Loading...
DGT-14-681Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-210310 Scheduled Inspection Date: September 24, 2014 Inspector: Rodriguez, Jorge Owner: BARROSO, CARLOS Job Address: 253 NE 104 Street Miami Shores, FL Project: <NONE> Contractor: HOME OWNER Building Department Comments PERGOLA & PORCH Permit Number: DGT-4-14-681 Permit Type: Decks/Gazebos/Trellises Inspection Type: Final Work Classification: Pergola Phone Number (786)546-1614 Parcel Number 1121360130590 Infractio Passed Comments INSPECTOR COMMENTS False September 23, 2014 For Inspections please call: (305)762-4949 Page 3 of 25 Inspector Comments Passed Failed Correction Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. September 23, 2014 For Inspections please call: (305)762-4949 Page 3 of 25 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fag: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILD G PERMIT APPLICATION Permit Type: JOB ADDRESS: BUILDING APR �0 L FBC 20 Permit 0�6—F �� �" U Master Permit No. ROOFING City: Miami Shores County: Miami Dade Zip: Folio/Parcelt Is the Building Historically Designated: Yes NO Flood Zone: P OWNER: Name (Fee Simple Titleholder): �C� Ste` Phone#:� Address: 1 (® `t City: Tenant \ < U State: e Zip: /I Email: .essee Name: Phone#: 7 R G, CONTRACTOR: Company Name: Phone#: Address: City: State: Qualifier Name: Phone#: State Certification or Registration #: Certificate of Competency #: Contact Phone#: Email Address: DESIGNER: Architect/Engineer: Phone#: Value of Work for this Permit: $®USquare/Linear Footage of Work: Type of Work: ®Addition ❑Alteration ❑New ❑Repair/Replace ❑Demolition Description of Work:�— Color thru tile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Notary $ Radon Fee $ Training/Education Fee $ Double Fee $ Structural Review $ DBPR $ Bond Technology Fee $ TOTAL FEE NOW DUE $ ?_)10a Bonding Company's Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address Zip City State Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant. As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature _ Signature Owner or Agent Contractor The foregoing instrument was acknowledged before me this day of -/�`'' 20 �� , by S (� �� , who is personally known to me or who has produced't As identification and who did take an oath. NOTARY PUBLIC: Sign: Print: My Commission Expires: APPROVED BY The foregoing instrument was acknowledged before me this day of .20 _, by , who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: V911d 4 Structural Review Clerk (Revised 3/12/2012)(Revised 07/10/07)(Revised 06110/2009)(Revised 3/15/09) Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNER BUILDER DISCLOSURE STATEMENT NAME: _ E7S� Q.) DATE: ADDRESS: iJ F- r 0 t -r <" � ' ' Do hereby petition the Village of Miami Shores to act as my own contractor pursuant to the laws of the State of Florida, RS 489.103(7). And I have read and understood the following disclosure statement, which entitles me to work as my own contractor; I further understand that I as the owner must appear in person to complete all applications. State Law requires construction to be done by a licensed contractor. You have applied for a permit under an exception to the law. The exemption allows you, as the owner of your property, to act as your own contractor even though you do not have a license. You must supervise the construction yourself. You may build or improve a one -family or two-family residence. You may also build or improve a commercial building at a cost of $25,000.00 or less (The new form states 75,000). The building must be for your own use and occupancy. ft may not be built for sale or lease. if you sell or lease a building you have built yourself within one year after the construction is complete, the law will presume that you built for sale or lease, which Is a violation of this exemption. You may not hire an unlicensed person as a contractor. It is your responsibility to make sure the people employed by you have licenses required by state law and by county or municipal licensing ordinances. Any person working on your building who is not licensed must work under your supervision and must be employed by you, which means that you must deduct F.I.C.A and with- holdings tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, buildings codes and zoning regulations. Please read and initial each paragraph. 1. I understand that state law requires construction to be done by a licensed contractor and have applied for an owner -builder permit under an exemption from the law. The exemption specifies that 1, as the owner of the property listed, may act as my own contractor with certain restrictions even though I do not have a license. Initial 2. 1 understand that building permits are not required to be signed by a property owner unless he or she is responsible for the construction and is not hiring a licensed contractor to assume responsibility. Initial-4 nitial C- 3. 