Loading...
RF-14-2287Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-221799 Scheduled Inspection Date: November 24, 2014 Inspector: Naranjo, Ismael Owner: DALEY, EUGENE Job Address: 467 NE 100 Street Miami Shores, FL 33138-2446 Project: <NONE> Permit Number: RF -10-14-2287 Permit Type: Roof Inspection Type: Final Roof Work Classification: Metal Phone Number Parcel Number 1132060170530 Contractor: TOP SEAL SERVICES Phone: (305)754-7844 Building Department Comments RE -ROOF TILE TO METAL INSPECTOR COMMENTS False Inspector Comments Passed house tented �Zlz Z�7dje� Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. November 21, 2014 For Inspections please call: (305)762-4949 Page 24 of 44 w RE: Permit # / b I 'A d � e Miami Shores Village Building Department INSPECTION AFFIDAVIT 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 DATE: --/ 0 1,36 / I �1 licensed as a (n) Contractor/ Engineer/ Architect, (Pont name and circle license T FS 468 Building Inspector License #: 1:7? 2�0� On or about` �� f� , I did personally inspect the roof deck nailing work (Date & time) Alqe__, (Complete Job Site Address) Based upon that examination I have determined the installation was anua sed on 553.844 F.S) Signature State of Florida County of Dade: to the Hurricane Mitigation Retrofit The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this day of 11CA 0 b e Notary Public, Sate of Florida at Large State of ®Ragr aa& Notery Public Joanna M Felicino F101"' F008 MY �0m,nission FF 082153 r,.n1r®s ol/1212018 _ 'General, Building, Residential, or Roaring Contractors or any individual certified under 466 F.S. to make such an inspection. Include photographs of each plane of the roof with permit #and address #clearly shown marked on the deck for each inspection Miami Shores Village CEIVE Building Department OCT 20 2014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (30S) 762-4949 FBC 20 BUILDING Master Permit NO.Wp ILI - PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC 14 ROOFING ❑ REVISION ❑ EXTENSION [-]RENEWAL ❑PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP ff/ / CONTRACTOR DRAWINGS JOB ADDRESS: -///7 City: Miami Shores County: Miami Dade Zip: 33 13 Folio/Parcel#:_11-MO(e '®/ %'®S3 ® Is the Building Historically Designated: Yes NO �>4D Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): �v� ✓� �. /c /f7 � Phone#: 366;* / rF c?//ho Address: City: MIAMI _!�717 rf0State: Zip: Tenant/Lessee Name: _ A14i4�;_ Phone#: _ 30-'5r _?S7 0 p llp CONTRACTOR: Company Name: ��� �' .q� �-� L� Phone#: 30!5"- 41ASE; 32_?b Address: c�� City: vel �P+- r'v't State: � � Zip: 3-3)Z7 Qualifier Name: N-�`� M4 --D t PI. -x Phone#: -SOS cqE�G -M-70 State Certification or Registration #: CCC (303 ©W Ck Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: IZip: Value of Work for this Permit: $ t•-i®t ® Square/Linear Footage of Work: Type of Work: ❑ Addition El Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: ,2S COEY -To L-0 rt -x C. Specify color of color thru tile:, Submittal Fee $ Permit Fee $ Scanning Fee $ Technology Fee $, Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ _ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimatedval eding $2500 plicant must promise in good faith that a copy of the notice of commencement and construction lien la brochure ill elivered t the person whose property is subject to attachment. Also, a certified copy of the recorded notice of co mencement ust be posted at hejob site for the first inspection which occurs seven (7) days after the building permit is issued. In the ab n e of such posted otice, the inspection will not be approved and a reinspection fee will be charged. Signature WNER or AGENT Th1e foregoing instrument was acknowledged before me this \� day of QC71QJ CJL 20 ) �1 by FCV DW -Ai who is personally known to me or who has produced as identification and who did take an oath. R The foregoing instrun'eht was ac l ed owbefore me this _I day of �/ b LT 20 1 k , by eOt- _% r1L4 0 t ti— . who ' ersona y known o me or who has produced as identification and who did take an oath. NOTARY PUBLIC: .t� NOTARY PUBLIC: Sign: Sign: Print: Print:�'�-- Seal:Seal',,' . APPROVED BY Plans Examiner Structural Review (Revised02/24/2014) � OPr,G , W Ly --ALP w woffisslow # Exms 7 F - RES Febra, ry 26, 2U'A' Zoning Clerk STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 MEDINA ,RONALD Top SEAL SERVICES CORP 5025 SW 75TH ST MIAMI FL 33143 Conons' With this license you become n one g rIllonaFlorldlans licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. - Every day we work toe way we do business in order to serve you better. For =the about our services, please log onto www.myflorldW[cense.com. There you can find more Information about our divisions and the regulations that impact you, subscribe to department newsletters and team more about the Departments Initiatives. Our mission at the Department Is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business In Florida, and congratulations on your now license! (850)487-1395 DETACH HERE ...... ..... RICK SCOTT, GOVERNOR KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL. REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD CCC1330 19 The ROOFING CONTRACTORYS F Nained below. IS CERTIFIED Under the provisions. of Chapter 489 FS. ExPhillon'datd: AUG -31, 201,6 - -M EDI NA, RONALD TOP -SEAL COW -LL 598 NW 64 ST - MIAMI F C *V-' v ISSUED. 