MC-14-2374 (2)�A Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: MECHANICAL FBC 2® Permit No. 'LAO –� Master Permit No. EZ GC JOB ADDRESS: 320 N E 100 ST City: Miami Shores County: Miami Dade Zip: 33138-2421 Folio/Parcel#: 11-3206-013-5460 Is the Building Historically Designated: Yes NO `� Flood Zone: OWNER: Name (Fee Simple Titleholder): ETHAN S GROSSMAN Phone#: (404)895-2307 Address: 320 NE 100 ST City: MIAMI SHORES State: FLORIDA Zip: 33138 TenandUssee Name: Phone#: Email: CONTRACTOR: Company Name: SOLAR BEAR SERVICES Phone#: (305)863-1830 Address: 10125 NW 116 WAY #10 City: MFDLFFY� State: FLORIDA Zip: 33178 M 1 Qualifier Name: 1 A M% VEX LL AX Phone#: clb • %3 ' d220 State Certification or Registration #: CAC1817134 Certificate of Competency #: Contact Phone#: (305)863-1830 Email Address: MC-,YLP—r!NF&9a .Ag2it g=L . coM DESIGNER: Architect/Engineer: t'l 1 IPS Phone#: rel, Value of Work for this Permit: $ _Square/I.inear Footage of Work: 2492' Type of Work: ❑Address ❑Alteration ❑New idRepair/Replace ❑Demolition Submittal Fee $ 6U ` Permit Fee $ ��t CCF $ ® CO/CC $ Scanning Fee $C1' JOC-) Radon Fee $ S ^a DBPR $ Bond $$ Notary $ Training,/Education Fee (/$ Technology Fee $ G e LJ�J Double Fee $ Structural Review $ T TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will nojbe approved and a reinspection fee will be charged. Signature_iV�,�/�� Signature Owner or Agent The foregoing instrument was acknowledged before me thisAhj— day of 00—T. , 20 f �,, by-r)4JgW 0 QDMM KIIV who is ersonally known to me or who has produced L. As identification and who did take an oath. NOTARY PUBLIC: Sign: - Print: C My Commission APPROVED BY Contractor The foregoing instrument was acknowledged before me this day of -�� , 20 JA by MagL V who isjjrsonally known me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: .att A9AI�Aas. w.�-•--- COMMISSION # FF142531 My EXPIRES: Sept. A 2018 WWW.AAR0HbURY.001G '1030T./Im Examiner Structural Review Revised 3/12/2012)(Revised 07/10/07)(Revised 06/10/2009)(Revised 3/15/09) COMMISSION 0 FF142531 EXPIRES: Sept 15, 2018 Zoning Clerk STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD (850) 487-1395 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 VEILLEUX, MARK SOLAR BEAR SERVICES LLC 10125 NW 116TH WAY SUITE 10 MEDLEY FL 33178 Congratulationsi With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business In order to serve you better. For information about our services, please log onto www.myfloridalicanse.com. There you can find more Information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's Initiatives, Our mission at the Department Is: license Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new ticensel DETACH HERE RICK SCOT!', GOVERNOR STATE OF FLORIDA DEPARTMENT OF BUSINESS AND 401, ' PROFESSIONAL REGULATION CACI 817134 IS.SUEb: 09!23/2014 CERTIFIED AIR COND CONT_R,_ VEILLEUX, MAFtEC_:. SOLAR BEAR SERVICES.LLC:=:, IS CERTIFIED under the provisions of Ch.489 FS. Explreltan date : AUG 31, 2018 U4082300=0 KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD CACM7134 The CLASS B AIR CONDITIONING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS.- Expiradon date: AUG 31, 2016 VEILLEUX MARK SOLAR BEAR SERVICES,LIC"•_.. 10125 NW 118 WAY • :'_'`h�;".M,,,w MIAMI7"8' FC331 .?'!W.% O . -. ,;,;+� e'•s"•' s s ' pyi�•�. t:t • 51�•, , '`L1�'e'�'t ��,y�. ...... ..w.-. a..w•i:.:r........ .._h. ::5. ..���:.. .'.