RF-14-1646Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-222240
Scheduled Inspection Date: October 29, 2014
Inspector: Rodriguez, Jorge
Owner: HUMBLES, ALISON
Job Address: 300 NW 112 Terrace
Miami Shores, FL 33168-3300
Project: <NONE>
Permit Number: RF -7-14-1646
Permit Type: Roof
Inspection Type: Final Roof
Work Classification: Tile
Phone Number (617)872-6367
Parcel Number 1121360010260
Contractor: ISAACS ROOFING & INSULATION CORP Phone: (305)234-5234
rsunaing uepartment comments
RE ROOF TILE TO TILE AND FLAT TO FLAT Infractio Passed Comments
INSPECTOR COMMENTS False
Inspector Comments
Passed CREATED AS REINSPECTION FOR INSP-222186. CREATED AS
REINSPECTION FOR INSP-216834. Need to cut out excess cap sheet from
roofs edge
Missing renailing affidavit
Failed
Correction ❑
Needed
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
October 28, 2014 For Inspections please call: (305)762-4949 Page 25 of 46
RE: Permit #
Miami Shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Falx: (305) 756.8972
DATE: /0 z a a l
INSPECTION AFFIDAVIT
licensed as a (n) Contractor / Engineer / Architect,
(Print name and circle License Type) FS 468 Building Inspector
License #: C(-., 13 a. 7*1
On or about 1L? 7 -)2 ojfZ , g 0 /WL , I did personally inspect the roof deck nailing and
(Date & time)
Secondary water barrier work at
(Complete Job Site Address)
Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit
Man al (eased on 553.844 F.S)
Signature
State of Florida
County of Dade:
The undersigned, being the first duly swom, deposes and says that he/she is the contractor for the above property
menbor.od.
Swom to and subscribed before me this
Notary Public, Sate of Florida at
*General, Building, Residential, or Roofing Contractors or
permit # and address # dearly shown marked on the dec
Revised on 5/2112009
%
ALEJANDRA 8RIT0
-Ngj r Public • State of Florida
My Comm. Expires Jun 10. 2018
Commission # FF 101837
individual certified under 468 F.S. to make such an inspection. Include photographs of each plane of the roof with
each inspection
F.I.E.
FLORIDA INTERNATIONAL ENGINEERING
&TESTING LAB
INSIGHT•INNOVATION•INTEGRATION
Owner's Narr
Job Address:
Roofing Cont
Permit Numt
Florida International Engineering and Testing Lab LLC
16701 SW 117 Avenue, Miami, FL 33177
Telephone: (305) 378 -1991 -Fax: (305) 378-1997
Miami -Dade Lab Certification # 07 -0612.11 -State of Florida ca #27273
Approximate Roof Height: Q ® feet
Type of Access to Roof: Ladder
Slope: �� Approximate Square Footage: ?.I to 00 ft2
OtherRequired Testin F rce��:����° 35 lbs. Testing Equipment: F.G.E. 10 x S , im o Instrument
Date Installed: i ®q 1"R-0 ! Date of Inspection: D
--------------------- ----- _
-------------------------
�E' - TEST RESULTS
P= PASS, F= FAIL
Test
Location
P or F Test
Location
P or F Test
Location
P or F Test
Location
P or F Test Por F
Location
1
Vk421
P,�41
61
81
2
22
42
62
82
3
23
43
63
83
4
24
44
64 1
84
5
25
45
65
85
6
26
46
66
86
7
27
47
67
87
8
28
48
68
88
9
29
49
69
89
10
30
50 1
70
90
11
1 31
51
71
91
12
32
52
72
92
13
33
53
73
93
14
34
54
74
94
15
35
55
75
95
16
36
56
76 1
96
17 1
37
57
77
97
18
38
58
78
98
19
39
59
79
99
20
40
60
80
1 00
----------------------- ---------------------------------------------------------------------------------------------
IN ACCORDANCE WITH THE CRITERIA OF PROTOCOL TAS 106, THIS ROOF ASSEMBLY HAS PASSED THE STATIC UPLIFT QUALITY CONTROL TEST.
ADDITIONAL TEST INFORMATION
Perimeter Width: , ft
Area
Units or ft2
No. of Tests
Perimeter
® 0 �C'
Field
®®
Corners
61
Hips & Ridges
�®
RESP E�6�kLYt�SWk�,1 ED BY:
No 63107
StAe,otQ . 7
vlit', IQ rs gds a -' b%%%"
FLORIDA INTERNATIONAL ENGINEERING & TESTING LAB, LLC
Miami- Dade Lab Certification # 07-0612.11
Job Address:
Contractor:
e
Other:
Sketch of Roof
Notes
Miami Shores Village
Building Department
10050 N.E.2nd Avenue, Miami Shores, Florida 33138
Tel: (305) 795.2204 Fax: (305) 756.8972
INSPECTION'S PHONE NUMBER: (305) 762.4949
BUILDING
PERMIT APPLICATION
Permit Type: BUILDING
JOB ADDRESS: a ®® V11111) k 12 ' r2
JUL 20 2014
BY:
FBC 2010
Permit No — 14 "0
Master Permit No.
ROOFING
City: Miami Shores County: Miami Dade Zip:
Folio/Parcel#:
Is the Building Historically Designated: Yes NO i-_" Flood Zone:
OWNER: Name (Fee Simple Titleholder):_ LAEhes Phonek
Address: tJ "� VkTA°-•
City: State: _-F - Zip:
Tenant/Lessee Name: Phone#:
Email:
CONTRACTOR: Company Name: ►!'-
Address: ('� 2:7
City:/� -1
Qualifier Name: 41 4--t,�
State Certification or Registration #: C �t 3y� S CO Certificate of Competency #:
Contact Phone#: Email Address:
DESIGNER: Architect/Engineer: Phone#:
Value of Work for this Permit: $T'"Z, Square/Linear Footage of Work:
Type of Work: ❑Addition ❑Alteration ❑New \ eplace ❑Demolition
Description of Work: 74& � 9_cD f t i LC 7, 'CLUE f l'f1 nea -641,
Color thru tile:
Submittal Fee $ ��� �� Permit Fee $ CCF $ CO/CC $
Scanning Fee $ Radon Fee $ DBPR $ Bond $
Notary $ Training/Education Fee $ Technology Fee $
Double Fee $ Structural Review $
TOTAL FEE NOW DUE $92C) . n
q o co
Bonding Company's Name (if applicable)
Bonding Company's Address
City
State
Mortgage Lender's Name (if applicable)
Mortgage Lender's Address
City State
Zip
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS,
FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC.....
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING
YOUR NOTICE OF COMMENCEMENT."
Notice to Applicant: As o condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must
promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person
whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site
for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the
inspection will not be approved and a reinspection fee will be charged.
Signature -&&,, Ka4!9"
OWNER or AGENT
The foregoing instrument was acknowledged before a this
2, , day of U- 20 by
who is personally known to
me or who has produced
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Signature
CONTRACTOR
The foregoing instrument was acknowledged before me this
ZAr, day of 20 . by
aW-=� ,-who is personally known to
as me or who has produced
as
identification and who did take an oath.
NOTARY PUBLIC:
Sign:
Print:
Seal: J"Y 11" Gilda Pereda Seal:
�rA...a .
a `c+,'_COMMISSICd#EE144691
1$ EXPIRES: DEC. 07, 2015
aw�s�*xsrx��`a+sVA! _ `G�p era+r*_xxa+ea+���sx*****�►���
APPROVED BY Plans Examiner
Structural Review
(Rev1sed02/24J2014)
ELIZABETH J HUBBARD
MY COMMISSION b EELS5795
EXPIRES December 03, 2010
Zoning
Clerk
Miami shores Village
Building Department
10050 N.E.2nd Avenue
Miami Shores, Florida 33138
Tel: (305) 795.2204
Fax: (305) 756.8972
OWNERS'S AFFIDAVIT OF EXEMPTION
ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE -
BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES
PERSUANT TO SECTION 553.844 F.S.
To: Miami Shores Village Building Department Date:
10050 NE 2rw Ave
Miami Shores, FI 33138 d
Re: Owner's Name:
Property Address: C> LL2t P-
Roofing Permit Number.
Dear Building Official:
I Ak-& sLJ certify that I am not required to retrofit the roof to wall connections of my
building because:
®'rhe just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad
valorem taxation.
o The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions
of 1994 edition of the South Florida Building Code (1994 SFBC)
hh'. 14"4&j '5V') 'u VAA is L6f
Signature
State of Florida
County of Dade
Print Name
The undersigned, being the first duly sworn, deposes and says that he/she is the owner for Pe above property mentioned.
��� PG �.
Sworn to and subscribed before me this a"' day of �+� a 8�,, Gilda Per144
�:COMMISSICif#EE144691
re, rgorc-1� v ,��,,�.��„� .•op+°;; EXPIRES: DEC. 07, 2015
M'WW.AARONNOTARY.Com
Notary Public, Sate of Florida at Large
When the p9vah a5m of ere structure for purpose of ad vabr n Wxdw is "to a w than $3o0.=M. and the buift was nW consW0d v0 FIX nor a 1994
SFBC. Then you mst protide a WHing appr+cdm from a General Contr ft for fhe Roof to WPI wmwcft Hurricane ft9don.
Revised on 5/21/2409
Section A
MI1AMI'DADE Miami -Dade County Building Department Electronic Application
® High Velocity Hurricane Zone Roofing Permit Application Form
"Delivering Excellence Every Day"
Section A (General Information)
Master Permit No: Process No:
Contractor's Name: I Isaacs Roofi
Job Address: 1 300 NW 112Tr.
R1 Low Slope
Roof Category
❑ Mechanically Fastened Tile
❑ Mortar/AdhesivejSet Tile
❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes
❑ Sprayed Polyurethane Foam ❑ Other: _
Roof Type
❑ New Roof ❑✓ Re -Roofing ❑ Recovering ❑ Repair ❑ Maintenance
Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No If yes, what type?; 4• Naturat.O.LPGX ......
.. . .
Roof System Information ••• ••
...... •
0*6000
Low slope roof area (ft. 300 Steep Sloped area (ft.2) 2000 Total (ft.2)2300" • •
Section B (Roof Plan) • • • • % '..' .....
Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and.oeierli8w drah-C Jgdlude • • • • •
ons of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets, • •
• • •
ier Width (a'): Corner Size (a' x a'): ; 00000
•
••o*
••••
FE1
W CD
D C
in m
z
®
®
N
Z
5
'0
a --i
O
C o
rn
®
<
Z 9
C
�
C
Fn m
z -+
cn
0
CD
0
a s
<
M
o
Oa
C: m
4 m
O
Z
G
f
M
Tile Roof System
O
iAMNf Miami -Dade County Building & Neighborhood Compliance Department
O HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day" Section D Tile Roof System
Roof System Manufacturer: Eagle
Notice of Acceptance Number (NOA): 12-0430.04
Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations):
P1: 145.1 1 P2: 78.6 P3: 116.2
Maximum Design Wind Pressures, (From the NOA Specific system): 4 psf
Fill in the speck roof assembly components. If a component is not required, insert not applicable (n/a) in the text box.
Roof Slope: 3 5 _ 11/12"
Roof Mean Height: 10 ft.
Method of Tile Attachment:
--Adhesive, 2 Small Paddy Tile Bond --
Alternate Method of Tile Attachment per NOA:
n/a
Drip Edge Size & Gauge: 73" face 24 ga: -
Drip Edge Material Type: --Galvinized Metal --
Deck Type: 71" x 6" T & G--
Optional Insulation:
n/a
0000
0
Optional Nailable Substrat*: ""
000006
6 6
n/a 0000..
-
0000..
