Loading...
RC-12-1570Miami Shores village. Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: JOB ADDRESS: BUILDING FBC 20 Permit No. AC Master Permit No. I 157 0 ROOFING City: Miami Shores U County: Miami Dade Zip: 1 -3 8 Folio/Parcel#: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Address: City: Tenant/I,essee Name: Email,: CONTRACTi' M Co any Name: Address: �, . , _I y (?kj e City: 'Syce5icke State: C. Qualifier Name: Giw1 h ens 4C1 h Phone#: ,State Certification or Regi ation #: 60 S 1 '1 Certificate Competency #• _ Contact Phone# - z1"6 - �'� Email Address: ��� �ih DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ O0/000 Squam/Linear Footage of Work: 0 1� Type of Work: OAddition OAlteration ONew ORep'air/Replace ODemolition Description of Work: Color thru tile: 0 Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW D Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State i. Zip Zip t a Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence ofsch posted nptice, the inspection will not be approved and a reinspection fee will be charged. �) /'I /� The foreg 'ng instrume day o , 20 w is pens ] ow . b NOTARY kBL10 Sign: Print: My C Expires: APPROVED BY \t J-1 IL befor me this a foregoi in ment wa c ledged before methi y of 20 by has produc' 's gon ly ow me or who has producI and who did take an oath. _ tification and who did take an oath. wh Plans Examiner Zoning Structural Review (Revised 3/12/2012)(Revised 07/10/07)(Revised W10/2009)(Revised 3/15/09) Clerk et`�os NC�TAR UBLIC: - - ) ate of F\ot�da5 WIL 'C s geP 23.2�� a 12a810ssn. Sign: - Com Nai�on print No Public, - State of Florida • a My Commis __m Comm Expi-es Sep 211, 28% o9 • n Commission # EE 128810 '.°.�� �••A Bonded Through National Notary Assn. Plans Examiner Zoning Structural Review (Revised 3/12/2012)(Revised 07/10/07)(Revised W10/2009)(Revised 3/15/09) Clerk 12-06-2011 JEFF ATWATER STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW * * CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers Compensation law. EFFECTIVE DATE: 12/06/2011 PERSON: GREENSTEIN FEIN: 223967886 BUSINESS NAME AND ADDRESS: GREENSTEIN CONSTRUCTION INC 8224 CARYLE AVENUE SURFSIDE FL 33154 SCOPES OF BUSINESS OR TRADE: 1- Conduct Construction EXPIRATION DATE: 12/05/2013 BENJAMIN IMPORTANT* Pursuant to Chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be exempt.. apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation If, at any time after the filing of the notice or the issuance or the certificate, the person named an the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. QUESTIONS? (850) 413-1609 OWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01-11 PLEASE CUT OUT THE CARD BELOW AND RETAIN FOR FUTURE REFERENCE STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION CONSTRUCTION INDUSTRY CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS COMPENSATION LAW 0 EFFECTIVE 12/08/2011 EXPIRATION DATE: 12/05/2013 PERSON: BENJAMIN GREENSTEIN FEIN: 223967886 - BUSINESS NAME AND ADDRESS: GREENSTEIN CONSTRUCTION INC 9224 CARYLE AVENUE SURFSIDE. FL 33154 SCOPE OF BUSINESS OR TRADE i- Conduct Construction IMPORTANT F Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who O elects exemption from this chapter by filing a certificate of election L under this section may not -recover benefits or compensation under this D chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be H exempt.. apply only within the scope of the business or trade listed on E the notice of election to be exempt R E Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, -the person maned on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. QUESTIONS? (850) 413-1609 CUT HERE f Carry bottom portion on the job, keep upper portion for your records. DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01-11 r a FIRST-CLASS 'f U.S. PPO�SDTAGE ULUM, FL PERMIT NO. 231 THIS IS NOT A BILL— DO NOT PAY RENEWAL 634299'7 613000-9 AA qq RECFJPTNO• Bw02R� � L CO�I�ISTRUCTION INC STA7EB CGC1514465 33154 SURFSIDEAVE OvflgENSTEIN CONSTRUCTION INC WORKER/S n;r g&M BUILDING CONTRACTOR PyApynADE�COuNT4 TAX C01�p08/15/2012 09010146001 000045.00 SEE OTHER SIDE DO NOT FORWARD GREENSTEIN CONSTRUCTION INC BENJA14IN GREENSTEIN PRES 9224 CARLYLE AVE SURFSIDE FL 33154 �ie�{�eaaa�ttrta11aa11►»>>,a�,�i,nati�ai�l�ia���a�J 1 CERTIFICATE OF LIABILITY INSURANCE °"'�05,`'" 3"""' THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: H the certificate holder Is an ADDITIONAL INSURED, the poiicypes) must be endorsed. M SUBROGATION IS WANED, subject to the terms and conditions of the policy, certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder In lieu of such endorsement(s). PRODUCER Insurance Corporate Associates, Inc 5200 SW 8th. Street Suite 110 Coral Gables, FL 33134 Phone (786) 467-8000 Fax (786) 522-0404 W .CT ONE (786) 467-BOOO N. . (786) 522-0404 E-MAIL commercialquotes@Insurancecorp.net INS AFFORDING COVERAGE NAIC 0 INSURER A : Granada Insurance Company INSURED Greenstein Construction, Inc. 9224 Carlyle Avenue Surfside, FL 33154 (786) 256-9405 INSURER 8 : INSURER C:, INSURER D : INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTRR TYPE OF INSURANCE ADDL UB POLICY NUMBER POLICY EFF POLICDY EXP MYYYI LIMITS A GENERAL LIABILITY © COMMERCIAL GENERAL LIABILITY ❑ ❑ CLAIMS -MADE Q OCCUR ❑ G185FL00041255 12/05/2012 12/05!2013 EACH OCCURRENCE $ 1,000,000.00 DAMAGE TO RENTED PREMISES (Ea occurrence) $ 100,000.00 MED EXP (Any am Person) $ 5,000.00 PERSONAL &ADV INJURY $ 1,000,000.00 ❑ GENERAL AGGREGATE $ 2,000,000.00 GEN'L AGGREGATE LIMIT APPLIES PER: ❑ POLICY ❑ PRO- ❑LOC PRODUCTS - COMPIOP AGG $ $ AUTOMOBILE LUUMMant ❑ ANY AUTO ❑ ALL AUTOS OWNED ❑ AOS SCHEDULED ❑ HIRED AUTOS ❑ AUTOSWNED ❑ ❑Per MBINED INGLE LIMIT a ced BODILY INJURY (Per Imo) $ BODILY INJURY (Per accident) $ PPeOeccident AMAGE $ cid $ ❑ UMBRELLA LIAB ❑ OCCUR ❑ EXCESS LIAR ❑ CLAIMS -MADE EACH OCCURRENCE $ AGGREGATE $ ❑ DED ❑ RETENTION $ WORKERS COMPENSATION AND EMPLOYERS* LIABILnY Y / NTORYUN ANY PROPRIETORIPARTNER/DXECUTiVE OFFICEWMEMBEREXCLUDED?NIA (Mandatory in NH) ❑ If yes describe under DESCRIPTION OF OPERATIONS below ❑ WC SSTAI ❑ OTH- ER EL EACH ACCIDENT $ EL DISEASE - EA EMPLOYE $ E. DISEASE - POLICY LIMIT $ DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101, AddMonal Remarks Schedule, B more space Is required) ALL STANDARS PROVISIONS AND EXCLUSIONS APPLY CERTIFICATE HOLDER CANCELLATION City of Miami Shores Building Department 10050 NE 2nd Avenue Miami Shores, FL 33138 ACORD 25 (2010105) QF SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. ©1988-2010 ACORD CORPORATION. All rights reserved. The ACORD name and logo are registered marks of ACORD STATE OF FLORIDA AC# 6 I L.0 ;-8 1 aim DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CGC1514465 05/25/12 118190934 CERTIFIED GENERAL CONTRACTOR GREENSTEIN, BENJAMIN GREENSTEIN CONSTRUCTION INC IS CERTIFIED under the provisions of Ch.489 Fs Expiration date: AUG 31, 2014 L12052500804 Yy 3nwIAV 31jklHVO VZZ6 N1315NI3"`'i'D NOTICE OF COMMENCEMENT A RECORDED COPY MUST BE POSTED ON THE JOB SITE 9 TIME OFMW WNW= PERMIT No 2 _— IS FOLIO" NO jq5V STATE OF FLORIDA. COUNTY OF MIAMI -RADE: THE UNDIERSIGNEI) hereby gives notice that ImproVernerb will be made to certain real property, and In accordance with Chapter 713, Florida Statutes, the following Information is provided In this Notice of Commencement. 1. LegqLde_,!cqp#oijqf property 2. Description of 3. Owner(s) name.and address: Intergst In property: - tw Name and address of fee simple th 4-0ontractcies name, address and CFN 2013RO431534 OR Bk 28655 Ps 3490? (Ips) RECORDED 05/3112013 09:02S59 HARVEY RUVIN? CLERK OF COURT MIAMI -DACE COUNTY7 FLORIDA LAST PAGE I 4z—_ I %A -u 1 S4 rL." V N if NVA space above reserved for use of recording office a4h ?R> 15-11: LDE8&4 EPS -VT rw ccs33.., - na6 10 f:k 1290 - oqs (6 SMOT_ 5. S,ureW.,(Payment'bqnd required by owner.from contractor, ff any) Name, address and phone number Amount of bond $ 6. Lekjpr's name and address:. 101& 7. Persons within the State* of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.19(1Xa)1., Florida Statutes, Name, address and phone number:_ --&[L* 8. In add in to , himself, Owners designates the following person(s) to receive a copy of the Llenor's Notice as prov Ided In Section 713.13(1)(b), Florida Statutes. Nffft, i4dremps and -Rhone number -Ron Gfelris4pin r5 rel -MI -Pi r% (n rv4W i r -ro'e-u 9. Expiration date of this: Notice of Commencement: (ft 0"On date Is 1 year from the date of recording w9ess a offerent date Is specified) WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATIONOF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS -UNDER CHAPTER 713i PART 1. SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR -.PROPERTY. A NOTICE OF COMMENCEMENT MUST BE AECbRDtb AND 006fM ON THE JOBS RE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSUL, 0 OR RECORDING YOUR NOTICE OF COMMENCEMENT. SlgnaWWs)of YOw2OsSAuthorlz*dOfMflcVer/D)Itertor/8 Own Prepared By -�WlvltPre aced' Print N,!me . . . . . . . . . . The fore ?"Orume ,1=,r po!ledged before me this 44— day Of I [A kX # or Uas for known, or -*U ptoduced the following type of'identlfi+ SIgnature,bi Notelry Public: FrInT Name: (SEAL) VERIFICATION PURSUANT TV SKC"t) 92-5 ORIDA BTATLMW- NOTARY PUBLIC-9TAlt OF FLORIDA Under penalties of Oftify, I deblar'e'that [ have read the foregoing and Frazeei Lopez - that the facts stated In it are true, to the best of my knowledge and belief. Co. # Sion *DD929M Slgnature(sofwr(s) or Owneqs)'s Authorized 011icer/DirOctor/Partner/M'A." Expires SER 29, 2013 anaW. who signed abov BONDED ­iw ATLVNflCH0ND)XGC0..Rqr ByBy 123.01-52 PAW 3 3A0 V NGREENSTEIN CONSTRUCTION License Number CGC 1514465 (786) 256-9405 Greensteincon@aol.com 8/23/2013 Attention: Miami Shores Building Official Miami Shores Building Department Miami Shores, Florida 33138 Greenstein Construction Inc. is withdrawing as General Contractor at 674 Grand Concourse, Miami Shores, Florida 33138 with a master permit of RC -12-1570. The reason for withdrawing is based on non-payment to Greenstein Construction Inc. for general contractor services and has avoided communication since 8/8/2013, even though Greenstein Construction Inc. was updating Carlos & Barbara Miramontes by e-mails after the date of 8/8/2013. Furthermore, Greenstein Construction Inc. has documented the project to this point and has photos and video of what has been completed or altered within Greenstein Construction Inc. direct supervision and what has been completed or altered by sub -contractors not in direct contract under Greenstein Construction Inc. As a general note Carlos & Barbara Miramontes have paid sub -contractors only through 7/29/2013 all other invoices are outstanding for work completed. Benjamin Greenstein Greenstein Construction, Inc. CC: Sent to Carlos & Barbara. Miramontes Certified Mail OFFICE COPY Permit Holder GrewS7'��"� CerinAj Permit # -1 r O 4�v M' F.B.0 Violation Address lo% �T1'l�('ifewic., Date d� /3 By Z ]License Number CGC1514465 (78) 256-9405 Greensteincon@aol.com 8/15/2013 Attention: Viviana Cubillos Administrative Supervisor Miami Shores Building Department 10050 NE 2nd Avenue Miami Shores, Florida 33138 AUG 1 BY:— -------- Greenstein Construction, Inc. would like to put a "hold" onto the project located at 674 Grand Concourse, Miami Shores, Florida 33138 with a Master permit number of RC12-1570. The reason for the hold on the permit is: 1. Because of lack of or no payment to the General Contractor. 