Loading...
RF-14-1978BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 ❑BUILDING ❑ ELECTRIC 0 ROOFING SEP I IM FBC 20L% Master Permit No. r-1 � � q "9 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING ❑ MECHANICAL [—]PUBLICWORKS ❑ CHANGE OF [:]CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 967 NE 99 STREET City: Miami Shores County: Miami Dade Zia• Folio/Parcel#: 11-3206-034-0270 Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: � Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Titleholder): GEORGE LeVasser Phone#: 305-888-4611 Address: 967 NE 99 STREET City: MIAMI SHORES State: FL Z(p: 33138 Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: WHITE SEAL INC Phone#: 954-922-7383 Address: 2015 COOLIDGE STREET City: HOLLYWOOD State: FL Zlp: 33020 Qualifier Name: ROBERT ETHRIDGE Phone#: 954-536-7049 State Certification or Registration #: CCC056367 Certificate of Competency #: DESIGNER: Architect/Engineer: 0 State: Value of Work for this Permit: $ Square/Linear Footage of Work: 400 Type of Work: ❑ Addition ❑ Alteration ❑ New M Repair/Replace Description of Work: REROOF FLAT ROOF Zip: ❑ Demolition Specify color of color thru tile: ,�\ Submittal Fee $ s Permit Fee $ C0® ° CCF $ (� CO/CC $ Scanning Fee $ Radon Fee $'Z DBPR $ > Notary Technology Fee $ ° �4 ® Training/Education Fee $ 0 Double Fee $ OStructural Reviews $ � Bond $ R • 00 TOTAL FEE NOW DUE $ ° 93 (Revised02/24/2014) S �J-jc) Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charge Signature OWNER or AGENT The foregoing instrument was acknowledged before me this etlw dayof_ 1rAe !4C: 20 0! by e, SSe� who is personally known to me or who has produced FL L as identification and who did take an oath. NOTARY Sign:_ Print: Seal: Nary Publl9 81919 at Flodda . canons Noun M SII' 46430 APPROVED BY 1-Vllll 11 (Revised02/24/2014) d. Signature CONTRACTOR The foregoing instrument was acknowledged before me this day of �31-®it-"ber , 20 6- by ell�obed - 'r'who is er o *- 0 lue me or who has produced identification and who did take an oath. NOTARY PUBLIC: Sign: Print:_ Seal: , N Notary public Stale ''ry'v' a Cadent Nelson Flodde .�� MY Comm Expi►es 05 03/02/2017884308 Plans Examiner Structural Review as Zoning Clerk STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD 1940 NORTH MONROE STREET TALLAHASSEE FL 32399-0783 ETHRIDGE, ROBERT FONTANA WHITE SEAL INC 2015 COOLIDGE STREET HOLLYWOOD FL 33020 Congratulations! With this license you become one of the nearly one million Floridians licensed by the Department of Business and Professional Regulation. Our professionals and businesses range from architects to yacht brokers, from boxers to barbeque restaurants, and they keep Florida's economy strong. Every day we work to improve the way we do business in order to serve you better. For information about our services, please log onto www.myfloridalicense.com. There you can find more information about our divisions and the regulations that impact you, subscribe to department newsletters and learn more about the Department's initiatives. Our mission at the Department is: License Efficiently, Regulate Fairly. We constantly strive to serve you better so that you can serve your customers. Thank you for doing business in Florida, and congratulations on your new license! DETACH HERE RICK SCOTT, GOVERNOR (850) 487-1395 KEN LAWSON, SECRETARY STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION CONSTRUCTION INDUSTRY LICENSING BOARD CCCO56367 The ROOFING CONTRACTOR Named below IS CERTIFIED Under the provisions of Chapter 489 FS. Expiration date: AUG 31, 2016 mq i m. nnmai)n1A IIISPI AY AR RFnI IIRFn RY I AW SEO # L1408030003109 I BROWARD COUNTY LOCAL BUSINESS TAX RECEIPT 115 S. Andrews Ave., Rm. A-100, Ft. Lauderdale, FL 33301-1895 — 954-831-4000 VALID OCTOBER 1, 2014 THROUGH SEPTEMBER 30, 2015 DBA: Receipt#:o WHITE SEAL INC :ROOFING/SHEET METAL CONTRACTOR Yp Business Name: Business T e: R (ROOFING CONTR) Owner Name: ROBERT ETHRIDGE Business Opened:io/01/2004 Business Location: 2015 COOLIDGE ST State/County/Cert/Reg:CCc056367 HOLLYWOOD Exemption Code: Business Phone: 954-922-7383 'I Rooms Seats Employees Machines Professionals 10 For Vending Business Only � Number of Machines: Vendino Tvoe: Tax Amount Transfer FeeNSF FeePenalty Prior Years Collection Cost Total Paid 27.00 0.00 0.00 0.00 0.00 0.00 7.1.00 THIS RECEIPT MUST BE POSTED CONSPICUOUSLY IN YOUR PLACE OF BUSINESS THIS BECOMES A TAX RECEIPT This tax is levied for the privilege of doing business within Broward County and is non -regulatory in nature. You must meet all County and/or Municipality planning WHEN VALIDATED and zoning requirements. This Business Tax Receipt must be transferred when the business is sold, business name has changed or you have moved the business location. This receipt does not indicate that the business is legal or that it is in compliance with State or local laws and regulations Mailing Address: ROBERT ETHRIDGE 2015 COOLIDGE ST HOLLYWOOD, FL 33020 Receipt #1CP-13-0001317 Paid 08/21/2014 27.00 i ! 