DS-13-1408 (4)Inspection Worksheet
Miami Shores Village
10050 N.E. 2nd Avenue Miami Shores, FL
Phone: (305)795-2204 Fax: (305)756-8972
Inspection Number: INSP-194049 Permit Number: DS -6-13-1408
Inspection Date: July 22, 2014 Permit Type: Driveways/Sidewalks/Slabs
Inspector: Rodriguez, Jorge
Inspection Type: Final
Owner: MORGAN, MARY Work Classification: New
Job Address: 307 NE 95 Street
Miami Shores, FL 33138 -
Phone Number (305)606-2098
Parcel Number 1132060136000
Project: <NONE>
Contractor: MIAMICRETE INC Phone: (305)790-4850
Buildina Department Comments
INSTALLATION OF NEW WALKWAYS AROUND
Infractio Passed comments
INSPECTOR COMMENTS False
PROPERTY
Inspector Comments
Passed
Failed
Correction
Needed
❑
Re -Inspection ❑
Fee
No Additional Inspections can be scheduled until
re -inspection fee is paid.
For Inspections please call: (305)762-4949
July 21, 2014 Page 1 of 1
AL ITTIAL M
.AFAWMNA�
DYNATECH ENGINEERING CORP.
Miami, May 28, 2014
Mr. Enrique Nuflez
MIAMICRETE, INC.
7910 SW 16"' Street
Miami, FL 33155
Re: Proposed Walkway @
307 NE 95th Street
Miami, FL
Dear Mr. Nuftez:
MATERIAL TESTING
DRILLING SERVICES
INSPECTION SERVICES
ROOF TESTING
Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on
May 28, 2014 at the above referenced project. DEC was authorized to perform a compaction test
only. The purpose of our test was to determine the degree of compaction of the tested layer of
material only. In no way shall a compaction test replace a demucking inspection, soil bearing
capacity determination, or a pad certification. A soil boring test must be performed by client if
not yet done, prior to construction to verify subsoil conditions. Underlying soils below test
levels must be verified to prevent future settlements. (DEC) was not authorized to perform
supervision and certification of the building pad preparation. This is not a pad certification.
Our findings are relative to the date and areas of our site work and should not be relied upon to
represent conditions on other areas or dates. Any subsequent site disturbances due to water
erosion, rain, storm gutters discharging at footings, construction activities, excavations,
overgrown, vegetation, traffic and other disturbances will void this test and the site must be re -
compacted and re -tested prior to construction.
Environmental analysis of the soil materials is not part of the scope of services. If environmental
analysis of the soils is required, we can provide a proposal for performing an environmental
analysis of the soil materials. No other analysis is implied or warranted.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the
confidential property of clients, and authorization for use, publication of statements, conclusions
or extracts from or regarding our reports is reserved pending our written approval.
Enclosed find copies of the compaction test results. It has been a pleasure working with you and
look forward to do so in the near future.
Sincerely yours,
Wissar Naamani, P.E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Special Inspector No. 757
Cst°�4��;cFL�(�618
8410
®J9584
®® Sr4TF
ZO
110
Phone: (305) 828-749A Na4xa) 828-9598
E -Mail: Dynatech@bellsouth.net
DYNATECH
ENGINEERING CORP.
750 WEST 84TH STREET
HIALEAH, FLORIDA 33014
(305) 828-7499
MOISTURE -DENSITY RELATIONS OF SOILS
PROCTOR COMPACTION TEST
DATE: May 28, 2014
CLIENT: MIAMICRETE, INC.
PROJECT: Proposed Walkway Q
ADDRESS: 307 N. E. 95" Street, Miami, FL
CONTRACTOR: Miamicrete, Inc.
MATERIAL DESCRIPTION: Gray sand
SAMPLED BY: RN
TEST RESULTS
Sample Number 1
TESTED BY: RN
The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a
10 lb. Hammer and an 18" drop ASTM D-1557.
% MOISTURE
6.6
6.9
7.8
12.1
DRY DENSITY
104.1
105.0
106.0
103.8
Optimum Moisture 8.2 Percent
100% Maximum Dry Density 106.4 lbs./cu.ft.
% Passing 3/4" Sieve 88 Percent
108
106
104
102
100
Sampled By: RN ®®®®\\ 1 I I 1 I d /////,98
Tested By: RN ®®®tj PAso
Checked By: WN ®®®® ',;;A,
5 'Z.
As a mutual protection to clients, the public and ourselve 11 repbai C
are submitted as the confidential property of clients, and a—'rbrization
for use, publication of statements, conclusions or extracts ontpr regarhii'ig
our reports is reserved pending our written approval.
R®FESSe®
1/
10 12 14
Respectively submitted,
Z
tssam N i, P.E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Certificate of Authorization No.: CA 5491
D
R
Y
D
E
N
S
I
T
Y
DYNATECH ENGINEERING CORP.
TEST NO.
1
750 WEST 84' STREET
3
4
HIALEAH, FLORIDA 33014
DEPTH
12"
(305) 828-7499
12"
FIELD DENSITY TEST OF COMPACTED SOILS
DATE:
May 28, 2014
104.4
CLIENT:
MIAMICRETE, INC.
