Loading...
WS-14-1750Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-217670 Scheduled Inspection Date: November 05, 2014 Inspector: Rodriguez, Jorge Owner: , BARRY UNIVERSITY Job Address: 11300 NE 2 Avenue Adrian Hall Miami Shores, FL 33138-0000 Project: BARRY UNIVERSITY Contractor: J NEWTON ENTERPRISES INC t3unamg Department comments REPLACE DOORS AT MECHANICAL ROOM Permit Number: WS -8-14-1750 Permit Type: Windows/Shutters Inspection Type: Final Work Classification: Door Replacement Phone Number Parcel. Number 1121360010160-07 INSPECTOR COMMENTS False Phone: (877)317-5854 Passed Inspector Comments Failed Correction Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. November 04, 2014 For Inspections please call: (305)762-4949 Page 8 of 31 I,_kl BUILDING RECEIVED .Miami Shores Village AUG 112014 Building Department BY: 10050 NX.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 7954204 Fax: (305) 786-8972 INSPECTION LINE PHONE NUMBER: (305) 7.62-4949 FBC 20 1 (3 Master Permit No. Lkj S J 4 -A-1 S PERMIT APPLICATION I Sub Permit No, 21ruILDING [ ELECTRIC M ROOFING � REVISION F-1 EXTENSION F] RENEWAL MPLUMBING E]MECHANICAL FIPUBLIC WORKS r7 CHANGE OF r_]CANCELLATION E3 SHOP CONTRACTOR DRAWINGS Folio/Parcel#: I I - -=-.00'50 is the Building Historically Designated: Yes _ NO — Occupancy Type: _ Load: - Construction Type: Flood Zone: BFE. FFE:_ City: t-v-ar. %V -'O{ es State: tzip: Zink i,& Tenant/Lessee Name: Phone# - Email: --" CONTRACTOR: Company Name- Phone#- U I Address: City: Qualifier Name: L61*1t - etis- ��%�4 Phone#. . (�o— State Certification or Registration #: 't)C- C I Q 41'S Certificate of Competency * DESIGNER: Architect/Engineer: ��C;L)2�e ykrA_Y%rl�CNk Phone#:. '5H-4UQ-55_1,3 Address: 0 n! City: 1_04A4L_y�Ite:. 'PL zip: 3333()a Value of Work for this Permit-, $ Square/Linear Footage -of Work: Type of Work: El Addition D Alteration 0 New Rlkepair/Replace El Demolition Description of Work., �k t)\'ac lenc:frry DC7 CAYV' _ Ck V-'e'y' C� IST H[A W I CA --ICOM Specify color of color thru We; " -I Submittal Fee $ �15 0 Permit Fee $ CCF $ CO/CC Scanning Fee $ Radon Fee $ DBPR $ Notary Technology Fee $ Training/Education Fee Double Fee $ Structural Reviews Bond $ TOTAL FEE NOW DUE $ CQ (Revised02/24/2014) 0 a Bonding Company's Name (if applicable) Bonding Company's Address City State Zip Mortgage Lender's Name (1fapplicable) Mortgage Leader's Address city State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the lssuance of a permit and that all work will be performed to meet the standards of all laws regulating construction In this Jurisdiction. I understand that a separate permit must be=:secured for ELECTRIC, PLUMBIN.a,.SIGNS, POOLS, FURNACES, BOILERS; HEATERS, TAW) AIR CONDITIONERS; ETC..... OWNER'S AFFIDAVIT. I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance oft:building building permit with an estimated value exceeding S2500, the applicant must promise