RF-14-1646Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-222240 Scheduled Inspection Date: October 29, 2014 Inspector: Rodriguez, Jorge Owner: HUMBLES, ALISON Job Address: 300 NW 112 Terrace Miami Shores, FL 33168-3300 Project: <NONE> Permit Number: RF -7-14-1646 Permit Type: Roof Inspection Type: Final Roof Work Classification: Tile Phone Number (617)872-6367 Parcel Number 1121360010260 Contractor: ISAACS ROOFING & INSULATION CORP Phone: (305)234-5234 rsunaing uepartment comments RE ROOF TILE TO TILE AND FLAT TO FLAT Infractio Passed Comments INSPECTOR COMMENTS False Inspector Comments Passed CREATED AS REINSPECTION FOR INSP-222186. CREATED AS REINSPECTION FOR INSP-216834. Need to cut out excess cap sheet from roofs edge Missing renailing affidavit Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. October 28, 2014 For Inspections please call: (305)762-4949 Page 25 of 46 RE: Permit # Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Falx: (305) 756.8972 DATE: /0 z a a l INSPECTION AFFIDAVIT licensed as a (n) Contractor / Engineer / Architect, (Print name and circle License Type) FS 468 Building Inspector License #: C(-., 13 a. 7*1 On or about 1L? 7 -)2 ojfZ , g 0 /WL , I did personally inspect the roof deck nailing and (Date & time) Secondary water barrier work at (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit Man al (eased on 553.844 F.S) Signature State of Florida County of Dade: The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property menbor.od. Swom to and subscribed before me this Notary Public, Sate of Florida at *General, Building, Residential, or Roofing Contractors or permit # and address # dearly shown marked on the dec Revised on 5/2112009 % ALEJANDRA 8RIT0 -Ngj r Public • State of Florida My Comm. Expires Jun 10. 2018 Commission # FF 101837 individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with each inspection F.I.E. FLORIDA INTERNATIONAL ENGINEERING &TESTING LAB INSIGHT•INNOVATION•INTEGRATION Owner's Narr Job Address: Roofing Cont Permit Numt Florida International Engineering and Testing Lab LLC 16701 SW 117 Avenue, Miami, FL 33177 Telephone: (305) 378 -1991 -Fax: (305) 378-1997 Miami -Dade Lab Certification # 07 -0612.11 -State of Florida ca #27273 Approximate Roof Height: Q ® feet Type of Access to Roof: Ladder Slope: �� Approximate Square Footage: ?.I to 00 ft2 OtherRequired Testin F rce��:����° 35 lbs. Testing Equipment: F.G.E. 10 x S , im o Instrument Date Installed: i ®q 1"R-0 ! Date of Inspection: D --------------------- ----- _ ------------------------- �E' - TEST RESULTS P= PASS, F= FAIL Test Location P or F Test Location P or F Test Location P or F Test Location P or F Test Por F Location 1 Vk421 P,�41 61 81 2 22 42 62 82 3 23 43 63 83 4 24 44 64 1 84 5 25 45 65 85 6 26 46 66 86 7 27 47 67 87 8 28 48 68 88 9 29 49 69 89 10 30 50 1 70 90 11 1 31 51 71 91 12 32 52 72 92 13 33 53 73 93 14 34 54 74 94 15 35 55 75 95 16 36 56 76 1 96 17 1 37 57 77 97 18 38 58 78 98 19 39 59 79 99 20 40 60 80 1 00 ----------------------- --------------------------------------------------------------------------------------------- IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST. ADDITIONAL TEST INFORMATION Perimeter Width: , ft Area Units or ft2 No. of Tests Perimeter ® 0 �C' Field ®® Corners 61 Hips & Ridges �® RESP E�6�kLYt�SWk�,1 ED BY: No 63107 StAe,otQ . 7 vlit', IQ rs gds a -' b%%%" FLORIDA INTERNATIONAL ENGINEERING & TESTING LAB, LLC Miami- Dade Lab Certification # 07-0612.11 Job Address: Contractor: e Other: Sketch of Roof Notes Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JOB ADDRESS: a ®® V11111) k 12 ' r2 JUL 20 2014 BY: FBC 2010 Permit No — 14 "0 Master Permit No. ROOFING City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO i-_" Flood Zone: OWNER: Name (Fee Simple Titleholder):_ LAEhes Phonek Address: tJ "� VkTA°-• City: State: _-F - Zip: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: ►!'- Address: ('� 2:7 City:/� -1 Qualifier Name: 41 4--t,� State Certification or Registration #: C �t 3y� S CO Certificate of Competency #: Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $T'"Z, Square/Linear Footage of Work: Type of Work: ❑Addition ❑Alteration ❑New \ eplace ❑Demolition Description of Work: 74& � 9_cD f t i LC 7, 'CLUE f l'f1 nea -641, Color thru tile: Submittal Fee $ ��� �� Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $92C) . n q o co Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As o condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature -&&,, Ka4!9" OWNER or AGENT The foregoing instrument was acknowledged before a this 2, , day of U- 20 by who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Signature CONTRACTOR The foregoing instrument was acknowledged before me this ZAr, day of 20 . by aW-=� ,-who is personally known to as me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: J"Y 11" Gilda Pereda Seal: �rA...a . a `c+,'_COMMISSICd#EE144691 1$ EXPIRES: DEC. 07, 2015 aw�s�*xsrx��`a+sVA! _ `G�p era+r*_xxa+ea+���sx*****�►��� APPROVED BY Plans Examiner Structural Review (Rev1sed02/24J2014) ELIZABETH J HUBBARD MY COMMISSION b EELS5795 EXPIRES December 03, 2010 Zoning Clerk Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2rw Ave Miami Shores, FI 33138 d Re: Owner's Name: Property Address: C> LL2t P- Roofing Permit Number. Dear Building Official: I Ak-& sLJ certify that I am not required to retrofit the roof to wall connections of my building because: ®'rhe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) hh'. 14"4&j '5V') 'u VAA is L6f Signature State of Florida County of Dade Print Name The undersigned, being the first duly sworn, deposes and says that he/she is the owner for Pe above property mentioned. ��� PG �. Sworn to and subscribed before me this a"' day of �+� a 8�,, Gilda Per144 �:COMMISSICif#EE144691 re, rgorc-1� v ,��,,�.��„� .•op+°;; EXPIRES: DEC. 07, 2015 M'WW.AARONNOTARY.Com Notary Public, Sate of Florida at Large When the p9vah a5m of ere structure for purpose of ad vabr n Wxdw is "to a w than $3o0.=M. and the buift was nW consW0d v0 FIX nor a 1994 SFBC. Then you mst protide a WHing appr+cdm from a General Contr ft for fhe Roof to WPI wmwcft Hurricane ft9don. Revised on 5/21/2409 Section A MI1AMI'DADE Miami -Dade County Building Department Electronic Application ® High Velocity Hurricane Zone Roofing Permit Application Form "Delivering Excellence Every Day" Section A (General Information) Master Permit No: Process No: Contractor's Name: I Isaacs Roofi Job Address: 1 300 NW 112Tr. R1 Low Slope Roof Category ❑ Mechanically Fastened Tile ❑ Mortar/AdhesivejSet Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑ Other: _ Roof Type ❑ New Roof ❑✓ Re -Roofing ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No If yes, what type?; 4• Naturat.O.LPGX ...... .. . . Roof System Information ••• •• ...... • 0*6000 Low slope roof area (ft. 300 Steep Sloped area (ft.2) 2000 Total (ft.2)2300" • • Section B (Roof Plan) • • • • % '..' ..... Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and.oeierli8w drah-C Jgdlude • • • • • ons of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets, • • • • • ier Width (a'): Corner Size (a' x a'): ; 00000 • ••o* •••• FE1 W CD D C in m z ® ® N Z 5 '0 a --i O C o rn ® < Z 9 C � C Fn m z -+ cn 0 CD 0 a s < M o Oa C: m 4 m O Z G f M Tile Roof System O iAMNf Miami -Dade County Building & Neighborhood Compliance Department O HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section D Tile Roof System Roof System Manufacturer: Eagle Notice of Acceptance Number (NOA): 12-0430.04 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P1: 145.1 1 P2: 78.6 P3: 116.2 Maximum Design Wind Pressures, (From the NOA Specific system): 4 psf Fill in the speck roof assembly components. If a component is not required, insert not applicable (n/a) in the text box. Roof Slope: 3 5 _ 11/12" Roof Mean Height: 10 ft. Method of Tile Attachment: --Adhesive, 2 Small Paddy Tile Bond -- Alternate Method of Tile Attachment per NOA: n/a Drip Edge Size & Gauge: 73" face 24 ga: - Drip Edge Material Type: --Galvinized Metal -- Deck Type: 71" x 6" T & G-- Optional Insulation: n/a 0000 0 Optional Nailable Substrat*: "" 000006 6 6 n/a 0000.. - 0000.. � • • 6 g 666666 Optional Nailable SubstratO ct�ment -* • 6 ' ' 06000 n/a 6...66 .. :0000.' . 6. •• 0000 0000.. 666.66 • Basesheet Type: : ' ; • 30# ' .66666 0000 Fastener Type for Basesheet Attachment: 1 1/4" Ring shank nail & Tin caps Tile Underlayment (Cap Sheet) Type: TU Pius Tile Underlayment Attachment Method: Self adhered Drip Edge Fastener Type: 1 1/4" Ring shank nail Tile Profile: Bel Air Flat Hook Strip/Cleat gauge or weight: --n/a Section E MIAMI'N Miami -Dade County Building & Neighborhood Compliance Department ° HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based file systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. P 1: 45.1 X X.278 = 12.54 - Mg: 7.59 ` = Mr1: 4.95 s 131.3 1 NOA Mf P 2: 78.6 X X.278 = 21.85 - Mg: 7.59 - - _ Mr2: 14.26 s 1.31.3 NOA Mf P 3: 116.2 X X.278 = 32 30 - Mg: 7.59 = Mr3: 24.74 s 31.3 NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the P values are greater than or equal to the Fr values, for :ac rea of the roof, then the file attachment method is acceptable. P1: x , = xw: _ - W. = • • •66 • x cos 8: = Fr1: • 6. 5 A •66 • • .. ,._ x I: = x w: _ - W: = x cos 6: = Fr2: << F t�*IN16A ......P2: :.•..: • • P3: X I: = x w: _ - W: = • 0 . • ee x cos 6: = Fr3: • : ; • NQ; • • • • • • • • •• •• 6666 • .: • • 6666•• 6666•• re to Obtain Information to complete tile calculations ; •• • '. 