Loading...
RF-14-1960%AiamiShores Vlllagol Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ZROOFING FBC 20 10 Master Permit No. g Z 2/j Sub Permit No. ❑ REVISION ❑ EXTENSION ❑ RENEWAL ❑PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP CONTRACTOR DRAWINGS JOB ADDRESS: 60�q N F, q1 S OWNER: Name (Fee Simple Titleholder): �Ycn E acv, Phone#: Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name:R C �7 \ Phone#: 551 Ct�O m Address: � l` o S—V h City (C L1�° g State: VisoatCA- zips: ��.1�� Qualifier Name: � �i fc lC, D Phone#: r ✓ (�&3 • ` (CE2 State Certification or Registration MC `M' 0 50L '400 Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Address City: ___State: �9 Ip: Value of Work for this Permit: Square/Unear Footage of Work: 46 Type of Work: ❑ Addition ❑A Alteration ❑ New ❑ Repair/Replace ❑ Demolition Description of Work: Specify color of color thru the:2 a1, a 9,00 a Submittal Fee $ Permit Fee $ , Scanning Fee $ Radon Fee $ Technology Fee $ Training/Education Fee $ Structural Reviews $ (Revised02/24/2014) CCF $ CO/CC $ DBPR $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ :7 Section A/B 19bo N" Mia -Dade County ECia" is hof Permit Form ® �_;�r laml Sher^s Vill�gel 'l?+E'%%VL'1"%Yig EXCelfeJiC Apr'(lF-0 BY DATE Section A (General Information) Master Permit No: Process No: ®� — ' - - Contractor's Name: FLORIDA ROOF TECH CORP Job Address: 1639 NEW ST Roof Category ❑✓ Low Slope ❑ Mechanically Fastened\Tile✓❑ Mortar/Adhesive Set Tile ❑ Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes ❑ Sprayed Polyurethane Foam ❑—� Other. Roof Type ❑ New Roof 0 Re -Roofing • ❑ Recovering ❑ Repair ❑ Maintenance Are there Gas Vent Stacks located on the roof? ❑ Yes ❑ No if yes, what type? ❑ Natural ❑ LPGX Roof System Information Low slope roof area (f%2) 204 Steep Sloped area (fL2) 1776 Total (ft.2)1980 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, deafly identify dimensions of elevated pressure zones and location of parapets. Perimeter Width (a'): Corner Size (a' x a'): i Iz SEP 0'0 2014 BY A4 A- a� 1-q- Tile Roof System Y M" I ' Miami=Dade County HVHZ Electronic Roof Permit Form Section D Tile Roof System Vdvedmg F-rceffe ce EVVy Dayff Roof system Manufacturer. I BORAL ROOFING LLC Notice of Acceptance Number (NOA): 12-0222.02 Minimum Design Wind Pressures, If Applicable (from RAS 127 or Calculations): P 1: 39.1 P 2: 68.1 P 3: 100.7 Maximum Design Wind Pressures, (From the NOA Specific system): 8.7 psf Fill in the specific roof assembly components. If a component Is not requirsA Insert not applicable (n/a) in the text box. Roof Slope: 0/12" Roof Mean Height 14 ft. Method of Tile Attachment: Adhesive, Medium Paddy Potyfoam Polypro— Alternate Metier of Tile Attachment per NOA:7771 Drip Edge Size & Gauge: —3" face 26 ga.— Drip Edge Material Type:--Gaivinized Metal—� Drip Edge Fastener Type: 11/4 R.S NAILS c@ 4" O.0 Hook Ship/Cleat gauge or weight —Select Hook Strip — Deck Type: 1 --1" x 6" T 9 G— Optional Insulation: Optional Nailable Substrate: Optional Nallable Substrate Attachment: Basesheet Type: 1 PLY # 30 LBS ASTM Fastener Type for Baseshest Attachment 11/4 R.S NAILS 6" ox lap & 12" ox field Tile Underiayment (Cap Sheet ) Type: 1 PLY # 90 LBS ASTM back nailed 12" ox Tile Undertayment Attachment Method: HOT ASPHALT TYPE IV Tile Profile: BARCELONA 900 Section E I MIAMI•M Miami -Dade County HVHZ Electronic Roof Permit Form "Delivering Excellence Every Day" Section E (Tile Calculations) Method 1 "Moment Based Tile Calculations Per RAS 127" For Moment based the systems, use Method 1. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the file attachment method is acceptable. P 1: 39.1 X X .313 = 12.23 - Mg: 8.05 = Mr1: 4.18 5 38.7 NOA Mf P 2: 68.1 XX .313 = 21.31 - Mg: 8.05 = Mr2: 13.26 s 38.7 NOA Mf P 3: 100.7 X .313 = 31.51 - Mg: 8.05 = Mr3: 23.46 S 138.7 1 NOA Mf Method 3 "Uplift Based Tile Calculations Per RAS 127" For Uplift based file systems use Method 3. Compare the values for F' with the values for Fr. If the F' values are greater than or equal to the Fr values, for each area of the roof, then the file attachment method is acceptable. P1: X I: = X w: Design Pressure _ - W: = Mean Roof Height X cos 0: = Fr1: 5 NOA F' P2: X I: Job Site = X w: X _ - W. Restoring Moment due to Gravity = X cos 0: = Fr2: 5 NOA F P3: Required Moment Resistance X I: Calculated = X w: F' _ - W. Required Uplift Resistance = X cos 0: M= Fr3: 5 NOA F Where to Obtain Information to complete the calculations Where to Find Description 1 Symbol Table 1 RAS 127, or by an engineer analysis prepared, signed and sealed by a professional Design Pressure P1 or P2 or P3 engineer based on ASCE 7. Mean Roof Height H Job Site Roof Slope 0 Job Site Aerodynamic Multiplier X Product Approval (NOA) Restoring Moment due to Gravity Mg Product Approval (NOA) Attachment Resistance Mf Product Approval (NOA) Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval (NOA) Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval (NON Tile Dimensions I = length Product Approval (NOA) w = width Code EdIt1cm 2010 fth 1l Hwkarm Zone Urlarrnl Pemvt NEKOM Form , FM . ftaft footASSMoWV , seed SyMm (ff a t� satasad, Wit€ �►� 14mxtroCbjw._ KOA Na: Pr WKL 422 I -71 Ma- Design Raw^ *wn the specific Im Deck Tye : tX PL1 �► •�` a %a Anchw/SM 9Wk&-Mi'4 0104. WA And:/Om Sitoet Fes jBa g ebe�al: kisuhm n 8m.Lmep N/A Base n Faber NIA Top In iliaaed N/A Top 1111513111ftFas�erg ttiUA Bwe s)a ft of Ply(s): T #7S_ rj8or g VA LY RIs Rte WIN cane t Fly Shad er� St�ASTTY[�fll i Top Piy:_ AI.SUWM�CAF! 4 Top Piy► F%BOtk�ig , S SW ASPHaMM!j i Wig: lAI. CqP Sd�i AndmISM s ice: 9_o`bGq tom, * Rias2.__ 0_•_'oc 6 Lap; # �6_."ac Lap. GfFpA. mewpar Boaxd Imo: WA Peftaw. WA Comer: N/A _fie Coqmraeoft Voted and pdaftas WOW -11 lilg6*6e.T 9, Fmc 'Winut. inkCBsa ,..8Fwft t c jHelft at -1,111MOk Hew Fasbm� Type, Spattgor° If t C ly`tart -kW Ul and OMAW IL s�aa°yssa� ' ctaPse�. 1 g3rLya arimapm L• 'moi SECTION 1524 a HIGH VELOCITY HURRICANE ZONES- REQUIRED OWNERS NOTIFICtiiTION FOR ROOFING CONSIDERATION: 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the own( with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Code, Building govern the minimufn requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between,the owner and the contractor. The owner's initial in the designated space indicates that the item has-been explained. 