2. Lack of understanding on the owners part that the project cannot have items installed into the property without authorization of a Miami Dade product approval, and that any work on the property falls under the General contractor and can cause harm to the Contractor. Benjamin Greenstein Greenstein Construction, Inc. P U �1Z,�Vj _^1 AUG 1 J Lu ►� ��I Y -` - PIGREENSTEIN License Number CGC1514465 (786) 256-9405 Greensteincon(@aol.com 8/15/2013 Attention: Viviana Cubillos Administrative Supervisor Miami Shores Building Department 10050 NE 2"d Avenue Miami Shores, Florida 33138 Greenstein Construction, Inc. would like to put a "hold" onto the project located at 674 Grand Concourse, Miami Shores, Florida 33138 with a Master permit number of RC12-1570. The reason for the hold on the permit is: 1. Because of lack of or no payment to the General Contractor. 2. Lack of understanding on the owners part that the project cannot have items installed into the property without authorization of a Miami Dade product approval, and that any work on the property falls under the General contractor and can cause harm to the Contractor. 0'1 N ,J Benjamin Greenstein A& �t� C I� Greenstein Construction, Inc. 13 '�t gill ���1J� Y,` tir- ,Wl ® a� k44 Aff 16 4A Yl oMi SolVer Structural Partnership, Inc. Z Consulting Structural Engineers ' Design • Inspections • Investigation • Reports Partne p I nd March 6, 2013 Pagel of 2 Attention: Mr. Norman Bruhn Miami Shore Village Building Division.10050 NE 2°d Ave. Miami Shores, Fl. 33138 Re: Miramonte Residence. Answer to comments. Process Number: 12-1570 Buildine• Comment: #1 Answer: By others Comment #2 Answer: Answer: I, Denis K. Solano, am a Professional Engineer and General Contractor in the State of Florida with extensive knowledge and expertise in single family homes. The Board of Professional Engineers, with the State of Florida approval, allows Professional Engineers to sign/seal plans for other trades as long as the individual has extensive knowledge and experience on this particular trade. This job is also a simple addition to an existing residence without no complex architectural "design" or "expertise" involved. Comment #3 Answer: This Alteration is a level 2 alteration not a level 3 since the total area added does not exceed 50% of the overall area of the existence residence. Please, refer to the attached area calculation for your reference only. Comment #4 Answer: By others. Plans show pergola, fence, walkways and roof by others Comment #5 Answer: The fill note is a General note that might be applicable if for any reason fill must be to the site to level some grade "valleys". Comment #6 Answer: Refer to Legend on S-1 for the corresponding wall shade. All bearing walls are shown with a specific shade. Comment #7 Answer: Shoring is by others ® 7500 N.W. 2e Street • Suite 205. Miami, Florida 33122 . Phone: (305) 592-9396 . Fax: (305) 599-9347 • • e -Mail: info@solver$tructural.com 9 0 2 2 Partnersh p, Inc: SolVer Structural Partnership, Inc. Consulting Structural Engineers Design • Inspections • Investigation a Reports Comment #8 Answer: Please, refer to existing plans from dimensions. Also, refer to our foundation plan S-1 footing". (12"&20"w). Please remember that this reference from Microfilm. Comment #9 Answer: Prefabricated trusses are by others. Page 2 of 2 Microfilm showing the existing foundation and Legend referring EWF as "existing wall is not an Alteration level 3; refer to attached Comment #10 Answer: Refer to the calculation package for the corresponding calculations of the new wood floors. Please remember that this is not a ALTERA'T'ION LEVEL 3. Comment #I I Answer: Windows and doors shop drawings is to be provided "By Others" Comment #12 Answer: Roofing application is by others. Comment #13 - Answer: All new and existing 8" CMU walls shown on plans are bearing walls forming part of the. MWFRS. Refer to sections provided thru out the structural plans. Comment # 14 Answer: Refer to A-4 and energy calculations by the MEP engineer. Structural: Comment #1 Answer: Shoring is to be provided "By others". Comment #2 Answer: Concrete tie columns are not needed since we are proposing a "reinforced wall" system and not an "unreinforced masonry" wall type system. If you have any questions, please contact my office at your earliest convenience. Kind Regards, Denis K. Solano, P.E. #: 56904 S.I. #: 2046 President Solver Struct;2eSt rship, Inc. (305) 592-9396 Phone/ (305) 599-9347 Fax 7500 N.Wt a Suite 205 . Miami, Florida 33122 . Phone: (305) 592-9396 . Fax: (305) 599-9347 . • 0 -Mall: lnfo@solverstructural.com . N SolVer Structural Partnership, Inc. Consulting Structural Engineers aDesign • Inspections • Investigation • Reports a Padke sh p Inc March 6, 2013 Page 1 of 2 Attention: Mr. Norman Bruhn Miami Shore Village Building Division -10050 NE 2°d Ave. Miami Shores, Fl. 33138 Re: Miramonte Residence. Answer to comments. Proem Number: 12-1570 BuBu- Comment: #1 Answer: By others Comment #2 Answer: Answer: I, Denis K. Solano, am a Professional Engineer and General Contractor in th State of Florida with extensive knowledge and expertise in single fe family homes. The Board e Professional Engineers, with the State of Florida approval, allowsProfessional Engineers to sign/seal plans for other trades as long as the individual has extensive knowledge and experience on this particular trade. This job is also a simple addition to an existing residence without no complex architectural "design' or "expertise" involved. Comment #3 Answer. This Alteration is a level 2 alteration not a level 3 since the total area added does not exceed 50% of the overall area of the existence residence. Please, refer to the attached area calculation for your reference only. Comment #4 Answer. By others. Plans show pergola, fence, walkways and roof by others Comment #5 Answer: The fill note is a General note that might be applicable if for any reason fill must be to the site to level some grade "valleys". Comment #6 Answer: Refer to Legend on S-1 for the corresponding wall shade. All bearing walls are shown with a specific shade. Comment #7 Answer: Shoring is by others • 7500 N.W. 2e Street • Suite 205 • Miami, Florida 33122 • Phone: (305) 592-9396 • Fax: (305) 599-9347 • • e -Mail: info&olverstructural.com • V, N SolVer Structural Partnership, Inc. Consulting Structural Engineers Design • Inspections • Investigation • Reports Partne p Inc Comment #8 Page 2 of 2 Answer: Please, refer to existing plans from Microfilm showing the existing foundation dimensions. Also, refer to our foundation plan S-1 and Legend referring EWF as "existing wall footing". (12"dx20"w). Please remember that this is not an Alteration level 3; refer to attached reference from Microfilm, Comment #9 Answer: Prefabricated trusses are by others. Comment #10 Answer. Refer to the calculation package for the corresponding calculations of the new wood floors. Please remember that this is not a ALTERATION LEVEL 3. Comment #11 Answer: Windows and doors shop drawings is to be provided "By Others" Comment #12 Answer: Roofing application is by others. Comment # 13 Answer: All new and existing 8" CMU walls shown on plans are bearing walls forming part of the MWFRS. Refer to sections provided thru out the structural plans. Comment #14 Answer. Refer to A-4 and energy calculations by the MEP engineer. Stractaral• Comment #I Answer: Shoring is to be provided `By others". Comment #2 .Answer: Concrete tie columns are not needed since we are proposing a "reinforced wall" system and not an "unreinforced masonry" wall type system. If you have any questions, please contact my office at your earliest convenience. Kind Regards, Denis K. Solano, P.E. #: 56902, S.I. #: 2046 President �rtnership, Solver Structural Inc. (305) 592-9396 Phone/ (305) 599-9347 Fax • 7500 N.W. 2e't2jreet • Suite 205 • Miami, Florida 33122 • Phone: (305) 592-9396 • Fax: (305) 599-9347 • 9 e -Mail: info@solverstructural.com • I OOL 4 Solver Structural Partnership, Inc. m Consulting Structural Engineers Design • Inspections • Investigation • Reports s x_ Partnership, In `' September 7, 2012 Page 1 of 4 Attention: Mr. Norman Bruhn Miami Shore Village Building Division 10050 NE a Ave Miami Shores, FL 33138 Rei Miramonte Residence Process -Num ber. 12-1570 Comment: #1 Answer: Submitted Comment #2 Answer: Impact fee paid by owner Comment #3 Answer: Submitted Comment #4 Answer: I, Denis K. Solan, am a Professional Engineer and General Contractor in the State of Florida with extensive knowledge and expertise in single family homes. The Board of Professional Engineers, with the State of Florida approval, allows Professional Engineers to sign/seal plans for other trades as long as the individual has extensive knowledge and experience. This job is also a simple addition to an existing residence. Comment #5 Answer: Please, refer to Electrical Notes in sheet E-3 Comment #G Answer: Level 2, Please refer to note in sheet A-1 Comment #7 Answer. See, scope of work in sheet A-1 Comment #8 Answer: Please be more specific; have not found note in question. • 7500 N.W. 25* Street • Suite 205 • Miami, Florida 33122 • Phone: (306) 692-9396 • Fax: (305) 599-9347 • • e -Mail: lnfo@solvomtructural.com • 0 S®IVer Structural Partnership, Inc. Consulting Structural Engineers Design • Inspections • Investigation • Reports 2 e Partnership, In Page 2 of 4 Comment #9 Answer. Was submitted Comment #10 Answer: Refer to legend on foundation plan (S-1) where bearing walls are shown with an specific shade. Comment #11 Answer. Shoring plans is to be provided `By Others" Comment #12 Answer. Please, refer to existing plans from Microfilm showing the existing foundation dimensions. Also, refer to foundation plan referring EWF as EWF (12"dx20"w). Comment #13 Answer: All new and existing 8" CMU walls shown on plans are bearing walls forming part of the MWFRS. Comment #14 Answer. Detail A/S-8 is indeed "C" on S-6. Comment #15 Answer: Please, refer to revised second floor plan and beam schedule on S-2. Comment #16 Answer. Please, refer to attached special inspector form. Comment #17 Answer. Truss plans is to be provided "By Others" Comment #18 Answer. Please, refer to attached calculations Comment #19 Answer: Product approvals for new windows and doors shall be under a separate permit Comment #20 Answer: Please, refer to revised elevations on S-4 and S-5 where architectural denomination has been added besides out. Also, refer to legend for additional clarification. • 7500 N.W. 2e Street • Suite 205 • Miami, Florida 33122 • Phone: (305) 592-9396 • Fax: (305) 599-9347 • • e -Mail: info@solverstructural.com • SolVer Structural Partnership, Inc. Consulting Structural Engineers Design • Inspections • Investigation • Reports Panners 1p, l Page 3 of 4 Comment #21 Answer: Please, refer to revised detail on S-11. Comment #22 Answer: Spiral stair and landing detail are `By