Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PL-14-1523
Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-215970 Permit Number: PL -7-14-1523 Scheduled Inspection Date: September 30, 2014 Inspector: Diaz, Osvaldo Owner: GRABLE, JANE Job Address: 1700 NE 105 Street 117 Miami Shores, FL Project: <NONE> Contractor: JAMES DENTICO CONTRACTING INC Building Department Comments NEW TANK LESS WATER HEATER N-85 REPLACING EXISTING 30 GAL LOWBOY IN KITCHEN. AS WELL KITCHEN REMODEL FOR PLUMBING Permit Type: Plumbing - Residential Inspection Type: Final Work Classification: Addition/Alteration Phone Number Parcel Number 1122300500170 INSPECTOR COMMENTS False Phone: 305-756-6553 September 29, 2014 For Inspections please call: (305)762-4949 Page 4 of 31 Inspector Comments Passed O t Failed Correction Needed ❑ Re -Inspection ❑ Fee No Additional Inspections can be scheduled until re -inspection fee is paid. September 29, 2014 For Inspections please call: (305)762-4949 Page 4 of 31 Miami Shores Village TV Building Department JUL 16 2014 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 BY: Tel: (305) 795-2204 Fax: (305) 756-8972 INSPECTION LINE PHONE NUMBER: (305) 762-4949 BUILDING PERMIT APPLICATION ❑BUILDING ❑ ELECTRIC ❑ ROOFING (FBC 20 JO f ,. Master Permit No. @�(� - ` _[4- " Sub Permit No. ❑ REVISION ❑ EXTENSION ❑RENEWAL PLUMBING ❑ MECHANICAL ❑PUBLIC WORKS ❑ CHANGE OF ❑ CANCELLATION ❑ SHOP 11 e�� /��- �s CONTRACTOR l �f DRAWINGS JOB ADDRESS: 1 ! 00 M V7 J�� U 4 1 City: Miami Shores County: Miami Dade Zip: 3 Folio/Parcel#: Is the Building Historically Designated: Yes NO Occupancy Type: Load: Construction Type: Flood Zone: BFE: FFE: OWNER: Name (Fee Simple Addre City: _ Tenant/Lessee Name: Phone#: Email: CONTRACTOR: Company Name: Address: city: 1111 t Qualifier Name: State Certification or Registration #: C EC6 12 ® li Certificate of Competency #: DESIGNER: Architect/Engineer: Phone#: Zip: 3 3( 39 CS --E- �LS-S-3 Address City: State Zip: Value of Work for this Permit: $' co Square/Linear Footage of Work: Type of Work: ❑ Addition ❑ Alteration ❑ New Repair/Replace ❑ Demolition Specify color of color thru We.- Submittal ile: Submittal Fee $ Permit Fee $ CCF $ CO/CC $ Scanning Fee $ Radon Fee $ DBPR $ Technology Fee Structural Reviews $ (Revised02/24/2014) Training/Education Fee $ Notary $ Double Fee $ Bond $ TOTAL FEE NOW DUE $ .N Bonding Company's Name (if applicable) Bonding Company's Address City State Mortgage Lender's Name (if applicable) Mortgage Lender's Address City State Zip Zip Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRIC, PLUMBING, SIGNS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:' Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certfed copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will not be approved and a reinspection fee will be charged. Signature Signature___. t/ OWNER or AGENT `� CONTRACTOR The foregoing instrument was acknowledged before me this I day of -Sf-�� 1- .20 by 07�43 LA- who is personally known to me or who has produced _ _ C— ) as identification and who did take an oath. NOTARY PUBLIC: Sign Prim The foregoing instrument was acknowledged before me this day of N ---\l 20by —3;F-,V-\eis'e- ol® . who is person lly known me or who has produced as identification and who did take an oath. NOTARY PUBLIC: SON ROBERTSON T0V:CiSEN0 Sign: �, Public - State of Print: : • = My comm. Expires Aug Florida3, 2015 793 Seal s �,' .Vommission # ;/�FOFf���`,, Bonded Through National Notary Assn. ;��� .EE173059, Q, Seal: 88888888888888$888888888888888888888888888888888888888888888888888888888888888888888888888888888888888888888 APPROVED BY Plans Examiner Zoning Structural Review (Revised02/24/2014) Clerk Miami shores Village Building Department 10050 N.E.2nd Avenue Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 Notice to Owner — Workers' Compensation Insurance Exempf16rr,, Florida Law requires Workers' Compensation insurance coverage under Chapter 440 of