Loading...
WS-14-710CESAR M. CAVO A.I.A. a r c h i t e c t 4906 Campo Sano Ct. L Coral Gables, FL 33146 Phone (305) 740 7929 IL Fax (305) 740 7929 Letter Monday, April 14, 2014 To: Village of Miami Shores Building Department 10050 N.E. 2 Ave Miami Shores, FL 33138 Re: 640 N E 98 St Miami Shores, FL 33138 Dear Sir. I approve the use of 2x4 p.t. wood bucks fastened to masonry wall, concrete beam and window sill with 1/4"X 3'/4" tapcons as indicate on plans. Wood shims shall be used at any gaps between the window and the wood buck. Should you have any questions, or need additional information, please do not hesitate to contact me. Sincerely Cesar M. Cano Cesar M. Ca no A.I.A. State of Florida Registration # 4929 Page 1 of 1 September 8, 2014 To: Miami Shores Village Building Department 10050 NE 2'd Avenue Miami Shores, FL 33138 Fra/ Lwsp. 9/1o/ly Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net Roof Tile Uplift Test Report Test Date: September 8, 2014 Permit #: RF -7-13-1635 Address: FGCC PROPERTY INVESTMENT INC. 38 NW 109th Avenue, Miami Shores, FL Contractor. I & M Roofing Roof Pitch: 3:12 Attachment method: 3M Adhesive Polyfbam Ah -160 Tile Type: Boral Vanguard Roll Roof Tile Device Used: "11VIADA DPS 110" force gauge Serial # 155879E) Total Sloped Roof Area: 1.77 squares All Testing is in strict accordance with the Florida Building Code, 2010 Edition, High Velocity Hurricane Zone — Testing Application Standard (TAS) 106. Roof Area: 1.77 squares Total Number of Tests Number of tests Passed % Passed Field Area (1): Perimeter Area (2): (Tl -T8) 8 8 100% No. of Corner Areas (3): 2 2 100% Ridge/Hi Areas:6 pcs T9-T10 Based upon the field tests, I certify that 100% of the static up -lift tests "PASSED" the testing criteria of 35.0 lbf load, and meets the attachment resistance for adhesive Set Systems, as specified in the NOA. Should you have any questions regarding the above, or if require additional information, please do not hesitate to contact this office. Sincerely, CeBB Engineering & Testing Co. (NOA 13-01h 9IC.a 0 revises NOA 08-0924.12) 09/08 Eduaru, 'P. IE. Fla. Reg. No: 59997 For The Firm Cc: I & M Roofing Enc. Location Sketch Calibration Certificate Engineering & Testing Co. 7450 GnfFn Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax. (954)581-2415 www.cebb.net HANDLIFT RESULTS: Passed the protocol criteria of less than 3% loose. We performed the up -lift test. Roof Area: 1.77 squares Total Number of Tests Number of tests Passed % Passed Field Area (1): Perimeter Area (2): (T1 -T8) 8 8 100% No. of Corner Areas (3): 2 2 100% Ridge/Hip Areas: 6 pcs (T9-T10) TAS 106 TESTS LOCATION SKETCH Permit # RF -7-13-1635 FGCC PROPERTY INVESTMENT INC. 38 NW 109th Avenue, Miami Shores, FL Engineering & Testing Co. 7450 Grim Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net TEST RESULTS (P = PASSED, F = FAILED) uplift Upfift Puff Test PuH Test WPM I 1 D Engineering & Testing Co. 7450 Griffin Road, Suite 140, Davie, FL 33314 Phone: (954)581-7115, Fax: (954)581-2415 www.cebb.net OC Metallurgical, Inc. Testing & Consulting Services CE13B Corporation P.O. No. Verbal CALIBRATION CERTIBICATF Imada-Digital Force Gauge Range 0-50 kg. Accuracy f1.5 % @ Full Sole Serial No. 155879 Standard In kg. Instrument Reads in 0 kg. 0 10C 9.9 20 C 19.9 40 C 39.9 60 C 59.9 80 C 80.0 100 C 100.2 10T -9.9 20 T -19.9 40 T -39.3 60 T -59.3 80 T -79.9 100 T -100.3 Scale is within t1.5% at full scale. January 14, 2014 QCM Job No. 14AM 29 Ca anted with I== Towh Mad mo, Lead WL SIN 936, QCM-414, 2 pieces. RanW 0-1000 Lb'a Accuracy at 31.0'1/. N.LS.T. 0 Cert. @RP10042MM. Dam 8/9/2012 -8/9!2013. - C"-atWLAW ANSUNCSL2'340-1 The accuracy and calibration of this instrument are traceable to the National Institute of Standards & Technology and are guaranteed to meet published specifications. Date Calibrated 1114014 Date Due 1/14/1015 Kevin Gyrate Q. C. Metallurgical, Inc. 2870 Stirling Road • Hollywood, Fl. 33020-1199 * (954) 889-0089 ° Fax (954) 362-5742 E-mail: fgmte@gcmet.com