Loading...
RF-14-1593Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-216466 Scheduled Inspection Date: September 30, 2014 Inspector: Rodriguez, Jorge Owner: DORSON, BERNARD & GERMAINE Job Address: 10634 NE 11 Avenue Miami Shores, FL Project: <NONE> Contractor: MURPHY ROOFS tsunamg uepartment comments RE ROOF LOW SLOPE Permit Number: RF -7-14-1593 Permit Type: Roof Inspection Type: Final Roof Work Classification: Repair Roof Phone Number Parcel Number 1122320280650 INSPECTOR COMMENTS False Phone: (305) 892-1700 Passed Inspector Comments Failed Correction Needed ❑ Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. September 29, 2014 For Inspections please call: (305)762-4949 Page 5 of 31 Miami Shores Village Building Department 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 BUILDING PERMIT APPLICATION Permit Type: BUILDING JUL FBC 20 to Permit Noq — �-6q Master Permit No. ROOFING JOB ADDRESS: JOG 3V // City: Miami Shores County: Miami Dade Zip: Folio/Parcel#: Is the Building Historically Designated: Yes NO Flood Zone: OWNER: Name (Fee Simple City: I 1 I I f� Tenant/Lessee Name: Email: CONTRACTOR: Company Name: Address: 4 ® q 03 City: Qualifier Name: �c State Certification or Registration #: Contact Phone#: DESIGNER: Architect/Engineer: _ State: 0 _ �?L_35_ 961h / 0 1—� r Zip:iC/ Phone#: 3ci— /Y �I S qb"I 'Z— Certificate of Competency #:� �� �J% Address: Value of Work for this Permit: $ 6Square/Linear Footage of Work: / 1 Type of Work: UAddition DAlteration UNew URepair/Replace 09emolition Description of Work: Color thru tile: Submittal Fee $ Permit Fee $ 1 ci"; JCbCCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ i _� L� ' OC; Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State zip zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. �1 Signature Signature Owner or Agent 3` ev The foregoing instrument was acknowledged before me this .tel day of 20 q, by W ho ' ersonally kno to me or who has produced As identificatiQa�azd who did take an oath. Sign: Print: M17)% aftward Al�ti My CommissionmMM EE 898821 03121/2017 APPROVED BY O 11-� Contractor A The foregoing instrument was acknowledged beobe me this �` 1 day of aL-( '20 `� , by 1 °�'1�,Ja {JH who is personally known to me or who has progj,, ad iyy9 fv2� as identification and Nodid•take-4.. a\`1b•'•• sa ®/moi NOTARY PUBLIC: Q)., d w Sign: Print: My Commission Expires: Plans Examiner Zoning Structural Review Clerk (Revised 5/2/2012)(Revised 3/12/2012) )(Revised 06/10/2009)(Revised 3/15/09)(Revised 7/10/2007) �OR1D�' SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES — REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govern the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The wner's initial in the designated space indicates that the item has been explained. I. Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreem t between the owner and the contractor. 2. Renalling wood decks: When replacing roofing, the existing wood roof deck may have to be renaile in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. XCommon roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. /6 Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearan 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. A9 Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimetededge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accorda/nge with the requirements of Sections R4402, R4403 and R4413. (J� 7. ._Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It may be beneficial to consider additional venting which can result in extending the service life of the roof. Owner/Agents Signature Date Contractor Signa D e Revised on 7/9/2009 LD Miami Shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 OWNERS'S AFFIDAVIT Of EXEMPTION ROOF TO WALL CONNECTION HURRICANE MITIGATION RETROFIT FOR EXISTING SITE - BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES PERSUANT TO SECTION 553.844 F.S. To: Miami Shores Village BuildingDepartment Date: � 7 p 10050 NE 2nd Ave Miami Shores, FI 33138 Re: Owner's Name: g er w D 61"Wd D® r:5 ® i'x Property Address: 10103q 11 Awe M f lm I /Lor [, ? 