RF-14-2133Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-222070
Scheduled Inspection Date: October 22, 2014
Inspector: Rodriguez, Jorge
Owner: LYTLE, JAMES & JOYCE
Job Address: 429 NE 101 Street
Miami Shores, FL 33138-3163
Project: <NONE>
Permit Number: RF -9-14-2133
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Flat
Phone Number (305)546-2376
Parcel Number 1132060170640
Contractor: RHI CONSTRUCTION INC Phone: (954)295-4637
tiuuamg uepartment comments
RE -ROOF FLAT ONLY
INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-221729. CREATED AS
REINSPECTION FOR INSP-220614. Missing uplift test
Failed
Correction ❑
Needed
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
-Missing caulking on the drypins.
-Need to open shutter to allow inspection of the flashing around the opening.
October 21, 2014 For Inspections please call: (305)762-4949 Page 25 of 29
Miami Shores Village
g p
0\y Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795-2204 Fax: (305) 756-8972
INSPECTION LINE PHONE NUMBER: (305) 762-4949
BUILDING
PERMIT APPLICATION
❑BUILDING ❑ ELECTRIC ROOFING
❑PLUMBING ❑ MECHANICAL. ❑PUBLICWORKS
SEP 3 0 014
FBC 2013
Master Permit N.o. 8 cj� ® Z�
Sub Permit No.
0 REVISION ❑ EXTENSION [:] RENEWAL
❑ CHANGE OF ❑ CANCELLATION ❑ SHOP
CONTRACTOR DRAWINGS
JOB ADDRESS: 112q 41r- //? s�
City: Miami Shores County Miami Dade Zip: '33 139
n• A A S_ _ I A. • � 1
Folio/Parcel#: 11 Sd %j%0 — Q 1 i
Occupancy Type: Load:
OWNER: Name (Fee Simple Titleholder):
Address: 1
City:ffilaml shofts
Tenant/Lessee Name:
Email: T,
CONTRACTOR: Company Name:
Address:llsb h
City: V
Qualifier Name: �2VGn
State Certification or Registration #:
DESIGNER: Architect/Engineer: 1
Address:
Value of Work for this Permit:
Type of Work: ❑ Addition
Description of Work:
pw %j Is the Building Historically Designated: Yes NO
Construction Type: Flood Zone: BFE: FFE:
UU.
❑ Alteration
State: rl Zip:
rtificate of Competency #:
City: State: /Zip:
Square/Linear Footage of Work:
W _ ❑ Repair/Replace ❑ Demolition
Specify color of color thru tile: A A (AA W U
Submittal Fee Permit Fee $
Scanning Fee $ Radon Fee $
Technology Fee $ Training/Education Fee $ _
Structural Reviews $
(Revised02/24/2014)
w
CCF $ CO/CC $
DBPR $ Notary $
Double Fee $
Bond $
TOTAL FEE NOW DUE $ ® 4a 5D a5D
Bonding Company's Name (if applicable)
',onding Company's Address
City State
Mortgage Lender's Name (if applicable) _
Mortgage Lender's Address
City
State
Zip
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
f first inspection which occur seven (7) days after the building permit is issued. In the absence of such posted notice, the
e '
inspon 1 not be approved ak(einspection fee will be charged.
Signatu
OWNER or
The regoing instru ent was ac cnowledged before me this
A44 mks d.
p day ofL41111171A20, by
who is personally known to
me or who has produced K OL c.Vi O-Hf-1-50.301-0as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal:
1407) 39"1
APPROVED BY
(Revised02/24/2014)
STEPHANIE NATALIE W
MY COMMISSION # EE.SM,
EXPIRES March 06, 2017
4
Signature
CONTRACTOR
The foregoing instruent was acknowledged before me this
__C 1iL day of n 20 , by
_yA g"n USom,T 1 , who is personally known to
,.2e or who has produced as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:j d
Print:ftn
• �; STEPHANIE NATALIE BONUA
Seal: A. My COMMISSION P EE880981
EXPIRES March 06, 2017
Plans Examiner Zoning
Structural Review Clerk
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
CONTRACTORS' REGISTRATION
IF CONTRACTOR IS A FLORIDA STATE CERTIFIED CONTRACTOR:
A.V COPY OF QUALIFIER'S STATE LICENCES
B. � COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF LIABILITY INSURANCE*
D. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER Affidavit)
IF CONTRACTOR HAS A MIAMI DADE COUNTY CERTIFICATE OF COMPETENCY:
A. COPY OF CERTIFICE OF COMPETENCY OF QUALIFIER
B. COPY OF LOCAL BUSINESS TAX RECEIPT
C. COPY OF STATE REGISTERED CONTRACTOR LICENSE OR MIAMI DADE COUNTY MUNICIPAL
CONTRACTOR'S TAX RECEIPT.
D. COPY OF LIABILITY INSURACE*
E. COPY OF WORKERS COMPENSATION INSURANCE*
(Workers Compensation EXEMPTION must have NOTICE TO OWNER Affidavit)
*YOUR INSURANCE COMPANY MUST ISSUE A CERTIFICATE AS FOLLOW:
Certificate Holder:
MIAMI SHORES VILLAGE BLDG DEPT
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
Certificate must specify the description of operations or contractor license number.
BUSINESS NAME:
BUSINESS ADDRESS: 1150 NW Is r i, AVSJS CITYgllt7 STATE - ZIP Ott
BUSINESS PHONE: ( ) aqo-399. FAX NUMBER (954) 921- 0\140
CELLPHONE(994) _o� _IJ -y�3� QUALIFIER'S NAME: RU -1011) Nom ori
QUALIFIER'S LIC NUMBER: ---CC CI 328Q011
RICK SCOTT, GOVERNOR KEN LAWSON, SECRETARY
STATE OF FLORIDA
DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION
CONSTRUCTION -INDUSTRY LICENSING BOARD
�
CCC1328984
4 r'
Y
The ROOFING CONTRACTOR
Named below IS CERTIFIED
Under the provisions of Chapter 489 FS.
Expiration date: AUG 31, 2016
NEMATJ, —RM, AN ANARAKI
RHI CQNSTRUCTION.1PMt
470-y W..100T1-I TVAAA't
CORAL Si'RNfS ��:'33078
ISSUED: 07/09/2014 DISPLAY AS REQUIRED BY LAW SEQ#
L1407090000998
CERTIFICATE OF LIABILITY INSURANCEF1010812014
A✓
DATE(MMroDIYYYY)
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES
BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED
REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the pollcy(les) must be endorsed. If SUBROGATION IS WAIVED, subject to
the terms and conditions ofthe policy, certain policies may require an endorsement. A statement on this certificate does notconfer rights to the
certificate holder In lieu of such endorsement(s).
PRODUCER
REEL INSURANCE AGENCY
DIBIAI COVERALL INSURANCE
5800 W. ATLANTIC BLVD.
MARGATE FL 33063
CONTACT IBET LEMUS
PHONE954 956-0006 Fax 954 956.0555
-MAIL ILEMUSOCOVEMLINSUPANCE.NET
N u AFFORDING COVERAGE C p
INSURER A: UNITED SPECIALTY INSURANCE COMPANY 12537
INSURED
RHI CONSTRUCTION INC.
1750 NW 15TH. AVENUE
SUITE # 515
POMPANO BEACH FL 33069
INSURER 8:
I RRC
INSURER D:
INSURER E:
INSURER F:
COVERAGES CERTIFICATE NUMBER: REVISION NUMBER:
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD
INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACTOR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS,
EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
IN SR
TYPE OF INSURANCE
DL
UBR
POLICY NUMBER
POLICY EFF
POLICY EXP
LIMITS
GENERAL LIABILITY
EACH OCCURRENCE s2,000,000
DAMAGE TO RENTED $100,000
MED EXP (Any one $5,000
A
X COMMERCIAL GENERAL LIABILITY
CLAIMS -MADE XI OCCUR
USA4066702
10108/2014
101081201.5
PERSONAL & ADV INJURY $ 2,000,000.
