PL-13-2721
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-214274 Scheduled Inspection Date: June 18, 2014 Inspector: Diaz, Osvaldo Owner: FREDERICK SUTHERLAND, VERONICA eenr IMA Job Address: 555 NE 93 Street Miami Shores, FL Project: <NONE> Contractor: AROUND THE CLOCK GAS SERVICE Building Department Comments Permit Number: PL -12-13-2721 Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Gas Phone Number (786)260-4901 Parcel Number 1132060141020 Phone: 305-231-3632 NATURAL GAS LINE TO TANK LESS WATER HEATER infractio Passed Comments RANGE AND DRYER I INSPECTOR COMMENTS False Passed Failed Correction Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP-203941. CANCELLED BY INSPECTOR ROLLED OVER ly�'J?- 4 S P i� � � -"� June 17, 2014 For Inspections please call: (305)762-4949 Page 18 of 26 K -.Tell 0 DROP TEST CERTIFICATION Around The Clock Gas Service, Corp. 13117 NW 107 Ave unit 17 Hialeah Gardens, FL. 33o18 Phone: 305-231-3632 ext 301 Fax: 305-231-418o STATE LIC# LPG17356 CLASS# 803 June 12, 2014 To: Whom It May Concern in the City Of Miami Shores Plumbing Department. This is to certify that Around the Clock Gas Service Corp. an authorized Advantage Dealer of Peoples Gas has performed a drop test at the following site and tested all the appliance connections The gas line has been checked to the standards of the 2010 Florida building code, SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING 406.1 GENERAL and properly tested to meet the standards of NFPA 54. The work was performed for: Veronica Molina 555 NE 93 ST Miami Shores F133138 Test Pressure: 8.0 Lock up pressure: 14.2 Operating pressure: 14.0 Test time. 10 Minutes If you should have any questions regarding this matter please do not hesitate to call us. Sincerely, ury Gonzez CEO Around The Clock Gas Service Corp. STATE OF FLORIDA COUNTY OF MIAMI DADE, SWORN TO & SUBSCRIBED BEFORE ME THIS it DAY OF S u av 20 fir9M1 ® KNOWN TOME e4 ` 'MY COM NO E867375 iWG ATURE OF NOTARY PUBLIC 4407,198 045:1 Flor�ServiW torn Miami Shores Village Building Department 10050 N.E2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: PLUMBING FBC 20 Permit No. DEC 0 3 2013 Master Permit No. 2 f % �Z 72,)_ JOB ADDRESS: City: Miami Shores County: Miami Dade zip: -3 S Folio/Parcel#: C) C) (0 l7 Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple Titleholder): Od e a 0 tea` C J ® Pr Phone#• :? G _.� 6 ® —&A Address:- 4-3 city: t -'<o P� L Y". z State: �' �- zip: 3 3 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: " v c ��� 6 P�Phone#• 0; 1-3 G 3�- Address: "�T_ P �) ® t =r City* - N-\ Pt k e ;.- ,,-v �, ww x State: �_=, L_ zip: 3 D Qualifier Name: _ � U 0- �L q) -z- Ar (,e -�,_ Phone#: State Certification or Registration #• L I? G Certificate of Competency #• Contact Phone#: ®-a cA S_ Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $D ®� 0 ' 0 ® �Sonare/Linear Footage of Work: Type of Work: DAddress E4Alteration C`w URepair/Replace DDemolition Description of Work: r, l�R J S - IN A+ r, *,Hr+r,r*,Yskdr�trdr&,4�a*,k&,k�Y�irtie,k�Y*�tr�k4fe�kir&,ha�Y�rF�4r**�kfe��rietit*,t�Y,s�kt ir�Tr,hkk�r�kie,L�Ykr*,raY,L�t�Ar Submittal Fee $-So , Permit Fee $ z 2 T ^ _ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Dame (if applicable) _ Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COM MNCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the. absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. r Signature Signature er or Agnt y Co/tractor The foregoing instrument was acknowledged before me this Z day of at C ,20 ('Z,by_VNA®—� cA ► A a \ ' sl ✓� who is personally known to me or who has produced V450 �� tJ - _--S - 1-6 ( .0 As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: my Y COMMISSION # EE867375 EXPI0ES JTg tWy 22. MJ7_ -) The foregoing instrument was acknowledged before me this "Z— day of 10-t e . 