105.3
PROJECT:
Proposed Walkway�a,
6,7
ADDRESS:
307 N. E. 95th Street, Miami,
FL
CONTRACTOR: Miamicrete, Inc.
MAX. DENSITY IN THE FIELD %
Test No. 1
Location: South side of walkway,
center of pad underslab
Test No. 2
Location: West side of walkway,
center of pad underslab
Test No. 3
Location: North west side of walkway, center of pad underslab
Test No. 4
Location: North side of walkway,
center of pad underslab
Test No. 5
Location: North side of walkway,
west side of pad underslab
Description of Material: Gray sand
1 106.4
TEST NO.
1
2
3
4
5
DEPTH
12"
12"
12"
12"
12"
FIELD DENSITY
104.4
104.9
104.5
105.3
105.1
MOISTURE CONTENT %
6,7
7,0
6,8
6,5
7,1
MAX. DENSITY IN THE FIELD %
98,1
98,5
98.5
98.9
98.7
COMPACTION REQUIREMENTS
% OF MAXIMUM DENSITY
98%
98%
98%
98%
98%
100% MAXIMUM DENSITY (LAB)
106.4
1 106.4
1 106.4
1 106.4
1 106.4
REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REOUIREMENTS
Respectfully submitted,
Sampled By: RN
Tested By: RN
Checked By: WN is aamani, P.E.
'aybiA'J CH ENGINEERING CORP.
Flor}� No. 39584
Certr�f Authorization No.: CA 5491
o �® 0k e =
*A density test determines the degree of compaction of the wo dr of material : In ne- jo! �l a density test replace a soil bearing capacity determination.
A soil boring test must be provided by client, prior to consti0di n to verify s4oil co 6 4 a mutual protection to the clients, the public and ourselves, all
reports are submitted as the confidential property of clients, au* oration fore o cation S�c�atement conclusions or extracts from or regarding our reports is
reserved pending on our written approval.
"//;,"�0FESM(
1110,
EMILIANO OROZCO, P.E.
FL. P.E. No. 66341
817 SW 122 Ave
Miami, Fl. 33175
Tel. (786) 355-2788
Miami Shores Village
Building Department
10050 NE 2nd Avenue.
Miami Shores, Fl. 33138
Address: 307 NE 95 St. Miami Shores, Fl. 33138
Folio Number: 11-3206-013-6000
SOIL COMPACTION LETTER
Gentlemen:
April 8, 2014
'0''
This is to inform you that I, personally made a field inspection of the fill under the slab
and could observe that it had a more than adequate degree of compaction, at least 95 % of
the Proctor Test
If you have any additional questions; or need additional information; please do not
hesitate to contact me at the above mentioned phone number.
Very truly yours;
<-- 511 CT" � -
Emilian OrOzCw
P.E. #66341
GEOTECHNICAL
ENVIRONMENTAL
HYDROGEOLOGY
ASBESTOS
MY—
DYNATECH ENGINEERING CORP.
Miami, May 28, 2014
Mr. Enrique Nunez
MIAMICRETE, INC.
7910 SW 16" Street
Miami, FL 33155
Re: Proposed Walkway @
307 NE 95u' Street
Miami, FL
Dear Mr. Nunez:
MATERIAL TESTING
DRILLING SERVICES
INSPECTION SERVICES
ROOF TESTING
Pursuant to your request, Dynatech Engineering Corp. (DEC) performed a Compaction Test on
May 28, 2014 at the above referenced project. DEC was authorized to perform a compaction test
only. The purpose of our test was to determine the degree of compaction of the tested layer of
material only. In no way shall a compaction test replace a demucking inspection, soil bearing
capacity determination, or a pad certification. A soil boring test must be performed by client if
not yet done, prior to construction to verify subsoil conditions. Underlying soils below test
levels must be verified to prevent future settlements. (DEC) was not authorized to perform
supervision and certification of the building pad preparation. This is not a pad certification.
Our findings are relative to the date and areas of our site work and should not be relied upon to
represent conditions on other areas or dates. Any subsequent site disturbances due to water
erosion, rain, storm gutters discharging at footings, construction activities, excavations,
overgrown, vegetation, traffic and other disturbances will void this test and the site must be re -
compacted and re -tested prior to construction.
Environmental analysis of the soil materials is not part of the scope of services. If environmental
analysis of the soils is required, we can provide a proposal for performing an environmental
analysis of the soil materials. No other analysis is implied or warranted.
As a mutual protection to clients, the public and ourselves, all reports are submitted as the
confidential property of clients, and authorization for use, publication of statements, conclusions
or extracts from or regarding our reports is reserved pending our written approval.
Enclosed find copies of the compaction test results. It has been a pleasure working with you and
look forward to do so in the near future.