06r29r2014 DISPLAYAS REQUIRED BY LAW Page 1 of 1 o..ra AI. n..l.e.•a.�r_nn1 12 -14 -1 -nn n -f. is IOni A CERTIFICATE OF LIABILITY INSURANCE 10/17/2014 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: U the eertiflcate holder is an ADDITIONAL INSURED. the paBoy(les) must be endorsed. H SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this cerdfleate does not eonW rights to the cartilicate holder in Hsu of such endorsement(s). PRODUCER De $alias Insurance 10110 SN 107 Ave. MIAMI, FL 33176 CONTACTNAIM PHONE F (305)274 -1234 Ro (786)472-8807 Mass- ALEX®DEZAYASINSDRANCE.CCM INSUREWRI COVERAGE NATC 4 BE$uarRA:Arch Specialty Lnsuranae Company 21199 umuRED Top seal services Corp Mr Ronald Medina 5025 SW 75 St Miami, FL 33143 INSURER B: BISURER C : USURER D: 111SURER E: WSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTR TYPE OF INSURANCE ACCORDANCE WITH THE POLICY PROVISIONS. im POLICYNUMBER AUTIIORa;EO REPRESENTATIVE Lam A OENERALLIAWLITY t ALC�tALUABMY CLAIAS42ADE ®OCCUR �/ X A(IL0012767-00 /06/2019 6/05/2016 EACHO CE $1,000,000 DAMAGETORENTEn $100,000 $10,000 -NMEXP(Anyramperwjn FERSONAL&ADV0UURY $1,000,000 GENERAL A lE $2,000,000 GE MAGGRrMTE: LaffAPPLMS Pat POLICY FRO• I.00 PRODUCTS -COUPIOPAM $1,000,000 5 AUTOMOBILE UASLLnY ANY AUTO SCHEDULED AUTOS AUTCS AU VN® HIREDAUTOSUTOS 11 6 BODILY MARY (Pffp�)ALLOWNED HELY O.WRY (Paraodd�01 S PROP DAMAGE $ 9 '= A UAB OTCEss UAB Id OCCUR CLAar.6rADE EACH DACE 6 AOGREAATE S wOR1[ERSCOMPOMMON ANDSPLOYERS'UABO'RY YIN ANYPROPREETCRIPARTMNDMDWCUTNE 0 OFPIER EJCCLUDmT �J (HO�msa,istmy to wo DESCROin OFFOOPERAMONSbelow NIA V RSTA $ 07H- EL EAgiACCiDT3dT 0 E.L MS ASE-EAEWL0YEE $ EL DESPASE-POLICY ULOT 15 DEsi'R "M OF OPEMMONS I LOCATIONS I VE10CLE6 ACORD IOI, AAi MmA R®a*e scheduK amore spx is'agvbecl) Commercial and Residential Roofing Contractor Waiver of Subrogation and Blanket Additional Named Insured Endorsement included. CERTIFICATE HOLDER CANCELLATION MIAMI SHORES VILLAGE SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WO.L BE DELIVERED DI 10050 NE 2 AVENUE ACCORDANCE WITH THE POLICY PROVISIONS. MIAMI SHORES, FL 33138 AUTIIORa;EO REPRESENTATIVE W 7888-2070 ACORID CORPORATION. All rights reSWV&d. ACORD 28 (2010/011) The ACORD name and logo are registered marts or ACORD Produced using Forms Boss Plus software. www.FomEsBow.com; Impressive Publishing 80-2W1977 http://www.topsealservices.com:2095/cpsess6722392566/horde/imp/view.php?actionlD=... 10/20/2014 CERTIFICATE OF LIABILITY INSURANCE Date 10/1712014 Reducer. Lien Insurance Company 2739 U.S. Highway 19 N. This CerWkat e Is Issued as a mach of information only and confers no do upon the certificate wonder. TMs Certificate does not amend, extend or alter Holiday, FL 34691 the coverage afforded by the policies below. insurers Affording Coverage MAIC # (727) 938-5562 Imn red; South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Holiday, FL 34691 tnsta A lion Irl "nce company 11075 Insurer a: Insurer C. Insurer D-- :Insurer InsurerE Coverages The Policies at nce listed rave bun Issued to We Insured nwmd adve rw Me Policy vated Indicated. Rourilralanam any requirernent ten or corallion al any contract or emu dour %tdr respect to vMch DSS cerh6cate way be issued or may gain, the insurance afforded by the policies described herein is subject to all the terms. exclusions, end con ttom of such PWICes: Aggregate limb sham may nave been reducod by paid claims. LT o Type} of Insurance, Policy Number Policy Effective Daate Oat- Policyi itraUan dare Limits (MIW'DDNY) (MMIDONY) GENERAL LIABIUTy Each occurrence Commercial General Ltabtlily Claims Made 13 Occur Damage to rented Werdses (EA ammence) S Med Exp Personal Adv rn}ury rel aggregate limit applies per. PolicyPr%ect� Q UAC Giftrat Products - trop Pao UTOMOMLE LIABILITY CarrOned Ski& UrM Any Auto (EA ArtWW0 Buddy injury AD Owed Autos Schedulad AtRns (Per Person) Badly RM Nired Autos Non -Owned AaAas #Per Accident) Property Damap 3 (Per Accident) EXCESSIUMBRELLA LIABILITY Each occurrence (ltcu/ p cwlm "0AggPeoate Deduc fible A Workers Compensation and WC 71949 01!0112014 01/0112015 x WC statu- OTH- Employters' Llabltltyta�ft ER E.L. Each Accident s1,r3DD.ttnD AM proprietoripameirleiteafte officerrimember excluded? NO E.I. Disease - F..a Emplo}w fit.MD,t�D It