1. Aesthetics -workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are for the purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards: Aesthetics (appearance) are not a consideration with respect to workmanship provision: Aesthetic issues such as color or architectural appearance, that are not part of a zzAin "code; should be addresse, as. part of the agreement between the owner and the contractor. 2. Rensiling wood decks: When replacing roofing,. the existing wood roof deck may have to be renailef in accordance with the current provisions of Chapter 16 (High Velocity: Hurricane Zones) of the Florida Builth g Code. (The roof deck is usually concealed prior to removing the existing rodf:systcra). [�3.mmon goofs: Common roofs are those which have no visible delineation between neighboring units (i.e. townhouses, condominiums, etc.). In buildings with common roofs; the roofing -contractor and/or owner should notify the. occupants of adjacent units of roofing work to bei performed., �- 4. Exposed ceilings: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below.The owner may wish to maintain the architectural appearance; therefore, roofing Trail penetrations of the underside of the decking may not be accppble. The owner provides the option of maintaining this. appearance. 5. Ponding water: The current roof system and/or deck of the building May ,not drain well -and may cause water to pond (accumulate) in low-lying areas of the roof. Ponding can be`A i"catiari of structural distr and may require the review of a professional*structural engineer. Ponding may shortenthe life expec ney and performance of the new roofing system. Ponding conditions may not'be. evident until the origins roofi . system is removed. Ponding conditions should be corrected. . Overflow seuppeA (wall outlets): It is required that rainwater flow off -so that the roof is not overloaded from a. buildup of water. Perimeter/edge walls or other roof extensions may.block this discharge if overflow scuppers;(wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Chapter 15 and 16 herein and the Florida Building Code, Plumbing. 7. Ventilation:. Most roof structures should have some ability to vent natural airflow -through the interior of the structural assembly (the building itself). The existing amount. of -attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida -licensed engineer or registered architect to eliminate the attic venting, venting shall_not be req*ed. Ownees/Agenfs Signature; Contractor's Signature: L Property Address: Date: Permit Number: Boral Roofmg, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -bade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described hereib; and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the jab site at the request of the Building Official. This renews and revises NOA#07-0220.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMFDADE COUMY NOA No.: 12-0222.02 JAPPROVED1 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of 7 MIAMI. \" MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS (PERA) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.zov/sera Boral Roofmg, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County PERA - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. PERA reserves the right to revoke this acceptance, if it is determined by Miami -bade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described hereib; and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Barcelona 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the jab site at the request of the Building Official. This renews and revises NOA#07-0220.04 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. MIAMFDADE COUMY NOA No.: 12-0222.02 JAPPROVED1 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 1 of 7 t ROOFING ASSEMBLY, APPROVAL Category Roofing Sub-Cateaorv: Roofing Tiles Material: Concrete Deck Tvue• Wood 1. SCOPE This NOA approves a system using Barcelona 900 Concrete Roof Tile, as manufactured Boral Roofing LLC in Lake Wales, FL. and described this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable_ Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall be done as a moment based system.. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Barcelona 900 1= 17". TAS 112 High profile, interlocking, one-piece, 'S' w = 13", shaped, high-pressure extruded concrete roof Y? thick tile equipped with three nail holes. For direct deck or battened nail -on, mechanically fastened, mortar set or adhesive set applications. Trim Pieces Length: varies TAS -112 Accessory trim, boosted Barcelona, concrete Width: vanes ` roof pieces for use at hips, rakes, ridges and varying thickness valley terminations manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 2.1.1. Lake Wales, FL. 2.2 SUBMITTED EVIDEWCE: Test Agency Test Identifier. Test Name/Report Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 ` Appendix III TAS '102 & TAS 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix Il TAS 108(Nail-On) Redland Technologies P0402. Withdrawal Resistance Sept. 1993 Testing of screw vs. smooth shank nails Redland Technologies Letter Dated Aug. 1, Wind Tunnel Testing Aug. 1994 1994, TAS 108 (Nail -On) NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 2 of 7 t t t Redland Technologies P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Professional Service Industries, IC -1320-94 Physical Properties Feb. 1995 Inc. TAS 112 The Center for Applied 25-7688-3 TAS 101 (Adhesive Set) June 1996 Engineering, Inc. 25-7688-10 TAS 101 (Mortar Set) July 1996 The Center for Applied 25-7688-5 Static Uplift Testing June 1996 Engineering, Inc. TAS 102 (3" Headlap, Nails, Direct Deck, New Construction) The Center for Applied 25-7688-4 Static Uplift Testing June 1996 Engineering, Inc. TAS 102 (4". Headlap, Nails, Clips) Celotex Corporation 520111-3 Static Uplift Testing Dec. 1998 Testing Services 520191-2-1 TAS 101 March 1999 Walker Engineering; Inc. Calculations Aerodynamic Multiplier March 1999 Walker Engineering, Inc. Calculations Two Patty Adhesive Set April 1999 System Walker Engineering, Inc. Evaluation, 25-7183 March 1995 Calculations Walker Engineering, Inc. Evaluation 25-7094 February 1996 Calculations Walker Engineering, Inc. Evaluation 25-7496 April 1996 Calculations Walker Engineering, Inc. Evaluation 25-7584 December 1996 Calculations 25-7804b-8 25-7804-4 & 5 25-7848-6 Walker Engineering, Inc. Evaluation Restoring Moments Due to February 2007 Calculations Gravity Nutting Engineers 122 TAS 112 January 2007 NOA No.: 12-0222.02 Expiration Date: 04/26/17 " Approval Date: 04/19/12 Page 3 of 7 3. LIMITATIONS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set the applications, a static field uplift test shall be performed in accordance with TAS 106.' 