the Florida Statutes. Fla. Stat. § 440.05 allows corporate officers in the construction industry to exempt themselves from this requirement for any construction project prior to obtaining a building permit. Pursuant to the Florida Division of Workers' Compensation Employer Facts Brochure: An employer in the construction industry who employs one or more part-time or full-time employees, including the owner, must obtain workers' compensation coverage. Corporate officers or members of a limited liability company (LLC) in the construction industry may elect to be exempt if - 1 . f: 1. The officer owns at least 10 percent of the stock of the corporation, or in the case of an LLC, a statement attesting to the minimum 10 percent ownership; 2. The officer is listed as an officer of the corporation in the records of the Florida Department of State, Division of Corporations; and 3. The corporation is registered and listed as active with the Florida Department of State, Division of Corporations. No more than three corporate officers per corporation or limited liability company members are allowed to be exempt. Construction exemptions are valid for a period of two years or until a voluntary revocation is filed or the exemption is revoked by the Division. Your contractor is requesting a permit under this workers' compensation exemption. In these circumstances, Miami Shores Village does not require verification of workers' compensation insurance coverage from the contractor's company. Therefore, you may be personally liable for the worker compensation injuries of any person allowed to work under this permit. Please check with your insurance carrier since most property insurance policies DO NOT cover this type of liability. BY SIGNING BELOW YOU ACKNOWLEDGE THAT YOU HAVE READ THIS NOTICE AND UNDERSTAND ITS CONTENTS. Owner f PrintNam �i�ry L C� >� l.(_ Signature: r� State of Florida ) County of Miami -Dade ) 9 Sworn to ajid subscribed before me this day of By (SEAL) Tvt)e of Identification Contractor Print State of Florida ) County of Miami -Dade ) Sworn to and subs day of Lo of Identification �G Y�SOoffj OBE =N TOWNSEND Public - State of Florida My Comm. Expires Aug 3, 2015 COmmissinn # FF 106793 Bonded Through National Notary Assn. 05-08-2014 JEFF ATWATER STATE OF FLORIDA CHIEF FINANCIAL OFFICER DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION * * CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW * * CONSTRUCTION INDUSTRY EXEMPTION This certifies that the individual listed below has elected to be exempt from Florida Workers' Compensation law. EFFECTIVE DATE: PERSON: FEIN: 05/03/2014 EXPIRATION DATE: 05/02/2016 DENTICO JAMES L 592246282 BUSINESS NAME AND ADDRESS: JAMES L DENTICO CONTRACTING INC 10055 BISCAYNE BOULEVARD MIAMI SHORES FL 33138 SCOPES OF BUSINESS OR TRADE: 1- HEATING, VENTILATION, AIR-COND 3- LICENSED PLUMBING CONTRACTOR 2- LICENSED ELECTRICAL CONTRACTOR 4- LICENSED GENERAL CONTRACTOR B IMPORTANT: Pursuant to Chapter 440 . 05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election under this section may not recover benefits or compensation under this chapter. Pursuant to Chapter 440.05112), F.S., Certificates of election to be exempt... apply only within the scope of the business or trade listed on the notice of election to be exempt. Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of Ibis section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01-11 QUESTIONS? (850) 413-160E PLEASE CUT OUT THE CARD BELOW AND RETAIN�FOR FUTURE REFERENCE STATE OF FLORIDA DEPARTMENT OF FINANCIAL SERVICES DIVISION OF WORKERS' COMPENSATION CONSTRUCTION INDUSTRY CERTIFICATE OF ELECTION TO BE EXEMPT FROM FLORIDA WORKERS' COMPENSATION LAW 9 EFFECTIVE: 05/03/2014 EXPIRATION DATE: 05/02/2018 PERSON: JAMES L DENTICO FEIN: 592246282 BUSINESS NAME AND ADDRESS: JAMES L DENTICO CONTRACTING INC 10055 BISCAYNE BOULEVARD MIAMI SHORES, FL 33138 SCOPE OF BUSINESS OR TRADE: 1- HEATING, VENTILATION, AIR-COND 