, Non-fibered. Aluminum pigmented,
Type I asphalt roof coating
ASTM D3019 Cold Applied Modified SEBS Asphalt
Adhesive — Flashing Grade.
ASTM D3019 Cold Applied Modified SEBS Asphalt
Adhesive.
NOA No.: 12-0509.01
Expiration Date: 11/06/13
Approval Date: 07/12/12
Page 4 of 27
Test
Product
Product
Dimensions
Specification
Description
RUBEROII�orT ch
39.37" (1 meter)
ASTM D 6222
Heavy duty, polyester reinforced, asphalt
Smooth
wide
modified bitumen membrane, smooth
surface.
RUBEROID® Torch
39.37" (1 meter)
ASTM D 6222
Heavy duty, polyester reinforced, asphalt
Granule
wide
modified bitumen membrane, granule
surface.
RUBEROID® Torch FR
RUBEROID® 20
RUBEROID® 30
RUBEROID® 30 FR
RUBEROID® Dual FR
RoofMatch7
APP Granular
RoofMatch7
SBS Granular
M -Weld® MDrain
M -Weld® MScupper
M -Weld Standard,
Adjustable, One Way
Went
Leak Buster Matrix"
304 Non-Fibered
Aluminum Roof Coating
Leak Buster'" Matrix"'
201 Premium SBS Flashing
Cement
Leak Buster Matrix"°
102 SBS Membrane
Adhesive
39.37" (1 meter) ASTM D 6222
wide
39.37' (1 meter) ASTM D 6163
wide
39.37' (1 meter) ASTM D 6163
wide
39.37' (1 meter) ASTM D 6163
wide
39.37' (1 meter) ASTM D 6162
Wide
Heavy duty, polyester reinforced, coated
with fire retardant asphalt modified
bitumen membrane, granule surface.
SBS modified asphalt base sheet
reinforce with a glass fiber mat.
Non woven fiberglass mat coated with
polymer modified asphalt and surfaced
with mineral granules.
Non woven fiberglass mat coated with
fire retardant, polymer modified asphalt
and surfaced with mineral granules.
Non -woven polyester and fiberglass mat
coated with fire retardant, polymer -
modified asphalt and surfaced with
mineral granules.
39.37' (1 meter) ASTM D 6222 Non -woven polyester mat coated with
wide polymer modified asphalt and surfaced
with colored mineral granules.
39.37' (1 meter) ASTM D 6164
wide
various
various
various
5 gallons
5 gallons
5 gallons
proprietary
Non -woven polyester mat coated with
polymer modified asphalt and surfaced
with colored mineral granules.
Spun aluminum or copper roof drain.
proprietary Prefabricated scupper.
proprietary Prefabricated stack cover for use in soil
pipe waterproofing.
ASTM D2824, Non-fibered. Aluminum pigmented,
Type I asphalt roof coating
ASTM D3019 Cold Applied Modified SEBS Asphalt
Adhesive — Flashing Grade.
ASTM D3019 Cold Applied Modified SEBS Asphalt
Adhesive.
NOA No.: 12-0509.01
Expiration Date: 11/06/13
Approval Date: 07/12/12
Page 4 of 27
Boards
NOA No.: 12-0509.01
Expiration Date: 11/06/13
MIMMECOUNWM Approval Date: 07/12/12
�-
Page 5 of 27
Test Product
Product
Dimensions Specification Description
Leak Buster ` Matrix-
5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt
202 SBS Flashing Cement
Adhesive — Flashing Grade.
Leak Buster Matrix
5 gallons ASTM D4586 Standard Plastic Asphalt Roofing
203 Plastic Roof Cement
Cement
Leak Buster" Matrix
5 gallons ASTM D3019 Cold Applied Asphalt Adhesive.
103 Cold Process Adhesive
TOPCOAT® Fireshield SB
ASTM D-6083 Solvent based liquid thermoplastic
rubber sealant designed to restore roof
surfaces, formulated to provide fire
protection and to increase a roof's
reflectivity.
EnergyCote7 Roof Coating
proprietary Surface coating for smooth surfaced and
mineral surfaced roofs.
TOPCOAT®
ASTM D-6083 Solvent based sprayable thermoplastic
Surface Seal SB
rubber sealant used to protect and restore
aged roof surfaces and to increase a a
roofs reflectivity.
APPROVED INSULATIONS:
TABLE 2
Product Name
Product Description Manufacturer
(With Current NOA)
EnergyGuard m,
Polyisocyanurate foam insulation GAF Materials Corp.
EnergyGuard'm RA,
EnergyGuard7 RN
EnergyGuard7 Composite,
Polyisocyanurate foam insulation with GAF Materials Corp.
EnergyGuard - Composite RA
high density fiberboard or perlite
EnergyGuard7 Composite RN
insulation.
EnergyGuard7 Perlite
Perlite insulation board. GAF Materials Corp.
DensDecV Roof Board
Gypsum board G -P Gypsum Corp.
