Loading...
ACT-13-1741Miami Shores Village _ Building Department A IA U 3 L�1 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 , Tel: (305) 795.2204 Fax: (305) 756.8972 INSPEC"l ION'S PHONE NUMBER: (305) 762.4949 FBC 20 BUILDING� Permit No. ` L� � PERMIT APPLICATION Master Permit No. Permit Type: BUILDING ROOFING JOB ADDRESS. 361 NE 102 ST. City: Miami Shores County: Miami Dade Zip: 33138 Folio/Parcel# Is the Building Historically Designated: Yes NO X Flood Zone: OWNER: Name (Fee Simple Titleholder): Connie Benson Phone#: 305 790-3069 Address: 361 NE 102 ST. City: Miami Shores TenantlUssee Name: N/A Email: NIA State. FL. Zip: 33138 CONTRACTOR: Company Name. Jorge Enterprises Inc. phone# 305 525-7824 Address: 5990 SW 22 ST. City. Miami State: FL. gip. 33155 Qualifier Name: Gonzalo Jorge phones 305 525-7824 State Certification or Registration #: CGC1512265 Certificate of Competency #: Contact Phone# 305 525-7824 Email Address: gojorgenow@yahoo.com DESIGNER: Architect/Engineer. I Engineer PLLC phonet 954 2742429 Value of Work for this Permit: $ 750 SquarejUnear Footage of Work.. 40 SQ. Ft Type of Work: OAddition OAlteralion ONew ORepair/Replace ODemolition Description of Work: Canvas Awning Canopies over Front & Side Door Color thm tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Educatiou Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ I Bonding Company's Name (if applicable) N/A Bonding Company's Address City State Mortgage Lender's Name (if applicable) N/A Mortgage Lender's Address City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR BIPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued In the. of such posted notice, the inspection will not be approved and a reinspection fee will be charged Signature Own Agent The foregoing instrument was acknowledged ore me this day of 20®/ , by who itsnaIIyImo wn or who has produced M As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: ,/ Contractor The foregoing )"eat was acknowledged before me this dl!" day of ��t 20 l�by who is person kno to me or who has produced as identification and who did take an oath. aat;: ;moo COWAO JORGE My Commission Expires: * COMMISSION g 035417 EXPIRES: February 16, 2015 �4�C;Wdi' Bonded Tree Bu* Ndhw Sr" APPROVED BY �) Plans Examiner 7l � Structural Review (Revised 3/12=2)(Revised 07/10/07)0tevlsed 06/10=W)(Revised 3/15/09) NOTARY PUBLIC: Sign: My v Public - staw et.flwaa :6omm. Expiroa Oet 26; 2014 Commission iv EE 38220 96nW'Throu9h National Notary Assn Zoning Clerk 1141 FD, 1/2- IRON cv _ w PIPE — NO CAP oLr) ASPHALT a, o 15 FT. -'ALLEY M 89'16 01 ''`" E -125.00'(R & M 0.4 4 FT. L. FENCE .n S. C. S. c.i �. 19. \� a A/C B.S. �WALL ® N SLAB 56.15' 12.2' 0 0-9'\\ELECT.' METER CV CO C. ' k SL Buj ci W °° • U N u r o o u o wIS J (n J 2.0 2:0 O w in U � 56.60' 0 Lar 3 /�l%n%Sh�RC 4-: L� d' 0.2' FD. DRILL HOLE IN CONC. WALK a, U') 5 ®wrr- .� N 00 N n N 5a1=T. t'O,�IG°:.. S1[sIh1A°K.� , . aa• a ' p . S !