Yes, describe under special pmvlslorts below. E.L.1]iseaae - Policy lirniis i1,DD0,00D Other Lyon Insurance =Iwny Is A.M. Btu Company rated A- (Excellent). AMB # 12616 DescNptione of Operations&ot ationeNehideslExelusions added by Endrr'serrient 11pecial Provisions: Client ID: 91-67-374 Cove ardV applies to acture employee(s) of South East Emptoyw Leasing Servicim Inc. that are used to the following 'CUM cmnpaW: Top Seal Servicer: Corp, Coaerage only appites to inmies insured by Sol East Personnel Leasing, Inc. & 9ubshllarles atm empkryee(s), while lira cirt<{ irm FL. Curage does not apply W stittiatary erriployee(s) or independent corwactor(s) of Ura Client Company or any other entity. A iist of the active errnpkW(s) teased to the Client company Project frame: can he obtained by fate M a request W (727) 937-2M or by ral[I" (727) 938-5562. ISSUE 09-01-13 (CF) trace 71;W12033 CERTUICATE HOLDER CAAIL'.ELLATKri MIAMI SHORES VILLAGE 10050 NE 2 AVENUE 5 arhi et the abtnre be a the n irat= Ile msulg insurer will endeavor to mail 30 days wrrpen ladle to the eertiArate header named to the Will, but failure to do so shall tmpm no Wigalon at Habilft of any MW upon the msruer, IN amts or representatives. MIAMI SHORES, FL 33138 Ir- 10 Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION - ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: G! 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: �—ZI-16&W% Ile ¢ 001 L -C Property Address: '�7� S;� Roofing Permit Number: 3,31-2 CF Dear Building Official: I :7 L �� certify that I am not required to retrofit the roof to wall connections of my building because: The just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature Print Name Nota public State of Florida State of Florida =° Joanna M Felideno omrnission FF County of Dade ° Ex�pirres01M212018082753 The undersigned, being the first duly sworn, deposes and says that he s e is the owner for the above property mentioned. Sworn to and subscribed before me this day of Notary Public, Sate of Florida at Large • When Ble W valuation of the shucture for purpose of ad valorem taxation is equal to or more than $3oo ow.00, Ed the bullding was not cronstructed with FBc nor a 19% SFBC. Then you must provide a building application from a General Contrector for the Roof to Wall cronnectfon Hurttc m Myd9alon. O. Pregarlpa" OUR~ IOU ®as verr< oMcrca Yes 0 No C ROOF TYPE Type: Natural 0 LF ❑ Now Root D Re•Rooflng Recovering D Rewr D mwntm R . F StYS'iEM INFORMATM %no Reef Anis (MR SMaw MOOM ROC mon is u -mm Pis Wetch Roof Plan -illustrate all wets and sections, roof drains, scuppers, nveft scuppers ww overflow drains. McW&, dimensions of sectlorm and levels, d" "nuty d bumsh ms of elevated orsemm wrm and kmftn of parapets. Florida Building Code Edition 2010 Veloft HMI= to E.M UWM Pem* AmftWon Fort. HIGH-VELOOnY HURRICANE ZON Section D (Step®p S' pe„d Roof Sv_; t„ em) Roof System Manufacturer: 4-1., 4 Product Approval Number. •�,� 1' Minimum Design Wind Pressures, N Applicable (From RAS 127 or Calculations): P1: P2: P3: Maximum Design Pressure Product Approval Specific System: Method of file at chment: Roof Stops: 12 r File : Ridge VOn nation? Strep Sloped Roof System description �� Deck Type: & Spacing: Covering: Type & Size Drip • • • • ASI r • e r • • t i r ' - r & Spacing: Covering: Type & Size Drip ' ivtetal KoofAystem MIAMaC�►DE Miami -Dade County M HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section D Metal Roof System Roof System Manufacturer: Drexel Metals Notice of Acceptance Number:13-0503.03 Minimum Design Wind Pressures, (from RAS 127 or Calculations): P 1: ,•1... P 2: 68,1 P 3• 100.5 Maximum Design Wind Pressures, (From the NOA Specific system): -150 psf Fill In the speci'flc roof assembly components. !f a component is not required, insert not applicable (n/a) In the text box. Roof Slope: "/12" Roof Mean Height:.13 f#. Clip or Screw Spacing for Metal Roof Panel Attachment Field: El ­o/c Perimeters: El " o/c Comers: 12 . " o/c Number of screws required per clip: Perimeter Width: El ft, Screw Type, Size, & Gauge for Clip or Metal Panel Attachment: #10 Pancake head screws 1-112" Deck Type: /8" . P - Optional Nailable Substrate: NIA Optional Nailable Substrate Attachment Method: N/A Optional Insulation: NIA Optional Insulation Attachment Method: =NIA Fire Barrier: GAF Versashield Underlayment Type: 30# ASTM D214 Type I I Undedayment Fastener Type: 1-1I4" RS Coil Nails 1-5/8" Tincaps Optional Peel & Stick Membrane: N/A Metal Roof Panel: DMC 150 SS-24ga Steel Panel Drip Edge Size & Gauge: 73" face 26 ga.-- Drip Edge Material Type:—GalvinizedMetal— Drip Edge Fastener Type: 11-1/4" RS Coil nails Hook Strip/Cleat gauge or we€ght:1n/a-- SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DMC 150 SS-24Ga. Steel Panel over Plywood deck LABELING: Each unit shalt bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 13-0328.04 consists of pages I through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 1 of 11 NIAMES MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami. Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidad"oy/econon Drexel Metals Inc. 1234 Gardnier Lane Louisville, KY. 40213 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: DMC 150 SS-24Ga. Steel Panel over Plywood deck LABELING: Each unit shalt bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 13-0328.04 consists of pages I through 11. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 1 of 11 ROOFING SYSTEM APPROVAL: Cateaory Sub -Category: Material: Deck Tyne: Maximum Design Pressure Roofing Metal, Panels (Non -Structural) Steel Wood -165 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions DMC 150 SS — 240a. Length: various Steel Panel Height: 1-1/2" Width: 16" Thickness 24 ga Min. Yield Strength: 50ksi. DMC 15OSS Butterfly Base: CIip Length: 4.5" Height: 1-1/4" Width: I" Thickness: 22ga Upper Clip: Length: 5.045" Height: 0.929" Width: 0.40" Thickness: 24ga DMC 15OSS Base: Continuous Butterfly Length: 120" Clip Height: 1-1/4" Width: l" Thickness: 22ga Upper Clip: Length: 5.045" Height: 0.929" Width: 0.40" Thickness: 24ga 24 ga. DMC 150SS Length: 2-1/4" Fixed Clip Height: 1-5/8" Base Width: 15/16" Thickness: 24ga 22 ga. DMC 15OSS Length: 6-1/4" Fixed Clip Height: 1-5/8" Base Width: 3/4" Thickness: 22ga Test Product Specifications Description TAS 110 Corrosion resistant, galvanized steel or galvalume standing seam metal panel. Two piece panel clip (base and upper clip) used for the field conditions of DMC 150 SS panel assembly System A. Two piece panel clip (base and upper clip) used for the perimeter and comer conditions of DMC 150 SS panel assembly System A. One piece panel clip used for the field conditions of DMC 150 SS panel assembly System B. One piece panel clip used for the perimeter and corner conditions of DMC 150 SS panel assembly System B. NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 2 of 11 a TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Product Dimensions Test Product Specifications Description Bostik 70 -OSA N/A TAS 110 Heavy duty construction adhesive. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Akzo Nobel Coatings, Inc. Lab Form ASTM G 153 PRI Asphalt Technologies, Inc. AKZC-001-02-01 ASTM B 117 10/08/02 AKZC-001-02-02 AKZC-001-02-03 AKZC-001-02-04 AKZC-001-02-05 DMC -006-02-01 TAS 125 03/11/13 DMC -009-02-01 TAS 100 03/11/13 Architectural Testing. 56842.02-122-18 TAS 100 06/08/05 Hurricane Test Laboratory, Inc. 0287-0311-07 TAS 125 08/07/07 m ECOUNTY �F-gwzormj NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 3 of I 1 System B: Deck Type: Deck Description: Slope Range: Maximum Uplift Pressure: DMC I50 SS — 24Ga. Steel Panel 16" wide Panel Wood, Non -insulated New Construction 19/32" or greater plywood or wood plank. 2": 12" or greater See Table B below Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d annular Maximum Design Pressures -90 sf- ring shank nails spaced at a maximum distance specified below in Table B. In reroofing, -165 sf where the deck is less than 1942" thick (Minimum 15/32") The above attachment method must 6" o.c. be in addition to existing attachment. Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" 22 ga. DMC 15OSS Fixed Cli side -lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps 12" o.c. and 12 gauge t '/a" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered Bostik Seam Sealant None rows 12" o.c. in the field of the roll or any approved underlayment having a current NOA. Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for 900 fire ratings of this roofing system assembly as well as the location of the fire barrier within I. Extrapolation shall not be allowed the assembly. See Limitation # 1. Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and with the current published installation instructions and details in DMC Association of Regional Manufacturers Installation Manual. Metal Panels and Install the "DMC 150 SS — 24Ga. Steel Panel 16" wide Panel" including flashing Accessories: penetrations, valleys, end laps and accessories in compliance "DMC Association of Regional Manufacturers" current, published installation instructions and in compliance with the minimum requirements detailed in Roofing Application Standard RAS 133. Panels shall be secured along the male rib with approved Panel clip listed below in Table B with ttiio corrosion resistant #10 pancake head fasteners of sufficient length to penetrate through the sheathing a minimum of 3/16". The panel clips are to be placed at a spacing listed below in Table B. The female rib of panel is placed over the male/clip assembly and seamed. See Detail B herein. TABLE B MAXIMUM DESIGN PRESSURES Roof Areas