20 (3!, by A, who is personally known to me or who hat produced om. f'., t(A a-.0- � as identification and who did take anon APPROVED BY Plans Examiner Structural Review (Revised3/12/2012)(Revised 07/10/07)(Revised 06/1=009)(Revised 3/15/09) NOTARY PUBLIC: Sign: Print: . w EDVF! yS"tR I SIGN # EE867375 MYIREJJ8Ma 24H7 1407)3 ;i53 NW_ySerWWtin Zoning Clerk Longest Run: 80 Feet Total Load: 272,000 BTU's Type of Gas: Natural Gas Materials: Galvanized Pipe CSST Tubing Poly Plastic Pipe New Outlet (S) 3 New Connection (S) 3 New Outlet 1-1/4" 1/2 - PSI to 7" W. C. Gas New Tankless Water Heater Noritz (NRC830D-N Outdoor Unit) 1" Outlet 1" Shut C 15' DEC 03 New 1/2" Galvanized Pipe strapped to the wall New 1/2" Galvanized Pipe Thru the wall (1 Foot) 20' 2- 1 New 3/4" IPS Poly Plastic Pipe underground 10' New 1-1/4" Galvanized Pipe strapped to the wall New 3/4" Galvanized Pipe Thru the wall New 3/4" - CSST Tubing (25-EHD) strapped to a beam thru the Outlet Shut Off Valve G New 1/2'=Galvanized Pipe strapped to the wall 10' 2525 O --BTU's T- . E 1/2" Shut Off alve L C-:fj T _ 99 O C(;mPj VPt,1CC, VVIfly FEi�F_FiAL rir;,s cT c A'`J ! C.I If ! i Florida Building Code - FUEL GAS 2010 Chart# 402.4 (2) (Galvanized Pipe) Chart # 402.4 (13) (CSST Tubing) Chart # 402.4 (19) (Poly Plastic Pipe) Noritz (NRC830D-N Outdoor Unit) 1/2'- PSI to 7" Gas ISystem Around The Clock Gas Services Installation done in accordance with FBC 2)EDWIN L SILVER LPGO17366 / CCN 02P000369 NFPA 54 $ 58 regulations as w 11 as all loc.k: ' MY COMMISSION # EE887375 13117 N.W. 107th Ave Unit # 17 12121201311:34 Hialeah Gardens, Florida 33018 Amaury Gonzalez "••.•4„ FacPl 7 nk--s./4n6\ 944_4&47 / C-tv-/4n6\ 944-14on 1�k AAArs - 66X. AI 4r Qfree wwr .ter. Florida Building Code - FUEL GAS 2010 Chart # 402.4 (2) (Galvanized Pipe) New Dryer (30") Chart # 402.4 (13) (CSST Tubing) 25.000 BTU's Chart # 402.4 (19) (Poly Plastic Pipe) 1/2" Outlet Noritz (NRC83OD-N Outdoor Unit) 1/2" Shut Off Val 1/2 - PSI to 7" Gas System 20' 1 16' 1�1\' New 3/4" IPS Poly Plastic Pipe 2 - 3/4" IPS Poly Plastic Risers 20' underground 0' INew Meter For Equipment I New Outlet 1-1/4" 1/2 - PSI to 7" W. C. Gas Svstem New Tankless Water Heater Noritz (NRC83OD-N Outdoor Unit) 1" Outlet 1" Shut Off Valve New Range (36") 3/4" Outlet 5' 3/4" Shut Off Valve Front of House N O R T H Around The Clock Gas Services Installation done in accordance with FBC 20In LPGO17356 / CCN 02P000359 NFPA 54 & 58 regulations as 11 as all Iota EDWIN L SILVER 13117 N.W. 107th Ave Unit # 17 12/2/201311:34 MYC MISSI W7375 Hialeah Gardens, Florida 33018 Amaury Gonzalez PIRES.ianua 7 Phone:(305) 231-36321 Fax:(305) 231-4180 Job Address: 655 9 d Str et (407�36i0153 0 NORITZ Model NRC83 Series Residential Condensing Tankless Water Heater Specification Sheet • Standard Input - gas consumption ranges from 16,000 BTUh to 157,000 BTUh • Capacity Range - flow rates from OS gpm up to 8.3 gpm • Compact Design - ANSI Z21.10.3/CSA 4.3 certified design that can be wall -mounted indoors or outdoors • Durable Steel Casing with Polyester