� •
• 6 g
666666
Optional Nailable SubstratO ct�ment -* • 6
' '
06000
n/a 6...66 ..
:0000.'
. 6.
•• 0000
0000..
666.66
•
Basesheet Type: : ' ;
•
30# '
.66666
0000
Fastener Type for Basesheet Attachment:
1 1/4" Ring shank nail & Tin caps
Tile Underlayment (Cap Sheet) Type:
TU Pius
Tile Underlayment Attachment Method:
Self adhered
Drip Edge Fastener Type: 1 1/4" Ring shank nail Tile Profile:
Bel Air Flat
Hook Strip/Cleat gauge or weight: --n/a
Section E
MIAMI'N Miami -Dade County Building & Neighborhood Compliance Department
° HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day"
Section E (Tile Calculations)
Method 1 "Moment Based Tile Calculations Per RAS 127"
For Moment based file systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are
greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable.
P 1: 45.1
X X.278
= 12.54 - Mg: 7.59 `
= Mr1: 4.95
s 131.3 1 NOA Mf
P 2: 78.6
X X.278
= 21.85 - Mg: 7.59 -
-
_ Mr2: 14.26
s 1.31.3 NOA Mf
P 3: 116.2
X X.278
= 32 30 - Mg:
7.59
= Mr3: 24.74
s 31.3 NOA Mf
Method 3 "Uplift Based Tile Calculations Per RAS 127"
Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr. If the P values are greater than or equal to the Fr values, for
:ac rea of the roof, then the file attachment method is acceptable.
P1: x , =
xw: _
- W.
=
• • •66
•
x cos 8: = Fr1: • 6. 5 A
•66
• •
.. ,._
x I: =
x w: _
- W:
=
x cos 6: = Fr2: << F
t�*IN16A
......P2:
:.•..:
• •
P3: X I: =
x w: _
- W:
=
• 0 . •
ee
x cos 6: = Fr3: • : ; • NQ;
• •
•
• • • • •
•• •• 6666
• .: • •
6666••
6666••
re to Obtain Information to complete tile calculations ; ••
•
'.
0
.6006.
Description
Symbol
Where to Find " 0 :066
0000
• •
Design Pressure
P1 or P2 or P3
Table NIRAS
127, or by an engineer analysis prepared, signed and sealed by a professional
engineer baspd
on ASCE 7.
Mean Roof Height
H
Job Site
Roof Slope
8
Job Site
Aerodynamic Multiplier
Product Approval (NOA)
Restoring Moment due to Gravity
Mg
INRoduct Approval (NOA)
Attachment Resistance
Mf
Produ pproval (NOA)
Required Moment Resistance
Mr
Calcu ed
Minimum Attachment Resistance
F
Product Approval A)
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval (NOA)
Tile Dimensions
I = length
w = width
Product Approval (NOA)
Section C
M1AMk Miami -Dade County Building & Neighborhood Compliance Department
g 12! HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day" Section C page (Low Slope Roof Systems)
Fill in the speciflc roof assembly components. if a component is not required, insert not applicable (n/a) in the text box.
ROOF SYSTEM MANUFACTURER: I Polyglass
Product Approval (NOA): 13-0514.10 System Type: I E (1)
Wind Uplift Pressures, From RAS 128 or Sealed Calculations:
(P1) Field: 142.81psf
(P2) Perimeters: 71 •T psf
(P3) Comers: 108 psf
Maximum Design Pressure From NOA: 52.5 psf
Roof Slope: _1/8 " : 12 Roof Mean Height: 20 ..__....... ft.
Parapet Walls: O No ❑ Yes Parapet wall Height: 0
Deck Type: —1" x 6" T & G—
Support Spacing: Na " o/c
Alternate Deck Type: n/a
Existing Roof:
Na
Fire Barrier:
Na
Vapor Barrer:
Na
Anchor Sheet:
75# & Elastobase
Anchor Sheet Fastener / Bonding Material:
1 1/4" ring shank nails
Insulation Base Layer Size & Thickness:
Na
Insulation Base Layer Fastener/ Bonding Material:
F
Insulation Top Layer Size & Thickness:
Na
Insulation Top Layer Fastener / Bonding Material:
n/a
Base Sheet(s) & No. of Ply(s):
1- Elastoflex SA V FR
Base Sheet Fastener / Bonding Material:
Self -Adhered
Ply Sheet(s) & No. of Ply(s):
Na
Ply Sheet Fastener/ Bonding Material:
n/a
Single Ply Manufacturer/ Type:
Na
Single Ply Sheet Width: " 1/2 Sheet Width: r7"
No. of Single Ply 1/2 sheets:
Single Ply Membrane Fastening / Bonding Material:
Na
S FASTENER SPACING FOR BASESHEET ATTACHMENT
❑ SINGLE PLY MEMBRANE ATTACHMENT
••.•
1. Field: 18 1" o/c @Laps & Erows 8 • " o/c ' • • • •
2. Perimeter. 6 " o/c @ Laps & 4 fAwB. 6 " o/c
3. Comer: ILJ" o/c @ Laps & LLJroyp. LU " o% .
NUMBER OF FASTENERS PER INSULA X"111OARD:: • •
.0000. ••
1. Field: 2. Perimeter: • 8. Comer.
•, • •
Insulation Fastener TYID 000000
•
� • •
Na .0600
WOOD NAILER TYPE AND SIZE: • • • sees
0000
Na
..._.-_.__...
Wood Nailer Fastener Type and Spacing:
Na
0000••
•
•
•
0000••
6.6••
0000•
0000••
•
0000••
EDGE & COPING METAL SIZES:
Edge Metal Material: -Galvanized Metal—
Edge Size: —3" face 26 ga.-
Hook Strip Size: PELECT EDGE METAL HOOK STRIP SIZE—
. _ ._.. _..... _..... .
Edge Metal Attachment:
Na
Coping Material: SELECT PARAPET WALL COPING MATERIAL—
Coping Size: —SELECT COPING METAL SIZE OR THICKNESS -
Hook Strip Size: SELECT COPING METAL HOOK STRIP SIZE—
Parapet Coping Metal Attachment:
n/a
Section C2
Ran
Miami-Dade County Building & Neighborhood Compliance Department
HVHZ Electronic Roof Permit Form
"Delivering Excellence Every Day"
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Terminations/Stripping/Flashing, Continuous Cleat, Cant Strip, Base
Flashing, Counterflashing, Coping, Etc.
Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material
Thickness, Fastener Type, Fastener Spacing
Or: Submit Manufacturers Details that Comply with RAS -111 and Chapter 15 HVHZ, FBC.
jPolyf lex SA P
file:NCl/Documents%20and%20Settings/sky/Desktop/root%20permit%20forms/Section%20C2d.htm9/5/2007 7:18:20 AM
•• •
00• 0
66000•
••
000000
•00••0600•
•
• • •
600•
• ••
•066•
•0060•
• ••
• •
•606•
•6 ••
•000
000000
•
• pti
• Y
•
+
Mean Roof Height •
•
0
••600•
• 0
•6000•
file:NCl/Documents%20and%20Settings/sky/Desktop/root%20permit%20forms/Section%20C2d.htm9/5/2007 7:18:20 AM
Owner's Notification Form HVHZ 2010
rourwyl-
"Delivering Excellence Every Day" SECTION 1524
HIGH VELOCITY HURRICANE ZONES— REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS
1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner
with the required roofing permit, and to explain to the owner the content of this section. The provisions of
Chapter 15 of the Florida Building Code, Building govern the minimum requirements and standards of the
industry for roofing system installations. Additionally, the following items should be addressed as part of the
agreement between the owner and the contractor. The owner's initial in the designated space indicates that the
item has been explained.
. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane
Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion
performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions.
Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed
as part of the agreement between the owner and the contractor.
2. Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be
renailed in accordance with the current provisions of Chapter 16 (High. Velocity Hurricane Zones) of the Florida
Building Code. (The roof deck is usually concealed prior to removing the existing roof system).
3. Common roofs: Common roofs are those which have no visible delineation between Upighboring
units (i.e. townhouses, condominiums, etc.). In buildings with common roofs, the rootng epntraclor-add/or ... • • •
owner should notify the occupants of adjacent units of roofing work to be performed. • • • • • • . .
6 •• 0000..
0.
4. Exposed ceilings: Exposed, open beam ceilings are where the underside 0oJ0•0tW roof decking cao0� g•,
viewed from below. The owner may wish to maintain the architectural appearance; tAerefdre, rcgb$gg•nail
00:000
'
penetrations of the underside of the decking may not be acceptable. The owner provid8.1...'tlf�. optip%of .0006
666.
000000
maintaining this appearance.
0000.. •
5. Ponding water: The current roof system and/or deck of the building may not drain lrall%nd may •' •
cause water to pond (accumulate) in low-lying areas of the roof. Ponding can bean &dicalion of slWturaf •••••
:
distress and may require the review of a professional structural engineer. Ponding may shorten 14 life
expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original
roofing system is removed. Ponding conditions should be corrected.
L�� —6. Overflow scuppers (wall outlets): It is required that rainwater flow off so that the roof is not
overloaded from a build up of water. Perimeter/edge walls or other roof extensions may block this discharge if
overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance
with the requirements of: Chapter 15 and 16 herein and the Florida Building Code, Plumbing.
entilation: Most roof structures should have some ability to vent natural airflow through the
interior of the structural assembly (the building itself). The existing amount of attic ventilation shall not be
reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate
the attic venting, venting shall not be required.
Owner's/Agent's Signature: Date:
Contractor's Signature: Permit Number:
71 Property Address:
Eagle Roofing Products LLC
1575 East C.R. 470
Sumterville, FL 33585
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle
Low Profile Concrete Tiles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
4444
TERMINATION of this NOA will occur after the expiration date or if there has been a revtslon ®r change m the
0000..
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an end9 seplept of any Mcrduct,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure iG pbuWly with apy sectiop
of this NOA shall be cause for termination and removal of NOA.0000 0 0
.0
400• . .0 00000
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flvdda,:and ftllpq by the a we
expiration date may be displayed in advertising literature. If any portion of the NOA is disolayhh, then it thhfl be doAA 0 4
in its entirety. :":0: 400
0 4 4 900400
440444
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturel or itis distrlbiltpi %and :O 0.4 0
shall be available for inspection at the job site at the request of the Building Official. 00:0
This revises NOA# 11-0321.02 and consists of pages 1 through 10.
The submitted documentation was reviewed by Alex Tigera.
APPROVED
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 1 of 10
S..awv M
"M ,
MIAM
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidaae. ov/oera
Eagle Roofing Products LLC
1575 East C.R. 470
Sumterville, FL 33585
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to
be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this
acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Bel Air, Bel Air Double Eagle, Ponderosa, Ponderosa Double Eagle, Golden Eagle
Low Profile Concrete Tiles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
4444
TERMINATION of this NOA will occur after the expiration date or if there has been a revtslon ®r change m the
0000..
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an end9 seplept of any Mcrduct,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure iG pbuWly with apy sectiop
of this NOA shall be cause for termination and removal of NOA.0000 0 0
.0
400• . .0 00000
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flvdda,:and ftllpq by the a we
expiration date may be displayed in advertising literature. If any portion of the NOA is disolayhh, then it thhfl be doAA 0 4
in its entirety. :":0: 400
0 4 4 900400
440444
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturel or itis distrlbiltpi %and :O 0.4 0
shall be available for inspection at the job site at the request of the Building Official. 00:0
This revises NOA# 11-0321.02 and consists of pages 1 through 10.
The submitted documentation was reviewed by Alex Tigera.