+sed• �5�•�s+...�.ti.-�1�... i.i.:. ISSUED.* 091=014 DISPLAYAS REOUIRED BY I AW SEO # 1-140923011MUR i Certificate of Product Ratinas AHRI Certified Reference Number: 5221701 Date: 2/25/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: XC14-030-230-** Indoor Unit Model Number: CBX27UH-036-230*+TDR Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: XC14 SERIES Series name: Raw Manufacturer responsible for the rating of this system combination Is LENNOX INDUSfiR1ES, C. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, Independent, third party testing: FootNi 5151:. 006.9• -.••• • 0000•• • ease • a • • •• •• 0000•• 0000•• • •• • •••• • ` Ratings followed b an asterisk ' indicate a voluntary rerate of previously • • • • 8 Y () ry p y published data, unless accompanied with a WAS, which indicates an Involuntary cerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) Iced on this Certiflcate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and 3 confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONOMONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which Is listed at bottom right --------- @2014 ________ ©2014 Air -Conditioning, Heating, and Refrigeration Institute ^x+3' • • ' • 10;543 :i27,61:1. , RESIDENTIAL LOAD CALCULATIONS Based' on ACCA Manual J8ae ` a 01:1,01fng ® Heating /tin 0-affty _ Irtstnrcifons: Erdardafa Into yeftw fly .Alf other Reich am reaufredt•x I. Grev Bolds am u9sulmComfiflons: GROSSMAN Indoor Design Heating db 72 I Vtrcmr 99% till I, 04J = 22 ` . Address NE 100 liTREET Indoor 0est db 75 Summar 1 db 1 " . 15' & S FL 33138 Indoor FIN68; Certificate of Product Ratinas AHRI Certified Reference Number: 5698778 Date: 2/25/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: XC14-036-230= * Indoor Unit Model Number: CBX27UH-036-230*+TDR Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: XC14 SERIES Series name: Manufacturer responsible for the rating of this system combination Is LENNOX INDUSTRIES, INC. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, Independent, third party testing: FootNt 5151:2 0000•• '••••- 0000 •• 0 0000 • •• 0000•• •• • •• •• •• • .••••• • 0000•• • • • •• • 0000 • 00 ' Ratings followed by an asterisk (') indicate a voluntary rerete of previously published data, unless accompanied with a WAS, which indicates an involuntary rere0te0. • DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for the product(s) listed on this Certlflcate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRL This Certificate shall only be used for Individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or In part, be reproduced; copied; disseminated;M- personal entered Into a computer database; or otherwise utilized, In any form or manner or by any means, except for the user's Individual, and confidential reference. AIR-CONDnTONING,HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate' link we make life better' and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which Is listed above, and the Certificate No., which Is listed at bottom right 130378508150312432 02014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: RESIDENTIAL LOAD CALCULATIONS Based° on ACCA Manual JBae tresLtrcNarrs: ErrW data lea Holds . M other Bells are G cafcukwwm Desi Caratlo� Fromm ` hMoor db s2 Whter db 39` 22 + , Address RE 100 STREET Indaa db 75 Surmrer 1% db CTD f raft MIAMI SHORES FL. 33138 hdoorDesl RFI Grabs Load Florida rEleretlon ,11 �� -.:' dime,e=1 All _ `. x Heat Total Glass Area Single Double I TwPLe Jalousie 21.58 1232 1 924 21.58 ft FL) V X Heating 7-7 a Double . COMES TOM Arean (Sq FL) NorthArea X Coaling 29 21 is 29 '< ' X49 ' Check box below NEtNWX Cooly 61 44 - and � � to add internal Area 45 35 31 48 Sliding Glass Door Shading. South ® X Cooing No Int-.0Shm1a Area 0 0,cr O FK 73 60 54 73 Et SEISW X Cooling :. 