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterlytest in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayments shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood .deck applications. Minimum deck requirements shall be in compliance with the applicable Building Code. 4. INSTALLATION 4.1 Barcelona 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Wejght;(W) and Dimensions (I x w) Tile Profile Weight -W (lbf) Length-1(ft) Width -w (ft) Barcelona 900 11.5 1.417 1.08 Table' 2: Aerodynamic Multipliers -X (ft ) Tile.. Profile (ft) Batten Application (ft3) Direct Deck Application Barcelona 900 ' 0.289 0.313 Table 3: Restoring Moments due to Gravity - Mg (ft-lbf) Tile Profile 2"•12" 3"•12" 4"•12" 5"12" 6"•12" 7"•12" or greater Barcelona 900 Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.28 8.13 1 7.21 '&05— 7.10 1 7.93 1 6.96 7.78 1 6.79 7.61 1 6.61 7.40 NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 4 of 7 Table 4: _ Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nall -On Systems Tile Profile Fastener Type Dlrect Deck (min 16/32" plywood) Direct Deck (min. 19/32' plywood) Battens Barcelona 900 2-10d Ring Shank Nails 28.6 41.2 19.4 4 Medium paddy placement of 2d r: rris ofRq! oTM.. 1-10d Smooth -or Screw Shank Nail 5.1 6.8 2.8 2-10d Smooth or Screw Shank Nails 6.9 9.2 7.3 1'.#8 Screw . 20.7 20.7 18.1 2 .#8 Screws : 43.2 43.2 29.8 1-10d Smooth or Screw Shank Nail Field Cli 23.1 23.1 19.0 1-10d Smooth or Screw Shank Nail Eave Clip) 29.3 29.3 24.0 2-10d Smooth or. Screw Shank Nails Field Clip) 27.6 27.6 38.6 2-10d Smooth or Screw Shank Nails Eave Clip) 38.1 38.1 41.8 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Adhesive 29.3 1 See manufactures componentapproval fdrinstallatioh recluirements. 2 Dow Chemical TileBond Average weight per patty 10:7 grams.. Pol oam Product Inc. Average ei ht . er,. a ' 8 rams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Barcelona 900 Polyfdarh Pol Pro'M 66.5 Polyfbam Pol frim 38.74 3 Large paddy placement of 6 rams of Pol ProTm. 4 Medium paddy placement of 2d r: rris ofRq! oTM.. Table 7: Attachment''Resisti nce Expressed as a Moment - Mf(ft-lbf) for Mortar Set -Systems Tile Profile Tile Application Attachment Resistance Barcelona 900 Mortar Set'. 24.5 5. Tile-Tite Roof Tile Mortar . NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 5 of 7 5. LABELING 5.1 All tiles shall bear the imprint or identifiable. marking of the manufacturer's name or logo as detailed below, or following statement: '•'Miami -Dade County Product Control Approved". LABEL FOR BARCELONA 900 TILE (LAKE WALES FL PLANT 2) LOCATED'UNDERNEATH TILE 6. BUILDING PERMiT REQUIREMENTS 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance: 6.1.2 Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this system. a A ti r NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 6 of 7 m BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE 5/8 " NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 7 of 7 t M u m BARCELONA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE 5/8 " NOA No.: 12-0222.02 Expiration Date: 04/26/17 Approval Date: 04/19/12 Page 7 of 7 MIAMb=UUM ® MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC -RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.aov/economv 3M Company 3M Center Building 0220-05-E-06 St. Paul, MN. 55144-1000 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of thio. Florida Building Code. DESCRIPTION: 3Mrm 2 -Component -Foam Roof Tile Adhesive AH -160 LABELING: Each unit shall bear a permanent label with .the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved,", unless otherwise noted herein. RENEWAL of this NCA shall be considered=aftef a renewal application has been filed and there has been no change in the applicable building code negativelyaffeetingthi performance of this product. TERMINATION of this NOA will occur'after, the.expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product p process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any :other.purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOAH ADVERTISEMENT: The NOA number preceded by th�'words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any,portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the jobsiteat the request of -the Building Official. This NOA revises NOA 12-0228.18 and consists. of.pages 1 through 11. The submitted documentation was reviewed by Juan E. Collao; R.A. NOA No.: 13-0502.02 Mu4ht IMPROVED MCoExpiration Date: 05/10/17 Approval Date: 12/12/13 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves 3MTM 2 -Component Foam Roof Tile Adhesive AH -160 as manufactured by 3M Company as described in Section 2 of this Notice of Acceptance. For the,, locations where the design pressure requirements, as determined by applicable building code, does not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127, for use with approved flat, low, and high profile roof tiles system using 2 -Component Foam Roof Tile. Adhesive AH -160. Where the attachment calculations are done as a moment based system for single patty placement; and as an uplift based system for double patty systems PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions '.Test Specifications 3MTM 2 -Component Foam N/A. TAS 101 Roof Tile Adhesive AH - 160 Foam Dispenser RTF 1000 N/A ProPack® 30 & 100 N/A Product Description Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS 1VMANUFACTURE0111 Any Miami -Dade County Product Control .Accepted -Roof Tilo Assemblyhaving a current NOA which list moment resistance values with the use of �-Component;Foam Roof Tile Adhesive AH -160 roof tile adhesive. MANUFACTURING LOCATION: . 