APPROVED
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 1 of 10
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE:
This approves a new roofing system using "Low Profile Concrete Tile" as manufactured by Eagle Roofing
Products LLC in Sumterville, FL and described in Section 2 of this Notice of Acceptance. For locations
where the pressure requirements, as determined by applicable Building Code does not exceed the design
pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4
herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION:
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Bel Air Concrete Tile
L = 17"
TAS 112
Flat profile concrete roof tile equipped with two
W = 12'/4"
nail holes. For adhesive set, direct deck or
Thickness ='/Z"
battened nail -on applications.
Bel Air Double Eagle
L = 17"
TAS 112
Flat profile concrete roof tile equipped with two
Concrete Tile
W = 12'/4"
nail holes. For adhesive set, direct deck or
Thickness ='/2"
battened nail -on applications.
Ponderosa Concrete Tile
L = 17"
TAS 112
Flat profile concrete roof tile with slate finish
W = 12'/4"
equipped with two nail holes. For adhesive set,
Thickness ='/2"
direct deck or battened nail -on applications.
Ponderosa Double Eagle
L = 17"
TAS 112
Flat profile concrete roof tile with shake finish
Concrete Tile
W = 12'/4"
equipped with two nail holes. For adhesive set,
Thickness ='/2"
direct deck or battened nail -on applications.
9999
Golden Eagle Concrete
L = 17"
TAS 112
Flat profile concrete rQgf tife brusjfX1744ish **0::*
Tile
W = 12'/4"
equipped with two n§U JVJ�s. For adhave sed••,:9
Thickness ='/Z"
direct deck or battened "on applications. .
.9000.
9999 ..
Trim Pieces
1= varies
TAS 112
Accessory trim, clay roof pieces for use at hips • • •
w = varies
•
rakes, ridges and valla . tgiinatigns, • • 0 • • • • •
varying thickness
Manufactured for eaW till profile. "" ""0
.0000. so
. . ..9..9
0000..
. 9 .0000.
90 . 0000 9
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 2 of 10
2.1 EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Revort
Date
PRI Asphalt Technologies
ERPF -001-02-01
TAS 112
Aug. 2006
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
TAS 102
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
TAS 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II
TAS 108 (Nail -On)
Redland Technologies
P0402
Withdrawal Resistance Testing of screw vs.
Sept. 1993
smooth shank nails
Redland Technologies
Letter Dated Aug. 1,
Wind Tunnel Testing
Aug. 1994
1994
TAS 108 (Nail -On)
Redland Technologies
P09647-01
Wind Tunnel Testing
Aug. 1994
TAS 108 (Mortar Set)
The Center for Applied
94-084
Static Uplift Testing
May 1994
Engineering, Inc.
TAS 101 (Mortar Set)
The Center for Applied
25-7094-(2, 5, & 8)
Static Uplift Testing
Oct. 1994
Engineering, Inc.
TAS 102
The Center for Applied
25-7183-(5 thru 6)
Static Uplift Testing
Feb. 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7214-(1, 5, & 8)
Static Uplift Testing
March, 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7487-2
Static Uplift Testing
Dec. 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7496-(1 & 4)
Static Uplift Testing
Dec. 1995
Engineering, Inc.
TAS 102
The Center for Applied
25-7804-6
Static Uplift Testing
• �� •1996
Engineering, Inc.
TAS 102
• • •
Celotex Corporation Testing
520109-1
Static Uplift Testing • • • ; • •
Dee ! 1998 .... `•
Service
520111-4
TAS 101 '•""
'
Celotex Corporation Testing
520191-1
Static Uplift Testing '....'
;Marogh 1999.....
Service
TAS 101 ......
.. ..:..'
Walker Engineering, Inc.
Calculations
. ..
Aerodynamic Multiplier'S.e0
. ......
. 0 2006 •
Walker Engineering, Inc.
Calculations
Restoring Moments Due to Gravity %
•
Se�p..� 006 • • • • •
.60
.. .
.
000*0*
.... .
0000
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 3 of 10
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required,
refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance
Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
4. INSTALLATION
4.1 Eagle Roofing Products LLC Bel Air, Bel Air Double Eagle, Ponderosa, Golden Eagle, Ponderosa Double Eagle
Flat Concrete Roof Tiles and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w)
Tile Profile
Weight -W (lbf)
Length -i (ft)
Width -w (ft)
Bel Air, Bel Air Double Eagle,
11.4
1.42
1.03
Ponderosa, Golden Eagle,
Ponderosa, Golden Eagle,
•..• ...
Ponderosa Double Eagle Flat
...... '.: ..
Tile
Table 2: Aerodynamic Multipliers - A (ft)
Tile Profile
A (ft)
A (fe)
Batten Application
Direct Deck AppQ2glion
Bel Air, Bel Air Double Eagle,
0.301
A.278 •....• ..
Ponderosa, Golden Eagle,
•..• ...
Ponderosa Double Eagle Flat Tile
...... '.: ..
000.0• •
0000 • •• 0000•
0000•• • •• 0000•
•• •• 0000 0000••
•
•••••• • •
• 0 • • 00.00•
0000••
• • • • •
• • • 0000••
0000
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 4 of 10
Table 3: Restoring Moments due to Gravity - M9 (ft-lbf)
Tile
311:12"
4":12"
5":12"
6":12"
Greater than
Profile
30.9
38.1
17.2
1-10d Smooth or Screw
Shank Nail
7':12"
Bel Air, Bel Air
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Double Eagle,
51.7
Deck
24.4
Deck
1-10d Smooth or Screw
Shank Nail Field Clip)
Deck
24.3
Deck
1-10d Smooth or Screw
Shank Nail Eave Clip)
Deck
Ponderosa,
7.48
7.71
7.37
7.59
7.22
7.44
7.05
7.27
6.86
7.07
Golden Eagle,
2-10d Ring Shank Nails 50.3 65.5 •..#$'3
1. Installation with a 4" tile headiap and fastemers are located a min. of 2'/" from Meati Of tile....
Ponderosa
Double Eagle
Flat Tile
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Bel Air, Bel
Air Double
Eagle,
Ponderosa,
Golden
2-10d Ring Shank Nails
30.9
38.1
17.2
1-10d Smooth or Screw
Shank Nail
7.3
9.8
4.9
2-10d Smooth or Screw
Shank Nails
14.0
18.8
7.4
Eagle,
Ponderosa
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
Double
Eagle Flat
Tile
1-10d Smooth or Screw
Shank Nail Field Clip)
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail Eave Clip)
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails 50.3 65.5 •..#$'3
1. Installation with a 4" tile headiap and fastemers are located a min. of 2'/" from Meati Of tile....
000.0•
'•:
0000••
•
0000
•• •
0000
• ••
0000••
• ••
•• ••
0000
0000••
•
0000••
•• •
0000
0000.
0000..
0000•
0000•
0000••
•
•
•
0000••
•0000•
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 5 of 10
Table 6: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Resistance
Bel Air, Bel Air Double Eagle,
Adhesive
31.3
Ponderosa, Golden Eagle, Ponderosa
Tile
Double Eagle Flat Tile
3 Large paddy placement of 45 grams
of Pol ProTm.
1 See manufactures component approval for installation requirements.
2 Flexible Products Company TileBond Average weight per patty 13.9 grams.
3MTM 2 -Component Foam Roof Tile Adhesive AH -160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
for Single Patty Adhesive Set Systems
Tile Profile
Tile Application Minimum Attachment
Profile
Resistance
Bel Air, Bel Air Double Eagle,
3M 2 -Component Foam Roof Tile Adhesive AH -160 118.9
Ponderosa, Golden Eagle,
3M 2 -Component Foam Roof Tile Adhesive AH -160 40.4
Ponderosa Double Eagle Flat
Tile
5 Tile-Tite Roof Tile Mortar.
3 Large paddy placement of 45 grams
of Pol ProTm.
4 Medium paddy placement of 24 grams of Pol Prol*m.
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
Tile
Tile
Attachment
Profile
Application
Resistance
Bel Air, Bel Air Double Eagle, Ponderosa, Golden
Mortar Set5
43.9
Eagle, Ponderosa Double Eagle Flat Tile
5 Tile-Tite Roof Tile Mortar.
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 6 of 10
. .
....
..•...
......
..
......
....
. ..
.....
• •
......
. ..
.....
.. ..
....
......
......
•
.
•
. .
. .
......
e •
•
• •
0000
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 6 of 10
5. LABELING :
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See
Detail Below), or following statement: "Miami -Dade County Product Control Approved".
EAG���
FLORIDA
BEL AIR, BEL AIR DOUBLE EAGLE, PONDEROSA, GOLDEN EAGLE, PONDEROSA DOUBLE EAGLE
CONCRETE ROOF TILE LABEL, SUMTERVILLE PLANT
(LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 this Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 7 of 10
. .
....
......
......
..
......
....
. ..
.....
......
. ..
.....
. .
.. ..
....
......
. .
.
......
._00"
.
......
0000
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 7 of 10
PROFILE DRAWING
BEL AIR
BEL AIR DOUBLE EAGLE
•
0000.•
0000.•
.• .•
....•.
0000
•
0000
• .
0000•.
.
0000
0000
0000••
•
•
0000.•
0000..
0000•
0000.
00•.00
•
•
•
•..•..
..••.•
NOA No.: 12-0430.04
MIAMNDADE COUNTY
gp.
E iration Date: 10/05/16
• � �
Approval Date: 08/02/12
Page 8 of 10
PONDEROSA
PONDEROSA DOUBLE EAGLE
0000••
•
0000••
0000
0000
0000••
0000••
0000
•
0000
•
0000••
0000
0000..
•
0000.•
0000.•
0000•
•
0000•
0000.•
•
0000..
0000..
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 9 of 10
GOLDEN EAGLE
END OF THIS ACCEPTANCE
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 10 of 10
00.0
0000
0000..
0000..
..
0000..
0000..
0000
•• •
• •
• •
• • •
0000
• ••
0000•
• -
••...•
• ••
0000•
•0 .0
0.•0
sees:*
•
••••.••
•
• •
• .0000••
0000.•
• . •
0000••
•• •
0000
• •
0000
NOA No.: 12-0430.04
Expiration Date: 10/05/16
Approval Date: 08/02/12
Page 10 of 10
MIAMI•DADE :, MIAMI-DADE COUNTY
® PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
3M Company
3M Center Building 0220-05-E-06
St. Paul, MN. 55144-1000
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: 3Mrm 2 -Component Foam Roof Tile Adhesive AH -160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or ahonge in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endcltserpeit of anllproduct, for • • • •
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to c8lhpl� with-stption of •,
this NOA shall be cause for termination and removal of NOA. """
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Flo lho-and fo�liowAd by thy: •
expiration date maybe displayed in advertising literature. If any portion of the NOA is dis�yg4.then it sh1V be dory%: . • •
.
in its entirety. 669000 . .•�• **see*
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and..%
shall be available for inspection at the job site at the request of the Building Official. • 00* •
.. . ....
This NOA revises NOA 12-0228.18 and consists of pages 1 through 11. s o %
The submitted documentation was reviewed by Juan E. Collao, R.A.
�aoE Courrrir NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as
described in Section 2 of this Notice of Acceptance. For the locations where the design pressure requirements, as
determined by applicable building code, does not exceed the design pressure values obtained by calculations in
compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles
system using 2 -Component Foam Roof Tile Adhesive AH -160. Where the attachment calculations are done as a
moment based system for single patty placement, and as an uplift based system for double patty systems
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test Product Description
Specifications
3MTM 2 -Component Foam N/A TAS 101 Two component polyurethane foam adhesive
Roof Tile Adhesive AH -
160
Foam Dispenser RTF 1000 N/A Dispensing Equipment
ProPack® 30 & 100 N/A Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list moment
resistance values with the use of 2 -Component Foam Roof Tile Adhesive AH -160 roof tile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
• • •"
•... 0000..