3/ Roofing Permit Number: Dear Building IOffcii Ae,.r ') certify that I am not required to retrofit the roof to wall connections of my buildin cause: he just valuation for the structure for purpose of ad valorem taxation is less than $300,000.00. Please attach proof of ad valorem taxation. ❑ The building was constructed in compliance with the provisions of the Florida Building Code (FBC) or with the provisions of 1994 edition of the South Florida Building Code (1994 SFBC) Signature State of Florida County of Dade Print Name The undersigned, being the first duly swom, depokes and says that he/she is the owner for the above property mentioned. Sworn to and subscribed before me this 0941>> day of % 4.,e 4_2V l I/ Notary Public, Sate of Florida at Large • When the just valuation of the structure for SFBC. Then you must provlde a building al Revised on 5/21/2009 Notary Public State of Florida Howard Alt d i MY Car.... ion EE NMI Wagon Is equal to or more than $300,000.00, and the building was not constructed with FBC nor a 1994 a General Contractor for the Roof to Wall connection Hurricane Mitigation. Florida Building Code Edition 2010 High Velocity Hurricane Zone Uniform Permit Application Form Section C (Low -Sloped Roof System) Fill In Specific Roof Assembly Components and Identify Manufacturer (if a component is no used, identi as "NAJ System Manufacturer NOA No,: Design Wind From RAS 128 or Calculation Pmax1: f Pmax2: '747 Pmax3: 1047 Max. Design Pressure, From the Specific NOA System: '—ITZ ° V Deck: �. Type: i8&aA92=0 Gauge/Thickness, Slope: 1.-12- Anchor/Base .®2^AnchorBase Sheet & No, of Ply(s): Ancht ase Shee , astener/Bond' M Insulation Base Layer:�� Base insulation Size and Thickness: Fastener Spacing for Anchor/Base Sheet Attachment Field: —. oo @ Lap, # Rows . @ --oc Aj /10 Perimeter: 42 oc @ Lap, # Rows 7'" "OG Corner: " oc @ Lap, # Rows �, @ ° oc Number of Fasteners Per Insulation Board Field: Perimeter Comer Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter; Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter- Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. ���qt` ,1 ^Gj. Base Insulation Fastener/Banding material:��� Top Insulation Layer: N/'A A t,.gA4gx,c y FT. Para, Top Insulation Size and Thickness:O�lr% /oe� Heigl Top Insulation Fastener/Bonding Material: M ZA Base Sheet(s) & No. of Ply(s): AllylM---- Base Sheet Fastener/Bonding Material:40 of �Q Piy S et(s) & No. of Ply(s}: Ply Sheet Fas ding to ial: Top Ply 4.0— /y�r' 1AP45A-" Top Ply Fastener/Bonding Maters 5�, Surfacing: Allam T �a Mean Roof Height MIAMI -DADS MIAMI-DADE COUNTY PRODUCT CONTROL. SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES MR) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidode eovIeconomv GAF 1361 Alps Road Wayne, NJ 07470 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION:: GAF RuberoieModified Bitumen Roof System for Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 09-0224.01 and consists of pages 1 through 29. The submitted documentation was reviewed by Jorge L. Acebo. UTI—S-6 1 APPROVED NOA No.: I3.0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Pagel of 29 ROOFING SYSTEM APPROVAL Catesory Roofing Sub-Cateaorv: Modified Bitumen