Field Peri ` r and Cor er Option 1 Perimeter and Corner' Option 2 Maximum Design Pressures -90 sf- 65f -165 sf Plywood Fastener Spacing 6" o.c. 6" o.c. 4" o.c. Clip Type 24 ga. DMC 150SS Fixed Clip 22 ga. DMC 15OSS Fixed Clip 22 ga. DMC 15OSS Fixed Cli Maximum CHR Spacing 16" o.c. 12" o.c. 8" o.c. Bostik Seam Sealant None (1)1/4" bead None Mechanical Seam 909 900 1800 I. Extrapolation shall not be allowed ADE MMMMUtJiY NOA No.: 13-0503.03 Expiration Approval Date: 0912/13 Page 5 of 11 LIMiT noir s R 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement: "Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. QMLAMI•DADE COUNiY EN e 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 6. Panels may be jobsite roll formed with machine model #9600406 from DMC Association of Regional Manufacturers. NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 6 of 11 r PROFILE DRAWINGS 16" 1/2" APPROYEq DCM 150 SS - 24GA. STEEL PANEL ,+ r rr•TJX%�' � � N Jlff•�' 1 DMC 15088 BUTTERFLY CLIP NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 7 of 11 1 5t8" DMC 15OSS CONTINUOUS BUTTERFLY CLIP 71 8 21411 24 GA, DMC 15OSS FIXED CLIP !m 22 GA, DMC 15OSS FIXED CLIP cmmkkulw=� NOA No.: i3 -0503.Q3 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 8 of 11 DETAIL A (Field Conditions) (Perimeter and Corner Conditions) NOA No.: 13-0503.03 MiAMI.OItDEC � Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 9 of 11 DMC'E50SS t1m DMO 1 DOSS CI (2) #10 - 13x V PF UNDERtAYME' SUBSTRA DETAIL A (CONT.) (Seam Detail System A— Field, Perimeter and Corner Condition) DETAIL B DMC 15088 C! (2) #'f�0-13 x 1" P` } SUBSTRA (Field Condition Seam Detail) NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 10 of 11 DETAU, B (CONT.) CORNER ZONE SEAM ADHESIVE (1W BEAD B087IK Tt1-06A) DMC 15088 PANEL DMC 16088 CLIP (2) #10 -13 x 1" PHl UNDE iLAi ME ! SUBSTRATE (Perimeter and Corner Condition — Option X Seam Detail) [7MC 15t}00 t1m DMC 15OSS CI (2) #10 -13 x 1" P� UNDERLAYME SUBSTRA (Perimeter and Corner Condition — Option 2 Seam Detail) END OF THIS ACCEPTANCE NOA No.: 13-0503.03 Expiration Date: 06/26/18 Approval Date: 09/12/13 Page 11 of 11 MIAMI-DADE COUNTY MIAMI-M PRODUCT CONTROL SECTION 11805 SW 26 Street Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) ym!%miamidade.eov/economy GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: VersaShicie Fire -Resistant Roof Deck Protection and VersaShiele SoloTm Fire -Resistant Slip Sheet LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. I I-1110.09 consists of pages 1 through 3. The submitted documentation was reviewed by Juan E. ColIao, R.A. NOA No.: 13-1104.06 MIAMbDADBCOUNTY Expiration Date: 02/07/17 Approval Date: 02/20/14 Page I of 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Underlayment Material: Fiberglass SCOPE: This acceptance is for VersaShield® Fire -Resistant Roof Deck Protection (a.k.a "VersaShield® Underlayment") and VersaShield® SoloTm Fire -Resistant Slip Sheet (a.k.a "VersaShield SoloTM"), as described in this Notice of Acceptance, for use with approved prepared roof assemblies. Designed to comply with the Florida Building Code and the High Velocity Hurricane Zone of the Florida Building Code. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions VersaShielde Fire- 42" x 100' rolls Resistant Roof Deck Protection VersaShield' Solo"m 72" x 166.7' rolls Fire -Resistant Slip Sheet MANUFACTURING LOCATION: 1. Conover, NC Test Snecif3cations Product Description ASTM D 226 Non -Asphaltic fiberglass -based underlayment Type II and/or fire barrier. UL790 Non -Asphaltic fiberglass -based slip sheet and/or fire barrier. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GAF -270-02-02 ASTM D 226 11115110 ELK -063-02-01 TAS 100 09/27/01 Underwriters Laboratories Inc. 99NK45831 UL790 03/21/00 1 ONK 11990 UL790 05/18/11 R19254 ASTM D 226 09/13/01 08CA37926 UL790 09/23/09 08CA49140 PRI Asphalt Technologies, Inc. ELK -069-02-01 TAS 100 03/04/02 BRY-003-02-01 TAS 117(B) 03/19/02 BRY-003-02-01 TAS 114 (H) INSTALLATION: 1. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoloTM Fire -Resistant Slip Sheet shall be installed in strict compliance with applicable Building Code. 2. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield SoloT"' Fire -Resistant Slip Sheet shall be installed with a minimum 4 -inch head lap in a shingle layer fashion. 3. VersaShield® Fire -Resistant Roof Deck Protection shall be mechanically fastened with approved fasteners in compliance with Florida Building Code 1518.2 when used in lieu of a code prescribed ASTM D 226 Type 11 underlayment. MiAMtDApSCOUN7Y NOA No.: 13-1104.06 Expiration Date: 02/07/17 Approval Date: 02/20/14 Page 2 of 3 LINIITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. VersaShield® Fire -Resistant Roof Deck Protection shall not be left exposed as a temporary roof for longer than 30 days of application. VersaShield® SoloTM Fire -Resistant Slip Sheet shall not be left exposed to the weather. 