GENERAL AGGREGATE 0,000,000
GENML AGGREGATE LIMIT APPLIES PER;
PRODUCTS - COMP/OP AGG s3,000,000
$
POLICY PRO- 7LOC
JFrT
AUTOMOBILE LIABILITY
COMBINED SINGLE LIMIT
BODILY INJURY (Per person) $
ANY AUTO
BODILY INJURY (Per accident) $
ALL OWNED SCHEDULED
AUTOS NO -OWNED
HIRED AUTOS AUTOS
PROPERTY DAMAGE $
�Per accident)
$
UMBRELLA LIAR
XOCCUR
EACH OCCURRENCE 5,000,000
AGGREGATE 51000,000
A
X
EXCESS LIAR
CLAIMS -MADE
USA -4004666
1011512014
10115/2015
DED I I RETENTI
$
WORKERS COMPENSATION
WC STATU- OTH-
AND EMPLOYERS' LIABILITY
ANY PROPRIETOR/PARTNERIEXECUTIVED
E.L. EACH ACCIDENT $
E.L. DISEASE - EA EMPLOYEE
OFFICERIMEMBEREXCLUDED? I„_,_J
(Mandatory In NH)
N / A
E.L.DISEASE -POLICY LIMIT
If yes, describe under
RIPTI F PERAT below
DESCRIPTION OF OPERATIONS! LOCATIONS / VEHICLES (Attach ACORD 101, Additional Remarks Schedule, if more space is requlred)
SIDING INSTALLATION, ROOFING • RESIDENTIALICOMMERCIAL THIS INCLUDES HOT TAR & TORCHDOWN, CARPENTRY
MIAMI SHORES BUILDING DEPT
10050 NE 2ND AVENUE
MIAMI SHORES FL 33138
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTJCE WILL BE DELIVERED IN
ACCORDANCE W FCf VE POLICY PROVISIO '
AUTHORIZED
0 ACORD
ACORD 25 (2010105) The ACORD name and logo are registered marks of ACORD
reserved.
ACORD CERTIFICATE OF LIABILITY INSURANCECAM(MIIIIII)OMM
IN
09134!2014
PRODUCER
REEL INSURANCE AGENCY
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION
ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE
5800 W. ATLANTIC BLVD.
HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR
ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW.
MARGATE FL 33063
SITS
PH 954 956.0006 FX 954 956.0555
INSURERS AFFORDING COVERAGE NAIC #
INSURED RHI CONSTRUCTION INC.
1750 NW 15 AVE, STE 515
POMPANO BEACH, FL. 33069
w$uRERA: UNITED SPECIALTY INSURANCE COMPANY
INSURER -
INSURER C:
INSURER D:
A
INSURER E:
X COMMERCIAL GENERAL LABILITY
CLAW MADE 7 OCCUR
SCJ
THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POUCY PERIOD INDICATED. NOTWITHSTANDING
ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR
MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH
POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
INSR
AODL
POLICY NUMBER
POLICY EFFECTIVE
POLICY EXPIRATION
SITS
EACH OCCURRENCE s2,000000
GENERAL LIABILITY
A
X COMMERCIAL GENERAL LABILITY
CLAW MADE 7 OCCUR
USA4026169
10/0812013
10108/2014
DAMAGE RENTED 10 000
MED EXP r one erson 5 000
PERSONAL 8 ADV INJURY s2,000,000
GENERAL AGGREGATE 3 000 000
GENT_ AGGREGATE LIMIT APPLIES PER:
PRODUCTS - COMP/OP AGG s 3.000.000
Ra LOC
POLICY PIr
AUTOMOBILE
LIABILITY
AUTO
COMBINEDSINGLE LIMIT 8
(Ea t
BODILY INJURY $
(Per Person)
ALL OWNED AUTOS
SCHEDULED AUTOS
BODILY INJURY
(Per ecatdent) $
HIRED AUTOS
NON -OWNED AUTOS
PROPERTYDAMAGE $
(Per acddent)
GARAGE LIABILITY
AUTO ONLY - EA ACCIDENT
OTHER THAN EA ACC
ANY AUTO
AUTO ONLY: AGG
A
EXCESSIUMBREI LA LIABILITY
X OCCUR CLAIMS MADE
USA OM68
10/1512013
10115014
EACH OCCURRENCE $5,000,000
-AGGREGATE $5,00,000
DEDUCna-
RETENTION
WORKERS COMPENSATION AND
WC -STA - OTH-
EEL
EMPLOYERS' LIABILITY
-
ANY PROPRIETOR/PARTNERIEXECUTIVE
OFFICERIMEMBER EXCLUDED?
H deswlbe lender
E.L. EACH ACCIDENT
E.1m DISEASE - EA EMPLOYE
E.L. DISEASE - POLICY LIMIT
R 1
OTHER
DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT f SPECIAL PROVISIONS
SIDING INSTALLATION,ROOFING RESIDENTALICOMMERCIAL, CARPENTRY, INCLUDES HOT TAR & TORCHDOWN
MIAMI SHORES VILLAGE BLDG DEPARTMENT
10050 NE 2ND AVE
MIAMI SHORES, FL 33138
ACORD 25 (2001108)
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION
DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 10 DAYS WRITTEN
NOTICE TO THE CERTIfl - HOLDER NAMED TO THEhW, BUT FAILURE TO DO SO SHALL
IMPOSE NO OBUGATIONVpR—AwiLrTy OF ANY KIND CPO) TME INSURER, ITS AGENTS OR
..
1989
CERTIFICATE OF LIABILITY INSURANCE
Date
9/30/2014
Producer: Lion Insurance Company
2739 U.S. Highway 19 N.
This Certificate is issued as a matter of Information only and confers no
rights upon the Certificate Holder. This Certificate does not amend, extend
Holiday, FL 34691
or alter the coverage afforded by the policies below,
Insurers Affording Coverage NAIC #
(727) 938-5562
Insured: South East Personnel Leasing, Inc. & Subsidiaries
Insurer A: Lion Insurance Company 11075
Insurer B:
2739 U.S. Highway 19 N.
Insurer C:
Holiday, FL 34691
Insurer D:
Insurer E:
Coverages
The policies of insurance listed below have been issued to the insured named above for the policy period indicated. Notwit Stan Ing any requirement, term or condition o any contract or other document
with respect to which this certificate may be issued or may pertain, the insurance afforded by the policies described herein is subject to all the terms, exclusions, and conditions of such policies. Aggregate
limits shown may have been reduced by paid claims.
INSR
LTR
ADDL
INSRD
Type of Insurance
I
Policy Number
Policy Effective
Date
Policy Expiration
Date
Limits
(MM/DD/YY)
(MM/DD/YY)
GENERAL LIABILITY
Each occurrence
Commercial General Liability
Claims Made 11 Occur
Damage to rented premises (EA
occurrence)
$
Med Exp
Personal Adv Injury
General aggregate limit applies per:
General Aggregate
Policy ❑ Project ❑ LOC
Products - Comp/Op Agg
AUTOMOBILE LIABILITY
Combined Single Limit
Any Auto
(EA Accident)
$
Bodily Injury
All Owned Autos
Scheduled Autos
(Per Person)
Bodily Injury
Hired Autos
Non -Owned Autos
(Per Accident)
Property Damage
(Per Accident)
EXCESS/UMBRELLA
LIABILITY
Each Occurrence
Occur ❑ Claims Made
Aggregate
Deductible
A
Workers Compensation and
WC 71949
01/01/2014
01/01/2015
X
I wC Stetu-
OTH-
Employers' Liability
tory Limits
ER
E.L. Each Accident
$1,000,000
Any proprietor/partner/executive officer/member
excluded? NO
If Yes, describe under special provisions below.
E.L. Disease - Ea Employee
$1.000,000
E.L. Disease - Policy Limits
$1,0oo,000
Other
Lion Insurance Company is A.M. Best Company rated A- (Excellent). AMB # 12616
Descriptions of Operations/Locations/Vehicies/Exclusions added by Endorsement/Special Provisions: Client ID: 80-65-815
Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company":
RHI Construction, Inc.
Coverage only applies to injuries incurred by South East Personnel Leasing, Inc. & Subsidiaries active employee(s;, while working in: FL.
Coverage does not apply to statutory employee(s) or independent contractor(s) of the Client Company or any other entity.
A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562.
Project Name:
ISSUE 09-30-14 (EP)
in Date 10 28 2010
CERTIFICATE HOLDER CANCELLATION
MIAMI SHORES VILLAGE BUILDING DEPT.
Should any of the above described policies be cancelled before the expiration date thereof, the Issuing
insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to
do so shall impose no obligation or liability of any kind upon the insurer, its agents or representatives.