0 .6006. Description Symbol Where to Find " 0 :066 0000 • • Design Pressure P1 or P2 or P3 Table NIRAS 127, or by an engineer analysis prepared, signed and sealed by a professional engineer baspd on ASCE 7. Mean Roof Height H Job Site Roof Slope 8 Job Site Aerodynamic Multiplier Product Approval (NOA) Restoring Moment due to Gravity Mg INRoduct Approval (NOA) Attachment Resistance Mf Produ pproval (NOA) Required Moment Resistance Mr Calcu ed Minimum Attachment Resistance F Product Approval A) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NOA) Tile Dimensions I = length w = width Product Approval (NOA) Section C M1AMk Miami -Dade County Building & Neighborhood Compliance Department g 12! HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section C page (Low Slope Roof Systems) Fill in the speciflc roof assembly components. if a component is not required, insert not applicable (n/a) in the text box. ROOF SYSTEM MANUFACTURER: I Polyglass Product Approval (NOA): 13-0514.10 System Type: I E (1) Wind Uplift Pressures, From RAS 128 or Sealed Calculations: (P1) Field: 142.81psf (P2) Perimeters: 71 •T psf (P3) Comers: 108 psf Maximum Design Pressure From NOA: 52.5 psf Roof Slope: _1/8 " : 12 Roof Mean Height: 20 ..__....... ft. Parapet Walls: O No ❑ Yes Parapet wall Height: 0 Deck Type: —1" x 6" T & G— Support Spacing: Na " o/c Alternate Deck Type: n/a Existing Roof: Na Fire Barrier: Na Vapor Barrer: Na Anchor Sheet: 75# & Elastobase Anchor Sheet Fastener / Bonding Material: 1 1/4" ring shank nails Insulation Base Layer Size & Thickness: Na Insulation Base Layer Fastener/ Bonding Material: F Insulation Top Layer Size & Thickness: Na Insulation Top Layer Fastener / Bonding Material: n/a Base Sheet(s) & No. of Ply(s): 1- Elastoflex SA V FR Base Sheet Fastener / Bonding Material: Self -Adhered Ply Sheet(s) & No. of Ply(s): Na Ply Sheet Fastener/ Bonding Material: n/a Single Ply Manufacturer/ Type: Na Single Ply Sheet Width: " 1/2 Sheet Width: r7" No. of Single Ply 1/2 sheets: Single Ply Membrane Fastening / Bonding Material: Na S FASTENER SPACING FOR BASESHEET ATTACHMENT ❑ SINGLE PLY MEMBRANE ATTACHMENT ••.• 1. Field: 18 1" o/c @Laps & Erows 8 • " o/c ' • • • • 2. Perimeter. 6 " o/c @ Laps & 4 fAwB. 6 " o/c 3. Comer: ILJ" o/c @ Laps & LLJroyp. LU " o% . NUMBER OF FASTENERS PER INSULA X"111OARD:: • • .0000. •• 1. Field: 2. Perimeter: • 8. Comer. •, • • Insulation Fastener TYID 000000 • � • • Na .0600 WOOD NAILER TYPE AND SIZE: • • • sees 0000 Na ..._.-_.__... Wood Nailer Fastener Type and Spacing: Na 0000•• • • • 0000•• 6.6•• 0000• 0000•• • 0000•• EDGE & COPING METAL SIZES: Edge Metal Material: -Galvanized Metal— Edge Size: —3" face 26 ga.- Hook Strip Size: PELECT EDGE METAL HOOK STRIP SIZE— . _ ._.. _..... _..... . Edge Metal Attachment: Na Coping Material: SELECT PARAPET WALL COPING MATERIAL— Coping Size: —SELECT COPING METAL SIZE OR THICKNESS - Hook Strip Size: SELECT COPING METAL HOOK STRIP SIZE— Parapet Coping Metal Attachment: n/a Section C2 Ran Miami-Dade County Building & Neighborhood Compliance Department HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 15 HVHZ, FBC. jPolyf lex SA P file:NCl/Documents%20and%20Settings/sky/Desktop/root%20permit%20forms/Section%20C2d.htm9/5/2007 7:18:20 AM •• • 00• 0 66000• •• 000000 •00••0600• • • • • 600• • •• •066• •0060• • •• • • •606• •6 •• •000 000000 • • pti • Y • + Mean Roof Height • • 0 ••600• • 0 •6000• file:NCl/Documents%20and%20Settings/sky/Desktop/root%20permit%20forms/Section%20C2d.htm9/5/2007 7:18:20 AM Owner's Notification Form HVHZ 2010 rourwyl- "Delivering Excellence Every Day" SECTION 1524 HIGH VELOCITY HURRICANE ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the designated space indicates that the item has been explained. . Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High. Velocity Hurricane Zones) of the Florida Building Code. (The roof deck is usually concealed prior to removing the existing roof system). 3. Common roofs: Common roofs are those which have no visible delineation between Upighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the rootng epntraclor-add/or ... • • • owner should notify the occupants of adjacent units of roofing work to be performed. • • • • • • . . 6 •• 0000.. 0. 4. Exposed ceilings: Exposed, open beam ceilings are where the underside 0oJ0•0tW roof decking cao0� g•, viewed from below. The owner may wish to maintain the architectural appearance; tAerefdre, rcgb$gg•nail 00:000 ' penetrations of the underside of the decking may not be acceptable. The owner provid8.1...'tlf�. optip%of .0006 666. 000000 maintaining this appearance. 0000.. • 5. Ponding water: The current roof system and/or deck of the building may not drain lrall%nd may •' • cause water to pond (accumulate) in low-lying areas of the roof. Ponding can bean &dicalion of slWturaf ••••• : distress and may require the review of a professional structural engineer. Ponding may shorten 14 life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. L�� —6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing. entilation: Most roof structures should have some ability to vent natural airflow through the interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. Owner's/Agent's Signature: Date: Contractor's Signature: Permit Number: 71 Property Address: Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle Low Profile Concrete Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. 4444 TERMINATION of this NOA will occur after the expiration date or if there has been a revtslon ®r change m the 0000.. materials, use, and/or manufacture of the product or process. Misuse of this NOA as an end9 seplept of any Mcrduct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure iG pbuWly with apy sectiop of this NOA shall be cause for termination and removal of NOA.0000 0 0 .0 400• . .0 00000 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flvdda,:and ftllpq by the a we expiration date may be displayed in advertising literature. If any portion of the NOA is disolayhh, then it thhfl be doAA 0 4 in its entirety. :":0: 400 0 4 4 900400 440444 INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturel or itis distrlbiltpi %and :O 0.4 0 shall be available for inspection at the job site at the request of the Building Official. 00:0 This revises NOA# 11-0321.02 and consists of pages 1 through 10. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 1 of 10 S..awv M "M , MIAM MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidaae. ov/oera Eagle Roofing Products LLC 1575 East C.R. 470 Sumterville, FL 33585 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle Low Profile Concrete Tiles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. 4444 TERMINATION of this NOA will occur after the expiration date or if there has been a revtslon ®r change m the 0000.. materials, use, and/or manufacture of the product or process. Misuse of this NOA as an end9 seplept of any Mcrduct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure iG pbuWly with apy sectiop of this NOA shall be cause for termination and removal of NOA.0000 0 0 .0 400• . .0 00000 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flvdda,:and ftllpq by the a we expiration date may be displayed in advertising literature. If any portion of the NOA is disolayhh, then it thhfl be doAA 0 4 in its entirety. :":0: 400 0 4 4 900400 440444 INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturel or itis distrlbiltpi %and :O 0.4 0 shall be available for inspection at the job site at the request of the Building Official. 00:0 This revises NOA# 11-0321.02 and consists of pages 1 through 10. The submitted documentation was reviewed by Alex Tigera. APPROVED NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 1 of 10 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE: This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION: Manufactured by Test Product Applicant Dimensions Specifications Description Bel Air Concrete Tile L = 17" TAS 112 Flat profile concrete roof tile equipped with two W = 12'/4" nail holes. For adhesive set, direct deck or Thickness ='/Z" battened nail -on applications. Bel Air Double Eagle L = 17" TAS 112 Flat profile concrete roof tile equipped with two Concrete Tile W = 12'/4" nail holes. For adhesive set, direct deck or Thickness ='/2" battened nail -on applications. Ponderosa Concrete Tile L = 17" TAS 112 Flat profile concrete roof tile with slate finish W = 12'/4" equipped with two nail holes. For adhesive set, Thickness ='/2" direct deck or battened nail -on applications. Ponderosa Double Eagle L = 17" TAS 112 Flat profile concrete roof tile with shake finish Concrete Tile W = 12'/4" equipped with two nail holes. For adhesive set, Thickness ='/2" direct deck or battened nail -on applications. 9999 Golden Eagle Concrete L = 17" TAS 112 Flat profile concrete rQgf tife brusjfX1744ish **0::* Tile W = 12'/4" equipped with two n§U JVJ�s. For adhave sed••,:9 Thickness ='/Z" direct deck or battened "on applications. . .9000. 9999 .. Trim Pieces 1= varies TAS 112 Accessory trim, clay roof pieces for use at hips • • • w = varies • rakes, ridges and valla . tgiinatigns, • • 0 • • • • • varying thickness Manufactured for eaW till profile. "" ""0 .0000. so . . ..9..9 0000.. . 9 .0000. 90 . 0000 9 NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 2 of 10 2.1 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Revort Date PRI Asphalt Technologies ERPF -001-02-01 TAS 112 Aug. 2006 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) Redland Technologies P0402 Withdrawal Resistance Testing of screw vs. Sept. 1993 smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994 TAS 108 (Nail -On) Redland Technologies P09647-01 Wind Tunnel Testing Aug. 1994 TAS 108 (Mortar Set) The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. TAS 101 (Mortar Set) The Center for Applied 25-7094-(2, 5, & 8) Static Uplift Testing Oct. 1994 Engineering, Inc. TAS 102 The Center for Applied 25-7183-(5 thru 6) Static Uplift Testing Feb. 1995 Engineering, Inc. TAS 102 The Center for Applied 25-7214-(1, 5, & 8) Static Uplift Testing March, 1995 Engineering, Inc. TAS 102 The Center for Applied 25-7487-2 Static Uplift Testing Dec. 1995 Engineering, Inc. TAS 102 The Center for Applied 25-7496-(1 & 4) Static Uplift Testing Dec. 1995 Engineering, Inc. TAS 102 The Center for Applied 25-7804-6 Static Uplift Testing • �� •1996 Engineering, Inc. TAS 102 • • • Celotex Corporation Testing 520109-1 Static Uplift Testing • • • ; • • Dee ! 