Loading...
RF-14-2176Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-223711 Permit Number: RF -10-14-2176 Inspection Date: December 08, 2014 Permit Type: Roof Inspector: Rodriguez, Jorge Inspection Type: Final Roof Owner: OLIVA, TERESA Work Classification: Repair Roof Job Address: 301 GRAND CONCOURSE Miami Shores, FL 33138 - Project: <NONE> Contractor: T&S ROOFING SYSTEMS INC. Buildina Deoartment Comments Phone Number (305)807-1210 Parcel Number 1132060133850 Phone: 3051265-2654 TILE ROOF REPAIR Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-222889. CREATED AS REINSPECTION FOR INSP-220971. Product used not as aproved. Missing uplift test. Failed ❑ Product on open valley must be either cut or coated Roof OK Missing revision Correction Needed ❑ Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. For Inspections please call: (305)762-4949 December 08, 2014 Page 1 of 1 Miami Shores Village "1CFN "'P Building Department DEC 01,2014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY. Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 BUILDING Master Permit No. PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ROOFING ��EVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [—]MECHANICAL ❑PUBLIC WORKS []CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 6 Y67�V\'� A (c ws- e City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder) �� I�L� Phone#: Address: Q 1 (� 4 C r, VA rcV'✓ City: >� i q V'i'1 t c State: Zip: Tenant/ essee Name: Phone#: Email: CONTRACTOR: Corppany Name: 1 c Address: R City: 1 Qualifier Name: State Certification or Registration #: C7 Zip: Phone#: z— Certificate of Competency M DESIGNER: Architect/Engineer: Phone#: Address: City: State Value of Work for this Permit: $ Type of Work: ❑ Addition ❑ Alteration Description of Work: T6 Specify color of color thru tile: Square/Linear Footage of Work: ❑ A),ew ❑ Repair/Replace Zip: ❑ Demolition Submittal Fee $ Permit Fee $ ` CCF $ CO/CC $ Scanning Fee $ a Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (ReAsed02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with 'an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature. - OWNER or AGENT The foregoing instrumen was/acknowledged before me this day of C . 20 . by U 5GlIVq . who is personally known to me or who has produced as identification and who did take an oath. NOT, Signature CONTRACTOR The fo egoing instrument was acknowledged before me this day of 20 by l e�-M-AnLowho is personally known to me or who has produ ed as identification and who did take an oath. Structural Review Clerk (Revised02/24/2014) % I Sign• Sign i Print: Print'c` Seal Seale" hdo9ary P blic State of Flora oAP" Ns a Notary Public State a FI 'da � � a I'-{riitrl e,0z ` u• �.' _,. i';aniel Perez fJiy Commission `-aT ; 'lly Commission EE123821 Expires � EE1 6 ba o� 08/21/2015 o, ,C Expires 08/21/2015 APPROVED BY Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Roof System Manufacturer: V U Product Approval Number: Minimum Design Wind Pressures, If Appil ble (From RAS 127 or Calcu Oo4): P1: � I, P2• ` a Maximum Design Pressure Product " � Approval Specific System: r Method of Tile Attachment: "l Roof Slope: 12 SteeR Sloped System Descri tion Deck Type: Type L I 12F /q- M IAW ® MIAMI -DARE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.niianddadegov/pera Eagle Roofing Products, LLC. 1575 E. C R 470 Sumterville, FL. 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Eagle Seal Underlayment LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. VERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 11-1011.05 and consists of pages 1 through 4. The submitted documentation was reviewed by Alex Tigera. MIAMI -DADS COUNTY ...t NOA No.: 12-0507.03 Expiration Date: 03/03/15 Approval Date: 09/05/13 Page 1 of 4 ROOFING COMPONENT APPROVAL Category Sub -Category Material: Roofing Underlayment SBS TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Eagle Seal 3' x 33.4' rolls TAS 103 Self -adhering, non -woven fiberglass mat 3' x 66.8' rolls reinforced membrane for use as an 3' x 72' rolls underlayment in high temperature sloped roof assemblies. MANUFACTURING PLANT(S): 1. Tuscaloosa, AL EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials Technologies BWR-514-02-01 (rev) ASTM D 1970 09/04/09 VRMI-011-02-01 ASTM D 1970 03/30/09 BWR-511-02-01 ASTM D 1970 09/29/09 BWR-5.11-02-01 ASTM D 4798 .09/29/09 BWR-522-02-01 ASTM D 1970 03/16/10 BWR-513-02-01 TAS 103 02/19/10 BWR-518-02-01 TAS 103 02/19/10 BWR-533-02-01 TAS 103 09/07/12 BWR-534-02-01 ASTM D 1970 09/07/12 MIAMI -nape COUNTY NOA No.: 12-0507.03 Expiration Date: 03/03/15 Approval Date: 09/05/13 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 19/32' or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. * In the Non-HVHZ area a Base Sheet is optional. Membrane: One or more plies of Eagle Seal underlayment with a minimum 3" side lap and 6" end lap. Surfacing: Approved Roof Assemblies. See Limitation 43. MIAM4DADE Cc)uNWM NOA No.: 12.0507.03 �E,122,573411Expiration Date: 03/03/15 Approval Date: 09/05/13 Page 3 of 4 I LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. Eagle Seal underlayment shall be installed in strict compliance with applicable Building Code. 3. Eagle Seal underlayment may be used in asphaltic shingles, metal panels, wood shakes and shingles, quarry slate, and tile roof assemblies (mortar, adhesive, and mechanically set). 4. Eagle Seal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. Eagle Seal underlayment shall not be left exposed as a temporary roof for longer than 90 days of application. 6. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 7. Eagle Seal underlayment may be used with any approved roof covering Notice of Acceptance listing Eagle Seal underlayment as a component part of an assembly in the Notice of Acceptance. If Eagle Seal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami - Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 8. Eagle Seal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 12. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Eagle Seal underlayment shall be applied over the underlayment. 13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. MIAMMADE COUNTY END OF THIS ACCEPTANCE MIAMI•DApBCoUNW NOA No.: 12-0507.03 ' Expiration Date: 03/03/15 Approval Date: 09/05/13 Page 4 of 4 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 796CEIJVEZ T9�4214 i FBC 20 l -C> Master Permit No. 1 `Z1 -7 (e:11 Sub Permit No. ❑BUILDING ❑ELECTRIC ROOFING ❑ REVISION ❑ EXTENSION [j RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: A &J NC6, kj 1 r? -e Folio/Parcel#: 1 I - JLV6 +C 13- -3S56 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): `jw�o 6�� V� . Phone#: �� O 3 Address: '361 6fo d a A1C oU,,�- City: State: Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: T+ -c, jd Phone#: " Z6 Address: ' � \� ° 2, -� e-31 L City: a State: Zip: Qualifier Name: 61,6- Phone#: State Certification or Registration #: Off, 3 -11f 7 Z Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State:} Zip: Value of Work for this Permit: $ Square/Linear Footage of Work:X t Type of Work: ❑ Addi�io1 n ❑(Altercation ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: ie 1061 Iy- Specify color of color thru tile: Submittal Fee $� Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Notary $ Technology Fee $ Training/Education Fee $ Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ (Revised02/24/2014) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signatur� OWNER or AGENT The foregoing instrument was acknowledged beforT this day of 20 by 1 �l who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Pri A°� Notary Public State Seal: Daniel Perez QBr°�Q@o xPC sm08/21/20�5 Signature_ s CONTRACTOR The foregoing instrum wa I acknowledged before a this day of f✓ 20 by U �'5 10� who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign Seal °11"Y N., Notary Publi tate Daniel Pe zj I ca My Commissi EE1 Uf F�®0` Expires 08/21/2015 ########################################################################################################### APPROVED BY `d Plans Examiner Zoning Structural Review Clerk (Revised02/24/2014) Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section D (Steep Sloped Roof System) Roof System Manufacturer: s Product Approval Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): 131:—Y P2: L 6- P3: Maximum Design Pressure Product Approval Specific System: Method of Tile Attachment: V�jj� j Ve Lclq C nAI I' I I it �- Steep Sloped System Description Deck Type: Roof Slope: Type L 12 1 Ridge Ventilation? Mean Roof Height: Baffler: LOG 0000•• Fastener Type & Spacing. q� �i r, •. 