10050 NE 2ND AVE.
MIAMI SHORES, FL 33138
E 0 %
BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT
115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000
VALID OCTOBER 1, 2014 THROUGH SEPTEMBER 30, 2015
DBA:
Business Name: RHI CONSTRUCTION INC
Owner Name: REZVAN A NEMATI
Business Location: 1750 NW 15 AVE # 515
POMPANO BEACH
Business Phone: 954-290-3992
R@ceipt#:ROOFING/SHEET METAL CONTRACTOR
Business Ty (ROOFING CONTRACTOR)
Business Opened:10/02/2009
State/County/Cert/Reg:CCC13 2 8 9 84
Exemption Code:
Rooms Seats Employees Machines Professionals
1
For Vending Business only
Number of Machlnww
Tax Amount
Transfer Fee
NSF Fee
Penalty
Prior Years
Collection Cost
Total Paid
27.00
0.00 1
0.00
0.00
0.00
0.00
27.00
THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS
THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is
non -regulatory in nature. You must meet all County and/or Municipality planning
WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when
the business is sold, business name has changed or you have moved the
business location. This receipt does not indicate that the business is legal or that
it is In compliance with State or local laws and regulations.
Mailing Address:
RHI CONSTRUCTION INC Receipt #30A-13-00011913
4788 NW 100 TER Paid 08/15/2014 27.00
CORAL SPRINGS, FL 33076
2014 -2015
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
October 06, 2014
Permit No: RF -14-2133
Building Critique
1" REVIEW: 09/30/2014
1. BUR 150 is not an acceptable system in Miami Dade County, please provide a
low slope roof system with an approve notice of acceptance from the State of
Florida or Miami Dade County.
2. Provide detail of the connection with the slope roof.
3. Provide class A fire rated system.
Plan review is not complete, when all items above are corrected, we will do a complete
plan review.
If any sheets are voided, remove them from the plans and replace with new revised
sheets and include one set of voided sheets in the re -submittal drawings.
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204 CITY
Fax: (305) 756.8972
October 06, 2014
Permit No: RF -14-2133 C, OPY
Building Critique
1" REVIEW: 09/30/2014
1. BUR 150 is not an acceptable system in Miami Dade County, please provide a
low slope roof system with an approve notice of acceptance from the State of
Florida or Miami Dade County.
2. Provide detail of the connection with the slope roof.
3. Provide class A fire rated system.
Plan review is not complete, when all items above are corrected, we will do a complete
plan review.
If any sheets are voided, remove them from the plans and replace with new revised
sheets and include one set of voided sheets in the re -submittal drawings.
ROOF ASsEmnif-9 AND ROOFTOP STRUCTURES
Florida -Building Code Ear
High Velocity Hurricane Zone -Uniform Perrnti
Miami Shores Village
APPROVED
BY
DATE
I
ZONING DEPT
BLDG DEPT
•
an zVUf
RYAJcEonaYT T P
. 9MPLIANCE WITH ALL FEDERAL
04
TATE AND CLJNTY RULES AND REGULATIONS
Sticuan A imenstal In -
Master Permit No. Process No.
Contractor's Name IM Con&ilwwon inc- up
Job Ad
0OF CATEG
rVA
ift
TO ❑ Low Slope 0 Mechanically Fastened Tile D Mortar/Adhesive S
Q Asphaltic 0 Metal Panel/Shingles 0 Wood Shingles/Sh
Shingles
Prescriptive BUR -RAS 160
ROOF TYPE
Cl NewRoof V1t;011r,0,ofhng ❑ Recovering 1~I Repair-! Ei Ma"e,"ince
ROOF SYSTEM
INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF)
Won B (Roof Plan)
;;ketch Roof Plan: Iflu"rate all, levels and[ sections, olof drains, scuppers, overflow scuppers and overflow drains.
Include dfmenslonsof seottWtIsLand-levels, clearly identify dimensions of elevated pre"urezo "andlocationof
parapets,
ar
•
Osseo*
10'
•
s o
06 lee
0 low
00
00000
0 a
*000,1
*sees
0*00
0 0 00
ee 00
0
0
•
0
000900
0 0
:0000000.00.
0000
:
:FJ.ORIDA:8,0ILI:)iN43--cQ0E —"BURMING
I
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
Florl`da Building Code Edition 2007
High-Valocity+ Hurricane Zone Uniform Permit Application form.
Section G (Low Slops Application) Surfacing: Granules
Flli to specific roof assembly components
and Identify; manufacturer
(if a component is not used, identify as "NA")
tem M,onofacturep' G ,
Product Approval No;: 13 6'6
Design Wind'Pressures, From RAS 128 or Calculations:
Pmaxl51.4 Pmax2:86.2 Pmax3:129.7
Max. Design Pressure,.from the. specific Product
Approval system: sx
Deck; CDX plywood
Type:
Gaugerrhickness:
slopm-1 /4'1 : X12 r
Anchor/Base Sheet 4 No. of Ply(s): 1 Ply 75#
Anchor/Basis Sheet' Fastoner[Bonding Mattel:
N*Wd Tabs
Insulation Base Layer: N/A
Base Insulation Size and Thickness: N/A
Base insulation Fastener/Bonding-Material
WA
Top Insulation Layer: NSA
Top insulation Size and Thickness: N/A
Top Insulation FastenerlSonding Material:
NA
Base Sheat(s) & No. of Ply(s): NIA
Base Sheet Fastener/Bonding Material:
WA
Ply Sheet(s) & No. of Ply(s): 2 ply- Glass Ply 4
Pyr_ dt Faatonerla nding Material:
HoCasphattType•4
`rop Ply: Mineral Surfaced Gap Sheet
Top Ply Fastener/Bonding Material:
Hot.AspMt Typed
FLORIDA BUILDING CODE—BUILDING
Fastener Spacing for Anchor/Base Sheet Attachment:
Field: 9 " oc @ Lap, # Rows 2 @ 9 " oc
Perimeterr. � „ oa � Lap, # ftv g� o 5 oc
Corner: 4_ " oc @ Lap, # Rows 3 @ 4 " oc
Number of Fasteners Per Insulation Board:
Field N/A Perimeter NIA Corner N/A
Illustrate Components Noted and DeWs as
Applicable:
Woodblocking, Gutter, Edge Termination, Stripping, Flashing,
Continuous Cleat, Cant Strip, Base Flashing, Counter -
Flashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material Thickness, Fastener
Type, Fastener Spacing or Submit
i
ET
I
i ,nerw) s-r-c-ceo( Gq'
n
Parapet
Height
�io vl ti �°�lra5•
1-1
j/ C Cif- r5lwoojl
Mean
Roof
Height
T. -
FLORIDA
.
= RHI m
Construction Inc.
CCC 1328984 - CGC 1505741
1750 NW 15th Ave # 515
Pompano Beach FL 33069
Ph.: (954) 290-3992 Fax: (954) 827-0160 Web: WWW.RHIRoofing.com Email: RHIINC@bellsouth.net
Flat roof to tile roof tie in detail
Back Nail Mineral Cap sheet 6" OC followed by roofing mastic and felt
Existing tile underlayment
Mineral Surfaced Cao
16" wide vallev metal primed & set In roofing
2 aly of ply 4 in hot type
%.ria haiP Shept
Wood deck
Notes:
-Remove 2 lines of concrete tile
-complete tie In as above
-Re Install 2 existing lines of tiles with roof tile adhesive
Page 1 of 1
A
AC132 ENGINEERING INC
Testing and Engineering Services
Certificate of Authorization - C.A. # 8131
16821 SW 1 Street, Pembroke Pines, FL 33027
Engineering Calculations
FLORIDA BUILDING CODE 2010
CALCULATIONS FOR ANCHOR OR BASE SHEET ATTACHMENT
BASED ON ROOFING APPLICATION STANDARD (RAS) No. 117
(New Construction/Reroof Applications)
PROJECT NAME: RHI Construction
This calculations is for a Flat Section of a property located at:
429 NW 101 Street,Miami Shores
Given by: RHI Construction
Flat Roof Section Area is: 8.87 Squares
Building with a roof mean height less than
Base Sheet Lap 4 Inches
Wind Uplift Pressures from Permit Application:
Field Area -52.5 psf
Perimeter Area -52.5 psf
Comer Area -52.5 psf
12 feet
SLOPE ( Equal or Lower)
1/2" in 12"
Wind Uplift Pressures from RAS No. 128 (See FBC) EXPOSURE D
Field Area -51.4 psf Wind Speed 175 mph
Perimeter Area -86.2 psf
Comer Area -129.7 psf
FASTENERS BY NOA - NOA # 13-0424.09 Page 15 of 17
Fastener Option attach base sheet usung 11 ga annular ring shank nails spacing of
9"o.c. @ 4" lap and 9" o.c. in two equally spaced staggered rows in the center of the sheet
Maximum Design Pressure by NOA: -52.5 psf
Fig
ACB2 ENGINEERING INC.