1998 .... `• Service 520111-4 TAS 101 '•"" ' Celotex Corporation Testing 520191-1 Static Uplift Testing '....' ;Marogh 1999..... Service TAS 101 ...... .. ..:..' Walker Engineering, Inc. Calculations . .. Aerodynamic Multiplier'S.e0 . ...... . 0 2006 • Walker Engineering, Inc. Calculations Restoring Moments Due to Gravity % • Se�p..� 006 • • • • • .60 .. . . 000*0* .... . 0000 NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 3 of 10 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight -W (lbf) Length -i (ft) Width -w (ft) Bel Air, Bel Air Double Eagle, 11.4 1.42 1.03 Ponderosa, Golden Eagle, Ponderosa, Golden Eagle, •..• ... Ponderosa Double Eagle Flat ...... '.: .. Tile Table 2: Aerodynamic Multipliers - A (ft) Tile Profile A (ft) A (fe) Batten Application Direct Deck AppQ2glion Bel Air, Bel Air Double Eagle, 0.301 A.278 •....• .. Ponderosa, Golden Eagle, •..• ... Ponderosa Double Eagle Flat Tile ...... '.: .. 000.0• • 0000 • •• 0000• 0000•• • •• 0000• •• •• 0000 0000•• • •••••• • • • 0 • • 00.00• 0000•• • • • • • • • • 0000•• 0000 NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 4 of 10 Table 3: Restoring Moments due to Gravity - M9 (ft-lbf) Tile 311:12" 4":12" 5":12" 6":12" Greater than Profile 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7':12" Bel Air, Bel Air Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Double Eagle, 51.7 Deck 24.4 Deck 1-10d Smooth or Screw Shank Nail Field Clip) Deck 24.3 Deck 1-10d Smooth or Screw Shank Nail Eave Clip) Deck Ponderosa, 7.48 7.71 7.37 7.59 7.22 7.44 7.05 7.27 6.86 7.07 Golden Eagle, 2-10d Ring Shank Nails 50.3 65.5 •..#$'3 1. Installation with a 4" tile headiap and fastemers are located a min. of 2'/" from Meati Of tile.... Ponderosa Double Eagle Flat Tile Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Bel Air, Bel Air Double Eagle, Ponderosa, Golden 2-10d Ring Shank Nails 30.9 38.1 17.2 1-10d Smooth or Screw Shank Nail 7.3 9.8 4.9 2-10d Smooth or Screw Shank Nails 14.0 18.8 7.4 Eagle, Ponderosa 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 Double Eagle Flat Tile 1-10d Smooth or Screw Shank Nail Field Clip) 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Clip) 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails 50.3 65.5 •..#$'3 1. Installation with a 4" tile headiap and fastemers are located a min. of 2'/" from Meati Of tile.... 000.0• '•: 0000•• • 0000 •• • 0000 • •• 0000•• • •• •• •• 0000 0000•• • 0000•• •• • 0000 0000. 0000.. 0000• 0000• 0000•• • • • 0000•• •0000• NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 5 of 10 Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Resistance Bel Air, Bel Air Double Eagle, Adhesive 31.3 Ponderosa, Golden Eagle, Ponderosa Tile Double Eagle Flat Tile 3 Large paddy placement of 45 grams of Pol ProTm. 1 See manufactures component approval for installation requirements. 2 Flexible Products Company TileBond Average weight per patty 13.9 grams. 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Profile Resistance Bel Air, Bel Air Double Eagle, 3M 2 -Component Foam Roof Tile Adhesive AH -160 118.9 Ponderosa, Golden Eagle, 3M 2 -Component Foam Roof Tile Adhesive AH -160 40.4 Ponderosa Double Eagle Flat Tile 5 Tile-Tite Roof Tile Mortar. 3 Large paddy placement of 45 grams of Pol ProTm. 4 Medium paddy placement of 24 grams of Pol Prol*m. Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Bel Air, Bel Air Double Eagle, Ponderosa, Golden Mortar Set5 43.9 Eagle, Ponderosa Double Eagle Flat Tile 5 Tile-Tite Roof Tile Mortar. NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 6 of 10 . . .... ..•... ...... .. ...... .... . .. ..... • • ...... . .. ..... .. .. .... ...... ...... • . • . . . . ...... e • • • • 0000 NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 6 of 10 5. LABELING : All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or following statement: "Miami -Dade County Product Control Approved". EAG��� FLORIDA BEL AIR, BEL AIR DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT (LOCATED ON UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 this Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 7 of 10 . . .... ...... ...... .. ...... .... . .. ..... ...... . .. ..... . . .. .. .... ...... . . . ...... ._00" . ...... 0000 NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 7 of 10 PROFILE DRAWING BEL AIR BEL AIR DOUBLE EAGLE • 0000.• 0000.• .• .• ....•. 0000 • 0000 • . 0000•. . 0000 0000 0000•• • • 0000.• 0000.. 0000• 0000. 00•.00 • • • •..•.. ..••.• NOA No.: 12-0430.04 MIAMNDADE COUNTY gp. E iration Date: 10/05/16 • � � Approval Date: 08/02/12 Page 8 of 10 PONDEROSA PONDEROSA DOUBLE EAGLE 0000•• • 0000•• 0000 0000 0000•• 0000•• 0000 • 0000 • 0000•• 0000 0000.. • 0000.• 0000.• 0000• • 0000• 0000.• • 0000.. 0000.. NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 9 of 10 GOLDEN EAGLE END OF THIS ACCEPTANCE NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 10 of 10 00.0 0000 0000.. 0000.. .. 0000.. 0000.. 0000 •• • • • • • • • • 0000 • •• 0000• • - ••...• • •• 0000• •0 .0 0.•0 sees:* • ••••.•• • • • • .0000•• 0000.• • . • 0000•• •• • 0000 • • 0000 NOA No.: 12-0430.04 Expiration Date: 10/05/16 Approval Date: 08/02/12 Page 10 of 10 MIAMI•DADE :, MIAMI-DADE COUNTY ® PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3Mrm 2 -Component Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or ahonge in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endcltserpeit of anllproduct, for • • • • sales, advertising or any other purposes shall automatically terminate this NOA. Failure to c8lhpl� with-stption of •, this NOA shall be cause for termination and removal of NOA. """ ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flo lho-and fo�liowAd by thy: • expiration date maybe displayed in advertising literature. If any portion of the NOA is dis�yg4.then it sh1V be dory%: . • • . in its entirety. 669000 . .•�• **see* INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and..% shall be available for inspection at the job site at the request of the Building Official. • 00* • .. . .... This NOA revises NOA 12-0228.18 and consists of pages 1 through 11. s o % The submitted documentation was reviewed by Juan E. Collao, R.A. �aoE Courrrir NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement, and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3MTM 2 -Component Foam N/A TAS 101 Two component polyurethane foam adhesive Roof Tile Adhesive AH - 160 Foam Dispenser RTF 1000 N/A Dispensing Equipment ProPack® 30 & 100 N/A Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: • • •" •... 0000.. Prove Test Res>1 ' ' • Density ASTM D 1622 1.6 lbs./ft. • Compressive Strength ASTM D 1621 18 PSI Parallel to rise ""•' ;0000; 12 PSI Perpendicular to rise.•"'. Tensile Strength ASTM D 1623 0000 . .. 0000. 28 PSI Parallel to rise Water Absorption ASTM D 2127 0000.. . 0000. 0.08 Lbs./Ft2 • • •.. • Moisture Vapor Transmission ASTM E 96 as Ge 0900 sees.. 3.1 Perm / Inch • Dimensional Stability ASTM D 2126 *60006 e • +0.07% Volume Change @s40•F; 2 wegks Gees;. +6.0% Volume Change @ 158°F.,100% VWi ffty, 2 . G a . . 999009 weeks •• • •••• • Closed Cell Content ASTM D 2856 86% • • 9 • Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 13-0502.02 MuaMaouu cout�rtr . , . �LIApproval Expiration Date: 05/10/17 Date: 12/12/13 Page 2 of 11 EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-1 PA TAS 101 12/16/96 Trinity Engineering 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 ASTM D 1623 04/18/12 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 0""0 • 0000 0000•. 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assemely�foi fire ratiaj. • •' 2. All approved products listed herein shall be labeled and shall bear the imprint or identiiiaW&arking of Me 00 00" manufacturer's name or logo and following statement: "Miami -Dade County Product Ctar%t oi•ApprovO or the :see*: 0 0 .• . . 0 Miami -Dade County Product Control Seal as shown below. •• • • 0000 . 0 . . 0000.. . .... 0000•000. N1AM1•QADE COUNTY • • • • • APPROVED•• 00 0000 •00000 3. 3M' 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, IQN! P tigh tile profiles. • 0 4. Minimum underlayment shall be in compliance with the Roofing Application Standarc RAS 120. ; • • • • Goose* 5. Roof Tile manufactures acquiring acceptance for the use of 3M' 2 -Component Foam Roof Tile Adhe:i-."AH- : • • •: 160 roof file adhesive with their tile assemblies shall test in accordance with TAS 101. 0000 6. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 3 of 11 INSTALLATION: 1. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of 3MTm 2 -Component Foam Roof Tile Adhesive AH -160. 2. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA. 3. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTm 2 -Component Foam Roof Tile Adhesive AH - 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or ProPack® 30 & 100 dispensing equipment only. 7. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTm 2 - Component Foam Roof Tile Adhesive AH -160 has been dispensed. 9. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in accordance with the'Placement Details' herein. Each generic tile profile requires the specific placemeutipoted herein. 0 0 0000 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. .0000. NOA No.: 13-0502.02 MLAMM14DEC� Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 4 of 11 0000.. .. 0000.. 0000 •• 0 0 0 . . 0 0000 .. •• 0 . . . 00 00 0000 000000 0 0 0000.. 00 0 0000 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. .0000. NOA No.: 13-0502.02 MLAMM14DEC� Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram 0000.6 0 Area Weight Eave Course - Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy :06:0: head of tile 9-11 sq. inches at . 0 . . overlap 0000.. Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead 0000.. 00 0 0000 edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All 3M' 2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. 000• . . 