1� �-S ��il..�: � •' ` 0000.. 0000.. Adhesive Type: 7 • �. 0000 0000. 1C .. .. 0000 0000. ... .= . 0000.. Type Cap Sheet:EN .. • 0000.. Covering: Type 0000. Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section E (Tile Calculations) For Moment based tide systems, choose either Method 1 or 2. Compare the values for M, with the values from Mt. If the Mr values are greater than or equal to the M, values, for each area of the roof, then the tile attachment method Is acceptable. Method 1 "Moment Based Tile Calculations Per RAS 127" (P,: x Ag ?,q I = 13 Me: (P2: x a , 5 = M„ � Product Approval Mi X) _ - M8: = Mr2T5, Product Approval Mt (P3: x Ma: = Mi3 Z r 5 Product Approval mf� Method 2 "Simplified Tile Calculation Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval Mf M Required Moment Resistance* Mean Roof Height --lo- -►Roof Slope Roof 15' 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 1 27.1 28.2 1 30.0 *Must be used In conjunction with a list of moment based the systems endorsed by the Broward County Board of Rules and Appeals. For Uplift based tile systems use Method 3. Compare the values for IF with the values for Fr. If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method Is acceptable. Where to Obtain Information • Description 0000.. 0 0 Method 3 "Uplift Based Tile Calculations Per RAS 127" '.. • , • (P,: x 1: _ x w:= _ ) - W: x cos 0: - = Fr, Product AppYptkyp; ..00 (P2: x 1: = x w:= ) - W: x cos 0: - = F12 Product Appee4a . (P3: x 1: = x w:= - W: x cos 0: - = F,3 Product ApplOMIF, 9 0 • • Roof Slope � 0000 .... .0. 0000.. 0000.• • • 0...00 .000. . 0000. .000.. . 0000.. . • 0000.. . . Where to Obtain Information • Description Symbol Where to find 0000.. Design Pressure Pt or P2 or P3 RAS 127 Table 1 or by an engineering analysis prepared by PE based on ASC 7 Mean Roof Height H Job Site • • • Roof Slope B Job Site Aerodynamic Multiplier A Product Approval Restoring Moment due to Gravity Ma Product Approval Attachment Resistance MI Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F. Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W PMuct Approval Tile Dimensions I = length w - width Product Approval AD calculations must be submitted to the Building Official at the time of permit application. .0. 0000.. 0000.• • • 0...00 .000. . 0000. .000.. . 0000.. . • 0000.. . . MIAMMM ® MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. • TERMINATION of this NOA will occur after the expiration date or if there has been a revisd®n ar change iii the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endoraeTeAt of anyTmauct, • • • • • for sales, advertising or any other purposes shall automatically terminate this NOA. Failure fV(! Ply with aAy sectio$....; of this NOA shall be cause for termination and removal of NOA. 0"" ' •.•• •..• •s..• ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County,:l±�orida, * • f`llow •� • • 4 ��.... by the expiration date may be displayed in advertising literature. If any portion of the-NC6A is displayed, then it shall be done in its entirety. *be*:* INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and • ' shall be available for inspection at the job site at the request of the Building Official. 0000 This revises NOA#12-1219.01 and consists of pages 1 through 4. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 13-1113.05 Expiration Date: 07/31/17 _ Approval Date: 03/13/14 Page 1 of 4 0 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: SBS PRODUCTS DESCRIPTION: Product BORAL TileSeal Dimensions 36" x 36' rolls 36" x 72' rolls MANUFACTURING LOCATION: 1. Brentwood, NH EVIDENCE SUBMITTED: Test Agency Underwriters Laboratories, Inc. IRT-Arcon, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Construction Materials Technologies, LLC. Test Product Specification Description TAS 103 SBS self -adhering asphalt sheet material with a ASTM D 1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in sloped roof assemblies. Test Identifier Test Name/Report Date R14610 Follow up Service 03/28/02 02-012 TAS 103 02/28/02 NEI -006-02-01 TAS 103 04/01/02 NEI -008-02-01 