2014 -2015 -- - Qbf1\ANAt2nf�f111sun I1I+I1-1 olii +mmocC TAV bC/+C11`fT CERTIFICATE OF LIABIL producer. Lion Insurance Company 2739 U.S. Highway 19 N. Holiday, FL 34691 (727) 938-5562 Insured: South East Personnel Leasing, Inc. & Subsidiaries 2739 U.S. Highway 19 N. Holiday, FL 34691 with respect to which this certificate maybe issued or may pertain, the insurance afforded by the limits shown may have been reduced by paid claims. "TR IISRI NSRD Type of Insurance Commercial General Liability Claims Made 13 Occur eral aggregate limit applies per: Policy 11 Prooa ❑ LOC LIABILITY Any Auto All Owned Autos Scheduled Autos Hired Autos Non -Owned Autos Policy Number -I 1 1 9/9/2014 This Certificate Is Issued as a matter of Information only and confers no rights upon the certificate Holder. This Certificate does not amend, extend or alter the coverage afforded by the policies below. Insurers Affording Coverage =C # Insurer A: Lion Insurance Company 1 11075 L9 described herein is subject to all the terms, mduslons, and conditions of such policies. Aggregate C.J.r/II .- ' Date Limits Each Occurrence IDamage to rented premises (EA I oearrencs) Med Exp Personal Adv Injury General Aggregate Products - Comp/Op Agg Combined Single Llmlt (EA Accident) Bodily Injury (Per Person) Bodily Injury (Per Accident) Property Damage (Per Accident) EXCESS/UMBRELLA LIABILITY Each Occurrer= Occur 13Claims Made Aggregate Detluouble A Workers compensation and WC 71949 01/01/2014 01/01/2015 x we Statu- OTH- Employers' Liability I tory Limits ER Any proprietor/partner/executive officer/member E.L. Each Accident 51,000.000 excluded? NO E.L. Disease - Ea Employes $1,000,000 If Yes, describe under special provisions below. E.L. Disease - Policy Limits $1,000,000 Other I Lion Insurance Company Is A.M. Best Company rated A- (Excellent). AMB # 12616 1 Descriptions of OperationsILocaUonsiVehlcloWExcluslons added by Endorsement/Special Provisions: Client ID: 92-68-009 Coverage only applies to active employee(s) of South East Personnel Leasing, Inc. & Subsidiaries that are leased to the following "Client Company": White Seal Inca dba Robert Fontana Ethridge Coverage only applies to Injuries incurred by South East Personnel Leasing, Inc & Subsidiaries active employee(s), while working In: FL Coverage does not apply to statutory employee(s) or Independent contractor(s) of the Client Company or any other entity. A list of the active employee(s) leased to the Client Company can be obtained by faxing a request to (727) 937-2138 or by calling (727) 938-5562. "ect Name: ISSUE 09-09-14 (TLD) 10050 NE 2ND AVE MIAMI SHORES, FL 33138 brlould any or me above descriced policies Do cancelled before the expiration dere thereof, the Issuing insurer will endeavor to mail 30 days written notice to the certificate holder named to the left, but failure to do so shall impose no obligation or liability of any Idnd upon the insurer, its agents or representatives. E2 ACORD- CERTIFICATE OF LIA91LITY INSURANCE 79/10/2-014 DAT ) PRODUCER Pettineo Insurance Agency, Inc 2430 E. Commercial Blvd. Ft. Lauderdale, FL 33308 954-493-9424 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS -NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. INSURERS AFFORDING COVERAGE NAIL# INSURED White Seal, Inc. Bob Ethridge 2015 Coolidge Street Hollywood, FL 33020 1954-922-7383 INSURER A: Western World Insurance Co. INSURER B: INSURER C: INSURER D: INSURER E• cnvFRAaes THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERF INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAYHAVE BEEN REDUCED BY PAID CLAIMS. MR LTR D'LPOLICY TYPE OF N NC POLICY NUMBER EFFECTIVE ATE MMIDDIYY POLICY EXPIRATION DATE MMIOO LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,00p,000 PREMISES Ea oomvence $ 1001 ON ]� COMMERGIAL GENERAL LIABILITY CLAIMSMADE tiJ OCCUR MEOEXP (Any one person) $ 10,000 PERSONAL &ADV INJURY $ 1,000,000 A NPPS149613 4/17/2014 4/17/2015 GENERAL AGGREGATE $ 2 Q O0 G&nAGGREGATE LIMIT APPLIES PER PRODUCTS -COMPIOPAGO S 2,000,000 X1 POLICYF-j JECT LOC AUTOMOIStE LIABILITY COMBINED SINGLE LIMIT $ ANYAUTO (Ea --dent) BODILY INJURY $ ALL OWNED AUTOS SCHEOULEDAUTOS (Perperson) BODILY INJURY $ HIRED AUTOS NON-OWNEDAUTOS (Peracddetd) PROPERTY DAMAGE $ (Peracdd-1) GARAGE LIABILII'Y AUTO ONLY -EAACCIDENT $ ANYAUTO OTHERTHAN EAACC $ $ AUTOONLY: AGG EXCESSIUMBRELLA LIABILITY EACH OCCURRENCE $ OCCUR CICLAIMSMADE AGGREGATE $ h:OF.000TIRLG $ tFIrNjtDN $ S WORXERSCOMPENSATIONAND ITA 11- TWRYLIMi S OFR EMPLOYERS LIABILITY £.L. EACH ACCIDENT _ $ ANY PRCPRIETCRIPARTNERIEXECUTWE EL - DISEASE - EA EMPLOYE $ CPMERAISM85R EXCLUDED? Uyea, describe wider SPECIAL PROVISIONS botaw E L. DISEASE - POLICY LIMIT $ OTHER DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT 1 SPECIAL PROVISIONS Roofing Miami Shores Village 10050 NE 2nd Avenue Miami Shores, FL 33138 TION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION ()ATF THFRFOF, THF•L4SIJINT+ WCI IRFR WII I FNnFAVnR TO MAII, nAYR WRITTFN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO DO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON THE INSURER, ITS AGENTS OR ACORD25(2001108) /##r OACORD CORPORATION 1988 4,/qr 177? i A. Tomassi Roof Testing, Inc. f ����►���� 5451 NW 2e Street, Suite # 3 Margate, Florida 33063 TAS —106 Tel. 954 — 979 —1180 Fax. 954 —979 —1182 Roof Tile Static Uplift Test Report Test Date: October 10th, 2014 Project: Two (2) courses of tile along tie-in, of at flat roof area 967 NE 99 St, Miami Shores, Florida Contractor: White Seal Roofing Permit #: RF — 9 —14 — 1978 Roof Pitch: 3 Y2" Tile Installation Date: 10/9/2014 Attachment Method: Mortar & Adhesive set Tile Type: Altusa All testing is in strict accordance with the 2010 Florida Building Code, High Velocity Hurricane Zone Testing Application Standard (TAS) 106 Each Test location was pulled using a Imada Force Gauge to a minimum of 35 lbs. TEST SUMMARY: Roof Area Total # of Tests # of Tests Passed % Passed Field N/A N/A N/A Corner N/A N/A N/A Perimeter 2 2 100% FE (None) N/A N/A N/A Ridge (None) N/A N/A N/A TEST RESULTS: PASSED See Attached Sketch For Further Details. Report Reviewed by: Dominick Scarfo, ARO 10248 Dade County Certified Testing Agency # 12-0710.03 Revises: # 07-0720.04 Testing * Design Specifications * Management * Litigation * Quality Assurance 2' Total Approximated 30 S.F. TAS -106 Test Locations All Dimensions are Approximate T = Tested Tile and Passed F = Tested Tiled and Failed H = Hip Tile Tested and Passed R = Ridge Tile Tested and Passed --I N Project: 967 NE 99 St, Mia. Shores, Fl. Certificate of Calibration # KELC-279964 Kimball Electronic Laboratory, Inc. Precision Measurement Equipment Specialists I�aI�I�SIN��Y�6111 Purchase Order # A. TOMASSI ROOF TESTING, INC. 5451 NW 24 STREET #3 MARGATE FL 33063 Manufacturer: IMADA Cal Date: 24 -Sep -14 Model Number. DPSH-440 Cal. Due Date: 24 -Dec -14 Part Number. DPSH-440 Cal. Interval: 3 MONTHS Range: 0-440 LBS Received: IN TOLERANCE Calibration Result: PASS Serial Number. 199171 Environmental Conditions: 77 DEG F / 58 % RH Customer I. D.: N/A Performed By: JULIO Cust. Barcode: NIA GARCIA Cust. Dept.: N/A Procedure: SYN 156 Specifications: +/-.2 LBS Cal Location: ON-SITE This is to certify that the above Fled instrument meets or exceeds all specifications as stated in the referenced procedure at the points tested (unless otherwise noted). It has been calibrated using measurement standards traceable to the National Institute of Standards and Technology (NIST), or to NIST accepted intrinsic standards of measurement, or derived by the ratio type of self-callbration techniques. This calibration is in accordance with Kimball Electronic Laboratory, Inc Quality Assurance Manual. KELI's Quality system is AXA-Accxedcted to ISO/IEC-17025:2005 and compliant with PAL -STD -45662A and ANSUNCSL Z540.3-2006. TURS when applicable are greater than or equal to 4:1; with expanded uncertainty used to calculate the Test uncertainty Ratio, with a coverage factor of K--2 at a confidence level of approximately 85%, unless otherwise noted. Any number of factors may cause the calibration item to drift out of calibration before the recommended interval has expired. THIS UNIT WAS FOUND TO BE IN TOLERANCE AT THE TIME OF CALIBRATION. PERFORMED ROUTINE CAL. NO ADJUSTMENTS REQUIRED Company I.D. Manufacturer ModeliPN Description Serial Number Last Cal. Cal. Due Date KIM001 447 AKO TSD 2052 -SB DEAD WEIGHT SYSTEM 624 30 -Sep -13 30 -Sep -14 Certified by: Quality Assuranlce: JULIO JAVIER e;� GARCIA 24 -Sep -14 6:14:20 AM BALCEIRO 26 -Sep -14 8:14:37 AM This report may not be reproduced, except in full, unless permission for the publication of an approved abstract Is obtained In writing from KELI Labs., Inc. Kimball Electronic Laboratory, Inc. - 8081 W. 21st Lanb '- Hialeah, F�. 33016 Tel: 305-822-5792 - Toll Free: 800-393-1094 Fax 305-362-3125 - Web: www.kefilabs.com :. F1 AT 101 SEP A © 2014 Y: Florida Building Code 2010 Edition High Velocity Hurricane Zone Uniform Pennit Application Form INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: ATT, Front Page Specft System Description Speoiftc System Limitations General Umitaeions Applicable Detail Drawings Deslgn Calculations per Chapter 16, or RAS 129 0000 . sees 0000.. . 11 ee 0 00 606060 0000.. 0000 000 0 6.. 0000. 0s: 000• 00660 0000.. 