1. Tomball, TX. PHYSICAL PROPERTIES: Prove Test Results Density ASTM D 1622: L6 lbs./ft.' Compressive Strength ASTM D -1621, 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile Strength . ASTM D 1623 28 PSI Parallel to rise Water Absorption ASTM D 2127. 0.08 Lbs./Fe Moisture Vapor Transmission ASTM E 96 3.1 Perm/ Inch Dimensional Stability ASTM D 2126 +0.07% Volume Change @ -40° F., 2 weeks +6.0% Volume Change @I 580F., 100% Humidity, 2 weeks Closed Cell Content ` " ' ASTM D 2856 ,Y 86% Note: The physical properties listed above are presented has typical average values as determined by accepted ASTM test methods and are subject.to normal manufacturing variation. APPROVED NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 2 of 11 I I I EVIDENCE SUBMITTED: I Test Aaencv Test Identifier Test Name/Reno Date Center for Applied Engineering #94-06_,0 TAS 101 04/08/94 257818 -IPA TAS 101 12/16/96 25=7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB -589-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 5284541-2-1 TAS 101 10/23/98 528434-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 ,520109-3 520109-6 520.109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statemeat: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal ,as shown below. MIAM14=E c0UWTY 1111191 I • L 3. 3M"° 2 -Component Foam Roof Tile Adhesive -AH -160 shall solely be used with flat, low, & high tile profiles. 4. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 5. Roof Tile manufactures acquiring acceptance :for the use of 3M"° 2 -Component Foam Roof Tile Adhesive AH - 160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 6. All products listed herein shall have a quality -assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. NOA No.: 13-0502.02 MIAMI•DAD; COUNTY Expiration Date: 05/10/17 JAPPR Approval Date: 12/12/13 Page 3 of 11 INSTALLATION: 1. 3MTM 2-Component Foam Roof Tile AdhesiveAH-160; may be used with any roof file assembly having a current NOA that lists uplift resistance values with the use off3MTM 2-Component Foam Roof Tile Adhesive AH-160. 2. 3MTM 2-Component Foam Roof Tile Adlhesive'AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall provide sufficient attachment resistance, expressed as an uplift based system, to meet: or exceed the uplift resistance determined in compliance with Miami-Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA.- 3. OA:3. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and 3M Company's 3MTM 2-Component Foam Roof Tile Adhesive AH- 160 Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by 3M Company. 3M Company shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component andthe "B" component shall be maintained between 1.0-1.15 (A): 1.0 6. 3MTM 2-Component Foam Roof Tile Adhesive AH-160' shall be applied with Foam Dispenser RTF 1000 or ProPack® 30 & 100 dispensing equipment onlq' 7. 3MTM 2-Component Foam Roof Tile Adhesive AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after 3MTM 2- Component Foam Roof Tile Adhesive AH-160 has been dispensed. 9. 3MTM 2-Component Foam Roof Tile Adhesive AH- 1§0,placement and minimum patty weight shall be in accordance with the 'Placement Details' herein, Each:generic tile profile requires the specific placement noted herein. MIAMFnADE coUN7Y NOA No.: 13-0502.02 J JAPPROYEDI Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight Eave Course - Flat, Law, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High. Profiles #1 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile #2 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy 'head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two .Piece' ' ' 65-70 sq. inches 34 grams under pan e LABELING: All 3MTm 2 -Component Foam Roof Tile. Adhesive AH -160 containers shall comply with the Standard Conditions listed herein. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or. applicable: building code in order to properly evaluate the installation of this system. NOA No.: 13-0502.02 owo; c,1 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 5 of 11 NA thrreqWrough ra eenre underlayment OQ o 10 o t. loin. :*2'1 through plastk cement m required) ADHESIVE PLACEMENT DETAIL # 1 r iacW"(Befleath Nee, Wthrough pkMc (when required) Poddy.ieeneath nfeT . undedayment „' y o 10h4x 2 in. wide Battens optional o Eavecourw Fasda W. phode 101n. 2in. Eavedosure Drlp edge . FlaVLow. Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1; Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. I Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile L. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. . Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 c1112) square inch adhesive contact with the underside of the tile. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 6 of 11 �5 ADII ESIVE PLACEMENT DETAIL # 2 Flat/Low Profile Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the 'underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. a 3. Continue, in same manner. Insure approximately 10" (64.5 cm) -12 (77.4 cm) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) — 23 (148.4 cm) square inch adhesive contact with the underside of the tile. 2. At.the second course, apply a minimum 2" (50.8mm) x7' (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. i Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm2) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 7 of 11 W ADHESIVE PLACEMENT (DETAIL # 2 (CONTINUED) Nall through plastic (when required) Paddy (Beneath Tile) underlayment 7i 2 irr. Battens optional , s\ Eave course as<ia vkephole loin. 2 in. "closure Drip edge High Profile / Single Pan Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm2) - 19 (122.6 cm) square inch adhesive contact with the underside of the tile. F NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 8 of 11 ADHESIVE PLACEMENT DETAIL # 3 1. On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat tile or under the pan portion of the tile for low or high profile tile closest to the overlock of the tile being set. Leave approximately 4" (10 1.