Loading...
MC-13-2853Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 nspection Number: INSP-204913 Permit Number: MC -12-13-2853 Inspection Date: September 29, 2014 Permit Type: Mechanical - Residential Inspector: Perez, JanPierre Owner: , Job Address: 102 NE 106 Street Miami Shores, FL 33138-2037 Project: <NONE> Contractor: MG EXCELLENCE SERVICE CORPORATION Buildina Department Comments Inspection Type: Final Work Classification: New AIC System Phone Number (786)371-8479 Parcel Number 1121360050080 Phone: (786)247-7067 NEW A/C INSTALLATION Infractio Passed comments INSPECTOR COMMENTS False V Inspector Comments Passed � f Failed El Correction Needed (� Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. For Inspections please call: (305)762-4949 September 29, 2014 Page 1 of 1 rm.Z. BUILDING Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 PERMIT APPLICATION Permit Type: MECHANICAL FBC 20 Permit No. Master Permit NoA 13 ZE3 JOB ADDRESS: A?P C /D* Q__ City: Miami Shores County: Miami Dade Zip: Foho/Parcel#: 11 ;)4 �0 Is the Building Historically Designated: Yes OWNER: Name (Fee Simple NO _Flood Zone: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Address: OW City: Qualifier Name: %^7 Zip: State Certification or Registration #:Cf?G /r/ 6 Q Contact Phone#: Email Address: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $ * Square/Linear Footage of Work: Type of Work: ❑Address ❑Alteration "'%ONew ORepair/Replace Description i —JVzd VP Submittal Fee $ - Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Notary Radon Fee $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond $ Technology Fee $ TOTAL FEE NOW DUE $ ❑Demolition Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State be zip zip. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Owner or Agent The foregoing instrument was ackn wledged"b"eyfore�^me this 1 day of ' , 20 , by f"�l �l , who is personally known to me r who has produced As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: APPROVED BY Nary Public State of Florida Helsel Alvarez My Commission EE 188011 Signature K;1-1� Vontractor The foregoing instrument was acknowled ed before me this day of , 20 , by ( 4 ' who is personally known to me r who has produced as identification and who did take an oath. Plans Examiner Structural Review Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) NOTARY PUBLIC: Sign: Print: % My Commission Expires: Notary Public Stow of Florida Heise) Alvarez Zoning Clerk FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Residence Remodeling 1 Builder Name: Street: 102 NE 106 St Permit Office: City, State, Zip: Miai Shores, FL, 33138- Permit NOmbqr Owner. Sweetland Real State Asset. LLC moidicti - Design Location: FL, Miami 1. New construction or existing Existing (Projecte 9. Wail Types (2545.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int insuf, Exterior R=5.0 2129.30 ft2 b. Interior Wall, Interior R=5.0 208.00 ft2 3. Number of units, if multiple family 1 c. Interior Wall, Interior R=0.0 208.00 ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. is this a worst case? No 10. Ceiling Types (2400.