Securocko
High Density Fire Resistant Insulation USG
Boards
NOA No.: 12-0509.01
Expiration Date: 11/06/13
MIMMECOUNWM Approval Date: 07/12/12
�-
Page 5 of 27
Membrane Type: SBS/SBS Heat Weld
Deck Type 4I: Lightweight Concrete, Insulated, (See System Limitation)
Deck Description: Cellular or Aggregate Lightweight Concrete
System Type A(4): Anchor sheet mechanically fastened; one or more layers of insulation adhered with
approved asphalt.
All General and System Limitations shall apply.
Anchor Sheet: Install one ply of GAFGLAS® #75 Base Sheet, GAFGLAS® #80 Ultima? Base
Sheet, GAFGLAS® STRATAVENT® Eliminator Nailable, RUBEROID® Mop
Smooth or RUBEROID® 20 mechanically fastened as described below.
Fasteners: Drill-Tec"m CR Base Sheet Fasteners at a fastener spacing of 7.5" o.c. at the 3" wide
side laps and 7.5" o.c. in two equally spaced rows in the field of the base sheet.
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/fe
EnergyGuard"' Composite, EnergyGuard7 Composite RN, EnergyGuar(r Composite RA,
EnergyGuard7 RA, EnergyGuard7 RN
Minimum 1 %2" thick N/A N/A
EnergyGuard7 Perlite, DensDecV, Securock
Minimum %2" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt
within the EVT range and at a rate of 2040 lbs. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Composite insulation panels may be used as a top layer placed with
the Polyisocyanurate side facing down.
Base Sheet: One ply of RUBEROID® 20, GAFGLAS® Ply 4, GAFGLAS® FlexPly 6,
GAFGLAS® STRATAVENT® Eliminator Perforated (laid dry), GAFGLAS® #80
Ultima"' Base Sheet, RUBEROID® Mop Smooth or GAFGLAS® #75 Base Sheet
adhered to the insulation in a full mopping of an approved asphalt at an application
rate of 251bs./sq. f 15%; see General Limitation #4.
Ply Sheet: (Optional) One or more plies of GAFGLAS® #75 Base Sheet, GAFGLAS® # 80
Ultima' Base Sheet, RUBEROID® 20, RUBEROID® Mop Smooth, GAFGLAS® Ply
4 or GAFGLAS® F1exP1y"m 6 in an approved asphalt at an application rate of 25
lb./sq. f 15%.
Membrane: One or more plies of RUBEROID® 20, RUBEROID® 30, RUBEROID® 30 FR,
RUBEROID®EnergyCap SBS 30 FR, RUBEROID® Mop Smooth, RUBEROID®
Mop 170 FR, RUBEROID® Mop Granule, RUBEROID® Mop FR, RUBEROID®
Dual FR or Roof Match"" SBS Granular fully adhered in type III or IV of an
approved asphalt at an application rate 2040 lbs./sq. or Matrix 102 at an application
rate or 1 gallon/sq.
Or
RUBEROID® SBS Heat -Weld' Smooth, RUBEROID® SBS Heat -Weld' Plus,
RUBEROID® SBS Heat -Weld"" Plus FR, RUBEROID® SBS Heat -Weld` 25,
RUBEROID® SBS Heat -Weld' Granule, RUBEROID® SBS Heat -Weld' 170 FR or
RUBEROID® EnergyCap SBS Heat Weld Plus FR applied according to
manufacturer's application instructions.
Surfacing: (Optional, required over RUBEROID® Torch Smooth, RUBEROID® SBS Heat -
Weld Smooth or RUBEROID® SBS Heat -Weld' 25). See Table 4 for options.
Maximum Design
Pressure: -75 psf (See General Limitation #7)
NOA No.: 12-0509.01
Expiration Date: 11/06/13
MIAM10ADE COUNTYIE Approval Date: 07/12/12
Page 13 of 27
LIGHTWEIGHT INSULATING CONCRETE SYSTEM LIMITATIONS:
1. If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field
withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All
testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application
Standard RAS 117, calculations shall be signed and sealed by a Florida registered Professional Engineer, Registered
Architect, or Registered Roof Consultant.
2. For steel deck application where specific deck construction is not referenced: The deck shall be a minimum 22 gauge
attached with 5/8" puddle welds with weld washers at every flute with maximum deck spans of 5 ft. o.c.
3. For systems where specific lightweight insulating concrete is not referenced, the minimum design mix shall be a
minimum of 250 psi.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings
of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be
4'x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when
the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with
approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one
down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6"
break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at
a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45
psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in
compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf.
insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared,
signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said
revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105
and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities
shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS
117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or
Registered Roof Consultant (When this limitation is specifically referred within this NOA, General
Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and
corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones
(i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA,
General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-
3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 12-0509.01
Expiration Date: 11/06/13
Muar WME eounrnr Approval Date: 07/12/12
•
Page 27 of 27
2007 ROOFING MATERIALS AND'SYSTENIS`DIRECTORY
192, ROOF COVERING MATERIALS (TEV')
Roofing Systems (TGFU)—Continued
Base Corti "A-38 Series•", 0.75 gal/sq.
Second Base Coat: "A-38 Series", 0.75 gal/sq.
