Loading...
RC RT-14-2265Miami Shores Village Building Department OCT 16 2014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 FBC 20 a® BUILDING Master Permit No.➢mac r 9 PERMIT APPLICATION Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING REVISION ❑ EXTENSION EJRENEWAL ❑PLUMBING ❑ MECHANICAL Ej PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: < ?N� =Sf /'` City: Miami Shores County: Miami Dade Zip: —9313e Folio/Parcel#:_ //-- 320C- ��" 1.5-66, Is the Building Historically Designated: Yes NO X Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): G(.1,1 MAq �1S �� G� Phone#: _30S 62+3 0GiG& Address: 15-� W s -k sr sty-44?_r City: MkcLrt�l b---ec-tC-h State: 'R_ Zip: 0 Tenant/Lessee Name: Phone#: Email: MC1M V\56nCh Cory, CONTRACTOR: Company Name: Phone#: Address: City: Qualifier Name: State: hone#: State Certification or Registration #: Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: � ueq i, �er-tfi cc rn On Specify color of color thru tile:, Submittal Fee $ Permit Fee $ Scanning Fee $ Technology Fee $ Structural Reviews $ (Revised02/24/2014) Radon Fee $ Training/Education Fee $ CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature OWNER or AGENT The foregoing instrument was acknowledged before me this t c day of (�7/` 20 by ko,&4M , who is ersonally known o me or who has produced as identification and who did take an oath. ISABEL FERNAMM NOTARY PUBLIC: # * MY COMMISSION tFFCM EXPIRES: August 28,2D17 �•4j�occ�.�'oe ThtuBudgetNotuygenlc� Sign: Print: l �AhhD Seal: APPROVED BY i4 (Revised02/24/2014) Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of me or who has produced 20 , by , who is personally known to identification and who did take an oath. NOTARY PUBLIC: Sign: Print: Seal: as Plans Examiner Zoning 'Structural Review Clerk AMERICAN BUILDING ENGINEERS@INC. Professional Engineering License # 4732 Threshold Inspection License # 467 October 9, 2014 Dade DESIGN • CONSTRUCTION • INSPECTION State Licensed Roofing Contractor CCC#0045913 State Licensed General Contractor. CGC#0044407 File # R1014-023 (305) 681-5563 Mr. Ismael Naranjo Director/Building Official City of Miami Shores Village 10050 Ne 2 Ave Miami Shores, FL 33138 ILj Phone: (305) 795-2207 /02 RE: 699 NE 92nd St, Miami Shores, FL 33138 • Folio No.: 11-3206-014-1560 Dear Mr. Naranjo, This is a one-story 4 -unit apartment concrete building. The exterior walls are covered with plaster on concrete block. The roof is pitched and covered with Spanish S Tile roof. The building was found to be in overall good condition and is structurally and Broward electrically safe for its use and present occupancy. Accordingly, I am recommending (954) 739-5099 the building for recertification. Fax: (954) 739-5153 In order to avoid any possible misunderstanding, we wish to specifically advise that nothing in this report should be construed, either directly or indirectly, as a guarantee of condition of any portion of this structure. To the best of our knowledge and ability, this report represents an accurate appraisal of the present conditions of this building, based upon visual examination of observed conditions to the extent reasonably possible. No warranties or representations are intended, nor should any be construed. • 0` kAIIIIII//�� Sincerely, \���� oplud �� American B din inee Z Abe Bo E g �': No 38553 P.E. 5 0` 01 �,�W W ' tU zz gTOF Palm Bch. rO�� FLOR\Op �//; (561) 243-3939 � j�S�ONP� ����\ fIII1 Corporate Headquarter: 1842 East Oakland Park Boulevard, Fort Lauderdale, Florida 33306 www.abeincusa.com • info@abeincusa.com MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING STRUCTURAL RECERTIFICATION INSPECTION COMMENCED INSPECTION MADE BY: Abe Borujerdi Date: October 8, 2014 SIGNATURE: INSPECTION COMPLETED Date: October 8, 2014 ADDRESS: American Building Engineers, Inc. 1. Description of Structure: a. Name of title: KAY MAUNSBACH PRINT NAME: Abe Borujerdi, P. E. TITLE: Registered Professional Engineer 1842 East Oakland Park Blvd. Ft. Lauderdale, Florida 33306 PHONE: (954) 739-5099 b. Street address: 699 NE 92 ST, Miami Shores, FL 33138-2961 c. Legal