0000 00600 • • 0000 6666 66 , ::sees 0000.. :. . . , 0000.. • 0 0000.. • • 660600 27 or • • 0 • 0060 Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low Sloped Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, identify as -NA') System Manufacturer: IukG NOA No.: %S - Oy2A A. 14 Design Wind Pressures, From RAS 128 or Calculations: Pmax1: - 3q .1 Pmax2: - 66. t Pmax3: - %00.1 Max. Design Pressure, From the Specific NOA System: VS F Deck: Type: Gauge/Thickness: 3 Slope: Anchor/Base Sheet & No. of Ply(s):Sip Anchor/Base Sheet Fastener/Bonding Material: VIVA -,A.%tAe c% v Insulation Base Layer: 29N%4--'T-r Base Insulation Size and Thickness: :l• Ig (4 X y� Base Insulation Fastener/Bonding Material: Hod � stale 1 � . Top Insulation Layer: J.i( Top Insulation Size and Thickness: m t A Top Insulation Fastener/Bonding Material: A( q Field: -�_" oc @ Lap, # Rows #- C)�" oc Perimeter: b " oc @ Lap, # Rows `i @ --k-- oc Corner: to " oc @ Lap, # Rows 14 @ oc Number of Fasteners Per Insulation Board No a- fksvvtoxl. - Field: Perimeter Corner Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. Base Sheet(s) & No. of Ply(s):-minaSov�} Base Sheet Fastener/Bonding Material: t ._. " kc AsphaAs�h C Ply Sheet(s) & No. of Ply(s): " :pe. Ply Sheet Fastener/Bonding Material: "C'k- F�Be�lnc�i� Top Ply: OC. f- Top Ply Fastener/Bonding Material: k-kok- Surfacing: l�cc�uta )b�0�1. 0000 • tho�►.F.e d RC Parapet • :..' 0000.. k:z1 p\�cS ::::Weight ... • 0000.. ►•S Po\y3.so '. 0000.. .. - 'lS1b baba .> 00 .... 00 00 . ••• 6 00000 L 000000 WODO :0so • • . ' • •' • • 0000. Height :0006: • on • 6666 6000 SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner and the contractor. The owner's initial in the adjacent box indicates that the item has been explained. C40- 1. Aesthetics -Workmanship: The workmanship provisions of Section R4402 are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. CciA-�2. Renalling Wood Decks: When replacing roofing, the existing wood roof deck may have to be renal ed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system.) 3. Common Roofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing work to be performed. 4. Exposed Ceilings: Exposed, open beam ceilings are where the underside of the roof decking can a viewed from below. The owner may wish to maintain the architectural appearance, therefore, roofing nail penetrations of the underside of the decking may not be acceptable. This provides the option of maintaining this appearance. 5. Ponding Water: The current roof system and/or deck of the building may not drain well and m9y cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Ponding may shorten the life expectancy and performance of the new roofing system. Ponding conditions may not be evident until the original roofing system is removed. Ponding conditions should be corrected. 6. Overflow scuppers (wall outlets): It is required that rainwater flow off so thatthe rodf is apt overloaded from a build up of water. Perimeter/edge walls or other roof extensions mayblgek tPis dischasge if overflow scuppers (wall outlets) are not provided. It may be necessary to install oyQgLM scupperso aw,,ordance with the requirements of Sections R4402, R4403 and R4413. • • •; •. 7. Ventilation: Most roof structures should have some ability to vent natural alodol ao throug4•the interior 6f the structural assembly (the building itself). The existing amount of attic ventilatiorrshali potb2. reduced. It may be beneficial to consider additional venting which can result in extending h3pservice MOdf the roof. • Exception: Attic spaces, designed by a Florida licensed engineer or registered arc ' ct tg eliptigate thlb attic venting, venting shall not be required.. .. .... Owner's/Age is Signature Date Contractor's Signature 96 -4 AJ 99'* S4 -e Property Address IMAM W .fees, Permit Number COUNTY MIAMI -DARE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION D"ION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GAF Ruberoie Modified Bitumen Roof System for Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and - • following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein."" .. . 0 06 RENEWAL of this NOA shall be considered after a renewal application has been filed "these has %c6 o change in the applicable building code negatively affecting the performance of this produe1k • • • • TERMINATION of this NOA will occur after the expiration date or if there has been a ft-wisoik or cl*arigein the materials, use, and/or manufacture of the product or process. Misuse of this NOA as aaek1seme4f 8f by product, for sales, advertising or any other purposes shall automatically terminate this NO*. Pdilure to comply with any section of this NOA shall be cause for termination and removal of NOA. • • :000:0 ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, P•lor06 and followed 0000 by the expiration date may be displayed in advertising literature. If any portion of the NOA'is displaye.(t then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09-0224.01 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 13-0424.14 t�nnht�•tuweCout�nr Expiration Date: 11/06/14 1APPROVED1 Approval Date: 10/31/13 Page 1 of 29 0000.. 