4. VersaShield Fire -Resistant Roof Deck Protection and VersaShield So1oTm Fire -Resistant Slip Sheet are a component used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. VersaShield® Fire -Resistant Roof Deck Protection or VersaShield SoloTm Fire -Resistant Slip Sheet may be used with any approved roof covering Notice of Acceptance listing. VersaShield Fire -Resistant Roof Deck Protection or VersaShield SoloTM Fire -Resistant SIip Sheet may be used as a component part of an assembly in the Notice of Acceptance. If VersaShield® Fire -Resistant Roof Deck Protection or VersaShield® SoloTm Fire -Resistant Slip Sheet is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 6. VersaShieldo Fire -Resistant Roof Deck Protection and VersaShield® SoloTm Fire -Resistant Slip Sheet are a non - asphaltic underlayment that may be used as a fire barrier for prepared roof assemblies. For fire classification of specific roof assemblies using VersaShield Fire -Resistant Roof Deck Protection or VersaShield® SoloTm Fire - Resistant Slip Sheet refer to a current Approved Roofing Materials Directory for fire ratings of this product. 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, yellow line to identify the ASTM Standard designation or logo, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. ]APPROVED[ BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: I. This Notice of Acceptance. 2. Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this material. END OF THIS ACCEPTANCE M/4MI•pAOECOUNiY NOANo.: 13-1104.46 Expiration Date: 02/07/17 Approval Date: 02/20/14 Page 3 of 3 TGFU.R25244 - Roofing Systems Page Bottom See General Information for Rooflna Systems DREXEL METALS INC 7450 MONTE VIDEO RD JESSUP, MD 20794 USA TGFU.R25244 Roofing Systems Roofing Systems OTHER SYSTEMS Class A R25244 Page I of 2 Metal panels Identified as "DMC 5-V, DMC 2005, OMC 1755, RMC 15OSL, DMC 15OSS, DMC 10OSS, DMC 45OSL and DMC LOONS". One or more layers of Elk Corp. "VersaShield Underiayment," mechanically fastened, may be used In lieu of the Barrier Board in all combustible Classifications. 1. Deck: C-15/32 Incline: Unlimited Impact: Class 4 Barrier Board: — 1/4 In. min. G -P Gypsum DensDeck® with all joints staggered a min of 6 in. from the plywood joints. Ply Sheet (Optional): — Any UL Classified Type G3, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or VL Classified prepared roofing accessory or WR Grace "Ice and Water Shield". Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. 2. Deck: NC Incline: Unlimited Impacb Class 4 Barrier Board: — 1/4 in, min. G -P Gypsum DensDeck®. Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace "Ice and Water Shield". Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. 3. Deck: NC Incline: Unlimited Impact: Class 4 Barrier Board: — 7/16 OBS or 5/8 In. plywood over polyisocyanurate insulation board or polyisocyanurate composite boad, any thickness. Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace "Ice and Water Shield". Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. 4. Deck: NC Incline: Unlimited Impact: Class 4 Insulation: — Polyisocyanurate, glass fiber, perlite or wood fiber, any thickness. Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace "Ice and Water Shield". Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. S. Deck: NC Incline., Unlimited Impact: Class 4 Insulation: — None required, however any UL Classified insulations may be used over open purlin spans. Any combination and any total thickness of insulation may be used. Surfacing. — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. 6. Deck: C-15/32 Incline: Unlimited Impact: Class 4 http J/database.ul.com/cgi-bin/XYV/template/LISEXT/ I FRAME/showpage.html?name=TGFU.R25244&ccnshorttitle=Roofin... 9/4/2014 TGFU.R10689 -Roofing Systems TGFU.R10689 ?:. Roofing Systems Paoe Bottom Roofing Systems eral.Information_for_Roolino System GAF R10689 1361 Alps Rd Wayne, N3 07470-3700 USA f e Any UL Classified peel and stick underlayment may be used in conjunction with "VersaShield(D Fire -Resistant Roof Deck Protection" and "VersaShield@,13niierlayment" In any of th@;following systems. OTHER SYSTEMS Class A 1. Deck: C -15/52 --or spaced sheathing Incline: Unlimited Page 1 of 4 linderlayment: — One ply' VersaShleld@ Fire -Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Ply Sheet: — One ply Type 30 base sheet or "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened, Shingles or Panels: — UL Classified or Listed Steel or copper. 2. Deck: C-15/32 Incline: Unlimited Underlayment: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — UL Classified or Listed Class A asphalt glass fiber shingle. 