Prove
Test
Res>1 ' ' •
Density
ASTM D 1622
1.6 lbs./ft. •
Compressive Strength
ASTM D 1621
18 PSI Parallel to rise ""•' ;0000;
12 PSI Perpendicular to rise.•"'.
Tensile Strength
ASTM D 1623
0000 . .. 0000.
28 PSI Parallel to rise
Water Absorption
ASTM D 2127
0000.. . 0000.
0.08 Lbs./Ft2 • • •.. •
Moisture Vapor Transmission
ASTM E 96
as Ge 0900 sees..
3.1 Perm / Inch •
Dimensional Stability
ASTM D 2126
*60006 e •
+0.07% Volume Change @s40•F; 2 wegks Gees;.
+6.0% Volume Change @ 158°F.,100% VWi ffty, 2 . G
a . . 999009
weeks •• • •••• •
Closed Cell Content
ASTM D 2856
86% • • 9 •
Note: The physical properties listed
above are presented as typical average values as determined by
accepted ASTM test methods
and are subject to normal manufacturing variation.
NOA No.: 13-0502.02
MuaMaouu cout�rtr
. , .
�LIApproval
Expiration Date: 05/10/17
Date: 12/12/13
Page 2 of 11
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
#94-060
TAS 101
04/08/94
257818-1 PA
TAS 101
12/16/96
Trinity Engineering
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
ASTM D 1623
04/18/12
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
Miles Laboratories
NB -589-631
ASTM D 1623
02/01/94
Polymers Division
Ramtech Laboratories, Inc.
9637-92
ASTM E 108
04/30/93
Southwest Research Institute
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[1]
ASTM E 84
01/16/95
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS: 0""0
• 0000 0000•.
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assemely�foi fire ratiaj. • •'
2. All approved products listed herein shall be labeled and shall bear the imprint or identiiiaW&arking of Me 00 00"
manufacturer's name or logo and following statement: "Miami -Dade County Product Ctar%t oi•ApprovO or the :see*:
0 0 .• . . 0
Miami -Dade County Product Control Seal as shown below. •• • •
0000 . 0
. .
0000.. . .... 0000•000.
N1AM1•QADE COUNTY • • • • •
APPROVED•• 00 0000 •00000
3. 3M' 2 -Component Foam Roof Tile Adhesive AH -160 shall solely be used with flat, IQN! P tigh tile profiles. • 0
4. Minimum underlayment shall be in compliance with the Roofing Application Standarc RAS 120. ; • • • • Goose*
5. Roof Tile manufactures acquiring acceptance for the use of 3M' 2 -Component Foam Roof Tile Adhe:i-."AH- : • • •:
160 roof file adhesive with their tile assemblies shall test in accordance with TAS 101. 0000
6. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 3 of 11
INSTALLATION:
1. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 may be used with any roof tile assembly having a current
NOA that lists uplift resistance values with the use of 3MTm 2 -Component Foam Roof Tile Adhesive AH -160.
2. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied in compliance with the Component
Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive
attachment with the use of 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall provide sufficient
attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in
compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is
noted in the roof tile assembly NOA.
3. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 and its components shall be installed in accordance with
Roofing Application Standard RAS 120, and 3M Company's 3MTm 2 -Component Foam Roof Tile Adhesive AH -
160 Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M
Company shall supply a list of approved applicators to the authority having jurisdiction.
5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive.
The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0
(B).
6. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall be applied with Foam Dispenser RTF1000 or
ProPack® 30 & 100 dispensing equipment only.
7. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTm 2 -
Component Foam Roof Tile Adhesive AH -160 has been dispensed.
9. 3MTm 2 -Component Foam Roof Tile Adhesive AH -160 placement and minimum patty weight shall be in
accordance with the'Placement Details' herein. Each generic tile profile requires the specific placemeutipoted
herein. 0 0 0000
0000..
0000..
0000..
0000.
0000.
0000..
0000..
.0000.
NOA No.: 13-0502.02
MLAMM14DEC� Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 4 of 11
0000..
..
0000..
0000
•• 0
0 0
. . 0
0000
..
••
0 .
. .
00 00
0000
000000
0
0
0000..
00 0
0000
0000..
0000..
0000..
0000.
0000.
0000..
0000..
.0000.
NOA No.: 13-0502.02
MLAMM14DEC� Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
0000.6
0
Area
Weight
Eave Course - Flat, Low, High
Profiles
All Eave Course
17-23 sq. inches
45-65
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
:06:0:
head of tile 9-11 sq. inches at
. 0 . .
overlap
0000..
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
0000..
00 0 0000
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All 3M' 2 -Component Foam Roof Tile Adhesive AH -160 containers shall comply with the Standard Conditions listed
herein.
000•
. . 0000
0000.6
0
6
BUILDING PERMIT REQUIREMENTS: • • 0000
•
As required by the Building Official building in to t1ig 0iitallation lis
**"0
or applicable code order properly evaluate of
:
system.*00000
0000 :0
0000 . ..
0000.
0 0
00
0.000
0 0
00 00 0000
00.0.0
:06:0:
00
. 0 . .
000000
0000..
0 0
. 0
0000..
00 0 0000
0
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
(loll through plastic cement
(when required)
Paddy (Beneath Tile) I
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.. 0.0.0
. . 0000 0000..
.. 4 666 6
6 6
004.60
.. 0000..
666466
0000 ..
0000..
6666 . 66 64660
High Profile / Single Pan TWO,, • •; .00. 0.6.0
66 66 6666 666666
1. Starting at the eave coudt,*J�jty a minirflum 2" •
(50.8 mm) x 10" (254 mm) x 1'' (25.4 saw; foam
paddy onto the underlay6nt positioned as shown: 6 6 6 6:
00
under the pan portion of a tile clos ssl #60o0the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
Nall through plastic cement
When required)
Paddy (Beneath Tile)
Underlayment
1� 7in.2
`
Battens optional °
Ewe course
loin.
ai
Eave Closure
rough plastic cement
required)
Battens
(Beneath
Fascia
Closure
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
—23(148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm2) -12 (77.4 cm) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shwa? Wider the
pan portion of the tile closest to bur overl3cV of the 000%6
tile being set. Insure approyiijit& 17 (W • *m2) —
23 (18.4 cm2) square inch.gve contact wrath the:****:
underside of the tile. sees 0 0 :*so*:
saes s •• ss•.•
2. At the second course, apply aomirbimum 2 ' (W.8mm�.:.. •
x 7" (177.8 mm) x I" (25.44mr Foam pWanto the. - • a •
underlayment positioned at OM under thti pan • •
portion of the tile closest td the oderloc% pf Y%lr the • • • • • •
being set. : .10. 0;....;
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm) square inch adhesive
contact with the underside of the tile.
(Instructions continued on nextpage)
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm2) - 19 (122.6 cm) square inch adhesive
contact with the underside of the tile.
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 8 of 11
0000
. .
0000
0000..
.
•
0000..
08
0080.6
088800
0
0 0
0000
088888
. ..
00000
0::::0000o
..
00808
00 80
8008
80088
0
.8..8.
•
•
000006.
•
00 00..
0
0 0 8
88888.
00 a
8080
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 8 of 11
ADHESIVE PLACEMENT DETAIL # 3
no
PaftoetwemtfieQ
SWAM
t
• •
0000
000..0
......
..
......
Ion
x
0
0 0
0060
RaULOW Pftfft Tilt
APPROVED
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (10 1.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 int (109.7-148.4 cm) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course tile to be installed. Insure
approximately 8-9 int (51.6-58.1 cm2) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 9 of 11
• •
0000
000..0
......
..
......
000000
0
0 0
0060
..
000.0.
6 6
0.00
• ••
00.06
• 0
0 0 0
•• ••
0000
•0006•
•00.0•
•
• 0
• •
•
••000•
• •
0 • •
•000••
0
0 •
•• •
:*Go*: •
•000•
0000
•
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
4
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/a"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71 cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9(58.1 cm2) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
MIAM4DADE cOUMY NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 10 of 11
(when
tbetwmSeQ
enc
UOL
�Mlzt
to xbL
4
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/a"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cm2) - 11 (71 cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9(58.1 cm2) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
MIAM4DADE cOUMY NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 10 of 11
1? Place enough adhesive to achieve 65 to 701
In contact with the pan tile.
2) Tum covers upside down.Place adhesive in
to 1 in from outside edge of cover tile.
Then install the tile. Ensure 20 to'�%%
25 sq.IMcontact area,. .
Underlayment
I
Eave closure
(motar shown)
Fascia
ADHESIVE PLACEMENT DETAIL
TWO PIECE BARREL
0
point -up Mortar
on longitudinal
edges of the
Remove top portion of the cave course cover We. Abut to second course of
pan tiles. Ensure eave end of pan and cover tiles are flush at eave line.
Two Piece Barrel - High Profile rile
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under two adjacent pan tiles. Support eave tiles
from rocking until adhesive has a chance to cure.
2. Continue in same manner bringing two pan courses
up toward the ridge. Insure approximately 65
(419.4 cm) — 70 (451.6 cm) square inch adhesive
contact with the underside of the pan tile.
Turn covers upside down exposing the underside of
the tile. Apply a minimum 1" (25.4 mm) x 10" (254
mm) bead of adhesive directly on the inner edge of
each side of the cover tile. Leave approximately
3/4" (19 mm) to 1" (25.4 mm) from the outside
edge of the tile, inward, free of foam to allow for
expansion.
4. Turn cover tile over after foam is applied and place
onto pan tile course. Insure a minimum of 20 (129
cm2) - 25 (161.3 cm2) square inch contact area on
each side of the cover tile to the pan tile. Continue
in same manner. Trim away any cured N osed • • • • • •
foam adhesive. Pointingggf�lorggitudigil edges of so
the cover tiles are consid%W� gptional... •
9999.•
960.0. 9
5. When additional nailing ie.required, l: (5A.8 mm}"
x 4" (101.6 mm) nailers orthe'tie wise system .....
using galvanized, stainless•eAesgl, or cpppe elvire alter • • •
compatible nails may beiftsd& • • • • 600600
9999..
9999..
END OF THIS ACCEPTANCE •' g•"
NOA No.: 13-0502.02
Expiration Date: 05/10/17
Approval Date: 12/12/13
Page 11 of 11
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andifeVowing
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.-
0
erein•0 . 666
RENEWAL of this NOA shall be considered after a renewal application has been filed and't air1las been no L•hange 0.600 •
in the applicable building code negatively affecting the performance of this product. • 0 0 0 0 .. 6' :06600
000
6 6 6 •
TERMINATION of this NOA will occur after the expiration date or if there has been a rev
bs 6 o}' char a ip6 6he 0 0 6 6 •
p 1�� .• Y� .0000
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endor4ft0t of add PsQduct,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to.o�mfly with ar6y section 0
of this NOA shall be cause for termination and removal of NOA. 0000.. 0000 • •
000 • 6 6
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County•Fldtida, and6R3iloweA 0.06
by the expiration date may be displayed in advertising literature. If any portion of the NOA is dispfayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #11-1229.01 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 1 of 8
MIM
MIAMI -DADS COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGi1LATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.aw/economy
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state andifeVowing
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.-
0
erein•0 . 666
RENEWAL of this NOA shall be considered after a renewal application has been filed and't air1las been no L•hange 0.600 •
in the applicable building code negatively affecting the performance of this product. • 0 0 0 0 .. 6' :06600
000
6 6 6 •
TERMINATION of this NOA will occur after the expiration date or if there has been a rev
bs 6 o}' char a ip6 6he 0 0 6 6 •
p 1�� .• Y� .0000
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endor4ft0t of add PsQduct,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to.o�mfly with ar6y section 0
of this NOA shall be cause for termination and removal of NOA. 0000.. 0000 • •
000 • 6 6
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County•Fldtida, and6R3iloweA 0.06
by the expiration date may be displayed in advertising literature. If any portion of the NOA is dispfayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This revises NOA #11-1229.01 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Category: Underlayment
Material: SBS, APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 2 of 8
Test
Product
Product
Dimensions
Specification
Description
Polystick MTS
Roll:
TAS 103
A homogeneous, rubberized asphalt
underlayment
65'8" x 3'33/8"
waterproofing membrane, glass fiber reinforced
Manufacturing Location
60 mils thick
with polyolefinic film on the upper surface for
#2
use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
Polystick IR -Xe
Roll:
TAS 103 and
A fine granular/sand top surface self -adhering,
underlayment
65' x 3'33/8"
ASTM D 1970
APP polymer modified, fiberglass reinforced,
Manufacturing Location
Or 65' x 3'
bituminous sheet material for use as an
#1 & #2
60 mils thick
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
Polystick TU
Roll:
TAS 103 and
A heavy granuled surface self adhering, APP
underlayment
32'10" x 3133/$"
ASTM D 1970
polymer modified, fiberglass or polyester
Manufacturing Location
100 mils thick
reinforced, bituminous sheet material for use as
#1 & #2
an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus
Roll:
TAS 103 and
A rubberized asphalt self -adhering, glq$;
underlayment
65'x 3'33/8"
ASTM D 1970
fiber/polyester reinforced waterproof. • ......
