Loading...
RF-14-1961Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-221414 Scheduled Inspection Date: October 22, 2014 Inspector: Rodriguez, Jorge Owner: MUELLER, ADAM & ALAYNA Job Address: 9190 NW 1 Avenue Miami Shores, FL Project: <NONE> Contractor: CURTIS SMITH CONSTRUCTION LLC Building Department Comments Permit Number: RF -9-14-1961 Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number (786)402-0330 Parcel Number 1131010160030 Phone: (561)768-2409 REPLACE APPROXIMATELY 30BROKEN CLAY TILES Infractio Passed Comments GLUE APPROXIMATELY 30 CLAY TILE BACK TOGETHER INSPECTOR COMMENTS False AND INSTALL 2 MISSING RAKE CAPS TERRACOTTA CLAY S Passed U;t Failed Correction ❑ Needed Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. Inspector Comments CREATED AS REINSPECTION FOR INSP-219229. Provide uplift test &)Aeia-A--7- el505-� October 21, 2014 For Inspections please call: (305)762-4949 Page 14 of 29 Tel: 78&398-9179 Fax: 786-800-2627 airoofinmee ionOgmall.com LAB CERTIFICATION #10-0512-04 SITE SPECIFIC INFORMATION UPLIFT TEST — TAS #106 Roofing Contractor CURTIS SMITH CONSTRUCTION Permit # FR9-141961 Job Address 9190 NW 7 AVE MIAMI SHORES, •FL. 33t6O Owner's Name ADAM & ALAYNA MUELLER Type of Tile ALTUSA Date Installed Approximate Roof Height 12' feet Roof Pitch 3112 Type of Access to Roof LADDER Approximate Square Footage of Roof 1 ft? Required Testing Force 35 Lbs Date Tested 10!16114 Number of Tests 1 Testing Equipment F.G.E.100 Contact Name KEvEN Smom Phone# 561--768-2409 LOCATION # OF TEST PASS # OF TEST FAIL Comer 0 Vests 0 Pass Test Fail Perimeter 0 Tests 0 Pass Test Fail Field 1 Tests 1 Pass Test Fail Ridge o Tests 0 Pass Test Fail TOTAL 1 Tests 1 Pass Test Fail IN ACCORDANCEWrIllTHE.CdtIMIAW..PROTOCOLPA].OS,?MS-ROOFASSEMBLYHAS.PASSEDTHE STAMCUPUFrM UITY.COMTRC1 TW.TMSTA&MTMHMSEMPWUWMRWN.RALACCORDANCE.TMTHE.. REWRBRUM OF DADECOUNTAY, WITH NO DEVIATIONS. THIS REPORT IS NOTGUARANTEW IN CASEOF CASE OF NATURAL DISASTERS. THIS REPORTRIS NOTVALID FOR INSURANCE CLAMS. t. YB ANT:' LEYVA w 3 � A-1 Engineerin§ Inspection Services, Inc 7066 SW 44 Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 alroofms ecp tionggmail.com LAB CERTIFICATION # 10-0512.01 10/16/14 PERMIT. # FR9-14-1961 9190 NW 1 AVE NIIANII SHORES, FL. 33150 7066 SW 44' Street Miami, FL 33155 Tel: 786-398-9179 Fax: 786-800-2627 BUILDING PERMIT APPLICATION Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION UNE PHONE NUMBER: (30S) 762-4949 ❑BUILDING ❑ ELECTRIC ROOFING SEP 0 9 2014 FBC %20 io Master Permit No. 4F A / J / 9 Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL ❑PLUMBING [:]MECHANICAL ❑PUBLIC WORKS [:]CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: q / g® "w Mr Q Vie City: Miami Shores County: Miami Dade Zip: 33/ S-0 Folio/Parcel#: I - 710 / - ®/,6 ^ 0030 Is the Building Historically Designated: Yes NO Vo"' Occupancy Type: S. F. Load: Construction Type: elz s Flood Zone: t%xO BFE: FFE: OWNER: Name (Fee Simple Titleholder): ADAM Phone#: Address: q g® "(A.) I S7' AVe City: &%i A r--% I S"'Oa E S State: Fe-- Zip: Tenant/Lessee Name: Phone#:_ Email: s4j itn ur L -L -<j 1:2, e Ar Ll CSA.! . u!r 33/ SJ CONTRACTOR: Company Name: CAJRx1.S sine °'�1 ca N,STizv4r'yj "e- Phone#: C"61 -76&—Z'1 Address: /0/4e I J City: UE! State: Zip: Qualifier Name: iZa S Si^'� B'P7�i Phone#: S6/—WT--Z /C9 State Certification or Registration #: �� �Z"`'/ `/ Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address: City: State: Zip: Value of Work for this Permit: $ Square/Unear Footage of Work: ��e-� Sq l Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Description of Work: �E a'�p ce A�pr��,u ,�-, �►�Ecsy °3-0 c., -A G`.y6 AppP*k) "reW 3"b c-* fi/e cAcx 1b6ETAjdR ANO (:'�.5 Specify color o/fry color thru tile: TcR-KA L oTA c°c-A y S Submittal Fee $ J " -00 Permit Fee $ - CCF $ C) GO CO/CC $ el? co Scanning Fee $ -- _� Radon Fee $ �DBPR $ Notary $ o Technology Fee $ CD' Training/Education Fee $ ° �� Double Fee $ Structural Reviews $ Bond $ TOTAL FEE NOW DUE $ b7 ' (Revised02/24/2014) ® - _. - - Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspectio whi h occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be ppro ed and a reinspection fee will be charged. or AGENT The foregoing instrument was acknowledged before me this 61 day of SES 20 l `� by mocks.- . who is personally known to me or who has produced identification and who did take an oath. NOTARY PUBLIC: Print: TI .