1 understand that, as an owner builder, I am the responsible party of record on a permit. I understand that I may protect myself from potential financial risk by hiring a licensed contractor and having the permit filed in his or her name instead of my own name. I also understand that the contractor is required by law to be licensed in Florida and to list his or license tubers on permits and contracts. Initial 4. 1 understand that I may build or improve a one family or two-family residence or a farm outbuilding. I may also build or improve a commercial building if the costs do not exceed $75,000. The building or residence must be for my use or occupancy. It may not be built or substantially improved for sale or lease. If a building or residence that I have built or substantially improved myself is sold or leased within 1 year after the construction is complete, the law will presume that I built r tantially improved it for sale or lease, which violates the exemption. Initial 5. 1 understand that, as the owner -builder, I must provide direct, onsite supervision of the construction. Initial 6. 1 understand that I may not hire an unlicensed person to act as my contractor or to supervise persons working on my building or residence. It is my responsibility to ensure that the persons whom I employ have the license required by law and unty or municipal ordinance. Initial LC 7. 1 understand that it is frequent practices of unlicensed persons to have the property owner obtain an owner -builder permitthat - erroneously implies that the property owner is providing his or her own labor and materials. I, as an owner -builder, may be held liable and subjected to serious financial risk for any injuries sustained by an unlicensed person or his or employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an owner -builder and am aware of the limits of my insurance coverage for injuries to workers on my property. Initial 8. 1 understand that I may not delegate the responsibility for supervising work to be a licensed contractor who is not licenses to perform the work being done. Any person working on my building who is not licensed must work under my direct supervision and must be employed by me, which means that I must comply with laws requiring the withholding of federal income tax and social security contributions under the Federal Insurance Contributions Act (FICA) and must provide workers compensation for the employee. I understand that my failure to follow these may subject to serious financial risk. rK Initial 9. 1 agree that, as the party legally and financially responsible for this proposed Construction activity, I will abide by all applicable laws and requirement that govem owner -builders as well as employers. I also understand that the Construction must comply with all applicable laws, ordinances, building odes, and zoning regulations. Initial 10. 1 understand that I may obtain more information regarding my obligations as an employer from the Intemal Revenue Service, the United States Small Business Administration, and the Florida Department of Revenues. I also understand that I may contact the Florida Construction Industry Licensing Board at 850.487.1395 or h ://www.m ffoddalicense.com/db r/ ro/cilbfiindex.ht I Initial 11. 1 am aware of, and consent to; an owner -builder building permit applied for in my name and understands that I am the party legally and financially responsible for the propoRlconstruction activity at the following address: Initial C 12. 1 agree to notify Miami Shores Village immediately of any additions, deletions, or changes to any of the information thptl have provided on this disclosure. Initial Licensed contractors are regulated by laws designed to protect the public. If you contract with a person who does not have a license, the Constr4uction Industry Licensing Board and Department of Business and Professional Regulation may be unable to assist you with any financial loss that you sustain as a result of contractor may be in civil court. It is also important for you to understand that, if an unlicensed contractor or employee of an individual or firm is injured while working on your property, you may be held liable for damages. If you obtain an owner -builder permit and wish to hire a licensed contractor, you will be responsible for verifying whether the contractor is properly licensed and the status of the contractor's workers compensation coverage. Before a building permit can be issued, this disclosure statement must be completed and signed by the property owner and retumed to the local permitting agency responsible for issuing the permit. A copy of the property owner's driver license, the notarized signature of the property owner, or other type of verification acceptable to the local permitting