Loading...
PLC-14-1778Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-220153 Scheduled Inspection Date: October 28, 2014 Inspector: Diaz, Osvaldo Owner: TERR. LLC, BISCAYNE Job Address: 8851 BISCAYNE Boulevard Miami Shores, FL Project: <NONE> Contractor: DEL RIO & SON PLUMBING CORP Building Department Comments CHANGE GAS WATER HEATER Permit Number: PLC -8-14-1778 Permit Type: Plumbing - Commercial Inspection Type: Final Work Classification: Repair Phone Number Parcel Number 1132060120020 Phone: (786)295-0098 mtractio eassea Loomments INSPECTOR COMMENTS False Inspector Comments PassedEl CREATED AS REINSPECTION FOR INSP-217933. Partial unit ok need to add vacuum breaker for bottom fed water heater 1404M003459 390000BTUs Failed CV Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. October 27, 2014 For Inspections please call: (305)762-4949 Page 13 of 35 BUILDING PERMIT APPLICATION Miami Shores Village P- - -- _ 1 �� T Building Department Au 014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 BY - --� INSPECTION UNE PHONE NUMBER: (305) 762-4949 a, 1 FBC20° Master Permit No:. Sub Permit No. ❑BUILDING ❑ ELECTRIC ❑ ROOFING ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL [:]PUBLICWORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: /5 C• '? Y 110�/ E F L V p Folio/Parcel#: L. Q a 0 Is the Building Historically Designated: Yes NO X Occupancy Type: un y�� Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simp TitlehollId''er): � 'N' k-' L_J_C Phone#: DQ5 - ,2-0- ffiVil Address: ) �l �) i�I� j .� t C@( 1 l�� LA- A4= a --O -- City: State: -L_�c rlcf (D Zip: Tenant/Lessee Name: -4" 09 k- ° e- Phone#: _19%'4-+ 60 Email: 4� c CONTRACTOR: Company Name: �� a Phone#: t o L J o Address: .Q CD _ \ (00 City: Qualifier Name: \ZjCLT__x C, C=k�: ® 'k c- � _rnone State Certification or Registration #: <_'' --C � 4 n - `' 2 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Zip: (0 '�_ 725 O q b Address City: State: Value of Work for this Permit: $ a t 9 Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ Newepair/Replace Description of Work: Zip: ❑ Demolition Specify color o(f�color thru tile: Submittal Fee $ �� '�� . Permit Fee $ ( l / 5 CCF $�I� CO/CC $ Scanning Fee $ Radon Fee $ F�,; DBPR $ Notary Technology Fee $ �� + g/ r),' �� �') Trainin Education Fee $ �4 Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $� (Revised02/24/2014) . . q L Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be ipproved and a reinspection fee will be charged. OWNER or AGENT The foregoing instrument was acknowledged before me this day of 20 by tiLo_roli A L.�'� . who is personally known to me or who has produced as identification and who did take an oath. Signature "S'�"Q CONTRACTOR The foregoing instrument was acknowledged before me this day ofV 1 .20 . by l_i ci is known to me or who has produced (- (_;)(2JV1UL-- as Identification and who did take an oath. NOTARY PUBLIC: NOTARY PUBLIC: Sign: Sign: �- x Print• a _c) Print: Cn - r te Seal: °`�� Seal: =d`�` !NY CO FF124989 E)MR6: MAY 20,2018 /J/�����ihN Bonded through 1st $to Insumm �r i I i � � ����`��\\\• ************************************************************************************************************ APPROVED BY ( �� % ��% `j Plans Examiner Structural Review (Revised02/24/2014) Zoning Clerk Detail by Entity Name Florida Limited Liability