(Surface Printing)
80 mils thick
membrane. Designed as acAeM rooiiag and roof
Manufacturing Location
the underlayment. • • • • • • • • 000000
#1 & #2
•••::*0. :
. .
Polystick TU P
Roll:
TAS 103 and
.... . .. .....
A rubberized asphalt wat pswfing tnerabrane, ..:..'
underlayment
32'l 0" x 3'33/8"
ASTM D 1970
glass-fiber/polyester reir4o'oed, wit$ 4L;ranular ......
Manufacturing Location
130 mils thick
surface designed for uslesgtle roof • • o
#2
underlayment. 669606
0
00.
Polystick Tile Pro
Roll:
TAS 103 and
A rubberized asphalt self -adhering, gLis-
Manufacturing Location
61' x 3933/8"
ASTM D 1970
fiber/polyester reinforced waterproofing
#2
60 mils thick
membrane. Designed as a metal roofing and roof
tile underlayment.
Polystick Dual Pro
Roll:
TAS 103 and
A rubberized asphalt self -adhering, glass -
Manufacturing Location
6 P x 3'V/8"
ASTM D 1970
fiber/polyester reinforced waterproofing
#2
60 mils thick
membrane. Designed as a metal roofing and
roof tile underlayment.
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 2 of 8
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick TU Max Roll: TAS 103 and A rubberized asphalt self -adhering, polyester
Manufacturing Location 65'8" x 3'3-3/8" ASTM D 1970 reinforced waterproofing membrane. Designed
#2 60 mils thick as a a roof tile underlayment.
MANUFACTURING PLANTS:
1.Hazelton, PA
2.Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Report
Date
Exterior Research & Design, LLC
11756.04.01-1
TAS 103
04/27/01
11756.08.01-1
ASTM D 1970
08/14/01
02202.08.05
TAS 103
08/29/05
Trinity I ERD
P5110.08.07
TAS 103
08/29/07
P10870.09.08 -R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P33370.04.11
ASTM D 1623
04/26/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
P37300.10.11
TAS 110/ASTM D4798 & D1970
10/19/11
P40390.08.12-1
TAS 103 & TAS 110
08/06/12
P40390.08.12-2
ASTM D 1623
08/07/12
P40390.10.12
ASTM D 1970
10/03/12
PRI Asphalt Technologies
PRI01 I I I
ASTM D 4977
®4/'0.8*J82
PUSA-005-02-01
ASTM D 4977 '.. •
Ql/.31/02
PUSA-018-02-01
ASTM D 2523 ......
07/1'4103
PUSA-035-02-01
TAS 103 • • • % • •
09/39/06
PUSA-033-02-01
ASTM D 1970 . • • • • .
0 /.l YQ6
PUSA-055-02-02
TAS 103 ""
12/14/07
PUSA-083-02-01
TAS 103
06/.3'/08
PUSA-089-02-01
TAS 103/ASTM D4798 & V15r
01%r;/09
Momentum Technologies, Inc.
JX20H7A
•
TAS 103/ASTM D4798 & f 155 ;
Q4/OV08
RX14E8A
TAS 103/ASTM D4798 & G155.
:??"/179
DX2313813
TAS 103/ASTM D4798 & NA :
021&40
DX231)8A
TAS 103/ASTM D4798 & G155
601,8/10
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Base Sheet: One or more plies of ASTM D 226 Type H or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self -adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. . All side laps shall be a minimum of 3-1/2" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 4 of 8
0000
......
000000
.
.
00. 00..
0000
..
0000
. ..
0000.
0000..
. ..
0000.
. .
. . 0
.. ..
....
0000..
.
......
so
. .
. .
0000..
......
o
. .
.0000.
.. 0
0000
. .
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 4 of 8
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, Tile Pro and Dual Pro may be used in asphaltic shingles, wood shakes and shingles,
non-structural metal roofing, roof tile systems and quarry slate roof assemblies. Polystick IR -Xe, TU, and TU
P may be used in all the previous assemblies listed except metal roofing. Polystick TU Max may be used in
roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations (days)
MTS IR -Xe TU TU Plus TU P Tile Pro Dual Pro TU Max
Winter Haven, FL. 180 180 180 180 180 180 180 90
Hazelton, PA. N/A 30 30 180 N/A N/A N/A N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9N-3 of the Florida Administrative Code.
8. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU, TU Plus, Tile Pro and TU Max may be used in both
adhesive set and mechanically fastened roof tile applications. Polystick IR -Xe, and Dual Pro are limited to
mechanically fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens
roof tile applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shjLtlelse4s
follows: (See Table Below)
.000..
.000.0
Tile Profile
Polystick MTS
Polystick IR -Xe
Polystick TU, +W: PolystlWFU
Plus, TU P, Tllle . Mfx
Pro 0000 :'. '.
Flat Tile
Prohibited without
5:12
No limitation... No limittion
battens•
.. 0000
Profiled Tile
Prohibited without
Prohibited
No limitation' •; No limitation
battens
a0 0
I
I ... -
000000
0000
0000.
.000.0
..0000
The above slope limitations can be exceeded only by using battens and counter battens in accordanle vAth tha • • • •
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements' •EAttens
are required for both loading and installation of tiles at all times.
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
m
CL
0
N
r
i0
Roofing Tiles
(6 Max Per Stack)
12
s
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and
Tile Pro may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR -Xe,
TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro as a component part of an assembly in the Notice of
Acceptance. If Polystick MTS, IR -Xe, TU, TU Plus, TU P, TU Max, Dual Pro and Tile Pro is not listed, a
request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control
Department for approval provided that appropriate documentation is provided to detail compatibility of the
products, wind uplift resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's ngm dor logo,
city and state of manufacturing facility and the following statement: "Miami-Dadg CoVnty PrOdUrt,Eontroj,,,,,
Approved" or the Miami -Dade County Product Control Seal as shown below. '..' 6.6 6
6..0.. .. 0606.6
MIAMHMDE COUPiTY •
,...• 666660
6666..
6000 .0 6 6 6
. .
6666 . .. .6666
BUILDING PERMIT REQUIREMENTS: . 6.6.6 • • • , •; 6 6
Application for building permit shall be accompanied by copies of the following: •. .. .0.0 ..
6.6.6. • •
1. This Notice of Acceptance. : 0 : + 6 6 ..6:.
0000++
2. Any other documents required by the Building Official or applicable building code in a idertaproperly: *Goo aluate • • • 6
the installation of this materials. 66;6
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 6 of 8
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, applied in between the application of the lap. The use of mastic
between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of 7"/12" or greater. It is suggested that on pitch/slopes in excess of 6'/4"/12", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement to the area in need of repair, followed by a patch of the Polystick material of like kind s1y11181V set
and hand rolled in place over the area needing such repair. Patching membrane shal:bee minimuiWdf6 "'•:'
inches in either direction. The repair should be installed in such a way so that water will run para%el•toor •.
•00.00 •• •••s••
over the top of all laps of the patch. 00000*
•
10. All self -adhered membranes must be rolled to ensure full contact with approved subsTMN Polygl%ss• • •
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrWe *Hand rbllef?are
. ... .
acceptable for rolling of patches or small areas of the roof. Brooming may be used w .s.lope p X .....
001 its *of*:*
rolling. 0000•• •
11. All approved substrates should be dry, clean and properly prepared, before any application of Poet t • • • • % •
membranes commences. An approved substrate technical bulletin can be famished.1ipciftequesf It is ;. • • •;
recommended to refer to applicable building codes prior to installation to verify accetlablt substrata • • •
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and *09
PolyProtector UDL can be furnished upon request by our Technical Services Department by calling 1 (800)
894-4563.
NOA No.: 12-0713.02
Expiration Date: 09/13/16
Approval Date: 02/14/13
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
0000
. .
. . ....
006..0
0.:
0000..
0000..
0000.. 0
0
0000..
00 0 0 .. 0
, ..
0000 . ...
00000
0000.. . .0
0000.
. .. .
,0 0. 0000
0000..
9
0000..
. . . ,
6990.0
0000..
9
.
..
0000..
.0 9 .009
. 0
0000
CMt•OU1DE=FM NOA No.: 12-0713.02
� Expiration Date: 09/13/16
M.
Approval Date: 02/14/13
Page 8 of 8
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks • • • • • • • • • ° • •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,•vity,eAate and fol0wing • • • • % •
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein' • • ° • • ; ° ° ° °;
• •
RENEWAL of this NOA shall be considered after a renewal a • • ° • ben o
• •chane • • • •
application has been filed and.has >r nL. g ..:..'
in the applicable building code negatively affecting the performance of this product. •.:..' ......
TERMINATION of this NOA will occur after the expiration date or if there has been a reAsion Or chat1gAV le • • • • •
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsetaient of any product, :....:
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to cote ply with a0 y section •
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 12-0818.07 and consists of pages 1 through 26.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 1 of 26
MIAM0MIAMI-DADE
COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
11805 SW 26 Street, Room 208
BOARD AND CODE ADMIMSTRATION DIVISION
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA)
www.miamidade.eov/economv
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Self -Adhered Roof System over Wood Decks • • • • • • • • • ° • •
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,•vity,eAate and fol0wing • • • • % •
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein' • • ° • • ; ° ° ° °;
• •
RENEWAL of this NOA shall be considered after a renewal a • • ° • ben o
• •chane • • • •
application has been filed and.has >r nL. g ..:..'
in the applicable building code negatively affecting the performance of this product. •.:..' ......
TERMINATION of this NOA will occur after the expiration date or if there has been a reAsion Or chat1gAV le • • • • •
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsetaient of any product, :....:
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to cote ply with a0 y section •
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 12-0818.07 and consists of pages 1 through 26.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 1 of 26
ROOFING ASSEMBLY APPROVAL
Cateifory' Roofing
Sub-Catellorv: Modified Bitumen
Materials SBS/APP/TPO
Deck Tybe• Wood
Maximum Design Pressure -112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test Product
Product Dimensions Specification Description
Elastobase 65' 2" x 3' 3-3/8" ASTM D 6163, SBS modified asphalt coated fiberglass reinforced
Type I base sheet.
Elastobase P 5' 2" x 3' 3-3/8" ASTM D 6164, SBS modified asphalt coated polyester reinforced base
Type I sheet.