In good faith that a copy of the notice of commencement and construction lien law brochure will be dell * ered to the person whose property. ii subject to attachment. Also, a certified copy of the recorded &tice of commencement must be: posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the Inspection will not be approved and o reinspection fed, will be charged. /J OWNER or AGENT The oregoing instrument was acknowledged before me this day of QQ-<b . 21i �4 , by 'W54N q.S t!VkA(,-, whoispersonally known to CONTRACTOR The foregoing, instrument was _acknowledged beforee me this day of 20 _ i 9 by I—(� C • e who is personally known to me or who has produced as me or who has produced as identification and who did take an oath. NOTARY PU"C 1-11 Print: L Seal: JEFFRY J. yr A, MY COMMISSION# X0.0 EXPMES: Novanbea 12, -} IAMO-3-NOTARY Fl. Natwy DWOnt AM= CO. IP1� #Nr�N�kakt� kkMeoleN.q¢ak-9t.k8oekA.'d+S>aA�*?k+k�R3k+klRkaM?k!R APPROVED BY (Revised 02/24/2014): Identification and who did take an oath. NOTARY PUBLIC: Plans Examiner Structural Review raras�'�`.:Tjlw Zoning Clerk CO ARD . CERTIFICATE OF LIABILITY INSURANCE DAT 8/11/2014 8111=14 PRODUCER Phone - 954 583-5444 Fax - 954-583-2820 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE Pelican Insurance Agency HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND, OR g y ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW 100 NW 70th Ste 203 INSURERS AFFORDING COVERAGE NAIC # Plantation, FL 33317 INSURERA: Endurance American Specialty INCImr-in J Newton Enterprises Inc. INSURER B: Mt Hawley INSURER c: BridgeField 755 S. Little John Ave. INSURER D: Inverness, FL 34450 INSURER E: COVERAGES THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED, NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES, LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTPOLICY R TYPE OF INSURANCE POLICY NUMBER DTYY) E (MM/DD/DATE (MM/DD/YY)N LIMITS A GENERAL LIABILITY EACH OCCURENCE $ 1,000,000.00 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED $ 100,000.00 CLAIMS MADE ®OCCUR MED EXP (Any one person) $ 5000 CBC10001146502 7/21/2014 7/21/2015 PERSONAL BADV INJURY $ 1,000,000.00 GENERAL AGGREGATE $ 2,000,000.00 GEML AGGREGATE LIMIT APPLIES PER: PRODUCTS -COMP/OP AGG $ $2,000,000.00 POLICY X JECT LOC AUTOMOTIVE LIABILITY ANY AUTO COMBINED SINGLE LIMIT (Ea accident) $ BODILY INJURY $ (Per person) ALL OWNED AUTOS SCHEDULED AUTOS BODILY INJURY $ (Per acdclent) HIRED AUTOS NON -OWNED AUTOS PROPERTY DAMAGE $ (Per accident) GARAGE LIABILITY AUTO ONLY - EA ACCIDENT $ ANY AUTO X OTHER THAN EA ACC $ ALTO ONLY: AGG B EXCESS LIABILITY EACH OCCURENCE $ 2,000,000.00 AGGREGATE $ 2,000,000.00 X OCCUR CLAIMS MADE EMX0319323 7/21/2014 7/21/2015 $ DEDUCTIBLE $ $ RETENTION $ C WORKER'S COMPENSATION AND EMPLOYERS' LIABILITY ANY PROPRIETOR/PARTNER/EXECUTIVE OFFICER/MEMBER EXCLUDED? If yes, describe under SPECIAL PROVISIONS below 830-53785 7/29/2014 7/29/2015 ® O H- TORY LIMITS R E.L. EACH ACCIDENT $ 1,000,000.00 E.L. DISEASE - EA EMPLOYEE $ 1,000,000.00 E.L. DISEASE -POLICY LIMIT $ 1,000,000.00 c OTHER Excess Liability DESCRIPTION OF OPERATIONS/LOCATIONSIVEHICLES/EXCLUSIONS ADDED BY ENDORSEMENT/SPECIAL PROVISIONS Miami Shores Village Building Departmen Is listed as additional Insured. License # SCC131151295 CERTIFICATE HOLDER Ix DDmONAL INSURED; INSURER LETTER: A CANCELLATION See Below - Miami Shores Village Building Department 10050 NE 2 Ave Miami Shores, FL 33138 SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE TTHEREOFd THE THE CERTIFICATE HOLDMPANY RENAMED TO THEENDEAVORO NEIL EXPIRATION DAT UING 10 DA S WRITTEN NOTICE —WIT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE COMPANY, ITS AGENTS OR REPRESENTATIVES. , AUTHORIZED REPRESENTATIVE r Samuel Jacks-- W ACORD 26 (2001/08) 1 of 2 QACORD CORPORATION 1988 FLOOR P LAN J Newton Enterprises, Inc. ...... ... 4090 SW 30th Avenue .•.•: .: Fort Lauderdale, FL 33312 :.:.:•:: :.:. .... W .. .. .. . ..... ..... .... i %: S O ~Q C0 m .... U_j < . .. ... .. z o 0 w0- oLU c 2 . ..... . %* .. .. . ....... Barry University 11300 NE 2nd Avenue Miami Shores, FL 33161 ADRIAN MECHANICAL ROOM FBC #AD12-16 DESIGN PRESSURE: 53 LB/FT2 -HEADER N W4 E S W Li LjQ i S O ~Q C0 m U_j < z o 0 w0- oLU c 2 Barry University 11300 NE 2nd Avenue Miami Shores, FL 33161 ADRIAN MECHANICAL ROOM FBC #AD12-16 DESIGN PRESSURE: 53 LB/FT2 -HEADER N W4 E S WIND LOAD CALCULATIONS Property: Barry University 11300 NE 2nd Ave. Miami, FL 33161 Type of work: Adrian Mechanical Room replacement of two pair 18ga steel doors on first floor.. Basic wind speed: Exposure C, h< 15ft, for Dade County V = 170mph. Design pressure loading: Use ASCE 7-10: qZ = 0.00256 KZKAV2 Where: Kz = 0.85 K7t=1.0 Kd = 0.85 V= 170mph qZ = (0.00256)(0.85)(1.0)(0.85)(170)2 =,43 lb/ft2 By: l Date: D ancock, P.E. • • • FL# 17501 0 0 0 •••• 0000.. •• • 0000.. 0000 0000 0000.. 0000 0000.. 0000.. 0000.. 000000 0000 0008 0000.. 0000.. 0000.. 0000. •...• .000.0 :0*00: 000000 9110 SW SUNSET DRIVE MCY ENGINEERING, INC. MIAMI, P: 305-271-0117 GLAZING CONSUL l'ANT CAN #28577 PRODUCT APPROVAL EVALUATION Date: 0412412012 Detailed Product Description: Manufacturer: Masker Door, Inc Model Name: "N" Series Commercial Steel Doors Outswing Maximum Frame Width: 10050 This Product complies with Maximum Frame Height: S8" the High Velocity Maximum Load: +175 - f a e Missile Imact Hurricane Zone (HVH2) P � testing requirements. Reference Drawings # AD12•-16 _ The above maximum parameters may not occur simultaneously. Refer to installation drawings for design. loads Mandatory Tests (Tested In accordance with AAMA 10111.S.21NAFS-021TAS-202) TEST ; : `. ";, DSCF�TiON ., , f. ' ` ::TEST LOCATION: :" :. :.: TEST' . ... ;. , n ST REP 0 4 CtATE REPORT # ASTM E283-02 Air Infiltration Testing Evaluation Leakage Laboratories, Inc. ASTM E331-00 Water Testing Evaluation OR ASTM 547- Penetration