2- LICENSED ELECTRICAL CONTRACTOR 3- LICENSED PLUMBING CONTRACTOR 4- LICENSED GENERAL CONTRACTOR IMPORTANT 0 Pursuant to Chapter 440.05(14), F.S., an officer of a corporation who elects exemption from this chapter by filing a certificate of election L under this section may not recover benefits or compensation under this D chapter. Pursuant to Chapter 440.05(12), F.S., Certificates of election to be H exempt.. apply only within the scope of the business or trade listed on Rthe notice of election to be exempt j E Pursuant to Chapter 440.05(13), F.S., Notices of election to be exempt and certificates of election to be exempt shall be subject to revocation if, at any time after the filing of the notice or the issuance of the certificate, the person named on the notice or certificate no longer meets the requirements of this section for issuance of a certificate. The department shall revoke a certificate at any time for failure of the person named on the certificate to meet the requirements of this section. CUT HERE O.UESTIONS? (850) 413-1609 Carry bottom portion on the job, keep upper portion for your records. DWC-252 CERTIFICATE OF ELECTION TO BE EXEMPT REVISED 01-11 `; f Policy Number. Date Entered: A� ® CERTIFICATE OF LIABILITY INSURANCE THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFER NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER. IMPORTANT: If is certificate holler to an ADDITIONAL INSURED, the pollcy(ies) must be endorsed. If SUBROGATION IS WANED, subject to the terms and conditions of the policy, certain policies may require an endorsement A moment on this certificate does not confer rights to the eertl8cate holder in lieu of such endomement(s). PRODUCER C RAMS SATdJSR ]ITSDRAlIt3r 730 SW 4TH ST. 93 CAPE CORAL, FL 33991 PANE (866)587-7147 FAX Na.(868)542-3507 ED ALLI80N8SALbOM TSDRB.COM Di9URER(8) AFFORDING COVERAGE NAILS COMMERCIAL GENERAL LIABILITY CLAMIS41ADE ® OCCUR INSURER A: PRENWIRBD CONTRACTORS INS. CO. (RRG) 12497 INSURED JAMES L. DENTICO CaIfTPACTING IIITC INSURER e: INSURER C: JAMES DBRTICO 10055 SISCAYNB BLVD. MIAMI SHORES, FL 33138 INSURER D: INSURER E: INSURER F BENI. AGGREGATE LOST APPLIES PER: POLICY D ECT F-1 LOC OTHER: eHT1FIr�TF al THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE WSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LTGTYPE OF INSURANCE ADUL '"MRPOLBCl/ NurBER POLICY EFF POLICY EXP ITYM LIMITS A COMMERCIAL GENERAL LIABILITY CLAMIS41ADE ® OCCUR PCICS026-PM70585 —04 0/28/2019 /28/2014 EACH OCCURRENCE $ 1,000,000 PREMISESwA oamra $ 5O 000 NED EXP (Anyom percal) S O PERSONAL&ADV INJURY $1.000.000 BENI. AGGREGATE LOST APPLIES PER: POLICY D ECT F-1 LOC OTHER: GENERAL AGGREGATE $ PRODUCTS-COMPAIP AGO $ 1,000,000 $ AUTOMOBILE LIABILITY ANY AUTO ALL OWNED S AUTOS AUTOSU�D HIRED AUTOS NON -OWNED COMBINED LIhR $ (Ea amNenl BODILY INJURY (P. P—) S BODILY INMRY (Per =Werd) $ P_..DAMAGE $ a UMBRELLA UMBRE LugNB L OCCUR CLA0I3-MADE I EACH OCCURRENCE S AGGREGATE $ DED I I RETENTIONS $ a fORUENSCOMPBRSATION ANDEMPLOYERS'LIABILITY YIN ANY PROPREETTORPARTNERREXECUTIVE OFFICEROAMBER EXCLUDED? OPil.�se, b, NN of DESCRIPTION OF OPERATIONS bob. NIA PE OTH- STATUTE ER EJ_ EACH ACCIDENT $ E.L. DISEASE- FA EMPLOYE $ El. DISEASE_LIMIT S DESCRIPTION OF OPERATIONS I LOCATIONS IVEHICLES (ACOIW101,AddMonal Ra ft Seaedola,maybeanaabad Oomreapamiaragolred) PLDM 3NG GEK I11 IGAIC HLILUEH CAMCCI l A"^w bffAmr SHORES VIISAGB SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 10050 19E 214D AVE ACCORDANCE WITH THE POLICY PROVISIONS. MIAIII SHORES, FL 33138 305 756 8972 AUTHOR® REPRESENTATIVE ©1688-2014 ACORD CORPORATION. All rights reserved. ACORD 25 (2014101) The ACORD name and logo are registered marls of ACORD Produced using Forms Boas Plus software. www.FormsEloss.00m; InWessWe Pubfishing 800.208-1977 I j L 16 2014 COUNTY MIAMI DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Sheet, Room 208 DEPARTi MW OF REGULATORY AND