description: MIAMI SHORES SEC 3 PB 10-37 LOT 21 & BEG SW COR LOT 22 E25FT NW131.23FT W7FT S129.99FT TO POB BLK 63 d. Owner's name: KAY MAUNSBACH e. Owner's mailing address: 754 WEST 51 ST MIAMI BEACH, FL 33140 f. Building Official Folio Number: 11-3206-014-1560 g. Building Code Occupancy Classification: R h. Present use: MULTIFAMILY i. General description, type of construction, size, number of stories, and special features: This is a 4 -units apartment building. The exterior walls are covered with plaster on concrete block walls. The roof is pitched and covered with Spanish S Tile roof. j. Additions to original structure: No. N 3 553 STATE orb i Fo'g Oleo '9 St, Miami Shores, FL 33138 I QN0 IN gal 2. Present Condition of Structure: a. General alignment (note good, fair, poor, explain if significant) 1. Bulging: FAIR 2. Settlement: FAIR 3. Deflections: FAIR 4. Expansion: FAIR 5. Contraction: FAIR b. Portions showing distress (note beams, columns, structural walls, floors, roofs, others). None C. Surface conditions - describe general conditions of finishes, noting cracking, spalling, peeling, signs of moisture penetration and stains. Plaster walls - fair d. Cracks - note location in significant members. Identify crack size as HAIRLINE if barely discernible; FINE if less than 1 mm in width; MEDIUM if between 1 and 2 mm in width; WIDE if over 2 mm. N/A e. General extent of deterioration - cracking or spalling of concrete or masonry; oxidation of metals; rot or borer attack in wood. N/A f. Previous patching or repairs: g. Nature of present loading - indicate residential, commercial, other estimate magnitude. Residential h. Availability of original construction drawings - location: None ��I11111II//I \\ B®RU✓�`��''� No 38553 O� •. STATE OF ' �; 41%6-014-1560 699 NE 92nd St, Miami Shores, FL 33138 AMERICAN BUILDING ENGINEERS' 3. Inspections: a. Date of notice of required inspection: b. Date(s) of actual inspection: October 1, 2014 C. Name and qualification of individual submitting inspection report: Abe Borujerdi, P.E. / American Building Engineers, Inc. d. Description of any laboratory or other formal testing, if required, rather than manual or visual procedures: N/A e. Structural repair - note appropriate line: 1. None required: XXX 2. Required (describe and indicate acceptance): 4. Supporting data: a. 7 sheets written data b. -0- photographs C. -0- drawings or sketches 5. Masonry Bearing Walls - indicate good, fair, poor on appropriate lines: a. Concrete masonry units: Fair b. Clay tile or terra cotta units: ---- c. Reinforced concrete tie columns: ---- d. Reinforced concrete tie beams: Fair e. Lintels: ---- f. Other type bond beams: ---- g. Masonry finishes -exterior: \\\\I 1. Stucco: (plaster) fair �`` PgE®/..& uC4s�:;o4�`� 2. Veneer: ____ N0 38Sg3 l 3. Paint only: fair, _ - 4. Other (describe): ---- T ///1i Ei�W Folio: 11-3206-014-1560 699 NE 92nd St, Miami Shores, FL 33138 AMERICAN BUILDING ENGINEERS® h. Masonry finishes - interior: 1. Vapor barrier: ---- 2. Furring and plaster: good 3. Paneling: good 4. Paint only: good 5. Other (describe): ---- Cracks: 1. Location - note beams, columns, other: None 2. Description: j. Spalling: 1. Location - note beams, columns, other: None 2. Description: k. Rebar corrosion - check appropriate line: 1. None visible: XXX 2. Minor - patching will suffice: 3. Significant - but patching will suffice: 4. Significant - structural repairs required: (Describe) 1. Samples chipped out for examination in spall areas: 1. No: XXX 2. Yes - describe color texture, aggregate, general quality: 6. Floor and Roof Systems: a. Roof: .. = =0: 8S6 3 = ®� X012ml`� �n �c!'�'•: ,ter•o.,'�io11 -32 .Ok4-1560 dSt,:6992�oA0 '.,N' rami• es\FL 33138 rill► 1. Describe (flat, slope, type roofing, type roof deck, condition): Pitched Roof t 15 years old. Fair Condition. 