�901100'0 5.00' FD. 1/2- IRO CONC. NO CAP ASPHALT DRIVE N. E. 102ND S T 75 FT R/W Trdifirate of Ntamr TArst'staurit STEip REGISTERED ISSUED BY APPLICATION HER MUTE PRODUCTS VVC Date Work Performed CONCERN NO. PO BOX 435 EMIGSVILLE PA 17318 2/20/2013 �F El F-06901 This is to certify that the materials described below have been flame-retardant treated (or are inherently nonflammable). FOR TRI VANTAGE LLC AT 1831 NORTH PARK AVENUE CITY GLEN RAVEN . STATE NORTH CAROLINA 27217-1100 Certification is hereby made that: (Check "a" or "b") (a) The articles described at the bottom of this Certificate have been treated with a flame retardant chemical ❑ approved and registered by the State Fire Marshal and that the application of said chemical was done in conformance with the law of the State of California and the Rules and Regulations of the State Fire Marshal. Name of chemical used Method of application Chem. Reg. No, x (b) The articles described at the bottom hereof are made from a flame -resistant fabric or material registered and approved by the State Fire Marshal for such use. Trade name of flame -resistant fabric or material used REINFRCD VINYL Reg. No. F-06901 The Flame -Retardant Process Used WILL NOT Be Removed By Washing PETER COHEN Name ofApplicator or Production Superintendent By STEPHANIE MUMMERT, Q C MANAGER Title We hereby certify this to be a true copy of the original "CERTIFICATE OF FLAME RESISTANCE" issued to us, "original copv" of which has been filed with the California State Fire Marshal. Customer PO# Gonzalo Invoice Number 40574923 Quantity .250 YD WEBLON CP2739-62 Description IVORY COAST Product Code 857239 JORGE ENTERPRISES, INC. 5990 SW 22ND STREET MIAMI FL 33155 TRI VANTAGE, LLC By I Control/Lot # .[ Control/Lot # I 48032H2134 STATE OF (FLORIDA) COUNTY OF (DADE) Miami Shores Village Building Department SURVEY AFFIDAVIT 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 The undersigned Affiant, Connie Benson , does hereby attest that (Property owner) The attached survey, performed by J.H. Manucy, Inc. (Name of surveyor's company) For address: 361 NE 102nd Street, Miami Shores, FL 33138' Performed on 9/22/05 (date of survey) is an accurate representation of the existing conditions and locations of all structures on the property as of this date. The purpose of this Affidavit is to induce Miami Shores Village to issue a building permit for the property without first providing a survey less than seven (7) years old old. The Affiant, as property owner, further agrees to remove or obtain permits for any structures which now may exist on the property which are not permitted or which may violate zoning or building code regulations. The Affiant further understands that the existence of any such structures may affect final inspections as applicable to this or other permits. Further, 'rant say eth naught Connie Benson Property Owner Signature vroperry uwner rnnt Name SWORN TO AND SUBSCRIBED before me this c-�V day of d1tv" ey . Affiant is personally known to me, produced • e0NULOJOq(,1E MYCOMMISSMN#EOMI o� Q Revised on 5/22/2009/ Revised on 8/12109 ��or Fr�``o EXPIRES �6,�ruary 162015 k" Tin k,*Now Serra as identification_ !Engineer, PLLC. Consulting Engineers. 