0000 0000.6 0 6 BUILDING PERMIT REQUIREMENTS: • • 0000 • As required by the Building Official building in to t1ig 0iitallation lis **"0 or applicable code order properly evaluate of : system.*00000 0000 :0 0000 . .. 0000. 0 0 00 0.000 0 0 00 00 0000 00.0.0 :06:0: 00 . 0 . . 000000 0000.. 0 0 . 0 0000.. 00 0 0000 0 NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 (loll through plastic cement (when required) Paddy (Beneath Tile) I Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile.. 0.0.0 . . 0000 0000.. .. 4 666 6 6 6 004.60 .. 0000.. 666466 0000 .. 0000.. 6666 . 66 64660 High Profile / Single Pan TWO,, • •; .00. 0.6.0 66 66 6666 666666 1. Starting at the eave coudt,*J�jty a minirflum 2" • (50.8 mm) x 10" (254 mm) x 1'' (25.4 saw; foam paddy onto the underlay6nt positioned as shown: 6 6 6 6: 00 under the pan portion of a tile clos ssl #60o0the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 Nall through plastic cement When required) Paddy (Beneath Tile) Underlayment 1� 7in.2 ` Battens optional ° Ewe course loin. ai Eave Closure rough plastic cement required) Battens (Beneath Fascia Closure Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) —23(148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm2) -12 (77.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shwa? Wider the pan portion of the tile closest to bur overl3cV of the 000%6 tile being set. Insure approyiijit& 17 (W • *m2) — 23 (18.4 cm2) square inch.gve contact wrath the:****: underside of the tile. sees 0 0 :*so*: saes s •• ss•.• 2. At the second course, apply aomirbimum 2 ' (W.8mm�.:.. • x 7" (177.8 mm) x I" (25.44mr Foam pWanto the. - • a • underlayment positioned at OM under thti pan • • portion of the tile closest td the oderloc% pf Y%lr the • • • • • • being set. : .10. 0;....; 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm) square inch adhesive contact with the underside of the tile. (Instructions continued on nextpage) NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 7 of 11 ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm) square inch adhesive contact with the underside of the tile. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 8 of 11 0000 . . 0000 0000.. . • 0000.. 08 0080.6 088800 0 0 0 0000 088888 . .. 00000 0::::0000o .. 00808 00 80 8008 80088 0 .8..8. • • 000006. • 00 00.. 0 0 0 8 88888. 00 a 8080 NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 no PaftoetwemtfieQ SWAM t • • 0000 000..0 ...... .. ...... Ion x 0 0 0 0060 RaULOW Pftfft Tilt APPROVED On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 int (51.6-58.1 cm2) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 9 of 11 • • 0000 000..0 ...... .. ...... 000000 0 0 0 0060 .. 000.0. 6 6 0.00 • •• 00.06 • 0 0 0 0 •• •• 0000 •0006• •00.0• • • 0 • • • ••000• • • 0 • • •000•• 0 0 • •• • :*Go*: • •000• 0000 • NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) 4 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/a" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71 cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9(58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. MIAM4DADE cOUMY NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 10 of 11 (when tbetwmSeQ enc UOL �Mlzt to xbL 4 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/a" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cm2) - 11 (71 cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm2) - 9(58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. MIAM4DADE cOUMY NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 10 of 11 1? Place enough adhesive to achieve 65 to 701 In contact with the pan tile. 2) Tum covers upside down.Place adhesive in to 1 in from outside edge of cover tile. Then install the tile. Ensure 20 to'�%% 25 sq.IMcontact area,. . Underlayment I Eave closure (motar shown) Fascia ADHESIVE PLACEMENT DETAIL TWO PIECE BARREL 0 point -up Mortar on longitudinal edges of the Remove top portion of the cave course cover We. Abut to second course of pan tiles. Ensure eave end of pan and cover tiles are flush at eave line. Two Piece Barrel - High Profile rile Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) - 25 (161.3 cm2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured N osed • • • • • • foam adhesive. Pointingggf�lorggitudigil edges of so the cover tiles are consid%W� gptional... • 9999.• 960.0. 9 5. When additional nailing ie.required, l: (5A.8 mm}" x 4" (101.6 mm) nailers orthe'tie wise system ..... using galvanized, stainless•eAesgl, or cpppe elvire alter • • • compatible nails may beiftsd& • • • • 600600 9999.. 9999.. END OF THIS ACCEPTANCE •' g•" NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 11 of 11 Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andifeVowing statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.- 0 erein•0 . 666 RENEWAL of this NOA shall be considered after a renewal application has been filed and't air1las been no L•hange 0.600 • in the applicable building code negatively affecting the performance of this product. • 0 0 0 0 .. 6' :06600 000 6 6 6 • TERMINATION of this NOA will occur after the expiration date or if there has been a rev bs 6 o}' char a ip6 6he 0 0 6 6 • p 1�� .• Y� .0000 materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endor4ft0t of add PsQduct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to.o�mfly with ar6y section 0 of this NOA shall be cause for termination and removal of NOA. 0000.. 0000 • • 000 • 6 6 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County•Fldtida, and6R3iloweA 0.06 by the expiration date may be displayed in advertising literature. If any portion of the NOA is dispfayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 1 of 8 MIM MIAMI -DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGi1LATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aw/economy Polyglass USA Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Polystick Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andifeVowing statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.- 0 erein•0 . 666 RENEWAL of this NOA shall be considered after a renewal application has been filed and't air1las been no L•hange 0.600 • in the applicable building code negatively affecting the performance of this product. • 0 0 0 0 .. 6' :06600 000 6 6 6 • TERMINATION of this NOA will occur after the expiration date or if there has been a rev bs 6 o}' char a ip6 6he 0 0 6 6 • p 1�� .• Y� .0000 materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endor4ft0t of add PsQduct, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to.o�mfly with ar6y section 0 of this NOA shall be cause for termination and removal of NOA. 0000.. 0000 • • 000 • 6 6 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County•Fldtida, and6R3iloweA 0.06 by the expiration date may be displayed in advertising literature. If any portion of the NOA is dispfayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA #11-1229.01 and consists of pages 1 through 8. The submitted documentation was reviewed by Alex Tigera. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 1 of 8 ROOFING COMPONENT APPROVAL Category Roofing Sub -Category: Underlayment Material: SBS, APP Self -Adhering Modified Bitumen PRODUCTS DESCRIPTION: NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 Test Product Product Dimensions Specification Description Polystick MTS Roll: TAS 103 A homogeneous, rubberized asphalt underlayment 65'8" x 3'33/8" waterproofing membrane, glass fiber reinforced Manufacturing Location 60 mils thick with polyolefinic film on the upper surface for #2 use as an underlayment for metal roofing, roof tile, slate tiles and shingle underlayment. Polystick IR -Xe Roll: TAS 103 and A fine granular/sand top surface self -adhering, underlayment 65' x 3'33/8" ASTM D 1970 APP polymer modified, fiberglass reinforced, Manufacturing Location Or 65' x 3' bituminous sheet material for use as an #1 & #2 60 mils thick underlayment in sloped roof assemblies. Designed as an ice & rain shield and as a flat roof tile underlayment. Polystick TU Roll: TAS 103 and A heavy granuled surface self adhering, APP underlayment 32'10" x 3133/$" ASTM D 1970 polymer modified, fiberglass or polyester Manufacturing Location 100 mils thick reinforced, bituminous sheet material for use as #1 & #2 an underlayment in sloped roof assemblies. Designed as a a roof tile underlayment. Polystick TU Plus Roll: TAS 103 and A rubberized asphalt self -adhering, glq$; underlayment 65'x 3'33/8" ASTM D 1970 fiber/polyester reinforced waterproof. • ...... (Surface Printing) 80 mils thick membrane. Designed as acAeM rooiiag and roof Manufacturing Location the underlayment. • • • • • • • • 000000 #1 & #2 •••::*0. : . . Polystick TU P Roll: TAS 103 and .... . .. ..... A rubberized asphalt wat pswfing tnerabrane, ..:..' underlayment 32'l 0" x 3'33/8" ASTM D 1970 glass-fiber/polyester reir4o'oed, wit$ 4L;ranular ...... Manufacturing Location 130 mils thick surface designed for uslesgtle roof • • o #2 underlayment. 669606 0 00. Polystick Tile Pro Roll: TAS 103 and A rubberized asphalt self -adhering, gLis- Manufacturing Location 61' x 3933/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. Polystick Dual Pro Roll: TAS 103 and A rubberized asphalt self -adhering, glass - Manufacturing Location 6 P x 3'V/8" ASTM D 1970 fiber/polyester reinforced waterproofing #2 60 mils thick membrane. Designed as a metal roofing and roof tile underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 2 of 8 PRODUCTS DESCRIPTION: Test Product Product Dimensions Specification Description Polystick TU Max Roll: TAS 103 and A rubberized asphalt self -adhering, polyester Manufacturing Location 65'8" x 3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed #2 60 mils thick as a a roof tile underlayment. MANUFACTURING PLANTS: 1.Hazelton, PA 2.Winter Haven, FL EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date Exterior Research & Design, LLC 11756.04.01-1 TAS 103 04/27/01 11756.08.01-1 ASTM D 1970 08/14/01 02202.08.05 TAS 103 08/29/05 Trinity I ERD P5110.08.07 TAS 103 08/29/07 P10870.09.08 -R1 TAS 103 12/04/08 P10870.04.09 TAS 103/ASTM D4798 & G155 04/13/09 P33360.06.10 ASTM D1970 07/01/10 P33370.03.11 TAS 103 03/02/11 P33370.04.11 ASTM D 1623 04/26/11 P36900.09.11 TAS 103/ASTM D4798 & G155 09/01/11 P37300.10.11 TAS 110/ASTM D4798 & D1970 10/19/11 P40390.08.12-1 TAS 103 & TAS 110 08/06/12 P40390.08.12-2 ASTM D 1623 08/07/12 P40390.10.12 ASTM D 1970 10/03/12 PRI Asphalt Technologies PRI01 I I I ASTM D 4977 ®4/'0.8*J82 PUSA-005-02-01 ASTM D 4977 '.. • Ql/.31/02 PUSA-018-02-01 ASTM D 2523 ...... 