Wear Coat: "A-38 Series ", 0.75 gal/sq plus walnut shells at 0.75 lbs per
sl -
Surfacing: "A.--38 Series ", 0.75 gal/sq plus walnut shells at 0,75 lbs per
sq.
46 Deck: NCIncline: 3/4
Foam: Spray application of 2 -in thick "Polyfoam 273" (2.71b/ft.3 )
Surfacing. Spray application of 28 to, 34 -mils "U-8730" (alumin%un)
47 Deck: NC` Incline: 1/2
Insulation: Spray application of 2 -in. thick "Polyfoam 273" (2.7.Ib/ft.3
Surfacing: Spray application of 28 to 34 -mils "U-8782" (ivory)
GAF MRIALS`ORP R1306
1361 f k RD, WAYNE NJ 07470
"Ruberoid 20" or "Ruberoid Modified Base Sheet" may be utilized. as an
alternate to Type G2 base sheets in any of the following Classificatioris.
1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G-P'gypsum
re=
may be used in any existing noncombustible deck Classification.
When this is done, the resulting roofing system is acceptable for use over
combustible (15/32 in. min) roof decks. The Joints'in the gypsum board and
overlayment board are offset 6 in. with the joints in the deck. If polystyrene is
part of the roof system, it must be placed below the overlayment board.
Also, multiple plies of "GAFGLAS Ply 4" or `Ply 6" may be adhered to G -P
Gypsum DensDeck@ in hot asphalt.
"EnergyGuard Ultra" is an acceptable alternate to "EnergyGuard" in any
applicable Classification.
' GAF Stratavent Eliminator Venting Base Sheet (Nailable)" may be mechani-
cally attached or hot mopped over noncombustible decks and as a recover over
existing roof systems.
GAFGLAS Perlite Insulation may be utilized as a cover board over "EVER -
GUARD" insulation in any of the following systems.
Unless otherwise indicated, the roof insulation is mechanically fastened,
adhered' with hot mopping asphalt or urethane insulation adhesive. Polystyty
rene reference in any of the following Classficatons include "EIVERGuard EPS
Insulation".
References to glass fiber insulation include "EnergyGuard Fiberglass Insu-
lation".
ASPHALT,,F T. SYSTEMS WITH HOT ROOFING ASPHALT
Type G2 asphalt � mat base sheet ("GAFGLAS 475 Base Sheet" or
GAA�TGLAS ##8800 UL ' ) is a suitable alternate for Type G1 asphalt glass
fiber ply sheet ("GAFGLAS Ply 4" or "GAFGLAS Ply 6") in the Class A, B or
C roof`systems'indicated below.
The'robf'deck may first'be`covered with a Type G2 asphalt glass mat base
sheet "GAF Stratavent Eliminator Ventuig Base Sheet (Perforated)S' or "GAF
Strata�tent Eliriiiinator Venting Base Sheet (Nailable)".. Perforated to be
mopped and nailable to be mechanically attached granule side down.
As an,o ,,tionFType G2 as halt glass •rriat base sheet ("GAFGLAS #75 Base
Sheet", "GAFGLAS #80 ULTIMA or "GAF Stratavent Eliminator Venting Base
Sheet (Naila6leJ". may: be substituted for G1 asphalt glass fiber ply sheet
("GAFGLAS Ply 4" .or "GAFGLAS Ply 6") as the nailed base ply in the
following systems.
Bottom ply, or base sheet may be solid mopped, spot mopped or mechani-
cally fastened.,
ti ild04ot1'l�ivise indicated, allinsulations may be hot mopped or mechani-
callpp fastened
"GAFGLAS Flashing" or "Ruberoid" may be'used for flashing in any of the
Class A, B or C systems listed below. I r '
When "perlite" is referenced, this includes "GAFTF,MP PERMALITEO" or
any other UL Classified perlite insulation. ,
Crushed stone or slag are suitable. alternates for gravel in any of the. Class A,
B or C systems listed.
Structural cement fiber buildinunits are considered suitable to be included
as a deck in the following Class't•B. or C systems, listed over C-15/32 or NC.
The use of gypsum board under' of the following Class A, B oz`C `systems
does not adversel} ,6&ict the rating. The use of 1/2 in. min gypsum board is an
acceptable alternate for insulation over C-15/32 decks:
The use;of;polystyrene.-insulation board between min 3/4 in. perlite board
and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a
suitable alternate for isocyanurate board in the following Class A, B or C
systems.
BMCA EnergyGuard RA", "BMCA Tapered EnergyGuard RK' and '.'BMCA
EnerpGuard may be substituted for -any Atlas polyisocyanurate insula-
tion in any of the following Classifications.
Trumbull "Perms Mop" may be utilized with any of the following `'Asphalt
Felt Systems with Hot Roofing Asphalt".
GAFGLAS #80 Premium Base Sheet may be used in any of the following
systems.
"GAFGLAS Flex Ply 6" is a suitable alternate to "GAFGLAS Ply 6".