agency is required when the permit is issued. Was acknowledged before me this day of A,IP2`'l— , 20 "1 By who was personally known to me or v�4oi gas,,,, vera `' Produced there License orasCM- cc F, NER NOTIA�YSTgTE ALIOSKAR GANEM, P.E. Lic. # 74745 m 1380 NE MIAMI GARDENS DR UNIT 205 North Miami Beach — Florida 33179 Phone (786) 916-6546 Fax (305) 848-9318 alioskar@hotmail.com PAGE 115 COVER SHEET DATE: May 06, 2014 PROJECT: NEW WOOD TRELLIST ADDRESS: 253 NE 104Th ave Miami Shores, FL. 33179 CLIENT: CARLOS BARROSO DESIGN BY: AG This computation book contains manual and computerized structural calculations, certain printed manufacturer's data and Computation pages are numbered 1 thru 15. Computations were performed to the best of our knowledge according to sound and generally accepted engineering principals and Code requirements, using nationally recognized computer software and in-house developed software. Prior to commissioning into service, the in-house developed software was thoroughly check Iii d` parallel manual computations. The sign and seal provided herein are meant to 104 • ••••. sheets pages 1 through 15. ,�� �►•••�� NS+ •��lj�•� • ; �i • 7 7 L • r x°06 I�=� Z9 y41i L'� m: : �b �ONALE�.���,, X111111111 PAGE INDEX DESCRIPTION PAGE Wind Design (MWFRS) 1 Strap Calculation 5 Wood Joist Design 6 Wood Girder Design 7 Bolted Connection Design 8 Fill Cell Design 13 Wall Foundation Design 15 irW MECAWind Version 2.1.0.6 per ASCE 7-10 Developed by MEGA Enterprises, Inc. Copyright 2014 www.mecaenterpr.ises.com Date 5/6/2014 Project No. Company Name Designed By Address Description City Customer Name State Proj Location File Location: \\PC-A00\Users\2lann 000\Documents\PR0JECTS\CARL0S BARROSO\WIND.wnd Directional Procedure All Heights Building (Ch 27 Part 1) All pressures shown are based upon STRENGTH Design, with a Load Factor of 1 Basic Wind Speed(V) = 175.00 mph Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor = 1.00 Kd Directional Factor = 0.85 Damping Ratio (beta) = 0.01 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Em = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 0 : 12 Slope of Roof(Theta) _ .00 Deg Ht: Mean Roof Ht = 15.00 ft Type of Roof = Monoslope RHt: Ridge Ht = 15.00 ft Eht: Eave Height = 15.00 ft OH: Roof Overhang at Eave= .00 ft Roof Area = 1350.00 ftA 2 Bldg Length Along Ridge = 45.00 ft Bldg Width Across Ridge= 30.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq.>1 Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6*Ht = 15.00 ft lzm: Cc*(33/Zm)A0.167 = 0.23 Lzm: 1*(Zm/33)AEpsilon = 427.06 ft Q: (1/(1+0.63*((B+Ht)/Lzm)'0.63))A0.5 = 0.93 Gust2: 0.925*((1+1.7*lzm*3.4*Q)/(1+1.7*3.4*lzm)) = 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11-1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/-0.18 Figure 27.4-1 External Pressure Coefficients Cp - Loads on Main Wind -Force Resisting Systems LI Kj 2/15 B Kh: 2.01*(Ht/Zg)�(2/Alpha) = 0.85 Kht: Topographic Factor (Figure 6-4) = 1.00 Qh: .00256*(V)A2*I*Kh*Kht*Kd = 56.57 psf Cpww: Windward Wall Cp(Ref Fig 6-6) = 0.80 Roof Area = 1350.00 ftA2 Reduction Factor based on Roof Area = 0.80 MWFRS-Wall Pressures for Wind Normal to 45 ft wall (Normal to Ridge) Wall CP Pressure Pressure +Gcpi (psf) -Gcpi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.50 -34.22 -13.86 Side Walls -0.70 -43.84 -23.48 Wall Slev Kz Kzt qz Press Press Total ft psf +Gcpi -Gcpi +/-Gcpi ---------------- ------ ----- -------------------------- --------- Windward 15.00 0.85 1.00 56.57 28.28 48.65 62.51 Note: 1) Total = Leeward GCPi + Windward GCPi Roof - Dist from Windward Edge Cp Pressure Pressure +GCpi(psf)-GCpi(psf) --------------------------------- ------ ---------- ---------- 0.0 ft to 7.5 ft -0.90 -53.46 -33.09 7.5 ft to 15.0 ft -0.90 -53.46 -33.09 15.0 ft to 30.0 ft -0.50 -34.22 -13.86 MWFRS-Wall Pressures for Wind Normal to 30 ft wall (Along Ridge) Wall CP Pressure Pressure +Gcpi (psf) -GCpi (psf) --------------- ------ ----------- ----------- Leeward Wall -0.40 -29.42 -9.05 Side Walls -0.70 -43.84 -23.48 3/15 Wall Elev Rz Kzt qz Press Press Total ft psf +GCpi -GCpi +/-GCpi ---------------- ------ ----- ----- ------- -------------- --------- Windward 15.00 0.85 1.00 56.57 28.28 48.65 57.70 Note: 1) Total = Leeward GCPi + Windward GCPi Roof - Dist from Windward Edge CP Pressure Pressure --------------------------------- +GCpi(psf) -GCpi(psf) 0.0 ft to 7.5 ft ------ -0.90 ---------- -53.46 ---------- -33.09 7.5 ft to 15.0 ft -0.90 -53.46 -33.09 15.0 ft to 30.0 ft -0.50 -34.22 -13.86 30.0 ft to 45.0 ft -0.30 -24.61 -4.24 MECAWind Version 2.1.0.6 ASCE 7-10 Developed by MECA Enterprises, Inc. Copyright 2014 www.mecaenterprises.com Date 5/6/2014 Project No. Company Name Designed By Address Description City Customer Name State Proj Location File Location: \\PC-AGO\Users\plann 000\Documents\PROJECTS\CARLOS BARROSO\WIND.wnd