Others", refer to note added on S-2. Comment #23 Answer. Spiral stair and landing detail are `By Others", refer to note added on S-2. Comment #24 Answer: Comment #25 Answer. Unvented attic, Please refer to note sheet A-4. Comment #26 Answer: No new interior bearing walls; all new bearing walls are shown in our plans with the corresponding shade as per legend on S-2. Comment #27 Answer: This was; a drafting error; please refer to revised detail D/S-6 Comment #28 Answer: is coordinated, refer to D-1, A-2 and A-3 Structural: Comment #1 Answer: Shoring is to be provided `By others". Comment #2 Answer: Please be more specific, as per my review A-2 and S-2 are matching. No discrepancies shown. Comment #3 Answer. Please, refer to detail 1/S-9. Comment #4 Answer: Please, refer to detail 2/S-10. • 7500 N.W. 2e Street • Suite 205 • Miami, Florida 33122 • Phone: (305) 592-9396 • Fax: (305) 599-9347 • • e -Mail: info@solvemtructural.com • 0 z � Partnershl ,ln So1Ver Structural Partnership, Inc. Consulting Structural Engineers Design • Inspections • Investigation • Reports Page 4 of 4 Comment #5 Answer. Please, refer to detail 1/S-8. Comment #6 Answer. Please, refer to detail D/S-6. Comment #7 Answer: Please, refer to attached copy from Microfilm. Comment #8 Answer: Please, refer to attached N.O.A straps. Comment #9 Answer: Please, refer to attached special inspector form. Comment #10 Answer: Spiral stair and landing detail are `By Others", refer to note added on S-2. Comment #11 Answer. Please, refer to revised foundation plan (S-1). Comment #12 Answer: Please, refer to Design Loads on structural note #11 on 5-11. If you have any questions, please contact my office at your earliest convenience. Kind Regards, Denis K. Solano, P.E. #: 56902, S.I. #: 2046 President Solver Structural Partnership, Inc. 7500 NW 25`h Street, Suite 205 Miami� Fl. 33122 (305) 592-9396 Phone (305) 599-9347 Fax www.solversp.com • 7500 N.W. 210 Street • Suite 205 • Miami, Florida 33122 • Phone: (305) 592-9395 • Fax: (305) 599-9347 • . e -Mail: lnfo@solverstructural.com • FLORIDA DEPARTNIBNT OF Rick Scott l 3� 1 John H. Armstrong, MD, FACS Governor State Surgeon General November 06, 2012 (A Super Septic) 7701 W 18 Lane Hialeah, FL 33014 RE: Contingency Letter Application Document No:AP1085929 Centrax Permit Number: 13 -SC -1435102 OSTDS Number: 674 Grand Concorse Miami, FL 33138 Lot:5 Block: 102 Subdivision: Miami Shores Sec 4 Dear Applicant: This will acknowledge receipt of an application dated 10/15/2012 for a permit to use an existing onsite sewage treatment and disposal system located on the above referenced property. From a review of your completed application, it has been determined that your existing system is adequate for the proposed use (house remodeling and addition of 2nd floor garage). If you have any questions on this matter, please call our office at (305) 623-3500. Enclosures cc: Miami -Dade County Health Department 1725 NW 167 St, Opa Locka, FL 33056 Phone: (305) 623-3500 . Fax: (305) 623-3645 . http://www.MyFloridaEl-Lcom ialist II i s4orej Uh 10050 N.E. SECOND AVE. M1W SHORES, FLORIDA 33138-2382 Telephone: (305) 795-2207 Fax: (305) 756-8972 DAVID A. DACQUISTO, AICP PLANNING 5 ZONING DIRECTOR DEVELOPMENT ORDER File Number: PZ -5-12-201218 Property Address: 674 Grand Concourse Property Owner/Applicant: Carlos & Barbara Miramontes Address: 6767 Collins Ave. #2200 Miami Beach, FL. 33141 Agent: Denis Solano & Samir Kafruni Address: 7500 N.W. 25`6 Street, Miami, FL 33122 Whereas, the applicant Carlos & Barbara Miramontes (Owner), has filed an application for site plan review before the Planning Board on the above property. The applicant sought approval as follows: Special site plan review and approval. Addition and remodeling to main residence and accessory structure. Whereas, a public hearing was held on June 28, 2012 and the Board, after having considered the application and after hearing testimony and reviewing the evidence entered, finds: 1. The application was made in a manner consistent with the requirements of the Land Development Code of Miami Shores Village. 2. The conditions on the property and the representations made at the hearing merit consideration and are consistent with the requirements of the Land Development Code. The Board requires that all further development of the property shall be performed in a manner consistent with the site plan, drawings, and the conditions agreed upon at the hearing: 1) Approval is granted to add a 268 square foot main floor kitchen expansion and staircase, a front entry and a 590 square foot second story master suite addition. 2) Approval is granted to remodel the main floor interior of an existing accessory structure to remodel a cabana room and add a living room. 3) Approval is granted to add a 480 square foot second story to an existing accessory structure adding a bathroom, study, play room and music room. Pagel of 2 DO PZ -5-12-201218 Miramontes 4) Applicant to provide and maintain not less than two (2) parking spaces on the plot. 5) Applicant to obtain all required building permits before beginning work. b) Applicant to meet all applicable code provisions at the time of permitting. 7) Applicant to complete a covenant in the form of a "Declaration of Use" assuring the property is used only for a single family purpose, record the covenant with the Miami -Dade County Recorder and provide the planning director with a copy of the recorded document prior to the final inspection by the Building Official. 8) This zoning permit will lapse and become invalid unless the work for which it was approved is started within one (1) year of the signing of the development order by the board chair, or if the work authorized by it is suspended or abandoned for a period of at least one (1) year. The application with conditions was passed and adopted this 28a' day of June, 2012 by the Planner and Zoning Board as follows: Mr. Abramitis ABSE Mr. Busta YES Mr. Reese YES Mr. Madsen YES Chairman Fernandez YES DO PZ -5-12-201218 Mi=ont" Chairman, Planing Board Page 2 of 2 aw On - 9& 1) -lS e 4co o� CERTIFICATE F LIABILITY INSURANCE � DA-M(M DDM" THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE H5122120-13 OLDER, THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT. If the certificate holder is an ADDITIONAL INSURED, the policy(las) must be endorsed. if SUBROGATION 13 WAIVED, subject to the terms and conditions Of the policy, certain policies may require an endorsement. A statement an this certificate does not confer rights to the certificate holder In [IOU of such andomamantkI PRODUCER INSORIM Imppact Staff Leasing, Inc. 25D W. Indiantown Rd. Suite 1 D8 Jupiter FL $3458 )ns, LLC. ID: (Impact) Inc. site 108 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED ENAM D ABOSION VE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDINQ ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE API'ORDED BY THE POLICIES DESCRIBED HEREIN 13 SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED 6Y PAID CLAIMS. TYPe O MMSLMAroCE P "^-HUMBER CUCY cP MWERALLIAe1LrrY 1M— 1MIAIDDMYYYI LfMng COMMERCIAL DENEIM LIAftr y CLAIMS.MADE OCCUR CSEN7 A©QIleGATE LIMITAPpWES PCR: — POLICY . LO* AUTOMOBILE LIABILITY ANY AUTO AUTOSAll NVED E] UR UL ED ED HIRALMOS NON WNEO AUTOS UMBRELLALIAB OCCUR Ef(OE88 LULB CLAIMS -MADE DED RCMWn0N$ A wORK'ERSCOMPtmBATION AM EAPLOYEMB, UABIUTY Y 1 N WOPEODOOON603ANY 8/15/2012 8/15/2013 ,M..' ERIIlIEmSER 1XCLUDEW ERMnCUTA�E N 1 A (M�naetory in NIR B Workers Compensation C Excess Coverage ADORD tet, A04111-0 Romnkb SCNedulo, HmpPo � EACH 3 BODILY INJURY (Per Dotson) S 6ODILY INJURY (Por 000l4gni) R EACH OCCUARENCE Is AISGREGATE $ 6 E.L. DISEASE - POLICY LIMIT I S This Is for Informationel purposes and nothing shelf create any right Coverage provided for all leased employees but not subcontractors of Continental Malrrtananoe and Cpnsturction, LLC Client Effectiva: 4/xg/2013 1265 !j8MR@ELL.4BQ1K MIAMI SHORES BUILDING DEPARTMENT SHOKID ANY OF THE ABOVE DESCRIBQb POLICIES BE CANCELt O BEFORE 10050 NE 2ND AVE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN MIAMI SHORES FL 33138 ACCOR13ANCE VVIM THE POLICY PROVISIONS. AUTHORD:ED REPRESENTAnvE Glen J Distefano � ACORD 25 (201 Clog) 0 1988-2010 The gCORD name and logo are registered marks of A QRD RD CORPORATION. All rights reserved. CSRT .s 1543G47a ICtmnrn B*Un9Arren 5122/2011.5=32,32 Am tags 1 qP 1 Miami Shores Village r Building Department 143 /1 10050 N.E.2nd Avenue Miami Shores, Florida 33138 11:F Tel: (305) 795.2204 eZ� %,� a Fax: (305) 756.8972 g4lwp4vI-D6D.j -'` C eo ",-11,15 Permit No. A- -f ra 44/V72 -S AJ UZW 10 6, Job Name Date 8-22--1 °L STRUCTURAL CRITIQUE H ET, Say -46- u vw -1 -FDA 6*0- 64 E S.ct w '-) &.-2— 'yw N o-" ., 00 e%N C `D E rjv l�i'-fi o nV F L 47d A-- 414-i oz 20 gC is S'WawnP, () rJ tv Spa w®iJ 91 t A& W -F8 c- CZell �,"" r tv Spa w®iJ 91 t A& W -F8 c- CZell �,"" GUERRERO/GONZALEZ ENGINEERS, INC. E 780 Tamiami Canal Road Miami, FL 33144 (305) 262-3944 Fax (305) 262-8211 Monday, November 18, 2013 City of Miami Shores Mechanical Inspector Miami Shores, Florida Re: Miramontes Residence Dear Sir: This letter shall serve as certification by me Michael C. Guerrero, the engineer of record for the above referenced project. The insulation installed on the outside walls is R-5. This meets with my approval and that of the Florida Building Code. If you have any questions, please do not hesitate to give us a call. Sincerely, Mi ael C. Gue rero, P.E. Mechanical Engineer SolVer Structural Partnership, Inco m Consulting Structural Engineers Design • Inspections • Investigation • Reports Partners p In . November 1st, 2013 Miami Shores Village Building Department 10050 NE 2nd Avenue Miami Shores, Florida 33138 Re: Miramontes Residence 674 Grand Concourse, Miami Shores, FL. Permit #: RC121570 Building Official: This letter is to inform you that to the best of my knowledge, belief and professional judgment I certify that the construction at the above referenced project in regards to the mandatory structural inspections meets the intent of the Florida Building Code 2010 edition, and is in substantial accordance with the approved drawings and specifications. Should you have any questions please feel free to contact me at the above number. Sincerely, Denis K. Solano, P.E. #: B6902, S.I. #: 2046 President Solver Structural Partnership, Inc. • 950 NW 22nd Avenue • Miami, Florida 33125 • Phone: (305) 643-8699 • Fax: (305) 643-8692 • 9 e-mail: info@solverstructural.com• FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MIRAMONTES RES REMODELING Builder Name: Street: 674 GRAND CONCOURSE Permit Office: MIAMI SH ES City, State, Zip: MIAMI SHORES, FL, - Permit Number. Owner MR. AND MRS.CARLOS MIRAMONTES Jurisdiction: 232600 Design Location: FL, Miami 1. New construction or existing Existing (Projects 9. Wall Types (3438.0 s ft ) la n Area 2. Single family or multiple family Single-family a. Concrete Block -Inti .. ri r R=4.1 3438.00 ft2 3. Number of units, if multiple family 1 b. WA c. WA R= ft2 R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1823.0 sgft.) Insulation Area a. Cathedral/Single Assembly (Unvented) R=30.0 1666.00 ft2 6. Conditioned floor area above grade (ft2) 2751 b. Knee Wall (Unvented) R=30.0 157.00 ft2 Conditioned floor area below grade (ft2) 0 c. WA R= ft2 7. Windows(523.8 sgft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main R ft2 6 380 a. U -Factor. Sgt, U=1.09 523.75 ft2 b. Sup: Attic, Ret: Attic, AH: Master Bedroom 6 220 SHGC: SHGC--0.50 b. U -Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:18.00 c. U -Factor. WA ft2 b. Central Unit 24.6 SEER:18.50 SHGC: 13. Heating systems kBtu/hr Efficiency d. U -Factor. WA ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 0.873 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems 8. Floor Types (1666.0 sgft.) Insulation Area a. Natural Gas Tankless Cap: 1 gallons a. Slab -0n -Grade Edge Insulation R=0.0 1666.00 ft2 b. Conservation features EF: 0.891 b. N/A R= ft2 None c. WA R= ft2 15. Credits . Pstat Glass/Floor Area: 0.190 Total Proposed Modified Loads: 63.89 PASS Total Standard Reference Loads: 82.22 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates compliance with the Florida Energy Code.; PREPARED BY: Before construction is completed DATE: this building will be inspected for +� compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. ''p� OWNER/AGENT: a BUILDING OFFICIAL: zapol DATE: DATE: - Compliance requires certifica 4n by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Cool sys #2 may be undersized. Size of 24.6 was Increased to 24.6 for simulation. Please review the Manual A report 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 PROJECT Title: MIRAMONTES RES REMOD Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2751 Lot # Owner. MR. AND MRS.CARLOS MIR Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 674 GRAND CONCOU Permit Office: MIAMI SHORES Cross Ventilation: County: MIAMI -Dade Jurisdiction: 232600 Whole House Fan: City, State, Zip: MIAMI SHORES, Family Type: Single-family FL, - New/Existing: Existing (Projected) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5% Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI_INTL AP 1 51 90 70 75 149.5 56 Low BLOCKS Number Name Area Volume 1 Block1 1666 16660 2 Block2 1085 9765 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1666 16660 Yes 8 0 1 Yes Yes Yes 2 Master Bedroom 1085 9765 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 209 ft 0 1666 ft2 — 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat file/slate 1805 ft2 0 ft2 Medium 0.65 No 0.9 No 30 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full cathedral ceilin Unvented 0 1666 ft2 N N 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 CEILING # Ceiling Type Space R -Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvddhider Bedroom 30 1085 ft2 0.11 Wood 2 Cathedral/Single Assembly (Unvented Main 30 581 ft2 0.11 Wood 3 Knee Wall (Unvented) Master Bedroom 30 157 ft2 0.11 Wood WALLS Omt Adjacent Space 10 Wall TVPFk Cavity _ Width Height Sheathing Framing Solar Below 1 W Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 sorc 0.75 0 -2 N Exterior Concrete Block - Int Insul Main 4.1 34 10 340 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 4.1 66 10 660 1112 0 0.75 0 4 S Exterior Concrete Block - Int Insul Main 4.1 30 10 300 ft2 0 0.75 0 5 W Exterior Concrete Block - Int InsMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 6 N Exterior Concrete Block - Int InsMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 7 E Exterior Concrete Block - Int InsMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 8 S Exterior Concrete Block - Int InsMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 -9 S Exterior Concrete Block - Int Insul Main 4.0999 6 6 10 65 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U -Value Width Height Area Ft In Ft In 1 W Wood Main None 0.46 4 7 6 30 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U -Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Metal Single (Tinted) Yes 1.09 0.5 10.5 ft2 0 ft 0 in 0 ft 0 in None None 2 W 1 Metal Single (Tinted) Yes 1.09 0.5 42.5 ft2 0 ft 6 in 8 ft 0 in None None 3 W 1 Metal Single (Tinted) Yes 1.09 0.5 12 ft2 0 ft 6 in 8 ft 0 in None None 4 N 2 Metal Single (Tinted) Yes 1.09 0.5 42.5 ft2 0 ft 6 In 8 ft 0 in None None 5 N 2 Metal Single (Tinted) Yes 1.09 0.5 42 ft2 0 ft 6 in 2 ft 0 in None None 6 E 3 Metal Single (Tinted) Yes 1.09 0.5 42.5 ft2 1 ft 10 in 1 ft 11 in None None 7 E 3 Metal Single (Tinted) Yes 1.09 0.5 60 ft2 2 ft 0 in 0 ft 10 in None None 8 E 3 Metal Single (Tinted) Yes 1.09 0.5 14 ft2 0 ft 6 in 8 ft 0 in None None 9 E 3 Metal Single (Tinted) Yes 1.09 0.5 70 ft2 0 ft 0 in 0 It 0 in None None 10 S 4 Metal Single (Tinted) Yes 1.09 0.5 5 ft2 0 ft 0 in 0 ft 0 in None None 11 W 5 Metal Single (Tinted) Yes 1.09 0.5 28 ft2 0 ft 6 in 2 ft 0 in None None 12 W 5 Metal Single (Tinted) Yes 1.09 0.5 25.5 ft2 0 ft 6 In 2 ft 0 in None None 13 N 6 Metal Single (Tinted) Yes 1.09 0.5 24 ft2 0 ft 6 in 2 ft 0 in None None 14 E 7 Metal Single (Tinted) Yes 1.09 0.5 24 ft2 2 ft 0 in 1 ft 4 in None None 15 E 7 Metal Single (Tinted) Yes 1.09 0.5 9 ft2 2 ft 0 In 1 ft 4 in None None 16 E 7 Metal Single (Tinted) Yes 1.09 0.5 14 ft2 2 ft 0 in 1 ft 4 in None None 17 S 8 Metal Single (Tinted) Yes 1.09 0.5 16 ft2 0 It 6 In 2 ft 0 in None None 18 E 7 Metal Single (Tinted) Yes 1.09 0.5 12 ft2 0 ft 6 in 2 ft 0 in None Exterior 5 19 E 7 Metal Single (Tinted) Yes 1.09 0.5 14 ft2 2 It 0 in 1 ft 4 In None Exterior 5 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. / # Wall Omt ID Frame Panes Overhang NFRC U -Factor SHGC Area Depth Separation Int Shade Screening 20 21 W 1 Metal Single (Tinted) Yes 1.09 0.5 5 ft2 0 ft 6 in 2 ft 0 in None S 9 Metal Single (Tinted) Yes 1.09 0.5 11.25 ft2 0 ft 6 in 2 ft 0 in None Exterior 5 Exterior 5 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 3607.9 198.07 372.50 0.4247 8.1921 HEATING SYSTEM #System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None COP: 1 34 kBtu/hr 1 None COP: 1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM #System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split SEER: 18 46.5 kBtu/hr 1395 cfin 0.74 1 None SEER: 18.5 24.6 kBtu/hr 738 cfm 0.72 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Main 0.82 1 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / # — Supply — Location R -Value Area — Return — Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 2 Attic 6 380 ft2 Attic 6 220 ft2 Attic 80 ft2 Default Leakage Main (Default) (Default) % Attic 80 ft2 Default Leakage Master Bed (Default) (Default) % 1 1 2 2 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating Jan Venting Feb Mar [ ] Apr May I Ry Jun Jun Jul Jul Au Aug Se Sep Oct Occtt Nov Nov Dec Dec Jan Feb Mar lxl X c Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 66 68 66 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 674 GRAND CONCOURSE PERMIT #: MIAMI SHORES, FL, - MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and / doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: t/ gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or , q�� other means proven to reduce heat loss except if 70% of heat from N site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency --78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 4/9/2013 4:25 PM EnergyGauge® USA - Flalles2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the EnergyPerformance Index, the more efficient the home. 674 GRAND CONCOURSE, MIAMI SHORES, FL, - 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows' Description a. U -Factor. Sgl, U=1.09 SHGC: SHGC=0.50 b. U -Factor. WA SHGC: c. U -Factor. WA SHGC: d. U -Factor. WA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab -On -Grade Edge Insulation b. WA c. WA Existing (Projects 9. Wall Types Insulation Single-family a. Concrete Block - Int Insul, Exterior R=4.1 ft2 b. N/A R= 1 c. WA R= 3 d. WA R= No 10. Ceiling Types Insulation 1666.00 ft2 a. Cathedral/Single Assembly (Unvented) R=30.0 2751 b. Knee Wall (Unvented) R=30.0 Area c. N/A R-- =523.75 523.75f12 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main b. Sup: Attic, Ret: Attic, AH: Master Bedroom ft2 Insulation R=0.0 R= R= I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Area 3438.00 ft2 ft2 fe ft2 Area 1666.00 ft2 157.00 ft2 ft2 R ft2 6 380 6 220 kBtu/hr Efficiency 46.5 SEER:18.00 24.6 SEER:18.50 kBtu/hr Efficiency 34.0 COP:1.00 17.0 COPA.00 Cap: 1 gallons EF: 0.82 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software 12. Cooling systems ft2 a. Central Unit b. Central Unit ft2 13. Heating systems a. Electric Strip Heat 0.873 ft. b. Electric Strip Heat 0.500 Area 14. Hot water systems 1666.00 ft2 a. Natural Gas ft2 ft2 b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Area 3438.00 ft2 ft2 fe ft2 Area 1666.00 ft2 157.00 ft2 ft2 R ft2 6 380 6 220 kBtu/hr Efficiency 46.5 SEER:18.00 24.6 SEER:18.50 kBtu/hr Efficiency 34.0 COP:1.00 17.0 COPA.00 Cap: 1 gallons EF: 0.82 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Florida Code -Summary Report MR. AND MRS.CARLOS MIRA Title: MIRAMONTES RES REMODELING TMY City: FL MIAMI INTL AP til: 674 GRAND CONCOURSE FLAsBuilt Elec UFlorid-a Average MIAMI SHORES, FL, - Gas Util: Florida Average Registration #: Run Date: Energy Uses Reference Home Proposed Home a -Ratio Heating 0.52 MBtu 0.58 MBtu 1.12 Cooling 29.71 MBtu 23.69 MBtu 0.80 Hot Water 12.90 MBtu 8.84 MBtu 0.69 Total 43.12 MBtu 33.11 MBtu 0.77 Building Loads Reference Home Proposed Home a -Ratio Heating 1.28 MBtu 1.38 MBtu* 1.08 Cooling 74.04 MBtu 59.11 MBtu* 0.80 Hot Water 6.90 MBtu 3.39 MBtu* 0.49 Total 82.22 MBtu 63.89 MBtu 0.78 * normalized modified loads Glass/Floor Area: 0.190 Total Proposed Modified Loads: 63.89 PASS Total Reference Loads: 82.22 4/9/2013 4:25 PM EnergyGauge® USA - RaRes2010 / Page 1 of 1 Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 1 of 5 PROJECT Title: MIRAMONTES RES REMOD Bedrooms: 3 Address Type: Street Address Building Type: User Bathrooms: 0 Lot # Owner. MR. AND MRS.CARLOS MIR Conditioned Area: 2751 sq.ft. Block/SubDMsion: # of Units: 1 Total Stories: 2 PlatBook: Builder Name: Worst Case: No Street: 674 GRAND CONCOU Permit Office: MIAMI SHORES Rotate Angle: 0 County: MIAMI -Dade Jurisdiction: 232600 Cross Ventilation: City, State, Zip: MIAMI SHORES, Family Type: Single-family Whole House Fan: FL, - New/Existing: Existing (Projected) Terrain: Suburban Year Construct: 2012 Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTL AP 51 90 70 75 149.5 56 Low UTILITY RATES Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Average 0 0.1144 Natural Gas Therm Florida Average 0 1.7386 Fuel Oil Gallon Florida Default 0 1.1 Propane Gallon Florida Default 0 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Omt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft FLOORS # Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation Main 209 ft 0 1666 fta _ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck J226 # Type Materials Area Area Color Absor. Tested Tested Insul. 