COVF�)ING
Roofing Systems (TGFU)—Continued
"GAFPEMP Permalite Recover ;Board" may be used in lieu of any, perlite
insulation in any of the followrng..NC; Classifications.
Unless otherwise indicated, any of the "Asphalt Felt Systems with Hol
Roofing Asphalt" may be surfaced, with "Fireshidd MB" at 25,- 3.0 gal/sq.
Class A.
Hot roofing asphalt, for use with organic and glass felts or, modified bitumen
membranes.
"Ruberoid Heat, Weld" SBS roofing, membrane may be used in, lieu of
"Ruberoid Mop" SBS products in any applicable Classification.'
Class A
l 3.
7.
Deck: C-15/32 Incline: 3
Insulation,(Optional): One or more layers perlite, wood fiber, gla
fiber, isocyanurate, urethane, perlite/isocyanurate composite,. perlite
urethane composite, wood fiber/isocyanurate composite, phenolic, ar
thickness
Ply Sheet: Three or more layers Type GI "GAFGLAS Ply .4" i
"GAFGLAS Ply 6", hot mopped.
Surfacing. Gravel.
Deck: C-15/32 Incline: 2
Insulation (Optional):/ One or more layers perlite, wood fiber, gla
fiber, isocyam irate, urethane, perlite/isocyanurate composite, perlite
iWthane composite, wood fiber/isocyanurate composite, phenolic, ar
thickness
Ply Sheet:' Three or more layers Type G1 "GAFGLAS Ply 4" 1
"GAFGLAS Ply 6".
Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Ca
Sheet" or "EnergyCap Mineral Surfaced Cap Sheet".
Deck: NC Incline: 2
Insulation (Optional): One or more layers perlite, wood fiber, gla
fiber, isocyanurate, urethane, perlite/isocyanurate composite, perlite
urethane composite, wool fiber/isocyanuate composite, phenolic, 2 i
max..
Ply Sheet *oi or more layers Type GI "GAFGLAS Ply 4" or "GA1
GLAS Ply 6".''
Cap Sheet: One layer Type G3 GAFGLAS Mineral. Surfaced Ca
Sheet" or "EnergyCap Mineral Surfaced Cap Sheet".
Deck NC Incline: 1/2 -
Insulation: One or two layers "Isotherm R", 4 in. max, hot mopped.
Ply Sheet: Any UL Classified gravel surfaced Class A asphalt glass fib
mat system.
Deck: C-15/32 In -dine: 1 -
Slip Sheet (Optional): Red rosin paper, nailed to deck.
Base Sheet: One layer Type G2 "GAFGLAS #75 Base Sheet" (may 1
nailed).
Ply Sheet:. One or more layers Type Gl "GAFGLAS Ply 4" or GAFGLA
Ply 6"..
Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced CO
Sheet" or "EnergyCap Mineral Surfaced Cap Sheet".
Deck: NC Iodine: 3
Base Sheet: One layer Type G2 "GAFGLAS #75 Base Sheet
Ply Sheet: One or more layers Type GI "GAFGLAS Ply 4" -or "GAJ
GLAS Ply 6".
Cap Sheet: One layer Type G3 "GAFGLAS Mineral Surfaced Q
Sheet" or "EnergyCap Mineral Surfaced Cap Sheet".
Deck: C-15/32 Incline: 2
Insulation: One or more layers perlite; glass.fiben' isccyant rate; un
thane, perlite/isocyanumte composite; perlite/urethane conpc site, ph
nolic, 1.0 in. min (offset. from plywodd joints 6 in:): ?
Base Sheet: One or more layers Type G1; G2 or G3,
Membrane: One or more layers 'Ruberoid Torch" (Smooth or Gr**
"Ruberoid Torch Plus" (granule), "Ruberoid Mop" (Smooth or Grams"
or "Ruberoid Mop Plus" (granule). '
Cap Sheet: Type G3 "GAPGLAS Mineral Surfaced, Cap Sheet'
"EnergyCap Mineral Surfaced Cap Sheet", hot mopped. `
Deck: C-15/32- Incline; 2 i
Insulation (Optional): One or more layers perlite, wood fiber,. gla,'
fiber, isocyanurate, urethane, perlite/isocyanurate composite; perlite
urethane composite, wood fiber/isocyanurate composite, phenolic, at
thickness.
Base Sheet: Two or more layers Type G2 or G3.
Ply Sheet (Optional): One or more layers Type Gl.
Membrane: ,One or more,layers "Ruberoid Torch" (ooth or -Granule
"Ruberoid Torch PIus`•',`;(gr nule), "Ruberoid Mop" (Smooth or. Gran)
or "Ruberoid Mop,tIM41;(granule).
2007' ROOFING MATERIALS
194 ROOF COVERING MATERIALS
Roofing Systems (TGFU)—Continued
3. Deck: C-15/32 Incline: Unlimited
Insulation (Optional): One or more layers perlite, wood fiber, glass
fiber,isocyanurate; urethane, perlite/isocyanurate composite, perlite/
urethane composite, wood fiber/isocyanurate composite; phenolic, any
thickness.
Ply Sheet: Three or more -layers Type Gl "GAFGLAS Ply 4" or
"GAFGLAS Ply 6".