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 2400.00 fe 6. Conditioned floor area above grade (ft') 2400 b. NIA R= ft' Conditioned floor area below grade (ft2) 0 c. NIA R= fe 11. Duds R ft2 7. Windows(293.1 sqR) Description Area a. Sup: Attic, Ret Main, AH: Main 6 250 a. U -Factor. Sgl, U=0.65 293.06 ft2 b. Sup: Attic, Ret Master Bedroom, AH: Master Be 6 80 SHGC: SHGC--0.35 r b. U -Factor: WA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 57.0 SEERA6.00 b. Central Unit 18.0 SEER:16.00 c. U -Factor. N/A Sa SHGC: 13. Heating systems kBtu/hr Efficiency d. U -Factor N/A ft2 a. Electric Strip Heat 16.4 COPA.00 SHGC: b. Electric Strip Heat 10.2 COPA.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.350 14. Hot water systems a. Electric Cap: 30 gallons 8. Floor Types (2400.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 2400.00 fF b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 15. Credits Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 48.94 PASS Total Standard Reference Loads: 67.79 �7�7 I hereby certify that the plans and specifications covered by Review of the plans and a TIRE STq this calculation are in mpliance with the Florida Energy specifications covered by this indicates Code. ty calculation compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 t � I hereby certify that wilding, designed, i in compliance the Florida Ene Florida Statutes. �C ®b with WE OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires an envelope leakage test report, by a Florida Class 7 Rater, in accordance with Table B-1.1.2. 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 PROJECT Titre: Residence Remodeling 1 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2400 Lot # Owner. Sweetland Real State Asset. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 102 NE 106 St Permit Office: Cross Ventilation: County: Miami -Dade Jurisdiction: Whole House Fan: City, State, Zip: Miai Shores, Family Type: Single-family FL, 33138- New/Existing: Existing (Projected) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating sign Daily Temp Design Location TMY Site Zone 97.6% 2.5% Winter Summer Degree Days Moisture Range FL, Miami Fl - MIAMI INTL AP 1 51 90 70 75 149.5 56 Low BLOCKS Number Name Area Volume 1 Blockl 1900 15200 2 Block2 500 4000 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1900 15200 Yes 4 3 1 Yes Yes Yes 2 Master Bedroom 500 4000 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 254 ft 0 1900 ft' 0 0 1 2 Slab -0n -Grade Edge Insulatio Master Bedroom 106 ft 0 500 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 2473 ft2 300 ft2 Medium 0.21 No 0.9 No 30 14 ATTIC V/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2400 ftz N N 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 CEILING # Ceiling Type Space R -Value Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 1900 ft2 0.11 Wood 2 Under Attic (Vented) Master Bedroom 30 500 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Insul Main 5 53 8 8 429.3 f? 0 0.75 0 2 S Interior Wall Main 26 8 208.0 ft2 0 0 0.75 0 3 S Exterior Concrete Block - Int Insul Main 5 27 8 216.0 ft2 0 0.75 0 4 E Exterior Concrete Block - Int Insul Main 5 39 9 8 318.0 ft2 0 0.75 0 5 W Exterior Concrete Block - Int Insul Main 5 61 9 8 494.0 ft2 0 0.75 0 6 N Interior Wall Master Bedro 5 26 8 208.0 ft2 0 0 0.75 0 7 S Exterior Concrete Block - Int Insldaster Bedro 5 27 8 8 221.3112 0 0.75 0 8 E Exterior Concrete Block - Int InsMaster Bedro 5 34 8 272.0 ft2 0 0.75 0 9 W Exterior Concrete Block - Int InsMaster Bedro 5 22 4 8 178.7 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U Value Width Height Area Ft In Ft In 1 N Wood Main None .46 3 6 8 20 ft2 2 S Wood Main None .46 3 6 8 20 ft2 3 W Wood Main None .46 3 6 8 20 ft2 4 N Wood Master