Company LFNG LLC Filing Information Document Number L14000008648 FEI/EIN Number NONE Date Filed 01/16/2014 State FL Status ACTIVE Effective Date 01/15/2014 Principal Address C/O CJLAW 1395 BRICKELL AVE. #800 MIAMI, FL 33131 Mailing Address C/O CJLAW 1395 BRICKELL AVE. #800 MIAMI, FL 33131 Registered Agent Name & Address MARILI CANCIO JOHNSON PA 139 BRICKELL AVE #800 MIAMI, FL 33131 Authorized Person(s) Detail Name & Address Title AR MARILI CANCIO JOHNSON PA 1395 BRICKELL AVENUE #800 MIAMI, FL 33131 No Annual Reports Filed 01/16/2014 -- Florida Limited Liability I View image in PDF for Page 1 of 2 http://search. sunbiz. org/InquirylCorporationSearchIS earchResultDetaillEntityName/flal-11... 8/14/2014 Sep 1614 09;57p 0STATE OF FLORIDA 2�: DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CFC 1427 828 ISSUED: 06/23/2014 CERTIFIED PLUMBING CONTRACTOR DEL RIO, EDELBERTO DEL RIO & SON'PLUMBING CORP IS CERTIFIED under the PfavfslOns of Ch,489 FS. EVL*aW- dale : AUG 31, :file L14=3a=538 7863625426 p.1 1 •4 Dimensions and Specifications: INDUCED RAFT MOTOR I- NPT 1 -NPT RELIEF RELIEF FOR EASE IN ORDERING VALVE VALVENG BY MODEL NUMBER Q OPENING Q OPENI \ ` CG o�N 180 080 OUTLET OUTLET This is a natwal gas Charger water heater. It has standard construction, C A A 180,000 Btu/hr, and 81 gallon INLET INLET storage capacity. 71 N'T E Wul SEP 152014 GAS CONNECTION I �' B��cE GAS CONNECTIOT1 �NOE MODELS CG120-400 MODEL CG -500-:- - Model Btu/hr Cupadty GPH @ Vent Gas Water Shipping Number Input Gallons 100*F Rise A B C i E Size —Conn Conn Weight (GN120070 120,000 71 116 69-3/4" 27-3/4" 52" 19-3/4" 4-1/4" 6" 1/2" 1-1/2" 400 (GN150032 150,000 32 145 45" 27-3/4" 42-1/2" 15-3/4" 5" 6" 3/4" 1-1/2" 460 (611155 000 154,000 81 149 73" 27-3/4" 59" 19-3/4" 4-1/4" 6" 1/2" 1-1/2" 470 CGN180 080 180,000 81 175 67-1/2" 27-3/4" 54-3/4" 20-1/2" 4.1/2" 6" 1/2" 1-1/2" 470 CGN200 032 199,000 32 194 45" 27-3/4" 42-1/2" 15-3/4" 5" 6" 3/4" 1-1/2" 460 CGN200080 199,000 81 193 67-1/2" 27-3/4" 543/4" 20.1/2" 4-1/2" 6" 1/2" 1-1/2" 470 CGN200100 199,000 100 193 75" 27-3/4" 62-3/4" 20-1/2" 41/2" 6" 1/2" 1-1/2" 603 (611199100 (A) 199,000 100 193 72" 30-1/4" 56-1/2" 19-3/4" 41/2" b" 1/2" 2" 630 CGN250100 (A) 250,000 100 242 72" 30-1/4" 56-1/2" 19-3/4" 41/2" 8" 1/2" 2" 630 CGN250065(A) 251,000 65 243 75" 27-3/4" 58-3/4" 20" 41/2" 8" 1/2" 1-1/2" 750 (611275 100 (A) 275,000 100 267 72" 30-1/4" 56-1/2" 19-3/4" 41/2" 8" 1/2" Zn 630 (611305 065 (A) 305,000 65 296 75" 27-3/4" 58-3/4" 20" 41/2" 8" 1/2" 11/2" 750 R3365A85-(A� 365000 85 354 79-1/2" 27-3/4" 63" 22-1/2" 41/2" 8" 3/4" 1-1/2" 725 (Al 39 CG1500 085 M) 501C0OT� 85 485 82-1/4" 27-3 4" 65-3j4"_2r1/2" 41 2" 8" 1" =—�4gAconn for dimensional information on Top and Back Tappings Standard Features: Optional Equipment: • 80% Thermal Efficiency • UL Sanitation • Multi -Flue Design • High Altitude (2,000 to 8,000 feet) • Glass Lined Tank • 150 PSI Working Pressure • Tank Saver Anode • • • • ... • ASME Temperature & Pressure Relief Valve • • • • Automatic Reset High Limit. • • • • • • • • • • • • • ...... ... • Spark Ignition • • ...... ...... • 180°F Operation Approved 0000 . • • • Combustible Floor Approved 989669 • • • • • • • •"' • Steel Jacket with Foam Insulation.. • • • "' • • 0 • . . • Hand Hole Cleanout go • .. • • • ' • • • : • • Slide Out Burner Tray :00:0: • •. • 3 Year Limited Warranty on Tank • • • • • • • • 1 Year Limited Warranty on Parts • • • •""• V $Xk0 joumd �� emlPoolHeeteis AN i SF -5 M E M B E R B1gL E�denry Weser Heaters, Hollers S M Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090. 