9920 NW 44TH TER #306 DORAL FL 33178 Phone (954) 274-2429; Fax (786) 545-7636 Web site: www.iengineerplic.com; E-mail: ivan@ien igineeipllc.com PAGE i/20 COVER SHEET DATE: July 22, 2013 PROJECT: Benson Residence AWNINGS ADDRESS: 361 NE 102nd St, Miami Shores, FL 33138 CLIENT: Jorge Enterprises Inc. 5990 Sw 22nd St Miami, FL 33155 gojorgenow@yahoo.com 315 525-7824 This computation book contains manual and computerized structural calculations, certain printed manufacturer's data and Computation pages are numbered 1 thru 20. Computations were performed to the best of our knowledge according to sound and generally accepted engineering principals and Code requirements, using nationally recognized computer software and In-house developed software. Prior to commissioning Into service, the in-house developed software was thoroughly checked by performing parallel manual computations. The sign and seal provided herein are meant to cover all computation sheets pages 1 through 20. F Z1,I/t3 !Engineer PLLC,#29119 Juan C. Moreno, F.L Reg. P. # 69818 VALID ONLY FOR ONE (1) PERMIT ONLY. VALID ONLY WITH RAISED PE SEAL. -ANY CORRECTIONS, INK MARKS, WHITE OUT OR STICK -ONS WILL VOID THESE DRAWINGS AND CALCULATIONS. !Engineer, PLLC. Consulting Engineers. 9920 NW 44T" TER #306 DORAL FL 33178 Phone (954) 274-2429; Fax (786) 545-7636 Web site: www.iengineerpllc.com; E-mail: ivan@iengineerpllc.com PAGE V20 INDEX DESCRIPTION PAGE Wind Loads Calculations. 1 General Sketch 5 Frame with Length and dead load (self weight) 6 Wind Loads 7 Unity check design 9 Elements' design 10 Load reactions 11 Wall anchor bolt design detail "b" 15 1/20 MECAWind Version 2.1.0.6 per ASCE 7-10 Developed by MECA Enterprises, Inc. Copyright 2013 www.mecaenterprises.com Date : 7/22/2013 Project No. Company Name : Designed By Address Description City Customer Name State Proj Location File Location: C:\Documents and Settings\JUAN M\My Documents\JOBS\AWNINGS 1\JORGE ENTERPRISES\361 NE 102nd St, Miami Shores, FL 33138\awning monoslope enclosed LRFD.wnd Directional Procedure All Heights Building (Ch 27 Part 1) All pressures shown are based upon STRENGTH Design, with a Load Factor of 1 Basic Wind Speed(V) = 105.00 mph Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor = 0.85 Damping Ratio (beta) 0.01 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 4.5 : 12 Slope of Roof(Theta) = 20.56 Deg Ht: Mean Roof Ht = 8.25 ft Type of Roof = Monoslope RHt: Ridge Ht = 9.00 ft. Eht: Eave Height = 7.50 ft OH: Roof Overhang at Eave= .00 ft Roof Area 26.00 ft/' 2 Bldg Length Along Ridge = 6.00 ft Bldg Width Across Ridge= 4.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc*(33/Zm)^0.167 = 0.23 Lzm: 1*(Zm/33)^Epsilon = 427.06 ft Q: (1/(1+0.63*((B+Ht)/Lzm)^0.63))^0.5 = 0.97 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.91 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure.Coefficient = +/-0.18 Figure 27.4-1 External Pressure Coefficients Cp - Loads on Main Wind -Force Resisting Systems 2/20 L P B Kh: 2.01*(Ht/Zg)^(2/Alpha) = 0.85 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256*(V)112*I*Kh*Kht*Kd = 20.37 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 26.00 ft^2 Reduction Factor based on Roof Area = 1.00 MFRS -Wall Pressures for Wind Normal to 6 ft wall (Normal to Ridge) wall Cp Pressure Pressure +GCpi (ps£) -GCpi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.50 -12.32 -4.99 Side Walls -0.70 -15.78 -8.45 Wall zlev Kz Kzt qz Press Press Total ft psf +Gepi -Gepi +/-GCpi ---------------- ------ ----- ------------ ------- ------- --------- Windward 9.00 0.85 1.00 20.37 10.18 17.51 22.50 Note: 1) Total = Leeward GCPi + Windward GCPi Roof Location Cp +GCpi(psf)-GCpi(psf) ----------------------- ----------------- ---------- Windward - Min Cp -0.68 -15.44 -8.11 Windward - Max Cp -0.16 -6.44 0.90 Leeward Perp to Ridge -0.60 -14.05 -6.72 Overhang Top (Windward) -0.68 -11.77 -11.77 Overhang Top (Leeward) -0.60 -10.39 -10.39 Overhang (Windward only) 0.80 13.85 13.85 MWFRS-Wall Pressures for Wind Normal to 4 ft wall (Along Ridge) Wall Cp Pressure Pressure +GCpi (psf) -GCPi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.40 -10.59 -3.26 3/20 Side Walls -0.70 -15.78 -8.45 Wall Slav lir. Kzt qz Press Press Total ft Psf +GCPi -GCPi +/-=Pi ---------------- ------ ----- ----- ------- ------- ------- --------- Windward 9.00 0.85 1.00 20.37 10.18 17.51 20.77 Note: 1) Total = Leeward GCPi + Windward GCPi Roof - Dist from Windward Edge CP Pressure Pressure +GCpi(pef)-GCpi(psf) --------------------------------- ------ ---------- ---------- 0.0 ft to 4.1 ft -1.30 -26.17 -18.84 4.1 ft to 6.0 ft -0.70 -15.78 -8.45 -0.70 -15.78 -8.45 4120 MECAWind Version 2.1.0.6 ASCE 7-10 Developed by MECA Enterprises, Inc. Copyright 2013 www.mecaenterprises.com Date 7/22/2013 Project No. Company Name Designed By Address Description City Customer Name State Proj Location : File Location: C:\Documents and Settings\JUAN M\My Documents\JOBS\AWNINGS 1\JORGE ENTERPRISES\361 NE 102nd St, Miami Shores, FL 33138\awning monoslope enclosed LRFD.wnd 'a a Rodnot rd I 1 --- a I 1-` 1 4a3----------- Wags �� a 1lonosloae Roof 10 < 0 <-- 30 Wind Pressure on Components and Cladding (Ch 30 Part 1) A11 pressures shown are based upon STRENGTH Design, with a Load Factor of 1 Width of Pressure Coefficient Zone "a" - 3 ft Description Width Span Area Zone Max Min Max P Min P ft ft ft^2 GCp GCp psf psf ----------------------------------------------------------- �. rafter 3.00 4.00 12.0 1 0.39 -1.28 16.00 -29.82 rafter 3.00 4.00 12.0 2 0.39 -1.57 16.00 -35.6 WIND LOAD GENERAL SKETCH 5120 DEAD LOAD = SELF WEIGHT & MEMBERS' LENGTH 6/20 WIND LOAD (+l) 7/20 WIND LOAD (-l) 8/20 UNITY CHECK DESIGN ELEMENT 9/20 0.3% Design Group Results Design Group: Steel_Beam Z G08 per RISC ASD (2005) Designed As: Pipe 1.315 x 0.065, Material: %SteePASTM A992 Grade 50 Combined Check Member Result Offset Code Unity Details Name Case ft Ref. Check BmZ050-2 D+0.6W A+Y 3.0 F!1 -1b 0.0 OK Lb = 3 It Strona Flexure Check Member Result Offset Demand Mz Capacity Mz Code Unity Details Name Case ft Ib -ft Ib -ft Ref. Check BmZ050-2 D+0.6W *+Y 3.0 -2.7 253.6 F8-1 0.0 OK Lbz = 3 ft, Cb=1 Weak Flexure Check Member