0 .` - Area E a W X Cooling 84 70 64 84 11 Doors @ Dre 3 Ix e X Heating Storm F3 js 7.70 4.62 0 42 a 0 - X Cooling 7.60 12 7.50 1750 Gross Exposed(Sq. FL) E1E3 X a Net Wag Frame-SIdIng Arae Chrfek H R 2 O Insul + R-11 R-13 R -t8 R 2f: 4. 1.89 1.78 1.39 1.32 Exposed Wag leas % Heating BoePd lnstclaties 0 :. 818 - 0 s 0 all glass and doors is used": r Wood Studs X Cooling ®' 5.39 206 1.77 1.12 0.95 0 519 0 0 0 No Board h dation HeightArea O lrmul Rd hmd -R-.Z-teat R•151rmul . Not Wag (Above Grade 29 - i6 - XEYDe X Heating 1285 8.92 3.85 1.32 1232 0 0 Concrete Block b board Insulation No htertar finish X Cooling 8.78 4.04 263 0.90 1232 0 0 0 t Net wan (8 Below Grade) 1,118 I 0 kcal R-2 kmul R knell R-1091. kcal Concrete Block wd board Insulation 0 X O m X H 275 1.98 1.58 79 No htertor finish 0 1 0 1 0 1 0 Calling (Sq. FL) Nam R78 6' R30 10' R31L 1Y (Under Attic or Attic knee wall) Haagng YAM Length Area 8.98 1.08 0.70 0.57 0.40 Attic Tempemutm 150• X e G" X - 0738 0 0 0 Any Roofing Material Cooling 21.42 287 1.68 1.37 0.95 0 ,735. 0 0.-.' 0 - Calling (Sq• Ft) Nora R79 8" R30 10' R31L Ir R56 Calling below Roof Joists Hoeft Wldlh L•e�na-titArea 5.30 1.12 0.75 0.64 0.46 Dark or Bold Color Asphalt Shingle �-J � ® X L . = X 7350 0 0 Dock Carmrtuction Cooling 11.45 1.45 0.94 1 0.71 0.95 735 0 1 0 1 0 Basement Floor 1 WidthArea (2 or More Feet Below Grade) Q X 0 = X Heating r, � shortest side on Grade Linear Ft 0 bend R R-10 It -is Heavy Dry or Light int Sof 112 X Heating 29.9 9.9 7.8 8 9 0 O kmtd 112 R-11 0 N 9 0 • 30 VerticalIrmu13 below No" pen urawl Le Area Space or Garage r�Width L� X=0 c X Heating11.5 1.7 1 0.8 • • • • 0 0 8r•• • 0 •• t • Cooling 19.3 5.1 1.9 1.3 • • 0 0 0 • om WidthArea 0 hard R-0 R R+� Uncondi0ormd crawl Space 0 X= = r' X Heating 7.38 3.35 250 1.97 • • • • or Uncortmonad Basement 0 0 0 • • • 0 • • t • X Cooling 1.92 0.47 0-3L 022 0 0 -a • 0 - Check ff Soni-LOose Ea Fang `' TaitPltY • • • • • • • • • hflW aticrr House Undo 2000 Sq. Ft Over 2000 Sar. Ft • HTD • s • Height km. 49 �•• • • • • r f�Xi CTD e • Fl CFM „„ 15, • ••• •• 0 X rI r• • Number of People People 3 J X " "1230 ..:'. "..'s • • Kitchen Allowance Check Box for for Designer IQtchen (2400 STUH) ❑ 1200 or 0 t t Check Box for % n L 6%8 6% El 67. Supaly Air Duct Leakage and 6% Retum Air Dud a/0 6°!0 Duct $ Reim 9%815% ❑ 9% Supply Air Dud Leakage and 15°!5 Repan Air Dud Leakage 0% LossiGain - Supply 12% 8 24°k ❑ 12% Supply Air Dud Leakage and 24% Return Air Dud Leakage 0% • 24%& 47% ❑ 1 24% Supply Air Dud Leakage and 47% Repan Air Dud Leakage 0% 35%8 70%a 35% Check Bac for Blower Discount 13 Air DuctLeakage and 7076 Reitan Air Dud Leakage 0%Slowu . �111 Discountriormaricedate Mamdaenaws pe 1 Cooling Latent Load reinsCFm Latent Infiltration Gain 0. X r 738 1 X 0 Check Box H Ducts In Latent for Occupants an Uncomiltioned = X Space t� L...