615-889-8900 / Fax: 615-547-1000 www.Lochinvor.com CGR-17 (Revised CGR-17 10/11) PDP -W -1/12 -Printed in U.S.A. Dependable, Tank Type Charger The Lochinvar Charger gas fired, tank type water heaters are designed to provide ease of installation, low stand-by loss and years of trouble free service. Chargers are ideally suited for apartments, schools, food service and many other commercial and industrial applications with requirements for hot water. They are built to ensure easy installation and maintenance. Outstanding Features / Quality Design The Charger features a multi -flue design for increased efficiency and fast heat transfer. The tank is glass lined for prolonged life and protection from rust and corrosion. The tank is certified for 150 psi working pressure and is available in standard construction or ASME construction (over 200,000 Btu/hr input). Multiple anode rods are installed for additional protection from corrosion. Factory installed, motorized flue dampers hold in heat during the off cycle. Ease of Installation Charger installations are fast and easy. The water heaters are fully assembled and ready to drop into any applications. The Charger has a small footprint and is often shorter than competitor models. The Charger is designed with three sets of water circulation tappings. Water connections on the top, the front and the back provide ultimate flexibility, especially on retrofit applications. Even More to Offer All Chargers feature spark ignition which is more efficient than traditional standing pilots. Hand hole cleanouts and slide out burner trays offer superior serviceability. And all models are combustible floor approved. Meets ASHNE Energy Efficiency Standards • • 00 . • 0000 . . • 000000•... •••64 • 0000..•. • 0000•• . • 0000.... • 0000•• • ...0000. • 00.00 0000 0000 •• • .6460•. • • • • 0000•... • • 0000 • 00.00• • 0080 0000...• • • 0000.•.• 0000.••. 0000.•. 0000.•• 0000••.• • 0000.... 0000•••• • BILL.' TO STEINE ATLANTIC CORS P.O. BOX 380578 • MIAMI, FLORIDA 33238-0578 DADE: (305) 754.4551 • TOLL FREE: 1-800-333-8883 • FAX: (305) 751-8390 www.steineratiantic.com DREAM COIN LAUNDRY 8851 BISCAYNE BOULEVARD MIAMI. FL 33138 OFFICE AND SHOWROOM 290 N.E. 68th STREET MIAMI, FLORIDA 33138-5520 FOB: ORIGIN SHIP' TO DREAM COIN LAUNDRY 8851 BISCAYNE BOULEVARD MIAMI FL 33138 OUR TRUCK, STOCK NO. DESCRIRTIOf `: UIM QUANTITY UNit' RICE AII80q1TC _OC CGN400--100 LOCi-3INVAR 100 GAL WATER HEA TEA I 8525.L"2100 8525.00 NATURAL GAS, 39, 000OBTU Serial Numb6r .- 1404M00345 wp Subtotal 8525.00 INLAND FREIGHT 300.00 DELIVERY—OUR Tt?UC{' OLS 300.00 Sales Tai 579.50 Total 9704.50 Deposits Applied 3722s50CR Credit on Account 18.00CR •••• Gao• • •r9••• • • • •• •• • • 0000 • 0'000•• 0000 ••9.9• g*:6 0.0090 90090• . I 'w9••• • 9•••9• •+••s •••9 • 0 • 000090 so g0000 ' • 0 009000 09099• • • - ... • • ••••t•. • • • • •go •99.9• • 00.0 nILL GOODS SOLD ARE F. iso B. ORIGIN. -JE APPRECIATE )OUR BUSINESS! "PURCHASER REPRESENTS THAT PURCHASER HAS READ AND ACCEPTS WITHOUT QUALIFICATION ALL OF THE TERMS AND CONDITIONS OF SALE INCLUDING THOSE LISTED ON THE REVERSE SIDE HEREOF."