1 Hi Flat tile/slate 1805 ft' 0 ft' Medium 0.65 No 0.9 No 30 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 1 of 5 Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 2 of 5 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full cathedral calling Unvented 0 1666 ft2 N N CEILING # Ceiling Type Space R -Value Area Framing Fraction Truss Type 1 Cathedral/Single Assembly 0 Master Bedroom 30 1085 ft2 0.11 Wood 2 Cathedral/Sfngle Assembly 0 Main 30 581 ft2 0.11 Wood 3 Knee Wall 0 Master Bedroom 30 157 ft2 0.11 Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. # Omt Ad* cant To Wall Type Spate Cavity R -Value Width Ft In Height Sheathing Framing Ft In Area R -Value Fraction Solar Below Absor. Grade% 1 W Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 0.75 0 2 N Exterior Concrete Block - Int Insul Main 4.1 34 10 340 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 0.75 0 4 S Exterior Concrete Block - Int Insul Main 4.1 30 10 300 ft2 0 0.75 0 5 W Exterior Concrete Block - Int InsuMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 6 N Exterior Concrete Block - Int InsuMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 7 E Exterior Concrete Block - Int InsuMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 8 S Exterior Concrete Block - Int InsuMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 9 S Exterior Concrete Block - Int Insul Main 4.0999 6 6 10 65 ft2 0 0.75 0 DOORS Width Height # Omt Door Type Space Storms U -Value Ft In Ft In Area 1 W Wood Main None 0.46 4 7 6 30 ft2 WINDOWS Wall Overhang # Omt ID Frame Panes NFRC U -Factor SHGC Storm Area Depth Separation Interior Shade Screening 1 W 1 Metal Single (Tinted) Yes 1.09 0.5 Y 10.5 ft2 0 ft 0 in 0 ft 0 in None None 2 W 1 Metal Single (Tinted) Yes 1.09 0.5 Y 42.5 ft2 0 ft 6 in 8 It 0 in None None 3 W 1 Metal Single (Tinted) Yes 1.09 0.5 Y 12 ft2 0 ft 6 in 8 ft 0 in None None 4 N 2 Metal Single (Tinted) Yes 1.09 0.5 Y 42.5 ft2 0 It 6 in 8 ft 0 in None None 5 N 2 Metal Single (Tinted) Yes 1.09 0.5 Y 42 ft2 0 ft 6 in 2 ft 0 in None None 6 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 42.5 ft2 1 ft 10 in 1 ft 11 in None None 7 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 60 ft2 2 ft 0 in 0 it 10 in None None 8 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 14 ft2 0 It 6 in 8 ft 0 in None None 9 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 70 ft2 0 ft 0 in 0 ft 0 in None None 10 S 4 Metal Single (Tinted) Yes 1.09 0.5 Y 5 ft2 0 ft 0 in 0 It 0 in None None 11 W 5 Metal Single (Tinted) Yes 1.09 0.5 Y 28 ft2 0 ft 6 in 2 ft 0 in None None 12 W 5 Metal Single (Tinted) Yes 1.09 0.5 Y 25.5 ft2 0 ft 6 In 2 it 0 in None None 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 2 of 5 Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 3 of 5 WINDOWS # Wall Omt ID Frame Panes NFRC U -Factor SHGC Storm Overhang Area Depth Separation Interior Shade Screening 13 14 15 16 17 18 19 20 21 N 6 Metal E 7 Metal E 7 Metal E 7 Metal S 8 Metal E 7 Metal E 7 Metal W 1 Metal S 9 Metal Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Single (Tinted) Yes Yes Yes Yes Yes Yes Yes Yes Yes 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 1.09 0.5 Y 24 ft2 0 ft 6 in 2 It 0 in 24 ft2 2 ft 0 in 1 ft 4 in 9 ft2 2 ft 0 in 1 ft 4 in 14 ft2 2 ft 0 in 1 ft 4 in 16 ft2 0 ft 6 in 2 ft 0 in 12 ft2 0 It 6 in 2 ft 0 in 14 ft2 2 ft 0 in 1 ft 4 in 5 ft2 0 ft 6 in 2 ft 0 in 11.25 ft2 0 ft 6 in 2 ft 0 in None None None None None None None None None None None Exterior 50% None Exterior 50% None Exterior 50% None Exterior 50% INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Space(s) 1 Wholehouse Best Guess 0.000500 3607.9 198.07 372.50 0.4247 8.1921 All MASS Mass Type Area Thickness Furniture Fraction Space No Added Mass No Added Mass 0 ft2 0 ft2 0 ft 0 ft 0.3 Main 0.3 Master Bedroom HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless Block 1 2 Electric Strip Heat Electric Strip Heat None None COP: 1 COP: 1 34 kBtu/hr False 17 kBtu/hr False 1 2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless Block 1 2 Central Unit Central Unit Split None SEER: 18 SEER: 18.5 46.5 kBtu/hr 1395 cfm 24.6 kBtu/hr 738 cfm 0.74 False 1 0.72 False 2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Credits 1 Natural Gas Tankless Main 0.82 1 gal 40 gal 120 deg None SOLAR HOT WATER Collector Type Collector Tilt Azimuth Surface Area Absorp. Trans Loss Coef. Prod. Corr. Tank Tank Tank Heat PV Pump Volume U -Value Surf Area Exch Eff Pumped Energy 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 3 of 5 Building Input Summary Report DUCTS DUCT Supply Return Air Percent HVAC # # Location R -Value Area Location Area Number Leakage Type Handler CFM 25 Leakage ON RLF Heat Cool 1 Attic 6 380 ft2 Attic 80 ft2 4 Default Leakage Main (Default) (Default) 1 1 2 Attic 6 220 ft2 Attic 80 ft2 3 Default Leaka a Master Bed Default Default 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Heatinay g Jan Feb [ j Mar LJ Apr M May Jun Jun l Ju Aug Sep Oct Nov Dec Venting Jan Feb Mar R] l Aug Sep Occtt X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 APPLIANCES & LIGHTING Appliance Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 % Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use: 0 kWhNr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.047 0.047 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 % Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Annual Use: 0 kWhNr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWhNr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1 % Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 Annual Use: 0 kWhNr Peak Value: 0 Watts Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11 % Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28 Annual Use: 2656 kWhNr Peak Value: 867 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 % Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 Annual Use: 4724 kWhNr Peak Value: 866 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 % Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0 Annual Use: 0 kWhNr Peak Value: 0 Watts Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 % Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWhNr Peak Value: 0 Watts Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 % Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWhNr Peak Value: 106 Watts WIM 4:26 PM AM 0.05 0.05 0.05 Enejfuge®9•b%RFZE9N.0 0.1 0.1 0.1 0.1 0.1 Page 400? 5 % Released: 0 PM 0.1 0.1 0.1 .1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWhNr Peak Value: 0 Watts Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 5 of 5 BLOCKS Number Name Area Volume 1 2 Blockl Block2 1666 1085 16660 9765 16660 9765 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 2 Main Master Bedroom 1666 1085 16660 9765 Yes 8 0 Yes Yes Yes No 4 3 Yes Yes Yes 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 5 of 5 System Sizing Calculations - Winter Residential Load - Whole House Component Details MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - Building Type: User 4/9/2013 Reference City: Miami, FL (Defaults) Winter Temperature Difference: 20.0 F (MJ8 99% Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 1, NFRC 0.50(StrMyletal 1.09 W 10.5 21.8 229 Btuh 2 1, NFRC 0.50(StrrrMetal 1.09 W 42.5 21.8 927 Btuh 3 1, NFRC 0.50(Stmiy9etal 1.09 W 12.0 21.8 262 Btuh 4 1, NFRC 0.50(StrrrMetal 1.09 N 42.5 21.8 927 Btuh 5 1, NFRC 0.50(StrrrMetal 1.09 N 42.0 21.8 916 Btuh 6 1, NFRC 0.50(StrrrMetal 1.09 E 42.5 21.8 927 Btuh 7 1, NFRC 0.50(StrrrMetal 1.09 E 60.0 21.8 1308 Btuh 8 1, NFRC 0.50(StrrrMetal 1.09 E 14.0 21.8 305 Btuh 9 1, NFRC 0.50(StrrrMetal 1.09 E 70.0 21.8 1526 Btuh 10 1, NFRC 0.50(StrrrMetal 1.09 S 5.0 21.8 109 Btuh 11 1, NFRC 0.50(StrrrMetal 1.09 W 28.0 21.8 610 Btuh 12 1, NFRC 0.50(StrrrMetal 1.09 W 25.5 21.8 556 Btuh 13 1, NFRC 0.50(StrrrMetal 1.09 N 24.0 21.8 523 Btuh 14 1, NFRC 0.50(StrryMetal 1.09 E 24.0 21.8 523 Btuh 15 1, NFRC 0.50(StrrrMetal 1.09 E 9.0 21.8 196 Btuh 16 1, NFRC 0.50(Strrrioetal 1.09 E 14.0 21.8 305 Btuh 17 1, NFRC 0.50(StrrrMetal 1.09 S 16.0 21.8 349 Btuh 18 1, NFRC 0.50(StrrrMetal 1.09 E 12.0 21.8 262 Btuh 19 1, NFRC 0.50(StrrrMetal 1.09 E 14.0 21.8 305 Btuh 20 1, NFRC 0.50(Strrr191etal 1.09 W 5.0 21.8 109 Btuh 21 1, NFRC 0.50(Stmiy9etal 1.09 S 11.3 21.8 245 Btuh Window Total 523.8 s ft 11418 Btuh Walls Type Omt. Ueff. R Value Area X HTM= Load (Cav/Sh) 1 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 560 2.98 1671 Btuh 2 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 256 2.98 763 Btuh 3 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 474 2.98 1413 Btuh 4 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 295 2.98 880 Btuh 5 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 401 2.98 1197 Btuh 6 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 228 2.98 681 Btuh 7 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 382 2.98 1139 Btuh 8 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 236 2.98 704 Btuh 9 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 54 2.98 160 Btuh Wall Total 2884 s ft 8609 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Exterior, n (0.460) 30 9.2 276 Btuh Door Total 30 s ft 27613tuh Ceilings Type/Color/Surface Ueff. R -Value Area X HTM= Load 1 Cathedral/L/Tile (0.016) 30.0/30.0 1085 0.3 356 Btuh 2 Cathedral/L/Tile (0.016) 30:0/30.0 581 0.3 191 Btuh 3 Knee Wall/L/Tile (0.017) 30.0/30.0 157 0.3 54 Btuh Ceiling Total 1823 s ft 601 Btuh EnergyGauge® / USRFZB v3.0 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - Building Type: User 4/9/2013 Floors 1 Type Ueff. R -Value Size X HTM= Slab On Grade (1.180) 0.0 209.0 ft(perim.) 23.6 Floor Total 1666 s ft Load 4932 Btuh 4932 Btuh Envelope Subtotal: 25836 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.68 26425 1.00 299.3 6583 Btuh Duct load (DLM of Mixed ducts) 6064 Btuh All Zones Sensible Subtotal All Zones 38483 Btuh Subtotal Sensible Heat Loss 38483 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 38483 Btuh 1. Electric Strip Heat 34000 Btuh 2. Electric Strip Heat 17000 Btuh Key: Window types - NFRC (Requires U -Factor and Shading coefflcient(SHGC) of glass as numerical values) or - Glass as 'Clear' or Taint (Uses U -Factor and SHGC defaults) U - (Window U -Factor) HTM - (ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge® / USRFZB v3.0 Page 2 System Sizing Calculations - Summer Residential Load - Whole House Component Details MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 Reference City: Miami, FL Temperature Difference: 15.OF(MJ8 99%) Humidity difference: 58gr. EnergyGauge® / USRFZB v3.0 Page 1 Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len Hgt Gross ShadedUnshadec Shaded Unshaded 1 1 NFRC 0.50, 1.09 No No W O.Oft O.Oft 10.5 0.0 10.5 27 65 684 Btuh 2 1 NFRC 0.50, 1.09 No No W 0.5ft 8.Oft 42.5 0.0 42.5 27 65 2767 Btuh 3 1 NFRC 0.50, 1.09 No No W 0.51t 8.Oft 12.0 0.0 12.0 27 65 781 Btuh 4 1 NFRC 0.50, 1.09 No No N 0.5ft 8.0ft 42.5 0.0 42.5 27 27 1156 Btuh 5 1 NFRC 0.50, 1.09 No No N 0.5ft 2.Oft 42.0 0.0 42.0 27 27 1142 Btuh 6 1 NFRC 0.50, 1.09 No No E 1.8ft 1.9ft 42.5 0.0 42.5 27 65 2767 Btuh 7 1 NFRC 0.50, 1.09 No No E 2.Oft 0,81t 60.0 13.2 46.8 27 65 3405 Btuh 8 1 NFRC 0.50, 1.09 No No E 0.5ft 8.01t 14.0 0.0 14.0 27 65 911 Btuh 9 1 NFRC 0.50, 1.09 No No E O.Oft O.Oft 70.0 0.0 70.0 27 65 4557 Btuh 10 1 NFRC 0.50, 1.09 No No S O.Oft O.Oft 5.0 0.0 5.0 27 29 144 Btuh 11 1 NFRC 0.50, 1.09 No No W 0.5ft 2.Oft 28.0 0.0 28.0 27 65 1823 Btuh 12 1 NFRC 0.50, 1.09 No No W 0.5ft 2.Oft 25.5 0.0 25.5 27 65 1660 Btuh 13 1 NFRC 