0000.. 0000.. 0000. 0000. 0000.. 0000.. .0000. ROOFING SYSTEM APPROVAL Category Roofing Sub-Catemory: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Matrix"" 102 SBS 5 gallons ASTM D3019 Fiber reinforced rubberized cold -applied Membrane Adhesive adhesive for modified bitumen roof systems. GAFGLAS®#75 39.37' ASTM D4601 Type II asphalt impregnated and coated Base Sheet (1 meter) Wide glass mat base sheet. GAFGLASO #80 Ultima' 39.37' ASTM D4601 Type H asphalt impregnated and coated, Base Sheet (1 meter) Wide fiberglass base sheet. GAFGLAS® F1exPly"" 6 39.37' ASTM D2178 Type VI asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS® Ply 4 39.37' ASTM D2178 Type IV asphalt impregnated glass felt (1 meter) Wide with asphalt coating. GAFGLAS® Mineral 39.37' ASTM D3909 Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet (1 meter) Wide surfaced with mineral granules. GAFGLAS® EnergyCap"" 39.37' ASTM D3909 Asphalt coated, glass fiber mat cap sheet BUR Mineral Surface Cap (1 meter) Wide surfaced with mineral granules with Sheet factory applied EnergyCote'.- GAFGLAS® Stratavene 39.37' ASTM D4897 Fiberglass base sheet coated on both sides Eliminator Perforated (1 meter) Wide with asphalt. Surfaced on the bottoffi st e Venting Base Sheet with mineral granules embedded in. asphaltic coating with %t0on ' GAFGLAS® Stratavene 39.37' ASTM D4897 perforations. 669:09 • A nailable, fiberglass basewheet cogted„Qg Eliminator Perforated (1 meter) Wide both sides with asphalt R44ced on the Nailable Venting Base bottom side with minepA%TlSules 0""• Sheet embedded in asphaltic tbafi$ . 00 0. 0 Ruberoid® SBS 39.37' ASTM D6164 Non -woven polyester Mfgated with 0 Heat -Weld Smooth (1 meter) Wide polymer -modified aspliklt aqd smodo"" Ruberoid® SBS 39.37' ASTM D6164 surfaced. a 000 ' . 0 • • Non -woven polyester mat coated with e • Heat -Weld" Granule (1 meter) Wide polymer -modified asphalt and surfaced with mineral granules. RoofMatchm 107 sq. ft. ASTM D6164 Non -woven polyester mat coated with SBS Modified Granular (9.9 m2) SBS polymer -modified asphalt and surfaced with colored mineral granules. Ruberoid` SBS 39.37' ASTM D6164 Non -woven polyester mat coated with fire Heat -Weld" 170 FR (1 meter) Wide retardant polymer -modified asphalt and surfaced with mineral granules. NOA No.: 13-0424.14 Muuain,cou�rnr Expiration Date: 11/06/14 "JAPPROVED1 Approval Date: 10/31/13 Page 2 of 29 6090.. 009... 6666.. 6666. x6666 6666.. 6666.. 6666.. Test Product Product Dimensions Specification Description Ruberoid® SBS 39.37" ASTM D6164 Non-woven polyester mat coated with Heat-Weld' Plus (1 meter) Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid' SBS 39.37" ASTM D6164 Non-woven polyester mat coated with fire Heat-Weld Plus FR (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoie EnergyCap- 39.37" ASTM D6164 Non-woven polyester mat coated with fire SBS Heat-Weld"° Plus FR (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoid® SBS 39.37" ASTM D6163 Non-woven polyester mat coated with Heat-Weld's 25 (1 meter) Wide polymer-modified asphalt and smooth surfaced. Ruberoid® Mop Granule 39.37' ASTM D6164 Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid® Mop Smooth 39.37' ASTM D6164 Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and smooth surfaced. Ruberoid® Mop Plus 39.37' ASTM D6164 Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and surfaced with mineral granules. Ruberoid® Mop 170FR 39.37' ASTM D6164 Non-woven polyester mat coated with fire (1 meter) Wide retardant polymer modified asphalt and surfaced with mineral granules. Ruberoid® Mop FR 39.37' ASTM D6164 Non-woven polyester mat coated with fire (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules. . 9 9. Ruberoie Torch Smooth 39.37' ASTM D6222 Non-woven polyester jnat coated wick• • (1 meter) Wide APP modified asphalt'and smooth : Ruberoid® Torch Granule 39.37' ASTM D6222 .90. surfaced. 6 • • • • • Gone Non-woven polyester ftnt'b'ated with' (1 meter) Wide APP modified asphalt atilt Go :.00:0 surfaced with mineral nuIjs ..... RuberoieEneraCap- 39.37' ASTM D6222 APP modified cap men Vr;:;with ftlesah' Torch Granule FR (1 meter) Wide grade bottom surface apd.%mineral - granular top surface coated Ah facIg" applied EnergyCote7. • • 0 Ruberoid®EnergyCap- 39.37' ASTM D6222 APP modified cap memiftne'with a tarcc* Torch Granule Plus FR (1 meter) Wide 6666 grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote'". RoofMatch7 107 sq. ft. ASTM D6222 Non-woven polyester mat coated with APP Modified Granular (9.9 m2) APP polymer-modified asphalt and surfaced with colored mineral granules. Ruberoid® Torch FR 1 meter ASTM D6222 Non-woven polyester mat, coated with fire (39.37') Wide retardant asphalt modified bitumen membrane with granule surface. NOA No.: 13-0424.14 ruar+i page -F-I rir Expiration Date: 11/06/14 "' Approval Date: 10/31/13 Page 3 of 29 6090.. 