07/1'4103 PUSA-035-02-01 TAS 103 • • • % • • 09/39/06 PUSA-033-02-01 ASTM D 1970 . • • • • . 0 /.l YQ6 PUSA-055-02-02 TAS 103 "" 12/14/07 PUSA-083-02-01 TAS 103 06/.3'/08 PUSA-089-02-01 TAS 103/ASTM D4798 & V15r 01%r;/09 Momentum Technologies, Inc. JX20H7A • TAS 103/ASTM D4798 & f 155 ; Q4/OV08 RX14E8A TAS 103/ASTM D4798 & G155. :??"/179 DX2313813 TAS 103/ASTM D4798 & NA : 021&40 DX231)8A TAS 103/ASTM D4798 & G155 601,8/10 NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 3 of 8 INSTALLATION PROCEDURES: Deck Type 1: Wood, non -insulated Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626. Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for base sheet only) Membrane: Polystick membranes self -adhered. Surfacing: None 1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels, and sweep the deck thoroughly to remove any dust and debris prior to application. 2. Place the underlayment over metal drip edge in accordance with RAS 111. 3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact. Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-1/2" and end laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code. 4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. 5. For ridge applications, center the membrane and roll from the center outward in both directions. 6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to lap areas. 7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance. 8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be applied over the underlayment. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 4 of 8 0000 ...... 000000 . . 00. 00.. 0000 .. 0000 . .. 0000. 0000.. . .. 0000. . . . . 0 .. .. .... 0000.. . ...... so . . . . 0000.. ...... o . . .0000. .. 0 0000 . . NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 4 of 8 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR -Xe, TU, and TU P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in roof tile systems only. 3. Deck requirements shall be in compliance with applicable building code. 4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities. 5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof membrane as a recover system. 6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the preceeding maximum time limitations. Exposure Limitations (days) MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro TU Max Winter Haven, FL. 180 180 180 180 180 180 180 90 Hazelton, PA. N/A 30 30 180 N/A N/A N/A N/A 7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile applications with the exception of mortar set tile applications. 9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shjLtlelse4s follows: (See Table Below) .000.. .000.0 Tile Profile Polystick MTS Polystick IR -Xe Polystick TU, +W: PolystlWFU Plus, TU P, Tllle . Mfx Pro 0000 :'. '. Flat Tile Prohibited without 5:12 No limitation... No limittion battens• .. 0000 Profiled Tile Prohibited without Prohibited No limitation' •; No limitation battens a0 0 I I ... - 000000 0000 0000. .000.0 ..0000 The above slope limitations can be exceeded only by using battens and counter battens in accordanle vAth tha • • • • Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements' •EAttens are required for both loading and installation of tiles at all times. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 5 of 8 GENERAL LIMITATIONS: (CONTINUED) 10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all underlayments except Polystick MTS which shall be loaded onto battens. m CL 0 N r i0 Roofing Tiles (6 Max Per Stack) 12 s 11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. LABELING: 1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's ngm dor logo, city and state of manufacturing facility and the following statement: "Miami-Dadg CoVnty PrOdUrt,Eontroj,,,,, Approved" or the Miami -Dade County Product Control Seal as shown below. '..' 6.6 6 6..0.. .. 0606.6 MIAMHMDE COUPiTY • ,...• 666660 6666.. 6000 .0 6 6 6 . . 6666 . .. .6666 BUILDING PERMIT REQUIREMENTS: . 6.6.6 • • • , •; 6 6 Application for building permit shall be accompanied by copies of the following: •. .. .0.0 .. 6.6.6. • • 1. This Notice of Acceptance. : 0 : + 6 6 ..6:. 0000++ 2. Any other documents required by the Building Official or applicable building code in a idertaproperly: *Goo aluate • • • 6 the installation of this materials. 66;6 NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 6 of 8 POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES: 1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable. Please also refer to applicable Product Data Sheets of the corresponding products. 2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being back -nailed. (Please refer to applicable local building codes prior to installation.) 3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact. 4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic between the laps does not apply to Polystick MTS. 5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile Loading Guidelines. See General Limitations #9 and #10. 6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions should be taken, such as the use of battens to prevent tile sliding during the loading process. 7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours. 8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed roof to wall details. 9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing Cement to the area in need of repair, followed by a patch of the Polystick material of like kind s1y11181V set and hand rolled in place over the area needing such repair. Patching membrane shal:bee minimuiWdf6 "'•:' inches in either direction. The repair should be installed in such a way so that water will run para%el•toor •. •00.00 •• •••s•• over the top of all laps of the patch. 00000* • 10. All self -adhered membranes must be rolled to ensure full contact with approved subsTMN Polygl%ss• • • requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrWe *Hand rbllef?are . ... . acceptable for rolling of patches or small areas of the roof. Brooming may be used w .s.lope p X ..... 001 its *of*:* rolling. 0000•• • 11. All approved substrates should be dry, clean and properly prepared, before any application of Poet t • • • • % • membranes commences. An approved substrate technical bulletin can be famished.1ipciftequesf It is ;. • • •; recommended to refer to applicable building codes prior to installation to verify accetlablt substrata • • • 12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and *09 PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800) 894-4563. NOA No.: 12-0713.02 Expiration Date: 09/13/16 Approval Date: 02/14/13 Page 7 of 8 13. Questions in regards to the application of Polyglass products should be directed to our Technical Services Department at 1 (800) 894-4563. 14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by the National Roofing Contractors Association (NRCA). PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS. END OF THIS ACCEPTANCE 0000 . . . . .... 006..0 0.: 0000.. 0000.. 0000.. 0 0 0000.. 00 0 0 .. 0 , .. 0000 . ... 00000 0000.. . .0 0000. . .. . ,0 0. 0000 0000.. 9 0000.. . . . , 6990.0 0000.. 9 . .. 0000.. .0 9 .009 . 0 0000 CMt•OU1DE=FM NOA No.: 12-0713.02 � Expiration Date: 09/13/16 M. Approval Date: 02/14/13 Page 8 of 8 Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks • • • • • • • • • ° • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,•vity,eAate and fol0wing • • • • % • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein' • • ° • • ; ° ° ° °; • • RENEWAL of this NOA shall be considered after a renewal a • • ° • ben o • •chane • • • • application has been filed and.has >r nL. g ..:..' in the applicable building code negatively affecting the performance of this product. •.:..' ...... TERMINATION of this NOA will occur after the expiration date or if there has been a reAsion Or chat1gAV le • • • • • materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsetaient of any product, :....: for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to cote ply with a0 y section • of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0818.07 and consists of pages 1 through 26. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 1 of 26 MIAM0MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMIMSTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks • • • • • • • • • ° • • LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,•vity,eAate and fol0wing • • • • % • statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein' • • ° • • ; ° ° ° °; • • RENEWAL of this NOA shall be considered after a renewal a • • ° • ben o • •chane • • • • application has been filed and.has >r nL. g ..:..' in the applicable building code negatively affecting the performance of this product. •.:..' ...... TERMINATION of this NOA will occur after the expiration date or if there has been a reAsion Or chat1gAV le • • • • • materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsetaient of any product, :....: for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to cote ply with a0 y section • of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0818.07 and consists of pages 1 through 26. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 1 of 26 ROOFING ASSEMBLY APPROVAL Cateifory' Roofing Sub-Catellorv: Modified Bitumen Materials SBS/APP/TPO Deck Tybe• Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Elastobase 65' 2" x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced Type I base sheet. Elastobase P 5' 2" x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base Type I sheet. Elastoflex SA V FR 32' 6" x 3' 3-3/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified (1.5 -mm) Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA V 32' 6" x 3' 3-3/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified PLUS FR Type I bitumen membrane with a self -adhering back face and a smooth top surface. Elastoflex SA V (1.5- 32' 6" x 3' 33/g" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS wpjified mm) Type I bitumen membrane with a self-adhering%aekface and..... a smooth top surface. • • • • • • Elastoflex SA V 32'6"x3'3_3 /8" ASTM D 6163 fiber Self -adhered lass rei• or.gc SBS modified • g � . PLUS Type I bitumen membrane with a sqj f dohering,back face ano• • • •; a smooth top surface. '90000 a : *00* ..••• Elastoflex SA P FR 32' 6" x 3' 3-3/8" ASTM D 6164, Self -adhered, polyester reirfftddd3 SBS 3nodiFied 0000' Type I bitumen membrane with a self-aahering back face ana9. •: • a granule top surface.• Elastoflex SA P 32' 6" x 3' 3-3/8" ASTM D 6164, • • • • 090.00 Self -adhered, fiberglass rei;forye� SBS•modified Type I • �; bitumen membrane with a sdlt'-adhering bapitOfte and • a granule top surface. 0000 Polyflex SA P 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyflex SA P FR 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko SBS SAP 32' 6" x 3' 33/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified Type I bitumen membrane with a self -adhering back face and a granule top surface. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 2 of 26 Polyfresko SBS SAP 32' 6" x 3' 33/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified FR Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko APP SAP 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a granule top surface. Polyfresko APP SAP 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified FR Type I bitumen membrane with a self -adhering back face and a granule top surface PolyKool 32' 10" x 3' 33/8" ASTM D6222 Self -adhered, polyester reinforced, APP modified Type I bitumen membrane with a self -adhering back face and a white film laminate on the top surface. PG-' 25 Cold Process 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or Adhesive tube Type III BUR roofing. PG 100 Asphalt Primer 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 17 oz. spray selected asphalts used to promote adhesion. can PG350 Mod Bit 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Adhesive tube Type III modified bitumen membranes. PG400 Plastic Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG425 Wet/Dry Roof 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. PG450 Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flasjiing celt8e44.* • • • • • • • Cement tube . . ' 0000 : PG500 MB Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberizefl'f;Vhing cement far use Cement tube with modified bitumen mefn'branes. :....: Polyplus 35 Premium 1, 3, 5, 50, 55 gal. or ASTM D3019 .... .. A fibered rubberized adhesiveclesigne&or4se with ...... Mod Bit Adhesive tube Type III modified bitumen membrantp •; ••••• Polyplus 45 Premium 1 3 5 50 55 al. or ASTM D4586 0090 A thick,fibered rubberize • * • n ceme • • • • �' Flashing Cement tube' • • . . . . ...... Polyplus 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberizeV flas%ng cetiient for use ;....; MB Flashing Cement tube with modified bitumen memTrangs. ."' ' Polyplus 55 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 .... A mastic compound for use as a roof flashing Modified Flashing tube adhesive. Cement NOA No.: 13-0514,10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 3 of 26 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Polytherm-H Polyisocyanurate foam insulation Polytherm Polyisocyanurate foam insulation Polytherm Composite Polyisocyanurate/perlite composite insulation. ACFoam-II Polyisocyanurate foam insulation ACFoam-III Polyisocyanurate foam insulation High Density Wood Fiberboard Wood fiber insulation board Perlite Insulation Perlite insulation board Type X Gypsum Fire resistant rated gypsum. DensDeck, DensDeck Prime Gypsum insulation board H -Shield Polyisocyanurate foam insulation H -Shield CG Polyisocyanurate/perlite composite insulation ENRGY-3, JM ISO 3 Fesco Board Multi -Max FA -3 SECUROCK Gypsum -Fiber Roof Board Polyisocyanurate foam insulation Expanded mineral fiber Polyisocyanurate foam insulation Fiber reinforced coverboard Manufacturer (With Current NOA) Polyglass USA, Inc. Polyglass USA, Inc. Polyglass USA, Inc. Atlas Roofing Corp Atlas Roofing Corp Generic Generic Generic Georgia-Pacific Hunter Panels, LLC Hunter Panels, LLC Johns Manville Corp. Johns Manville Corp. Rmax Opera 4k" LLC. . . .. . ... • United States (!yUsum ...• 9 • • • • *.CorpOratll7p: 6669:9 • 040••9 • • • •94.0• *006 0 4.4• • •• • 4 •0000 •4994• • •• 04440 • 0 9 0 4 •• •0 04•6 •4.44• • •04.99 • on • - • • 4.4944 94••9• 9 0 4 949400 0000 NOA No.: 13-0514.10 Mu1MMADeCOUNW Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 4 of 26 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast Fasteners #l2, #14 Insulation fastener for wood, SFS Intec, Inc. & #15 HS steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2 7/8" x SFS Intec, Inc. Hex Plate 31/411 3. Dekfast Dekflat Round Polypropylene locking 3" x 3 '/4" SFS Intec, Inc. Plastic Lock Plate plate. 4. #12 & #14 Roofgrip Insulation and membrane Various OMG, Inc. fastener 5. Flat Bottom Metal Plate A2 -SS aluminized steel plate 3" square OMG, Inc. 6. Plastic Plate Polyethylene stress plate 3.2" round OMG, Inc. 7. Tru -Fast #14 HD Fastener Insulation fastener for steel and Altenloh, Brinck & Co. wood decks U.S., Inc. 8. Tru -Fast 3" Metal Insulation Round Galvalume AZ50 steel 3.23 round Altenloh, Brinck & Co. Plate plate 3" round U.S., Inc. 9. Polygrip Fasteners # 12, # 14 Insulation fastener for wood, Various Polyglac a MA, Inc &#15 steel and concrete decks 00000. • 10. Polygrip Hex Plates Galvalume hex stress plate. 2 7/8" x • • •: 4lyglass ORA, Inc • • • • � • 3 I/4" 000000 0000.. 11. Dekfast Galvalume Steel 3 3" round galvalume AZ50 steel 3" round .. 0:::: -SFS Iht@�,�nc. • • • • . in. Round plate 12. Millennium One-Step� Insulation Adhesive Various .. .. 0000.. Adco 19?c dhcts 6 Foamable Adhesive • • • • • • • • . . . . . 0 ...... 0009 . 6 6 .6060. .0 . 6000 6 . 00*0 MIAMFDADE COUNTY NOA No.: 13-0514.10 ... � Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 5 of 26 APPROVED SURFACING: TABLE 4 Product Product Name Description PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used to add life and rejuvenate existing BUR roofing substrates. PG300 Fibered Roof Coating An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR PG600 Non-Fibered Aluminum Roof Coating PG650 Fibered Aluminum Roof Coating PG700 White Elastomeric Roof Coating Application Specification Manufactur Rate er 1'/Z-2 gal/sq TAS 140 Polyglass Polyplus 65 Premium Fibered USA, Inc. 1'/2-2 gal/sq ASTM D4479 Polyglass Polyplus 60 Premium Non- USA, Inc. Non-fibered aluminum roof coating. '/2-1 gal/sq Fibered aluminum roof coating. 1'/2-2 gal/sq A premium white elastomeric acrylic 1-1'/Z gaUsq based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. PG800 Non-Fibered Asphalt An asphalt base, un-fibered clay Emulsion Roof Coating emulsion PG850 Fibered Asphalt Emulsion An asphalt base, fibered clay Roof Coating emulsion Polyplus 65 Premium Fibered Fibered aluminum roof coating. Aluminum Roof Coating Polyglass Polyplus 60 Premium Non- Non-fibered aluminum roof coating. Fibered Aluminum Roof Coating ASIM 132824 Polybrite 70 White Elastomeric Roof Coating Gravel Slag A premium white elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. To be installed in a flood coat of approved asphalt at 60 lbs/sq To be installed in a flood coat of approved asphalt at 60 lbs/sq ASTM D2824 Polyglass Type I USA, Inc. ASTM D2824 Polyglass Type III USA, Inc. ASTM D6083 Polyglass USA, Inc. 3 gal/sq in ASTM D1227 Polyglass two coats USA, Inc. 3 gal/sq in ASTM D 1227• Polyglass two coats • ..jT.S'A, Inc,... 1'/2-2 gal/sq ASIM 132824 • • • Pojyglass • . " i' pill USA, Inc. ""' '/Z-1 gal/sq •..... ASTAQA2824.. • . Polyglast 00 • •79ype I : ' VT A, Inc* • • • • •••••• . .. .•..• 1-1'/Z gal/sq . .. Aye**p6083 ... *.olyglass....••.. ' USA,Inc,,,.:, • . • • . 400 lbs/sq N/A • • • •Generic 300lbs/sq N/A Generic t�uwtt DAae coun�r�r NOA No.: 13-0514.10 ... • Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 6 of 26 EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 J.I.2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 J.1.3001334 02.15.00 4470 J.I.3000857 01.12.00 4470 J.I.3004091 01.12.00 4470 3012321 07.29.07 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3014692 08.05.03 Trinity ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 02764.09.05 09.09.05 TAS 114 020843.02.05-1 02.10.05 TAS 114 02762.03.05 03.30.05 TAS 117(B) -ASTM D903 020841.06.04 06.02.04 TAS 114 P1734.07.06 -R1 02.27.07 TAS 114 02843.07.07 07.23.07 TAS 114 P1738.02.07 02.05.07 TAS 114 P1739.01.07 01.23.07 TAS 117(B) -ASTM D6862 C8500SC.11.07 11.30.07 ASTM D6164 / ASTM D6222 P10490.08.08 08.13.08 ASTM D6164 / ASTM D6222 P10490.10.08 -RI .IV.63.08 ASTM D6222 P7400.03.08-RZ .. lei/8g/08 TAS 114(D) — ASTM D 1876 P10070.10.08 *f0/99,t48 ASTM D6222 P 10490.10.08-2r : : : : : 10/30/08 FM 4470 & TAS 114 P33970.03.11 .... ,Q3/15/1 I ASTM D6163 / ASTM D 4601 P33960.03.11 '.... * :V14SA 1 ASTM D6164 P37590.07.13-1• •: a e: V7 j92/13 ASTM D6164 P37590.03.13-3Ae • • 09f@6/13 ASTM D6163 P37590.03.13 -2-$f':': 02/05/13 ASTM D6222 P37590.09.13 0 :(1`WoM3 PRI Asphalt Technologies ASTM D6222 PUSA-061-02-02�e Oj:28/08 ASTM D6222 PUSA-062-02-02 12/04/08 ASTM D6163 PUSA-064-02-02 02/27/08 sees.. ..sees 0 e .6000. 