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 int (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a4" (101.6 mm) x4" (101.6 mm) x 1 " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course tile to be installed. Insure approximately 8-9 int (51.6-58.1 cm) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 9 of 11 ADHESIVE PLACEmFNT DETAIL # 3 (CONTINUED) 3. Also apply a 211(50.8 mm) x 4" (101.6 mm) x %" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.,1 cm2) - 11 (71cm2) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cm) - 9 (58.1 cm2) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 10 of 11 1) Place enough adhesive to achieve 65� M contact w8h the pan tile. 2)Turn covers upside down. Place adhesiv to 7 In. horn outside edge of cover tile. Then install the We. Ensure 20 to � 25 sq. In. contact area. _ Uagment i- , ": �-_- ADHESIWE PLACEMENT DETAIL TWO PIECE BARREL Steep pitch appiicaft (when required) 0 ttno�rshown)�Bd OptimalPoint-up Mortar iNeepholeFaon longitudinal edges.oftlie. Remove top portion of the save course covrtile.Ahutto second course of pan dies. Ensure ewe end of pan and coverti)es are flush at save line. Two Piece Barrel - High ProftTile , Two Piece Barrel (Cap and Pan) Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm2) — 70 (451.6 cm) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 min) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge, of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cm2) 25 (161.3 cm) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" 001.6 mm) nallers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END- OF THISACCEPTANCE �(M7A P P �RO V E DI NOA No.: 13-0502.02 Expiration Date: 05/10/17 Approval Date: 12/12/13 Page 11 of 11 TGFU.R1306 - Roofing Systems Crushed stone or slag are suitable alternates for gravel in any of the Gass A, B or C systems listed. rage /. oz D / Structural cement fiber building units are considered suitable to be included as a deck in the following Gass A; B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Gass A, B or C systems does not adversely affect the rating. The use of Win. minimum thick gypsum board is an acceptable altematd for minimum insulation over C-15/32 thick roof decks. The use of polystyrene Insulation board between minimum %-In. thick partite board and deck with rosin paper (perlite/rosin paper/polystyrene/perlits) Is a suitable a{temate for polyisocyanurate board in the following Class A, B or C Systems. "EnergyGuardTM RA" or "Tapered EnergyGuardm RA" or "EnergyGuard'" Composite RA" may be substituted for any Atlas Roofing Corp. polyisocyanurate insulation in any of the following Classifications. .Trumbull "Perma Mop" rftay be utilized with any of the following "Asphalt Felt System with Hat Roofing Asphalt". "GAFGLASS #80 Premium Base Sheet" may be used In any of the following systems. "GAFGLASS Rex Ply 6" and "TN -Pty® Ultra -Flexible Ply 6" are suitable alternates to "GAFGLASS Ply 6 0. "GAFTEMP Perrnalite Recover Board" may be used in lieu of any perlite insulation in any of the following NC-ClassiflcatlonS. Unless otherwise indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "Firesh d MB" at 2% to 3-gal/100- R2. "RuberoldS Dual Smooth" may be used as an alternate to. "Ruberoid* Mop Smooth" or °Ruberold® 20" or °Ruberold® 20 HT" "RuberoldS Mop Smooth 1.5" may be used as an altemate to "RuberoldG Mop Smooth" Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Rubemkl@ Heat Weld" SBS roofing membrane may be used in lieu of "RuberoldG Mop" SBS products in any applicable Gasstflcatlon. Clams A 1. Dada C-15/32 Indlne: 3 Insulation (Optional): — One or more layers perllte or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or periibe/urethane composite or wood fiber/polylsocyanumte composite or phenolic, any thickness. Ply Shasta — Three or more plies Type G1 or "GAFGLASS Ply 4" or "Tri -Ply® Ply 4" or "GAFGLASS Ply 6" hot mopped. Surfaeingr Gravel. 2. Decla C-15/32 Incline: 2 Insulation (Optional): — One or more layers perUte or wood fiber or glass fiber or polyisocyanurate or urethane or periite/poKsocyanuraie composite or periite/urethane composite or wood fiber/polylsocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more piles Type GI or "GAFGLASS Pty 4" or "Tri-PiyG Ply 4" or "GAFGLASS ply 6". Cap Shef: — One ply Type Q3 "GAFGLASS Mineral Surfaced Cap Sheet" or "Tri -Ply* Mineral Surfaced Cap Sheet " or "GAFGLASS EnergyCap'" BUR Mineral Surfaced Cap Sheet." 3. Deck: NC Incline: 2 Insulation (Optional: — One or more layers peri te, wood fiber, glass fiber, pclyisocyanurate, urethane, perUte/PolYlsocYanurate composite, periite/urethane composite, wood fiber/polylsocranurate composite, phenolic, 2 -in. maximum. Ply Sheets — Two or more piles Type G1 "GAFGLASS Ply 40, 'Tri -Ply@ Ply 4" or "GAFGLASS Ply V. Cap Shaft— One ply Type G3 "GAFGLAS® Mineral Surfaced Cap Sheet" or'Tri-Plye Mineral Surfaced Cap Sheet" or "GAFGLASS EnergyCap'" BUR Mineral Surfaced Cap Sheet." 4. Decks C-15/32 Incline: 1 Slip Street (Optional): — Red rosin paper, nailed to deck. Insuhditn (Optional): — Any thickness peri to or wood fiber or glass fiber or polyLsocyanumte mechanically fastened or adhered with OMG Inc. "OlyBond Fastening System" or any UL classified insulation adhesive. Base Shwb — One ply Type G2 "GAFGLASS *75 Base Sheet" or rri-Ply@ *75 Base Sheet" (may be nailed). Ply Sheet: — One or more plies Type G1 "GAFGLASS Ply 4" or "Tri -Ply@ Ply 4" or GAFGLrSG Ply 6". Cap Sheet: —.One ply Type G3 "GAFGLASS Mineral Surfaced Cap Sheet" or "Tri-Piy® Mineral Surfaced Cap Sheet" or "GAFGLASS hupJ/daubase.ul.com/cgi-binDM/template/LISEXT/l FRAME/showpage.ht ml?name=... 10/27/2013 M4W • pggg��s�+ �'-DADfPi��i.