•.....;' I '! K•1 4gog * MYRTIL Seal: *�, Notary Public - State of Florida " : •_ My Comm. Expires Dec 15, 2016 Commission # EE 833810 Bonded Through National Notary Assn. �ItN��lt##�Y•44#N�89eSIIe�RKeye�kRN��kd��MBeMM�Ie#BMS +I�II99e�R�h�InB�kffi�RSea APPROVED BY (Revised02/24/2014) Signature ONTRACTOR The foregoing instrument was acknowledged before me this day of . 20 / 9 . by who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Print• a'2 » Notary Public - State of Florida Seal: w : • My Comm. Expires Dec 15, 2016 Commission # EE 833810 Bonded Through National Notary Assn. as �R�It B�FSK#�R kiB�R+R# �k�R N�$ �R�M yt6�M8i! t8 �� t�Itye4igE4��ReR�RAt�k97B99+k�R8�R6�►## Plans Examiner Zoning Structural Review Clerk Nt (Revised02/24/2014) Signature ONTRACTOR The foregoing instrument was acknowledged before me this day of . 20 / 9 . by who is personally known to as me or who has produced identification and who did take an oath. NOTARY PUBLIC: Print• a'2 » Notary Public - State of Florida Seal: w : • My Comm. Expires Dec 15, 2016 Commission # EE 833810 Bonded Through National Notary Assn. as �R�It B�FSK#�R kiB�R+R# �k�R N�$ �R�M yt6�M8i! t8 �� t�Itye4igE4��ReR�RAt�k97B99+k�R8�R6�►## Plans Examiner Zoning Structural Review Clerk 9/6/2014 CURT°IS SMITH CONSTRUCTION STATE LICENSED AND INSURED AJ Mueller Curtis Smith Construction, LLC 9190 NW 1" Ave Kevin L Smith Miami Shores, FL 33150 10141 Sandy Run Rd Jupiter, FL 33478 www.curtissmithconstruction.com smith construct@hotmail.com 561-768-2409 RE: Roof Repair Quotes For 9190 NW 1t Ave To: Mr. Mueller: Curtis Smith Construction, LLC as a state certified roofing contractor license #CCC 1328544 is pleased to submit our proposal for the repair of the existing broken, missing and cracked clay tiles on your roof located at 9190 NW 1 st Ave in Miami Shores, FL. The bid details are included within Exhibit "A", `B" and "C" of this bid. Please see appropriate Exhibit for corresponding bid details. Exhibit "A" — The Repair of the Existing Broken, Missing and Cracked Clay Tiles on your Roof Exhibit "B" — Contractual Provisions Exhibit "C" — Signature Page The job costs to complete the roofing project with all options quoted is as follows: 1) The Repair of the Existing Broken, Missing and Cracked Clay Tiles on your Roof Page 2 "This quote does not and should not require a permit. Your property is in Miami Shores and know they will want a permit to complete this work. -1- 9/6/2014 L-I CURTIS SMITH CONSTRUCTION EXIIIBIT "C" SIGNATURE PAGE THIS BID IS VOID AFTER 90 -DAYS! I have read all Seven (7) pages of this contract and accept all terms contained herein and understand that this is a legal and binding contract for the amount due listed above. This contract is subject to the additional review and acceptance of Curtis Smith Construction, LLC. Curtis Smith Construction, LLC could decline this contract without notice. Curtis Smith Construction, LLC will not honor any verbal agreements, no exceptions. Final payment is due in full on completion of the project not on completion of the final inspection. Audkol Si ontra ate -7- waterp►ooentS!yWenis J �. C294-260143 Authorized PREFERRED^" `��' —` U100FPL# R�oaem�ai xoofing ler TM {$NTRACTOR i ✓co mns Wmt> M THERMO -FLEX- ACRYLIC COATING SYSTEMS ISL :�16'� � ^ CH��'�E -7- Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: /I 10050 NE 2nd Ave Miami Shores, A 33138 Re: Owner's Name: A DA rv-N rv-1 045 Property Address: 0 IJL%J 4S7" -4045� Roofing Permit Number: Dear Building Official: I A DA &--) M V E 7Z certify that I am not required to retrofit the roof to wall connections of my building because: e just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach prof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) AJ Sigl ature(j Print Name State of Florida County of Dade The undersigned, being the first duly swom, deposes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this Notary Public, Sate of Florida at Large 0 W.MY MYRTIL Notary Public - State of Florida My Comm. Expires Dec 15, 2016 Commission # EE 833810 Bended engrNational Notary Assn. • When the just valuation of the structure for purpose of ad valorem tam is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 SFBC. Then you must provide a building application from a General Contractor for the Roof to Wall connection Hurricane Mitigation. Revised on 5121/200.9 Property Search Application - Miami -Dade County Page 1 of 1 OFFICE OF THE F"ROPERTY APPRAISER ° q ls° fV Summary Report Property Informatio Folio: 11-3101-016-0030 Property Address: 9190 NW 1 AVE Owner ADAM MUELLER ALAYNA MUELLER Mailing Address 9190 NW 1 AVE MIAMI SHORES, FL 33150 Primary Zone 0800 SGL FAMILY - 1701-1900 SQ Primary Land Use 0101 RESIDENTIAL -SINGLE FAMILY: 1 UNIT Beds / Baths / Half 3/2/0 