ECONOARC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.mlamldade.gov1eeonomr Niagara Industries, Inc. 2540 NW 3e Court Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Titan Tankless Water Heater APPROVAL DOCUMENT: Drawing titled "Titan Electronic Tankless Water Heater ", sheet 1 of 1, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSHE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and following statement: "Miami Dade County Product Control Approved" and required markings per national registered testing lab, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of theBuilding Mcial. This NOA renews NOA # 10.0107.01 and consists of this page I and evidence page E-1, as.well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrem, P.E. NOA No* 13-0911,11 Expiration Date: September 25, 2018 Approval Date: January 23, 2014 Page 1 Niagara Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS "Subinitted under NOA # 03-0919.02" 1. Drawing titled "Titan Electronic Tankless Water Heater", sheet 1 of 1, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E. B. TESTS "Subndtted under NOA # 10-0107.01" 1. Test report on Dielectric Voltage -Withstand and Grounding Continuity Test per UL - 499 of Tankless Hot Water Heater, Models N-10, 42, 64, 75, 85, 100,120, 160, 180 and 210, issued by MET Laboratories, Inc, Test Report No. 27956, dated 01 /05/2010, signed by Rick Cooper. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) 2. MET Laboratories, Inc, Quarterly Follow-up Reports. E. MATERIAL CERTIFICATIONS "Submitted under NOA # 10-0107.01" 1. Niagara Industries Factory Follow-up Inspection Report, issued by MET Laboratories, Inc, Track. # 28332, dated 01/04/2010, signed by R.M. Lutz. 2. Certification Report and Follow-up Service Procedure on Niagara Industries' Tankless Hot Water Heater, Models: NTf1b 10, 42, 64, 75, 85, 100, 120, 160, 180 and C-f/b 10, 42, 64, 75, 85,100 and 120, for L/N # 29580, issued by Applied Research Laboratories, dated 05/04/2009, signed by 3 different inspectors. 3. Certification Report # 29580, dated 01/29/1997 and revised 11/01/2007 and Quarterly Follow-up Summary Report, dated 07/16/2008, both issued by Applied Research Laboratories, signed by Luis Martinez. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC issued by Professional Advancement Corporation, dated 01/06/2014, signed and sealed by Manuel R. Cereijo, P.E. f'SubinNed under NOA # 10-0107.01" 2. Statement letter of standard compliance issued by Met Laboratories, Inc, dated 12/03/2009, signed by Rick Cooper. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 13-0919.07 Expiration Date: September 25, 2018 Approval Date: January 23, 2014 E -1 NIAGARA INDUSTRIES INC. TITAN TANKLESS WATER HEATER THE HEATER INCORPORATES A HEATING ELEMENT HOUSED WITH IN A HEATER EXCHANGER, AN ELECTRICAL COMPONENT MONITORS THE TEMPERATURE OF THE WATER HEATER AT - DIFFERENT FLOW RATES MAINTAINING A PRE SET TEMPERATURE ALLOWING THE USE OF CONVENTIONAL OR SINGLE HANDLE FAUCETS r MAX MOUS I MAX at 220 V AWS of 220 V 1.8 Kw 1 220 V I SA 7 � 220 V 6.4 KW 220 V I r Heat Chamber 2. Float Cavity I P.C. Board 4. Resistor S. Leh Side 6. Front 7. Switch S. water Out 9.1Yater In N.42 4.2 Kw 220V 19 'N -10 3.2 KW _'110V Z9 PM)WCT RBi sW =ComoDoOM�s�ibtlial+lp�ib� P,a�:rac,:„ rs it ;y e� ttt�t a,oe tow Not v-�vro ,vl �++e�+.e. t+a a ZYM aw=p I s� tury01lt10t �S`�i1 iagara Industries Inc.. A120 N.W. 28th Street Miami Fla.. 33142 [h. 305-876--9014 1. Fx. 305--876-9030 'T=1tan E2eCtt'anic Tankie4s3 Water FtegL,a" tew - M=L N-120 N. too MARJL 11�Ii PM30h 24244777 N - 65 9645 SW "St N • 95 tHtamf, F!. 33165 r MAX MOUS I MAX at 220 V AWS of 220 V 1.8 Kw 1 220 V I SA 7 � 220 V 6.4 KW 220 V I r Heat Chamber 2. Float Cavity I P.C. Board 4. Resistor S. Leh Side 6. Front 7. Switch S. water Out 9.1Yater In N.42 4.2 Kw 220V 19 'N -10 3.2 KW _'110V Z9 PM)WCT RBi sW =ComoDoOM�s�ibtlial+lp�ib� P,a�:rac,:„ rs it ;y e� ttt�t a,oe tow Not v-�vro ,vl �++e�+.e. t+a a ZYM aw=p I s� tury01lt10t �S`�i1 