009... 6666.. 6666. x6666 6666.. 6666.. 6666.. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 4 of 29 Test Product Product Dimensions Specification Description Ruberoie 20 1 meter ASTM D6163 SBS modified asphalt base sheet reinforce (39.37") Wide with a glass fiber mat. Ruberoie 30 1 meter ASTM D6163 Non -woven fiberglass mat coated with (39.37") Wide polymer modified asphalt and surfaced with mineral granules. Ruberoie 30 FR 1 meter ASTM D6163 Non -woven fiberglass mat coated with fire (39.37") Wide retardant, polymer -modified asphalt and surfaced with mineral granules. Ruberoie EnergyCap- 30 1 meter ASTM D6163 Non -woven fiberglass mat coated with fire FR SBS Membrane (39.37") Wide retardant, polymer -modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Ruberoie Dual FR 39.37" (1 meter) ASTM D6162 Non -woven polyester and fiberglass mat Wide coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. Topcoat® Elastomeric 1, 5 or 55 gallons ASTM D6083 An acrylic, water based elastomeric Roofing Membrane membrane system designed to protect various types of roofing surfaces. Topcoat® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer used to block asphalt bleed -through. Topcoat' 5 gallons ASTM D6083 Solvent based sprayable thermoplastic Surface Seal SB rubber sealant designed to protect and restore aged roof surfaces- and to increase a roofs reflectivity. FireOut7 Fire Barrier 5, 55 gallons Proprietary Low VOC, water-based fire barrier Coating coating. VersaShiele 42" x 100' rolls ASTM D226 Non -Asphaltic, fire resistant fiberklassu Fire -Resistant Roof Deck based underla ent..see* • Protection 00 • 6' 906.96 .... 0000*0 6690 • ...... 669. •96666 • • • •9666• 6 • • • • 9.69 00 0 NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 4 of 29 APPROVED INSULATIONS: Product Name EnergyGuardT" Polyiso Insulation EnergyGuard7 RA Polyiso Insulation EnergyGuard7 RN Polyiso Insulation EnergyGuarC Perlite Recover Board EnergyGuard7 Perlite Roof Insulation EnergyGuardT" RA Composite Polyiso Insulation StructodeV High Density Fiber Board SecurocV Gypsum -Fiber Roof Board APPROVED FASTENERS: Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite roof board Polyisocyanurate/wood fiberboard or perlite composite High density wood fiber Gypsum board TABLE 3 Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF Blue Ridge FiberBoard, Inc. United States Gypsum Corp. Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Drill -Tec"" #12 Fastener Carbon steel fastener used Various GAF in steel or wood decks. 2. Drill-Tec#14 Fastener Carbon steel fastener used Various GAF in steel, wood or concrete decks. 3. Drill-TecT" XHD Fastener Carbon steel extra heavy Various GAF duty fastener used in steel 4. Drill -Tec AccuTrac® Flat decks. AZ -SS aluminized steel 3" x 3" : • bAF 000* Plate plate for use with Drill- " •.:..• ` ...... Tec"" #12 Fastener, Drill- 0*0 TM 000000 •+.; Tec #14 Fastener and 6046 4 Drill-TecT" #15 Fastener. ` • • • • ` ' • :" • 5. Drill -Tec"" ASAP 3S Drill -Tec"" #12 fastener Various • •: "* F ."" • "� ` ` with Drill-TecT" 3" • • " "" `� �' Standard Steel Plate. : • �: `: .... a • 6. Drill -Tec"" AccuTrac® Galvalume Steel plate for 3" x 311F :" Recessed Plate use with Drill-TecT"° •.. • . • • • * • g o e, • fasteners. see* 7. Drill-TecT" 3" Steel Plate Round galvalume steel 3" GAF stress plate for use with Drill -Tec"" fasteners. 8. Drill-Tec"m 3" Standard Round galvalume plated 3" GAF Steel Plate steel stress plate with reinforced ribs for use with Drill-TecT" fasteners. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 5 of 29 APPROVED ASSEMBLIES Membrane Type: SBS Deck Type 1I: Wood, Insulated Deck Description: 19/32 1 or greater plywood or wood plank System Type A(1): Anchor sheet mechanically fastened, all layers of insulation adhered with approved asphalt. All General and System Limitations shall apply. Fire Barrier: FireOut"' Fire Barrier Coating, VersaShieie Fire -Resistant Roof Deck Protection (optional) or SecurocV Gypsum -Fiber Roof Board. Anchor sheet: GAFGLAS® #80 Ultima"' Base Sheet, GAFGLAS® Stratavene Eliminator" Nailable Venting Base Sheet, Ruberoid® 20, Ruberoid® SBS Heat -Weld"' Smooth or Ruberoid® SBS Heat -Weld' 25 base sheet mechanically fastened to deck as described below. Fastening GAFGLAS® Ply 4, GAFGLAS® FlexPlyT" 6, GAFGLAS® #75 Base Sheet or any Options: of above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure —45 psf, See General Limitation #7) GAFGLAS® Ply 4, GAFGLAS® F1exPly"' 6, GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT" #12 Fastener, Drill-Teo`m #14 Fastener or Drill-TecT' XHD Fastener and Drill -Teo`" 3" Steel Plate, Drill - Tec"' AccuTraco Flat Plate or Drill -Tec"' AccuTrace Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf, See General Limitation #7) .. •. GAFGLAS® F1exPly"' 6, GAFGLAS® #75 Base Sheet or any of'ab� r✓eoanchol • sheets attached to deck with approved annular ring shank nails JU japs at g.;..' fastener spacing of 9" o.c. at the 4" lap staggered and in two rows•9;;q'C. in the • field. 