Result Offset Demand My Capacity My Code Unity Details Name Case ft Ib -ft Ib -ft Ref. Check BmZ050-2 0.6D+0.6W s+Y 0.0 2.3 253.6 178-1 0.0 OK Lby = 3 ft Strong Shear Check Member Result Offset Demand Vy Capacity Vy Code Unity Details Name Case ft Ib Ib Ref. Check BmZ050-2 D+0.6W i)+Y 0.0 -1347.7 2292.7 G6-1 2b+St.Venant 0.6 OK Weak Shear Check Member Result Offset Demand Vz Capacity Vz Code Unity Details Name Case ft Ib Ib Ref. Check BmZ050-2 0.6D+0.6W »+Y 3.0 1346.5 2292.7 G6-1 2b+St.Venant 0.6 OK 0 0 0.91) + 1.OW (+l) REACTIONS co= - 11/20 0.91) + 1.OW (+l) REACTIONS (members are not showed for clarity) \o 4196Z- = J VV.S- fl 9 61. cu&Z-_: AO 914, A 1+ QI 86Z- Q VI 60- _ QI 99- . 44, 19. 41996-=AA—� o� o� o� 416SZ- _ !l 91 S9- _ Q 12/20 1.2DL + 1.OWL+0.5Lr (-l) REACTIONS 9 13/20 1.2DL + 1.OWL+0.5Lr (-Y) REACTIONS (members are not showed for clarity) 1 ^V 33 Ib ry =104 lb hp\o ^moo FY =130 Y=33 lb 9, ``9" kA - 137 t} 137 IbNFY = 37 lb } �FY = 88 Ib 0 \ =137 Ib ,may 37 Ib A. 14/20 15/20 www.hiltLue Profis Anchor 2A.1 Company: (ENGINEER, PLLC. Page: 1 Specifier. JUAN C. MORENO Project Address: 9920 NW 44TH TER. #306 DORAL FL 33178 Sub -Project I Pos. No.: Phone I Fax 954 274 2429 1 786 545 7636 Date: 2107/2013 E -Mail: juan@iengineerpAccom specifiees comments: 1 Input data Anchor type and diameter. Effective embedment depth: Material: Evaluation Service Report Issued 1 Valid: Proof: Stand-off installation: Anchor plate: Profile: Base material: Reinforcement Seismic toads (cat C, D, E, or F) Geometry On.] & Loading Ob. In.lb] Kwik Bolt 3 - CS 318 (2) • ,� •� h,c = 2,000 in., h,,,,,, = 2,313 in. Carbon Steel ESR -2302 011(r"12101/1=013 design method ACI 318 / AC193 eb = 0,000 in. (no stand-off); t = 0,250 In. k x Ir x t = 2,000 in. x 2,000 in. x 0,250 In.; (Recommended plate thiclumm not calculated) no profile uncradced concrete, 3000, fo = 3000 psi; h = 8,000 in. tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement none or < No. 4 bar no A Anchor bolt z desing detail B it CF) , o _Y--- , , Imnd dam end r�Wm m�ret be checked for egret w"h to Wdso" s MW for cetyl PROFI8 Anoiror (o) 2003.2009 MH AG, FL -94g4 So . Hffd Is a regbWred Tradmomk or M AG. Sdaw x Imnd dam end r�Wm m�ret be checked for egret w"h to Wdso" s MW for cetyl PROFI8 Anoiror (o) 2003.2009 MH AG, FL -94g4 So . Hffd Is a regbWred Tradmomk or M AG. Sdaw 16/20 www.hilti.us Profis anchor 2.4.1 Company: (ENGINEER, PLLC. Page: 2 Specifier. JUAN C. MORENO Project Address: 9920 NW 44TH TER #306 DORAL FL 33176 Sub -Project I Pos. No.: Phone I Fax 954 274 2429 786 545 7636 Date: 22/07/2013 E-Mafl: juart@iengineerpllacom 2 Load case/Resulting anchor forces Load case: Design toads Anchor reactions pbj Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 1554 259 9 25 max concrete compressive strain: 0,61 Jul rrax concrete compressive stress: 268704 resulting tension force In (x/y)=(0,000/0,000): 1554 pbj resulting compression ford In (xty)=(0,864/0,000): 1085 pbj 3 Tension load Load No, [Ib] Capacity.Na pb] Utiliratlon N= N, AN. Status Steel ngth' 554 4 33 OK Pullout Strength' Concrete