saff5 M El 4/15 Wind Pressure on Components and Cladding (Ch 30 Part 1) All pressures shown are based upon STRENGTH Design, with a Load Factor of 1 Width of Pressure Coefficient Zone °a° = 3 ft Description Width Span Area Zone Max Min Max P Min P ft ft ft"2 GCp GCp pof psf -------------------------------------------------------------------------- JOIST 0.50 5.67 10.7 1 0.30 -1.00 26.98 -66.58 JOIST 0.50 5.67 10.7 2 0.30 -1.78 26.98 -110.82 JOIST 0.50 5.67 10.7 3 0.30 -2.75 26.98 -165.69 Khcc:Comp. & Clad. Table 6-3 Case 1 = 0.85 Qhcc:.00256*VA2*Khcc*Kht*Kd = 56.57 psf PROJECT: STRAP DESIGN SUBJECT: ADDRESS: SHEET No. DATE: EO DESIGN BY: OF STRAP DESIGN BASED ON ' SCE 7-10 ENTRY DATA GRAVITY = D + L P1 P2 L4 t L5 L LE Wind Pressure 111 psf (ULTIMATE) Wind Lateral Ult 0 psf (MWFRS) DEAD LOAD 25 psf LIVE LOAD 30 psf 1 2 L1 0.00 ft L3 t . L TOTAL L2 5.67 ft L3 Bldg. Width 1.67 it 45.00 it NET UPLIFT = 0.61D + 0.6WIND P, P2 Bldg. Height 65.00 ft Parapet Height 0.00 it LAT G)LAT 1 JOIST SEPARATION 1.5 in 1 2 L, L2 L3 l CONCENTRATED LOAD P1 P2 L TOTAL DEAD LOAD LIVE LOAD WIND LOAD L4 TRUSS SEPA Ar/ON �L3� /y tqr 0.0 Ib 0.0 Ib 0.0 Ib 0.00 ft 0.0 Ib 0.0 Ib 0.0 Ib L5 0.00 It j RS L TOTAL 7.34 ft STRAP 1: USE (1) AC7 BY UNITED STEEL PRODUCTS W/(4) 10d COMMON L5 5.67 it NAILS INTO HEADER & (4) 10d NAILS INTO JOIST REACTION 1 FL 820 Span 2.84 ft GRAVITY 450.0 Ib [OK] Gravity (Concentr.) 0.0 lb UPLIFT 725.0 lb [OK] Gravity (Distributed) 19.5 Ib LATERAL 1 NA Total Gravity (R1) 19.6 lb LATERAL 2 NA 0.6 D 10 psf STRAP 2: USE (1) HGA10 BY UNITED STEEL PRODUCTS W/(4) WS3 0.6 W 66.6 psf INTO PLATE & 4 WAS 15 INTO RAFTER Net Uplift (Concentr.) 0.0 Ib FL 817 Net Uplift -20.1 Ib GRAVITY NA Total Net Uplift (111) -20.1 Ib UPLIFT 1285.0 Ib [OK] REACTION 2 LATERAL11 NA Span 4.51 ft LATERAL 2 NA Gravity (Concentr.) 0.0 lb SUMMARY Gravity 31.0 Ib LOAD R1 R2 LAT 1 LAT 2 Total Gravity (R2) 31.0 ib GRAVITY 19.6 lb 31.0 Ib 0.6 D 10 psf NET UPLIFT 20.1 Ib 31.9 Ib 0.6 W 66.6 psf LATERAL 0.0 Ib 0.0 Ib Net Uplift (Concentr.) 0.0 Ib STRAP INTERACTION EVALUATION Net Uplift -31.9 Ib Total Net Uplift (R2) -31.9 lb LATERAL LOAD 1 ANALYSIS Actual twift Acholist1r Actualmr2 AnowaKrupult AmwoweLatz Lat. Wind Reaction 0.0 Ib@ft Strap 1 0.03 0.00 0.00 0.03 [OK] Load (LAT 1) 0.0 lb (ASD) Strap 2 0.02 0.00 0.00 0.02 [OK] LATERAL LOAD 2 ANALYSIS Lat. Wind Reaction 0.0 Ib@ft Load (LAT 2) 0.0 lb (ASD) 6/15 WOOD JOIST DESIGN LOADS BASED ON NDS 2005 & ASCE 7-10 DL = 25.00 psf DL = 10.00 psf + LL = 30.00 psf 0.6 UPLIFT = -66.60 psf UL = 55.00 psf UL = -56.60 psf U L (WL 1.33 REDUCTION) = -56.60 psf Ltributa = 0.50 ft Wmax = 28.30 #/ft WOOD BENDING AND DEFLECTION DEFLECTION L = 5.67 ft Wmax = 28.30 */,, b = 1.50 in d = 7.50 in Fb = 1,200.00 psi CD=1.0 E = 1.60E+06 psi I = 52.73 in4 (DL+LL) A= 0.01 in DL+LLL/240 Aperm= 0.28 in, FBC 1610.1 Lmax = 18.96 ft. Allowable for deflection to DL + LL. ( LL ) A = 0.00 in LL ->L/360 Aperm= 0.19 in, FBC 1610.1 Lmax = 20.27 ft. Allowable for deflection to LL. 0 �OK Aperm BENDING Mmax = 113.73 # - ft VGRavITY = 155.93 # - ft S = 1.14 in VNET UPLIFT = 80.23 # - ft SX = 14.06 in S 5, OK SX Lmax = 19.94 ft. Allowable for bending USE WOOD I JOIST (1) 2 X 8 @ SUPPORT 7/15 WOOD GIRDER DESIGN LOADS BASED ON NDS 2005 & ASCE 7-10 DL = 25.00 psf DL = 10.00 psf + LL = 30.00 psf + 0.6 UPLIFT = -66.60 psf UL = 55.00 psf U L = -56.60 psf U L (WL 1.33 REDUCTION) = -56.60 psf Lbibutary= 1.50 ft Wmax = 84.90 #/ft WOOD BENDING AND DEFLECTION DEFLECTION L = 14.33 ft Wmax = 84.90 #/ft b = 3.00 in d = 7.50 in Fb = 1,200.00 psi CD=1.0 E = 1.60E+06 psi I = 105.47 in 4 (DL + LL) A= 0.46 in DL+LL—>L/240 Aperm= 0.72 in, FBC 1610.1 Lmax = 16.57 ft. Allowable for deflection to DL + LL. ( LL ) A = 0.25 in LL—>L/360 Aperm= 0.48 in, FBC 1610.1 Lmax = 17.71 ft. Allowable for deflection to LL. A5, OK Aperm BENDING Mmax = 2,179.27 # - ft VGRavITY = 394.08 # - ft S = 21.79 in VNET UPLIFT = 608.31 # - ft SX = 28.13 in S 5, OK SX Lmax = 16.28 ft. Allowable for bending USE WOOD I JOIST (2) 2 X 8 @ SUPPORT www.hiiti.us Company: Specifier. Address: Phone i Fax: E -Mail: Specifiees comments: 1 Input data Anchor type and diameter. Effective embedment depth: Material: Evaluation Service Report Issued I Valid: Proof Stand-off installation: Anchor plate: Profile: Base material: Reinforcement Seismic loads (cat. C, D, E, or F) Geometry On.] S Loading Ob, In.lb] 0,46 Profis Anchor 2.4.6 Page: 1 Project Sub -Project I Pos. No.: Date: 5/6/2014 Kwik Bolt TZ - CS 3/8 (2)i hef = 2.000 in., hnem = 2.313 in. Carbon Steel ESR -1917 5/1/201315/1/2015 design method ACI 318 /AC193 eb = 0.000 in. (no stand-off); t = 0.500 in. 1, x ly x t = 8.000 in. x 8.000 in. x 0.500 in.; (Recommended plate thickness: not calculated) no profile cracked concrete, 3000, f� = 3000 psi; h = 8.000 in. tension: condition B, shear. condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar no Input date and results must be checked for agreement with the existing conditions and for plausiblRt l PROFIS Anchor (c) 2003-2009 Hilt[ AG, FL -9494 Schaan Hird is a registered Trademark of Hilt AG, Schaan www.hitti.us Company: Specifier. Address: Phone I Fax: E -Mail: 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions Ob] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 0 300 300 0 2 0 300 300 0 3 0 300 300 0 4 0 300 300 0 max. concrete compressive strain: - [°k,] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 0 [lb] resulting compression force in (x/y)=(0.000/0.000): 0 [lb] 3 Tension load t11116 Profis Anchor 2.4.6 Page: 2 Project: Sub -Project I Pos. No.: Date: 5/6/2014 Y 03 04 x 01 02 Load A [Ib] Capacity 0. [Ib] UtilizationA= Nual^ Status Steel Strength' N Pullout Strength' N/A N/A N/A N/A Concrete Breakout Strength" N/A N/A N/A N/A "anchor having the highest loading "anchor group (anchors in tension) Input data and results must be checked for agreement with the eAsting conditions and for plausibilityl PROFIS Anchor (c) 2003.2009 HIM AG, FL -8494 Schaan Hilt is a registered Trademark of Hilt AG, Schaan www.hiitl.us 4611116 Profis Anchor 2.4.6 Company: Page: 3 Specifier: Project: Address: Sub -Project I Pos. No.: Phone I Fax: Date: 5/6/2014 E -Mail: N/A 4 Shear load ` anchor having the highest loading —anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC -ES ESR -1917 0 Va.i z Vas ACI 318-08 Eq. (D-2) Variables n Assy [in 2] ft. [psi] 1 0.05 125000 Calculations V. [lb] 3595 Results V. [lb] 4steel V. [lb] V. [lb] 3595 0.650 2337 300 4.2 Pryout Strength V_ = kop [(ANNA) Wec,N Wed,N Wc,N Wop,N Nyl ACI 318-08 Eq. (D-31) � Vcpg s V. ACI 318-08 Eq. (D-2) ANa see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANcO = 9 hof ACI 318-08 Eq. (D-6) 1 W.N = 1 l 51.0 ACI 318-08 Eq. (D-9) 3 ham/ Wed,N = 0.7 + 0.3 ( h J s 1.0 ACI 318-08 Eq. (D-11) WAN = MAX(ce,,,d„ 1.5h., 51.0 ACI 318-08 Eq. (D-13) \\ cac , Cec Nb = kc A, 1�f: har ACI 318-08 Eq. (D-7) Variables Load V. [Ib] Capacity 1bVn Ob] Utilization N = V11e OVn Status Steel Strength- 300 2337 13 OK Steel failure (with lever arm)' N/A N/A N/A N/A Pryout Strength" 1200 4148 29 OK Concrete edge failure in direction x+`* 1200 3979 31 OK ` anchor having the highest loading —anchor group (relevant anchors) 4.1 Steel Strength Vsa = ESR value refer to ICC -ES ESR -1917 0 Va.i z Vas ACI 318-08 Eq. (D-2) Variables n Assy [in 2] ft. [psi] 1 0.05 125000 Calculations V. [lb] 3595 Results V. [lb] 4steel V. [lb] V. [lb] 3595 0.650 2337 300 4.2 Pryout Strength V_ = kop [(ANNA) Wec,N Wed,N Wc,N Wop,N Nyl ACI 318-08 Eq. (D-31) � Vcpg s V. ACI 318-08 Eq. (D-2) ANa see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANcO = 9 hof ACI 318-08 Eq. (D-6) 1 W.N = 1 l 51.0 ACI 318-08 Eq. (D-9) 3 ham/ Wed,N = 0.7 + 0.3 ( h J s 1.0 ACI 318-08 Eq. (D-11) WAN = MAX(ce,,,d„ 1.5h., 51.0 ACI 318-08 Eq. (D-13) \\ cac , Cec Nb = kc A, 1�f: har ACI 318-08 Eq. (D-7) Variables kcp hef [in.] ec1 N [n.] ec2 N [in.] c6,dn [in.] 1 2.000 0.000 0.000 3.500 Wc,N c. [in.] kc A, fc [psi] 1.000 4.000 17 1 3000 Calculations AN. [int n] A wco [int] Wec1 N Wec2,N Wed.N WCP N Nb [Ib] 81.00 36.00 1.000 1.000 1.000 1.000 2634 Results Vcpg [lb] �concreta Vcpg [lb] Vas [lb] 5926 0.700 4148 1200 Input data and results must be checked for agreement with the existing conditions and for plausibilityl PROMS Anchor (c) 2003.2009 HIM AG, FL -9494 Schaan Hird is a registered Trademark of Hilt AG, Schaan www.hilti.us Company: Specifier: Address: Phone I Fax: E -Mail: 4.3 Concrete edge failure In direction x+ V� — (Avco W..V Wed,v Wc,v Wh,v Wpareaet.v Vb ACI 318-08 Eq. (D-22) V ft z Vua ACI 318-08 Eq. (D-2) Ave, see ACI 318-08, Part D.6.2.1, Fig. RD. 6.2.1(b) Avco = 4.5 cep ACI 318-08 Eq. (D-23) 1 W.,v = (T. 1 51.0 ACI 318-08 Eq. (D-26) 3cat Wad,v = 0.7 + 0.3(1 mat / 51.0 ACI 318-08 Eq. (D-28) 1'9 Wh,v = 2 1.0 h. ACI 318-08 Eq. (D-29) �� Vb = (7 (1--)02 -Z.)?< Vic �i e ACI 318-08 Eq. (D-24) d 14 1116 Profis Anchor 2.4.6 Page: 4 Project: Sub -Project I Pos. No.: Date: 5/6/2014 Variables cat [in.] ca2 [in.] ecv [in.] Wery ha [in.] 6.500 423.500 0.000 1.000 8.000 le [in.] X da [in.] fc [psi] WpweOel,y 2.000 1.000 0.375 3000 1.000 Calculations Avc [in•2] Avco [in.2 Wecy Wedv Whv Vb [lb] 180.00 190.13 1.000 1.000 1.104 5438 Results Vcb, [Ib] Oconcrets O V�ln [Ib] Vaa [lb] 5684 0.700 3979 1200 5 Warnings • To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re -distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! • Condition A applies when supplementary reinforcement is used. The 0 factor is increased for non -steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! Fastening meets the design criteriad Input data and results must be checked for agreement with the spsting conditions and for plausibility! PROMS Anchor (c) 20032009 Hilt! AG, FL -9494 Schaan Hilti is a registered Trademark of Hilt AG, Schaw www.hiiti.us Profis Anchor 2.4.6 Company: Page: 5 Specifier: Project Address: Sub -Project I Pos. No.: Phone I Fax: Date: 5/6/2014 E -Mail: 3.500 6 Installation data Anchor plate, steel: - Anchor type and diameter. Kwik Bolt TZ - CS, 3/8 (2) Profile: no profile; 0.000 x 0.000 x 0.000 in. Installation torque: 300.000 in.lb Hole diameter in the fixture: df = 0.438 in. Hole diameter in the base material: 0.375 in. Plate thickness (input): 0.500 in. Hole depth in the base material: 2.625 in. Recommended plate thickness: not calculated Minimum thickness of the base material: 5.