2. Note water tanks, cooling towers, air conditioning equipment, signs, other heavy equipment and condition of supports: NONE. 3. Note types of drains and scuppers and condition: — Sloped to perimeter Fair Condition. b. Floor system(s): 1. Describe (type of system framing, material, spans, condition): 1St and 2nd floor — Concrete Deck C. Inspection - note exposed areas available for inspection, and where it was found necessary to open ceilings, etc. for inspection of typical framing members: Attic 7. Steel Framing Systems: a. Description: None b. Exposed Steel - describe condition of paint and degree of corrosion: XXX C. Concrete or other fireproofing - note any cracking or spalling, and note where any covering was removed for inspection: XXX d. Elevator sheave beams and connections, and machine floor beams - note condition: N/A 8. Concrete Framing Systems: a. Full description of structural system: Concrete block walls on concrete footing; concrete beams and columns. b. Cracking: ��� AREF & a tic O'Q14 4 = m Foix :-320j014-1560 N T9r 69p N>? 92°d St, �Q2•°��o`iami Shotes, F -L 33138 % 'ova'- 1. Not significant: XXX 2. Location and description of members affected and type cracking: C. General condition: Fair d. Rebar corrosion - check appropriate line: 1. None visible: XXX 2. Location and description of members affected and type cracking: 3. Significant but patching will suffice: 4. Significant - structural repairs required (describe) e. Samples chipped out in spall areas: 1. No: XXX 2. Yes, describe color, texture, aggregate, general quality: 9. Windows: a. Type (Wood, steel, aluminum, single hung, double hung, casement, awning, pivoted, fixed, other): single hung Fair b. Anchorage - type and condition of fasteners and latches: Fair C. Sealants - type and condition of perimeter sealants and at mullions: Fair d. Interior seals - type and condition at operable vents: Fair e. General condition: Fair 10. Wood Framing: a. Type - fully describe if mill construction, light construction jbM trusses: 'AG'� r Fol' 4 1560 (A 0 , � end St, i Shores;-Ft.3138 10 .o '~?�U 0 �I I major span b. Note metal fittings i.e., angles, plates, bolts, split pintles, pintles, other, and note condition: N/A C. Joints - note if well fitted and still closed: Fair d. Drainage - note accumulations of moisture: e. Ventilation - note any concealed spaces not ventilated: Fair f. Note any concealed spaces opened for inspection: Attic Opening (Up MU o•.. 11-3206-014=1560 6%N)� X92"d St, 'TL 33138 MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING ELECTRICAL RECERTIFICATION INSPECTION COMMENCED INSPECTION MADE BY: Abe Borujerdi Date: October 8, 2014 SIGNATURE: INSPECTION COMPLETED Date: October 8, 2014 ADDRESS: American Building Engineers, Inc. 1. Description of Structure: a. Name of title: KAY MAUNSBACH PRINT NAME: Abe Borujerdi, P. E. TITLE: Registered Professional Engineer 1842 East Oakland Park Blvd. Ft. Lauderdale, Florida 33306 PHONE: (954) 739-5099 b. Street address: 699 NE 92 ST, Miami Shores, FL 33138-2961 c. Legal description: MIAMI SHORES SEC 3 PB 10-37 LOT 21 & BEG SW COR LOT 22 E25FT NW131.23FT W7FT S129.99FT TO POB BLK 63 d. Owner's name: KAY MAUNSBACH e. Owner's mailing address: 754 WEST 51 ST MIAMI BEACH, FL 33140 f. Building Official Folio Number: 11-3206-014-1560 g. Building Code Occupancy Classification: R h. Present use: MULTIFAMILY i. General description, type of construction, size, number of stories, and special features: This is a 4 -units apartment building. The exterior walls are covered with plaster on concrete block walls. The roof is pitched and covered with Spanish S Tile roof. j. Additions to original structure: No. O -• Q :.�..o'� y o S� ]] 'QFolio. 11-:P($-014-1560 690 -NE 92❑d St, M� S�13res FL 33138 AMERICAN BUILDING ENGINEERS® MINIMUM INSPECTION PROCEDURAL GUIDELINES FOR BUILDING ELECTRICAL RECERTIFICATION 1. Electrical Service: OVERHEAD - COPPER 1. Size, Amperage: 4(100 amps) Fuses ( ) Breaker (X) 2. Phase: 30 (X) 10 ( ) 3. Condition: Good ( X) Fair ( ) Needs Repair ( ) 4. Comments: 2. Meter and Electric Rooms: 1. Clearances: Good (X ) Fair ( ) Requires Correction Comments: 3. Gutters: 1. Location: METER ROOM Good ( X ) Requires Repair Comments: 4. Electrical Panels: Location 1. Panel #1: Comments: Good (X ) Needs Repair ( ) 4 (100) AMP @ Utility Room 6. Branch Circuits: COPPER 1. Identified: Yes ( X ) Must be