Laboratories, Inc. 00 & TAS 202 ASTM E330-02 Uniform Static Testing Evaluation June 30,2008 TEL -0'1280089 & TAS 202 Air Press, Laboratories, Inc. June 30,2008 TEL -01280070 AAMA"i 302.5- Forced Entry Testing Evaluation 70 & 1303.5-76 Laboratories, Inc. Comparative Analysis used`Yes _c No: As per guidelines for HAVHZ for Dade County. Supplemental Tests (Tested In accordance with TAS -203) • • • • • • .; TIE=ST:.;:; :. ::_0000 , .. .;.. ; pESC�ttF�TIi�P�::: }':;: "': .iiVST .r.. ,. L O�ATI� � 0000 N'�` ?::= ; TEST - TE T • FBC 1626.2 Testing Evaluation (TAS201&203) Large Missile Laboratories, Inc. • • •• ..TEL- • 01280069 ASTM E1886 Impact & Cyclic June 30,2008:::10 TEL-01?,]lT1ti' ASTM E1996-02 June 30,2008 0 Under the limitations of the attached drawings, to the best of my knowledge and ability, the above winig;Wdoor product conforms to the requirements of the 2007! 2010 Florida Bui4.36"t?', • Evaluation Report Engineer: eee �� •°•..°•VYAVG'V ••• • Yping Wang PE # 55983 �� ��.•''�5°°° `�� MCY ENGINEERING EB # 28677 7 r4o 7 gull STA't-S of eo ° e j � 000000 000000 .0000. 00000 . i 00000 0.6000 6 0 , .6666. (4) ANCHORS FOR DESIGN LOADS _ S75 PSI (2) ANCHORS FOR DESIGN LOADS 537.5 PSI S2 x z z a 4710 100" 4 1041/2" 4 1/2" IFKUM t:NUJ —4- 0 wu +F / SPACING AT JAMB REDUCED TO 12" O.C. \--(4) ANCHORS FOR DESIGN WHEN ANCHOR INTO BLOCK & LOADS 575 PSI LOAD>37.5 PSF (2) ANCHORS FOR DESIGN LOADS 537.5 PSI D0UB6EDG0R TYP•ELEVATION 0wu 8cc . • . • • _ . \ 8 1 Table of contents and test elevation 2 \ 3 \ 4 Horizontal Cross • PQSR7I+F WATM \ d \ 7 \ 8 comporrorrts N WALL DRESSING OR STUCCO. 'v X —I / TO SILL IS LESS THAN 45 DEGREES. • MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS � N THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS. / f IMPOSED BY DOOR SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. o / SPACING AT JAMB REDUCED TO 12" O.C. \--(4) ANCHORS FOR DESIGN WHEN ANCHOR INTO BLOCK & LOADS 575 PSI LOAD>37.5 PSF (2) ANCHORS FOR DESIGN LOADS 537.5 PSI D0UB6EDG0R TYP•ELEVATION ••• • • • • ••• • • • • • • • • • • • • • •• ••• • •• • •• •• ••• • ••• • • 0wu 8cc . • . • • _ . y z 8 1 Table of contents and test elevation 2 Door panel defulls 3 Hcdmntal and vBrffcd wcuon 4 Horizontal Cross • PQSR7I+F WATM • DOORS RATED FOR LARGE MISSILE IMPACT AND DO NOT REQUIRE d SHUTTERS. 7 . 8 comporrorrts ••• • • • • ••• • • • • • • • • • • • • • •• ••• • •• • •• •• ••• • ••• • • I OF B "N" SERIES COMMERCIAL OUTSWING STEEL DOOR (LMB y z 8 w • THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE `6 REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING HIGH LL VELOCITY HURRICANE ZONE (HVHZ). ago*=M • DOOR NOT MEET THE WATER INFILTRATION REQUIREMENTS FOR THE PQSR7I+F WATM • DOORS RATED FOR LARGE MISSILE IMPACT AND DO NOT REQUIRE w SHUTTERS. • ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON ELEVATIONS / w DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND N WALL DRESSING OR STUCCO. 