Breakout Strength" WA N/A WA N/A 1554 2417 65 OK ' anchor having the highest loading "anchor group (anchors in tension) 3.1 Steel Strength N. = ESR value refer to ICC -ES ESR -2302 o Noma N. ACI 318-08 Eq. (D-1) Variables n A.,N pn.1 tuts [psi] 106000 Calculations Nw pb] 6340 - Results Nw (ib) Nw pb] N„g Jib) o 0,750 477 ma dam and m,IIe must be arm for agreernent wfth eye ane wKftmwWfbrp1aLsib 1 PROFIsAndw i c12003.2009 M AG, FL-94943ehaan Hid Is a reyletered TradgMark of HBO AG. schaen 17/20 www.hl tLus input Proft Anchor 2.4.1 Company: IENGINEER, PLLC. Page: 3 Specifier. JUAN C. MORENO Project Address: 9920 NW 44TH TER. #306 DORAL FL 33178 Sub -Project I Pos. No.: Phone I Fax 954 274 2429 [ 786 545 7636 Date: 22/07/2013 E -Mail: Juan@iengineerpllc.com 3.2 Concrete Breakout Strength ANc N°b - \dim) Wed.N WAN Wye N Nb ACI 318-08 Eq. (D -l) � Na, i Nue ACI 318-08 Eq. (D-1) ANO see ACI 318-08, Part D.U.I. Fig. RD.5.2.1(b) ANm = 9 t?,f ACI 318-08 Eq. (D-6) 1 —, WMN = (a' s 1,0 ACI 318-08 Eq. (D-9) 3 ho / WeAN = 0,7 + 0,3 ( 1:9 1,0 ACI 318-08 Eq. (D-11) Waal = MAXt, 1— ):5 1,0 cae ACI 318-08 Eq. (D-13) Nb = kc b A h!s ACI 318-08 Eq. (D-7) Variables her Gn•] ema on.) e,M tend q,,N, M•) w 2,000 0,000 01 4,000 1,000 c., on.] ke f. [01 3,875 24 1 3000 Calculations AN. [n.1 Anmo Gn•1O eaN .N Nb Db] , 36, 1,000 ,0 0 1,000 1,000 3718 ResuMs Nb Pb) Nw Vb) Nua tlbl 3718 0,650 2417 159;r- 554 input dela enol muff must be &adced for MmwneM vM cit axis" moons OW fbr pled * PROM Ar dw (c) 2003-2009 WO AG, FLAW Sdmw Hilts is a registered Tmdwnerk cf Mff AG, Gdwn 18/20 www.hiiti.us Prof1s Anchor 2A.1 Company: (ENGINEER, PLLC. Page: 4 Specifier. JUAN C. MORENO Project Address: 9920 NW 44TH TER. 41306 DORAL FL 33178 Sub -Project I Pos. No.: Phone I Fax. 954 274 2429 786 545 7636 Date: 22/07/2013 E -Mail: juan@iengineerpllacom 4 Shear load Load Vu. Pb] Capacity V, 001 Utilization ov = V„/4V, status SW Strerw 259 zoub 9 O Steel failure (with lever arm)' N/A WA WA N/A Pryout Strength" 259 2603 10 OK Concrete edge failure in direction x " 259 4288 7 OK *anchor having the highest loading "anchor group (relevant anchors) 4.1 Steel strength V„ = ESR value refer to ICC -ES ESR -2302 m Val a V,0 ACI 318-08 Eq. (D-2) Variables n A,, v Pn.1 f,m (psi] 1 0,05 108000 calculations Vaa (Ib) 4470 Results V,a Pbl b V,a Pbl Vas Pb] 447T- 0,550 2905 259 4.2 Pryout Strength V,= k, [(�ANC > WAN W,N WmN Nei ACI 318-08 Eq. (D-30) t V -P a V. ACI 318-08 Eq. (D-2) AN, see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANW = 9 h2,r ACI 318-08 Eq. (D-6) 1 WeaN= 1 2+ eN s 1,0 ACI 318-08 Eq. (D-9) h,r W.d,N = 0,7 + 0,3(, s 1,0 ACI 318-08 Eq. (D-11) W,,. = MAX( , 1 Ca..) 51,0 ACI 318-08 Eq. (D-13) Nb = k,)Lf t>el$ ACI 318.08 Eq. (D•7) Variables h.r On.] e.1N Dn.] eo2,N [In.] ce.m. Dn.) 1 ZOU0 0,wo 0,0U0 4,000 o,Nc.. M•1 k. X f. [pw7 0 1, 3,875 24 1 Calculations AN. Pn•21 AKw Uhlec1 .