Bedro None .46 3 6 8 20 ft2 5 S Wood Master Bedro None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wali Overhang �/ # Omt ID Frame Panes NFRC U -Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Single (Clear) Yes 0.65 0.35 9.8 ft2 1 It 0 in 1 ft 0 in HERS 2006 None 2 N 1 Metal Single (Clear) Yes 0.65 0.35 12.8 ft2 1 ft 0 in 1 ft 6 in HERS 2006 None 3 N 1 Metal Single (Clear) Yes 0.65 0.35 12.8 ft2 1 ft 0 in 4 ft 0 in HERS 2006 None 4 N 1 Metal Single (Clear) Yes 0.65 0.35 48.6 ft2 1 ft 0 in 1 ft6 in HERS 2006 None 5 S 3 Metal Single (Clear) Yes 0.65 0.35 13.4 ft2 1 ft 0 in 1 ft0 in HERS 2006 None 6 S 3 Metal Single (Clear) Yes 0.65 0.35 8.3 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 7 S 3 Metal Single (Clear) Yes 0.65 0.35 5.0 ft2 1 ft 0 in 5 ft 7 in HERS 2006 None 8 E 4 Metal Single (Clear) Yes 0.65 0.35 12.8 ft2 1 ft 0 in 3 ft 0 in HERS 2006 None 9 E 4 Metal Single (Clear) Yes 0.65 0.35 97.1 ft2 1 ft 0 in 1 ft 6 in HERS 2006 None 10 W 5 Metal Single (Clear) Yes 0.65 0.35 6.7 ft2 1 ft 0 in 1 ft8 in HERS 2006 None 11 W 5 Metal Single (Clear) Yes 0.65 0.35 33.3 ft2 1 ft 0 in 1 ft 8 in HERS 2006 None 12 S 7 Metal Single (Clear) Yes 0.65 0.35 19.5 ft2 1 It 0 in 1 ft 8 in HERS 2006 None 13 E 8 Metal Single (Clear) Yes 0.65 0.35 12.8 111:2 1 ft 0 in 1 ft8 in HERS 2006 None 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed SLA .0003 1888.6 103.68 194.99 .207 5.9018 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Strip Heat Electric Strip Heat None None COP: 1 16.38 kBtu/hr COP: 1 10.24 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 2 Central Unit Central Unit None None SEER: 16 57 kBtu/hr 1710 cfm 0.75 SEER: 16 18 kBtu/hr 540 dm 0.75 1 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.92 30 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None f12 DUCTS / 1/ # — Supply — Location R-Value Area --- Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 250 ft2 Attic 6 80 ft2 Main 1 ft2 Default Leakage Main (Default) (Default) Master Bedro 1 ft2 Default Leakage Master Bed (Default) (Default) 1 1 2 2 TEMPERATURES Programable Thermostat: Y Cooling Jan Feb Mar Venting Jan Feb Mar Ceiling Fans: Apr ]MayJun Jul rl AugSep W Oct Apr May Jun Jul Aug Sep OctO Nov X Nov Dec HDec 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 Hours 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/11/2013 3:56 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 102 NE 106 St PERMIT* Miai Shores, FL, 33138 - MANDATORY REQUIREMENTS SUMMARY - See Individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Duds 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and a sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special x equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 12/11/2013 3:56 PRO EnergyGauge@ USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 72 The lower the EnergyPerformance Index, the more efficient the home. 102 NE 106 St, Miai Shores, FL, 33138- 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftp 7. Windows*" Description a. U -Factor. Sgl, U=0.65 SHGC: SHGC--0.35 b. U -Factor. N/A SHGC: c. U -Factor. N/A SHGC: d. U -Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: Existing (Projects 9. Wall Types Insulation Single-family a. Concrete Block - Int Insul, Exterior R=5.0 b. Interior Wall, Interior R=5.0 1 c. Interior Wall, Interior R=0.0 3 d. N/A R= 10. Carling Types Insulation No a. Under Attic (Vented) R=30.0 2400 b. N/A R= Area c. N/A R= 293.06 ft' 11. Duds a. Sup: Attic, Ret: Main, AH: Main b. Sup: Attic, Ret: Master Bedroom, AH: Master Be fe 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ftz 161 1.000 ft 0.350 Area 2400.00 ft' fta ftz 12. Cooling systems a. Central Unit b. Central Unit 13. Heating systems a. Electric Strip Heat b. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Area 2129.30 ft2 208.00 fe 208.00 ftp fta Area 2400.00 ftp fl? ftz R ftz 6 250 6 80 kBtu/hr Efficiency 57.0 SEER:16.00 18.0 SEER:16.00 kBtu/hr Efficiency 16.4 COP:1.00 10.2 COP:1.00 Cap: 30 gallons EF: 0.92 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software • • • 12111/2013 3:57 PM EnergyGauge@ / USRFZB v3.1 Page 1 of 6 PROJECT Title: Residence Remodeling 1 Bedrooms: 3 Address Type: Street Address Building Type: User Bathrooms: 0 Lot # Owner. Sweetland Real State Asset. Conditioned Area: 2400 sq.ft. BlocldSubDivision: # of Units: 1 Total Stories: 1 PlatBook: Builder Name: Worst Case: No Street: 102 NE 106 St Permit Office: Rotate Angle: 0 County: Miami -Dade Jurisdiction: Cross Ventilation: City, State, Zip: Mial Shores, Family Type: Single-family Whole House Fan: FL, 33138- 313&New/Existing: New/Existing: Existing (Projected) Terrain: Suburban Year Construct 1960 Shielding: Suburban Comment CLIMATE Design Design Temp Int Design Temp Heating Design Daily Temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Miami FL MIAMI INTL AP 51 90 70 75 149.5 56 LOW UTILITY RATES Fuel Unit Utility Name Monthly Fused Cost $/Unit Electricity kWh Florida Average 0 0.1151 Natural Gas Therm Florida Average 0 1.72 Fuel Oil Gallon Florida Default 0 1.1 Propane Gallon Florida Default 0 1.4 SURROUNDINGS Shade Trees Adjacent Buildings Omt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW Norte Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft BLOCKS Number Name Area Volume 1 Blocic1 1900 15200 2 Blodc2 500 4000 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated 1 Main 1900 15200 Yes 4 3 Yes Yes Yes 2 Master Bedroom 500 4000 No 0 0 Yes Yes Yes 12111/2013 3:57 PM EnergyGauge@ / USRFZB v3.1 Page 1 of 6 Building Input Summary Report 12/11/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 2 of 6 FLOORS # Floor Type Space Perimeter Perimeter R -Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation Main 254 ft 0 1900 ft2 0 0 1 2 Slab -On -Grade Edge Insulation Master Bedroom 106 ft 0 500 ft2 _ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 2473 ft2 300 ft2 Medium 0.21 No 0.9 No 30 14 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2400 ft2 N N CEILING # Ceiling Type Space R -Value Area Framing Fraction Truss Type 1 Under Attic Q Main 30 1900 ft2 0.11 Wood 2 Under Attic Q Master Bedroom 30 500 ft2 0.11 Wood WALLS Wali orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. Adiacent S�� Cavity Width Her'ght Sheathing Framing Solar Below # Omt o Wall Type R -Value Ft In Ft In Area R -Value Fraction Absor. Grade% 1 N Exterior Concrete Block - Int Insul Main 5 53 8 8 429.3 ft2 0 0.75 0 2 S Interior Wall Main 26 8 208.0 ft2 0 0 0.75 0 3 S Exterior Concrete Block - Int Insul Main 5 27 8 216.0 ft2 0 0.75 0 4 E Exterior Concrete Block - Int Insul Main 5 39 9 8 318.0 ft2 0 0.75 0 5 W Exterior Concrete Block - Int Insul Main 5 61 9 8 494.0 ft2 0 0.75 0 6 N Interior Wail Master Bedro 5 26 8 208.0 ft2 0 0 0.75 0 7 S Exterior Concrete Block - Int Insulllaster Bedro 5 27 8 8 221.3 ft2 0 0.75 0 8 E Exterior Concrete Block - Int