Testing and Engineering Services
CALCULATIONS FOR BASE SHEET
Given:
Width of Sheet is: 36 inches (Information by Roofer)
Side Lap Width is: 4 Inches (Information by Roofer)
A. CALCULATE IMDTH OF SHEET FOR ONE NET SQUARE (100 f,2)
1... Net Width of ShW M.
Net Wdth(ft) = (Sheet Width) - (Side Lap Width) / 12
Net Width (ft) = 2.666667 ft OR
32 inches
2. Net Length to Make One Square (10() Square Feet) .
Net Length = (100 ft2)/Net Width
Net Length = 37.5 ,feet
B. DETERMINE THE NUMBER OF FASTENERS PER SQUARE
General Equation
0 Fastener/A) x (12 in./ft) x ((g/row) x (C/square) = D
Where
A= Specified Fastener spacing LAP
A2=Specified Fastener spacing (FIELD/ROW)
B --Net Length (in feet) to make one square
C --number of rows having spacing A (LAP)
C2=number of rows having spacing A2 (FIELD/ROW)
D= number of fasteners per square
SIDE LAP ROW.
50 "=D" Fasteners/Square
CENTER ROW.-
100
OW:100 "=D" FastenerslSquare
Total Number of Fasteners per Square (every 100 ft2) _
TOTAL SQUARE FEET PER FASTENER
0.666667 Squame Feet
per Fastener
9 Indies
9 Inches
37.5 feet
1 Rows
2 Rows
150
. �a
C
k
ACG2 ENGINEERING INC
Testing and Engineering Services
DETERMINE THE FASTENER VALUE
Given:
Calculated Square Feet per Fastener = 0.666667 faFastenff
MaAmum Design Pressure From NOA 52.5 psf
GENERAL EQUATION
Fy = Fastener Value
Fy = (max design Pressure) x (square feet per fasteners)
Fy = 35.00002 Ibf
DETERMINE ANCHOR/BASE SHEET SPACING
TO MEET PRESSURE
GENERAL EQUATION
FS = (Fy x 144)/ (P x RS)
FS = fastener spacing (inches)
Fy = fastener value (ibf)
P = max design pressure (psf)
RS = row spacing (inches)
Note:
Row spacing (RS) is the Net Width of Sheet divided by number of ram
The Net Wdth is the width of base sheet less the side lap distance
Total Number of rows from NOA = 3 Fastener Rows
From Previous Calculations:
The net width is 32 inches
Therefore Row Spacing = 10.66667 inches
Wind UPldit Pressures from RAS 128: Exposure D
Field Area 51.4 psf Wind Speed 175 mph
Perimeter Area 85.2 psf
Comer Area 129.7 psf
CONCLUSIONSIRECOMMENDATIONS
A. FASTENER SPACING FOR PERIMETER AREA
FS = 5.481441 inches
USE MAXIMUM 5 INCHES SPACING (Fractions are roundel down per 2010 FBC)
Minimum 4 Feet Wide Perimeter Width Two rows in Center of Sheet and one raw in Lap
B. FASTENER SPACING FOR CORNER AREA
FS= 3.643024 inches
USE MAXIMUM 4 INCHES SPACING (Min. of 4" Based on Section 8.1 of RAS 117 of 2010 FBC)
Minimum 4 Feet by 4 Feet Area for Comer - Three rows in Center of Sheet and one row in Lap
C. FASTENER SPACING FOR FIELD AREA
FS = 9.192612
USE MAXIMUM 9"LAP AND 9"FIELD SPACING (Based on Product Approval)
Two rows in center of sheet 9" o.c. and one row Side Lap Spacing 9" o.c.
MIAMI-DADE COUNTY
MIAMI•DADE PRODUCT CONTROL SECTION
® 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DMSION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.sov/economy
GAF
1361 Alps Road
Wayne, NJ 07470
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Conventional Built -Up Roof System for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA No. 07-1219.09 consists of pages 1 through 17.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 1 of 17
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub -Category:
BUR
Material:
Fiberglass
Deck Type:
Wood
Maximum Design Pressure:
-75 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
GAFGLAS®#75 Base
39.37" (1 meter)
ASTM D 4601
Type II asphalt impregnated and coated glass mat
Sheet
Wide
base sheet.
GAFGLAS® #80 Ultima7m
39.37' (1 meter)
ASTM D 4601
Type II asphalt impregnated and coated, fiberglass
Base Sheet
Wide
base sheet.
GAFGLAS® FlexPly'"' 6
39.37' (1 meter)
ASTM D 2178
Type VI asphalt impregnated glass felt with asphalt
Wide
coating.
GAFGLAS® Ply 4
39.37' (1 meter)
ASTM D 2178
Type IV asphalt impregnated glass felt with asphalt
Wide
coating.
GAFGLAS® Mineral
39.37' (1 meter)
ASTM D 3909
Asphalt coated, glass fiber mat cap sheet surfaced
Surfaced Cap Sheet
Wide
with mineral granules.
GAFGLAS® EnergyCap."
39.37' (1 meter)
ASTM D3909
Asphalt coated, glass fiber mat cap sheet surfaced
BUR Mineral Surface
wide
with mineral granules with factory applied
Cap Sheet
EnergyCote''
GAFGLAS® Stratavent®
39.37' (1 meter)
ASTM D 4897
Fiberglass base sheet coated on both sides with
Eliminator"" Perforated
Wide
asphalt. Surfaced on the bottom side with mineral
Venting Base Sheet
granules embedded in asphaltic coating with factory
perforations.
GAFGLAS® Stratavent®
39.37' (1 meter)
ASTM D 4897
A nailable, fiberglass base sheet impregnated and
Eliminator T.Nailable
Wide
coated on both sides with asphalt. Surfaced on the
Venting Base Sheet
bottom side with mineral granules embedded in
asphaltic coating.
Ruberoid® SBS Heat-
39.37' (1 meter)
ASTM D 6164
Non -Woven Polyester mat coated with polymer-
Weld7 Smooth
Wide
modified asphalt and smooth surfaced.
Ruberoid® SBS Heat-
39.37' (1 meter)
ASTM D 6164
Non -Woven Polyester mat coated with polymer-
Weld7 25
Wide
modified asphalt and smooth surfaced.
Ruberoid® 20
39.37' (1 meter)
ASTM D 6163
SBS modified asphalt base sheet reinforce with a
Wide
glass fiber mat.
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 2 of 17
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
Ruberoie Mop Smooth
39.37" (1 meter)
ASTM D 6164
Non -woven polyester mat coated with polymer -
wide
modified asphalt and smooth surfaced.
FireOuim Fire Barrier
5, 55 gallons
Proprietary
Low VOC, water based fire barrier coating.
Coating
VersaShieieFire
350 sq ft. roll
ASTM D 226
Non -Asphaltic Fiberglass -Based Underlayment.
Resistant Roof Deck
Protection
Topcoat® Surface Seal
5 gallons
ASTM D 6083
Solvent based sprayable thermoplastic rubber
SB
sealant designed to protect and restore aged roof
surfaces and to increase a roof s reflectivity.
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description
EnergyGuarC Polyiso Insulation Polyisocyanurate foam insulation
EnergyGuard7 RA Polyiso Insulation Polyisocyanurate foam insulation
EnergyGuardTm RN Polyiso Insulation Polyisocyanurate foam insulation
EnergyGuarC Perlite Roof Insulation Perlite insulation board.
EnergyGuardTM Perlite Recover Board Perlite recover board
EnergyGuarC RA Composite Polyiso Polyisocyanurate foam insulation with high
Insulation density fiberboard or Permalite perlite
insulation
SecurocV Gypsum -Fiber Roof Board Gypsum roof board
StructodeO High Density Fiber Board High density fiber board
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
USG Corporation
Blue Ridge FiberBoard, Inc.