Coating • Heat Exchanger - manufactured with commercial grade copper, 25% thicker piping than standard models • Venting Options - available as an Outdoor (requires no venting) or indoor Direct Vent (-DV) model which includes special plastic flue adapters that are compatible with both 3"or4"Schedule 40 and 80 PVC/CPVC pipe. The DV model can also be converted to a non -direct vent (SV) model with the use of a Conversion Kit (#SWCK-3) • Direct Electronic Ignition • Quick -Connect - two identical units can be linked together by using the optional Quick Connect Cord (#QC -2) for twice the hot water capacity • Energy Factor - 0.92 (NG) 0.92 (LP) •Thermal Efficiency- fully condensing, 93% efficient for use with natural gas or propane • Temperature Controls - includes remote thermostat that can precisely adjust the output temperature from 100"F to 140"F with the capability to display temperatures in both "C and •F • Power Cord Installation Kit - 6' power cord is included with -DV models only • Safety Devices - Flame Sensor, Overheat Prevention Device, Lightning Protection Device, Freeze Protection, Condensate Overfill • Additional Features -Temperature Lockout, High Elevation Adjustment, Condensate Overflow Monitoring System, Service Reminder Function • 12 -Year's Limited Heat Exchanger Warranty for Residential Use • S -Year Limited Parts Warranty • Approvals - CSA, UPC**, NSF, Low NOx Approved by SCAQMD [<14ng/J or 20ppm], Suitable for Installation in a Manufactured (Mobile) Home*"* OD Model Model NRC83- ❑ OD (Outdoor Vent) ❑ DV (Direct Vent) DV Model Accessories ❑ Horizontal Hood Termination (#PVT -HL) ❑ 3"PVCTermination (#VK3-H-PVC) ❑ Birdscreen for a"PVC(CPVC(#VT3-PVCS) ❑ Birdscreen for 4"PVUCPVC(#VT4-PVCS) ❑ Condensate Neutralizer (#NC -1) ❑ Isolation Valves (#IK -WV -200-1) ❑ Pipe Cover (#PC -35) ❑ Quick Connect Cord (#QC -2) ❑ SV Conversion Kit (#SV -CK -3) "Heat Exchanger warranty is maintained at 12 years or 6500 operational hours, whichever occurs first, when used in a single family dwelling in conjunction with a controlled recirculation system (an aquastat being the minimum pump control requirement) in accordance with the Installation Manual. Refer to the Noritz Limited Warrantyforcomplete coverage details •*This product complies with California AB 1953 Low Lead Law and Section 1417(d) ofthe Safe Drinking WaterAct I Manufactured (Mobile) Home approval is valid for OD and DV models only NORITZ AMERICA CORPORATION 11160 Grace Avenue, Fountain Valley, CA 92708 Tel.1-866-7NORITZ www.noritz.com Dimensions Flow Rates Temperature Rise (°F) 30 40 45 50 60 70 80 90 100 Flow Rate 3/4" Gas Inlet 3/4" Condensate Drain 1/2" Supply (GPM) 8.3 7.3 6.5 5.8 4.9 4.2 3.7 3.2 2.9 Pressure Loss 35 30 25 20 J 7 15 a 10 5 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 Flow Rate (gpm) Specifications Model Name NRC83-OD NRC83-DV Weight 57 (pounds) 58 (pounds) Water Holding Capacity 05 Gallon 0.8 L) Water Inlet 3/4" Connection Sizes Hot Water Outlet 3/4" Gas Inlet 3/4" Condensate Drain 1/2" Supply 120VAC MHz), less than 4 amperes Power Consumption NG:51W LP:54W Freeze Prevention 203W NG:58W LP:64W Freeze Prevention 213W Freeze Protection Outdoor: -4°F Indoor. -30°F Temperature Settings °F Mode 100-1407 (in 5°F Intervals) (9 Options) °C Mode 37 -WC (In 1°C Intervals), 50, 55, 60°C (in 5°C intervals) (15 Options) Default Temperature Options °F Mode 120,130,140°F (Default is 120°F) °C Mode 50, 55, 60°C (Default is 50°C) Noritz America reserves the right to discontinue, or change at anytime, the designs and/or specifications of Its products without notice. Rev. 11 /13 Clearance Requirements from Vent Terminations to Building Openings * All clearance requirements are In accordance with ANSI 221.