3. Deck: C-15/32 Incline: Unlimited Underlayment: — Two plies "VersaShield@ Fire -Resistant Roof peck Protection" or "VersaShield@ Underlayment." Shingles or Panels: — UL Classified or Listed Aluminum. 4. Deck; C-15/32 Incline: Unlimited Underlayment: — Three plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Membrane: — Endur -Ali "Cedar -shake." 5. Deck: C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One or more plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Panels: — Any UL listed or Classified standing seam steel, steel or copper. 6. Decte C-15/32 or Spaced Sheathing Inclines Unlimited Underlayment: — One ply "VersaShield@ Fire -Resistant Roof peck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — UL Listed stone coated, direct to deck, non -batten systems. 7. Deck: C-15/32 or Spaced Sheathing Incline: Unlimited Underlayment: — One or more plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield® Underlayment" mechanically fastened. Roof Panels: — Steel panels, fastened to 2 x 2 wood battens http://database.ul.comlcgi-bin/XYV/templatelLISEXT/] FRAMR/showpage.html?name=TOFU.R10689&ccnshomitle=Roofin... 9/4/2014 TGFU.R10689 - Roofing Systems 8. Deck: C-15/32 Incline: Unlimited Page 2 of 4 Underlayment: — One or more plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "Versashield@ Underlayment" mechanically fastened. Shingles:.— UL Classified or Listed Class A asphalt glass fiber shingle. I. Deck: C-15/32 Class B Incline: Unlimited Underlayment: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — Any UL Classified or Listed steel, copper, aluminum. 2. Deck: Spaced Sheathing Incline: Unlimited Underlayment: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShleld@ Underlayment." Shingles or Roof Panels: — VL Classified or Listed Steel or copper. 1. Deck: C-15/32 SINGLE PLY MEMBRANE SYSTEMS Class A - Fully Adhered Incline: 1-1/2 Slip Sheet: — Two plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShleid@ Underiayment." Membrane: — Any UL Classified except TPO (Actual incline is determined by the maximum existing membrane Classification incline, but cannot exceed 114:12). 2. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield@ Fre-Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Membrane: — Any UL Classified PVC, fully adhered. 3. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Insulation: — Any UL Classified, any thickness (except EPS). Membrane: — Any UL Classified except TPO (if Insulation is used, membrane must be currently UL Classified for use over It. Actual incline Is determined by the existing membrane/insulation Classification, but cannot exceed 2:12). I. Deck: C-15/32 Class B - Fully Adhered Incline; 2 Slip Sheet: — One ply "VersaShield@ Fre-Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Membrane: — Duro-Last Inc. "Duro-Last" (PVC), fully adhered. 2. Deck: C-15/32 Incline: 1-1/2 Slip Sheet: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Membrane: — Any UL Classified, except TPO. Actual incline Is determined by the max existing membrane Classification incline, but cannot exceed 11/2:12. 1. Deck: C-15/32 Class A - Mechanically Fastened Incline: 1-1/2 Slip Sheet: — Two plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShleld@ Underlayment" Membrane: — Any UL Classified (Actual Incline is determined by the maximum existing membrane Classification incline, but cannot exceed 11/2:12). 2. Deck: C-15/32 Incline: 2 Slip Sheet: — Two plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Membrane: — Any Classified PVC, mechanically fastened. http://database.ul.com/cgi-bin/XYVhernplate/LISEXT/1 FRAME/showpage.html?name=TGFU.R l O689&ccnshorttitle=Roofin... 9/4/2014 IGFU.R25244 - Roofing Systems Page 2 of 2 Barrier Boards — 1/4 in. min. G -P Gypsum DensDeck® with all joints staggered a min of 6 in. from the plywood joints. Ply Sheet (Optional): — Any UL Classified Type G1, G2 or G3 base/ply sheet, Type 15, 20 or 30 felt or UL Classified prepared roofing accessory or WR Grace "Ice and Water Shield". Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. Class C Coated steel panels (surfacing) Identified as "DMC 54", "DMC 2005", "DMC 1755", "DMC 150SL", "DMC 150SS", "DMC 4SOSL" and "DMC 10ONS". Aluminum panels Identified as "DMC 1755". Copper panels identified as "DMC 10OSS". 1. Deck: C-15/32 Incline: Unlimited Surfacing: — Coated Steel, aluminum or copper roofing panels, mechanically fastened or with steel screws when roof deck fasteners (panel clips) not required. La ttUpdated on 2013-09-27 Ow-estions? Print this pane Terms of Use Paoe Ton p 2014 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" Is included in the UL Mark, please search the UL Environment datahm for additional Information regarding this product's certification. The appearance of a company's name or product In this database does not in Itself assure that products so Identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained In the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented In their entirety and In a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. in addition, the reprinted material must include a copyright notice in the following format: "@ 2014 UL LLC". http://database.ul.com/cgi-bin/XYV/temp!ate/LISEXTI I FRAiviE/showpage.html?name=TGFU.R25244&ccnshorttitle=Roofin... 