Elastoflex SA V FR 32' 6" x 3' 3-3/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified
(1.5 -mm) Type I bitumen membrane with a self -adhering back face and
a smooth top surface.
Elastoflex SA V 32' 6" x 3' 3-3/8" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS modified
PLUS FR Type I bitumen membrane with a self -adhering back face and
a smooth top surface.
Elastoflex SA V (1.5- 32' 6" x 3' 33/g" ASTM D 6163, Self -adhered, fiberglass reinforced, SBS wpjified
mm)
Type I
bitumen membrane with a self-adhering%aekface and.....
a smooth top surface. • • • • • •
Elastoflex SA V
32'6"x3'3_3 /8" ASTM D 6163
fiber
Self -adhered lass rei• or.gc SBS modified •
g � .
PLUS
Type I
bitumen membrane with a sqj f dohering,back face ano• • • •;
a smooth top surface. '90000 a : *00* ..•••
Elastoflex SA P FR
32' 6" x 3' 3-3/8" ASTM D 6164,
Self -adhered, polyester reirfftddd3 SBS 3nodiFied 0000'
Type I
bitumen membrane with a self-aahering back face ana9. •: •
a granule top surface.•
Elastoflex SA P
32' 6" x 3' 3-3/8" ASTM D 6164,
• • • • 090.00
Self -adhered, fiberglass rei;forye� SBS•modified
Type I
• �;
bitumen membrane with a sdlt'-adhering bapitOfte and •
a granule top surface. 0000
Polyflex SA P
32' 6" x 3' 33/8" ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyflex SA P FR 32' 6" x 3' 33/8" ASTM D 6222, Self -adhered, polyester reinforced, APP modified
Type I bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko SBS SAP 32' 6" x 3' 33/8" ASTM D 6164, Self -adhered, fiberglass reinforced, SBS modified
Type I bitumen membrane with a self -adhering back face and
a granule top surface.
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 2 of 26
Polyfresko SBS SAP
32' 6" x 3' 33/8"
ASTM D 6164,
Self -adhered, fiberglass reinforced, SBS modified
FR
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko APP SAP
32' 6" x 3' 33/8"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a granule top surface.
Polyfresko APP SAP
32' 6" x 3' 33/8"
ASTM D 6222,
Self -adhered, polyester reinforced, APP modified
FR
Type I
bitumen membrane with a self -adhering back face and
a granule top surface
PolyKool
32' 10" x 3' 33/8"
ASTM D6222
Self -adhered, polyester reinforced, APP modified
Type I
bitumen membrane with a self -adhering back face and
a white film laminate on the top surface.
PG-' 25 Cold Process
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered cold process adhesive for use with roll or
Adhesive
tube
Type III
BUR roofing.
PG 100 Asphalt Primer
1, 3, 5, 50, 55 gal,
ASTM D41
A penetrating solution of solvent and a blend of
tube or 17 oz. spray
selected asphalts used to promote adhesion.
can
PG350 Mod Bit
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
Adhesive
tube
Type III
modified bitumen membranes.
PG400 Plastic Roof
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use in
Cement
tube
ASTM D3409
dry or damp conditions.
PG425 Wet/Dry Roof
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use in
Cement
tube
ASTM D3409
dry or damp conditions.
PG450 Flashing
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flasjiing celt8e44.* • • • • • • •
Cement
tube
. . '
0000 :
PG500 MB Flashing
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberizefl'f;Vhing cement far use
Cement
tube
with modified bitumen mefn'branes. :....:
Polyplus 35 Premium
1, 3, 5, 50, 55 gal. or
ASTM D3019
.... ..
A fibered rubberized adhesiveclesigne&or4se with ......
Mod Bit Adhesive
tube
Type III
modified bitumen membrantp •; •••••
Polyplus 45 Premium
1 3 5 50 55 al. or
ASTM D4586
0090
A thick,fibered rubberize • * • n ceme • • • • �'
Flashing Cement
tube'
• •
. . . . ......
Polyplus 50 Premium
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberizeV flas%ng cetiient for use ;....;
MB Flashing Cement
tube
with modified bitumen memTrangs. ."' '
Polyplus 55 Premium
1, 3, 5, 50, 55 gal. or
ASTM D4586
....
A mastic compound for use as a roof flashing
Modified Flashing
tube
adhesive.
Cement
NOA No.: 13-0514,10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 3 of 26
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description
Polytherm-H
Polyisocyanurate foam insulation
Polytherm
Polyisocyanurate foam insulation
Polytherm Composite
Polyisocyanurate/perlite composite insulation.
ACFoam-II
Polyisocyanurate foam insulation
ACFoam-III
Polyisocyanurate foam insulation
High Density Wood Fiberboard
Wood fiber insulation board
Perlite Insulation
Perlite insulation board
Type X Gypsum
Fire resistant rated gypsum.
DensDeck, DensDeck Prime
Gypsum insulation board
H -Shield
Polyisocyanurate foam insulation
H -Shield CG
Polyisocyanurate/perlite composite insulation
ENRGY-3, JM ISO 3
Fesco Board
Multi -Max FA -3
SECUROCK Gypsum -Fiber Roof Board
Polyisocyanurate foam insulation
Expanded mineral fiber
Polyisocyanurate foam insulation
Fiber reinforced coverboard
Manufacturer
(With Current NOA)
Polyglass USA, Inc.
Polyglass USA, Inc.
Polyglass USA, Inc.
Atlas Roofing Corp
Atlas Roofing Corp
Generic
Generic
Generic
Georgia-Pacific
Hunter Panels, LLC
Hunter Panels, LLC
Johns Manville Corp.
Johns Manville Corp.
Rmax Opera 4k" LLC.
. . .. . ...
• United States (!yUsum ...•
9 • • • • *.CorpOratll7p: 6669:9
•
040••9 • • •
•94.0•
*006 0
4.4• • •• • 4
•0000
•4994• • •• 04440
• 0 9 0 4
•• •0 04•6 •4.44•
•
•04.99 • on
• - • • 4.4944
94••9•
9 0 4 949400
0000
NOA No.: 13-0514.10
Mu1MMADeCOUNW Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 4 of 26
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
1.
Dekfast Fasteners #l2, #14
Insulation fastener for wood,
SFS Intec, Inc.
& #15 HS
steel and concrete decks
2.
Dekfast Galvalume Steel
Galvalume hex stress plate.
2 7/8" x
SFS Intec, Inc.
Hex Plate
31/411
3.
Dekfast Dekflat Round
Polypropylene locking
3" x 3 '/4"
SFS Intec, Inc.
Plastic Lock Plate
plate.
4.
#12 & #14 Roofgrip
Insulation and membrane
Various
OMG, Inc.
fastener
5.
Flat Bottom Metal Plate
A2 -SS aluminized steel plate
3" square
OMG, Inc.
6.
Plastic Plate
Polyethylene stress plate
3.2" round
OMG, Inc.
7.
Tru -Fast #14 HD Fastener
Insulation fastener for steel and
Altenloh, Brinck & Co.
wood decks
U.S., Inc.
8.
Tru -Fast 3" Metal Insulation
Round Galvalume AZ50 steel
3.23 round
Altenloh, Brinck & Co.
Plate
plate
3" round
U.S., Inc.
9.
Polygrip Fasteners # 12, # 14
Insulation fastener for wood,
Various
Polyglac a MA, Inc

steel and concrete decks
00000.
•
10.
Polygrip Hex Plates
Galvalume hex stress plate.
2 7/8" x
• • •: 4lyglass ORA, Inc • • • • � •
3 I/4"
000000
0000..
11.
Dekfast Galvalume Steel 3
3" round galvalume AZ50 steel
3" round
..
0:::: -SFS Iht@�,�nc. • • • • .
in. Round
plate
12.
Millennium One-Step�
Insulation Adhesive
Various
.. .. 0000..
Adco 19?c dhcts 6
Foamable Adhesive
• • • • • • •
•
.
. . . . 0
...... 0009
. 6 6 .6060.
.0 . 6000 6 .
00*0
MIAMFDADE COUNTY NOA No.: 13-0514.10
... � Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 5 of 26
APPROVED SURFACING:
TABLE 4
Product Product
Name Description
PG200 Non-Fibered Roof Coating A non fibered asphaltic coating used
to add life and rejuvenate existing
BUR roofing substrates.
PG300 Fibered Roof Coating An asphalt cutback fibered roof
coating. May be applied by brush or
spray equipment to rejuvenate aged
BUR
PG600 Non-Fibered Aluminum
Roof Coating
PG650 Fibered Aluminum Roof
Coating
PG700 White Elastomeric Roof
Coating
Application
Specification Manufactur
Rate
er
1'/Z-2 gal/sq
TAS 140 Polyglass
Polyplus 65 Premium Fibered
USA, Inc.
1'/2-2 gal/sq
ASTM D4479 Polyglass
Polyplus 60 Premium Non-
USA, Inc.
Non-fibered aluminum roof coating. '/2-1 gal/sq
Fibered aluminum roof coating. 1'/2-2 gal/sq
A premium white elastomeric acrylic 1-1'/Z gaUsq
based roof coating (water-based). A
polyester fabric may be used for
reinforcement with this coating.
PG800 Non-Fibered Asphalt An asphalt base, un-fibered clay
Emulsion Roof Coating
emulsion
PG850 Fibered Asphalt Emulsion
An asphalt base, fibered clay
Roof Coating
emulsion
Polyplus 65 Premium Fibered
Fibered aluminum roof coating.
Aluminum Roof Coating
Polyglass
Polyplus 60 Premium Non-
Non-fibered aluminum roof coating.
Fibered Aluminum Roof Coating
ASIM 132824
Polybrite 70 White Elastomeric
Roof Coating
Gravel
Slag
A premium white elastomeric acrylic
based roof coating (water-based). A
polyester fabric may be used for
reinforcement with this coating.
To be installed in a flood coat of
approved asphalt at 60 lbs/sq
To be installed in a flood coat of
approved asphalt at 60 lbs/sq
ASTM D2824
Polyglass
Type I
USA, Inc.
ASTM D2824
Polyglass
Type III
USA, Inc.
ASTM D6083
Polyglass
USA, Inc.
3 gal/sq in
ASTM D1227
Polyglass
two coats
USA, Inc.
3 gal/sq in
ASTM D 1227•
Polyglass
two coats
•
..jT.S'A, Inc,...
1'/2-2 gal/sq
ASIM 132824
• • • Pojyglass • .
" i' pill
USA, Inc. ""'
'/Z-1 gal/sq
•.....
ASTAQA2824..
• .
Polyglast 00
• •79ype I
: ' VT A, Inc* • • • •
••••••
. .. .•..•
1-1'/Z gal/sq
. ..
Aye**p6083
...
*.olyglass....••..
'
USA,Inc,,,.:,
• .
• • .
400 lbs/sq
N/A
• • • •Generic
300lbs/sq
N/A
Generic
t�uwtt DAae coun�r�r NOA No.: 13-0514.10
... • Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 6 of 26
EVIDENCE SUBMITTED:
Test Agency
Test Name/Report
Report No.