InsLiMaster Bedro 5 34 8 272.0 ft2 0 0.75 0 9 W Exterior Concrete Block - Int InsuMaster Bedro 5 22 4 8 178.7 ft2 0 0.75 0 DOORS Width Height # Omt Door Type Space Storms U -Value Ft in Ft In Area 1 N Wood Main None .46 3 6 8 20 ft2 2 S Wood Main None .46 3 6 8 20 ft2 3 W Wood Main None .46 3 6 8 20 ft2 4 N Wood Master Bedro None .46 3 6 8 20 ft2 5 S Wood Master Bedro None .46 3 6 8 20 ft2 12/11/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 2 of 6 12/11/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 3 of 6 WINDOWS Wall Overhang # Omt ID Frame Panes NFRC U -Factor SHGC Storm Area Depth Separation Interior Shade Screening 1 N 1 Metal Single (Clear) Yes 0.65 0.35 N 9.8 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 2 N 1 Metal Single (Clear) Yes 0.65 0.35 N 12.8 ft2 1 ft 0 in 1 ft 6 in HERS 2006 None 3 N 1 Metal Single (Clear) Yes 0.65 0.35 N 12.8 ft2 1 ft 0 in 4 ft 0 in HERS 2006 None 4 N 1 Metal Single (Clear) Yes 0.65 0.35 N 48.6 ft2 1 ft 0 in 1 ft 6 in HERS 2006 None 5 S 3 Metal Single (Clear) Yes 0.65 0.35 N 13.4 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 6 S 3 Metal Single (Clear) Yes 0.65 0.35 N 8.3 ft2 1 ft 0 in 1 ft 0 in HERS 2006 None 7 S 3 Metal Single (Clear) Yes 0.65 0.35 N 5.0 ft2 1 ft 0 in 5 ft 7 in HERS 2006 None 8 E 4 Metal Single (Clear) Yes 0.65 0.35 N 12.8 ft2 1 ft 0 in 3 ft 0 in HERS 2006 None 9 E 4 Metal Single (Clear) Yes 0.65 0.35 N 97.1 ft2 1 ft 0 in 1 ft 6 in HERS 2006 None 10 W 5 Metal Single (Clear) Yes 0.65 0.35 N 6.7 ft2 1 ft 0 in 1 ft 8 in HERS 2006 None 11 W 5 Metal Single (Clear) Yes 0.65 0.35 N 33.3 ft2 1 ft 0 in 1 ft 8 in HERS 2006 None 12 S 7 Metal Single (Clear) Yes 0.65 0.35 N 19.5 ft2 1 ft 0 in 1 ft 8 in HERS 2006 None 13 E 8 Metal Single (Clear) Yes 0.65 0.35 N 12.8 ft2 1 ft 0 in 1 ft 8 in HERS 2006 None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 Space(s) 1 Wholehouse Proposed SLA .0003 1888.6 103.68 194.99 .207 5.9018 All MASS Mass Type Area Thickness Furniture Fraction Space No Added Mass 0 ft2 Oft 0.3 Main No Added Mass 0 fie Oft 0.3 Master Bedroom HEATING SYSTEM # System Type Subtype Efficiency Capacity Ducts Block 1 Electric Strip Heat None COP:1 16.38 kBtu/hr sys#1 1 2 Electric Strip Heat None COP:1 10.24 kBtu/hr sys#2 2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Duds Block 1 Central Unit None SEER:16 57 kBtu/hr 1710 cfm 0.75 sys#1 1 2 Central Unit None SEER:16 18 kBtu/hr 540 cfrn 0.75 s s#2 2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Credits 1 Electric None Main 0.92 30 gal 60 al 120 deg None 12/11/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 3 of 6 Building Input Summary Report 12/11/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 4 of 6 SOLAR HOT WATER Collector Surface Absorp. Trans Tank Tank Tank Heat PV Pump Collector Type Tilt Azimuth Area Loss Coef. Prod. Corr. Volume U -Value Surf Area Exch Eff Pumped Energy DUCTS DUCT Supply Return Air CFM 25 CFM25 HVAC # # Location R -Value Area Location Area Number Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic 6 250 W Main 1 fie Default Leakage Main (Default) (Default) 1 1 2 Attic 6 80 fta Master Bedro 1 ft2 Default Leakage Master Bed Default(Default) 2 2 TEMPERATURES Programabl[e hermosta[[t��Y Ceiling Fans: [IC] Jan [X] Feeb WMar W nN Jun Jul riHeating Aug ri SOP W Oct O Nov No H Doc Venting [[ ]] Jan [[ ]) Feb Mar Apr MY Jun Jul Aug Sep X DDeecc Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) 68 68 68 6688 68 6666 