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 3 of 17
APPROVED FASTENERS:
Manufacturer
(With Current NOM
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 4 of 17
TABLE 3
Fastener
Product
Product
Number
Name
Description
Dimensions
1.
Drill -Tec"'
# 12 Fastener
Insulation fastener for steel,
various
wood & concrete decks.
2.
Drill-Tec"m
#14 Fastener
Insulation fastener for steel,
various
wood & concrete decks.
3.
Drill -Tec"'
XHD Fastener
Carbon steel extra heavy duty
Various
fastener used in steel decks.
4.
Drill -Tec"'
ASAP 3S
Drill-TecTm #12 Fastener
Various
with Drill-Tecrm 3" Standard
Steel Plate
5.
Drill-Tec"m
3" Steel Plate
Round galvalume stress plate
3" round
used with Drill -Tec'
fasteners.
6.
Drill -Tec -
3" Standard Steel
Round galvalume plated steel
3" round
Plate
stress plate with reinforced
ribs for use with Drill -Tec"'
fasteners.
7.
Drill -Tec"'
AccuTrac®Flat
AZ -SS aluminized steel plate
3" square
Plate
for use with Drill-Tec'74# 12
Fastener, Drill -Tec"' # 14
Fastener and Drill-Tec'*m #15
Fastener.
8.
Drill -Tec"'
AccuTrace
Galvalume Steel plate for use
3" square
Recessed Plate
with Drill -Tec" fasteners.
Manufacturer
(With Current NOM
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 4 of 17
EVIDENCE SUBMITTED:
Test Amency
Factory Mutual Research Corp
PRI Asphalt Technologies, Inc.
IRT of S. Fl.
Trinity I ERD
Test Identifier
Description
Date
J.1.2B8A4.AM
4470
07/02/97
J.1. 3B9QI.AM
4470
01/08/98
J.I.ODOA8.AM
4470
07/09/99
J.I.ODIA8.AM
4470 - TAS 114
07/29/94
J.I.OY9Q5.AM
4470 - TAS 114
04/01/98
3029832
4470 - TAS 114
05/11/07
GAF -084-02-01
ASTM D 6083
05/09/06
GAF -314-02-01
ASTM D 2178
08/23/11
GAF -315-02-01
ASTM D 2178
08/23/11
GAF -276-02-01 Rev
ASTM D 6083
12/16/10
GAF -276-02-02
ASTM D 226
11115110
GAF -270-02-02
ASTM D226
11/15/10
02-005
TAS 114
01/18/02
02-014
TAS 114
03/22/02
G6850.08.07-1
ASTM D 3909
08/13/07
G34140.04.114
ASTM D 6401
04/25/11
G30250.02.10 -3-R1
ASTM D 3909
11/26/12
G34140.04.11-5
ASTM D 4897
04/25/11
G34140.04.11 -5-R]
ASTM D 4897
10/18/13
G34140.04.11-2
ASTM D 6163
04/25/11
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 5 of 17
Deck Type 1: Wood, Non -insulated
Deck Description: 19/3211 or greater plywood or wood plank decks
System Type E: Base sheet mechanically fastened.
All General and System Limitations shall apply.
Fire Barrier: FireOutTM Fire Barrier Coating, VersaShiele Fire Resistant Roof Deck Protection or
(optional) SecurockTM Gypsum Fiber Roof Board.
Base sheet: GAFGLAS® #80 UltimaTM Base Sheet, Stratavene EliminatorTM Nailable Venting Base
Sheet, Ruberoid® 20, Ruberoid® SBS Heat-WeldTM Smooth or Ruberoid® SBS Heat-
WeldTM 25 base sheet mechanically fastened to deck as described below;
Fastening Options: GAFGLAS® Ply 4, GAFGLAS® F1exPlyTM 6, GAFGLAS® #75 Base Sheet or any of above
base sheets attached to deck with approved annular ring shank nails and tin caps at a
fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field.
(Maximum Design Pressure —45 psf, See General Limitation #7)
GAFGLAS® Ply 4, GAFGLAS® FlexPlyTM 6, GAFGLAS® #75 Base Sheet or any of above
base sheets attached to deck with Drill-TecTM # 12 Fastener or Drill-TecTM # 14 and Drill-
TecTM 3" Steel Plate, Drill-TecTM AccuTrace Flat Plate or Drill-TecTM AccuTrace
Recessed Plate 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are
equally spaced approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf, See General Limitation #7)
GAFGLAS® Flex PlyTM 6, GAFGLAS® #75 Base Sheet or any of above base sheets
attached to deck with approved annular ring shank nails and tin caps at a fastener spacing
of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field.
(Maximum Design Pressure —52.5 psf, See General Limitation #7)
GAFGLAS® #80 Ultimarm Base Sheet, Ruberoid® 20, Ruberoid® Mop Smooth, base sheet
attached to deck with approved 1'/4" annular ring shank nails and inverted 3" steel plate at a
fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of
9" o.c. in the center of the membrane.
(Maximum Design Pressure —60 psf, See General Limitation #7)
GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM
#12 Fastener or Drill-TecTM #14 Fastener and Drill-TecTM 3" Steel Plate, Drill-TecTM
AccuTraco Flat Plate or Drill-TecTM AccuTraco Recessed Plate 12" o.c. in 4 rows. One
row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the
field of the sheet.
(Maximum Design Pressure —60 psf, See General Limitation #7)
Any of above Base sheets attached to deck approved annular ring shank nails and 3"
inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered
in two rows 9" in the field.
(Maximum Design Pressure —60 psf, See General Limitation #7)
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 15 of 17
GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill-TecTM
# 12 Fastener or Drill-TecTM # 14 Fastener and Drill-TecTM 3" Steel Plate, Drill-TecTM
AccuTraco Flat Plate or Drill-TecTM AccuTrace Recessed Plate 8" o.c. in 4 rows. One row
is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of
the sheet.
(Maximum Design Pressure —75 psf, See General Limitation #7)
Ply Sheet: One or more plies of GAFGLAS® Ply 4 or GAFGLAS® #80 Ultima Base Sheet adhered in a
full mopping of approved asphalt applied within the EVT range and at a rate of 2040
lbs./sq.
Cap Sheet: (Optional) One ply of GAFGLASO Mineral Surfaced Cap Sheet or GAFGLASO
EnergyCapTM BUR Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen
components must be applied according to manufacturer's application instructions
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood
coat of approved asphalt at 60 lbs./sq.
2. Topcoat® Surface Seal SB applied at Ito 1.5 gal./sq.
Maximum Design
Pressure: See Fastening Above
NOA No.: 13-0424.09
MAMI-DADE COUNTY= Expiration Date: 11/04/14
�Wg...e
Approval Date: 10/31/13
Page 16 of 17
WOOD DECK SYSTEM LIX[TATIONS:
I A slip sheet is required with GAFGLAS® Ply 4 and GAFGLAS® Flex PlyTM 6 when used as a mechanically fastened
base or anchor sheet.
2. Minimum '/a" Dens DeckTM Roof Board or %Z" Type X gypsum board is acceptable to be installed directly over the
wood deck.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4'x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be
limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
2751bf, insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered
Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value
taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application
Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within
this NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter hailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE
NOA No.: 13-0424.09
Expiration Date: 11/04/14
Approval Date: 10/31/13
Page 17 of 17
V
TGFU.R14153 - Roofing Systems
TGFU.R141S3
Roofing Systems
Paae Bottom
Roofing Systems
See General Information for Roofina Systems
GAF
R14153
Page 1 of 5
1361 Alps Rd
Wayne, NJ 07470-3700 USA
"Ruberoid@ 20" or "Ruberoid@ 20 HT" or "Ruberoid@ Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the
following Classifications.
1/2 -in. thick (minimum) gypsum board or 1/4 -in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@
Roofboard" or "DensDeck DuraGuardi" Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the
resulting roofing system is acceptable for use over combustible (15/32 -in, thick minimum) roof decks. However, the butt joints in the gypsum
board and Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard" Roofboard" are to
offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment
board.
Multiple piles of "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or'Tri-Ply@ Ply 6" may be adhered to Georgia-Pacific Gypsum LLC "DensDeck @
Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard"" Roofboard" in hot roofing asphalt.
"EnergyGuard'" Ultra" is an acceptable alternate to "EnergyGuardym RF" in any applicable Classification.