0.50, 1.09 No No N 0.5ft 2.Oft 24.0 0.0 24.0 27 27 653 Btuh 14 1 NFRC 0-50,11.09 No No E 2.Oft 1.3ft 24.0 2.0 22.0 27 65 1488 Btuh 15 1 NFRC 0.50, 1.09 No No E 2.0ft 1.3ft 9.0 1.0 8.0 27 65 549 Btuh 16 1 NFRC 0-50,1.09 No No E 2.Oft 1.3ft 14.0 1.1 12.9 27 65 868 Btuh 17 1 NFRC 0.50, 1.09 No No S 0.5ft 2.Oft 16.0 10.7 5.3 27 29 443 Btuh 18 1 NFRC 0.50, 1.09 No H E 0.5ft 2.0ft 12.0 0.0 12.0 24 59 703 Btuh 19 1 NFRC 0.50, 1.09 No H E 2.Oft 1.3ft 14.0 1.1 12.9 24 59 781 Btuh 20 1 NFRC 0.50, 1.09 No H W 0.5ft 2.0ft 5.0 0.0 5.0 24 59 293 Btuh 21 1 NFRC 0-50,11.09 No H S 0.5ft 2.Oft 11.3 8.0 3.3 24 26 280 Btuh Window Total 524 (sqft) 27855 Btuh Walls Type U -Value R -Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hoilow - Ext 0.15 4.1/0.0 560.0 2.2 1254 Btuh 2 Concrete Blk,Holiow- Ext 0.15 4.1/0.0 255.5 2.2 572 Btuh 3 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 473.5 2.2 1060 Btuh 4 Concrete Blk,Holiow- Ext 0.15 4.1/0.0 295.0 2.2 660 Btuh 5 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 401.0 2.2 898 Btuh 6 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 228.0 2.2 510 Btuh 7 Concrete BIk,Hollow- Ext 0.15 4.1/0.0 381.5 2.2 854 Btuh 8 ConcreteBlk,Hollow - Ext 0.15 4.1/0.0 236.0 2.2 528 Btuh 9 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 53.8 2.2 120 Btuh Wall Total 2884 (sqft) 6456 Btuh Doors Type Area (sqft) HTM Load 1 Wood - Exterior 30.0 13.8 414 Btuh Door Total 30 (sqft) 414 Btuh Ceilings Type/Color/Surface U -Value R -Value Area(sqft) HTM Load 1 Cath/Sngl Assem/LightTle 0.016 30.0/30.0 1085.0 0.29 314 Btuh 2 Cath/Sngi Assem/Light/Tile 0.016 30.0/30.0 581.0 0.29 168 Btuh 3 Knee Wa1ULightTle 0.017 30.0/30.0 157.0 0.07 11 Btuh Ceiling Total 1823 (sqft) 492 Btuh Floors Type R -Value Size HTM Load 1 Slab On Grade 0.0 1666 (ft -perimeter) 0.0 0 Btuh Floor Total 1666.0 (sqft) 0 Btuh Envelope Subtotal: 35218 Btuh EnergyGauge® / USRFZB v3.0 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) MR. AND MRS.CARLOS MIRAMONTES Project Title: Climate: FL MIAMI_INTL AP 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 Infiltration Type Average ACH Volume(cuft) Wall Ratio CFM= Natural 0.51 26425 1 224.5 Load 3703 Btuh Internal gain Occupants Btuh/occupant Appliance 12 X 230 + 3400 Load 6160 Btuh Sensible Envelope Load: 45081 Btuh Duct load (DGMs vary for Mixed ducts) 3022 Btuh Sensible Load All Zones 48102 Btuh EnergyGauge® / USRFZB v3.0 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) MR. AND MRS.CARLOS MIRAMONTES Project Title: Climate: FL MIAMI_INTL AP 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 1. Central Unit RHEEM # 46500 Btuh 2. Central Unit RHEEM # 24600 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U -Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half dosed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) EnergyGauge® / USRFZB v3.0 Page 3 Sensible Envelope Load All Zones 45081 Btuh Sensible Duct Load 3022 Btuh Total Sensible Zone Loads 48102 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 48102 Btuh Totals for Cooling Latent infiltration gain (for 58 gr. humidity difference) 8851 Btuh Latent ventilation gain 0 Btuh Latent duct gain 2003 Btuh Latent occupant gain (12.0 people @ 200 Btuh per person) 2400 Btuh Latent other gain 4750 Btuh Latent total gain 18004 Btuh TOTAL GAIN 66107 Btuh 1. Central Unit RHEEM # 46500 Btuh 2. Central Unit RHEEM # 24600 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U -Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half dosed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) EnergyGauge® / USRFZB v3.0 Page 3 Residential System Sizing Calculation Summary MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(? ft.) Temp Range(L) Load Humidity data: Interior RH 50% Outdoor wet bulb 77F Humidity difference58 r. Window total 524 Winter design temperature(MJ8 99%) 50 F Summer design temperature(MJ8 99%) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter tem erature difference 20 F Summer temperature difference 15 F Total heatina load calculation 38483 Btuh Total coollinq load calculation 66107 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of talc Btuh Total (Electric Strip Heat) 132.5 51000 Sensible (SHR = 0.73) 108.4 52122 0 38483 Latent 105.4 18978 cfm 0 Btuh Total 107.6 71100 WINTER CALCULATIONS Winfor 1-Iccitinn I nori ffnr 77=4 —%% Load component Load Load Window total Window total 524 sgft 11418 Btuh Wall total 2884 sgft 8609 Btuh Door total 30 sgft 276 Btuh Ceiling total 1823 sgft 601 Btuh Floor total 1666 sgft 4932 Btuh Infiltration 299 cfm 6583 Btuh Duct loss Sens. Ventilation 0 cfm 6064 Btuh Subtotal 0 38483 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS Btuh Latent gain (Infiltration) 38483 Btuh Gummor r`nniinn I nnri ffnr 970.4 —4N Duds(18%) MOM Dear89 %) SUMMER CALCULATIONS Load component Load Window total 524 sgft 27855 Btuh Wall total 2884 sgft 6456 Btuh Door total 30 sgft 414 Btuh Ceiling total 1823 sgft 492 Btuh Floor total 0 Btuh Infiltration 224 cfm 3703 Btuh Internal gain 6160 Btuh Duct gain 3022 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 48102 Btuh Latent gain(ducts) 2003 Btuh Latent gain (Infiltration) 8851 Btuh Latent gain(ventilation) 0 Btuh Latent gain(intemaVoccupants/other) 7150 Btuh Total latent gain 18004 Btuh TOTAL HEAT GAIN 66107 Btuh Lateld k.1 rl49 N ed.oakla DOcS%) ma.( T"EM D-60%) Wawl 0%) EnergyGauge® System Sizing 8th Edition PREPARED BY: ''- DATE: EnergyGauge®/ USRFZB v3.0 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDI TION Florida Department of Business and Professional Regulation - Resid nt:F br K a hod Project Name: MIRAMONTES RES REMODELING Builder Name: - - Street: 674 GRAND CONCOURSE Permit Office: MIAMI SHO City, State, Zip: MIAMI SHORES, FL, - Permit Number wr," Owner: MR. AND MRS.CARLOS MIRAMONTES Jurisdiction: 232600 Design Location: FL, Miami 1. New construction or existing Existing (Projecte 9. Wall Types (3438.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3438.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= fie 5. Is this a worst case? No 10. Ceiling Types (1823.0 sqft.) Insulation Area a. Cathedral/Single Assembly (Unvented)R=30.0 1666.00 ft2 6. Conditioned floor area above grade (ft2) 2751 b. Knee Wall (Unvented) R=30.0 157.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(523.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 380 a. U -Factor: Sgl, U=1.09 523.75 ft2 b. Sup: Attic, Ret: Attic, AH: Master Bedroom 6 220 SHGC: SHGC=0.50 b. U -Factor: N/A {{2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:18.00 c. U -Factor: N/A ft2 b. Central Unit 24.6 SEER:18.50 SHGC: 13. Heating systems kBtu/hr Efficiency d. U -Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 0.873 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems 8. Floor Types (1666.0 sqft.) Insulation Area a. Natural Gas Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 1666.00 ft2 b. Conservation features EF: 0.891 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.190 Total Proposed Modified Loads: 63.89 PASS Total Standard Reference Loads: 82.22 I hereby certify that the plans and specifications covered by Review of the plans and �, ' S. this calculation are in compliance with the Florida Energy specifications covered by this p Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: 4 DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 hereby certify that this b' d ng, as designed, is in compliance Florida Statutes. with the Florida Energy Cod nws1� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: v - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Cool sys #2 may be undersized. Size of 24.6 was increased to 24.6 for simulation. Please review the Manual J8 report. 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 I I PROJECT Tale: MIRAMONTES RES REMOD Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2751 Lot # Owner: MR. AND MRS.CARLOS MIR Total Stories: 2 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 674 GRAND CONCOU Permit Office: MIAMI SHORES Cross Ventilation: County: MIAMI -Dade Jurisdiction: 232600 Whole House Fan: City, State, Zip: MIAMI SHORES, Family Type: Single-family FL, - New/Existing: Existing (Projected) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp �/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Miami FL_MIAMI_INTL AP 1 51 90 70 75 149.5 56 Low BLOCKS Number Name Area Volume 1 Block1 1666 16660 2 Block2 1085 9765 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1666 16660 Yes 8 0 1 Yes Yes Yes 2 Master Bedroom 1085 9765 No 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 209 ft 0 1666 ft2 r 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch �/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 1805 ft2 0 ft2 Medium 0.65 No 0.9 No 30 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full cathedral ceilin Unvented 0 1666 111:2 N N 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (UnvMtWer Bedroom 30 1085 ft2 0.11 Wood 2 Cathedral/Single Assembly (Unvented Main 30 581 ft2 0.11 Wood 3 Knee Wall (Unvented) Master Bedroom 30 157 ft2 0.11 Wood WALLS # Omt Adjacent Space TO Wall TypeRA-lahie Cavity Width Ft In Height Ft In Area Sheathing Framing R-Vallle Fraction Solar Absor Below 0 1 W Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 0.75 0 _ 2 N Exterior Concrete Block - Int Insul Main 4.1 34 10 340 ft2 0 0.75 0 _ 3 E Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 0.75 0 4 S Exterior Concrete Block - Int Insul Main 4.1 30 10 300 ft2 0 0.75 0 5 W Exterior Concrete Block - Int InsMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 _ 6 N Exterior Concrete Block - Int InsMaster Bedro 4.1 28 9 252 f1:2 0 0.75 0 _ 7 E Exterior Concrete Block - Int InsMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 _ 8 S Exterior Concrete Block - Int InsMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 9 S Exterior Concrete Block - Int Insul Main 4.0999 6 6 10 65 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Main None 0.46 4 7 6 30 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang 1/ # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Metal Single (Tinted) Yes 1.09 0.5 10.5 ft2 0 ft 0 in 0 ft 0 in None None 2 W 1 Metal Single (Tinted) Yes 1.09 0.5 42.5 ft2 0 ft 6 in 8 ft 0 in None None 3 W 1 Metal Single (Tinted) Yes 1.09 0.5 12 ft2 0 ft 6 in 8 ft 0 in None None 4 N 2 Metal Single (Tinted) Yes 1.09 0.5 42.5 ft2 0 ft 6 in 8 ft 0 in None None 5 N 2 Metal Single (Tinted) Yes 1.09 0.5 42 ft2 0 ft 6 in 2 ft 0 in None None 6 E 3 Metal Single (Tinted) Yes 1.09 0.5 42.5 ft2 1 ft 10 in 1 f1:11 in None None 7 E 3 Metal Single (Tinted) Yes 1.09 0.5 60 ft2 2 ft 0 in 0 ft 10 in None None 8 E 3 Metal Single (Tinted) Yes 1.09 0.5 14 ft2 0 ft 6 in 8 ft 0 in None None 9 E 3 Metal Single (Tinted) Yes 1.09 0.5 70 ft2 0 ft 0 in 0 ft 0 in None None 10 S 4 Metal Single (Tinted) Yes 1.09 0.5 5 ft2 0 ft 0 in 0 ft 0 in None None 11 W 5 Metal Single (Tinted) Yes 1.09 0.5 28 ft2 0 ft 6 in 2 ft 0 in None None 12 W 5 Metal Single (Tinted) Yes 1.09 0.5 25.5 ft2 0 ft 6 in 2 ft 0 in None None 13 N 6 Metal Single (Tinted) Yes 1.09 0.5 24 ft2 0 ft 6 in 2 ft 0 in None None 14 E 7 Metal Single (Tinted) Yes 1.09 0.5 24 ft2 2 ft 0 in 1 ft 4 in None None 15 E 7 Metal Single (Tinted) Yes 