TAS 114 (II) 07/30/02 NEI -045-02-01 ASTM D 4798 & ASTM G 155 08/08/07 NEI -053-02-01 ASTM D 4798 & ASTM G 155 05/01/08 NEI -076-02-01 TAS 103 / ASTM D4798 02/14/11 NEI -034-02-02 ASTM D 1970 01/29/13 • • • •• • 0000 •••••• •••• • 686.00 0 00.6 0000 • • 0000 • • 0000 e•••6• 0000 •• of •• • •60.0• • • • • • ••0.6• •• • •••• • 0000•• 0000•• • 0000• 0000• 0000•• • • • 0000•• 0000•• • s NOA Nb.: M2. Expiration.pate: 071YV Approval'Date: a3)1S/'14 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and two staggered rows 12" o.c. the field of the roll. Membrane: One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to deck with approved annular ring shank nails and tin caps at a maximum 6" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Approved Adhesive Set Roof Tile Systems, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. •0.00• NOA No.: 13-1113;t1Si: . Eapiration.Date: 07/31/17,' Approval Date: 03/13/14 Page 3 of 4 .. . .... 0 0.0.00 •... ...... 0000•• • • • 0000•• 0000 0000 • • • • • 0 0000 •••• 00.00 • 0000•• 0000 0000• •• •• •• • 0000•• • •••••• • • • • • • 0000•• •••••• • • • • • • • • 0000•• •• • 0000 0 • NOA No.: 13-1113;t1Si: . Eapiration.Date: 07/31/17,' Approval Date: 03/13/14 Page 3 of 4 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly to the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6:12". 9. BORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 0000.. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This Zrgef0ece shall be pressed • •; • in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSe"Uagrlayment '. 000.08 sees Osseo* shall be applied over the underlayment, and sealed using an SBS modified mastic. • • * 0 8 e 0 0 • 15. All products listed herein shall have a quality assurance audit in accordance with the Rle#ids BuildivJ ode ar:d'**: Rule 61 G20-3 of the Florida Administrative Code. 00000 •••• 00000 s 0 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufaoWeer's nage lego, cry and state of manufacturing facility, and the following statement: "Miami -Dade CountyrgQ jjjt Control Approved or the Miami -Dade County Product Control Seal as shown below . . e . 0000.. 0000.. MIAMbQADE CC3UNTf • •• :0000: 0 00 00 END OF THIS ACCEPTANCE NOA No.: 13-1113:05 Expiration Date: 07/31/17 Approval Date: 03/13/14 Page 4 of 4 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida. 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.goy/economy 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or: eha;ge in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an end(6gft4t of any."oduct, for• .* • sales, advertising or any other purposes shall automatically terminate this NOA. Failure to "&uplF with7443iStction of..;. this NOA shall be cause for termination and removal of NOA. ...:.. 0000.. 0000 0080 e 0 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, FICA t, and foHeid by the:*-. expiration date maybe displayed in advertising literature. If any portion of the NOA is disp%M; then Vs"l Lbe doMl • • .. .. 0000.. in its entirety. 00 • . 0000.. . . INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its $s&*;&ors a*pd•00 0. shall be available for inspection at the job site at the request of the Building Official.0000 :9000: .. •.i• This NOA revises NOA 13-0502.02 and consists of pages 1 through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0805.01 Expiration Date: 05/10/17 4.000W Approval Date: 09/04/14 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using 2 -Component Foam Roof Tile Adhesive AH -160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Descrintion Specifications 3MTM 2 -Component N/A Foam Roof Tile Adhesive AH -160 Foam Dispenser N/A RTF1000 ProPack® 30 & 100 N/A TAS 101 Two component polyurethane foam adhesive PRODUCTS MANUFACTURED BY OTHERS: Dispensing Equipment Dispensing Equipment Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: 1. Tomball, TX. PHYSICAL PROPERTIES: Property Density Compressive Strength Tensile Strength Water Absorption Moisture Vapor Transmission Dimensional Stability Closed Cell Content ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 2 of 11 0000.. 