"GAF Stratavent@ Eliminator— Venting Base Sheet (Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a
recover over existing roof systems.
"GAFGLAS@ Perlite Insulation" may be utilized as a cover board over "EnergyGuard"" RF" insulation in any of the following systems.
Unless otherwise Indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified urethane insulation
adhesive. Polystyrene referenced in any of the following Classifications Include "EnergyGuard" EPS Insulation".
Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation
Instructions (excluding LRF Adhesive 0) in any applicable Non -Combustible Roof Deck Classifications.
References to glass fiber insulation include "EnergyGuard Fiberglass Insulation".
"EnergyGuard'"' Tapered" is an acceptable alternate to "EnergyGuard""" in any applicable Classification.
ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT
Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or'Tri-Ply@ #75 Base Sheet", or "GAFGLAS@ #80 ULTIMA") is a suitable
alternate for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4", or "GAFGLAS@ Ply 6") in the Class A, B or C roof
systems Indicated below.
The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent@ EllminatorTM Venting Base
Sheet (Perforated)" or "GAF Stratavent@ EliminatorTM Venting Base Sheet (Nailable)." Perforated base sheets to be loose laid or fully adhered
with hot roofing asphalt and nailable base sheets are to be mechanically attached granule side down.
As an option Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or'Tri-Ply@ #75 Base Sheet" or "GAFGLAS@ #80 ULTIMA" or
"GAF Stratavent@ Ellminator' Venting Base Sheet (Nailable)" may be substituted for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or
"Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6") as the nailed base ply in the following systems.
Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened.
Unless otherwise Indicated, all insulations may be hot mopped or mechanically fastened.
"GAFGLAS@ Flashing" or "Ruberoid@" may be used for Flashing in any of the Class A, B or C systems listed below.
When "perlite" is referenced, this includes "GAFTEMP PERMALITE@" or any other UL Classified perlite insulation.
Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed.
Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C-15/32
or NC.
The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1/2-1n. minimum thick
gypsum board Is an acceptable alternate for minimum insulation over C-15/32 thick roof decks.
The use of polystyrene insulation board between minimum 3/4 -in. thick perlite board and deck with rosin paper (perlite/rosin
paper/polystyrene/perlite) is a suitable alternate for polylsocyanu rate board in the following Class A, B or C systems.
"EnergyGuard" RA" or "Tapered EnergyGuardTM RA" or "EnergyGuard"' Composite RA" may be substituted for any Atlas Roofing Corp.
polyisocyanurate Insulation in any of the following Classifications.
Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt".
"GAFGLAS@ #80 Premium Base Sheet" may be used in any of the following systems.
http://database.ul.com/cgi-binIXYVItemplate/LISEXT/1 FRAMElshowpage.html?name=T... 10/7/2014
TGFU.R14153 - Roofing Systems Page 2 of 5
' "GAFGLAS@ Flex Ply 6" and "Tri -Ply® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLAS@ Ply 6".
"GAFTEMP Permalite Recover Board" may be used In lieu of any perlite insulation in any of the following NC Classifications.
Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "TOPCOAT@ Fireshield MB" at 21/2 to
3-gal/100-191:2.
"Ruberoid@ Dual Smooth" may be used as an alternate to "Ruberoid@ Mop Smooth" or "Ruberoid@ 20" or "Ruberoid@ 20 HT".
"Ruberoid@ Mop Smooth 1.5" may be used as an alternate to "Ruberoid@ Mop Smooth".
Class A. B and C
Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes.
"Ruberoid@ Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid@ Mop" SBS products In any applicable Classification.
Class A
1. Deck: C-15/32
Incline: 3
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Three or more plies Type G1 or "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Ply 6" hot mopped.
Surfacing: — Gravel.
2. Deck: C-15/32
Incline: 2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polylsocyanu rate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Three or more plies Type GS or "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or 'Tri -Ply@ Mineral Surfaced Cap Sheet " or "GAFGLAS@
EnergyCap— BUR Mineral Surfaced Cap Sheet".
3. Deck: NC
Incline: 2
Insulation (Optional): — One or more layers perlite, wood fiber, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate
composite, perlite/urethane composite, wood fiber/polyisocyan u rate composite, phenolic, 2 -in. maximum.
Ply Sheet: — Two or more piles Type G1 "GAFGLAS@ Ply 4", "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@
EnergyCap° BUR Mineral Surfaced Cap Sheet.
4. Deck: C-15/32
Incline: 1
Slip Sheet (Optional): — Red rosin paper, nailed to deck.
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with
OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive.
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" (may be nailed).
Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or GAFGLAS@ Ply 6".
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@
EnergyCapTM BUR Mineral Surfaced Cap Sheet".
Surfacing (Optional): —'TOPCOAT@ EnergyCote— Elastomeric Coating" applied at a rate of 2-gal/100-ft2.
5. Deck: NC
Incline: 3
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet".
Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or'Tri-Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@
EnergyCapl BUR Mineral Surfaced Cap Sheet."
6. Deck: C-15/32
Incline: 2
Insulation: — One or more layers perlite, glass fiber, polyisocyanurate, urethane, perlite/polyisocyanurate composite, perlite/urethane
composite, phenolic, 1 in. minimum (offset a minimum of 6 -in. from plywood deck joints).
Base Sheet: — One or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid@ Torch Smooth" or "Ruberoid@ Torch Granule" or "Ruberoid@ Torch Granule Plus" or
"Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberold@ Mop Smooth Plus" or "Ruberoid@ Mop Granule" or "Ruberoid@
Mop Plus Granule" or "ROOFMatchTM SBS Modified Granular" or "Tri -Ply@ SBS Modified Bitumen Membrane" or "ROOFMatchT APP
Modified Granular" or "Tri -Ply@ TP -4G" or 'Tri -Ply@ TP -4" or "Ruberoid@ Dual Smooth".
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or'Tri-Ply@ Mineral Surfaced Cap Sheet"or "GAFGLAS@ EnergyCap-
BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
7. Deck: C-15/32
Incline: 2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polylsocyanurate composite or phenolic, any thickness.
Base Sheet: — Two or more plies Type G2 or Type G3.
Ply Sheet (Optional): — One or more plies Type G1.
Membrane: — One or more plies "Ruberoid@ Torch Smooth" or "Ruberoid@ Torch Granule" or "Ruberoid@ Torch Granule Plus" or
"Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid@ Mop Granule" or "Ruberoid@
Mop Plus Granule" or "ROOFMatchTM SBS Modified Granular" or "Tri -Ply@ SBS Modified Bitumen Membrane" or "ROOFMatch- APP
Modified Granular" or'Tri-Ply@ TP -4G" or "Tri -Ply@ TP -4" or "Ruberoid@ Dual Smooth".
http://database.ul.com/cgi-binIXYVItemplateALISEXT/1 FRAMElshowpage.html?name=T... 10/7/2014
TGFU.R14153 - Roofing Systems
Page 3 of 5
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or'Tri-Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap'
BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
B. Deck: NC
Incline: 2
Insulation (Optional): — Perlite or glass fiber or polylsocyanurate or wood fiber or mechanically fastened,
Base Sheet: — One or more plies Type G2, "GAFGLAS@ #75 Base Sheet" or "I'd -Ply® #75 Base Sheet".
Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or 'Tri -Ply@ Mineral Surfaced Cap Sheet"
BUR Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
Surfacing: — 'TOPCOAT@ Fireshield MB" applied at 21/2 to 3.0-gal./100-ft2.
9. Deck: C-15/32
Incline. 1
any thickness.
or GAFGLAS@ EnergyCap-
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Three or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — "GASFGLAS@ EnergyCap— BUR Mineral Surfaced Cap Sheet".
10. Deck: NC
Incline: 1
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, 2 -in. maximum.
Ply Sheet: — Two or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — "GASFGLAS@ EnergyCap' BUR Mineral Surfaced Cap Sheet".
11. Deck: NC
Incline: 2
Base Sheet: — One ply Type G2 "GAFGLASe #75 Base Sheet" or'Tri-Ply@ #75 Base Sheet".
Ply Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — "GASFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet".
12. Deck: C-15/32
Incline: 1
Insulation: — One or more layers perlite or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or
perlite/urethane composite or phenolic, 1 -in. minimum (insulation joints offset a minimum of 6 -In. from plywood deck joints).
Base Sheet: — One or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6' or Type G2 'GAFGLAS@ #75
Base Sheet" or "Tri -Ply@ #75 Base Sheet" or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap
Sheet".