PPM 68 68 6688 68 6668 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/11/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 4 of 6 11111111111111 111111111Iq 12111/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 5 of 6 APPLIANCES & LIGHTING Appliance Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Ceiling Fans (Summer) AM 0.65 0.65 0.65 0.65 0.65 0.65 0.65 0.33 0.33 0.33 0.33 0.33 % Released: 100 PM 0.33 0.33 0.33 0.33 0.33 1 0.9 0.9 0.9 0.9 0.9 0.65 Annual Use: 0 kW1VYr Peak Value: 0 Watts Clothes Washer AM 0.105 0.081 0.046 0.046 0.081 0.128 0.256 0.57 0.849 1 0.977 0.872 % Released: 60 PM 0.779 0.698 0.605 0.57 0.581 0.57 0.57 0.57 0.57 0.488 0.43 0.198 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dishwasher AM 0.139 0.05 0.028 0.024 0.029 0.09 0.169 0.303 0.541 0.594 0.502 0.443 % Released: 60 PM 0.377 0.396 0.335 0.323 0.344 0.448 0.791 1 0.8 0.597 0.383 0.281 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Dryer AM 0.2 0.1 0.05 0.05 0.05 0.075 0.2 0.375 0.5 0.8 0.95 1 % Released: 10 PM 0.875 0.85 0.8 0.625 0.625 0.6 0.575 0.55 0.625 0.7 0.65 0.375 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Lighting AM 0.16 0.15 0.16 0.18 0.23 0.45 0.4 0.26 0.19 0.16 0.12 0.11 % Released: 90 PM 0.16 0.17 0.25 0.27 0.34 0.55 0.55 0.88 1 0.86 0.51 0.28 Annual Use: 2375 kWh/Yr Peak Value: 776 Watts Miscellaneous AM 0.48 0.47 0.47 0.47 0.47 0.47 0.64 0.71 0.67 0.61 0.55 0.53 % Released: 90 PM 0.52 0.5 0.5 0.5 0.59 0.73 0.79 0.99 1 0.96 0.77 0.55 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Pool Pump AM 0 0 0 0 0 0 0 0 0 1 1 1 % Released: 0 PM 1 1 1 1 0 0 0 0 0 0 0 0 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Range AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.4 % Released: 100 PM 0.457 0.343 0.286 0.4 0.571 1 0.857 0.429 0.286 0.229 0.171 0.114 Annual Use: 0 kWh/Yr Peak Value: 0 Watts Refrigeration AM 0.85 0.78 0.75 0.73 0.73 0.73 0.75 0.75 0.8 0.8 0.8 0.8 % Released: 100 PM 0.88 0.85 0.85 0.83 0.88 0.95 1 0.98 0.95 0.93 0.9 0.85 Annual Use: 775 kWh/Yr Peak Value: 140 Watts Well Pump AM 0.05 0.05 0.05 0.05 0.05 0.05 0.1 0.1 0.1 0.1 0.1 0.1 % Released: 0 PM 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Annual Use: 0 kWh/Yr Peak Value: 0 Watts REFRIGERATORS ID Type Screen Location Quantity Vol FrZ. Vol Make Model Schedule kWhPerYr 1 Default New Main 1 CLOTHES WASHERS ID Type Screen Location Capacity Make Model Schedule LoadsPerYr 1 1 Main Default New Main 2.847 (invalid) 2 2 Main Default Existing Main 2.847 (invalid) 3 3 Main Default Existing Main 2.847 (invalid) 12111/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 5 of 6 Building Input Summary Report 12111/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 6 of 6 CLOTHES DRYERS ID Type Screen Location Capacity Fuei Type Make Model Schedule LoadsPerYr 1 Dryers Default Now Main Electricity DISHWASHERS ID Type Screen Location Capacity Vintage Make Model Schedule kWhPerYr 1 Dishwash Default New Main RANGE OVEN 1D Type Screen Location Type Fueltype Make Model Cooktop Oven 1 Ranges Default New Main CooktopOven C Electricity HARD WIRED LIGHTING ID Type Screen Location Quantity Comp FI All Other FL txtBulbtype Schedule Watts per bulb 1 2 Default Default 1st Floor Exterior AMSC ELECTRICAL LOADS ID Type Screen Item Quantity Catagory Operating Location Schedule Off Standby 1 Misc Elec Simple Default 1 1 Main HERS201 1 12111/2013 3:57 PM EnergyGauge® / USRFZB v3.1 Page 6 of 6 Residential