0000.. Test Results • • • • • • •. V09.00 •••• 000000 ASTM D 1622 1.6lbs ./ft.3 000000 ASTM D 1621 18 PSI Parallel to rise • • • • • • • • : • • • •: 12 PSI Perpendicular to rise • • • • • • • • • • • • • ASTM D 1623 28 PSI Parallel to rise ";": '•"' ASTM D 2127 0.08 Lbs./Fe .";'. ASTM E 96 3.1 Perm / Inch • • • • • • ASTM D 2126 +0.07% Volume Change @ ;40° 1 2 weik3 • •, +6.0% Volume Change @ 13TJ* C00% Hiw1Wty9 2 • ; weeks 000 00 o:000 ASTM D 2856 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Reno Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: ' 00 0' 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly 1 r'fire rat.0000 00 00' • ..... 2. 3M "m 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, logy! Sa kjgh tile ppodles. . 3. Minimum underlayment shall be in compliance with the Roofing Application Standard );0. • 4. Roof Tile manufactures acquiring acceptance for the use of 3M'" 2 -Component Foam Reof+I+ile Adliesive XH. ...... 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. ; • •; •; • •, 5. All products listed herein shall have a quality assurance audit in . ...... accordance with the I lori(t. Buil4dg 6tde and • Rule 61 G20-3 of the Florida Administrative Code. '..' .... :0000: 00*0 NOA No.: 14-0805.01 an�rn,4aos ccwMir Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 3 of 11 INSTALLATION: 1. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160. 2. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B)• 6. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF 1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. •00••• NOA No.: 14-0805.01 {APPROVED Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 4 of 11 •••••• •• • 0000 • 0000•• 0000 0000•• • 0000•• • • • 0000•• 0000 0000 • • 0000 0000 0000• • 0000•• 0000 000• 0• •• •• •• • •••••• • 0000•• • • • • • • 0000•• 0000•• • • • 00990• •• • 0000 • • NOA No.: 14-0805.01 {APPROVED Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles 41 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. APPRgYED BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. • .• • .... 0.9.60 0..•. 0000 0000 0000•• 0000•• • • • 0000 0000 0000 as • • • • 4660•• •6•• • • 0••• 0000• 0000•• • • • 0000•• 0000•• NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 5 of 11 . ADHESIVE PLACEMENT DETAIL # 1 Sos�am,. aiPoft h"*l 1� hhW BaumoODUM APPROV�DI Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. High Profile / Single Pan e :000:0 g gsees.. ss 0 sees . 1. Starting at the eave cour"o.apply a nf"i wA 2" . e e.: e (50.8 mm) x 10" (254 mm) �*W' (25.4 min) foam sees.. paddy onto the underlayjrl ositioLied M show; • under the pan portion of &i2•t21e closest' the • • e • • ... .. ..0. 00000 overlock of the tile beim se . e e e • e0 se • 0000.0 2. Continue in same mannCr. Ins1re ap,4roxigiately L7...:. (109.7 cm2) — 23 (148.4, CM2).,square:AM 18hesive contact with the undersi&& tte tile. sees : *so*: s•e: sees NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 lEhpdt�i(srtettb d1i�,'�ei 9 71% It lV�t6rouyhiceint tom: y BOOMS to* on We Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) - 12 (77.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a mmimum.2" (50.8mm) x 7" (177.8 mm) x 1" (25.1 mrpj loam pa11y onto tl" • • • • underlayment positioned as thoWh and *an •, portion of the tile closest t8 IN b8erlock'UTMe tile 00000* •es • being set. :....: .... .... • . . see*• • • 3. Continue in same manner. Jgsw;.approxjWrely 12" •; . • • (77.4 cm2) - 14 (90.3 cm),%qW inch Wsit'e ...... contact with the undersideckks-tile. .• . . . . ...... (Instructions continued on ne" page) "" ' NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) APPROVED High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan dome portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. ...... ...... ...... ..... •• ••• • • • ••••• •••••• •••••• • • •••••• •••••• • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 M f t1 • P�ddyQuodee't� 4 Y � 2sth1. ° to � IecaOa Rath ow Pr eMe W*MU0Vtnftrcu fie When mem ftm$i taaftsugl a fiW*. //�e i044 EMChmn am 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 int (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) • : ° 64. 