Floors 1 Living Units 1 Actual Area Sq.Ft Living Area Sq. Ft Adjusted Area 1,585 Sq.Ft Lot Size 10,800 Sq. Ft Year Built 1950 Assessment Information Year 2014 2013 2012 Land Value $97,632 $77,760 Building Value $128,956 $130,747 $120,064 XF Value $3,074 $122 Market Value $278,030 $231,453 $197,946 Assessed Value $278,030 $231,453 1 $197,946 Benefits Information Benefit Type 2014 2013 2012 Homestead Exemption $25,000 Taxable Value $228,030 $231,453 Second Homestead Exemption $25,000 $25,000 $0 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES MANOR PB 45-13 LOT 3 LOT SIZE IRREGULAR OR 19073-3240 02 2000 1 COC 26430-4228 06 2008 1 Generated On : 9/61 Taxable Value Information Previous 2014 2013 2 County v Exemption Value $50,000 $0 Qualification Description Taxable Value $228,030 $231,453 $197, School Board Exemption Value $25,000 $0 Financial inst or "in Lieu of Taxable Value $253,030 $231,453 $197. City Exemption Value $50,000 $0 Taxable Value $228,030 $231,453 $197. Regional Exemption Value $50,000 $0 Taxable Value $228,030 $231,453 $197, Sales Information Previous OR Book - OR Price Qualification Description Sale 9 Financial inst or "in Lieu of 07/16/2012 $100 28252-0576 Forclosure" stated Corrective, tax or QCD; min 07102/2012 $100 28252-0574 consideration 06/06/2012 $356,000 28149-2029 Qual by exam of deed Financial inst or "In Lieu of 12/09/2010 $177,500 27530-2960 Fordosure" stated The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appra and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http:/hwww.miamidade.gov/nfb/disclaimer.asp http://www.miamidade.gov/propertysearch/ 9/6/2014 ROOF ASS B D OFT UCTURES CCPlorida Building Code Edition ��� H Velocity Hurricane Zone Uniform Permit Application Form. Master Permit No. Process No. Contractor's Name CuR-7-15 S/ n a-F%J Job Address ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Asphaltic ❑ Metal Panel/Shingles Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof ❑ Reroofing ❑ Recovering ROOF SYSTEM INFORMATION B Mortar/Adhesive Set Tile ❑ Wood Shingles/Shakes Repair ❑ Maintenance Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) ® ®'� ZZ5-0 GZ SrO Section R (Reef Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drab Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location parapets. FLORIDA 9190 NW ist Ave Top vies, Install 2 Missing Rata Fastened With a 3M Bond Adhesive and Ft With I 3;12 La Pena Distant Clap Tile Roof, Replace Tiles Will Be Santa Fe or A WhIch Ever Tile FBs E Replace Approx. m Broken Ck]p Tiles Thrmghwt the Roof And Fasten With a 3M or Tile Bond Adhesive Gkm Back Together 30 Cradaed Roof T RT -600 T ROOF ASSEMBLIES AND ROOFTOP STRUCTURES njo Florida Building Code Edition� .L-) High -Velocity Hurricane Zone Uniform Permit Application Form. Roof System Manufacturer: sIQI•.r�AFE OM --,ur_ACA5r4– (-&–T w5Q) Notice of Acceptance Number: 12"OZIO .af 0 F az —17 3 . 0`7 Minimum Design find Pressures, If Applicable (From RAS 127 or Calculations 'I • P2• - Gg . l P3• Maximum Design Pressure (From Product Approval Specific System): Deck Type: (AJO01--> uNkNOwrJ -ryl`>E Type Underlayment: Utj g1' DuJIJ Roof Slope: s 12 Insulation: rv�p Fire Barrier: N�p Ridge Ventilation? Fastener Type & Spacing: UNI�^1�uJnJ Adhesive Type: N��1 Type Cap Sheet: I ctox,1,3 N07- t"!!p g5o Mean Roof Height: ' ®� Roof Covering: I C.t.A)/ TERRA GaiA S Type & Size Drip UNKI'-'DL.JtJ Edge: FLORIDA BUILDING CODE — BUILDING I ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Editions go to High Velocity Hurricane Zone Uniform Permit Application Form. SpCtien E (Mle CalCulationc) ForMoment based the systems, choose eitherMethal I or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the tile attachment method is acceptable. Methal I "Moment Based Tile Calculations Per RAS 127" (Pi: x 2 = ) - Mg: = Mri Product Approval Mf (Pz: x 7l = ) - Mg: = Mrz Product Approval Mf (P3: X % —=—)-Mg:—=K3— Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf M re uired Moment Resistance* Mean Roof Height -I Roof Slope i5' 20' 25' 30' 40' 2-12 222 34A 36-0 4,12 199 It 7:12 244 25S 27-1 2fi-2 38-0 *Must be used in conjunction with a list of moment based file systems endorsed by the Broward County Board of Rules and Appeals. ForUpiift based tile systems use Method 3. Compared the values forF with the values forR Uthe F values are greater than orequal to the Fr values, for each area of the roof, then the the attachment method is acceptable. Method 3 "Moment Based Tile Calculations Per RAS 127" (Pt: x L = x W: = ) - W. x cos B = Fri Product Approval F (Pz: x L = x W: = _� - W. x cos 8 = Fa Prodact Approval F' lP, x 1. — x w' = 1 - w- x me 9 = F_.. Prodne Amtrnval F' Where to Obtain Information Description SyMbol Where to find DesianPressure Pl w P2 or P3 RAS 127 Table 1 or by an anpineering wWy& prepared by PE based on ASCE 7 Mean Roof Height H Job Site RoofS1oDe 0 Job Site Aerodynamic Multi tier 2 Product Awroval Restoring Moment due to Crre " MB Product Approval Attachment Resistance M Product al Rewired Moment Resistance M Calculated Minimum Attachment Resistance F' Product Approval Reunited U lift Resistance Fr Calculated AM= Tile Wei W Product Amroyal Tile 1?imensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of pernut Gcation. FLORIDA BUILDING CODE — BUILDING Santafe Tile Corporation 8825 NW 95`" Street Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This replaces NOA# 10-1005.15 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. hnArlaw�e Couwrir NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 1 of 5 MIAMf MIAMI DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/pera Santafe Tile Corporation 8825 NW 95`" Street Medley, FL 33178 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Santafe Spanish `S' Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This replaces NOA# 10-1005.15 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. hnArlaw�e Couwrir NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 1 of 5 ROOFING ASSEMBLY APPROVAL Category Sub -Category Material: Deck Type: Roofing Roofing Tiles Clay Wood 1. SCOPE This approves a roofing system using Santa Fe "Santafe `S" Clay Roof Tile, as manufactured by Ladrillera Santafe S.A. in Bogota, Colombia and distributed by Santafe Tile Corporation as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Identifier Test Product ADulicant Dimensions Specifications Descriation Santaf6 `S' Clay Roof L =18" TAS 112 One piece high profile clay roof file equipped with Tile W =11.1" TAS 101 two nail holes. For nail -on, mortar set and adhesive The Center for Applied Engineering, Inc. Project: 07-07-00-91 TAS 100 set applications. Trim Pieces 1= varies TAS 112 Accessory trim, clay roof pieces for use at hips, Redland Technologies w = varies TAS 108 rakes, ridges and valley terminations. Manufactured varying thickness (Nail -On) for each tile profile. 2.1 MANUFACTURING LOCATION 1. Bogota, Colombia 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Renort Date The Center for Applied Engineering, Inc. 94-156-8 TAS 101 Aug. 1994 94-156-9 TAS 102 The Center for Applied Engineering, Inc. 25-7205-1 TAS 101 March 1995 The Center for Applied Engineering, Inc. Project: 07-07-00-91 TAS 100 Sept. 1994 (307023) Redland Technologies 7161-03 TAS 108 Dec. 1991 Appendix H (Nail -On) Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102 & TAS 102(A) Redland Technologies P 0402 Withdrawal Resistance Sept. 1993 Testing of Screw vs smooth shank nails NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 2 of 5 N 2.2 SUBMITTED EVIDENCE Test Agency Test Identifier Test Name/Rep ort Date Redland Technologies P 0647-01 TAS 108 Aug. 1994 0.958 (Mortar Set) Redland Technologies P 0631-01 PA 108 July. 1994 (Mortar Set) Celotex Corporation Testing Services 520305-01 thru 05 PA 102 June 1999 IBA Consultants, Inc. 2353-4 Restoring Moment Aug. 1999 PRI Asphalt Technologies, Inc. SFTC-003-02-01 TAS 101 12/06/02 IBA Consultants, Inc. 2353-70 TAS 101 09/22/03 IBA Consultants, Inc. 2353-71 TAS 101 09/22/03 IBA Consultants, Inc. 2353-93 ASTM C 1167 07/18/05 3. LpmTATIONs 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Santafe 'S' and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w) Tile Profile Weight W (Ibt) Length -I (ft) Width -w (ft) Santafe 'S' 6.7 1.5 0.958 NOA No.: 12-0210.01 hnAa�Fawe G( Expiration Date: 02/01/16 JAPPROVEDI Approval Date: 05/31/12 Page 3 of 5 Table 2: Aerodynamic Multiplyers- k(fe) Tile Profile 7. (fe) Batten Application ;L (ft) Direct Deck Santafe 'S' 0.274 0.297 Table 3: Restoring Moments due to Gravity - M® (ft-lbf) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or grester 21.8 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Santafe 'S' 5.93 5.90 5.85 1 5.82 5.73 5.69 5.56 5.53 5.32 5.29 5.03 5.00 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for NaiWn Systems Tile Profile Tile Profile f=astener Type Direct Deck Battens Santafe 'S' 2-10d Ring Shank Nails 21.8 N/A One #8 Screw 29.16' - N/A Two #8 Screws 38.28 N/A One #8 Screw w/ Clip 57.31 N/A Two #8 Screws w/ Clip 57.60 61.77 1. Approved screws as noted 'Product manufactured by others'. l 2. When using one screw it must be installed in the inside hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment s ce Santafe 'S' Vie Bon38.9- Polyfoarn Polypro AH 160Tm 28. 