�VWlaY�9p MEW 11805 3w 26 Str M Room 208 A&PAR (W RE TORY AM 1CCT®NIC USOIIRC +'DMhW66 Florida 33175-2474 HARD AND CODE A DMVM7R TlJ.EDN 1DPMION T (786)315-259€9 F (78b) 315-2599 liO FAC (NOA).,.. w.aseia�cla3asP .ae!rleconaageay 3AF .361. Alps Road a Mayne, NJ 07470 5COPEe 'leis NOA is being issued wader the applicable rules and regulations governing the use of consauctiotf girls. The ocumentation submitted has been: reviewed and accepted by AIiinii ode County RIA -Product Control Section to be sed in Miami Bade County and ocher areas where allowed by 1ho Authority Raving Jiwisdicdon (AHJ). . his NOA shall not be valid atter the expiration daft sued b6low. The' -Dade' County Control section In Mmm' Dade County) and/or the AHJ (in areas other than Miami Dade Cour, ) reserve the right to have this roduct or material tested for quality assurance: purposes. If this product or maty ' fails to perform in the accepted tanner, the rraanufacur will incur the expense of such testWg and the AHJ may! immediately revoke, modify, or xsperrd the use of such product or. ithin.iheFinrisdicopn, RER reser�res right to revoke this acceptance, it is determined by tat I�Odie County Product Control Se�,tion that this prodwt or material fails to meet the ;quirernents of the applicable building his product is approved as deseaed lheneany rind has lin designed to comply with the Florida. Building Cade icluding tie High V'elocity.Hurricane Zone of the Florida Building Code. 1Es ON'o GAF Conventional liluf Up Awf System for -Food A Gm Each unit shall beat a permanent label with tihel Manufacturees name or logo, chy, state and following atement: "Miami -Dade County Product Control Ap*ved", unless otbervAse noted. rein. ENEWAL of this NOA shall be considered dter' a renewal -app lkafion has been bled and Ihere has been no change the applicable building code negatively affecting the performance of this.product. ERKWATION of this NOA will occur after the expiration date or if there has been a revision or change in the hterials, use, and/or manufacture of the prochict or process., Miiuse of this NOA as an endorsement d any produce, r sales, advertising or any other ptnrpos shall automaticallyternaLe this NOA. Failure to complywith any section this NOA shall because for termination ai d•i oval ®f NOA.:, .. D TT 10 T: The NOA climber 'preceded.by he,words ,MiamiDade Counly, Florida, and followed by the piration ion date may be displayed an advertlsitig lite': I 'ai y. To tion of the NOA irs displayed, then it sha11 be donee its entirety. isPECTION: A co of this entire NOA shall be. y . copy provacled to�ihe user b the or its"dastxabutors said hll be available for inspection at job site at the request of the�uilding Offie al. is NOA revises and renews NOA No. 07-121409 consists of paw 1 through 17. e submitted documentation was reviewed by Juana E.'Collao, R.A.' NOA No.: 0.0424.09 Expiration Date: AIAW14 .Approval Date: 10/31/13 Page I of 17 Deck Type t: Deck Descriptiob: System Type E: t Wood,No&insukdxd /.7 orateaterpiYwood or-woodp decks Base shed mechanically ftstmed. All General and Systm LhdbdDi!s SW Fire Barrier: FiwWTm Fire B.Wiff CoatitS Nie�wShiele Fire Resistant Roof Deck Protection or (optional) semo&Tm Gypsum Fiber Roof Md%L Base sheet GAFOIAe #80 MtimaTm Base Sheet, Stratawme Elimin M,Nailable Venting Base i4o=ie 20, itubmie si§R Heat weieu smooth or Ruberoie SBS Hed Sheet, Wektru,25 base sheet mechanically fastened to dock as dew.nl3ed below, Fasteaft Options: GAFMAS* Ply 4, GAFGLAS® Fj,`xpjyTm 6, GAFGLAe #75 Base Shedt of MY Of above tin at a base,sheets anached to deck with approved annular ring SIWA n" and caps fiwener spacing Of 9" O.C. at the lap staggered and in two rows 12" o.c. in the field- . (Mwdmaara.Desi rt Pressure -4Spo; See GexeWLhn&AOR #7) GAFGILAS@�PlY'.AAjA.FGL,AS. fjexPJyT9 60 #75 Base Sheet or any Of abOve baa sheets attached to dwk-;witfi Dill TecTu 412 Fastener or Drill-Tedm #14 and Ikill- TecTm 3- Steel Plate,; VzWTedm AccuTrae Flat Plate or Drill -Tcdm A=Trae Recesses Me 12" o.C. in 3. rOVM ;One row is in the 2" side lap. 116 other rows are equally spacedapprdx sheet approximately irb.c. in the field of the (Mwdm= Datu Pressawe -45 isf, See General L&dAWOR C9 CAFGI.Ae )FI= PWTm 6, GAFGLAS® #75 Base Sheet orany of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener SPaCMg of 9"o.c.-atthe 4" lap staggered and ,mtw9 rows 9" o.c. in;the field. (Mw&xwnDeAgnPreisare-52.5'p#; See &nwaILhn&sdon #7) :S . heat, Ruberoje2o, Ruberoje mop smooth, base sheet GAFGLAS* #80 UlfitnaTm Ban' attached to deck with approved 11/4" annular ring shank nails and inverted 3" steel plate at a fiaten6r spacing of 9" o.c. -at the,47 lap: and in -two rows SUOgered.with a fastener spacing of 9" o.c. in then center of the membIrabe- General Ljm�n #7) (Afxdwmt Design PFe See cMW GA . F7.LASOW75..Bw-$h t,oro ;,of above base sheets attached W deck with Drill-Tec"m Plate, Drill-Tedm #12- wftneroiDrill Toc7r,#l4. a,generandDrill-Tedm3 Steel AccuTrae Flat -Plate or Drill-Tedmi AccuTrae Recessed Plate 12:" o.c. in 4 rows. One row. is in. the 21* side lapj The other rows are equally spaced approximately 9. o.c. in the Iield-,of the (MwcjDeikn Premare -0 of, See Ggjwd Lbnka#on #7} Any, of above Base sheets aftwhed to deck approved annular ring shank nails and 3 inverted Drill-Tedm insulation plitpsot a &stener spachig6f 9" o.c. at the V lap staggered in two rows 9" in thefield. #7) (M*Vbmm .6ed9n Prewnre -60 psiSee General Liar on NOA No.: 13-0424.09 FXptmtjon Date. -11/04/14 Approval Date: I0SI/13 Page 15 of 17 r 4 GAFGLAS®I#75 Base Sheet or apy of above base sheets attached to deck with Drill-TecTu #12 Fastener or Drill TecTu #141;asteaner and Drill TecTM 3" Steel Plate, Drill-TecTm AocuTrac® Flet Plate or Drill-TeOrk AcwTrac® Rwessed Plate 8" o.c. in 4 rows. One row is in the 2" side lap. The mer rojv�s aTe equally spaced approximately 9" o.c.M the field of the sheet. DCsigra Pr urn —7�psf Sce General L fon #7J Ply Sheet t. One or more plies of GAFGL,AO 1'1y 4• or WOLAS® #80 Ultima Base Sheet adhered m a full mopping of approved *halt applied wilhin the EVT 'range and at a rate of 20-40 lbsJsq. x Cap Sheet:{Optional} One ply of GAFG W'w Mineral Surfaced Cap Sheet or GAFG%ASe EnetgyCapTu BUR Mineral Surfaced Capsheet adhered in a full° mopping of approved asphalt applied withm.•the EVT range and af a rate of 20-40 lbsJsq. S '000821. on granular surfaced membranes; required for smooth membrane& Chosen componets most be applied wording to manufacturer's apocation instructions 1, Gravel -or slag applied at 400 lbsJsq. and 300 lbsJsq. respectively in a flood coat of droved asplslt at 601bsJsq. 