�N N Nb Pbl 36,00 1,000 1,000 1, 1,000 3718 Results V Pbl 0.w e V Pbl V. Pb) 371 0,7 2203 259 Input dam mid MUM mtret be dtecked for agreement with ute mds*q eta mid for pm "l PROFIS Ar dw (c) 2W3.2W9 HN AG, FL -9494 Sdmm Hni N a reglamred Tek or HA9 AG, Scham S 'Otl lBpi � 1 Phi a sl BAH ve48-ld'Ov BAH �Z-EOOZ (a) 3t�021d 14mWqdMPUBatroM=BMBM6414WW+ ft X); PMPMP eq WU MFM PmOPPPWin iepe;lio u619ep eta 040ow BUIU049e:1 IPJBPUBP ;uenelaj e43 jo 9 6£IOV 431M eouaw x , e ul paiinbaJ eye aouelslm JBs4s 843 Pug leuBMw eseq 843 OM SPBol Jo Jalsu84 843 BurW40 'suolpMsul uoaB nen PuB Bulueap M ajmwgi pnpoid 9awr4Wuew eW o;,apd . 'pmuep mm moi( o; Jwu '436um ;noNd PUB WAUMS 3nolind sol Pug PesnIOU 81;usw=(4uleu Aimusuieiddns u94M sapdds 8 uoalPuoo '436UQM 3no/Jd PuB 43Bu64S vmUnd;deoxa sy;BuMS uBiwa Iae;s-uou X4 Paseaioul sl SOP% m 841 'Paan sI Waw8Ox4ulGa Aimuawalddns ue4M selldde V uoppuoo IBUIpBoi eta o; pepWgns ue4m pauuolap eq o; Sou japes ul 'Ms dauepWs eq o; pewnsse sI a;eid jo4mm 841 •pajaplsuoo Sou aye emId Xarpue etg;o suoaawo;ep opsele o; anp sio4oue 843 uo suoangWsip-ei pal 'jo4wV SIAMId ul pe3elnOMO eq ueo WwPI4; paiinbei eta eMd impue egjo emliBi plom o1 . saulweM 9 N0 69£/9 ooL'0 £09'0 SMMS 1%] A uo4man E60Z/M= VVZ aoyauli ftOJd OZ/6 6 spool jostle pus uolsue; peu]gwoo 9 992001'0 9Z9_ [qIl e1A [gl17A [qd `*A synsaa 9z9z 000'6 opo'6 0�'6 00';L 00'09 [q0 °A A'4 APB A'� [Z'uIj °'^V Vul] *AV suoiMmIeo 000'; 000£ 9L£'0 6 000'Z XMBMm [iBd] °f ['W 8P I'ul] I 0001 00016 000'0 0001, 000'0 NO 84 A*Q ['u!] ft I'ud p0 ['u'.] 180 salgRIJBA (Oz -a) 'b3 90-96£ IOVs,a (Bpf► 1/ _ °A `'P ra (6z -a) 'b3 90-96£ IOV 0' 6 z� N = ANA (9Z-a)'b3MILE IOV 0'69\` 6�£`0+L'0=AI-AI t + 6) (9Z -a) 'b3 80-86£ IOV 0'6 s � "az = A.,Bm (£Z -a) 'b3 80-96£ IOV ID 91, - my (q) 6'Z'9'aM 'Bid ' 6'Z'9'a V `80 -86S 13V aas ON (Z -0)'b3 80-86£ IOV 81 A z `*A 0 (6;-a) 'b3 e0-86£ IOV IA A9 AI AM A'OA A'PeAI (DA) = aoA -x uop wip ul einpe; 96pe e; omo £'0 uwo'oil UmjBuer@uen[ :HBW-3 :saga 9E9L 909 99L 16ZOZ OLZ 096 :xBd 18Uo4d ,'oN 'sod I pe(oJd-MS OL ME ld I"OCI WW ?131 H100 MN OZ66 :SmppV P8fwd m iOw '6 NVnr :J vpedS :W3Bd 'olid 'LI33NIJN31 :Auedwoo �1UT1 www.hlla.us Profis Anchor 2A I Company: IENGINEER, PLLC. Page. 6 Speaer: JUAN C. MORENO Project Address. 9920 NW 44TH TER. #306 DORAL FL 33178 Sub -Project I Pos. No.: Phone 1 Fax 954 274 24291786 545 7636 Date: 22107/2013 E -Mail: juan(rj)lengineerpllc.com 7 Installation data Ancor plate, steel: - Angor type and diameter Kwik Bolt 3 - CS, 318 (2) Profile: no profile; 0,000 x 0,000 x 0,000 in. Installation torque. 240,000 In.lb Hole diameter In the fixture: df = 0,438 In. Hole diameter in the base material: 0,375 in. Plate thkkness (input): 0,250 In. Hole depth In the base material: 2,625 In. Recommended plate thickness: not calculated Minimum thickness of the base material: 5,000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use Is required. 