Date
Factory Mutual Research
4470
J.I.2W7A7.AM
08.04.94
Corporation
4450
2D5A9.AM
06.22.99
4470
J.1.3001334
02.15.00
4470
J.I.3000857
01.12.00
4470
J.I.3004091
01.12.00
4470
3012321
07.29.07
4450
3014751
08.27.03
4450
3019317
06.30.04
4470
3014692
08.05.03
Trinity ERD
TAS 114
11752.09.99-1
02.08.00
TAS 114
02764.09.05
09.09.05
TAS 114
020843.02.05-1
02.10.05
TAS 114
02762.03.05
03.30.05
TAS 117(B) -ASTM D903
020841.06.04
06.02.04
TAS 114
P1734.07.06 -R1
02.27.07
TAS 114
02843.07.07
07.23.07
TAS 114
P1738.02.07
02.05.07
TAS 114
P1739.01.07
01.23.07
TAS 117(B) -ASTM D6862
C8500SC.11.07
11.30.07
ASTM D6164 / ASTM D6222
P10490.08.08
08.13.08
ASTM D6164 / ASTM D6222
P10490.10.08 -RI
.IV.63.08
ASTM D6222
P7400.03.08-RZ ..
lei/8g/08
TAS 114(D) — ASTM D 1876
P10070.10.08
*f0/99,t48
ASTM D6222
P 10490.10.08-2r : : : : :
10/30/08
FM 4470 & TAS 114
P33970.03.11 ....
,Q3/15/1 I
ASTM D6163 / ASTM D 4601
P33960.03.11 '.... *
:V14SA 1
ASTM D6164
P37590.07.13-1• •: a e:
V7 j92/13
ASTM D6164
P37590.03.13-3Ae • •
09f@6/13
ASTM D6163
P37590.03.13 -2-$f':':
02/05/13
ASTM D6222
P37590.09.13 0
:(1`WoM3
PRI Asphalt Technologies
ASTM D6222
PUSA-061-02-02�e
Oj:28/08
ASTM D6222
PUSA-062-02-02
12/04/08
ASTM D6163
PUSA-064-02-02
02/27/08
sees..
..sees
0 e
.6000.
066.
. .
sees.
sees..
•.0060
00..00
0 e
MIAMI•DADE c � NOA No.: 13-0514.10
� � Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 7 of 26
APPROVED ASSEMBLIES:
Membrane Type: SBS/APP
Deck Type II: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Elastobase or an ASTM D4601, Type H approved base sheet fastened to the deck as
described below:
Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c. in
a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet.
Fastening #2: Attach base sheet using OMG Roofgrip Fasteners and Flat Bottom Plates, Dekfast #14 with
Galvalume Steel Hex Plates or Polygrip Fasteners #14 with Polygrip Hex Plates or Tru -Fast #14
HD Fasteners with 3" Metal Insulation Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two
equally spaced staggered rows in the center of the sheet.
One or more of the following
Base Insulation Laver (Optional) Insulation Fasteners Fastener
able 3 . i;'eWl /ft'
. . ... ......
Any approved Polyisocyanurate listed in Table 2 •
Minimum l" thick N/A •••••• •N;A ••••�•
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved°1184 asphi t°within tIfe
EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application"Sfandard UW 117 for : • 6 •
insulation attachment. Insulation listed as base layer only shall be used only as base lra�crs *with a s®eond layer . •
0.
.0 0000 ......
of approved top layer insulation installed as the final membrane substrate. Compositejgsulgtion panels may be ••
used as a top layer placed with the polyisocyanurate side facing down. ....:.
Top Insulation Laver Insulation Fastener Fastener • • •.
able 3 •Bt>f�tz
DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/" thick N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range
and at a rate of 20-40 lbs/100 W. Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or
Elastoflex SA V PLUS FR self -adhered.
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 8 of 26
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA
P
FR self adhered.
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure:
-52.5 psf, (See general limitation #7.)
• • •Y••
•••0••
•0000• ••
0000•0
•
600000 i
• •
0000 •• •
• •
• • • • •
00
•
•00.0• •
•
• • • •
•000••
• • •
•
•00000
fees
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 9 of 26
Membrane Type:
Deck Type 1I:
SBS/APP
Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood
screws at 6" o.c.
System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System limitations apply.
Anchor Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening: Attach base sheet using OMG Roofgrip Fasteners and Flat Bottom Plates spaced 12" o.c. in a 4"
lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet.
One or more of the following
Base Insulation Laver (Optional) Insulation Fasteners Fastener
able 3 Density/W
Any approved Polyisocyanurate listed in Table 2
Minimum 1" thick N/A NIA
Top Insulation Laver Insulation Fasteners Fastener
able 3 Density/fe
DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board .••••.
Minimum'/" thick N/A ••• •••1\/A ••••�•
0 . 0
000000 .. 000000
Note: All insulation shall be adhered to the anchor sheet in full mopping of approvgd.Qat asphalt within the
EVT range and at a rate of 2040 lbs/100 W. Please refer to Roofing Application*Standard 44AS.117 for' 0 • •
insulation attachment. Insulation listed as base layer only shall be used only as base fayws with aseom;d layer;•••
of approved top layer insulation installed as the final membrane substrate. Composite"#tion l3a4el9 jnay 000•••
used as a top layer placed with the polyisocyanurate side facing down.
00 00 0000 000000
0000.. . •
Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V 17146Cr•'0• 06•••,
Elastoflex SA V PLUS FR self -adhered. •.. • • 0000 """
00:0
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P
FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure: -60 psf; (See general limitation #7.)
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 10 of 26
Membrane Type:
Deck Type 1I:
SBS/APP
Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood
screws at 6" o.c.
System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of an ASTM D4601, Type II approved base sheet fastened to the deck as described
below:
Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c.
in a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet.
One of more of the following:
Base Insulation Laver (Optional) Insulation Fasteners Fastener
able 3 Density/fe
Any approved Polyisocyanurate listed in Table 2
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the
EVT range and at a rate of 2040 lbs/100 fe. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer
of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down. ....
. . .... ......
Top Insulation Laver Insulation Fasteners • •P s uer
(Table3) • • • ; • • Deni" /ftz
Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Roof Board • • •
Minimum '/e" thick N/A : 0 491A • • • • •
...... . .. .....
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the'EVT ranglr
and at a rate of 2040 lbs/100 W. Please refer to Roofing Application Standard:IM:117 for Insulation '.
attachment. Insulation listed as Base Layer only shall be used only as base layer§ with' a se&md layer of� • • •
approved top layer insulation installed as the final membrane substrate. Composite U �uiation panej%Viay b�• • • •;
used as a top layer placed with the polyisocyanurate side facing down. so:*
Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or
Elastoflex SA V PLUS FR self -adhered.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P
FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 11 of 26
Maximum Design
Pressure: -60 psf; (See general limitation #7.)
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 12 of 26
0000
. .
0000
0000..
0000..
0000..
0000
..
0000
..
..0..
......
..
.0...0
.. ..
0000
0000.0
.....•.
00
. .
0000..
0000..
.
0000..
..
.0..
0000
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 12 of 26
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32° or greater plywood or wood plank.
System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Elastobase or Elastobase P fastened as below:
Fastening: 12 ga. Annular ring shank nails and 1-5/8" tin -caps attached 6" o.c. in 4" lap and 6" o.c. in four
equally spaced staggered rows.
Base Insulation Laver Insulation Fasteners Fastener
able 3 Density/ftp
Polytherm, ACFoam II, ACFoam III, Polytherm-H, H -Shield, H -Shield CG, Multi -Max FA3, or ENRGY-3
Minimum 1" thick N/A N/A
Insulation:
Adhered with Millenium One -Step Foamable Adhesive applied over rows of tin -caps in
continuous rows 7" o.c.
Base Sheet:
One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or
Elastoflex SA V PLUS FR self -adhered.
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polr)da: SA P
FR self adhered. • • • •
*go::* •••;•
Surfacing:
(Optional) Install one of the approved surfacing products listed in TaUlE Vfb obtain desi$id
*Gone*
coating or required fire classification. 000000 e
•
......
.... . ••
•••.•
Maximum Design
.
• • • • • • go
..:..'
Pressure:
Pressure:
-
-60 psf; (See general limitation #7.)'
• • • • • •
. . . .
..e...
MIAMPDADE CJNOA
No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 13 of 26
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type C(1): All layers of insulation are mechanically attached to roof deck. Membrane is subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following
Base Insulation Laver
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5" thick
Insulation Fasteners Fastener
able 3 Density/fe
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Toa Insulation Laver
Approved High Density Wood Fiber
Minimum 1/2" thick
Insulation Fasteners Fastener
able 3 Density/ft2
1:1.33 ftz
DensDeck • ••••
Minimum 1/4" thick l 009 7:io33 ftz "":'
Go . Geo G •
Note: All layers of insulation shall be mechanically attached using the fastener Je*n*s*IF listed algove. Th""..
ge •
insulation panels listed are minimum sizes and dimensions; if larger panels are used* iog jsumber of i[asteneiV `:
shall be increased maintaining the same fastener density. Please refer to Roofing Appjption Staddafd RA& G G e
117 for insulation attachment. .Goose 00 09:000
• . . G
Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastolex M V FR, or*
Elastoflex SA V PLUS FR self -adhered. :...:. e Soso
0
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SLAP, Pgl o esko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P
FR self adhered.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure: -52.5 psf; (See General limitation #7.)
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 14 of 26
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32° or greater plywood or wood plank, fastened with 8d common nails at 4" o.c.
System Type C(2): All layers of insulation are mechanically attached to roof deck. Membrane is subsequently
adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5" thick
Insulation Fasteners Fastener
able 3 Density/fe
N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Ton Insulation Laver
Approved High Density Wood Fiber
Minimum %" thick
DensDeck
Minimum '/a" thick
Insulation Fasteners Fastener
able 3 Density/W
1:1.33 ft2
1:1.33 W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS
117 for insulation attachment. 000000 •••"'
Base Sheet: One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, ElastoR" f" V FR, or " ""' •
Elastoflex SA V PLUS FR self -adhered. """ % • • • •
0
• .
0 . 0
. .. 0000.
Membrane: One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko �►��' SAP, Pplyfr%sko . •;..'
..•00•
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, P4yl�,ifl or PdIVUYSA P .00 0 0 0
FR self adhered.
0000.. • •
. . . . .0000•
0000..
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to pbtainodesired ;.....
coating or required fire classification. .. . 0000 0 •
.00•
Maximum Design
Pressure: -67.5 psf; (See General limitation #7.)
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 15 of 26
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with wood screws at 6" o.c.
System Type C(3): All layers of insulation are mechanically attached to roof deck. Membrane is subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following:
Insulation Laver
ENRGY-3, Polytherm-H, H -Shield or Polytherm
Minimum 1.5" thick
Insulation Fasteners Fastener
Table 3 Density/ft2
1,7or9 1:1.33W
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The
insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners
shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Base Sheet:
One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or
Elastoflex SA V PLUS FR self -adhered.
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P
FR self adhered.
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
9999
Maximum Design
'
9999. .
• 9999
•
Pressure:
-82.5 psf; (See General limitation #7.)
900.90 00
9900.0
090000
9999..
0009 ..
. .
. .
9999 ..
..
..��
00900. . .0
9.0.9
. 9 .
90 00 9999
9999..
.
...9.9
04,
• 0 . .
00..0.
9999..
9
966
9999..
09 0 0000
0 •
- NOA No.: 13-0514.10
MIAMMDADECOUNTY
� ® Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 16 of 26
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type D(1): All layers of insulation and base sheet simultaneously attached, membrane subsequently
adhered..
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver
Any approved Polyisocyanurate listed in Tablet
Minimum 1" thick
Ton Insulation Laver (Optional)
Fesco Board
Minimum '/" thick
Approved High Density Wood Fiber
Minimum 1/2" thick
DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum 1/" thick
Insulation Fasteners Fastener
able 3 Density/fe
N/A N/A
Insulation Fasteners Fastener
able 3 Density/W
N/A N/A
N/A N/A
N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a
minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4
ft., and four fasteners for any insulation board having no dimension greater than 8 ft.
Base Sheet:
One or more plies of Elastobase or Elastobase P fastened to the deck as described beloVA
. . 0000 0000..