� X CFM 1 49 j a t Latent for Duds in Unconditioned space ❑ Otal="dReateiiin -WoF201e1i1%ACttrernfns alone SR Ratio TA[i.L ff, k/,5T E__ " I Certificate of Product Ratings AHRI Certified Reference Number: 5221701 Date: 2/25/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: XC14-030-230-** Indoor Unit Model Number: CBX27UH-036-230*+TDR Manufacturer: LENNOX INDUSTRIES, INC.Fi Trade/Brand name: XC14 SERIES `t Series name:M All in W Manufacturer responsible for the rating of this system combination is LENNOX U� NC. :,. �._; Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 28600 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16.00 IEER Rating (Cooling): 000 FootNote 11 - The AHRI: 2101240 certified EER ratings are.caiculated under the same methodology as the EER ratipgs a*.1 condi4di ms of ISO 5151:2010 and ISO 13253:2011. o • 666.0• Soso 060 • *Soo** • o •• 0000 00 • 6 • . 6666 • •• ••• • ••6.00 60 • 00s • • • • • 0 000 6666•• • • • • • ••• 6666•• • • • • 0 0 •0 • 0000 0 • •••• Ratings followed by an asterisk (') Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which Indicates an Involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated: entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual, AM personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link we make life better - and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which Is listed above, and the Certificate No., which Is listed at bottom right 130378518174909209 ©2014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: C ' RESIDENTIAL LOAD CALCULATIONS Based =25 on RCCA Manual J8ae WWI ���. es ?r'C)cSJiFs� o F4txc7tti'i�; 'a iilP Qur3ft'C,y lnstruetiona: Enter data Into Yeliav fields on[K. All other fields arra reautred tort Grev Holds are calculations. Desion Conditions: Project GROSSMAN Indoor Desim Heeling db 72 Winder 99°w db 60 HTD 22 -7 Address 320 NE 100 STREET Indoor Desi Codin db 75 Summer 11% db - 90 CTD , - is • - & State MIAMI SHORES FL 33138 Indoor Desi Codi RH 50%- Grains 58 -'. Dolly Rw= II.ov Load into Miand, Florida Latitude 25 1 Elevation 11 - .. . .:, �. ��,; - Phone 0 yyt�-�y a fj r :$Tu S'.F�+4S1tTM '-_* "�. �I � r} .. ¢ +F.,`l+�y�:�,y 1t?.L.",a��w. Heat Total Glass Area single Double Tri Jatousie - (Sq. FL) A� L— X Heating 21.56 1232 924 21.56 ;4120 31 Double d -':e i;tai 6'r`1 Jalousie cooling oto - Area (Sq. FL) North X Coding 29 21 18 29 72 Area 45'?'�- -,'. - _- a l:i„'b ”' Check box below NEW X Cooling 61 49 44 61 and to add internal Area 71e t .P;` F �f t + 0 tid ;- R - Sliding Glass Doors Shading. South X Cooling 45 35 31 45 No lrsh�de Area 1 D-"' ❑ SEfSW X Cooling- 73 60 54 73 Area D.�.:,.i R;^ -,_p .-«y,1a _, ..: :_ Iit�i:Y p.... 1 E & W X Cooling 84 70 6484 -.Helftnt d r,.30'Sar,. &- >--,<'<t:0 °rN«a 7 •-se Q.,7_.. 7777t77.p aynu: Doors a Dna Width IEPTI X mX r,7777 Heating Wood 8.58 WoodlAAetil form RAetal 616 7.70 bletalimetal Storm 4.82 0 0 0 X Cooling 7.60 12.5D7.50 12.50 0 0 0 Gross Exposed Wag New Area (Sq. FL) 10 X 154 0 Net Wall FnwwSidbig Area Clradt H R-2 0 Insul R-11 R-13 R•19GR-MExposed Wa01nss ; "'ar �,-:: , X Heating Board Utsulatlon 1.89 1.78 1.39a8 4.09 0 glass and doors Is used. 1, 0 0Wood Studs X Cooling 0 5.39 2.06 1.77 1.12No 0 Board Insulation 1,425 0 0Hel La Area a Insw R-2lnsulR•4braidNet Wog (Above Grade 2' X _ +: Sc-0� �n;� X Heating 12.85 5.92 33&5Concrete Black w/ board Insulation 0 0r No interior finish X Codbng 8.78 4.04 2830 1 C ' 57 E Certificate of Product Ratings AHRI Certified Reference Number: 5698778 Date: 2/25/2014 Product: Split System: Air -Cooled Condensing Unit, Coil