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. Y A nnn a nnn Coordinates Anchor In. Anchor x Y c -x 0 c-, c+y 1 u� -1.500 3.500 f"l 423.500 426.500 2 1.500 O O 6.500 6.500 O 3 -1.500 V' 03 9.500 426.500 423.500 4 1.500 0 0 6.500 vi 426.500 423.500 1 0 0 0 v 0 0 u� N 2.500 3.000 2.500 Coordinates Anchor In. Anchor x Y c -x c+x c-, c+y 1 -1.500 -1.500 3.500 9.500 423.500 426.500 2 1.500 -1.500 6.500 6.500 423.500 426.500 3 -1.500 1.500 3.500 9.500 426.500 423.500 4 1.500 1.500 6.500 6.500 426.500 423.500 Input date and results must be checked for agreement with the existing conditions and for plausibilityl PROMS Anchor (c) 2003-2009 HIM AG, FL -9494 Schaan Hilt is a registered Trademark of Hilt AG, Schaan x Min: 1 at 3 ft Min: -.188 at 3 ft Max: .141 at 1.5 ft k/ft I k/ft I k P Max: 1.165 at 0 ft V Max: .188 at 0 ft APPLIED LOADS DETAILS Load Pressure Load, Q Axial Load,P Category 13/15 Company 0 0.5 LL 0 0.5 May 6, 2014 Designer WL 0.125 0 STAIR FILL CELL BENDING SUMMARY Job Number: fb :.057 FILL—CELL Checked By: CRITERIA ksi MATERIALS :4.953 GEOMETRY Code : MSJCO2 / IBCI93sonry fm : 1.5 ksi Total Height :3 ft Special Insp : Yes Masonry Em :1125 ksi Eq Sid Thickness: 4.604" Reinforced : Reinforced Steel fy : 60 ksi Blk Grouting : Partially Grouted Slender : No Steel E : 29000 ksi GrtBar Spacing : 48" Vertical Bar Size: #6 Blk Material : Conc 135 pcf U End Face Dist : 4.81 in Grt Weight : 140 pcf ENVELOPE DIAGRAMS Min: 1 at 3 ft Min: -.188 at 3 ft Max: .141 at 1.5 ft k/ft I k/ft I k P Max: 1.165 at 0 ft V Max: .188 at 0 ft APPLIED LOADS DETAILS Load Pressure Load, Q Axial Load,P Category Magnitude (ksf) Magnitude (k/ft) DL 0 0.5 LL 0 0.5 EL 0 0 WL 0.125 0 IT COMBINED CHECKS (fa + fb)/Fb :.154 fa/Fa :.053 fs/Fs :.206 AXIAL SUMMARY fa :.02 ksi Fa :.371 ksi BENDING SUMMARY fb :.057 ksi Fb :.5 ksi fs :4.953 ksi Fs :24 ksi SHEAR CHECKS fv/Fv :.091 u/U :.43 SHEAR SUMMARY fv :.004 ksi Fv :.039 ksi u :.086 ksi U :.2 ksi Moment,M Line Load,L Magnitude (k) Magnitude (k/ft) 0 0 0 0 0 0 0 0 Height, H1 (ft) 0 0 0 0 RISAMasonry Version 1.0 [Untitled.rma] Page 1 RISAMasonry Version 1.0 [Untitled.rma] Page 2 14/15 Company May 6, 2014 Designer STAIR FILL CELL Job Number: FILL—CELL Checked By: DESIGN DETAILS AXIAL DETAILS BENDING DETAILS SHEAR DETAILS Max Axial : 1.083 k/ft Max Moment :.141 k Max Shear :.188 k/ft Location :1.5 ft Location :1.5 ft Location :0 ft Load Comb : 5 Load Comb : 5 Load Comb : 5 Rad gyration r : 2.66 in k :.23 Sh Wdth/c/c Reinf 48 in h'/r : 13.534 d : 4.81 in Perimtr/c/c Reinf : 1.963 in Red Factor R :.991 j :.923 LOAD COMBINATIONS LC Label ASIF DL LL EL WL SL RLL OL 1 IBC 16-7 1 1 0 0 0 0 0 0 2 IBC 16-8 1 1 1 0 0 0 0 0 3 IBC 16-9 a 1 1 1 0 0 0 1 0 4 IBC 16-9 b 1 1 1 0 0 1 0 0 5 IBC 16-10 a 1 1 1 0 1 0 1 0 6 IBC 16-10 b 1 1 1 0 -1 0 1 0 7 IBC 16-10 c 1 1 1 0 1 1 0 0 8 IBC 16-10 d 1 1 1 0 -1 1 0 0 9 IBC 16-10 e 1 1 1 0.7 0 0 1 0 10 IBC 16-10 f 1 1 1 -0.7 0 0 1 0 11 IBC 16-10 g 1 1 1 0.7 0 1 0 0 12 IBC 16-10 h 1 1 1 -0.7 0 1 0 0 13 IBC 16-11 a 1 0.6 0 0 1 0 0 0 14 IBC 16-11 b 1 0.6 0 0 -1 0 0 0 15 IBC 16-12 a 1 0.6 0 0.7 0 0 0 0 16 IBC 16-12 b 1 0.6 0 -0.7 0 0 0 0 RISAMasonry Version 1.0 [Untitled.rma] Page 2 15/15 PROJECT: SUBJECT: ADDRESS: DATE: DESIGN BY: 1PRESSURE : DEAD LOAD : LIVE LOAD ALL. PRESSURE :SPAN (L) :OVERHANG (1-1) )NRY WALL (Y/N) HT (H) )NRY WEIGHT JD. HEIGHT (Wh) JD. WIDTH (Ww) JD. REBAR FOUNDATION DESIGN 54 psf (ULTIMATE) 35 psf 60 psf 2000 psf 5.67 ft 0.00 ft Y 3.00 ft 15.0 psf 12.00 in 12.00 in # 5 USE (2)REB. 'AN 2.84 ft ALL LOAD 45 Ib ft _LF WEIGTH 150 Ib ft + U 95.0 psf n+L 464.325 Wit Gravity Gov 3DI - 0.6W -11.4 psf n an+n ew 12.681 Ib/ft CAVITY LOAD 464.325 lb ft >UND. WIDTH 1.0 ft L SOIL PR. 2000 psf N WIDTH P :BAR AREA tEA REBAR INSTALLED N REBAR PER FOOTING SHEET No. USF- WALL FOUNDATION WF12 W/(2) # 5 REBAR AT OF BOTTOM �' --I DESIGN ADEQUATE GRAVITY = D + L 1 2 NET UPLIFT = 0.6D + 0.6WIND 1 2 L � 0.23 ft (2.79in) < 12.00 in OK 0.26 in"2 0.31 in"2 UNIT (2) # 5 REBAR IFT LOAD WIDTH WupIift N/A 150 pcf x Wh 5582 NX 7TH STREET, SqITE 202 MIAMI, FLORIDA 33126 JoUn TELEPHONE: (305) 220-3171 FAX: ($06) 654-78M 'ourvejono LAND SURVEYORS SKETCH OF SURVEY scale i"= 20' SURVEY NO. SHEET NO. r' �.3JE0"lM� �114'Gt�►�ali�+MiarrtiitG.o Y 'Dale: Signa C� 7 e, 7 -ti AOL fig 160, o"a 1 a \f All f e e 75- as - e , �r—`� '"`^`' b, X025 DC,T14- b W�ll MIN :XIJ�ING �hiD�P�G� Q' 1f2 AM WlM 4i*49:�h�KT�i4 �iRf�,oG.. 1 STAWf*=60 MOP "An I Sfnl 4 "W�VA 044900 &P. 11- C� a 44 --L MP - Vii♦ 11 ii i / 0�''P.