Surfacing: "Weather Coat Emulsion" at 3 gal/sq.
FLUIl3'APPLIED COATING SYSTEM
1. Deck: NC Incline: Unlimited
Surfacing: "Weathercote Low VOC" or "Weathercote" - 2 gal/sq.
SINGLE PLY MEMBRANE ROOFING SYSTEMS (MODIFIED
BITUMEN)
Unless otherwise indicated phenolic insulation may be used in any of the
following systems.
Unless otherwise indicated any of the following Single Ply Membrane
Systems may utilize multiple la efs of Ruberoid Membrane.
"GAF Premium Aluminum Roof Coatin4" may be used on any of the
following Classifications not exceeding 1/2 in.
"GAF Weater Coat Emulsion" may be used on any of the following
noncombustible. Classifications not exceeding 1/2 in.
Ruberoid® Modified Bitumen Adhesive, Monsey Corp "MBA Gold" and
Karnak "No $1" adhesives may be used in any of the following noncombus-
tible deck Classifications.
Tropical'Asphalt "No. 711 AF" adhesive may be used in any of the following
Classifications.
GAFGLAS #80 Premium Base Sheet may be used in any of the following
systems.
(Optional) Noncombustible deck classifications are applicable for use over
combustible (15/32 in. min plywood) decks when 1/2 in. (min) gypsum board
or 1/4 in: (min) G -P Gypsum DensDeck® are used directly over the deck with
all joints staggered 6 in. (min) from plywood joints.
A vapor barripr may be optionally installed under all systems utilizing
"EVERGUARD" insulation. "EVERGUARD" insulation is an acceptable
alteniat,bt any pcjlyisocyanurate insulation of the following systems. .GAF-
GLAS Perlite may be used as an option over EVERGUARD insulation. GAF-
GLAS Stratav . t Perforated Base Sheet may be utilized as an additional ply
in' any of thefollowing systems.
The following membranes may be used interchangeably within their own
group:
A. Ruberoid Torch Granule", "Ruberoid Torch Granule Plus", "Ruberoid
Torch Granule 1", Ruberoid Torch 180.
B. "Ruberoid Mop Smooth", "SBS HW Smooth", "Ruberoid 601 Cap Plus",
"Ruberoid 30" .
C. 'Ruberoid Mop Granule", "Ruberoid Mop Plus Granule", "SBS HW
Granule", "SBS HW Plus".
D. "Ruberoid Mop 170 FR (1 sq)", "Ruberoid Mop 170 FR (1/2 sq)"
E. "Ruberoid Mop FR 2", Ruberoid 30 FR", "Ruberoid SBS Heat Weld 170
FR":
F 'Ruberoid 20", "SBS HW (Heat Weld) 25":
G "Flame Fiee :180 FR", " Ruberoid Torch FR", "Brai Supreme Plus APP
Granule FR'; "GBSP-250FR", "Brai Supreme -APP Granule FR" .
Unless otherwise intlic �ggdcl-., the Modified Bitumen (Granule) membrane may
be surfaced writh "FiresM Id SIR" at 2.5 _ 3.0 dal/sq,, and the incline of the
resultant system would be increased to a'3/4 in. incline. But if the incline of the
Classified system is Greater than a 3/4 in incline, the incline of the roofing
system would be maintained when surfaced with "Fireshield MB" at, 2.5 — 3.0
g
al/
Unless otherwise indicated'Ruberoid EnergyCap SBS 30FR" is an acceptable
alternate for "Ruberoid 30 FR" or "Ruberoid Mop 170 FR" in any applicable
Classification.
Class A - Ballasted
1. Deck: NC Incline: 2
Insulation: One or two layer's "Isotherm R", any thickness, loose laid or
mechanically, fastened.
Membrane: ' Any UL Classified membrane used -in a ballestesystem.
Surfacing. River bottom stone, 3/4 to 1-1/2 in. dram, 1000 lbs/ -
2. Deck: -C-15/32 =,Incline: 1/4
Insulation: Perlite, glass fiber•ot wood'fiber,3/4 to
Membrane: "Ruberoid Torch Granule 1" (modified bitur
Surfacing Gravel at 400 lbs/sq, loose 1<• ^^nc -,e blocks, at 10
lbs/sq and spaced not more than I/8 ;Incline: 3
3. Deck NC Jber or wood fiber, 3/4 to,1-1/2 in.
Insulation (Optional): Perlite,.glm halt orgardc felt or `Type G2.
Base Sheet (Optional). Type 15,asUe 1 (modifiedibitumen)'.
Membrane: ."Ruberoid Torch Grar
Surfacing: Gravel Inc ine:l/4
4. Deck: C-15/32
l
rid►..; nrsehx►�si`ov
ROOF COVERINGIMATERIALS (TEV
Roofing Systems (TW—Continued
- -Insul'atidn (Optional): Perlite, glassa*r or wood fiber, any thickne
Membrane: "Ruberoid Torch Granute 1Y (modified bitumen).
Slip Sheet: 0.004 in: polyethylene (not UL Classified).