with Blower Outdoor Unit Model Number: XC14-036-230= * Indoor Unit Model Number: CBX27UH-036-230*+TDR Manufacturer: LENNOX INDUSTRIES, INC. Trade/Brand name: XC14 SERIES Series name: Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC. Rated as follows In accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 35000 EER Rating (Cooling): 13.20 SEER Rating (Cooling): 16.00 IEER Rating (Cooling): -::; ... :: i it : .' ..' .. . , '•. .. ' g7' 00* FDotNote 11 - The AHRI 210/240 certified EER ratings are Calculated under.the same methodology as the EER ra*s A.T1 cond winmof ISO 51512010 and ISO 13253:2011. • • •••••• •••• ••• • •••••• • • • a • • • •••• •• • ••• • •••••• •• • ••• •• •• •• • ••• • Ratings followed by an asterisk (') Indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which Indicates an Involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed an this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRL This Certificate shall only be used for Individual, personal and confidential reference purposes The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, AM personal and confidential reference. AIR-CONDITIONING, HEATING, CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verity Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above, and the Certificate No., which Is listed at bottom right ©2014 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130378508150312432 I RESIDENTIAL LOAD CALCULATIONS on ACOA Manual J8ae Based mcczs Revised Instructions, Enter data Into Xgaw fields on . All other fields are re trod feM Gray fields are calculations. Design Conditions: Project: GROBSMAN Indoor Desion Heating db I 72Wtraer 89%db SO HTD 22 Address 320 NE 100 STREET Indoor Des1 Coolingdb 75 Summar 1% db 90 CTD 15 C & State MIAMI SHORES, FL. 33136 Indoor Desi n CooO RH ' S0% Grai ns so Daily I Low - Load Into Miami, Florida Lafhude _. 25 Elevation -.-: 11 - r, .+ - - .�, r. _ < Phone 0 a4disRded R�9V[k fUTk�, ;.en r r..r ,dF' '.'A.+ a.. :' '7a1�' �� iso¢ tlrtidarea,l Heat Total Glass (S9. Ft.) Area a 11 P X Heating Birds Double Triple Jalousie 4: Cooling 21.56 12.32 924 21.56 �FHIZ-111111 F, _p 1 i rp :4f , - b W1v(Ra .. coming Total Glass (Sq. FL) and Sliding Glass Doors North Check box below NEW to add Inlennal Shading. South Nolnew dShade ❑ SEISWX E & W Area X Area X Area _ X Area Area X Cooling Cooling Cooling Coaling Cooling SIn& Double Triple Jalousie 29 21 18 29 61 49 44 61 77, 7 45 35 31 4 7,77 8 b:7. - s 70 y. _ x 73 60 54 73. - 84 70 64 84 Doom Nora Width Hai ht Area 2 3 Xa'+:r:�t'.' X X Heating Cooling Wood Storm Metal e-W Storm 8.58 6.16 7.70 4.62 0 42 O 7.50 12.50 7.50 0 1250 0 42 0 0 Groan Exposed Wall (Sq. FL) fd Le Area 18 Net Wall Frema-StcHn Exposed Wag Was all glass and doers Wood Studs No Board Insulation Area JRl;.-tv11-9 iX X Heating Cooling Check H R-2 Board Insulation Is used ® O hard R•11 R•13 R-19 R•21 • + r 4.09 1.89 1.78 1.39 1.32 0 5.39 Sig 0 0 2.06 1.77 1.12 0 0.95 0 519 0 0 0 Net Waft (Above Grade 21 Concrete Block vd board Insubdion No kderior finish Hal Area 16 X 77 n��.12•= - X X Heating Cooling 0 Irnand R-2lrmul R� kmW R-151Tud + ' 12.85 5.92 3.85 1.32 1232 0 0 8.76 4.04 2.63 0 0.90 1232 0 0 0 Net Wall (OBelow Grade Concrete Black w/board Insulation No Interior finish Hal It Len Area X 0 n e ., ti� w 0- a=:-� X Haetlng 0 Irreul R-2 Insul R-4 knsul R-181rtstd r 2.75 1.98 1.5g 0.79 0 1 0 0 0 I \v N«\ aCOO: »I_»«..