Membrane: — One or more plies "Ruberoid@ Torch Smooth" or "Ruberoid@ Torch Granule" or "Ruberoid@ Torch Granule Plus" or
"Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberold@ Mop Granule" or "Ruberoid@
Mop Plus Granule" or "ROOFMatch' SBS Modified Granular" or 'Tri -Ply SBS Modified Bitumen Membrane" or "ROOFMatch' APP Modified
Granular" or "Tri -Ply@ TP -4G" or "Tri -Ply@ TP -4" or "Ruberoide Dual Smooth".
Cap Sheet: — "GASFGLASe EnergyCap"" BUR Mineral Surfaced Cap Sheet".
13. Deck. C-15/32
Incline: 1
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polylsocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Base Sheet: — Two or more plies Type G2 "GAFGLAS@ #75 Base Sheet", "Tri -Ply@ #75 Base Sheet", or Type G3 "GAFGLAS@ Mineral
Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet".
Ply Sheet (Optional): — One or more plies Type G1.
Membrane: — One or more plies "Ruberoid@ Torch Smooth" or "Ruberoid@ Torch Granule" or "Ruberoid@ Torch Granule Plus or
"Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid@ Mop Granule" or "Ruberoid@
Mop Plus Granule" or "ROOFMatchTM SBS Modified Granular" or 'Tri -Ply@ SBS Modified Bitumen Membrane" or "ROOFMatch— APP
Modified Granular" or "Tri -Ply@ TP -4G" or "Tri -Ply@ TP -4" or "Ruberoid@ Dual Smooth".
Cap Sheet: — "GASFGLAS@ EnergyCapT" BUR Mineral Surfaced Cap Sheet".
14. Deck: C-15/32
Incline: 2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate perlite/polyisocyanurate composite
or wood fiber/polyisocyanurate composite any thickness mechanically or adhered with hot roofing asphalt.
Base Sheet. — One ply "GAFGLAS@ Stratavent Eliminator Venting Base Sheet" or Type G2 fully adhered with hot roofing asphalt.
Ply Sheet: — Two or more plies Type G1 or "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus"
or "Ruberold@ 20" or "Ruberoid@ 20 HT' fully adhered with hot roofing asphalt.
Membrane: — "GAFGLASe Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet" fully adhered
with hot roofing asphalt.
15. Deck: C-15/32
Incline: 1
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with
OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive.
Barrier Board: — Minimum'/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or
"DensDeck DuraGuard' Roofboard" or minimum 1/4 -in. thick Untied States Gypsum Corp. "SECUROCK@ Roof Board" (Type FRX-G) or
"SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any
UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -In. from plywood deck joints.
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply #75 Base Sheet" mechanically fastened.
Ply Sheet: — One or two plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply 4" or "GAFGLAS@ Flex Ply 6" or Type G2 "GAFGLAS@ #75 Base
Sheet" or "Tri -Ply #75 Base Sheet" fully adhered with hot roofing asphalt.
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
Surfacing (Optional): — 'TOPCOAT@ EnergyCote'" Elastomeric Coating" applied at a rate of 2-gal/100-ft2.
http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=T... 10/7/2014
TGFU.R14153 - Roofmg Systems
16. Deck: NC Incline: 1/2
Page 4 of 5
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyan u rate, mechanically fastened or adhered with
"LRF Adhesive M" or OMG Inc. "Olybond Fastening System" applied as a nominal 3/4 -in. bead or "GAF 2 -Part Roofing Adhesive" applied as
a nominal 2 -1/2 -in. bead with a maximum on -center spacing of 12 -in. or any UL Classified insulation adhesive applied per the
manufacturer's installation instructions.
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or 'Tri -Ply® #75 Base Sheet", mechanically fastened.
Ply Sheet: — One or two plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ 4" or "GAFGLAS@ Flex -Ply— 6" or Type G2 "GAFGLAS@ #75
Base Sheet" or'Tri-Ply@ #75 Base Sheet", fully adhered with hot roofing asphalt.
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
Surfacing: — "TOPCOAT@ EnergyCote— Elastomeric Coating" or "TOPCOAT@ MB Plus" or'TOPCOAT@ 322 White Elastomeric Coating",
applied at a rate of 2-gal/100-ft2.
17. Deck: C-15/32
Incline: 1/2
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate mechanically fastened or adhered with
OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive.
Barrier Board: — Minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or
"DensDeck DuraGuardTm Roofboard" or minimum 1/4 -in. thick Untied States Gypsum Corp. "SECUROCK@ Roof Board" (Type FRX-G) or
"SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any
UL Classified insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -in. from plywood deck joints.
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply #75 Base Sheet" mechanically fastened.
Ply Sheet: — One or two plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply 4" or "GAFGLAS@ Flex Ply 6" or Type G2 "GAFGLAS@ #75 Base
Sheet" or "Tri -Ply #75 Base Sheet" fully adhered with hot roofing asphalt.
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
Surfacing: — "TOPCOAT@ EnergyCoteTM Elastomeric Coating" or'TOPCOAT@ MB Plus" or "TOPCOAT@ 322 White Elastomeric Coating"
applied at a rate of 2-gal/100-ft2.
18. Deck: NC
Incline: 1
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened or adhered with
"LRF Adhesive M" or OMG Inc. "Olybond Fastening System" applied as a nominal 3/4 -in. bead or "GAF 2 -Part Roofing Adhesive" applied as
a nominal 2 -1/2 -in. bead with a maximum on -center spacing of 12 -in. or any UL Classified insulation adhesive applied per the
manufacturer's installation Instructions.
Base Sheet, — One ply "GAFGLAS@ Stratavent@ Eliminator"' Venting Base Sheet" or Type G2, fully adhered with hot roofing asphalt.
Ply Sheet: — One or two plies "Ruberold@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or
"Ruberoid@ 20" or "Ruberoid@ 20 HT, fully adhered with hot roofing asphalt.
Membrane: — One ply "GAFGLAS@ Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
Surfacing: — "TOPCOAT@ EnergyCoteif° Elastomeric Coating" or'TOPCOAT@ MB Plus" or'TOPCOAT@ 322 White Elastomeric Coating"
applied at a rate of 2-gal/100-ft2.
19. Deck: C-15/32
Incline: 1
Insulation (Optional): — Any thickness perlite or wood fiber or glass fiber or polyisocyan u rate mechanically fastened or adhered with
OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive.
Barrier Board: — Minimum 1/4 -in. thick Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Prime@ Roofboard" or
"DensDeck DuraGuard""' Roofboard" or minimum 1/4 -in. thick Untied States Gypsum Corp. "SECUROCK@ Roof Board" (Type FRX-G) or
"SECUROCK@ Glass -Mat Roof Board" (Type SGMRX) mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any
UL Classified Insulation adhesive with butt joints in the barrier board products staggered a minimum of 6 -In. from plywood deck joints.
Base Sheet: — One ply "GAFGLAS@ Stratavent Eliminator Venting Base Sheet" fully adhered with hot roofing asphalt.
Ply Sheet: — One or two plies "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth Plus" fully adhered with hot roofing asphalt.
Membrane: — One ply "GAFGLAS@ Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
Surfacing: —'TOPCOAT@ EnergyCoteT Elastomeric Coating" or'TOPCOAT@ MB Plus" or'TOPCOAT@ 322 White Elastomeric Coating"
applied at a rate of 2-gal/100-ft2.
20. Deck: C-15/32
Incline: 1
Base Sheet: — One ply Type G2 "GAFGLAS@ #75 Base Sheet" or'Tri-Ply@ #75 Base Sheet" mechanically fastened.
Insulation (Optional): — Any thickness or combination: perlite or wood fiber or glass fiber or polyisocyanurate, mechanically fastened
or hot mopped or adhered with OMG Inc. "OlyBond Fastening System" or any UL Classified insulation adhesive.
Base Sheet: — One or more plies "Ruberoid@ 20" or "Ruberoid@ 20 HT' or "Ruberoid@ Modified Base Sheet", hot mopped or
mechanically attached.
Cap Sheet: — One ply Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or'Tri-Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@
EnergyCap'" BUR Mineral Surfaced Cap Sheet".
1. Deck: C-15/32
Class B
Incline: 3-1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Two or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6" mechanically fastened.
Cap Sheet: — Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCapT"
BUR Mineral Surfaced Cap Sheet", fully adhered with hot roofing asphalt.