6000 . • (Maximum Design Pressure 52.5 psf, See General Limitation M • • •s•• GAFGLAS® #80 Ultima."m Base Sheet, Ruberoie 20, Ruberoid® •]K+d%SfnootAme•• sheet attached to deck with approved annular ring shank nails and &kWws at a • fastener spacing of 9" o.c. at the 4" lap staggered and in two row9009" o.e in tit...:. field. • (Maximum Design Pressure —60 psf, See General Limitation #7)" ' •; GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill -Tec" #12 Fastener, Drill-Tec#14 Fastener or Drill-Teo"m XHD Fastener and Drill -Tec"' 3" Steel Plate, Drill -Tec"' AccuTraco Flat Plate or Drill-Tec"m AccuTrace Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 7 of 29 Any of above anchor sheets attached to deck approved annular ring shank nails and 3" inverted Drill-Tec"m insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above anchor sheets attached to deck with Drill-Tec"m #12 Fastener, Drill-Teo`m #14 Fastener or Drill -Tec'' XHD Fastener and Drill-Tec"g 3" Steel Plate, Drill -Tec"" AccuTrace Flat Plate or Drill -Tec' AccuTrace Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/fe EnergyGuarC Polyiso Insulation, EnergyGuard7 Polyiso RA Insulation, EnergyGuard7 Polyiso RN Insulation, EnergyGuard7 RA Composite Polyiso Insulation Minimum 1" thick N/A N/A Structodek® high Density Fiber Board, EnergyGuar(r Perlite Recover Board Minimum %" thick N/A EnergyGuard7 Perlite Roof Insulation Minimum 3/" thick N/A N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20401bs./100 ftp. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. GAF requires either a ply of GAFGLAS® Stratavene Eliminator.. Perforated Venting Base Sheet laid dry or a layer of EnergyGuardTm Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. • Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, GAFQLAS® #80 •"' Ultima Base Sheet, GAFGLAS® Ply 4, GAFGLAS F1exPly 6,'�F@LAS°..' • Stratavene Eliminator Perforated Venting Base Sheet (laid dr5j,elk4bdroie Mop Smooth, Ruberoid® 20, Ruberoid® SBS Heat -Weld"' Smooth or 1tdkMerbie SB.S Heat-Weld7" 25 directly over the top layer of insulation. Adhere VAN geay :60606 see approved mopping asphalt applied within the EVT range and at a eite�420-40 • • • • lbs./sq. (See General Limitation #4). Ply Sheet: (Optional) One or more plies GAFGLAS® Ply 4, GAFGLAS® Fle;Ply 6, GAFGLAS® #80 Ultima Base Sheet, Ruberoid® Mop Smooth, Ruboeroicl® 20 • adhered in a full mopping of approved asphalt applied within the EUTrange and �' at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid® 20, Ruberoid' 30, Ruberoid® EnergyCap- 30 FR SBS Membrane, Ruberoid® 30 FR, Ruberoid® Mop Smooth, Ruberoid® Mop 170 FR, Ruberoid® Mop Granule, RoofMatch'm SBS Modified Granular, Ruberoid® Mop Plus, Ruberoid® Mop FR or Ruberoid® Dual FR fully adhered in an approved asphalt at an application rate of 25 lb./sq. f 15%. NOA No.: 13-0424.14 MIAMI•DADE COUNTY • • • Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 8 of 29 goes.. .0060. g • 0.000 006606 ..gess WOOD DECK SYSTEM LIMITATIONS: 1 A slip sheet is required with GAFGLAS® Ply 4 and GAFGLASO FlexPly' 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum '/a" DensDeck® Roof Board or %z" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105#VA calculations in compliance with Roofing Application Standard RAS 117. ' ... • • 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requiremjryt5 df these • • • . areas. Fastener densities shall be increased for both insulation and base sheet as caku>at®d in • • •' compliance with Roofing Application Standard RAS 117. Calculations prepared, sigiaeamid sealed' by a Florida registered Professional Engineer, Registered Architect, or Registered Rv9PE9nsu1t6t* • • • (When this limitation is specifically referred within this NOA, General LimitatiWM will ;qt.. be applicable.) ' 0:0*: 0000 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing terminatio � si shall conform to Roofing Application Standard RAS 111 and applicable wind load r;qufreihents.: 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure bones (i.L. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be p6nitted for : • • enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). 0000 (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 29 of 29 0000.• ..0900 ...909 ,00000 • 99999 009999 0 0 99999• 0000.. 0 • Home Quick Guide Contact Us UL.com TGFU.1R14153 Roofing Systems Roofing Systems See General Information for Roofing Systems GAF 1361 Alps Rd Wayne, NJ 07470-3700 USA Page Bottom R14153 "Ruberoid@ 20" or "Ruberoid@ 20 HT" or "Ruberoid@ Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets in any of the following Classifications. 