+ccs'' 4W6 0-f �w so - \ Nt.W 't" lop9fr 7- 1 ALS-- :`•;ti��i �= •".lr:�`.�. ° -•� ".y�, •� , � f � to ' s ":-ate..,-. t e µ`rw4F ® _,'�a.'..'•�,x „.w - _ r .�Y. :,:. ; "'fir' . . �► Lx 71, .1.� A--z 4 N —,14 --V —'s, NOW- 6, . ,.. � „ •.. - 3dII�MlBAdJiR�G,t4dEY , �5 c,. #Y+'a'$ a �.. , s.. I Hao 1400�v�� R�� APPROVA,or DEPART NVtRONMENTAL fiES ix M , 'AGEMEN CORE REMEWERIPRI ►• i� %o� "IGNATURE 0000615239 DATF 4 Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 MIAMI SHORES VILLAGE NOTICE TO BUILDING DEPARTMENT OF EMPLOYMENT AS SPECIAL INSPECTOR UNDER THE FLORIDA BUILDING CODE I (We) have been retained by to perform special inspector services under the Florida Building Code at the 253 ne 104TH AVE MIAMI SHORES project on the below listed structures as of 05.0&14 (date). I am a registered architect or professional engineer licensed in the State of Florida. PROCESS NUMBERS: ❑ SPECIAL INSPECTOR FOR PILING, FBC 1822.1.20 (R4404.6.1.20) ❑ SPECIAL INSPECTOR FOR TRUSSES >35' LONG OR 6' HIGH 2319.17.2.4.2 (R4409.6.17.2.4.2) ❑ SPECIAL INSPECTOR FOR REINFORCED MASONRY, FBC 2122.4 (R4407.5.4) IX SPECIAL INSPECTOR FOR STEEL CONNECTIONS, FBC 2218.2 (R4408.5.2) ❑ SPECIAL INSPECTOR FOR SOIL COMPACTION, FBC 1820.3.1 (R4404.4.3.1) ❑ SPECIAL INSPECTOR FOR PRECAST UNITS & ATTACHMENTS, FBC 1927.12 (R4405.9.12) ❑ SPECIAL INSPECTOR FOR Note: Only the marked boxes apply. The following individual(s) employed by this firm or me are authorized representatives to perform inspection ALIOSMR GANEM 2 3. 4. *Special Inspectors utilizing authorized representatives shall insure the authorized representative is qualified by education or licensure to perform the duties assigned by the Special Inspector. The qualifications shall include licensure as a professional engineer or architect; graduation from an engineering education program in civil or structural engineering; graduation from an architectural education program; successful completion of the NCEES Fundamental Examination; or registration as building inspector or general contractor. I, (we) will notify Miami Shores Village Building Department of any changes regarding authorized personnel performing inspection services. I, (we) understand that a Special Inspector inspection log for each building must be displayed in a convenient location on the site for reference by the Miami Shores Village Building Department Inspector. All mandatory inspections, as required by the Florida Building Code, must be performed by the County. The Village building inspections must be called for on all mandatory inspections. Inspections performed by the Special Inspector hired by the Owner are in addition to the mandatory inspections performed by the Department. Further, upon completion of the work under each Building Permit I will submit to the Building Inspector at the time of final inspection the completed inspection log form and a sealed statement indicating that, to the best of my knowledge, belief and profetion'j,�lif ose portionsof the project outlined above meet the intent of the Florida Building Code and are in subsplans. StEngineerlArchitect ��NameALIOSKARGANEM * • L747: 05 �• A% •� 1r100111111110 MWM Address 1380 NE MIAMI GARDENS DR UNIT 205 Phone No. (786) 916-6546 NOTE: ALL SHEET MUST BE REVIEWED MIAMI-DADE COUNTY BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street (Coral Way) a Miami, Florida 33175-2474 • (786) 315-2100 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE AND/OR DEPARMENT OF ENVIRONMENTAL RESOURCES MANAGEMENT 0 ' ;c,0. 3 PROVIDE MUNICIPAL PROCESS NUMBER HERE Job Address o�5 3 / Contractor No. O z Z i Folio o o v 2 Last four (4) digits of Qualifier No. G W a 92 Contractor Name Lot Block 88 O a Subdivision PBpg zC Qualifier Name g v i Address City State _Zip Metes and bounds [ New Construction on [ ]Demolish 'Current use of property � �- F Vacant Land [ ] Shell Only LL W [ ] Iteration Interior [ ]Addition Attached W W [ Alteration Exterior [ ] Addition Detached Description of Work C [ ] Relocation of Structure [ ] Re -Roof'} 1E 2 [ ] Enclosure [ ] Foundation Only q. Ft. Units Floors Repair [ l P [ ]Tent [ ] Repair Due to Fire Value of Work . [ f] MBLD" [ ] Chg. Contractor Owner ��`� r y �r Address _S3�- a Category F [ ] Re -Issue a40JU [ ] MELE y [ ] Re -Stamp rn City Zip [ ] MLPG [ ] Revision W Phone Last four (4) digits of LU [ ] MMEC [ ] Not Applicable for 3 [ ] FIRE ¢ Fire Owner's Social Security No. �2' t .r u) Name ® t°JS �T Owner C z a cc to W W W Address C 7 �� PC Address ,� a !