2. Deck: C-15/32
Incline: 3-1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Base Sheet: — Two or more plies Type G1 or Type G2 or Type G3.
Membrane: — One or more plies "Ruberoid@ Torch Smooth" or "Ruberoid@ Torch Granule" or "Ruberoid@ Torch Granule Plus" or
"Ruberold@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberoid@ Mop Granule" or "Ruberoid@
http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=T... 10/7/2014
TGFU.R14153 - Roofing Systems
Page 5 of 5
Mop Plus Granule" or "ROOFMatch- SBS Modified Granular" or "Tri -Ply® SBS Modified Bitumen Membrane" or "ROOFMatch' APP
Modified Granular" or'Tri-Ply® TP -4G" or'Tri-Ply® TP -4" or "Ruberoid@ Dual Smooth".
Cap Sheet: — "GAFGLAS@ Mineral Surfaced Cap Sheet", or'Tri-Ply® Mineral Surfaced Cap Sheet" or "GAFGLAS@ EnergyCap— BUR
Mineral Surfaced Cap Sheet" fully adhered with hot roofing asphalt.
3. Deck: C-15/32 Incline: 2-1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polylsocyanurate or urethane or
perlite/polylsocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Two or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Cap Sheet: — "GAFGLAS@ EnergyCap— BUR Mineral Surfaced Cap Sheet".
4. Deck: C-15/32 Incline: 2-1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Base Sheet: — Two or more plies Type G1 "GAFGLAS@ Ply 4" or 'Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6" or Type G2 "GAFGLAS@ #75
Base Sheet" or "Tri -Ply@ #75 Base Sheet' or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap
Sheet".
Membrane: — One or more plies "Ruberoid@ Torch Smooth" or "Ruberoid@ Torch Granule" or "Ruberoid@ Torch Granule Plus" or
"Ruberold@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberold@ Mop Granule" or "Ruberoid@
Mop Plus Granule" or "ROOFfMatchTM SBS Modified Granular" or'Tri-Ply@ SBS Modified Bitumen Membrane" or "ROOFMatchTM APP
Modified Granular" or'Tri-Ply@ TP -4G" or "Tri -Ply@ TP -4" or "Ruberoid@ Dual Smooth".
Cap Sheet: — "GAFGLAS@ EnergyCapTM BUR Mineral Surfaced Cap Sheet".
Class C
1. Deck: C-15/32 Incline: 1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Three or more plies Type G1 "GAFGLAS@ Ply 4" or'Tri-Ply@ Ply 4" or "GAFGLAS@ Ply 6".
Surfacing: — "Special Roofing Bitumen" applied at 20-lbs/100-ft2.
COAL TAR FELT SYSTEMS WITH HOT ROOFING COAL TAR
Class A
1. Deck: C-15/32 Incline: 1/2
Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or
perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness.
Ply Sheet: — Three or more plies Type G1 "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6" hot mopped with coal tar
bitumen.
Surfacing: — Gravel.
h4://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=T... 10/7/2014
• Owner's Notification Form HVHZ 2010
H�
e1're•n•F'tn. kea.rt'la•Qzt'-k'vc•l;t tl�y" SECTION 1524
1UGH VLLO.CM HURIUCME ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1 Scope. As it pertains to this section, it is the responsibility of the rooring contractor to provide the yawner
with the required roofing permit, and to explain to the owner the content of this section. The provisions of
Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the
industry for roofing system installations. Additionally, the following items should be addressed as part of the
kZoneeement between the owner and the contractor. The owner's initial in the designated space indicates that the
as been explained.
1. Aesthetics-�workmanshlip: The workmanship provisions of Chapter 15 (High Velocity Hurricane
are for the purpose of providing that the roofing. system meets the wind resistance and water intrusion
performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions.
Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed
art. of the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renar ed in accordance with the current provisions of Chapter 16 (High Velocity Hurricane Zones) of the Florida
jkpilding Code. (The roof deck is usually concealed prior to removing the existing roof system).
3. Common roofs: Common roofs are those which have no visible delineation between neighboring
units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the roofing contractor and/or
er should notify the occupants of adjacent units of roofing work to be performed.
4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be
viewed from 'belo . The `owner: may wish tci-maintain the architectural appearance; therefore, roofing nail
penetrations of the underside of the decking; may not be acceptable. The owner provides the option of
%aintaining this appearance.
3 Ponding water: The current roof system and/or deck of the building may not drain well and may
cause water to pond (accumulate) in low-lying areas of the roof Ponding can be an indication of structural
distress and may require the review of a professional structural engineer. Ponding may shorten the life
expectancy and,performance of the, neve roofing system. Ponding conditions may not be evident until the original
offing system is removed. Ponding conditions should be corrected.
4L] 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if
overflow scuppers wall outlets are not provided. It may be necessary to install overflow scu a 0•• accor
Ap ( ) P Y rY . pp � �. dpAq.e..
th the -requirements of; Chapter 15 and 16 herein and the Florida Building Code, PfuObbig. .. • •
•0000. 0000 0000..
7. Ventilation: -Most roof structures should have some ability to vent natural".. through the •
interior of the struc al assembly (the buil g itself). The existing amount o� attic velrtikattpn shall toot be
reduced. Exception: c spaces, designe a Florida -licensed engineer or, registeretr chitect Jg ��iminate.:. •
0000..
the attic venting, venting A of be uir •
99 •• •..• •9999•
•
Owner's/Agent's Signature: Nk,�.,.,:,,,�, Date: / •�� �, 1
•
.0090.
Contractoes Signature: Permit Number: ' .' •
Property Address: e t 11 i►
NOTICE OF COMMENCEMENT
A RECORDED COPY MUST BE POSTED ON THE JOB SITE AT TIME OF FIRST INSPECTION
PERMIT NO. TAX FOLIO NO.-! I®IV Q ®1® 'd/
STATE OF FLORIDA:
OR Bk 29329 Psi 4563v
RECORDED 09130/201,1• 1 9549=
Iry:tl4'INP CLERK OF COURT
MIAMI --DARE COUNTY? r FLORIDA
1. AST PAGE
COUNTY OF MIAMI-DADE: d TATE OF FLORIDA, COUNT OF DADE
HERE® Y CERTIFY that this 1s a true copy of the
THE UNDERSIGNED hereby gives notice that improvements will be,rpVpfi;pd$A A0on day of
property, and in accordance with Chapter 713, Florida Statutes, the follo fent '4 , AD 20
is provided In this Notice of Commencement. .vITNESS my hand and Official seal.
1 RVEY RUVIN C EE V, et 8W C0Ur tV Cowcs
�gl(_I �I� t o.C.
2. Description of
3. Owner(s) name ancl address:
Interest in property:
Name and address of fee simple titleholder:
4.,Qontractor's name. address and nhons n
5. Surety: Payment bond required by owner
Name, address and phone number:
Amount of bond $
6. Lender's name and address:
Space above reserved for use of recording office
Nts
7. Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)7., Florida Statutes,
Name, address and phone number: &I 5�
8. In addition to himself, Owners designates the
713.13(1)(b), Florida Statutes,
Name, address and phone number:
9. Expiration date of this Notice of Commencement:
person(s) to receive a copy of the Lienor's Notice as provided in Section
(the expiration date is 1 year from the date of recording unless a different date Is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE
FIRST INSPEGTJON. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK
OR RECORD GUR NOTICE OF COMMENCEMENT.
Signatur of Owne ) orwn 'Authorized Officer/Director/Partner/Manager
Prepared By Prepared By _ •
Print Name Print Name . •
Title/Office Title/Office : . • •
STATE OF FLORIDA '� . • • •
COUNTY OF - k ?- •••v•• •••• ••••••
The for going i tr ent s acknowledged before me this day of •••• •�� ••••';
By • • • • •
❑ Individually, or ❑ at
for' •'
❑Personally known, or roduced the fallowing type of identific on: • • ' ••
Signature of Notary Public: a '� '
Print Name:
(SEAL)
the
of
By —�
12301-52 PAGE 5/12
of kerjury, I deNathat I have read the foregoing
ated i it are tru t the best of my knowledge and
> s)
ft
thorized Officer/Director/P
By
STEPHAMS NATAL 40%111A
• • • •
• •
•
W ( MMISSION # EESS0981
• • • •
EXPIRED march OCs, 2017