1/2 -in. thick (minimum) gypsum board or 1/4 -in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardTm Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck® Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardTPB Roofboard" are to offset a minimum of 6 -in. with the butt joints in the roof deck. If polystyrene is part of the roof system, it must be placed below the overlayment board. Multiple plies of "GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "Tri -Ply@ Ply 6" may be adhered to Georgia- Pacific Gypsum LLC "DensDeck @ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'"' Roofboard" in hot roofing asphalt. "EnergyGuardTm Ultra" is an acceptable alternate to "EnergyGuard"" RF" in any applicable Classification. "GAF Stratavent@ Eliminator'"' Venting Base Sheet (Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. 0000 "GAFGLAS@ Perlite Insulation" may be utilized as a cover board over "EnergyGuardym RF" insulation in•VAo of the following systems. • •• • •• Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopplhg asa�t•�• or UL Classified urethane insulation adhesive. Polystyrene referenced in any of the followins-ga9sificaticns include "EnergyGuard"" EPS Insulation". 0 6 s: • • ' Unless otherwise indicated, all insulations may be adhered with any UL Classified Insulation 40aessive p% 11g;0 the manufacturer's installation instructions (excluding LRF Adhesive O) in any applicable N p;;;Q hbustible Roof Deck Classifications. 0011* 011• References to glass fiber insulation include "EnergyGuard Fiberglass Insulation". ":��� '••••� "EnergyGuardTm Tapered" is an acceptable alternate to "EnergyGuardTm" in any applicable 08ssil*cation. • •••••• e • • ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT 6 : • ' • • •••• • 96 • Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or 'Tri -Ply@ #75 Base Sheet", or • • • • "GAFGLAS@ #80 ULTIMA") is a suitable alternate for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4", or "GAFGLAS@ Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent@ Eliminator'"' Venting Base Sheet (Perforated)" or "GAF Stratavent@ Eliminator' Venting Base Sheet (Nailable)." Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 ULTIMA" or "GAF Stratavent@ Eliminator'"' Venting Base Sheet (Nailable)" may be substituted for Type G1 asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply@ Ply 4" or "GAFGLAS@ Ply 6") as the nailed base ply in the following systems. • • • ,,goes gg•oo• loss. • • $9600 googol • 6 1100••• 9666•• 6 e Bottom ply or base sheet may be solid mopped, spot mopped or mechanically fastened. Unless otherwise indicated, all insulations may be hot mopped or mechanically fastened. "GAFGLAS@ Flashing" or "Ruberoid@" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE@" or any other UL Classified perlite insulation. Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. Structural cement fiber building units are considered suitable to be included as a deck in the following Class A, B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1h -in. minimum thick gypsum board is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3k -in. thick perlite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuardTm RA" or "Tapered EnergyGuardTm RA" or "EnergyGuardTm Composite RA" may be substituted for any Atlas Roofing Corp. polyisocyanurate insulation in any of the following Classifications. Trumbull "Perma Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS@ #80 Premium Base Sheet" may be used in any of the following systems. "GAFGLAS@ Flex Ply 6" and 'Tri -Ply® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLAS@ Ply 6". "GAFTEMP Permalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC Classifications. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "TOPCOAT@ Fireshield MB" at 21/2 to 3-gal/100-W. "Ruberoid@ Dual Smooth" may be used as an alternate to "Ruberoid@ Mop Smooth" or "Ruberoid@ 20" or "Ruberoid@ 20 HT". "Ruberoid@ Mop Smooth 1.5" may be used as an alternate to "Ruberoid@ Mop Smooth". Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid@ Heat Weld" SBS roofing membrane may be used in lieu of "Ruberoid@ Mop" SBS products in any applicable Classification. Deck: C-15/32 incline: 1/2 Insulation (Optional): — Perlite, fiber glass, polyisocyanurate, urethane or perlite/polyisocyanurate composite. Base Sheet: — One or more layers Type G2 "GAFGLAS@ #75 Base Sheet" or 'Tri -Ply@ #75 Base Sheet" or Type G3 "GAFGLAS@ Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced.•• Cap Sheet" hot mopped or mechanically fastened. "�.•• Ply Sheet (Optional): — One or more plies Type G1, hot mopped in place. ; •' • .. 0 Membrane: — "Ruberoid@ Mop 170 FR" or "Ruberoid@ Dual FR" or "Ruberoid@ 1018p FR" or "Ruberoid@ EnergyCapTM Mop FR. •••••• • • • •