Surfacing- 3/44n. thick concrete with'onejayer of_No.10 Summervi
Quarry tile (or equivalent) grouted in place. .
5. Deck: NC ,Incline: 2 u,
Insulation (Optional): Perlite, glass fiber or wood fiber;: any thicknc
Membrane: ''Ruberoid Torch Granule 1" (modified -bitumen).
Surfacing- 3/4'to 1-1/2 in. diam river bottom stone at 1000 Ib/sq
concrete pavers weighing not less than 10 lb/sq ft and spaced not• w
than 1/8 in.
6. Deck: NC Incline: 3
Insulation: a)Polystyrene, 2 in. max, b)lsocyanurate; any thickness, L
loosely.
Membrane: "EverGuard SR" or "EverGuard FB", 40-100 mil (TPA), L
loosely.
Surfacing: River bottom stone (3/4 - 1-1/2 in. diam) at 1000 lb/sq
concrete roof pavers.
7. Deck: C-15/32 Incline- 1/2
Slip Sheet: One or more layers Atlas Roofing "FR50", mechanica
`fastened.
Membrane: "EverGuard TP02 Plus", 45 mil.
Surfacing- River bottom stone, (3/4 to 1-1/2in. diam) at 10001bs/sq
concrete roof pavers.
8. Deck: C-15/32 Incline: 1/2
Base Sheet: Two or more layers Type G2, "GAFGLAS Basesheet #7
mechanically fastened.
Membrane: "EverGuard TP02 Plus", 45 mil.
Surfacing. River bottom stone, (3/4 to 1-1/2 in. diam) at 10001bs/sq
concrete roof pavers.
Class A JulIy Adiigired
1. Deck: NC Yt1/2
Insulation (Optional) One or more layers perlite, wood fiber,; g1
fiber, isocyanurate, urethane, perlite/isocyanurate composite, perfit
urethane' composite; wood fiber/isocyanurate`coinposite, phenolic, a
thickness.
Base Sheet (Optional): One or more layers Type GI, G2 or G3 b'
Membrane: One or more layers "Ruberoid Torch" (Smooth or Grams;
"Ruberoid Torch Granule Plus", "Ruberoid Mop" (Smooth or Grana
or "Ruberoid Mop Plus Granule" (granule).
Surfacing- Gravel, 400 lbs/sq, loose laid or applied in a flood coat of
roofing asphalt: s t
2. Deck: NC Incline: 1/2
Base Sheet (Optional): One or more layers Type Gl, G2 or G3'
Membrane: One or more layers "Ruberoid Torch" (Smooth or Gran'
"Ruberoid Torch Granule Plus', 'Ruber6ffi Mop" -(Smooth of Gram
or "Ruberoid Mop Plus Granule". � i
Coating: Karnak No. 97,1-1/2 - 3 gal/sq.
3. Deck: NC Incline: 1/4 31
Insulation (Optional): One or more layers perlite, wood fiber,
fiber, any thickness. r,
Base Sheet (Op`66rW):' One or more layers Type Gl, G2 or G3
Membrane: One or more layers "Ruberoid Torch" (Smooth or Grana
"Ruberoid Torch GranulePlus", "Ruberoid Mop Granule" or R
Mop Plus Granule"
Coating: Karnak No. 97,1-1/2 - 3 gal/sq.
4. Deck: C-15/32 Indine:1/2
w,.
Insulation: One or more layers perlite, glass fiber, isocyanurate,n
thane; perlite/isocyanurate composite, perlite/urethane coin .i"'
nolic, 1-1/2 in. min thickness (offset fromplywood joints',6 m) W
Base Sheet: One or, more, layers Type G2 or G3. nA)
Ply Sheet (Optional): One or4nore layers Type. Gl.
M'embraste: One or more layer "Rubeift�1�forch'.: (Smooth orGra(}
„Ruben id).fiorch Granule Plus'; "Ruben d��(5mooth or
I.''V+ibemid, Mop Plus Granule". R
$rr6acrng:•-7raak, No 97,1;;1'/2 - 3 gal/sq: °
5 Deek:- NC Incline: 1/2 �>
Base Sheet (Op eroi } One or more layers TypeGl G2 or G3
Menibiane C�ra0ior > t f Qroid Tod' (Smoptl► or G '
TIM,! or '169'S',at'.10 gal/
4 dut ;Incl feel llrtu
2007':ROOFING MATERIALS ANDSYSTEMSyDIRECTORY
ROOF COVERING MATERIALS
Roofing Systems (TGFU)—Continued
Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocya-
nurate, urethane, perlite/isocyanurate composite, perlite/urethane com-
+sposite, l-1/2 in. min.
Base Sheet (Optional): One or more layers Type GI, G2 or G3.
11r Membrane: One or more layers 'Ruberoid Torch" (Smooth or Granule),
"Ruberoid Torch Granule Plus", "Ruberoid Mop" (Smooth or Granule)
or "Ruberoid Mop Plus Granule".
Surfacing: Gravel.