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. Vent Terminal Area Where Terminal ® Air Supply Inlet ® is Not Permitted ()= indicates clearances required in Canada *Maintain clearances in accordance with local installation codes and the requirements of the gas supplier ***A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. , ****Permitted only if veranda,porch,deck cr balcony is fully open on a minimum of two sides beneath the floor. Clearance Indoor Installation Outdoor installation See .9 See .9 A= Above grade, veranda, porch, deck, 12'(12') 12'(12') or balcony V below or to the side of B- Window or door that may be opened opening, or 1' above opening 12" (36") (36") C= Permanently closed window • Vertical clearance to ventilated soffit D= located above the terminal within a horizontal distance of 2 feet from the center of the terminal E= Unventilated soffit F= Outside comer G= Insi a comer H= Each side of center rine extended 3' within a height 15 above T within a height 15 above above meter/regulator assembly meter/regulator assembly meter/regulator assembly 1= Service regulator vent outlet T V Nonmechanical air supply inlet or 4' below or to the side of J= combustion air Inlet to any other opening, or V above opening 12'(36') appliance 36" K= Mechanical air supply inlet T above if within 10' 6' 3' above if within 10' 6 L= Above paved sidewalk or paved (7, ) T driveway located on public property M= Under veranda, porch, deck, or( 12"- Canada Only"*'') (12% Canada Only') balcony ()= indicates clearances required in Canada *Maintain clearances in accordance with local installation codes and the requirements of the gas supplier ***A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings. , ****Permitted only if veranda,porch,deck cr balcony is fully open on a minimum of two sides beneath the floor. [Clearance Requirements from Vent Terminations to Building Openings All clearance requirements are in accordance with ANSI 221.10.3 and the National Fuel Gas Code, ANSI Z223.1 and in Canada, in accordance with NSCNGPIC. * For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 36". To forced air inlets: 6'. These clearance requirements hold true for all of the above situations: Indoor, Outdoor w/vent cap. Maintain the following clearances to any Illustration opening in any building: • 4' below, 4' horizontally from, or 1' above any door, operable window, or gravity air ❑ ❑ i inlet into any building. 3' above any forced air inlet within 10'. m c c ��cmc 5— 4' .N ' 1.2 c� y 1' m ° 3' U c • 1' below, 1' horizontally from, or 1' above any door, operable window, or gravity air inlet into any building. U 3' above any forced air inlet within 10'. m� m • For outdoor installation, use the outdoor _ to vent cap. ® m c If it is necessary to vent above the roof line in an outdoor installation, also use the base of the vent cap for rain protection. 1' 1 1' 0 O 3' m0 © O U m Q Q CD (Noritz vent cap) * For Installations in Canada, clearances are as follows: To windows, doors, & gravity air inlets: 36". To forced air inlets: 6'. These clearance requirements hold true for all of the above situations: Indoor, Outdoor w/vent cap.