066. . . sees. sees.. •.0060 00..00 0 e MIAMI•DADE c � NOA No.: 13-0514.10 � � Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 7 of 26 APPROVED ASSEMBLIES: Membrane Type: SBS/APP Deck Type II: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of Elastobase or an ASTM D4601, Type H approved base sheet fastened to the deck as described below: Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet. Fastening #2: Attach base sheet using OMG Roofgrip Fasteners and Flat Bottom Plates, Dekfast #14 with Galvalume Steel Hex Plates or Polygrip Fasteners #14 with Polygrip Hex Plates or Tru -Fast #14 HD Fasteners with 3" Metal Insulation Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following Base Insulation Laver (Optional) Insulation Fasteners Fastener able 3 . i;'eWl /ft' . . ... ...... Any approved Polyisocyanurate listed in Table 2 • Minimum l" thick N/A •••••• •N;A ••••�• Note: All insulation shall be adhered to the anchor sheet in full mopping of approved°1184 asphi t°within tIfe EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application"Sfandard UW 117 for : • 6 • insulation attachment. Insulation listed as base layer only shall be used only as base lra�crs *with a s®eond layer . • 0. .0 0000 ...... of approved top layer insulation installed as the final membrane substrate. Compositejgsulgtion panels may be •• used as a top layer placed with the polyisocyanurate side facing down. ....:. Top Insulation Laver Insulation Fastener Fastener • • •. able 3 •Bt>f�tz DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum 1/" thick N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self -adhered. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 8 of 26 Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf, (See general limitation #7.) • • •Y•• •••0•• •0000• •• 0000•0 • 600000 i • • 0000 •• • • • • • • • • 00 • •00.0• • • • • • • •000•• • • • • •00000 fees NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 9 of 26 Membrane Type: Deck Type 1I: SBS/APP Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood screws at 6" o.c. System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System limitations apply. Anchor Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below: Fastening: Attach base sheet using OMG Roofgrip Fasteners and Flat Bottom Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following Base Insulation Laver (Optional) Insulation Fasteners Fastener able 3 Density/W Any approved Polyisocyanurate listed in Table 2 Minimum 1" thick N/A NIA Top Insulation Laver Insulation Fasteners Fastener able 3 Density/fe DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board .••••. Minimum'/" thick N/A ••• •••1\/A ••••�• 0 . 0 000000 .. 000000 Note: All insulation shall be adhered to the anchor sheet in full mopping of approvgd.Qat asphalt within the EVT range and at a rate of 2040 lbs/100 W. Please refer to Roofing Application*Standard 44AS.117 for' 0 • • insulation attachment. Insulation listed as base layer only shall be used only as base fayws with aseom;d layer;••• of approved top layer insulation installed as the final membrane substrate. Composite"#tion l3a4el9 jnay 000••• used as a top layer placed with the polyisocyanurate side facing down. 00 00 0000 000000 0000.. . • Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V 17146Cr•'0• 06•••, Elastoflex SA V PLUS FR self -adhered. •.. • • 0000 """ 00:0 Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See general limitation #7.) NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 10 of 26 Membrane Type: Deck Type 1I: SBS/APP Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood screws at 6" o.c. System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of an ASTM D4601, Type II approved base sheet fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet. One of more of the following: Base Insulation Laver (Optional) Insulation Fasteners Fastener able 3 Density/fe Any approved Polyisocyanurate listed in Table 2 Minimum 1" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. .... . . .... ...... Top Insulation Laver Insulation Fasteners • •P s uer (Table3) • • • ; • • Deni" /ftz Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board • • • Minimum '/e" thick N/A : 0 491A • • • • • ...... . .. ..... Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the'EVT ranglr and at a rate of 2040 lbs/100 W. Please refer to Roofing Application Standard:IM:117 for Insulation '. attachment. Insulation listed as Base Layer only shall be used only as base layer§ with' a se&md layer of� • • • approved top layer insulation installed as the final membrane substrate. Composite U �uiation panej%Viay b�• • • •; used as a top layer placed with the polyisocyanurate side facing down. so:* Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self -adhered. Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 11 of 26 Maximum Design Pressure: -60 psf; (See general limitation #7.) NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 12 of 26 0000 . . 0000 0000.. 0000.. 0000.. 0000 .. 0000 .. ..0.. ...... .. .0...0 .. .. 0000 0000.0 .....•. 00 . . 0000.. 0000.. . 0000.. .. .0.. 0000 NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 12 of 26 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32° or greater plywood or wood plank. System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of Elastobase or Elastobase P fastened as below: Fastening: 12 ga. Annular ring shank nails and 1-5/8" tin -caps attached 6" o.c. in 4" lap and 6" o.c. in four equally spaced staggered rows. Base Insulation Laver Insulation Fasteners Fastener able 3 Density/ftp Polytherm, ACFoam II, ACFoam III, Polytherm-H, H -Shield, H -Shield CG, Multi -Max FA3, or ENRGY-3 Minimum 1" thick N/A N/A Insulation: Adhered with Millenium One -Step Foamable Adhesive applied over rows of tin -caps in continuous rows 7" o.c. Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self -adhered. Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polr)da: SA P FR self adhered. • • • • *go::* •••;• Surfacing: (Optional) Install one of the approved surfacing products listed in TaUlE Vfb obtain desi$id *Gone* coating or required fire classification. 000000 e • ...... .... . •• •••.• Maximum Design . • • • • • • go ..:..' Pressure: Pressure: - -60 psf; (See general limitation #7.)' • • • • • • . . . . ..e... MIAMPDADE CJNOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 13 of 26 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type C(1): All layers of insulation are mechanically attached to roof deck. Membrane is subsequently adhered to insulation. All General and System Limitations apply. One or more of the following Base Insulation Laver Any approved Polyisocyanurate listed in Table 2 Minimum 1.5" thick Insulation Fasteners Fastener able 3 Density/fe N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Toa Insulation Laver Approved High Density Wood Fiber Minimum 1/2" thick Insulation Fasteners Fastener able 3 Density/ft2 1:1.33 ftz DensDeck • •••• Minimum 1/4" thick l 009 7:io33 ftz "":' Go . Geo G • Note: All layers of insulation shall be mechanically attached using the fastener Je*n*s*IF listed algove. Th"".. ge • insulation panels listed are minimum sizes and dimensions; if larger panels are used* iog jsumber of i[asteneiV `: shall be increased maintaining the same fastener density. Please refer to Roofing Appjption Staddafd RA& G G e 117 for insulation attachment. .Goose 00 09:000 • . . G Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastolex M V FR, or* Elastoflex SA V PLUS FR self -adhered. :...:. e Soso 0 Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SLAP, Pgl o esko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation #7.) NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 14 of 26 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32° or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. System Type C(2): All layers of insulation are mechanically attached to roof deck. Membrane is subsequently adhered to insulation. All General and System Limitations apply. One or more layers of the following: Base Insulation Laver Any approved Polyisocyanurate listed in Table 2 Minimum 1.5" thick Insulation Fasteners Fastener able 3 Density/fe N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Ton Insulation Laver Approved High Density Wood Fiber Minimum %" thick DensDeck Minimum '/a" thick Insulation Fasteners Fastener able 3 Density/W 1:1.33 ft2 1:1.33 W Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. 000000 •••"' Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, ElastoR" f" V FR, or " ""' • Elastoflex SA V PLUS FR self -adhered. """ % • • • • 0 • . 0 . 0 . .. 0000. Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko �►��' SAP, Pplyfr%sko . •;..' ..•00• APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, P4yl�,ifl or PdIVUYSA P .00 0 0 0 FR self adhered. 0000.. • • . . . . .0000• 0000.. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to pbtainodesired ;..... coating or required fire classification. .. . 0000 0 • .00• Maximum Design Pressure: -67.5 psf; (See General limitation #7.) NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 15 of 26 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened with wood screws at 6" o.c. System Type C(3): All layers of insulation are mechanically attached to roof deck. Membrane is subsequently adhered to insulation. All General and System Limitations apply. One or more of the following: Insulation Laver ENRGY-3, Polytherm-H, H -Shield or Polytherm Minimum 1.5" thick Insulation Fasteners Fastener Table 3 Density/ft2 1,7or9 1:1.33W Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self -adhered. Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. 9999 Maximum Design ' 9999. . • 9999 • Pressure: -82.5 psf; (See General limitation #7.) 900.90 00 9900.0 090000 9999.. 0009 .. . . . . 9999 .. .. ..�� 00900. . .0 9.0.9 . 9 . 90 00 9999 9999.. . ...9.9 04, • 0 . . 00..0. 9999.. 9 966 9999.. 