2 See manufactures component approval for installation requirements. 3 Flexible Product, Inc. Average weight per patty 10.4 grams. 4 Polyfoam Product, Inc. Average weight per patty 9.4 grams. Table 5A: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Tile Application Minimum Attachment Resistance Santafe'S' Application Polyfoam Polypro,AH 160Tm 8 0 oam o ro 61.9 5 Paddyplacement of 63 rams of Poly pro AH 160Tm. 6 Paddy placement of 24 grams of Polypro AH 160Tm. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Attachment Profile Application Resistance Santafe 'S' Mortar Set 23.6 NOA No.: 12-0210.01 t DAOE country Expiration Date: 02/01/16 JAPPROVEDI Approval Date: 05/31/12 Page 4 of 5 S. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as shown below, or following statement: "Miami -Dade County Product Control Approved". SANTA FE TM MADE IN COLOMBIA LABEL FOR SANTA FE SPANISH "S" CLAY ROOF TILE 6. BUILDING PERART REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system PROFILE DRAWING When using one screw ;e this hole. "SANTAFk S" CLAY ROOF TILE END OF THIS ACCEPTANCE NOA No.: 12-0210.01 Expiration Date: 02/01/16 Approval Date: 05/31/12 Page 5 of 5 MIAMI -DARE COUNTY MIAM!•DADE PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/eeonomv Sulacer USA, Inc. 6801 NW 77 AVE, Suite #302 Miami, FL 33166 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Altusa "S" Clay Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 11-0707.03 consists of pages 1 through 9. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 1 of 9 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Clay Deck Type: Wood 1. SCOPE This approves a roofing system using Altusa "S" Clay Roof Tile as manufactured by Sulacer, S.A. de C.V. in Pimienta Cortes, Honduras and distributed by Sulacer USA, Inc., as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Applicant Altusa "S" Clay Roof Tile Length: 18-3/4" Width: 10-3/4" Thickness: 0.46" Height: 3.6" Trim Pieces Length: varies Width: varies varying thickness Test Product Specifications Description ASTM C 1167 High profile, one-piece, `S' shaped single roll clay tile with a nominal 2-'/2 inch headlap. For direct deck nail -on, mortar set, or adhesive set applications. TAS 112 Accessory trim, clay roof pieces for use at hips, rakes, ridges and valley terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 2.1.1. Pimienta Cortes, Honduras 2.2. EVIDENCE SUBMITTED Test Aeencv Test Identifier American Test Lab of South RT0426.01-11 Florida American Test Lab of South Florida American Test Lab of South Florida American Test Lab of South Florida The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. RT0706.01-11 2397-116 RT0712.02-13 Test Name/Revort ASTM C 1167 Static Uplift Testing TAS 101 ASTM C 1167 ASTM C 1167 94-083 Static Uplift Testing TAS 101 (Adhesive Set) 94-084 Static Uplift Testing TAS 101 (Mortar Set) Date 05/07/11 07/11/11 06/28/07 07/19/13 April 1994 May 1994 NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 2 of 9 The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Celotex Corporation Testing PRI Asphalt Technology, Inc. Redland Technologies Redland Technologies Redland Technologies Redland Technologies Redland Technologies Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. 25-7200-1 Project No. 307025 Test #MDC -78 MTS 520649 CLF -003-02-01 7161-03; Appendix III 7161-03 Appendix H Letter Dated Aug. 1, 1994 P0631-01 P0402 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Static Uplift Testing TAS 102 (Quick -Drive Screws, Battens) Wind Driven Rain TAS 100 TAS 102(A) TAS 102 TAS 102 Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Nail -On) Wind Tunnel Testing TAS 108 (Mortar Set) Withdrawal Resistance Testing of screw vs. smooth shank nails Aerodynamic Multiplier 25-7183 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Feb. 1995 Oct. 1994 May 2000 October 2001 Dec. 1991 Dec. 1991 Aug. 1994 July 1994 Sept. 1993 March 1999 March 1995 February 1996 April 1996 December 1996 NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 3 of 9 3. Lu%nTATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 33 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. 3.8 May be installed on slopes 7:12 and greater. 