Material: APP/SBS Deck Tune• Wood Maximum Design Pressure: -75 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product _Dimensions Sneciflcation Description Matrix 102 SBS 5 gallons ASTM D30I9 Fiber reinforced rubberized cold -applied Membrane Adhesive adhesive for modified bitumen roof GAFGLAS® #75 39.37" ASTM D4601 systems. Type II asphalt impregnated and coated Base Sheet (I meter) Wide glass mat base sheet. GAFGLASO #80 Ultima 39.37' ASTMZ4601 Type II asphalt impregnated and coated, Base Sheet (I meter) Wide fiberglass base sheet. GAFGLAS'D FlexPly'" 6 39.37' ASTM D2178 Type VI asphalt impregnated glass felt GAFGLASO Ply 4 (t meter) Wide 39.37" ASTM 132178 with asphalt coating. Type IV asphalt impregnated glass felt GAFGLASOMineral (1 meter) Wide 39.37' ASTM D3909 with asphalt coating. Asphalt coated, glass fiber mat cap sheet Surfaced Cap Sheet (1 meter) Wide surfaced with mineral granules. GAFGLASO EnergyCap'� 39.37' ASTM D3909 Asphalt coated, glass fiber mat cap sheet BUR Mineral Surface Cap (1 meter) Wide surfaced with mineral granules with Sheet factory applied EnergyCote7 GAFGLASO Stratavento 39.37' ASTM D4897 Fiberglass base sheet coated on both sides Eliminator's Perforated (I meter) Wide with asphalt. Surfaced on the bottom side Venting Base Sheet with mineral granules embedded in asphaltic coating with factory GAFGLASO Stratavene 39.37' ASTM D4897 perforations. A nailable, fiberglass base sheet coated on Eliminator Perforated (1 meter) Wide both sides with asphalt. Surfaced on the Nailable Venting Base bottom side with mineral granules Sheet Ruberoid' SBS embedded in asphaltic coating. Heat -Weld` Smooth 39.37' ASTM D6164 Non -woven polyester mat coated with (1 meter) Wide polymer -modified asphalt and smooth Ruberoid® SBS Heat-Wele 39.37' ASTM D6164 surfaced. Non -woven polyester mat coated with Granule (1 meter) Wide polymer -modified asphalt and surfaced RoofMatch's 107 sq. ft. ASTM D6164 with mineral granules. Non -woven polyester mat coated with SBS Modified Granular (9.9 m2) SBS polymer -modified asphalt and Ruberoie SBS 39.37" ASTM D6164 surfaced with colored mineral granules. Non -woven polyester mat coated with fire Heat -Weld? 170 FR (I meter) Wide retardant polymer -modified asphalt and surfaced with mineral granules. NOA No.: 13-0424.14 MIAMPDADECOUN EQZI' Expiration Date: 11/06114 Approval Date: 10/31/13 Page 2 of 29 Test Product Product d� DDIit erasions Snecification Description Ruberoid SBS Heat-Wele 39.37' ASTM D6164 Non-woven polyester mat coated with Plus (1 meter) Wide polymer-modified asphalt and surfaced Ruberoid® SBS 39.37' ASTM D6164 with mineral granules. Non-woven polyester mat coated with fire Heat Weld'- Plus FR (I meter) Wide retardant polymer-modified asphalt and Ruberoid EnergyCap' 39.37' ASTM D6164 surfaced with mineral granules. Non-woven polyester mat coated with fire SBS Heat-Weld"" Plus FR (1 meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules and with Ruberoid® SBS 39.37' ASTM D6163 factory applied EnergyCote. Non-woven polyester mat coated with Heat-Weld` 25 (1 meter) Wide polymer-modified asphalt and smooth Ruberoid® Mop Granule 39.37' ASTM D6164 surfaced. Non-woven polyester mat coated with (I meter) Wide polymer-modified asphalt and surfaced Ruberoid® Mop Smooth 39.37' ASTM D6164 with mineral granules. Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and smooth Ruberoid® Mop Plus 39.37' ASTM 136164 surfaced. Non-woven polyester mat coated with (1 meter) Wide polymer-modified asphalt and surfaced Ruberoid Mop 170FR 39.37' ASTM D6164 with mineral granules. Non-woven polyester mat coated with fire (I meter) Wide retardant polymer modified asphalt and Ruberoid® Mop FR 39.37' ASTM D6164 surfaced with mineral granules. Non-woven polyester mat coated with fire (I meter) Wide retardant polymer-modified asphalt and surfaced with mineral granules. Ruberoid' Torch Smooth 39.37' ASTM D6222 Non-woven polyester mat coated with (I meter) Wide APP modified asphalt and smooth Ruberoid Torch Granule 39.37' ASTM D6222 surfaced. Non-woven polyester mat coated with (1 meter) Wide APP modified asphalt and Ruberoid® EnergyCap' 39.37' ASTM D6222 surfaced with mineral granules APP modified cap membrane with a torch Torch Granule FR (1 meter) Wide grade bottom surface and a mineral granular top surface coated with factory applied EnergyCote'm. RuberoldEnergyCap" 39.37" ASTM D6222 APP modified cap membrane with a torch Torch Granule Plus FR (1 meter) Wide grade bottom surface and a mineral granular top surface coated with factory RoofMatchT" 107 sq. ft. ASTM D6222 applied EnergyCote°". Non-woven polyester mat coated with APP Modified Granular (9.9 m2) APP polymer-modified asphalt and Ruberoid® Torch FR I meter ASTM D6222 surfaced with colored mineral granules. Non-woven polyester mat, coated with fire (39.37') Wide retardant asphalt modified bitumen membrane with granule surface. NQA No.: 13-0424.14 MIAMl EcoK)N� Expiratlon Date: 11/06/14 , Approval Date: 10/31/13 Page 3 of 29 Product Ruberoid® 20 Ruberold630 Ruberoid 30 FR Ruberoid® EnergyCap' 30 FR SBS Membrane Ruberoid Dual FR Topcoat® Elastomeric Roofing Membrane Topcoat® MB Pius Topcoat® Surface Seal SB FireOut' Fire Barrier Coating VersaShiele Fire -Resistant Roof Deck Protection APPROVED 39.37" (1 meter) ASTM D6162 Wide 1, 5 or 55 gallons ASTM D6083 5 or 55 gallons Proprietary 5 gallons ASTM D6083 5, 55 gallons Proprietary 42" x 100' rolls ASTM D226 Product Description SBS modified asphalt base sheet reinforce with a glass fiber mat. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant, polymer -modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant, polymer -modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. An acrylic, water based elastomeric membrane system designed to protect various types of roofing surfaces. Water based, low VOC primer used to block asphalt bleed -through. Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. Low VOC, water-based fire barrier coating. Non -Asphaltic, fire resistant fiberglass - based underlayment. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 4 of 29 Test Dimensions Specification I meter ASTM D6163 (39.37") Wide I meter ASTM D6163 (39.37' Wide 1 meter ASTM D6163 (39.37") Wide I meter ASTM D6163 (39.37") Wide 39.37" (1 meter) ASTM D6162 Wide 1, 5 or 55 gallons ASTM D6083 5 or 55 gallons Proprietary 5 gallons ASTM D6083 5, 55 gallons Proprietary 42" x 100' rolls ASTM D226 Product Description SBS modified asphalt base sheet reinforce with a glass fiber mat. Non -woven fiberglass mat coated with polymer modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant, polymer -modified asphalt and surfaced with mineral granules. Non -woven fiberglass mat coated with fire retardant, polymer -modified asphalt and surfaced with mineral granules and with factory applied EnergyCote. Non -woven polyester and fiberglass mat coated with file retardant, polymer - modified asphalt and surfaced with mineral granules. An acrylic, water based elastomeric membrane system designed to protect various types of roofing surfaces. Water based, low VOC primer used to block asphalt bleed -through. Solvent based sprayable thermoplastic rubber sealant designed to protect and restore aged roof surfaces and to increase a roofs reflectivity. Low VOC, water-based fire barrier coating. Non -Asphaltic, fire resistant fiberglass - based underlayment. NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 4 of 29 APPROVED INSULATIONS: Product Name EnergyGuarC Polyiso Insulation EnergyGuarC RA Polyiso Insulation EnergyGuarr RN Polyiso Insulation EnergyGuarr Perlite Recover Board EneruGuard•" Perlite Roof Insulation EnergyGuarr RA Composite Polyiso Insulation Manufacturer Structodeke High Density Fiber Board SecurocO Gypsum -Fiber Roof Board Table 2 Product Description Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Perlite recover board Perlite roof board Polyisocyanurate/wood fiberboard or perlite composite High density wood fiber Gypsum board Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF Blue Ridge FiberBoard, Inc. United States Gypsum Corp. APPROVED ]FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. TM Drill -Teo #12 Fastener Carbon steel fastener used Various GAF in steel or wood decks. 2. Drill-Tec'*m #14 Fastener Carbon steel fastener used Various GAF in steel, wood or concrete decks. 3. Drill-TecT" XHD Fastener Carbon steel extra heavy Various GAF duty fastener used in steel decks. 4. Drill-TecT" AccuTraco lat AZ -SS aluminized steel 3" x 3" GAF Plate plate for use with Drill- Tec#12 Fastener, Drill- TeeT" #14 Fastener and Drill-TecTM 415 Fastener. 5. Drill-TecT" ASAP 3S Drill-Tec7m #12 fastener Various GAF with Drill-TecT" 3" Standard Steel Plate. 6. Drill -Tec" AccuTraco Galvalume Steel plate for 3" x 3" GAF Recessed Plate use with Drill -TW' fasteners. 7. Drill -Tec.- 3" Steel Plate Round galvalume steel 3" GAF stress plate for use with Drill -Tee •" fasteners. 8. Drill -Tec•" 3" Standard Round galvalume plated 3" GAF Steel Plate steel stress plate with reinforced ribs for use with Drill -Tec"" fasteners. M SDApE 1111 6 T • NOA No.: 13-0424.14 Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 5 of 29 EVIDENCE SUBMITTED: Test Agen Test Identifier Description Pate Factory Mutual Research Corp. 3029832 FMRC 4470 05/11/07 3010215 FMRC 4470 03/01/01 3001276 FMRC 4470 01/28/99 1 B9A8.AM FMRC 4470 09/04/97 3D4Q2.AM FMRC 4470 04/30/97 OD1A8.AM FMRC 4470 04/01/98 Underwriters Laboratories R1306 UL 790 07/22/13 Trinity Engineering 4483.04 97-1 TAS 114 06/06/97 PRI Asphalt Technologies, Inc. GAF -020-02-01 ASTM D249 02101/02 ASTM D4977 GAF 306-02-01 ASTM E96 07/07/11 GAF 315-02-01 ASTM D2178 8/23111 GAF 314-02-01 ASTM D2178 8123/11 IRT-ARCON Inc. 02-005 TAS 114 03/01/02 02-014 TAS 114 04/08/02 01-039 TAS 114 03/01/02 Trinity ERD 06850.08.08 ASTM D6164 08/29/08 G6850.08.08 ASTM D6163 08/01/08 06850.10.08 ASTM D6222 10/06/08 06850.11.08 ASTM D6222 11/05/08 040620.07.12-2 ASTM D6222 07/17/12 G34140.04.11-2 ASTM D6163 04/25/11 G31360.03.10 ASTM D6164 03/31/10 G34140.04.114 ASTM D4601 04/25/11 G34140.04.11-5 ASTM D4897 04/25/11 G33470.01.11 ASTM D6164 01/13/11 G6850.08.07-1 ASTM D3909 08/13/07 030250.02.10-3-R1 ASTM D3909 11/26/12 PRI Construction Technologies LLC. ASTM D2178 GAF -314-02-01 08/23/11 ASTM D2178 GAF -315-02-01 08/23/11 ASTM D6083 GAF -245-02-01 06/10110 ASTM D6083 GAF -084-02-01 07/08/05 ASTM D6083 GAF -245-02-01 06/10/10 ASTM D6083 GAF -084-02-01 07/08/05 Momentum Technologies, Inc. ASTM D6162 AX04C9A 06/05/09 NOA No.: 13.0424.14 +�oecounrnr Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 6 of 29 Membrane Type: SBS/SBS Cold Applied Deck Type 1: Wood, Non -insulated Deck Description: 19/3Z" or greater plywood or wood plank decks System Type E(1): Base sheet mechanically fastened to roof deck. All General and System Limitations shall apply. Fire Barrier: FireOut'm Fire Barrier Coating, VersaShieldo Fire -Resistant Roof Deck (optional) Protection or Securock' Gypsum -Fiber Roof Board. Base sheet: GAFGLAS`° #80 Ultima'" Base Sheet, GAFGLAS Stratavene Eliminator Nailable Venting Base Sheet, Ruberoid® 20, Ruberoldo SBS Heat -Weld" Smooth or Ruberoid SBS Heat -Weld" 25 base sheet mechanically fastened to deck as described below: Fastening GAFGLAS® Ply 4, GAFGLAS F1exPly"' 6, GAFGLAS® #75 Base Sheet or any Options: of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. (Maximum Design Pressure --45 psf, See General Limitation #7) GAFGLAS' Ply 4, GAFGLAS® FlexPly"m 6, GAFGLASO #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec'" 412 Fastener, Drill-TecT" #14 Fastener or Drill -Tec'" XHD Fastener and Drill -Tec 3" Steel Plate, Drill - Tee ," AccuTraeP Flat Plate or Drill -Tec'.. AceuTraco Recessed Plate installed 12" o.c. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —4S psf, See General Limitation #7) GAFGLAS® FlexPlyTM 6, GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener sj5kcing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —52.5 psf, See General Limitation #7) GAFGLAS #80 Ultima"m Base Sheet, Ruberoid20, RuberoidoMop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. (Maximum Design Pressure —60 psf, See General Limitation #7) GAFGLAS® #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec #12 Fastener, Drill -Tec"' 414 Fastener or Drill -Tec XHD Fastener and Drill -Tec'" 3" Steel Plate, Drill -Tec." AccuTrace Flat Plate or Drill -Tec'" AccuTrae® Recessed Plate installed 12" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —60 psf, See General Limitation #7) Any of above base sheets attached to deck approved annular ring shank nails and 3" inverted Drill -Tec"' insulation plates at a fastener spacing of 9" o.c. at the 4" lap staggered in two rows 9" in the field. (Maximum Design. Pressure —60 psf, See General Limitation #7) NOA No.: 13-0424.14 MIAMI4QpECOUNTY Expiration Date: 11/06/14 i g "w ' Approval Date: 10/31/13 Page 25 of 29 GAFGLASO #75 Base Sheet or any of above base sheets attached to deck with Drill -Tec #12 Fastener, Drill -Tec #14 Fastener or Drill -Tec'* XHD Fastener and Drill -Tec`" 3" Steel Plate, Drill-Tec"m AccuTraceT Flat Plate or Drill -Tec"` AccuTraco Recessed Plate installed 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf, See General Limitation #7) Ply Sheet: (Optional) One or more plies GAFGLAS Ply 4, GAFGLAS® FlexPly'" 6, GAFGLAS' 480 Ultima Base Sheet, Ruberoide Mop Smooth or Ruberoide' 20 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Membrane: One or more plies of Ruberoid' Mop Smooth, Ruberoid® Mop 170 FR, Ruberoide' Mop Granule, RoofMatch`" SBS Modified Granular, Ruberoid® Mop Plus Granule, Ruberoid®20, Ruberoie30, RuberoideEnergyCap' 30 FR SBS Membrane, Ruberoid 30 FR or Ruberoid® Mop FR in adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Or One or more plies of Ruberoid Mop Smooth, Ruberoid® Mop Granule, RooWatchr" SBS Modified Granular, Ruberoid' Mop 170 FR, Ruberoid Mop Plus Granule, Ruberoid020, Ruberoido 30, RuberoidEnergyCap"30 FR SBS Membrane, Ruberoid® 30 FR or Ruberoid Mop FR adhered in MatrixTN 102 SBS Membrane Adhesive at an application rate of 1-2 ga]Jsq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1 Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 6//2. GAFGLAS`a Mineral Surfaced Cap Sheet or GAFGLAS EnergyCapBUR Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq. 3. Topcoat Elastomeric Roofing Membrane, Topcoat MB Plus (to be used as a primer with Topcoat® Elastomeric Roofing Membrane) or Topcoat® Surface Seal SB applied at I to 1.5 gal./sq. Maximum Design Pressure: See Fastening above NOA No.: 13-0424.14 FntwE ouN' Expiration Date: 11/06/14 Approval Date: 10/31/13 Page 26 of 29 WOOD DECK SYSTEM LIMITATIONS: I A slip sheet is required with GAFGLASO Ply 4 and GAFOLAS® FlexPly Tm 6 when used as a mechanically fastened base or anchor sheet. 