00.000 0 0 • ° 0000 ° 000000 ° 0::::o 0000 000000 • • • ° • 0 0000 0 0 000000 000000 • • ° • • 0 0 0 0 000000 000000 ° • ° ° 00 0 • 0000 000000 00 ° • NOA No.: 14-0805.01 Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Bence" WNW q!4 m�an � 4s4im 2:4 as ,y6 Een�e [aa�u 14iQ,x�7. r �i�i �t•'T''"'ri�1�4T 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/a" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71cm) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. • •• • 0000•• 0000 • • 000:0• • 0000• • •0000• •6••66 • • ••0000 0000 6.60•: 0000 • • • • •0.6 0060•• 000.0 • • 0000 • • :0066•0 0060:• • 6 • • • 006.00 0000:0 • 60 • •�•• ••••6i ••• NOA No.: 14-0805.01 Expiration Date: 05/1.0/17 Approval Date: 09/04/144 Page 10 of 11 1) place enough adhesive toachieve 65 to 701 In contactwiththepantue. 2)'Iurn covers upside dvam.Place adheatve In to 1 in. from outwe edge of cover tile. Then Gnstalithe tile. Ender, 30 to 2Sa13n.mntact area: Underuplent Eave dosurd (motard www) Fascia ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL Steep pitch applications (when required) Remove top porter of the save course cover tile.Abutto second course of pan Wes. Ensure eave end Open end cover tiles am flush at eave line. Two Piece Barrel - High ProflleTlle Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm.) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, :Z' jS .8 mm) x 4" (101.6 mm) n2tiiSm or the tre wire ...... system using galvanized, sWpless stael,*U. .' copper wire and compatibl"ls maybe used. • • • • • •... . • 0000 0000.: 0000 • • 0000 • • 0000.. 0000. . 0 .0.. END OF THIS ACCEPTANCE • • '.0' 0 • 0 0 a 0 0:0 0 . • 0 . a . 0 .00000 0 000000 .0 0 0060 • 0 00..0. NOA No.: 14-0805.01 aflaMu'nffFaIN, Expiration Date: 05/10/17 Approval Date: 09/04/14 Page 11 of 11 MIAMI -DARE COUNTY M1AMa�►DE " PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economy Sulacer USA, Inc. 6801 NW 77 Avenue, Suite #302 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material falls to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Altusa G°S" Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of a$ygioduct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to tolxfplp withan4 section ' • s of this NOA shall be cause for termination and removal of NOA. 00000, • 0 0.0 . • 0 ego:** 0000.. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, F1or4ftosqd follow.4.by they....; expiration date may be displayed in advertising literature. If any portion of the NOA is displaye$, then it s" be done..... • in its entirety. • . . "� • •. �.. • .00000 00000. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufactilrer'or its di stribtttors and . • shall be available for inspection at the job site at the request of the Building Official. see • • • • : • **00:0 .. 0 0000 ....: This renews and revises NOA No. 12-1203.07 consists of pages 1 through 7. • The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 14-0605.03 MIAMI`DQD6COUWT1l Expiration Date: 08/26/19 o � Approval Date: 08/28/14 Page 1 of 7 i ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Clay Deck Type: Wood 1. SCOPE This approves a roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.V. and distributed by Sulacer USA, Inc., as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant DiiSpecifications Specifications Description Altusa "S" Clay Roof Tile Length: 18.75" ASTM C 1167 High profile, one-piece, `S' shaped single roll clay Width: 10.75" tile with a nominal 2-'/2 inch headlap. For direct Thickness: 0.46" deck nail -on, mortar set, or adhesive set Height: 3.6" applications. Trim Pieces Length: varies TAS 112 Accessory trim, clay roof pieces for use at hips, Width: varies rakes, ridges and valley terminations. varying thickness Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Pimienta Cortes, Honduras 2.2. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date American Test Lab of South RT0426.01-11 ASTM C 1167 01"444 Florida • • .. • • American Test Lab of South RT0706.01-11 Static Uplift Testing ...:.. Oi/ii1'l l •••... Florida TAS 101 •... • American Test Lab of South 2397-116 ASTM C 1167 06#"67 ... • Florida • • • • • �•••�• .