4. INSTALLATION 4.1 Altusa `S' Clay Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight -W (Ibf) Length4 (ft) Width -w (ft) Altusa "S" Clay Roof Tile 6.5 1.56 0.9 Table 2: rodynamic Multipliers - ft$ Tile Profile A. (ft) Batten Application (ft3) Direct Deck Application Altusa "S" Clay Roof Tile 0.253 0.28 Table 3: Restoring Moments due to Gravi - M ft -Ib Tile Profile 3": 12" or less 4": 12" 5": 12" 6": 12" 7": 12" or grester Altusa "S" Clay Roof Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 1 4.47 5.35 1 4.40 5.27 4.31 5.16 4.20 5.03 4.08 4.89 NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 4 of 9 Table 4: Attachment Resistance Expressed as a Moment - M, (ft-lbf) for Nail -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile Altusa "S° Clay Roof (Min 15/32" plywood) (Min. 19/32" plywood) Tile Altusa "S" 2-10d Ring Shank Nails 28.6 41.2 19.4 Clay Roof Tile 1-10d Smooth or Screw 5.1 6.8 2.8 Shank Nail 2-10d Smooth or Screw 6.9 9.2 7.3 Shank Nails 1 18 Screw 28.7 28.7 18.1 2 .#8 Screws 58.2 58.2 26.8 1-10d Smooth or Screw 23.1 23.1 19.0 Shank Nail Field Clip) 1-10d Smooth or Screw 29.3 29.3 24.0 Shank Nail Eave Clip) 2-10d Smooth or Screw 27.6 27.6 38.6 Shank Nails Field Clip) 2-10d Smooth or Screw 38.1 38.1 41.8 Shank Nails Eave Clip) 1 Screw with Altusa Clip See cli details Altusa "S" 1 Screw with clip (at the head 187.1 187.1 N/A Clay Roof Tile' of tile) Altusa "S" 1 Screw with clip (at the water 35.2 35.2 N/A Clay Roof Tile' course of tile) 1. Screw must be installed in the inside nail hole located nearest to the hump of the tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Altusa "S° Clay Roof Adhesive 29.3 Tile 2 See manufacturer com nent approval for installation requirements. 3 Repble Products Company TiIaBond Average weight per patty 10.7 grams. 3Wm 2 -Component Foam Roof Tile Adhesive AH -160 Average weight pera 8 grams. NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 5 of 9 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single PaMf Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Altusa "S" Clay Roof 3M 2 -Component Foam Roof 0 66 Tile 3M 2 -Com onent F o e Adhesive AH -160 38.7 3 2 -Com onent Foam Roof Tile Adhesive AH - 4 Large paddy placement of 63grams of 3M 2 -Component Foam Roof Tile Adhesive AH -160 5 Medium paddy placement of 24grams of 3M 2 -Component Foam Roof Tile Adhesive AH -160 6 Large paddy placement of 54grams of 3M 2 -Component Foam Roof Tile Adhesive AH -160 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Altusa °S" Clay Roof Tile Mortar Set 24.50 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County .Product Control Approved". ALTUSA MADE IN HONDURAS LABEL FOR ALTUSA "S" CLAY ROOF TILE. (LOCATED ON TBE UNDERSIDE OF TILE) 6. BUII.DING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 6 of 9 PROFILE DRAWING ALTUSA `S' CLAY ROOF TILE NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 7 of 9 TILE BY AL (TYP.) CUP WITH ONE (1) SCREW ATTACHED TO DECK CLIP DETAILS 2412' OVERLAP (COVERS PIN HOLE) CUP PLACEMENT DETAR SCREW IN THE INSIDE HOLE NEAREST TO THE HUMP OF THE TILE NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 8 of 9 SCREW (HOLDS CLIP ONTO DECK) CLIP DETAILS (CONTINUED) TILE BY ALTUSA (TYP.) E CUP PLACEMENT DETAIL 2 Ur OVERLAP (COVERS PIN HOLE) SCREW IN THE INSIDE NAIL HOLE NEAREST TO THE HUMP OF THE TILE DECK 11/4" 13/4" 3/4° END OF THIS ACCEPTANCE GALVANIZED METAL CLIP 2112' SCREW NOA No.: 12-1203.07 Expiration Date: 08/26/14 Approval Date: 09/19/13 Page 9 of 9 MhNl DlEJ I }` MIAMI -DARE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy 3M Company 3M Center Building 0220-05-E-06 St Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: 3M Foam Roof Tile Adhesive RTA -1 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This revises NOA# 12-0529.01 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 13-0129.01 Expiration Date: 01/03/16 ,-0000w, #Oe� Approval Date: 11/07/13 Page 1 of 7 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3M Foam Roof Tile Adhesive RTA -1 as described below in this Notice of Acceptance, designed to comply with the Florida Building Code. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values; as obtained by calculations in compliance with RAS 127, using 3M Foam Roof Tile Adhesive RTA -1, and where the attachment calculations shall be done as an moment based system. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Product Description Specifications 3M Foam Roof Tile N/A TAS 101 Single component polyurethane foam roof tile Adhesive RTA -1 adhesive. MANUFACTURING LOCATION: 1. Norton, OH. PHYSICAL PROPERTIES: Prope Test Density ASTM D 1622 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2842 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 EVIDENCE SUBMITTED: Test Aeency Southwest Research Institute PRI Construction Materials Technologies, Inc. Results 1.95 lbs./ft 3 7.8 psi 15 PSI Parallel to rise 4.6 Lbs./Fe 1.94 Perm / Inch +0.89% Volume Change @ 70° C., 2 Weeks 54.1% Test Identifier Test Name/Report 01-1208-025 ASTM E 108 FOP -009-02-10 Physical Properties FOP -009-02-01 TAS -101 FOP -009-02-02 TAS -101 FOP -009-02-03 TAS -101 FOP -009-02-04 TAS -101 FOP -009-02-05 TAS -101 Date 06/16/98 12/14/10 11/8/10 11/4/10 11/8/10 11/8/10 11/8/10 NOA No.: 13-0129.01 Expiration Date: 01/03/16 Approval Date: 11/07/13 Page 2 of 7 LIMITATIONS: 1. Fire classification is not part of this acceptance. 2. 3M Foam Roof Tile Adhesive RTA -1 can be used with flat, low, medium and high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of 3M Foam Roof Tile Adhesive RTA -1 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. F'= [f2 W MS INSTALLATION: 1. 3M Foam Roof Tile Adhesive RTA -1 may be used with any roof tile assembly having a current NOA that lists moment resistance values with the use of 3M Foam Roof Tile Adhesive RTA -1. 2. 3M Foam Roof Tile Adhesive RTA -1 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3M Foam Roof Tile Adhesive RTA -1 shall provide sufficient attachment resistance, expressed as a moment based system, to meet or exceed the moment resistance determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA 3. 3M Foam Roof Tile Adhesive RTA -1 roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and Fomo Products, Inc. 3M Foam Roof Tile Adhesive RTA -1 Operating Instruction and Maintenance Booklet 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by Polyfoam Products, Inc. 5. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after 3M Foam Roof Tile Adhesive RTA -1 has been dispensed. 6. 3M Foam Roof Tile Adhesive RTA -1 placement shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Typical Placement Detail Weight per paddy (grams) Flat, Low & fligh Profile # 1 12 High Profile 2 -Piece Barrel # 2 12 LABELING: All 3M Foam Roof Tile Adhesive RTA -1 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 13-0129.01 Expiration Date: 01/03/16 Approval Date: 11/07/13 Page 3 of 7 ADHESIVE PLACEMENT DETAILS PLACEMENT DETAIL ## 1 FLAT PROFILE 3e line PW* nye the NOA No.: 13-0129.01 Expiration Date: 01/03/16 Approval Date: 11/07/13 Page 4 of 7 PLACEMENT DETAIL # 1 (CONT... A Low P1tOFuLE NOA No.: 13-0129.01 hn u 0 Expiration Date: 01/03/16 APPROVApproval Date: 11/07/13 Page 5 of 7 Eas owse Ise --., PLACEMENT DETAIL # 2 �1 Start paddy t,tde- mW, pan portion d lite approdmately T' strove file coarse Ins r_ i =- • • ._ _ t - HIGH PROFILE NOA No.: 13-0129.01 JAPPhaahiannROVED I Expirationlir Date: 01/03/16 . � � Approval Date: 11/07/13 Page 6 of 7 PLACEMENT DETAIL # 2 (CONT... _ _ ! Two - T' oblong .. Dowse hie t � � \h ^+ \ We under' pan�U`in • �+ \\�\ an eek de wider \! cover ties \ Uli \ t \tjt) TVWD(2)-1a'o3lo V � Eby side (save couseor�lr). Mo tar este dom 2 -PIECE BARREL PROFILE END OF THIS ACCEPTANCE NOA No.: 13-0129.01 JAPPR � �D Expiration Date: 01/03/16 Approval Date: 11/07/13 Page 7 of 7 MIAMI -DARE COUNTY PRODUCT CONTROL SECTION BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamldade.aov/buildine/ The Dow Chemical Company 1605 Joseph Drive 200 Larldn Center Midland, MI 48674 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: TILE BOND"a Roof Tile Adhesive LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA# 08-0512.18 consists of pages 1 through 9. The submitted documentation was reviewed by Alex Tieera. MOMI•DADE COUNTY NOA No.: 11-0616.03 Expiration Date: 08/23/16 Approval Date: 08/18/11 Page 1 of 9 ROOFING COMPONENT APPROVAL Category: Roofing Sub Category: Roof Tile Adhesive Material: Polyurethane SCOPE: This approves TILE BOND Roof Tile Adhesive as manufactured by The Dow Chemical Company, as described in this Notice of Acceptance, designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. For the locations where the pressure requirements, as determined by applicable building code, do not exceed the design pressure values; as obtained by calculations in compliance with RAS 127, using TILE BOND Roof Tile Adhesive, and where the attachment calculations shall be done as an moment based system. PRODUCT DESCRIPTION: Manufactured by Applicant Dimensions TILE BOND Roof Tile Factory premixed canisters Adhesive MANUFACTURING LOCATION: 1. Wilmington, IL. Product Description Single component polyurethane foam roof tile adhesive NOA No.: 11-0616.03 Expiration Date: 08/23/16 Approval Date: 08/18/11 Page 2 of 9 EVIDENCE SUBMIT m: Test Agency Test Identifier Test Name/Report Date Center for Applied 25-7512-1 TAS 101 01/25/96 Engineering 25-7512-2 TAS 101 01/25/96 