Fastening:
Attach base sheet using OMG # 14 Roofgrip Fasteners and Flat Bottom dates, DekfM.#1; with
Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygdo "ex Plates of Trufasi"• � •
#14 HD Fasteners with 3" Metal Insulation Plates spaced 12" o.c. in a'40 �l'ai'and 12'� o in twa • • • •
equally spaced staggered rows in the center of the sheet. •
09990
Ply Sheet:
0000.. . .. 0000.•
One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastotle0� 50V FR' o$ .. 000 9 •
Elastoflex SA V PLUS FR self -adhered. 0 9 0 0 0 9 9 ••
•
0
. . . . 000000
Membrane:
0000..
One ply ofPolyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko�PVW, P8lyfresko :0909:
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PoI jKooi or Polyflex %A P 0
0000
FR self adhered.
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 17 of 26
Maximum Design
Pressure: -52.5 psf; (See General limitation #7.)
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 18 of 26
0000
. .
0.06
.00..0
.0000.
..
0060.0
000.0.
0000..
0000
..
6 .
. .•.•
0000
.0000
.
000000
0000
0000.9
.....0
on
.
0000..
......
6
.0000.
..
0000
0*06
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 18 of 26
Membrane Type:
Deck Type 1I:
SBS/APP
Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 wood
screws at 6" o.c.
System Type D(2): All layers of insulation and base sheet mechanically fastened, membrane subsequently adhered.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver
Any approved Polyisocyanurate listed in Table 2
Minimum 1" thick
Top Insulation Laver (Optional)
Fesco Board
Minimum %" thick
Approved High Density Wood Fiber
Minimum %" thick
DensDeck, DensDeck Prime, SECUROCK Gypsum -Fiber Roof Board
Minimum'/" thick
Insulation Fasteners Fastener
able 3 Density/fe
N/A N/A
Insulation Fasteners Fastener
able 3 Density/ft2
N/A N/A
N/A N/A
N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a
minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4
ft., and four fasteners for any insulation board having no dimension greater than 8 ft.
Base Sheet: One or more plies of Elastobase or Elastobase P fastened to the deck as described bejQy,
. 0000 0.0000
Fastening: Attach base sheet using OMG Roofgrip Fasteners and Flat Bottom Plaiw0pked lNgoc . in a 4" •
ee
lap and 12" o.c. in two equally spaced staggered rows in the center of th&shaet. • • 006000
000000 0 0
Ply Sheet:
One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastolj2at S%V FR; bs '.
0000..
Elastoflex SA V PLUS FR self -adhered. "'
•
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko jl+V&P, PolAesko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PcgyKboi or Pclyflex SA P . • • •: •
FR self adhered. : * s o
00 0 0000
0000..
0
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to obtain%%I� ed
coating or required fire classification.
Maximum Design
Pressure:
-60 psf; (See General limitation #7.)
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 19 of 26
Membrane Type: SBS/APP
Deck Type 1: Wood, Non -Insulated
Deck Description: 19/32" or greater plywood or wood plank.
System Type E(1): Base sheet is mechanically attached to roof deck.
All General and System Limitations apply.
Base Sheet: One ply of Elastobase or Elastobase P fastened to the deck as described below:
Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8" diameter tin caps spaced 8" o.c. in
a 4" lap and 8" o.c. in three equally spaced staggered rows in the center of the sheet.
Fastening #2: Attach base sheet using OMG #14 Roofgrip Fasteners and Flat Bottom Plates, Dekfast #14 with
Dekfast Galvalume Steel Hex Plates, Polygrip Fasteners #14 with Polygrip Hex Plates or Trufast
#14 HD Fasteners with 3" Metal Insulation Plates spaced 12" o.c. in a 4" lap and 12" o.c. in two
equally spaced staggered rows in the center of the sheet.
Ply Sheet:
One or more plies of Elastoflex SA V, Elastoflex SA V PLUS, Elastoflex SA V FR, or
Elastoflex SA V PLUS FR self -adhered.
Membrane:
One ply of Polyfresko SBS SAP, Polyfresko SBS SAP FR, Polyfresko APP SAP, Polyfresko
APP SAP FR, Elastoflex SA P, Elastoflex SA P FR, Polyflex SA P, PolyKool or Polyflex SA P
FR self adhered.
Surfacing:
(Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General limitation #7.).
0000
. . 0000
0000..
0000..
0000..
0000 ..
0000 . ..
0000.
•• •• 0000
0000:9
000000 •
•
• • •
00000•
•00000
• • •
00000•
•• • 0000
• •
•
0000
NOA No.: 13-0514.10
MInMMAD, COUNTY Expiration Date: 10/11/17
�ffjumApproval Date: 09/26/13
Page 20 of 26
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
I . Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20401bs./sq., or mechanically attached using the fastening pattern of the
top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at
each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the
strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt
application of either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 Ibf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener
spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117.
7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing
Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registeredeiWessional
Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is'secificaRy •referredr • • •
within this NOA, General Limitation #9 will not be applicable.) ' • •' • • • • • '.
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing terminatict edogns shall coflfbrm td
Roofing Application Standard RAS I 1 I and applicable wind load requirements. • • •"' :....:
9. The maximum designed pressure limitation listed shall be applicable to all roof pressurs'21oV c (i.e. few • • • �'
49
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permittedfo;:6anceifasl%ping at. •;• •
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this ligytoAdn is spe. f filly *fee:*
referred within this NOA, General Limitation #7 will not be applicable.) e 00:6:
•
. e . . ....e.
ee.e..
END OF THIS ACCEPTANCE •' • • • • •
•• • ecce • •
•
ecce
NOA No.: 13-0514.10
Expiration Date: 10/11/17
Approval Date: 09/26/13
Page 26 of 26
TdU.R14571 - Roofing Systems
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/Showpa...
"ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT' (self adhered).
Ply Sheet (Optional): — "ELASTOBASE", "XtraFlex SBS GLASS Base"(poly/sand), heat fused or mechanically fastened, or "ELASTOFLEX
SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered).
Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", "ELASTOFLEX
SA V FR HT", (self adhered) or "POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "POLYFRESKO G FR", "DUFLEX G FR", "XtraFlex
APP Dual", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR", "ELASTOFLEX VG FR", "XtraFlex SBS POLY G "XtraFlex SBS POLY G T,
.4DA144X.55S.QIAUQG—'"Xtr-aFlax St3S-GLASS GT' or "ELASTOSHIELD TS G FR", heat fused.
22. Deck: C-15/32
Incline: 1/2
Insulation (Optional): — Polylsocyanurate 1.5 in. (min.) with all joints staggered 6 -in. (min.) from the plywood joints.
Base Sheet: — Type G2, mechanically fastened followed by "ELASTOBASE", "XtraFlex SBS GLASS Base", mechanically fastened.
Ply Sheet (Optional): — "ELASTOFLEX SA V PLUS FR" , "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered).
Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", or "DUFLEX G
FR", "XtraFlex APP Dual", "POLYFLD( G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "ELASTOFLEX S6 G FR", "POLYFRESKO G SBS FR",
"ELASTOFLEX VG FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY GT', "XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or
"ELASTOSHIELD TS G FR", heat fused.
23. Deck- NC
Incline: 2
Insulation (Optional): — Atlas Roofing "ACFoam III" or "ACFoam Ir or Hunter Panels "H -Shield", any thickness.
Base Sheet: — "ELASTOBASE", "XtraFlex SBS GLASS Base"(poly/sand), heat fused or mechanically fastened or "ELASTOFLEX SAV FR",
"ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT', (self adhered).
Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR", "POLYFRESKO G SBS SA P FR", "ELASTOFLEX
SA V FR HT', (self adhered) or "POLYFLEX G FR", "XtraFlex APP G HP", "Xtraflex APP G FR", "POLYFRESKO G FR", "XtraFlex APP Duar,
"DUFLEX G FR" "ELASTOFLEX S6 G FR',-"POLYFRESKO G SBS FR", "ELASTOFLEX VGFR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T,
"XtraFlex SBS GLASS G", "XtraFlex SBS GLASS GT" or" ELASTOSHIELD TS G FR", heat fused.
24. Deck: C-15/32
Incline: 3
Insulation (Optional): — Polylsocyanurate, perllte, wood fiber or polyisocyanurate/periite board, any thickness.
Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck@, mechanically fastened with all joints staggered 6 in. from the plywood joints.
Base Sheet: — "ELASTOBASE", "XtraFlex SBS GLASS Base" (poly/sand), mechanically fastened.
Ply Sheet (Optional): — "ELASTOFLEX SA V PLUS FR" , "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered).
Membrane: — "ELASTOFLD( S6 G FR", "XtraFlex SBS POLY G", "XtraFlex SBS POLY G T" or "POLYFRESKO G SBS FR", heat fused.
25. Deck: NC
Incline: 3
Insulation (Optional) Atlas Roofing "ACFoam III" or "ACFoam II" or Hunter Panels "H -Shield", any thickness.
Base Sheet: — "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT" (self adhered).
Membrane: — "POLYFLEX SA P FR", "POLYFRESKO G APP SA P FR", "ELASTOFLEX SA P FR" or "POLYFRESKO G SBS SA P FR" (self
adhered).
26. Deck: NC
Incline: 1/2
Base Sheet: — Type G1 or G2, mechanically fastened.
Membrane: — "POLYFLEX G", "XtraFlex APP G HP TOR", "Xtraflex APP G" or "POLYBOND G", heat fused.
0000
27. Deck: NC Incline: 3 • '
• • 0000
••••�•
Membrane: — "POLYFLD( SA P FR", "POLYFRESKO G APP SA P FR", "POLYFRESKO G SBS SA P FR"or "ELAftFLE!i( SA P F'Ifleelfi
•
adhered). 6060•• '•
""'•
•
••••s• •
• •
0000••
28. Deck. NC Incline: 1 0000 • • •
• •
• • 0 • • • •
• • • • • •
Insulation (Optional): — Polyisocyanurate, any thickness.
Base sheet (Optional): — "ELASTOFLEX SA V", "ELASTOFLEX SA V PLUS", "Xtraflex SBS Base SA" or "EL1k""-O( SA VtAsE'lwr,
0000•
self -adhered or "ELASTOBASE", "XtraFlex SBS GLASS Base" (poly/sand), mechanically fastened. •• •• 0000
""0'
Membrane: — "POLYFLD( SA P", "Xtraflex APP G SA" "XtraFlex Kool APP G SA", or "POLYFRESKO G APP SW*"sa f•adhered or YPOLYFLEX 00
FG FR", heat fused. • '
• • • •
*see**
0000••
• •
29. Deck: C-15/32 Incline: 1/2 ••• •
0000••
•• 0 0000
• •
•
Insulation: — Polyisocyanurate (2 In. min), glass fiber (15/16 in. min), periite/polyisocyanurate composite, perlite/urethanlCaAlpsite (2
In. min).
Barrier Board: —1/4 In. (min) G -P Gypsum DensDeck®, mechanically fastened, with 6 in. offset to plywood joints.
Base Sheet: — "ELASTOFLEX S6", "XtraFlex SBS POLY Base", "ELASTOFLB( P -C" (heat fused or mechanically fastened).
Membrane: — "ELASTOFLD( S6 G", "ELASTOFLEX S6 G -C" or "POLYFRESKO G SBS', (heat fused).
30. Deck- NC Incline: 1/2
Insulation (Optional) — Atlas Roofing "ACFoam III" or "ACFoam II", any thickness.
Base Sheet: — "ELASTOFLEX SA V PLUS FR", "ELASTOFLEX SA V FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered).
Membrane: - "POLYKOOL SA" or "XtraKooi APP S SA", (self adhered).
5 of 10 3/26/2014 8:54 AM