`�1` / City fes" ^ 'State Zip City State Na ¢ Fz Z as "` Phone �� � ' —1, � "? W _Zip Phone I am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible at the rate of $190 for the first hour g ¢ and $65 per each additional hour in addition to the review fees. Minimum charge one-hour. vays W � 1- Request: Date: N w W ¢ 2nd Request: Date: cc 31d Request: Date: z g 1 am requesting Optional Plan Review (OPR) to be scheduled as soon as possible at the rate of $75 for each discipline. a Additional review fees may apply. �O C � L 111 Request: Date: OE 2nd Request: Date: Ncc � LU 3'd Request: Date: 0 12301-192 6/10 BUILDING PERMIT CATEGORIES CATEGORY DESCRIPTION PERMIT TYPE BUILDING 01 GENERAL BUILDING -COMMERCIAL MBLD 02 SUB -GENERAL BUILDING -RESIDENTIAL MBLD 08 CANVAS AWNING MBLD 10 COMMUNICATION TOWER MBLD 15 DEMOLITION MBLD 29 METAL AWNING & STORM SHUTTER ' _` MBLD 48 SCREEN ENCLOSURES - MBLD 55 SWIMMING POOL MBLD 56 TENNIS COURTS (SURFACE PAVING) MBLD 86 TRAILER TIE DOWN MBLD 88 WALK-IN COOLER MBLD 91 MARINAS MBLD 92 LOW SLOPE APPLICATIONS (GRAVEL, SMOOTH MODIFIED, SINGLE PLY) MBLD 95 SHINGLES (ASPHALT, FIBERGLASS) MBLD 96 SHINGLES (METAL ROOFS/WOOD SHINGLES & SHAKE) MBLD X97 ' ' �'' S14d 2 VAPOR RECOVERY SYSTEM MBLD 99 SOIL IMPROVEMENT MBLD 0100 BULK STORAGE PROPANE TANK MBLD 0101 REMOVABLE STORM PANELS MBLD 0107 TILE ROOF MBLD 01•10. .., { , 'WATER MAIN MBLD 0111 '.' 61TF,;P-I%AhI MBLD ••INDOOR EVENT/EXHIBIT MBLD ELECTRICAL ° •' ..'D 04 FIRE ALARM SPECIALTY MELE 16 SPECIALTY WIRING MELE 38 GENERATORS MELE LPGX 01 LIQUEFIED PETROLEUM GAS MLPC 02 MISCELLANEOUS 04 LIQUEFIED PETROL. GAS/STATE MLPG MECHANICAL 09 ABOVE/BELOW GROUND TANKS/PUMPS & POLLUTANT STORAGE SYSTEM MMEC 38 COMMERCIAL HOODS MMEC 43 FIRE CHEMICAL MMEC 46 SPRAY BOOTHS MMEC 48 SMOKE CONTROL MMEC 52 RESIDENTIAL ELEVATOR MMEC FIRE 32 FIRE SPRINKLER FIRE a0/V o NOTE: ALL SHEET MUST BE REVIEWED MIAMI-DADE COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES Herbert S. Saffir Permitting and Inspection Center 11805 SW 26th Street (Coral Way) • Miami, Florida 33175-2474 • (786) 315-2000 APPLICATION FOR MUNICIPAL PERMIT APPLICANTS THAT REQUIRE PLAN REVIEW FROM MIAMI-DADE FIRE RESCUE AND/OR ENVIRONMENTAL SERVICES PROVIDE MUNICIPAL PROCESS NUMBER HERE Job Address (� Contractor No. a� 0 � Folio oc z 02 Last four (4) digits of Qualifier No. 0 qa Contractor Name Lot Block z Qualifier Name 000 g Subdivision PBpg a n z Address City State _Zip Metes and bounds [ ] New Construction on Vacant Land [ ] Demolish Current use of property [ ] Shell Only W [ eration Interior [ ] Addition Attached Description of Work 1 w � [ Alteration Exterior [ ]Addition Detached � uj0 [ ] Relocation of Structure [ ] Re -Roof Sq. Ft. ( Units Floors M 2 [ ] Enclosure [ ] Foundation Only [ ] Repair Tent [ ] �j- v ;z. [ ] Repair Due to Fire Value of Work [BLD* [ ] Chg. Contractor Owner CGt- .D Address LUS Category y F [ ] Re -Issue w 2 [ ] MELE y [ ] Re -Stamp city Zip [ ] MLPG [ ]RevisionW Phone "z x� G Last four (4) digits of a [ ] MMEC [ ] Not Applicable for 3 [ ] FIRE °C Fire 0 Owner's Social Security No. �7 l L z Name �� Owner °g 8W o(.�Sr 0 � 1 - z a Address W W Address City 0(i�1v ���tate Zip �� City State oa W Y f -z z 0.0 Phone �� "� �� I CJ czi w _Zip Phone I am requesting a Special Request Plan Review (SRI) to be scheduled as soon as possible at the rate of $190 for the first hour and $65 per each additional hour in addition to the review fees. Minimum charge one-hour 12 vav� W 111 Request: Date: U) LLW Q 2"d Request: Date: Td Request: Date: 1 am requesting Optional Plan Review (OPR) to be scheduled as soon as possible at the rate of $75 for each discipline. a a Additional review fees may apply. 0 0 3 1 � Request: Date: o 2"d Request: Date: LUIx 31dRequest: Date: 12301-192 6/13 BUILDING PERMIT CATEGORIES r CATEGORY DESCRIPTION BUILDING PERMIT TYPE 01 GENERAL BUILDING—COMMERCIAL MBLD 02 SUB—GENERAL BUILDING—RESIDENTIAL MBLD 08 CANVAS AWNING MBLD 10 COMMUNICATION TOWER MBLD 15 DEMOLITION MBLD 29 METAL AWNING & STORM SHUTTER MBLD 48 SCREEN ENCLOSURES MBLD 55 SWIMMING POOL MBLD 56 TENNIS COURTS (SURFACE PAVING) MBLD 86 TRAILER TIE DOWN MBLD 88 WALK-IN COOLER MBLD 91 MARINAS MBLD 92 LOW SLOPE APPLICATIONS (GRAVEL, SMOOTH MODIFIED, SINGLE PLY) MBLD 95 SHINGLES (ASPHALT, FIBERGLASS) MBLD 96 SHINGLES (METAL ROOFS/WOOD SHINGLES & SHAKE) MBLD 97 STAGE 2 VAPOR RECOVERY SYSTEM MBLD 99 SOIL IMPROVEMENT MBLD 0100 BULK STORAGE PROPANE TANK MBLD 0101 REMOVABLE STORM PANELS MBLD 0107 TILE ROOF MBLD 0110 • .- - WATERMAIN MBLD 0111 SITE PLAN MBLD U11r- ; INDOORVENT/EXHIBIT MBLD ELECTRICAL 04FIRE ALARM SPECIALTY MELE 16 a SPECIALTY WIRING MELE 38 GENERATORS MELE LPGX 01 .LIQUEFIED PETROLEUM GAS MLPG 02 MISCELLANEOUS 04 LIQUEFIED PETROL. GAS/STATE MLPG MECHANICAL 09 ABOVE/BELOW GROUND TANKS/PUMPS & POLLUTANT STORAGE SYSTEM MMEC 38 COMMERCIAL HOODS MMEC 43 FIRE CHEMICAL MMEC 46 SPRAY BOOTHS MMEC 48 SMOKE CONTROL MMEC 52 RESIDENTIAL ELEVATOR MMEC FIRE 32 FIRE SPRINKLER FIRE