1 1,0W 1 1,wo 1 Coordinates Anchor in. Anchor x y c x c.: c c 0, 4, - 4, - Input deft wM MMM must be &edwd for MMMO d w hh the wdsdnp wnftm and ror plausibdt 1 PROFIS A (c) 2003-2009 HUU AG, FL -9494 8dwn HUU k a registered TaK m ark cf HUU AG, Sdan 3 S o P P 1 1,0W 1 1,wo 1 Coordinates Anchor in. Anchor x y c x c.: c c 0, 4, - 4, - Input deft wM MMM must be &edwd for MMMO d w hh the wdsdnp wnftm and ror plausibdt 1 PROFIS A (c) 2003-2009 HUU AG, FL -9494 8dwn HUU k a registered TaK m ark cf HUU AG, Sdan At TYPICAL WELDING CONNECTION DETAIL "A" SCALE: N.T.S. 11611 "go ISOMETRIC sauri'm. . .. ALL MEMBERS MUST BE STEEL ASTM A992 GRADE 50 TUBE 1.315 O.D. X 14GA (GALVANIZED GATORSHIELD) &ESS NOTICED OTHERWISE) ISOMETRIC THE CANVAS AND OR FABRIC MUST BE DESIGNED TO BE READILY AND COMPLETELY REMOVED DURING PERIODS OF HIGH WIND VELOCITY. REMOVABLE CANVAS OR FABRIC MUST BE COMPLETELY REMOVED WHEN WIND SPEED APPROACH AND/OR EXCEED TO 75 MPH (34M/S) AND/OR AS DESIGNATED BY U.S. WEATHER BUREAU AS BEING A HURRICANE WARNING OR ALERT. A HIGH WIND VELOCITY WARNING MUST BE POSTED WITH LEGIBLE AND READILY VISIBLE SIGN OR DECAL INSTRUCTIONS TO THE OWNER OR TENANT TO REMOVE COMPLETELY THE CANVAS OR FABRIC DURING SUCH PERIODS OR TIME. THE CANVAS OR FABRIC USED FOR AWNINGS OR FABRIC -COVERED FRAMES SHALL BE FLAME RESISTANT IN ACCORDANCE WITH NFPA 701 "B" T. NMI 4)E$M LWrEDTO8M&AVWM Awl.-"mour OR 6nCK-0N8ML%1=THM DRAVMW Apo CAICUTATKM c0. THIS DOCUMeff ISTMPROPERf1 OF tFNOWEER AHDSHALL Fm1--. mm.EOR PART1MTf W171'VIRR'IFAI CONBEM OF TI¢ CERrWYM ENVIEM ra is V, u- .mc. �7 20-2013 J.M. J.M. SD --11 S iM t OF 2 J STRUCTURAL NOTES GENERAL NOTES: ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH THE AFFECTED PART OF THE WORK THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. DESIGN WIND LOADS: THE STRUCTURAL FRAMING WAS DESIGNED USING F.B.C. 2010 AND THE FOLLOWING SUPERIMPOSED LOADS. DESIGN WIND LOADS WERE DETERMINED IN ACCORDANCE WITH F.B.0 2010 AND ASCE 7-10. WIND VELOCITY :105 MPH EXPOSURE CATEGORY : C GCPI : +/-0.18 KD : 0.85 IMPORTANCE FACTOR :1.00 STRUCTURAL STEEL: THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION, AISC ASD, 13TH EDITION, 2005. ALL ANGLES AND PLATES SHALL BE ASTM A36, FY=38KS1 OR APPROVAL EQUAL U.N.O. ALL TUBES TO BE OUTSIDE DIAMETER, GALVANIZED GATORSHIELD, STEEL FY=50KSI.OR APPROVAL EQUAL, U.N.O. ALL HOLLOW STRUCTURAL TUBE "HSS" TO BE STEEL ASTM A5W GRADE B, FY=46KSI, OR APPROVAL EQUAL, U.N.O. ALL ANCHOR BOLTS SHALL BE KWIK BOLT III BY HILTI U.N.O., WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN-OF--THE-NUT METHOD. WELDING SHALL BE DONE BY AWS CERTIFIED WELDERS USING THE MOST RECENT AWS APPROVED TECHNIQUES. SHIELDED METAL ARC WELDING (SMAW) SHALL USE E70XX LOW -HYDROGEN ELECTRODES. ALL STEEL SHALL RECEIVE SHOP AND FIELD TOUCH-UP COATS OF PAINT IN ACCORDANCE WITH SSPC SPECIFICATIONS. EXISTING STUCCO LINE OF FINISH WALL 3" MIN. SIDE VIEW 3/16 STEEL ANGLE ASTM A36 L2X2X1/4X2"LG W/ (1) KWIK BOLT -3 BY HILTI 3/8"0 X 3" MIN. EMBED. INTO CONCRETE (rc=3,000 p-s.i.) DETAIL "B" SCALE: N.T.S. FINISH WALL FRONT VIEW NOTE •DESIGNLOOTEDTOSTEELAM am d1NY CORRECTIONS, GSC . WF41 = OR=CK- VftL%f mTHMDRA%%lM AND CALOUTATIONS. COPYRKBif fFigtrev. TIES DOCUUM IS nffi P"OPOM OF IENOilff6t AND 8MALL NOTSER6+ROWCED W "MOLE OR PA" %"V=%VW" 7COMMIT OP THE CERT NIMI ENGPIEER cl) V z O 0 z z ` � 2 13 le 2c VALID ONLY SE VALID 1)PERAaoNLY FL P.E #69818 07 22 2073. AS SHOWN J.M. J.M. U Awmu flu. SD -2- SHEET 2 OF 2