Meck: C-15/32 Incline: 1/2
i:lnsulation (Optional): One or more layers perlite, wood fiber, glass
fber, isocyanurate, urethane, perlite/isocyanurate composite, perlite/
urethane composite, wood fiber/isocyanurate composite.
.Base Sheet: Two or more layers Type G2 or G3.
a Ply Sheet (Optional): One or more layers Type G1.
Membrane: One or more layers "Rubeloid Torch" (Smooth or Granule),
"Ruberoid Torch Granule Plus", "Ruberoid Mop" (Smooth or Granule)
or 'Ruberoid Mop Plus Granule".
Surfacing. Karnak No. 97,1-1/2 - 3 gal/sq or gravel.
Deck: NC Incline: 1/2
Insulation: One or more layers perlite, glass fiber, 3/4 in. min, isocya-
nurate, urethane, perlite/isocyanurate composite, perlite/urethane com-
posite, 1-1/2 in. min.
Base Sheet (Optional): One or more layers Type Gl, G2 or G3.
Membrane: One or more layers "Ruberoid Torch" (Smooth or Granule),
"Ruberoid Torch Granule Plus", "Ruberoid Mop" (Smooth or Granule)
or "Ruberoid Mop Plus Granule".
Surfacing. Grundy "AL MB Aluminum Roof Coating" at 1-2 gal/sq.
Deck. C-15/32 Incline: 1/2
Insulation (Optional): One or more layers perlite, glass fiber, 3/4 in.
min, isocyanurate, urethane, perlite/isocyanurate composite, perfite/
urethane composite, phenolic, 1-1/2 in. min.
Base Sheet: One or more layers Type G2 "GAFGLAS #75 Base Sheet",
hot mopped or mechanically fastened in place.
Ply Sheet: One or more layers Type G1 "GAFGLAS Ply 4", hot mopped
in place.
Membrane: "Ruberoid Mop 170 FR".
Surfacing (Optional): GAF Fibered Aluminum Coating" at 1-1/2
gal/sq or "GAF Weather Coat Emulsion" at 3 gal/sq.
Deleted ,
Deleted
Deleted
Deleted
DIc1C+tr=15/32 "- Incline: 1/2
Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane or
perfite/isocyanurate composite.
Base Sheet: One or more layers Type G2 or G3 base sheetrhot mopped
or mechanically fastened.
Ply Sheet (Optional): One or more layers Type Gl, hot mopped in
place.
-Membrane:x. "RuberoidrMop 170 FR".
Deck: C-15/32_.: Incline: 1/2
Insulation (Optional): Perlite, fiber glass, isocyanurate, urethane or
perlite/isocyanurate composite, offset 6 in. from joints.
Base Sheet: One ormore layers Type G-2 or G-3 base sheet, hot mopped
or, mechanically fastened.
Ply Sheet (Optional): One or more layers Type G-1, hot mopped yin
place.
Membrane: One layer "Ruberoid Torch Smooth" or "Ruberoid Mop
Smooth".
Membrane: One layer "Ruberoid Mop 170 FR".
Deck: NC Incline: 1
Insulation (Optional):. Perlite, fiber: glass, .wood fiber, isocyanurate,
urethane or perlite/isocyanurate composite.
Base Sheet: One or more layers Type G2 -or G3 base sheet, hot mopped
or mechanically fastened.
Ply Sheet (Optional): One or more layers Type Gl, hot mopped in
place.
Membrane: One layer "Ruberoid Mop 170 FR" -
Deck: NC Incline: 1/2
Insulation (Optional): Perlite, fiber glass, wood, fiber, isocyahurate,
urethane or perlite/isocyanurate composite.
Base Sheet (Optional): One or more layers Type G2 or G-3 base sheet,
hot mopped or mechanically fastened.
ROOF COVERING MATERIALS (TEVT) 195
Roofing Systems (TGM—Continued
Ply Sheet (Optional): One or more layers Type Gl, hot mopped in
place.
Membrane: One layer "Ruberoid Torch Smooth" (smooth), "Ruberoid
Mop Smooth".
Membrane: One layer "Ruberoid Mop 170 FR" (granule).
19. Deck: NC Incline: 1/2_
Insulation (Optional): One or more layers perlite, glass..fiber, isocya-
nurate, urethane or perlite/isocyanurate composite any thickness.
Base Sheet: One or more plies4ype G1 or G2, hot mopped or adhered
with Karnak Chemical "No. 81"' or Gibson -Homan "No. 6160" cold
applied adhesive at 1-1/2 gal/sq,,
Membrane: One layer "Ruberoid Mop 170 FR", hot mopped or adhered
with Karnak Chemical "No. 81" or Gibson -Homan "No. 6160" cold
applied adhesive at 1-1/2 gal/sq.
20. Deleted
21. Deck: C-15/32 Incline. 1/2 -
Insulation (Optional): Polyisocyanurate, wood fib&q perllite, glass fiber
any thickness, hot mopped or mecha*,Wlly fastened.
Base Sheet: One or more plies Type G2 "GAFGLAS #75" base sheets,
hot mopped or mechanically fastened.
Membrane: One or more plies "Ruberoid 30 FR" hot mopped in place.