Sincerely yours,
WissanfNaamani, P.E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Special Inspector No. 757
Ct44*%441kftN,TLOA(1618
QpO. SA40
No. 3�
O ; Sr4r
:.n F Op
If
Phone: (305) 828-749�Oj� RI® , ��9598
E -Mail: Dynatech@bellsouth.net
Q0 AMNe -ft.,"P%-
DYNATECH
ENGINEERING CORP.
750 WEST 84H STREET
HIALEAH, FLORIDA 33014
(305) 828-7499
MOISTURE -DENSITY RELATIONS OF SOILS
PROCTOR COMPACTION TEST
DATE: May 28, 2014
CLIENT: MIAMICRETE, INC.
PROJECT: Proposed Walkway (a,
ADDRESS: 307 N. E. 95t" Street, Miami, FL
CONTRACTOR: Miamicrete, Inc.
MATERIAL DESCRIPTION: Gray sand
SAMPLED BY: RN
TEST RESULTS
Sample Number 1
TESTED BY: RN
The following compaction test was conducted in accordance with the Standard Methods for Moisture Density Relations of soil using a
10 lb. Hammer and an 18" drop ASTM D-1557.
% MOISTURE
6.6
6.9
7.8
12.1
DRY DENSITY
104.1
105.0
106.0
103.8
Optimum Moisture 8.2 Percent
100% Maximum Dry Density106.4 lbs./cu.ft.
% Passing 3/e" Sieve 88 Percent
Sampled By: RN
108
106
104
102
100
98
Tested By. RN r
Checked By: WN
As a mutual protection to clients, the public and ourselviiila940
10b,;
are submitted as the confidential property of clients, an ration
for use, publication of statements, conclusions or extracts�rq�► or reWding'p O�
our reports is reserved pending our written approval. Z��
` 0.
�/ a
SRO F E S S�®��
�
10 12 14
Respectively submitted,
1'
issam N , P.E.
DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Certificate of Authorization No.: CA 5491
D
R
Y
D
E
N
S
I
T
Y
DYNATECH
ENGINEERING CORP.
750 WEST 84' STREET
HIALEAH, FLORIDA 33014
(305) 828-7499
FIELD DENSITY TEST OF COMPACTED SOILS
DATE: May 28, 2014
CLIENT: MIAMICRETE, INC.
PROJECT: Proposed Walkway @
ADDRESS: 307 N. E. 95th Street, Miami, FL
CONTRACTOR: Miamicrete, Inc.
Test No. 1 Location: South side of walkway, center of pad underslab
Test No. 2 Location: West side of walkway, center of pad underslab
Test No. 3 Location: North west side of walkway, center of pad underslab
Test No. 4 Location: North side of walkway, center of pad underslab
Test No. 5 Location: North side of walkway, west side of pad underslab
Description of Material: QM sand
TEST NO.
1
2
3
4
5
DEPTH
12"
12"
12"
12"
12"
FIELD DENSITY
104.4
104.9
104.5
105.3
105.1
MOISTURE CONTENT %
6,7
7,0
6,8
6,5
7,1
MAX. DENSITY IN THE FIELD %
98,1
98,5
98,5
98,9
98,7
COMPACTION REQUIREMENTS
% OF MAXIMUM DENSITY
98%
98%
98%
98%
98%
100% MAXIMUM DENSITY (LAB)
106.4
106.4
106.4
106.4
106.4
REMARKS: ALL ABOVE TEST RESULTS COMPLY WITH COMPACTION REQUIREMENTS
Respectfully submitted,
Sampled By: RN
Tested By: RN', �/`
Checked By: WN �e® ��
tss aamani, P.E.
�`_� ,•�fc �'':�d,�� DYNATECH ENGINEERING CORP.
Florida Reg. No. 39584
Certificate of Authorization No.: CA 5491
��,' r! s _
'A density test determines the degree of compA� ofthe teste er o ! ly. In no way shall a density test replace a soil bearing capacity determination.
A soil boring test must be provided by client, }ifo o to cons on t* -illy ` it conditions. As a mutual protection to the clients, the public and ourselves, all
reports are submitted as the confidential property of glients, and;an,`for publication of statement conclusions or extracts from or regarding our reports is
®t reserved pending on our written approval.
'mss -%,)1-/(° ?-
Notice of Preventative Treatments for Termites
(As required by Florida Building Code (FBC) 104.2.6)
J&A Tenting Corp
7109 SW 44 St. Miami, Fl. 33155
305-6678911
Permit #
307 NE 956 ST. MIAMI SHORE, FL. 33138
06-04-14
Date
CYPER TC
Product Used
25%
Percent Concentration
Address or Treatment or Lot/Block of Treatment
Time
CYPERIVIETHRIN
Chemical Used (active ingredient)
60
Area Treated (Square feet)
JUAN NUNEZ
Applicator
6
Number of gallons applied
Linear feet treated
HORIZONTAL
Stage of treatment (Horizontal, Vertical, Adjoining Slab, retreat of disturbed area)
As per 104.2.6 — if soil chemical barrier method for termite prevention is used, final exterior
treatment shall be completed prior to final building approval.
If this notice is for the final exterior treatment, initial and date this line
A o ' d Signature11-1