1.09 0.5 9 ft2 2 ft 0 in 1 ft 4 in None None 16 E 7 Metal Single (Tinted) Yes 1.09 0.5 14 ft2 2 ft 0 in 1 ft 4 in None None 17 S 8 Metal Single (Tinted) Yes 1.09 0.5 16 ft2 0 ft 6 in 2 ft 0 in None None 18 E 7 Metal Single (Tinted) Yes 1.09 0.5 12 ft2 0 ft 6 in 2 ft 0 in None Exterior 5 19 E 7 Metal Single (Tinted) Yes 1.09 0.5 14 ft2 2 ft 0 in 1 111:4 in None Exterior 5 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Omt ID Frame Panes NFRC Overhang U -Factor SHGC Area Depth Separation Int Shade Screening 20 21 W 1 Metal Single (Tinted) Yes S 9 Metal Single (Tinted) Yes 1.09 0.5 5 ft2 0 ft6 in 2 ft0 in None 1.09 0.5 11.25 ft2 0 ft6 in 2 ft 0 in None Exterior 5 Exterior 5 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 3607.9 198.07 372.50 0.4247 8.1921 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP: 1 34 kBtu/hr 1 COP: 1 17 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split None SEER: 18 46.5 kBtu/hr 1395 cfm 0.74 1 SEER: 18.5 24.6 kBtu/hr 738 cfm 0.72 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Main 0.82 1 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # — Supply — Location R -Value Area — Return — Air Percent Location Area Leakage Type Handler CFM 25 Leakage QN RLF HVAC # Heat Cool 1 2 Attic 6 380 ft2 Attic 6 220 ft2 Attic Attic 80 ft2 Default Leakage Main (Default) (Default) % 80 ft2 Default Leakage Master Bed (Default) (Default) % 1 1 2 2 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: HeOct ating Jan Feb Mar Ap Apr May Jun Jul Aug Sep j La Oct Nov Nov Dec Venting Jan Feb Mar Jun Jul Aug Sep LxJ X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/9/2013 4:25 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 674 GRAND CONCOURSE PERMIT #: MIAMI SHORES, FL, - MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: q/ gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or ��� other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 4/9/2013 4:25 PM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the EnergyPerformance Index, the more efficient the home. 674 GRAND CONCOURSE, MIAMI SHORES, FL, - 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U -Factor: Sgl, U=1.09 SHGC: SHGC=0.50 b. U -Factor: N/A SHGC: 1 c. U -Factor: N/A SHGC: d. N/A d. U -Factor. N/A SHGC: Insulation Area Weighted Average Overhang Depth: Area Weighted Average SHGC: Existing (Projecte 9. Wall Types Insulation Single-family a. Concrete Block - Int Insul, Exterior R=4.1 ft2 b. N/A R= 1 c. N/A R= 3 d. N/A R= No 10. Ceiling Types Insulation 1666.00 ft2 a. Cathedral/Single Assembly (Unvented) R=30.0 2751 b. Knee Wall (Unvented) R=30.0 Area c. N/A R= 523.75 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Main b. Sup: Attic, Ret: Attic, AH: Master Bedroom ft2 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Area 3438.00 ft2 ft2 ft2 ft2 Area 1666.00 ft2 157.00 ft2 ft2 R ft2 6 380 6 220 kBtu/hr Efficiency 46.5 SEER:18.00 24.6 SEERA8.50 kBtu/hr Efficiency 34.0 COP:1.00 17.0 COP:1.00 Cap: 1 gallons EF: 0.82 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software 12. Cooling systems ft2 a. Central Unit b. Central Unit ft2 13. Heating systems a. Electric Strip Heat 0.873 ft. b. Electric Strip Heat 0.500 Area 14. Hot water systems 1666.00 ft2 a. Natural Gas ft2 ft2 b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Area 3438.00 ft2 ft2 ft2 ft2 Area 1666.00 ft2 157.00 ft2 ft2 R ft2 6 380 6 220 kBtu/hr Efficiency 46.5 SEER:18.00 24.6 SEERA8.50 kBtu/hr Efficiency 34.0 COP:1.00 17.0 COP:1.00 Cap: 1 gallons EF: 0.82 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Florida Code Summary Report MR. AND MRS.CARLOS MIRA Title: MIRAMONTES RES REMODELING TMY City: FL_MIAMI AP 674 GRAND CONCOURSE FLAsBuilt _INTL Elec Util. Florida Average MIAMI SHORES, FL, - Gas Util: Florida Average Registration #: Run Date: Energy Uses Reference Home Proposed Home a -Ratio Heating 0.52 MBtu 0.58 MBtu 1.12 Cooling 29.71 MBtu 23.69 MBtu 0.80 Hot Water 12.90 MBtu 8.84 MBtu 0.69 Total 43.12 MBtu 33.11 MBtu 0.77 Building Loads Reference Home Proposed Home a -Ratio Heating 1.28 MBtu 1.38 MBtu* 1.08 Cooling 74.04 MBtu 59.11 MBtu* 0.80 Hot Water 6.90 MBtu 3.39 MBtu* 0.49 Total 82.22 MBtu 63.89 MBtu 0.78 * normalized modified loads Glass/Floor Area: 0.190 Total Proposed Modified Loads: 63.89 PASS Total Reference Loads: 82.22 4/9/2013 4:25 PM EnergyGauge® USA - RaRes2010 / Page 1 of 1 Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 1 of 5 PROJECT Title: MIRAMONTES RES REMOD Bedrooms: 3 Address Type: Street Address Building Type: User Bathrooms: 0 Lot # Owner: MR. AND MRS.CARLOS MIR Conditioned Area: 2751 sq.ft. Block/SubDivision: # of Units: 1 Total Stories: 2 PlatBook: Builder Name: Worst Case: No Street: 674 GRAND CONCOU Permit Office: MIAMI SHORES Rotate Angle: 0 County: MIAMI -Dade Jurisdiction: 232600 Cross Ventilation: City, State, Zip: MIAMI SHORES, Family Type: Single-family Whole House Fan: FL, - New/Existing: Existing (Projected) Terrain: Suburban Year Construct: 2012 Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTL AP 51 90 70 75 149.5 56 Low UTILITY RATES Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh Florida Average 0 0.1144 Natural Gas Therm Florida Average 0 1.7386 Fuel Oil Gallon Florida Default 0 1.1 Propane Gallon Florida Default 0 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Omt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft FLOORS # Floor Type Space Perimeter R -Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulation Main 209 ft 0 1666 ft' — 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 1805 ftz 0 ft2 Medium 0.65 No 0.9 No 30 22.6 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 1 of 5 Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 2 of 5 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full cathedral ceiling Unvented 0 1666 ft2 N N CEILING # Ceiling Type Space R -Value Area Framing Fraction Truss Type 1 Cathedral/Single Assembly Q Master Bedroom 30 1085 ft2 0.11 Wood 2 Cathedral/Single Assembly Q Main 30 581 ft2 0.11 Wood 3 Knee Wall Q Master Bedroom 30 157 ft2 0.11 Wood WALLS Wall orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. Adjacent Space Cavity Width Height Sheathing Framing Solar Below # Omt To Wall Type R -Value Ft In Ft In Area R -Value Fraction Absor. Grade% 1 W Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 0.75 0 2 N Exterior Concrete Block - Int Insul Main 4.1 34 10 340 ft2 0 0.75 0 3 E Exterior Concrete Block - Int Insul Main 4.1 66 10 660 ft2 0 0.75 0 4 S Exterior Concrete Block - Int Insul Main 4.1 30 10 300 ft2 0 0.75 0 5 W Exterior Concrete Block - Int InsuMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 6 N Exterior Concrete Block - Int InsuMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 7 E Exterior Concrete Block - Int InsuMaster Bedro 4.1 50 6 9 454.5 ft2 0 0.75 0 8 S Exterior Concrete Block - Int InsuMaster Bedro 4.1 28 9 252 ft2 0 0.75 0 9 S Exterior Concrete Block - Int Insul Main 4.0999 6 6 10 65 ft2 0 0.75 0 DOORS Width Height # Omt Door Type Space Storms U -Value Ft In Ft In Area 1 W Wood Main None 0.46 4 7 6 30 ft2 WINDOWS Wall Overhang # Omt ID Frame Panes NFRC U -Factor SHGC Storm Area Depth Separation Interior Shade Screening 1 W 1 Metal Single (Tinted) Yes 1.09 0.5 Y 10.5 ft2 0 ft 0 in 0 ft 0 in None None 2 W 1 Metal Single (Tinted) Yes 1.09 0.5 Y 42.5 ft2 0 ft 6 in 8 ft 0 in None None 3 W 1 Metal Single (Tinted) Yes 1.09 0.5 Y 12 ft2 0 ft 6 in 8 ft 0 in None None 4 N 2 Metal Single (Tinted) Yes 1.09 0.5 Y 42.5 ft2 0 ft 6 in 8 ft 0 in None None 5 N 2 Metal Single (Tinted) Yes 1.09 0.5 Y 42 ft2 0 ft 6 in 2 ft 0 in None None 6 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 42.5 ft2 1 ft 10 in 1 ft 11 in None None 7 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 60 ft2 2 ft 0 in 0 ft 10 in None None 8 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 14 ft2 0 ft 6 in 8 ft 0 in None None 9 E 3 Metal Single (Tinted) Yes 1.09 0.5 Y 70 ft2 0 ft 0 in 0 ft 0 in None None 10 S 4 Metal Single (Tinted) Yes 1.09 0.5 Y 5 ft2 0 ft 0 in 0 ft 0 in None None 11 W 5 Metal Single (Tinted) Yes 1.09 0.5 Y 28 f1:2 0 ft 6 in 2 ft 0 in None None 12 W 5 Metal Single (Tinted) Yes 1.09 0.5 Y 25.5 ft2 0 ft 6 in 2 ft 0 in None None 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 2 of 5 Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 3 of 5 WINDOWS # Wall Omt ID Frame Panes NFRC U -Factor SHGC Storm Overhang Area Depth Separation Interior Shade Screening 13 14 15 16 17 18 19 20 21 N 6 Metal E 7 Metal E 7 Metal E 7 Metal S 8 Metal E 7 Metal E 7 Metal W 1 Metal S 9 Metal Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes Single (Tinted) Yes 1.09 0.5 Y 24 ft2 0 ft 6 in 1.09 0.5 Y 24 ft2 2 ft 0 in 1.09 0.5 Y 9 ft2 2 ft 0 in 1.09 0.5 Y 14 ft2 2 ft 0 in 1.09 0.5 Y 16 ft2 0 ft 6 in 1.09 0.5 Y 12 ft2 0 ft 6 in 1.09 0.5 Y 14 ft2 2 ft 0 in 1.09 0.5 Y 5 ft2 0 ft 6 in 1.09 0.5 Y 11.25 ft2 0 ft 6 in 2 ft 0 in 1 ft 4 in 1 ft4 in 1 ft 4 in 2 ft 0 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 2 ft 0 in None None None None None None None None None None None Exterior 50% None Exterior 50% None Exterior 50% None Exterior 50% INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Space(s) 1 Wholehouse Best Guess 0.000500 3607.9 198.07 372.50 0.4247 8.1921 All MASS Mass Type Area Thickness Furniture Fraction Space No Added Mass No Added Mass 0 ft2 0 ft2 0 ft 0 ft 0.3 0.3 Main Master Bedroom HEATING SYSTEM # System Type Subtype Efficiency Capacity Ductless Block 1 2 Electric Strip Heat Electric Strip Heat None None COP: 1 COP: 1 34 kBtu/hr 17 kBtu/hr False False 1 2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless Block 1 2 Central Unit Central Unit Split None SEER: 18 SEER: 18.5 46.5 kBtu/hr 24.6 kBtu/hr 1395 cfm 738 cfm 0.74 False 1 0.72 False 2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Credits 1 Natural Gas Tankless Main 0.82 1 gal 40 gal 120 deg None SOLAR HOT WATER Collector Type Collector Surface Tilt Azimuth Area Absorp. Trans Loss Coef. Prod. Corr. Tank Tank Tank Heat PV Pump Volume U -Value Surf Area Exch Eff Pumped Energy 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 3 of 5 Building Input Summary Report DUCTS DUCT Supply Return Air Percent HVAC # # Location R -Value Area Location Area Number Leakage Type Handier CFM 25 Leakage QN RLF Heat Cool 1 Attic 6 380 ft2 Attic 80 ft' 4 Default Leakage Main (Default) (Default) 1 1 2 Attic 6 220 ft2 Attic 80 ft2 3 Default Leakage Master Bed Default Default 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: N Heating Jan Feb Mar Apr May Jrj un Jul ri Aug [ j Sep L f Nov Dec Venting Jan Feb Mar Jun Jul Aug Sep lxl Occtt X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 APPLIANCES & LIGHTING Appliance Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 % Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.047 0.047 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 % Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1 % Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11 % Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28 Annual Use: 2656 kWh/Yr Peak Value: 867 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 % Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 Annual Use: 4724 kWh/Yr Peak