••;•• ..;•�• American Test Lab of South RT0712.02-13 ASTMC 1167 :'•;•; 07/19/13 ••on:' Florida 0��•0 �: •07/29/14 �•�•�� American Test Lab of South RT0714.02-14 ASTM C 1167 •.' ; • • Florida 0 066• 08*0 American Test Lab of South RT0808.01-14 Aerodynamic Multiplier 08/13/14 Florida Restoring Moment Calculations NOA No.: 14-0605.03 Expiration Date: 08/26/19- Approval 8/26/19Approval Date: 08/28/14 Page 2 of 7 Ll The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. TAS 101 (Adhesive Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 25-7200-1 Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 (Quick -Drive Screws, Battens) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC -78 TAS 100 Celotex Corporation Testing MTS 520649 TAS 102(A) May 2000 PRI Asphalt Technology, Inc. CLF -003-02-01 TAS 102 October 2001 Redland Technologies 7161-03; Appendix III TAS 102 Dec. 1991 Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering, Inc. Evaluation Calculations 25-7183 March 1995 Walker Engineering, Inc. Evaluation Calculations 25-7094 February 1996 Walker Engineering, Inc. Evaluation Calculations 25-7496 April 1996 Walker Engineering, Inc. Evaluation Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 . ••.• 8888:. : ....69 8888 869.0. 8888.. 0....' •0 8888.. 8888 .... ' 8888 .. • 8888 8888.. 8888 ..... :09.9. • 8888.. 99 . 8888 :0004 NOA No.: 14-06.05.03 . Expiration Date: 08/26/19. Approval Date: 08/28/14 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be -in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 3.8 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Altusa `S' Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (lbf) Length-1(ft) Width -w (ft) Altusa "S° Clay Roof Tile 6.5 1.56 0.9 Table 2: Aerod namic Multipliers -(ft) Tile Profile X (ft3) Batten Application 3 Direc eck Appl c tion Altusa "S" Clay Roof Tile 0.269 0.291 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) ••:" ••••• 2 . 12 3": 12 4": 12 5 . 12 6": 12"::6908 9 rQ�r Batten Direct Batten DWit Batten Direct Batten Direct Batten Direct' Batt• *Direct,, Deck 'Deck Deck Deck • • k 0 • • deck. 4.70 4.71 4.63 4.65 j 4.54 4.57 4.43 4.46 4.30 4.34 4.16 4.21 NOA No.: 14-0605.03 Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile Altusa "S" Clay Roof (Min 15/32" plywood) (Min. 19/32" plywood) Tile Altusa "S" 2-10d Ring Shank Nails 28.6 41.2 19.4 Clay Roof Tile 1-10d Smooth or Screw 5.1 6.8 2.8 Shank Nail 2-10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1 .#8 Screw 28.7 28.7 18.1 2 .#8 Screws 58.2 58.2 26.8 1-10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1-10d Smooth or Screw 29.3 29.3 24.0 Shank Nail Eave Clip) 2-10d Smooth or Screw 27.6 27.6 38.6 Shank Nails Field Clip) 2-10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile ..... 4 -WOO • Resistance Altusa "S" Clay Roof ff3;Mw 2 -Component Foam Roof Tile Adhesive AH -160 3 Tile Adhesive 29.3 2 See manufacturer's component approval for installation requirements. 3 Fle)able Products Company TileBond Average weight per patty 10.7 grams. 3M- 2 -Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf 7ft4bA : for Single Patty Adhesive Set Systems •••••• '....' Tile Profile Tile Application MinllllLIM Attachment , •�� esistaaCl2•• Altusa "S" Clay Roof Tile 3M' 2 -Component Foam Roof Tile Adhesive AH -160 ..... 4 -WOO • 3M'• 2 -Component Foam Roof Tile Adhesive AH -160 •• 38.7 �.. • • ff3;Mw 2 -Component Foam Roof Tile Adhesive AH -160 O:*a2.05 6 • 4 Large paddy placement of 63 grams of 3M- 2 -Component Foam Roof Tile Adhesive AH -160 , •...:. • • 5 Medium paddy placement of 24 grams of 3M'' 2 -Component Foam Roof Tile Adhesive AH -160 • • ,:. 6 Large paddy placement of 70 grams of 31VI'" 2 -Component Foam Roof Tile Adhesive AH -160 • • • • NOA No.: 14-0605.03 Mu►MI'DAD6� Expiration Date: 08/26/19 APPROVED Approval Date: 08/28/14 Page 5 of 7 0 I Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Altusa "S" Clay Roof Tile Mortar Set 24.50 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". ALTUSA MADE IN HONDURAS LABEL FOR ALTUSA "S" CLAY ROOF TILE. (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 14-0605.03 ��; �,�� Expiration Date: 08/26/19 Approval Date: 08/28/14 Page 6 of 7 r 0 PROFILE DRAWING iC . • • 6060 660660 •�•.. 6666.. .. • 00 . 6666' 6666.. 6666.. 66..• 6666 �..... 6666 '6666' 6666.. 6666. . 6666 • 6666' •�•.. •6666 ALTUSA `S' CLAY ROOF TILE : "; •; . • . 6 :666:6 6666:. END OF THIS ACCEPTANCE "" • NOA No.: 14-0605.03 Expiration Date: 08/26./19 Approval Date: 08/28/14 Page 7 of 7