'v • ANCHORING OR LOADING CONDITIONS NOT SHOWN IN THESE DETAILS 0� ARE NOT PART OF THIS APPROVAL. TO SILL IS LESS THAN 45 DEGREES. • MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS � N THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS. • METAL STRUCTURES NOT BY MESKER INC. MUST SUPPORT LOADS f IMPOSED BY DOOR SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. I OF B • DOOR PANEL: MIN. 16 GA. (0.060" THK.) STEEL MIN. Fy = 40.3 KSI MIN. 8 Fk4W DOOR FRAME: MIN. 16 GA. (0.060"THK.) STEEL e ago*=M • DOOR NOT MEET THE WATER INFILTRATION REQUIREMENTS FOR THE PQSR7I+F WATM z g::1 w "HVHZ" AND SHALL BE INSTALLED ONLY IN NON -HABITABLE AREAS OR R w HABITABLE LOCATIONS PROTECTED BY AN OVERHANG OR CANOPY NO YES a # V 'v SUCH THAT THE ANGLE BETWEEN THE EDGE OF CANOPY OR OVERHANG 0� ' m TO SILL IS LESS THAN 45 DEGREES. �' LL NOTES: f EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL. o I OF B ovrnee smkc Fk4W 11kaArka~ssur:r ago*=M PQSR7I+F WATM • No 4 / 100A0" x 98.00" YES Yes +75.0 -75.0 100.0o"x96.0(" NO YES +37.5 -37.5 ®,,o;�•: °yes Sc� v I OF B 0 P os f� 4.5° �I i 45.38" MAX. PANEL HEIGHT 19 g "M SERIES COMMERCIAL OUTSWING STEEL DOOR (L.M.I.) MCY ENGINEERING, INC. MESIO=R DOOR INC. GLAZING CONSu-TANTS C 7�t 3440 STANDVMD BLV. 8501 SW 124L6 ST STE.206 A P. 306.271.0117 m W c P. (25a) 886870 F: (BW)B03.1410 AL 35811MtAWF- 33183 P. 788.673.6083 TYPICAL ANCHORS @HEAD/JAMB: (REFER TO ELEVATION FOR SPACING) TYPE A 3/8' DIA. DYNABOLT SLEEVE ANCHOR SY 971` O DIRECTLY INTO fW=3000 PSI CONCRETE, 1-12" MIN. EMBED DIRECTLY INTO GROUT FILLED CONCRETE BLOCK, 1-12' MIN. EMBED MIN. EDGE DIST 242' MIN. SPACING 4-12' TYPE 8 3/8" TAPPER BY POWERS ® DIRECTLY INTO fB=3000 PSI CONCRETE, 1-12" MIN. EMBED DIRECTLY INTO GROUT FILLED/HOLLOW CONCRETE BLOCK, 1-14" MIN. EMBED MIN. EDGE DIST 3-12" MIN. SPACING 4-12" TYPE C 5/18" DIA SMS OR MACHINE BOLTS (MIN. GRADE 5 CRS) OR BUST O STEEL: Fy= 38 KSI MIN. INTO METAL STRUCTURES (STEEL OR ALUMINUM 1/8" MIN. THICK) ALUMINUM: 8083.78 MIN. (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL ANCHORS 0- THRESHOLD: (REFER TO ELEVATION FOR SPACING) TYPE D 1/4" TAPCON BY "ITW DIRECTLY INTO 18=3000 PSI CONCRETE O 1-1/4" MIN. EMBED MIN. EDGE DIST 2-12" MIN. SPACING 3" SEALANT. ALL FRAME JOINTS AND CORNERS TO BE SEALED WITH SILICONE AT PERIMETER N 5/18" TEKS INTO ST. 1/8" THK MIN FOR SPACING REFER TO ELEVATION IK •• ••• • • • •' • • • • • • • • • • O"RIO� EXTERIOR INTERIOR 3 VER1 M CROSS SWRON 3 EXTERIOR INTERIOR R 2 ANCHOR OP • I • • • • • • • • • • •Z HORIZONTAL CROSS SECTION 4 • • • • 0 see • •• •• •• .... ....... . . ..... . ... . ...... . .... .... . . .... . t3o 4 VERTICAL CROSS EMN 3 f'' zev H Z -16 II 3 OF 11 �l 0 m gg tl -W SERIES COMMERCIAL OUTSWINO STEEL DOOR (LM.I.) MCY ENGINEERING. INC. NEnaroxs o C MESIER DOOR INC. OUIZINO CONSULTANTS ^ ND ATE Di9CRd'T[ON m 1U� 6 34408TH LLF A D BLVD. 8501 SW 124th FL 33163 T 3TE206 A � HUNT86.673.6083 l' 801 80670 F. (800503 -1410 :0000: 00608, 0 so (44 � so : 00 04 -- 000:00 sees* *so 00 00 0069 000000 11 �l 0 m gg tl -W SERIES COMMERCIAL OUTSWINO STEEL DOOR (LM.I.) MCY ENGINEERING. INC. NEnaroxs o C MESIER DOOR INC. OUIZINO CONSULTANTS ^ ND ATE Di9CRd'T[ON m 1U� 6 34408TH LLF A D BLVD. 8501 SW 124th FL 33163 T 3TE206 A � HUNT86.673.6083 l' 801 80670 F. (800503 -1410 O I III �- 25.75° 25.75 —.1- - as.