25-7512-3 TAS 101 01/25/96 25-77512-4 TAS 101 01/25/96 25-7781 Physical Properties Testing 11/07/96 257794-2 SSTD 11-93 10/03/96 South Research Institute 01.8366-014 ASTM E108 -95a February 1997 Walker Engineering, N/A Evaluation of Test on a Two -pad 12/16/97 Inc. System Celotex Corp. Testing 520111-1 TAS 101 12/28/98 Services 520111-2 TAS 101 12/28/98 520111-3 TAS 101 12/28/98 520111-4 TAS 101 12/28/98 520111-7 TAS 101 12/28/98 520111-8 TAS 101 12/28/98 520111-12 TAS 101 12/28/98 520135-3 TAS 101 02/01/99 520135-4 TAS 101 02/01/99 520135-5 TAS 101 02/01/99 IBA Consultants Inc. 4848-8 TAS 101 05/19/08 4848-7 TAS 101 05/19/08 4848-6 TAS 101 05/19/08 4848-5 TAS 101 05/19/08 4848-4 TAS 101 05/19/08 4848-3 TAS 101 05/19/08 4848-2 TAS 101 05/19/08 4848-1 TAS 101 05/19/08 Trinity ERD D9840.09.09 TAS 110 09/17/09 NOA No.: 11-0616.03 Expiration Date: 08/23/16 Approval Date: 08/18/11 Page 3 of 9 TYPICAL PHYSICAL PROPERTIES: Prove Test Results Density ASTM D 1622 1.83 lbs./ft 3 Compressive Strength ASTM D 1621 14.31 psi Tensile Strength ASTM D 1623 31.21bf @ 180T, 65% RH for 120 days, concrete to concrete Water Absorption ASTM D 2842 2.21 % absorbed by Volume Moisture Vapor Transmission ASTM E 96 3.00 Perm / Inch Dimensional Stability ASTM D 2126 -0.47% Volume Change @-40°C., 2 weeks -4.05% Volume Change @70°C., 100% Humidity, 2 weeks Closed Cell Content ASTM D 2856 86.3% Lpvlm IoNs: 1. Fire classification is not part of this acceptance. 2. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami-Dade County Product Control Approved" or the Miami-Dade County Product Control Seal as shown below. MIAM!•OADE COUNTY 3. TILE BOND Roof Tile Adhesive shall solely be used with flat, low, medium, and high tile profiles. 4. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 5. Roof Tile manufactures acquiring acceptance for the use of TILE BOND Roof Tile Adhesive roof tile adhesive with their tile assemblies shall test in accordance with TAS 101 with section 10.4 as modified herein. C2) W6. F'= W NOA No.: 11-0616.03 Expiration Date: 08!23/16 Approval Date: 08/18/11 Page 4 of 9 INSTALLATION: 1. TILE BOND Roof Tile Adhesive may used with any roof tile assembly having a current NOA that lists uplift resistance values with the use of TILE BOND Roof Tile Adhesive. 2. TILE BOND Roof Tile Adhesive shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of TILE BOND Roof Tile Adhesive shall provide sufficient attachment resistance, expressed as an uplift based system, to meet or exceed the uplift resistance determined in compliance with Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof tile assembly NOA 3. TILE BOND Roof Tile Adhesive roof tile adhesive and its components shall be installed in accordance with Roofing Application Standard RAS 120, and The Dow Chemical Company TILE BOND Roof Tile Adhesive Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained'Qualified Applicator' approved and licensed by The Dow Chemical Company. 5. Pressure treated wood filler block shall be required on all eave course of all tile profiles, except on two piece barrel tile 6. Tiles must be adhered in freshly applied adhesive. Tile must be set within 4 minutes after TILE BOND"" Roof Tile Adhesive has been dispensed. 7. TILE BONWm Roof Tile Adhesive placement and *minimum patty weight shall be in accordance with the Placement Details' herein. Each generic tile profile requires the specific placement noted herein. TABLE 1: ADHESIVE PLACEMENT FOR EACH GENERIC TILE PROFILE Tile Profile Placement Detail Minimum patty Weight per tile (grams) Contact Area (Square inches) Flat / Low Profile #1 11.1 19.5 Medium Profile #2 11.0 19.5 High Profile ( Head) High Profile (Nose) #3 22.0 11.0 39 19.5 Two Piece Barrel #4 11.6 20 LABELING: All TILE BOND'm Roof Tile Adhesive containers shall comply with the Standard Conditions listed herein. BUMDING PERMIT REQUIREMENTS: Any documentation required by the Building Official or applicable building code in order to properly evaluate the installation of this system NOA No.: 11-0616.03 Expiration Date: 08/23/16 Approval Date: 08/18/11 Page 5 of 9 ADHESIVE PLACEmNT DETAIL LOW (FLAT) PROFILE DETAIL #1 NOA No.: 11-0616.03 MIAMI•�ADE CouNTY Expiration Date: 08/23/16 ... , Approval Date: 08/18/11 Page 6 of 9 MEDIUM PROFILE DETAII. #2 NOA No.: 11-0616.03 Expiration Date: 08/23116 Approval Date: 08/18/11 Page 7 of 9 HIGH PROFELE DETAIL #3 APPROVED NOA No.: 114616.03 Expiration Date: 08/23/16 Approval Date: 08/18/11 Page 8 of 9 BARREL PROFILE DETAIL #4 END OF THIS ACCEPTANCE NOA No.: 11-0616.03 Expiration Date: 08/23/16 Approval Date: 08/18/11 Page 9 of 9