9/4/2014 TtFU.R10689 - Roofing Systems 3. Deck: C-15/32 Incline: 2 Page 3 of 4 Slip Sheet: — Two plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Insulation: — Any UL Classified, any thickness (except EPS). Membrane: — Any UL Classified (if insulation is used, membrane must be currently Classified for use over it. Actual Incline is determined by the existing membrane/insulation Classification, but cannot exceed 2:12). 1. Deck: C-15/32 Class B - Mechanically Fastened Incline: 2 Slip Sheet: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment." Membrane: — Duro-Last Inc. "Duro-Last" (PVC), mechanically fastened. 2. Deck: C-15/32 Incline: 1-1/2 Slip Sheet: — One ply "VersaShleld@ Fire -Resistant Roof Deck Protection" or "VersaShleld@ Underlayment." Membrane: — Any UL Classified, Actual Incline Is determined by the max existing membrane Classification incline, but cannot exceed 11/2:12. 1. Deck: C-15/32 MAINTENANCE AND REPAIR Class A Incline: Unlimited Existing Roof System: — Any Class A UL Listed shingle. Slip sheet. — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — Any UL Listed steel, copper, aluminum or Class A asphalt glass fiber shingles. 2. Deck: C-15/32 Incline: Unlimited Existing Roof System: — Any Class A, B or C shingle. Slip Sheet: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — UL Listed Class A asphalt glass fiber shingles. 3. Deck: Slats spaced 11/2-1n. Incline. Unlimited Existing Roof System: — Existing wood shake roof. Slip Sheet: — Two or more plies "VersaShield@ Fre-Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — Any UL Listed steel, copper or Class A asphalt glass fiber shingle. 1. Deck: Slats spaced 11/2 -in. Class B Incline: Unlimited Existing Roof System: — Existing wood shake roof to retain existing Listing. Slip Sheet: — One or more plies "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShield@ Underlayment" mechanically fastened. Shingles: — Any UL Listed steel, copper, aluminum or Class A asphalt glass fiber shingles. 1. Deck: C-15/32 Class A, B or C Incline: 11h, see Note i Existing Roof System: — Any Class A, B or C built-up roof system. Slip Sheet: — One ply "VersaShield@ Fire -Resistant Roof Deck Protection" or "VersaShleid@ Underlayment" mechanically fastened. Roof Coverings — Any BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC TPO or TRE membrane system. Note 1: Classification (A, B or C) and max incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck, but not to exceed V/z-in. slope. Last Undated on 2014-06-11 Questions? Print this Dade �i f -Use Pane Tao http://database.ul.com/egi-binIX'YVItemplatelLISEXT II FRAMEtshowpage.html?name=TGFU.RI0689&ccnshorttitle=Roofin... 9/4/2014 O'GFU.R10689 - Roofmg Systems Page 4 of 4 0 2014 UL LLC When the UL Leaf Mark is on the product, or when the word "Environment" is Included in the UL Mark, please search the UL Environment database for additional Information regarding this product's certification. The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's follow -Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, systems, and/or Certifications (files) must be presented In their entirety and In a non- misieading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must Include a copyright notice in the following format: "p 2014 UL LLC". httpJ/database.ul.com/egi-bin/XYV/tempiate/LISEXT/I FRAME/showpage html?name=TGFU.R10689&ccnshorttitie=Roofin... 9/4/2014 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it Is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. Aesthetics-Workmanshlp: the workmanship provisions of Section R4402 are for the puose of rp providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color -or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renal ed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5• Ponding water: The current roof system and/or deck of the building l and cause water to pond (accumulate) in low -long areas of the roof. Pounding can be an indication ofnot drain estructural y distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. Overflow scuppers (wail outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scupper; in accordance with the requirements of Sections R4402, R4403 and R4413. 7• Ventflatlon: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additiona venting which can result in extending the service life of the roof. Owner/Agent's Signature 9A Contractor Signature Date Revised on 7/9/2009 LD