System Sizing Calculation Summary Sweetland Real State Asset. LLC Project Title: 102 NE 106 St Residence Remodeling 1 Miai Shores, FL 33138- 12/11/2013 Location for weather data: Miami, FL - Defaults: Latitude(25.82) Altitude(? ft.) Temp Range(L) Humidity data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 58 r. 293 sqft Winter design temperature(MJ8 99%) 50 F Summer design temperature(MJ8 99%) 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 20 F Summer temperature difference 15 F Total heating load calculation 24499 Btuh Total cooling load calculation 69157 Btuh Submitted heating capacity % of Calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Strip Heat) 108.6 26613 Sensible (SHR = 0.75) 87.2 56250 24499 Btuh Ventilation Latent 402.4 18750 Btuh TOTAL HEAT LOSS Blower Load Total 108.4 75000 WINTER CALCULATIONS Winter Heatina Load (for 2400 soft Load component Load Window total 293 sqft 3810 Btuh Wall total 2152 sqft 4621 Btuh Door total 100 sqft 920 Btuh Ceiling total 2400 sqft 822 Btuh Floor total See detail report 8496 Btuh Infiltration 106 cfm 2331 Btuh Duct loss Internal gain 3499 Btuh Subtotal Duct gain 24499 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS Blower Load 24499 Btuh Summer rnnlinn 1 narl (fnr 94nn snft) 1"r, _�»F, SUMMER CALCULATIONS Load component Load Window total 293 sqft 6551 Btuh Wall total 2152 sqft 3466 Btuh Door total 100 sqft 1380 Btuh Ceiling total 2400 sqft 1808 Btuh Floor total 0 Btuh Infiltration 79 cfm 1311 Btuh Internal gain 47120 Btuh Duct gain 2861 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 64498 Btuh Latent gain(ducts) 725 Btuh Latent gain(infiltration) 3134 Btuh Latent gain(ventilation) 0 Btuh Latent gain(internaVoccupants/other) 800 Btuh Total latent gain 4660 Btuh TOTAL HEAT GAIN 69157 Btuh lt�r*tir 11RfWt�,1 1 x-'n•inin. (I4,) 11 iinrw; =O.u) W amc(19%) WInJowsf9'%) inpst3%) Ucors(1'}o) nurte(;44o EnergyGauge® System Sizing PREPARED BY: DATE: EnergyGauge® / USRFZB v3.1 Y ROCHELL ENGINt=ANG, INC. January 16, 2014 Mr. Ismael Naranjo, Building Official Miami Shores Village Building Dept. 10050 N.E. 2nd Avenue Miami Shores, Florida 33138 Re: Sweetland Residence Remodeling 102 N.E. 106th Street Miami Shores, FL 33138 Permit Number: RC13-2849 Dear Building Official, The present letter is to notify to the concerned parties and corresponding authorities that I, Alexander Rochell, P.E., has visited the existing residential structure and has performed an inspection of the structural envelope, which includes the floor framing. The floor framing consists of 2x10 wood joists spanning between exterior masonry walls and interior stem walls. The floor sheathing consists of 5/8" thick plywood sheathing nailed to the wood joists in an uniform pattern. No visible deterioration could be observed on the wood floor framing during this inspection. The wood floor framing for this residence is functioning and in good condition. There are no obvious overloading or overstress signs of the structural members or significant deterioration of the structure. The effect of time with respect to deterioration of the original construction materials has been evaluated and is considered minimal. Should you have any question regarding the above, please do not hesitate to contact our office. Respectfully, Alexander R66hell, P.E. Florida Professional Engineer Registration No. 60235 205 Santillane Avenue, Coral Gables, FL 33134 Tel 305.649.4049 Fax: 305.649.4149