22. Deck. C-15/32 Incline: 1/2
Insulation (Optional): Polyisocyanurate, wood fiber, perfite, or glass
fiber any thickness, hot mopped or mechanically fastened.
Base Sheet: One or more plies Type G2 "GAFGLAS #75" hot mopped
or mechanically fastened.
Ply Sheet: One or more plies "Ruberoid 20", hot mopped in place.
Membrane: One or more plies "Ruberoid 30 FR", hot mopped: in place.
23. Deck: C-15/32 Incline: 1/2 1, f
Insulation (Optional): Fiber glass or perlite, mechanically fastened.
Base Sheet: One or more layers Type G2, hot mopped or mechanically
fastened. J.
Ply Sheet: Two or more layers Type Gl, hot mopped or mechanically
fastened. _.
Membrane: "Ruberoid 30" or "Ruberoid Modified Cap Sheet 601", hot
mopped in place.
Surfacing. Karnak Chemical "Karnak No. 97 Fibrated'.Aluminum
Asphalt Roof Coating" or "Karnak No. 97 Asbestos Flee Aluminum Roof
Coating" at 1 to 2 gal/sq. , ..
24. Deck: NC Incline: 1/4
Insulation (Optional): Polyisocyanurate, perlite, glass fiber oe.-wood
fiber, 2 in. max.
Base Sheet: Type 15 asphalt organic felt or 'Type G2, mechanically
fastened or adhered with hot roofing asphalt.
Membrane: "Ruberoid Torch Granule 1" (modified bitumen).
Surfacing. Karnak Chemical "Karnak No. 97 Fibrated Aluminum
Asphalt Roof Coating" or "KarnakNo. 97 Asbestos Free Aluminum Roof
Coating" at 1 to 2 gal/sq.
25. Deck: C-15/32 Incline: 1/4
Insulation: Two layers glass fiber (staggered joints),1 in. each.
Base Sheet: Type G2, mechanically fastened or adhered with hot
roofing asphalt.
Membrane: "Ruberoid Torch Granule 1" (modified bitumen):
Surfacing. Karnak Chemical "Karnak No. 97 Fibrated Aluminum
Asphalt Roof Coating" at 1 to 2 gal/sq.
26. Deck: NC Incline: 1/4
Membrane: - 'fRuberoid Torch Granule 1" (modified bitumen).
Surfacing. Karnak Cheith:al—"Karnak No. 97 Fibrated Aluminum
Asphalt Roof Coating" at 1 to 2 gal/sq.
27. Deck: NC Incline: 1/2
Insulation (Optional): Perlite, wood fiber or glass fiber, 1 in. max,
mechanically fastened or adhered with hot roofing asphalt.
Base Sheet:. Type G2 or "Flex Base 60" (modified bitumen), mechani-
cally fastened or adhered with hot roofing asphalt.
Membrane. "Ruberoid Torch Granule 1", heat fused.
Surfacing-. Monsey Products "Endure Aluminum Roof Coating",
"Weather Check" or "Pro -Grade Aluminum Roof Coating", 1.5 gal/sq.
28. Deck: NC •Incline: 1/2
lnsulation (Optional): Perhte,-wood fiber, glass fiberor isocyanurate/
� r aiiethape board,.2 in. max, mechanically fastened.
Base Sheet: Type G2(modified bitumen), mechanically fastened or
adhered with hot roofing asphalt.
Membrane: "Ruberoid Torch Granule. l" (modified bitumen), heat
fused.
LOOK'FOR THEUL'MARK ON PRODUCT
I
_V
C17r
HIGH VELOCITY HURRICA �SJiIW =ERS NOTIFICA N FOR ROOFING
R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section
R4402 govern the minimum requirements and standards of the industry for roofing system installations.
Additionally, the following items should be addressed as part of the agreement between the owner ant the
contractor. The owner's initial in the designated space indicates that the item has been explained.
1. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of
providing that the roof system meets the wind resistance and water instruction performance standards.
Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues
such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of
the agreement between the owner and the contractor.
2. ft 6Qenalling wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior
to removing the existing roof system).
3. _C�Common roofs: Common roofs are those which have no visible delineation between neighboring
units (i.e., townhouses, condominiums, etc.) In'buildings with common roofs, the roofing contractor and/or
owner should notify the occupants of adjacent units of roofing to be performed.
4. C 13 CA Exposed Cetling: Exposed, open beam ceilings are where the underside of the roof decking can
be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail
penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the
appearance.
5. Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural
distress and may require the review of a professional structural engineer. Pounding may shorten the life
expectancy and performance of the new roofing system. Pounding conditions may not be evident until the
original roofing system is removed. Pounding conditions should be corrected.
6. 01.1301 Overflow scuppers (wall outlets): It is required that rainwater flour; off so that the roof is not
overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in
accordance with the requirements of Sections R4402, R4403 and R4413.
7. Ventilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. It may be beneficial to consider additional venting which can result in extending the service life of -the
roof.
" 3,
Owner/Agents Signature Date Contraof Signature Date
Revised on 7/9/2009 LD