2. Minimum '/" DensDecV Roof Board or Y2" Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LIMTTATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 IV., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchortbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-0424.14 r+tatyt•DApE CO Expiration Date: 11/06/14 t r Approval Date: 1051/13 Page 29 of 29 TGFU.Rl306 - Roofing Systems TGFU.R1306 Roofing Systems Page Bott,0 Roofing Systems See General Information for Roofing ,5ystems BUILDING MATERIALS CORP OF AMERICA, DBA GAF 1361 ALPS RD WAYNE, NJ 07470 USA Page I of 2 R1306 "Ruberold@ 20" or "Ruberoid@ 20 HT' or "Ruberold@ Modified Base Sheet" may be utilized as an alternate to Type G2 base sheets In any of the following Classifications. 1/2 -in. thick (minimum) gypsum board or 1/4 -in. thick (minimum) Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuardT" Roofboard" may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 -in. thick minimum) roof decks. However, the butt joints in the gypsum board and Georgia-Pacific Gypsum LLC "DensDeck@ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard'" Roofboard" are to offset a minimum of 6 -In. with the butt joints in the roof deck. If polystyrene Is part of the roof system, It must be placed below the overlayment board. Multiple plies of "GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "Trl-Ply® Ply 6" may be adhered to Georgia-Pacific Gypsum LLC "DensDeck @ Roofboard," "DensDeck Prime@ Roofboard" or "DensDeck DuraGuard" Roofboard" in hot roofing asphalt. "EnergyGuardTM Ultra" is an acceptable alternate to "EnergyGuardTM RF" in any applicable Classification. "GAF Stratavents Eliminator'" Venting Base Sheet (Nailable)" may be mechanically attached or hot mopped over noncombustible decks and as a recover over existing roof systems. "GAFGLAS@ Perlite Insulation" may be utilized as a cover board over "EnergyGuard" RF" Insulation in any of the following systems. Unless otherwise indicated, the roof insulation is mechanically fastened, adhered with hot mopping asphalt or UL Classified urethane Insulation adhesive. Polystyrene referenced in any of the following Classifications Include "EnergyGuardT" EPS Insulation". Unless otherwise Indicated, all Insulations may be adhered with any UL Classified Insulation Adhesive per the manufacturer's installation instructions (excluding LRF Adhesive 0) in any applicable Non -Combustible Roof Deck Classifications. References to glass fiber insulation include "EnergyGuard Fiberglass Insulation". "EnergyGuardi00 Tapered" is an acceptable alternate to "EnergyGuardTM" in any applicable Classification. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Type G2 asphalt glass mat base sheet ("GAFGLASO 975 Base Sheet" or "Tri -Ply® #75 Base Sheer", or "GAFGLASO #80 ULTIMA") is a suitable alternate for Type Gi asphalt glass fiber ply sheet ("GAFGLASO Ply 4" or "Tri -Ply@ Ply 4", or "GAFGLASO Ply 6") in the Class A, B or C roof systems indicated below. The roof deck may first be covered with one ply Type G2 asphalt saturated glass mat base sheet "GAF Stratavent@ Eliminator'"" Venting Base Sheet (Perforated)" or "GAF Stratavent@ EliminatorTM Venting Base Sheet (Nailable)." Perforated base sheets to be loose laid or fully adhered with hot roofing asphalt and nailable base sheets are to be mechanically attached granule side down. As an option Type G2 asphalt glass mat base sheet ("GAFGLASO #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or "GAFGLAS@ #80 ULTIMA" or "GAF Stratavent@ Eliminator'" Venting Base Sheet (Nallable)" may be substituted for Type GI asphalt glass fiber ply sheet ("GAFGLAS@ Ply 4" or "Tri -Ply® Ply 4" or "GAFGLASO Ply 6") as the nailed base ply in the following systems. Bottom ply or base sheet may be solid mopped, Spot mopped or mechanically fastened. Unless otherwise indicated, all Insulations may be hot mopped or mechanically fastened. "GAFGLASO Flashing" or "Ruberold@" may be used for flashing in any of the Class A, B or C systems listed below. When "perlite" is referenced, this includes "GAFTEMP PERMALITE@" or any other UL Classified perlite Insulation, Crushed stone or slag are suitable alternates for gravel in any of the Class A, B or C systems listed. http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name-TGFU.RI306&ccnshoit... 3/7/2014 TGFU.RI306 - Roofing Systems Page 2 of 2 Structural cement fiber building units are considered suitable to be included as a deck In the following Class A, B or C systems listed over C-15/32 or NC. The use of gypsum board under any of the following Class A, B or C systems does not adversely affect the rating. The use of 1/2 -in. minimum thick gypsum board Is an acceptable alternate for minimum insulation over C-15/32 thick roof decks. The use of polystyrene insulation board between minimum 3/4 -in. thick perlite board and deck with rosin paper (periite/rosin paper/polystyrene/perlite) is a suitable alternate for polyisocyanurate board in the following Class A, B or C systems. "EnergyGuardT01 RA" or "Tapered EnergyGuard* RA" or "EnergyGuard' Composite RA" may be substituted for any Atlas Roofing Corp. polyisocyanurate insulation in any of the following Classifications. Trumbull "Perms Mop" may be utilized with any of the following "Asphalt Felt Systems with Hot Roofing Asphalt". "GAFGLAS@ #80 Premium Base Sheet" may be used In any of the following systems. "GAFGLAS® Flex Ply 6" and "Tri -Ply(+ Ultra -Flexible Ply 6" are suitable alternates to "GAFGLAS@ Ply 6". "GAFTEMP Permalite Recover Board" may be used In lieu of any perlite Insulation in any of the following NC Classifications. Unless otherwise Indicated, any of the "Asphalt Felt Systems with Hot Roofing Asphalt" may be surfaced with "TOPCOAT% Fireshleld MB" at 21/2 to 3-gal/100-R2. "Ruberoid@ Dual Smooth" may be used as an alternate to "Ruberoid@ Mop Smooth" or "Ruberold@ 20" or "Ruberoid@ 20 HT" "Ruberoid® Mop Smooth 1.5" may be used as an alternate to "Ruberold@ Mop Smooth" Class A, B and C Hot roofing asphalt, for use with organic and glass felts or modified bitumen membranes. "Ruberoid@ Heat Weld" SBS roofing membrane may be used In lieu of "Ruberoid® Mop" SBS products in any applicable Classification, Class A 1. Decic C-15/32 Incline: 3 Insulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polyisocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply : — Three or more plies Type GI or "GAFGLAS% Ply 4" or "Tri -Ply% Ply 4" or "GAFGLAS% Ply 6" hot mopped. rfacing: — Gravel. C-15132 Incline: 2 dnsulation (Optional): — One or more layers perlite or wood fiber or glass fiber or polyisocyanurate or urethane or perlite/polylsocyanurate composite or perlite/urethane composite or wood fiber/polyisocyanurate composite or phenolic, any thickness. Ply Sheet: — Three or more plies Type GI or "GAFGLAS% Ply 4" or "Tri -Ply% Ply 4" or "GAFGLAS% Ply 6". Cap Sheet: — One ply Type G3 "GAFGLAS(D Mineral Surfaced Cap Sheet" or "Tri -Ply@ Mineral Surfaced Cap Sheet " or "GAFGLAS(ID EnergyCap"° SUR Mineral Surfaced Cap Sheet," http://database.ul.com/cgi-binIXYVItemplatelLISEXT/1 FRAMElshowpage.html?name=TGFU.RI306&ccnshort... 3/7/2014