09 0 0000 0 • - NOA No.: 13-0514.10 MIAMMDADECOUNTY � ® Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 16 of 26 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type D(1): All layers of insulation and base sheet simultaneously attached, membrane subsequently adhered.. All General and System Limitations apply. One or more layers of the following: Base Insulation Laver Any approved Polyisocyanurate listed in Tablet Minimum 1" thick Ton Insulation Laver (Optional) Fesco Board Minimum '/" thick Approved High Density Wood Fiber Minimum 1/2" thick DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum 1/" thick Insulation Fasteners Fastener able 3 Density/fe N/A N/A Insulation Fasteners Fastener able 3 Density/W N/A N/A N/A N/A N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One or more plies of Elastobase or Elastobase P fastened to the deck as described beloVA . . 0000 0000.. Fastening: Attach base sheet using OMG # 14 Roofgrip Fasteners and Flat Bottom dates, DekfM.#1; with Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygdo "ex Plates of Trufasi"• � • #14 HD Fasteners with 3" Metal Insulation Plates spaced 12" o.c. in a'40 �l'ai'and 12'� o in twa • • • • equally spaced staggered rows in the center of the sheet. • 09990 Ply Sheet: 0000.. . .. 0000.• One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastotle0� 50V FR' o$ .. 000 9 • Elastoflex SA V PLUS FR self -adhered. 0 9 0 0 0 9 9 •• • 0 . . . . 000000 Membrane: 0000.. One ply ofPolyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko�PVW, P8lyfresko :0909: APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PoI jKooi or Polyflex %A P 0 0000 FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 17 of 26 Maximum Design Pressure: -52.5 psf; (See General limitation #7.) NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 18 of 26 0000 . . 0.06 .00..0 .0000. .. 0060.0 000.0. 0000.. 0000 .. 6 . . .•.• 0000 .0000 . 000000 0000 0000.9 .....0 on . 0000.. ...... 6 .0000. .. 0000 0*06 NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 18 of 26 Membrane Type: Deck Type 1I: SBS/APP Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood screws at 6" o.c. System Type D(2): All layers of insulation and base sheet mechanically fastened, membrane subsequently adhered. All General and System Limitations apply. One or more layers of the following: Base Insulation Laver Any approved Polyisocyanurate listed in Table 2 Minimum 1" thick Top Insulation Laver (Optional) Fesco Board Minimum %" thick Approved High Density Wood Fiber Minimum %" thick DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board Minimum'/" thick Insulation Fasteners Fastener able 3 Density/fe N/A N/A Insulation Fasteners Fastener able 3 Density/ft2 N/A N/A N/A N/A N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One or more plies of Elastobase or Elastobase P fastened to the deck as described bejQy, . 0000 0.0000 Fastening: Attach base sheet using OMG Roofgrip Fasteners and Flat Bottom Plaiw0pked lNgoc . in a 4" • ee lap and 12" o.c. in two equally spaced staggered rows in the center of th&shaet. • • 006000 000000 0 0 Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastolj2at S%V FR; bs '. 0000.. Elastoflex SA V PLUS FR self -adhered. "' • Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko jl+V&P, PolAesko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PcgyKboi or Pclyflex SA P . • • •: • FR self adhered. : * s o 00 0 0000 0000.. 0 Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain%%I� ed coating or required fire classification. Maximum Design Pressure: -60 psf; (See General limitation #7.) NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 19 of 26 Membrane Type: SBS/APP Deck Type 1: Wood, Non -Insulated Deck Description: 19/32" or greater plywood or wood plank. System Type E(1): Base sheet is mechanically attached to roof deck. All General and System Limitations apply. Base Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below: Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c. in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet. Fastening #2: Attach base sheet using OMG #14 Roofgrip Fasteners and Flat Bottom Plates, Dekfast #14 with Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygrip Hex Plates or Trufast #14 HD Fasteners with 3" Metal Insulation Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or Elastoflex SA V PLUS FR self -adhered. Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P FR self adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation #7.). 0000 . . 0000 0000.. 0000.. 0000.. 0000 .. 0000 . .. 0000. •• •• 0000 0000:9 000000 • • • • • 00000• •00000 • • • 00000• •• • 0000 • • • 0000 NOA No.: 13-0514.10 MInMMAD, COUNTY Expiration Date: 10/11/17 �ffjumApproval Date: 09/26/13 Page 20 of 26 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20401bs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registeredeiWessional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is'secificaRy •referredr • • • within this NOA, General Limitation #9 will not be applicable.) ' • •' • • • • • '. 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing terminatict edogns shall coflfbrm td Roofing Application Standard RAS I 1 I and applicable wind load requirements. • • •"' :....: 9. The maximum designed pressure limitation listed shall be applicable to all roof pressurs'21oV c (i.e. few • • • �' 49 perimeters, and corners). Neither rational analysis, nor extrapolation shall be permittedfo;:6anceifasl%ping at. •;• • enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this ligytoAdn is spe. f filly *fee:* referred within this NOA, General Limitation #7 will not be applicable.) e 00:6: • . e . . ....e. ee.e.. END OF THIS ACCEPTANCE •' • • • • • •• • ecce • • • ecce NOA No.: 13-0514.10 Expiration Date: 10/11/17 Approval Date: 09/26/13 Page 26 of 26 TdU.R14571 - Roofing Systems http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/Showpa... "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT' (self adhered). Ply Sheet (Optional): — "ELASTOBASE", "XtraFlex SBS GLASS Base"(poly/sand), heat fused or mechanically fastened, or "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", "ELASTOFLEX SA V FR HT", (self adhered) or "POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "POLYFRESKO G FR", "DUFLEX G FR", "XtraFlex APP Dual", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G "XtraFlex SBS POLY G T, .4DA144X.55S.QIAUQG—'"Xtr-aFlax St3S-GLASS GT' or "ELASTOSHIELD TS G FR", heat fused. 22. Deck: C-15/32 Incline: 1/2 Insulation (Optional): — Polylsocyanurate 1.5 in. (min.) with all joints staggered 6 -in. (min.) from the plywood joints. Base Sheet: — Type G2, mechanically fastened followed by "ELASTOBASE", "XtraFlex SBS GLASS Base", mechanically fastened. Ply Sheet (Optional): — "ELASTOFLEX SA V PLUS FR" , "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", or "DUFLEX G FR", "XtraFlex APP Dual", "POLYFLD( G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY GT', "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or "ELASTOSHIELD TS G FR", heat fused. 23. Deck- NC Incline: 2 Insulation (Optional): — Atlas Roofing "ACFoam III" or "ACFoam Ir or Hunter Panels "H -Shield", any thickness. Base Sheet: — "ELASTOBASE", "XtraFlex SBS GLASS Base"(poly/sand), heat fused or mechanically fastened or "ELASTOFLEX SAV FR", "ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT', (self adhered). Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", "ELASTOFLEX SA V FR HT', (self adhered) or "POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "POLYFRESKO G FR", "XtraFlex APP Duar, "DUFLEX G FR" "ELASTOFLEX S6 G FR',-"POLYFRESKO G SBS FR", "ELASTOFLEX VGFR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T, "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or" ELASTOSHIELD TS G FR", heat fused. 24. Deck: C-15/32 Incline: 3 Insulation (Optional): — Polylsocyanurate, perllte, wood fiber or polyisocyanurate/periite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck@, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — "ELASTOBASE", "XtraFlex SBS GLASS Base" (poly/sand), mechanically fastened. Ply Sheet (Optional): — "ELASTOFLEX SA V PLUS FR" , "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: — "ELASTOFLD( S6 G FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T" or "POLYFRESKO G SBS FR", heat fused. 25. Deck: NC Incline: 3 Insulation (Optional) Atlas Roofing "ACFoam III" or "ACFoam II" or Hunter Panels "H -Shield", any thickness. Base Sheet: — "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT" (self adhered). Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR" or "POLYFRESKO G SBS SA P FR" (self adhered). 26. Deck: NC Incline: 1/2 Base Sheet: — Type G1 or G2, mechanically fastened. Membrane: — "POLYFLEX G", "XtraFlex APP G HP TOR", "Xtraflex APP G" or "POLYBOND G", heat fused. 0000 27. Deck: NC Incline: 3 • ' • • 0000 ••••�• Membrane: — "POLYFLD( SA P FR", "POLYFRESKO G APP SA P FR", "POLYFRESKO G SBS SA P FR"or "ELAftFLE!i( SA P F'Ifleelfi • adhered). 6060•• '• ""'• • ••••s• • • • 0000•• 28. Deck. NC Incline: 1 0000 • • • • • • • 0 • • • • • • • • • • Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — "ELASTOFLEX SA V", "ELASTOFLEX SA V PLUS", "Xtraflex SBS Base SA" or "EL1k""-O( SA VtAsE'lwr, 0000• self -adhered or "ELASTOBASE", "XtraFlex SBS GLASS Base" (poly/sand), mechanically fastened. •• •• 0000 ""0' Membrane: — "POLYFLD( SA P", "Xtraflex APP G SA" "XtraFlex Kool APP G SA", or "POLYFRESKO G APP SW*"sa f•adhered or YPOLYFLEX 00 FG FR", heat fused. • ' • • • • *see** 0000•• • • 29. Deck: C-15/32 Incline: 1/2 ••• • 0000•• •• 0 0000 • • • Insulation: — Polyisocyanurate (2 In. min), glass fiber (15/16 in. min), periite/polyisocyanurate composite, perlite/urethanlCaAlpsite (2 In. min). Barrier Board: —1/4 In. (min) G -P Gypsum DensDeck®, mechanically fastened, with 6 in. offset to plywood joints. Base Sheet: — "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLB( P -C" (heat fused or mechanically fastened). Membrane: — "ELASTOFLD( S6 G", "ELASTOFLEX S6 G -C" or "POLYFRESKO G SBS', (heat fused). 30. Deck- NC Incline: 1/2 Insulation (Optional) — Atlas Roofing "ACFoam III" or "ACFoam II", any thickness. Base Sheet: — "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: - "POLYKOOL SA" or "XtraKooi APP S SA", (self adhered). 5 of 10 3/26/2014 8:54 AM