Value: 866 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 % Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 % Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 % Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWh/Yr Peak Value: 106 Watts W$%��2 4:26 PM 0.05 0.05 0.05 Ener�ifuge@9-aRFZE9N.O 0.1 0.1 0.1 0.1 0.1 Page 40015 % Released: 0 PM 0.1 0.1 0.1 .1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Building Input Summary Report 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 5 of 5 BLOCKS Number Name Area Volume 1 2 Block1 Block2 1666 1085 16660 9765 16660 9765 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 2 Main Master Bedroom 1666 1085 16660 9765 Yes 8 0 Yes Yes Yes No 4 3 Yes Yes Yes 4/9/2013 4:26 PM EnergyGauge® / USRFZB v3.0 Page 5 of 5 System Sizing Calculations - Winter Residential Load - Whole House Component Details MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - Building Type: User 4/9/2013 Reference City: Miami, FL (Defaults) Winter Temperature Difference: 20.0 F (MJ8 99% Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 1, NFRC 0.50(Strnfoetal 1.09 W 10.5 21.8 229 Btuh 2 1, NFRC 0.50(Strrfjoetal 1.09 W 42.5 21.8 927 Btuh 3 1, NFRC 0.50(StrrrMetal 1.09 W 12.0 21.8 262 Btuh 4 1, NFRC 0.50(StrrrMetal 1.09 N 42.5 21.8 927 Btuh 5 1, NFRC 0.50(StrrrMetal 1.09 N 42.0 21.8 916 Btuh 6 1, NFRC 0.50(StrrrMetal 1.09 E 42.5 21.8 927 Btuh 7 1, NFRC 0.50(StrrrMetal 1.09 E 60.0 21.8 1308 Btuh 8 1, NFRC 0.50(Stmly9etal 1.09 E 14.0 21.8 305 Btuh 9 1, NFRC 0.50(StrrrMetal 1.09 E 70.0 21.8 1526 Btuh 10 1, NFRC 0.50(StrrrMetal 1.09 S 5.0 21.8 109 Btuh 11 1, NFRC 0.50(StrrrMetal 1.09 W 28.0 21.8 610 Btuh 12 1, NFRC 0.50(StrrrMetal 1.09 W 25.5 21.8 556 Btuh 13 1, NFRC 0.50(Strrrioetal 1.09 N 24.0 21.8 523 Btuh 14 1, NFRC 0.50(StrrrMetal 1.09 E 24.0 21.8 523 Btuh 15 1, NFRC 0.50(Strrrfoetal 1.09 E 9.0 21.8 196 Btuh 16 1, NFRC 0.50(StrrrMetal 1.09 E 14.0 21.8 305 Btuh 17 1, NFRC 0.50(Strnioetal 1.09 S 16.0 21.8 349 Btuh 18 1, NFRC 0.50(StrrrMetal 1.09 E 12.0 21.8 262 Btuh 19 1, NFRC 0.50(Strnioetal 1.09 E 14.0 21.8 305 Btuh 20 1, NFRC 0.50(StrrrMetal 1.09 W 5.0 21.8 109 Btuh 21 1, NFRC 0.50(StrrrMetal 1.09 S 11.3 21.8 245 Btuh Window Total 523.8 s ft 11418 Btuh Walls Type Omt. Ueff. R -Value Area X HTM= Load (Cav/Sh) 1 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 560 2.98 1671 Btuh 2 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 256 2.98 763 Btuh 3 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 474 2.98 1413 Btuh 4 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 295 2.98 880 Btuh 5 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 401 2.98 1197 Btuh 6 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 228 2.98 681 Btuh 7 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 382 2.98 1139 Btuh 8 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 236 2.98 704 Btuh 9 Conc Blk,Hollow - Ext (0.149) 4.1/0.0 54 2.98 160 Btuh Wall Total 2884 s ft 8609 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood - Exterior, n (0.460) 30 9.2 276 Btuh Door Total 30 s ft 2766tuh Ceilings Type/Color/Surface Ueff. R -Value Area X HTM= Load 1 CathedraVL/Tile (0.016) 30.0/30.0 1085 0.3 356 Btuh 2 Cathedral/L/Tile (0.016) 30:0/30.0 581 0.3 191 Btuh 3 Knee Wall/L/Tile (0.017) 30.0/30.0 157 0.3 54 Btuh CeilinTotal 1823 s ft 601 Btuh EnergyGauge® / USRFZB v3.0 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - Building Type: User 4/9/2013 Floors 1 Type Ueff. R -Value Size X HTM= Slab On Grade (1.180) 0.0 209.0 ft(perim.) 23.6 Floor Total 1666 s ft Load 4932 Btuh 4932 Btuh Envelope Subtotal: 25836 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.68 26425 1.00 299.3 6583 Btuh Duct load (DLM of Mixed ducts) 6064 Btuh All Zones Sensible Subtotal All Zones 38483 Btuh Subtotal Sensible Heat Loss 38483 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 38483 Btuh 1. Electric Strip Heat 34000 Btuh 2. Electric Strip Heat 17000 Btuh Key: Window types - NFRC (Requires U -Factor and Shading coefficient(SHGC) of glass as numerical values) or - Glass as 'Clear or Tint' (Uses U -Factor and SHGC defaults) U - (Window U -Factor) HTM - (ManualJ Heat Transfer Multiplier) EnergyGauge® / USRFZB v3.0 Page 2 System Sizing Calculations - Summer Residential Load - Whole House Component Details MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 Reference City: Miami, FL Temperature Difference: 15.OF(MJ8 99%) Humidity difference: 58gr. EnergyGauge® / USRFZB 0.0 Page 1 Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 1 1 NFRC 0.50, 1.09 No No W O.Oft O.Oft 10.5 0.0 10.5 27 65 684 Btuh 2 1 NFRC 0.50, 1.09 No No W 0.5ft 8.Oft 42.5 0.0 42.5 27 65 2767 Btuh 3 1 NFRC 0.50, 1.09 No No W 0.5ft 8.Oft 12.0 0.0 12.0 27 65 781 Btuh 4 1 NFRC 0.50, 1.09 No No N 0.5ft 8.Oft 42.5 0.0 42.5 27 27 1156 Btuh 5 1 NFRC 0.50, 1.09 No No N 0.5ft 2.Oft 42.0 0.0 42.0 27 27 1142 Btuh 6 1 NFRC 0.50, 1.09 No No E 1.8ft 1.9ft 42.5 0.0 42.5 27 65 2767 Btuh 7 1 NFRC 0.50, 1.09 No No E 2.Oft 0.8ft 60.0 13.2 46.8 27 65 3405 Btuh 8 1 NFRC 0.50, 1.09 No No E 0.5ft 8.Oft 14.0 0.0 14.0 27 65 911 Btuh 9 1 NFRC 0.50, 1.09 No No E O.Oft O.Oft 70.0 0.0 70.0 27 65 4557 Btuh 10 1 NFRC 0.50, 1.09 No No S O.Oft O.Oft 5.0 0.0 5.0 27 29 144 Btuh 11 1 NFRC 0.50, 1.09 No No W 0.51t 2.Oft 28.0 0.0 28.0 27 65 1823 Btuh 12 1 NFRC 0.50, 1.09 No No W 0.5ft 2.Oft 25.5 0.0 25.5 27 65 1660 Btuh 13 1 NFRC 0.50, 1.09 No No N 0.5ft 2.01t 24.0 0.0 24.0 27 27 653 Btuh 14 1 NFRC 0.50, 1.09 No No E 2.Oft 1.3ft 24.0 2.0 22.0 27 65 1488 Btuh 15 1 NFRC 0.50, 1.09 No No E 2.Oft 1.3ft 9.0 1.0 8.0 27 65 549 Btuh 16 1 NFRC 0.50, 1.09 No No E 2.Oft 1.3ft 14.0 1.1 12.9 27 65 868 Btuh 17 1 NFRC 0.50, 1.09 No No S 0.5ft 2.Oft 16.0 10.7 5.3 27 29 443 Btuh 18 1 NFRC 0.50, 1.09 No H E 0.5ft 2.Oft 12.0 0.0 12.0 24 59 703 Btuh 19 1 NFRC 0.50, 1.09 No H E 2.Oft 1.3ft 14.0 1.1 12.9 24 59 781 Btuh 20 1 NFRC 0.50, 1.09 No H W 0.5ft 2.Oft 5.0 0.0 5.0 24 59 293 Btuh 21 1 NFRC 0.50, 1.09 No H S 0.5ft 2.Oft 11.3 8.0 3.3 24 26 280 Btuh Window Total 524 (sqft) 27855 Btuh Walls Type U -Value R -Value Area(sqft) HTM Load Cav/Sheath 1 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 560.0 2.2 1254 Btuh 2 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 255.5 2.2 572 Btuh 3 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 473.5 2.2 1060 Btuh 4 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 295.0 2.2 660 Btuh 5 Concrete Blk,Hollow- Ext 0.15 4.1/0.0 401.0 2.2 898 Btuh 6 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 228.0 2.2 510 Btuh 7 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 381.5 2.2 854 Btuh 8 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 236.0 2.2 528 Btuh 9 Concrete Blk,Hollow - Ext 0.15 4.1/0.0 53.8 2.2 120 Btuh Wall Total 2884 (sqft) 6456 Btuh Doors Type Area (sqft) HTM Load 1 Wood - Exterior 30.0 13.8 414 Btuh Door Total 30 (sqft) 414 Btuh Ceilings Type/Color/Surface U -Value R -Value Area(sqft) HTM Load 1 Cath/Sngl Assem/LightTle 0.016 30.0/30.0 1085.0 0.29 314 Btuh 2 Cath/Sngl Assem/Light/Tile 0.016 30.0/30.0 581.0 0.29 168 Btuh 3 Knee Wall/Light/Tile 0.017 30.0/30.0 157.0 0.07 11 Btuh Ceiling Total 1823 (sqft) 492 Btuh Floors Type R -Value Size HTM Load 1 Slab On Grade 0.0 1666 (ft -perimeter) 0.0 0 Btuh Floor Total 1666.0 (sqft) 0 Btuh Envelope Subtotal: 35218 Btuh EnergyGauge® / USRFZB 0.0 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) MR. AND MRS.CARLOS MIRAMONTES Project Title: Climate: FL_M[AMU NTL AP 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 Infiltration Type Average ACH Volume(cuft) Wall Ratio CFM= Natural 0.51 26425 1 224.5 Load 3703 Btuh Internal gain Occupants Btuh/occupant Appliance 12 X 230 + 3400 Load 6160 Btuh Sensible Envelope Load: 45081 Btuh Duct load (DGMs vary for Mixed ducts) 3022 Btuh Sensible Load All Zones 48102 Btuh EnergyGauge® / USRFZB 0.0 Page 2 It a Manual J Summer Calculations Residential Load - Component Details (continued) MR. AND MRS.CARLOS MIRAMONTES Project Title: Climate: FL MIAMI_INTL AP 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 1. Central Unit RHEEM # 46500 Btuh 2. Central Unit RHEEM # 24600 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U -Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) EnergyGauge® / USRFZB v3.0 Page 3 Sensible Envelope Load All Zones 45081 Btuh Sensible Duct Load 3022 Btuh Total Sensible Zone Loads 48102 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 48102 Btuh Totals for Cooling Latent infiltration gain (for 58 gr. humidity difference) 8851 Btuh Latent ventilation gain 0 Btuh Latent duct gain 2003 Btuh Latent occupant gain (12.0 people @ 200 Btuh per person) 2400 Btuh Latent other gain 4750 Btuh Latent total gain 18004 Btuh TOTAL GAIN 66107 Btuh 1. Central Unit RHEEM # 46500 Btuh 2. Central Unit RHEEM # 24600 Btuh *Key: Window types (Panes - Number and type of panes of glass) (SHGC - Shading coefficient of glass as SHGC numerical value) (U - Window U -Factor) (InSh - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R)) - For Blinds: Assume medium color, half closed For Draperies: Assume medium weave, half closed For Roller shades: Assume translucent, half closed (IS - Insect screen: none(N), Full(F) or Half(%)) (Omt - compass orientation) EnergyGauge® / USRFZB v3.0 Page 3 ' � r Residential System Sizing Calculation Summary MR. AND MRS.CARLOS MIRAMONTES Project Title: 674 GRAND CONCOURSE MIRAMONTES RES REMODELING MIAMI SHORES, FL - 4/9/2013 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(? ft.) Temp Range(L) Humidi data: Interior RH 50% Outdoor wet bulb 77F Humiditv difference 58 r. sqft 11418 Winter design temperature(MJ8 99%) 50 F Summer design temperature(MJ8 99%) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 20 F Summer temperature difference 15 F Total heatina load calculation 38483 Btuh Total cooling load calculation 66107 Btuh Submitted heating capacity % of talc Btuh Submitted cooling capacity % of talc Btuh Total (Electric Strip Heat) 132.5 51000 Sensible (SHR = 0.73) 108.4 52122 38483 Btuh Ventilation Latent 105.4 18978 Btuh TOTAL HEAT LOSS Total 107.6 71100 Winter Haatinn I nand ffnr 77.x,1 crtftl WINTER CALCULATIONS D-As(16%) Load component Load Window total 524 sqft 11418 Btuh Wall total 2884 sqft 8609 Btuh Door total 30 sqft 276 Btuh Ceiling total 1823 sqft 601 Btuh Floor total 1666 sqft 4932 Btuh Infiltration 299 cfm 6583 Btuh Duct loss 6064 Btuh Subtotal 38483 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS 38483 Btuh In10.(17%) Dows(1 %) . Fkws(13%) SUMMER CALCULATIONS Summar ('nnlinn I nand lfnr 971;1 cnft) Load component Load Window total 524 sqft 27855 Btuh Wall total 2884 sqft 6456 Btuh Door total 30 sqft 414 Btuh Ceiling total 1823 sqft 492 Btuh Floor total 0 Btuh Infiltration 224 cfm 3703 Btuh Internal gain 6160 Btuh Duct gain 3022 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 48102 Btuh Latent gain(ducts) 2003 Btuh Latent gain(infiltration) 8851 Btuh Latent gain(ventilation) 0 Btuh Latent gain(intemal/occupants/other) 7150 Btuh Total latent gain 18004 Btuh TOTAL HEAT GAIN 66107 Btuh 8th Edition Latent �—ra � — trt.0aKs Ducts(8%) t,1u.( WaU922%) -6a: Atubws(42%) Dcors(1%) W81300%) EnergyGauge® System Sizing PREPARED BY: z4dlta"d DATE: EnergyGauge® / USRFZB v3.0