2. Topcoat' Surface 86LSB appliedat Ito 1.5 galJsq. maximum Design Pressure: See Fastening: Above t WOOD DECK SYSTE=M LIlVJD.TATIONS: I A slip slieet is required with GAFGLASn Ply 4 and GAFPG Ae Flex P1yTm 6 when used as. a mechanically fastened base or anchor sheet. I F 2. Minimum 1/47 Dens DeckTm Roof Board or %? Type X gypsum ward is acceptable to be installed directly over the wood deck. GENERAL LMTATIONS: 1. Fire classification is not part of this acceptance; refer to h current Approved Roofing Materials Directory for fire ratings of this proauct 2. Insulationumy be installed in multiple layers. The first jajer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a frill mopping of approved asphalt applied within the EVT range and at a rate of 20401bsJsq., or mechanic afirstdached using the fastening pattern of the top layer 3. All standard panel sizesare acceptable for mechanical attachment When applied m approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery: board insulation panel is required on all applications over dosed cell foam insulations when the base sheet is fully mopped. If no recoverybo,ard is used the base. sheet shall be applied using spot mopping with. approved asphalt 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area,* of ventilation. Encircling of the strips is not acceptable. A b" brisk shall be placed every+ 12' is each ribbon toallow cross ventilation. Asphalt application of either system shall be at.a minimum rate pf 12. lbsJsq. Note: = Spot attached systems shall be limited to a maAmnm design prewnre of -45 PSE 5. Fastener spacing for insulation attachment is based on a h4inimurn Characteristic Force (F) value of 275 lbf., as tested m compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/baso sheet or membrane attachment is based on a minimum fastener resistance vahre in conjunction with the maximi}ni design value listed within a specific system. Should the fastener resistance be less than that requited, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application. Standards TAS 105 and calculations in. compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 11.7. Calculations prepared, signed and !sealed by a Florida registered Professional Engineer, Registered Architect or Rq*cred Roof Consultant (When this limitation is specifically referred within this NOA, General U m nation #9 will not be applicable.) 8. All aftachment and sizing of perimeter milers; metal profile, and/or flashing termipation designs shall conform to Roofing Application Standard RAS 111 and applicable wird load requirements. 9. The maximum designed pressure limitation listed shall be Applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhance. pressure zones (i.e. perimeters, extended corners and cornets). (When this limitation is specifically referred within this NOA, f enera!_Limitatiou #7 will nht be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with -the Florida. Building Code and Rule 9N-3 of the Florida Adrhinist stive Code. END OF tMS A�A�EPTA1oTCE NOA No.: 13-M24.09 Expiration Date: 11/04/14 Approval Date: 10/31/13 Page 17 of 17 Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD- A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit a - sence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. LSignature Signature V //-OWNERorAGENT The foregoing instrument was acknowledged before me this D"-7 day of 0 lw 20 M . by kci7.). who is personally known to me or who has produced as Identification and who did take an oath. NOTARY PUBLIC: Seal: 3N-0153 MY (O hMISSION #FF091428 EXPIRES February 10, 2018 CONTRACTOR The foregoing instrument was acknowledged before me this 07 day of Ajn�2 V . 20 kA . by -who is personally known to me or who has produced as identification and who did take an oath. NOTARY PUBLIC: Seal: flefl��i�k�F6�Y9�Bfl��iMM6B�kUb�kM�k&�kBeRM�FM8�9� �RAtN4uR+Mb�N �MiM3 8�&N�Y�Mffi�k4MMMM�P�Yd�89�Y&�k"flaR&+E&+FB�MrteU�Mtle9�M APPROVED BY Plans Examiner Structural Review (Revised02/24/2014) TRAISY GONZALEZ Y COMMISSION #FF091428 EXPIRES February 10, 2018 Zoning Clerk Maya' SAW411alfe R4 D 10050 NE 2nd Ave* Miami Shores, FI 3313 664"' Phone 305-795-2204; Fax 305-756-8972 OWNERS'S AFFIDAVIT OF EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village Building Department Date: 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: 3 Property Address: 6 3� 1y C— ` ? 6j ' o Roofing Permit Number: Dear Building Official: certify that I am not required to retrofit the roof to wall connections of my building because: he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Iluilding Code (1994 SFBC) Signature Print Name State of Florida County of Dade The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this (7-7 day of I� ipNZALEZ `• IVII 00 6N 0F091428 ?r EXPAN FebrUft 10, 2018Notary Public, Sate of Florida at Large n �7)150 Defld ats seNlae.00m When the just valuation of the structure for purpose of ad FBC nor a 1994 SFBC. Then you must provide a building application from a Gener�l Contractor for the F�oefto Wall ' connection ' Hurricane Mitigation Summary Report Property Information Folio: 11-3206-017-1880 Property Address: 639 NE 97 ST < Owner JUAN C DIAZ &W JENNIFER Mailing Address 639 NE 97 ST MIAMI SHORES , FL 33138-2470 Primary Zone 1000 SGL FAMILY - 2101-2300 SQ Primary Land Use 0101 RESIDENTIAL - SINGLE FAMILY 1 UNIT Beds / Baths / Half 2/2/0 Floors 1 Living Units 1 Actual Area 1,612 Sq.Ft Living Area 1,248 Sq.R Adjusted Area 1,430 Sq.Ft Lot Size 9,750 Sq.Ft Year Built 1949 Assessment Information Benefit Type 20141 Year 2014 2013 2012 Land Value $204,930 $181,401 $139,656 Building Value $96,954 $96,954 $108,928 XFValue $1,604 $1,618 $1,982 Market Value $303,488$279,973 $250,566 Assessed Value I $161,259L___$158,8671 $25,000 $156,212 Benefits Information Benefit Type 20141 2013 2012 Save Our Homes Ca Cap Assessment Reduction $142,238 $121,106 $94,354 Homestead Exemption $25,000 $25,000 $25,000 Second Homestead Exemption $25,000 $25,000 $25,000 Note: Not all benefits are applicable to all Taxable Values (i.e. County, School Board, City, Regional). Short Legal Description MIAMI SHORES SEC 4 AMD PB 15-14 LOT17&E1/2LOT16BLK101 LOT SQE 75.000 X 130 OR 18122-4889 0598 1 Generated On: 8/7/2014 Taxable Value Information Previous Price OR Book Qualification Description Sale 20141 20131 2012 County $142,500 18122-4889 2008 and prior year sales; Qua[ by exam Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $111,250 $108,867 $106,212 School Board of deed ExemptionA/alue $25,000 $25,000 $25,000 Taxable Value 1 $136,250 $133,867 $131,212 City $70,000112549-1786 2008 and prior year sales; Qual by exam Exemption Value $50,000 $50,000 $50,000 Taxable Value $111,250 $108,867 $106,212 Regional Exemption Value $50,000 $50,000 $50,000 Taxable Value 1 $111,250 $108,867 $106,212 Sales Information Previous Price OR Book Qualification Description Sale Page 05/01/1998 $142,500 18122-4889 2008 and prior year sales; Qua[ by exam of deed 03/01/1992 $93,500 15444-0390 2008 and prior year sales; Qual by exam of deed 08/01/1990 $0 00000- Qua[ by exam of deed 0 0000 06/01/1985 $70,000112549-1786 2008 and prior year sales; Qual by exam of deed The Office of the Property Appraiser is continually editing and updating the tax roll. This website may not reflect the most current information on record. The Property Appraiser and Miami -Dade County assumes no liability, see full disclaimer and User Agreement at http://www.miamidade.gov/info/disclaimer.asp (http://www.miamidade.gov/info/disdaimer.asp) Version mawe S&W 1/&14 a4 2)CA446mewr 10050 NE 2nd Ave Miami Shores, FI 33138 �j Phone 305.795.2204; Fax 305-756-8972 www.miamishoresvillage.com RE: Permit #9� I- -4- �140 INSPECTION AFFIDAVIT M��— �Z , licensed as a (n) Contractor/ Engineer/ Architect, (Print name and circle License Type) FS 468 Building Inspector License #: �'�� C) Z-4- 6 D On or about C /9>`,00 % , I did personally inspect the roof deck nailing and/or (Date & time) f secondary water barrier work at 6°3% NI- f 7si ��Wl®.6A 1- 3,3139 (Complete Job Site Address) Based upon that examination I have determined the installation was done according to the Hurricane Mitigation Retrofit -N -,ate ,� ter, S 8F .S) Signature State of Florida County of Dade: The undersigned, being the first duly sworn, deposes and says that he/she is the contractor for the above property mentioned. Sworn to and subscribed before me this Z 3 T'Y day of Notary Public, Sate of Florida at Large NORgISY G011 ZA EZ F My COMMISSION #FFo91428 EXPIRES brUary 10, 2018 398.0183 �Ir�rLa .�_.__ . 'General, Building, Residential, or Roofing Contractors or any individual'certified under W8 F.S. to make such an inspection. Include photographs of each plane of the roof with permit # and address # clearly shown marked on the deck for each inspection CIVIL Reileh Engineering Corp. (Consulting Engineer) 2370 S.W. 123 Avenue Miami, Florida 33175-1174 Tel: 305-823-8008 / 305-397-6414 EN6INEER Fax: 305-823-3300 / 305-884-8834 Website: www.reilehengineering.com September 23, 2014 Florida Roof Tech 2730 West 78 Street Hialeah, Florida 33016 Project: ROOF TILE UPLIFT TEST REPORT Residential Home 639 Northeast 97 Street Miami Shores, Florida Information provided by client: Permit Number: RF9-14-1960 Date Completion: September 19, 2014 Roofing Contractor: Florida Roof Tech Project Number: 14-0863 (Testing Laboratory Certificate # 11-0715.04) Dear Sirs; In accordance with your request and authorization, a representative of Reileh Engineering Corporation completed the Roof Tile Uplift Test at the above referenced project. This testing was performed in general accordance with Roofing Application Standard TAS No. 106 -- Standard procedure for field verification of the bonding of mortar or adhesive set tile system and mechanically attached, rigid, discontinuous roof systems. The total of the tested roof surface area was less than 10000 square feet, and the mean height of the roof is less than 40 feet above ground surface. The type of tile used for this project was reported to be Boral Barcelona Gold Dust Roof Tile. This tile was reported to have been foamed in place. At the time of our inspection, the entire area of the roof was examined for loose tiles. Not less than one (1) tile in ten (10) of all components in the field area and one (1) tile in five (5) of all tiles in the perimeter and comer areas were physically examined. A minimum of one (1) test per every two (2) squares in the field, one (1) test per square in the perimeter area, ridge caps and (1) in the comer areas were conducted. Reileh engineering Corporation appreciates the opportunity of assisting you in this project. If you have any questions or if we may be of further assistance, please do not hesitate to contact the undersigned. Respectfully submitted; Reileh Engineering Corporation �d Sonny Salleh, P.E.49014 Manager TILE UPLEFf TEST Residential Home 639 Northeast 97 Street Miami Shores, Florida Reileh Engineering Corporation — Project Number -14-0863 — Page 2 of 5 Report of TILE UPLIFT TEST for Residential Home 639 Northeast 97 Street Miami Shores, Florida Project Number: 14-0863 Test Number _ si Test Load. b=Fest Status' 1 35 Pass 2 35 Pass 3 35 Pass 4 35 Pass 5 35 Pass 6 35 Pass 7 35 Pass 8 35 Pass 9 35 Pass 10 35 Pass 11 35 Pass 12 35 Pass 13 35 Pass 14 35 Pass 15 35 Pass 16 35 Pass 17 35 Pass 18 35 Pass 19 35 Pass 20 35 Pass 21 35 Pass 22 35 Pass 23 35 Pass 24 35 Pass Reileh Engineering Corporation — Project Number - 14-0863 — Page 3 of 5 -41 Tij, stivaltir Teit-L"aad' b °i.. 'Ts, Status • 25 35 Pass 26 35 Pass 27 35 Pass 28 35 Pass 29 35 Pass 30 35 Pass 31 35 Pass 32 35 Pass 33 35 Pass 34 35 Pass 35 35 Pass 36 35 Pass 37 35 Pass 38 35 Pass 39 35 Pass 40 35 Pass 41 35 Pass 42 35 Pass 43 35 Pass 44 35 Pass 45 35 Pass 46 35 Pass 47 35 Pass 48 35 Pass 49 35 Pass 50 35 Pass 51 35 Pass 52 35 Pass 53 35 Pass 54 1 35 Pass Reileh Engineering Corporation — Project Number - 14-0863 — Page 4 of 5 Test Number 'I`est Luad b ;Test Status _ P • 55 35 Pass 56 35 Pass 57 35 Pass 58 35 Pass 59 35 Pass 60 35 Pass 61 35 Pass 62 35 Pass 63 35 Pass 64 35 Pass 65 35 Pass 66 35 Pass 67 35 Pass 68 35 Pass 69 35 Pass 70 35 Pass Test 1-17 Corner, 18-24 Ridge Caps, 25-40 Perimeter, 41-70 Field Reileh Engineering Corporation — Project Number - 14-0863 — Page 5 of 5 11;51' 1U MUM o l0005F 0 lana CAP TW LOCATION FIMP a 30 COUP - 110 5� MIUMP - 16 NO, T5f LOCA11ON P MN0T5 MOKeN 1U COUP m 11 MPJMMk i715TANM, a s 5' L 1X NOT 5 L0055L TLE P29i ; CAP ® I COUP ASA m VX V APPWX. ROOF 11;51' LOCA110N5 AN12 t71WN51ON5 14-0863