identified ( ) 2. Conductors: Good ( X ) Deteriorated ( k % k t I I Ntuq be replaced ( ) 3. Comments: copper wiring O�d. , a m _ =Q:�Ni w z: o• 206-014-1560 NE 92nd St, �� ' Miarrii:hores, FL 33138 1� AMERICAN BUILDING ENGINEERS® 7. Grounding of Service: Good (X ) Repairs Required ( ) Comments: 8. Grounding of Equipment: Good (X ) Repairs Required ( ) Comments: 9. Conduit Raceways: Condition: Good ( X ) Repairs Required ( ) Comments: 10. Conductor and Cables: Condition: Good ( X )Repairs Required ( ) Comments: copper wiring 11. Types of Wiring Methods Condition: Conduit Raceways: RIGID: Good ( X ) Repairs Required ( ) Conduit PVC: Good ( ) Repairs Required ( ) NM Cable: Good ( X ) Repairs Required ( ) BX Cable: Good ( ) Repairs Required ( ) 12. Conductors: Condition: Good ( X ) Repairs Required ( ) Comments: 13. Emergency Lighting: Good ( X } Repairs Required ( ) Comments: N/A 14. Bldg. Egress Illumination: Good ( X ) Repairs Required ( ) Comments: %I i i i i i I :0 m cc,,m• — ;�- o FBI 30;3206-014-1560 ���•• NE 92nd St, �i����9 G ' MiaYk1.'1hn--es, FL 33138 --------- -- - 15. Fire Alarm System: Good ( ) Repairs Required ( ) Comments: N/A 16. Smoke Detectors: Good ( X ) Repairs Required ( ) 17. 18. 19 20 21. 22. 23. Comments: Exit Lights: Good ( X ) Repairs Required ( ) Comments: Emergency Generator: Good ( ) Repairs Required ( ) Comments: N/A Wiring in Open or Under Cover Parking Garage Areas: Good ( X ) Require Additional Illumination ( ) Comments: Open or Undercover Parking Garage Comments: off street parking -Meet the Dade County chapter 8c-3 requirement Areas and Egress Illumination: Good ( X ) Require Additional Illumination ( ) Comments: N/A Swimming Pool Wiring: Good ( ) Repairs Required ( ) Comments: N/A Wiring to Mechanical Equipment: Good (X } Repairs Required ( ) Comments: General Additional Comments: ��`�� SAI Af- C `OCa' =D y O :� O to A Cb ,2•. w \01`01 '.,��ji�:'••..,, •.Fe` 3206-014-1560 699 NE 92nd St, 41ami Shores, FL 33138 CERTIFICATION OF COMPLIANCE WITH PARKING LOT ILLUMINATION STANDARDS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY Date: to 2* -12a19 RE: Case No.: Property Address Building Description: 699 pat- 92 $i OCT 28 2014 1. 1 am a Florida registered professional engineer or architect with an active license. 2. On de c+he' 20 rtj , at 8 : yO pm, I measured the level of illumination in the parking lot (s) serving the above referenced building. 3. Maximum r I— foot candle per SF, Minimum 9 foot candle per SF, Minimum to Maximum ratio �_: I z- , foot candle 4 average per SF. 4. The level of illumination provided in the parking lot a oes not meet the minimum standards for the occupancy classification of the building as established in Section 8C-3 of the Code of Miami -Dade County. \,Signature ani of Architect or Engineer PSE B.0% ulC�iys •.,A'% (Print N me) No � 38SS3 • � ' .•• �Tgr�D SRIDA oNAL ENC?\���• IIII% CERTIFICATION OF COMPLIANCE WITH PARKING LOT GUARDRAILS REQUIREMENTS IN CHAPTER 8C OF THE CODE OF MIAMI-DADE COUNTY DATE: 101241 Z -O y ®CT 2 8 2014 Re: Case No. Property Address: Bldg. No.: , Sq. Ft.: Building S�� Description: The undersigned states the following: I am a Florida registered professional engineer or architect with an active license. On a C75 heo 2 r , 20A_, I inspected the parking lots servicing the above referenced building for compliance with Section 8C-6 and determined the following Icheck only one): The parking lot(s) is not adjacent to or abutting a canal, lake or other body of water. r— The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. r The parking lot(s) is adjacent to or abutting a canal, lake or other body of water and parked vehicles are not protected by a guardrail that complies with Section 8C-6 of the Miami -Dade County Code. I have advised the property owner that he/she must obtain a permit for the installation of the guardrail and obtain all required inspection approvals to avoid enforcement action. A I" (-, Signature and Val 1 0 �711t of Architect or E gineer * s� '?Q LIC %r No (Print Nam � 38SS3 � �O ST • �' i •'' ..tz ATF OF ��5�/•.lpRIDA . �''0 VAL EN�?��`�•