�s I-- 922 �— 38.25 38.25" 9.25' 7AW MAX ON C84M - a V i I� I� � � � r � r0 O r - I -f "M SERIES COMMERCIAL OUTSWINO STEEL DOOR (I-M.I.) MESIIER DOOR INC. 34408TANDNOOD BLVD. (250) &51 8870 F: (E0AL 0O303-1410 11 MCY ENGINEERING. INC. GLA23NO cbNSULTAMS 8501 SW 124th ST STE.205 A P: 305.271.0117 M�• F- 33183 F: 788.673.5083 w .KCYEn&eering.mm MCY.Englneering®Attnet FXMroxa x0 DATE D�CltIPItON oil r r Ff1 7AW MAX ON C84M - a V i I� I� � � � r � r0 O r - I -f "M SERIES COMMERCIAL OUTSWINO STEEL DOOR (I-M.I.) MESIIER DOOR INC. 34408TANDNOOD BLVD. (250) &51 8870 F: (E0AL 0O303-1410 11 MCY ENGINEERING. INC. GLA23NO cbNSULTAMS 8501 SW 124th ST STE.205 A P: 305.271.0117 M�• F- 33183 F: 788.673.5083 w .KCYEn&eering.mm MCY.Englneering®Attnet FXMroxa x0 DATE D�CltIPItON I �m w y's►saaaagr A a AO• • °x`/ o N h° USS C; 9�F 0 ®sOes-y�' ''•� be0 0 � � N o N t� 'N' SERIES COMMERCIAL OUTSWINO STEEL DOOR (LM.I.) MCY ENGINEERING, INC. i•:vLs10NB m MESIO=RR DOOR INC. G" A""o coNSMTANTS NO DATE DESCIDPr10N 7V 9 6 3440 STANDVMD BLVD. 8501 SW 124th ST STE.205 A P: 308.271.0117 a—ml m W P: (298) UNT 8870 F: L. 358811-1410 �K M 33183 F: 788.573.6083 www.MCYEnglneerhig.00m MCY.Engineering®Attaet ... �25.7W 25.75' 1 25 9.45 • • • • w • 382V 38.W � 9 • ' RW ANCMA s •• L4 aTa IST MORTAR • • • JOD4TFROM�ITOM • s r PLACE (T) ANCHOR ® EVERY OTHER MORTAR JONI (d) TOTAL PER JAMB w y's►saaaagr A a AO• • °x`/ o N h° USS C; 9�F 0 ®sOes-y�' ''•� be0 0 � � N o N t� 'N' SERIES COMMERCIAL OUTSWINO STEEL DOOR (LM.I.) MCY ENGINEERING, INC. i•:vLs10NB m MESIO=RR DOOR INC. G" A""o coNSMTANTS NO DATE DESCIDPr10N 7V 9 6 3440 STANDVMD BLVD. 8501 SW 124th ST STE.205 A P: 308.271.0117 a—ml m W P: (298) UNT 8870 F: L. 358811-1410 �K M 33183 F: 788.573.6083 www.MCYEnglneerhig.00m MCY.Engineering®Attaet 2.7" ice— Tl-�- 1. 01 00 Ta ®I T Imo— 3.S �I 7.63• 1 _J_ 7ir � 1.07' W —moi 4.11' � o'. c 1.13 123 F- T y .13° 0.W 1 �I 0.9T L 1 L I 1. o 4.75° 1125 — �` aaa4a v�°0,� d • /se 0.63' 0.62' 1.13° •. s @ (D 0 :O 9 9 I L _ � 138° 123• 039° 1.13 LIT w! ® °N• SERIES COMMERCIAL OUTSYVINO STEEL DOOR (I-M.I.) MICy ENGINEERING. INC. � Hr4=xe MESKER DOOR INC. oinmuo cor4lauir�wrs C 14D DATE DAMN 3440 STANDVOOD BLVD. 8501 3W 124th 9T SPE.20b A P. 306 71.0117 P: (288) 881.8870 F: (80 H AL 0503 -11 1410 MfAM1. , F7. 33183 F: 788.673.6003 www.MCYE—i.—rina.00m MCY.EOeiaeerinsOAtinet i • o • •.•.• • • ••..• 2' •3.S --j • • • • v a Loj� 1 1 h— 6.73° ice— Tl-�- 1. 