iagara Industries Inc.. A120 N.W. 28th Street Miami Fla.. 33142 [h. 305-876--9014 1. Fx. 305--876-9030 'T=1tan E2eCtt'anic Tankie4s3 Water FtegL,a" oLZ—/� Al 16 2014 iM"H DADS COUNW PRODUCT CONTROL SECTION 11805 SW 26 Street, Room= DEPARTIUMT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE {NOA) www.mlgMidadeegov/eeonomv Niagara Industries, Inc. 2540 NW 3e Court Miami, FL 33142 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) andlor the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Titan Tanldess Water Heater APPROVAL DOCUMENT: Drawing titled "Titan Electronic Tankless Water Heater ", sheet 1 of 1, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, modellseries and following statement: "Miami -Dade County Product Control Approved" and required markings per national registered testing lab, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the -Building Oficial. This NOA renews NOA # 10=0107.01 and consists of this page 1 and evidence page E-1, as.well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrem, P.E. NOA No. 13-0919.07 Expiration Date: September 25, 2018 Approval Date: January 23, 2014 tit E� �� Page 1 Niagara Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBAff D A. DRAWINGS "Submitted under NOA # 03-0919.02" 1. Drawing titled 'Titan Electronic Tankless Water Heater", sheet 1 of 1, prepared by Niagara Industries, Inc., signed and sealed by Manuel R. Cereijo, P.E. B. TESTS "Submitted under NOA #.10-0.107. 01 1. Test report on Dielectric Voltage -Withstand and Grounding Continuity Test per UL - 499 of Tankless Hot Water Heater, Models N-10, 42, 64, 75, 85,100,120,160,180 and 210, issued by MET Laboratories, Inc, Test Report No. 27956, dated 01 /05/2010, signed by Rick Cooper. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER) 2. MET Laboratories, Inc, Quarterly Follow-up Reports. E. MATERIAL CERTIFICATIONS "Submitted under NDA # 10-01#7 01" 1. Niagara Industries Factory Follow-up Inspection Report, issued by MET Laboratories, Inc, Track # 28332, dated 01/04/2010, signed by R.M. Lutz. 2. Certification Report and Follow-up Service Procedure on Niagara Industries' Tankless Hot Water Heater, Models: N-1) b 10, 42, 64, 75, 85, 100, 120, 160, 180 and C-fyb 10, 42, 64, 75, 85,100 and 120, for L/N # 29580, issued by Applied Research Laboratories, dated 05/04/2009, signed by 3 different inspectors. 3. Certification Report # 29580, dated 01/29/1997 and revised 11/01/2007 and Quarterly Follow-up Summary Report, dated 07/16/1008, both issued by Applied Research Laboratories, signed by Luis Martinez. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC issued by Professional Advancement Corporation, dated 01/06/2014, signed and sealed by Manuel R. Cereijo, P.E. "Submitted under NOA # 10-0107.01" 2. Statement letter of standard compliance issued by Met Laboratories, Inc, dated 12/03/2009, signed by Rick Cooper. Carlos M. Utrera, P.E. Product Control Examiner NOA No. 13-0919.07 Expiration Date: September 25, 2018 Approval Date: January 23, 2014 E -1 � � b NIAGARA INDUSTRIES INC. TITAN TANKLESS WATER HEATER THE HEATER INCORPORATES A HEATING ELEMENT HOUSED WITH IN A HEATER EXCHANGER,, AN ELECTRICAL COMPONENT MONITORS THE TEMPERATURE OF THE WATER HEATER AT. DIFFERENT FLOW RATES MAINTAINING A PRE SET TEMPERATURE ALLOWING THE USE OF CONVENTIONAL OR SINGLE HANDLE FAUCETS P4 ATMEL- 24477 9605 SW 198t ARMA FL 33165 1u10Dl L MAX KW cit 220 V VOLTS MAX AhWS a 220 V N-120 11.8 KW 220V 54 N. 100 10.8 KW 220V 49 N-85 &S KW 224 V 38 N-75 "KW 220V 34 N% 64 "KW 29 N.42 1_11220V--1 .4.2 KW 220 V 19 'N-10 3.2 KW 110V 1 29 �saoa�lytagwi�tiN1!todOs ����� i. Heat Chamber 2. Float Cavity 3. P.C. Board 4. Resistor S. Leh Side 3 6. Front 7. Switch S. Water Out 9. Water in BAww.. UMftl ` 6 C`! . t Q�IQ �i�1 2`� .. . -1 ' i..� i 9t 4ri C15 4� PAW god d Oh+L Niagara Industries Inc.' 9420 N.W. 28th Street Miami Pla. 33142 ?h. 305-876-•9010 I• Fx. 305-876-9x30 Titan E2eCtz'anic Tankles i Water nam aer.