01 00 Ta ®I T Imo— 3.S �I 7.63• 1 _J_ 7ir � 1.07' W —moi 4.11' � o'. c 1.13 123 F- T y .13° 0.W 1 �I 0.9T L 1 L I 1. o 4.75° 1125 — �` aaa4a v�°0,� d • /se 0.63' 0.62' 1.13° •. s @ (D 0 :O 9 9 I L _ � 138° 123• 039° 1.13 LIT w! ® °N• SERIES COMMERCIAL OUTSYVINO STEEL DOOR (I-M.I.) MICy ENGINEERING. INC. � Hr4=xe MESKER DOOR INC. oinmuo cor4lauir�wrs C 14D DATE DAMN 3440 STANDVOOD BLVD. 8501 3W 124th 9T SPE.20b A P. 306 71.0117 P: (288) 881.8870 F: (80 H AL 0503 -11 1410 MfAM1. , F7. 33183 F: 788.673.6003 www.MCYE—i.—rina.00m MCY.EOeiaeerinsOAtinet . ......... . •• ••• •• • • • •• • ••• ••• ••• • • • • • • • • • • • • • •• •• •• • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 1.t3" o 0.38° 123° 0.67 ®00® 0p0 O "60- � 1" 1.19° pn R 1.19° c o BS �{ 4.75' ,� FRAME(OAt6F c R�ntont VINYL 1 0.075° WEATHERSTRIP o II 5° o z q' � 0.94' Fes— Z o 8i YASIRAGAL 3 LL 40 H QJYL 2 V WEATHERSTRIP 8 a 7o o ry ee 91 suITFACFearPutF 41 Na'" �•^+� f`do OF. s -- - B OF OU OF MATIEW S MA r VER: wx MAum C 1/4" MAX. SHIM SPACE D 1/4° X 2-3/a° ELCO OR ITW CONCRETE SCREW STEEL E MASONRY - PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE H 1/4"x 1-3/4" ITW PFH CONCRETE SCREW STEEL J 3/8'X 5 PFH ITW DYNABOLT SLEEVE ANCHOR STEEL M 31W X S" TAPPER CONCRETE SCREW BY POWERS FASTENERS STEEL 1 "If STEEL DOOR PANEL 2 DOOR SKIN -16GA (0.060" THK. STEEL, FY = 4Q317 PSI MIN.) BY MESKER STEEL 3 FOAM 1.0 PCF MN. DENSITY. BY INSULFOAM LLC. POLYSTYRENE 4 DOOR TOP & BOTTOM CLOSER STEEL 5 LOCK BOX REINFORCEMENT STEEL 6 CLOSER REINFORCEMENT STEEL 8 #12 24 x I/7 SELF TAPPER STEEL 9 TUBE ANCHOR STEEL 10 #12-24 X 1° COMBNATION MACHINE / WOOD SCREW STEEL 16 ANSI LATCH STRIKE STEEL 17 DEADBOLT STRIKE STEEL 19 DEADBOLT STRIKE REINFORCEMENT STEEL 20 WEATHERSTRIP (PEMKO S -W) NEOPRENE 21 4-1/7 X 4-1/2X 0.125 TEMPLATE HINGE STEEL 22 STANDARD(LONG) DOOR HNGE TOP HNGE REINFORCEMENT STEEL 23 STANDARD (SHORT) DOOR HINGE MIDDLE BOTTOM REINFORCEMENT STEEL 25 FRAME -16GA (OW THK) BY MESKER STEEL 27 LATCH STRIKE REINFORCEMENT STEEL 28 FRAME HINGE REINFORCEMENT STEEL 30 MASONRY TEE' ANCHOR (MESKER PFM7,5) STS 35 WIRE ANCHOR STEEL 40 THRESHOLD NATIONAL GUARD PRODUCTS, INC. #696V) ALUMINUM 41 THRESHOLD(PEMKO2005 V) ALUMINUM 71 DESIGN HARDWARE DI -S SERIES DEADBOLT STEEL 72 DESIGN HARDWARE T SERIES ENTRY STEEL 76 DESIGN HARDWARE D2 -S SERIES DEADBOLT STEEL 77 DESIGN HARDWARE V SERIES ENTRY STEEL 82 SURFACE BOLT (IVES SB453OR ROCKWOOD 580$) STEEL 83 1 /4" X 2-1 /7 PPH MS STEEL 87 Z ASTRAGAL (MESKER) STEEL 88 SURFACE BOLT PLATE 1 STEEL 89 #8 X 1-1 /4" PPH SELF TAPPER • • • • • • s • • • • • STEEL . ......... . •• ••• •• • • • •• • ••• ••• ••• • • • • • • • • • • • • • •• •• •• • • • • • • • • • • • • • • • • • • • • • • • •• •• • • • •• •• ••• • • • ••• • • 1.t3" o 0.38° 123° 0.67 ®00® 0p0 O "60- � 1" 1.19° pn R 1.19° c o BS �{ 4.75' ,� FRAME(OAt6F c R�ntont VINYL 1 0.075° WEATHERSTRIP o II 5° o z q' � 0.94' Fes— Z o 8i YASIRAGAL 3 LL 40 H QJYL 2 V WEATHERSTRIP 8 a 7o o ry ee 91 suITFACFearPutF 41 Na'" �•^+� f`do OF. s -- - B OF