RF-13-7397 Inspection Worksheet Miami Shores Village 10050 N.E. 2nd Avenue Miami Shores, FL Phone: (305)795-2204 Fax: (305)756-8972 Inspection Number: INSP-189616 Scheduled Inspection Date: April 22, 2013 Inspector. Bruhn, Norman Owner: , Job Address: 1260 NE 98 Street Miami Shores, FL 33138 - Project: <NONE> Permit Number: RF -4-13-739 Permit Type: Roof Inspection Type: Tin Cap Work Classification: Flat Phone Number Parcel Number 1132050090320 Contractor: SUPREME ROOFING & CONSTRUCTION INC Phone: (786)229-9331 Building Department Comments RE -ROOF FLAT Passed Failed Correction ❑ Needed Re -Inspection Fee No Additional Inspections can be scheduled until re -inspection fee is paid. TIN CAP SPACEING False INSPECTOR COMMENTS False Inspector Comments CREATED AS REINSPECTION FOR INSP-189130. Work covered without inspection. NB April 19, 2013 For Inspections please call: (305)762.4949 Page 28 of 38 a Charles C. Mitchell Professional Engineer license # 11127 924 North Highway, Hollywood Florida, FL 33025 (305) 336-5069 ROOF TIN CAP INSPECTION For: Supreme Roofing Service Property Location: 2600 N.W. 155 Terrace 1260 NX 98 Street, Miami Shores, Florida 33138 Miami Gardens, Florida 33054 INSPECTION AGREEMENT It is understood and agreed that this inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. The report is a compliance inspection certification to show that the roof is in accordance to governmental codes and regulations. VISUAL FLAT ROOF INSPECTION: Dear building official, On April 19, 2013 I performed a visual inspection at above address to determine if the tin caps and felt were in compliance with the Florida building code. The roof was plugged in various sections and during a visual inspection I observed the following. 1. 2 ply #75 base sheet nailed to 5/8" plywood sheeting. 2. 2 ply #75 base sheet nailed at perimeter edges are spaced @ 6" O.C. 3. The tin caps in the field are spaced @ 9" O.C. 4. The tin caps around the perimeter edges are spaced @ 6" O.C. 5. Top ply observed to be 1 -ply ruberoid HW 170 F/R HEAT WELD. The methodology used to repair the roof is in fact in accordance with the Florida Building Code 2010. Please do not hesitate to contact this firm if there are questions regarding this inspection. Charles C. Mitchell P.E. Miami Shores Village Building Department APR 11 .i13 10050 N.E.2nd Avenue, Miami Shores, Florida 33138 Tel: (305) 795.2204 Fax: (305) 756.8972 INSPECTION'S PHONE NUMBER: (305) 762.4949 FBC 20 LO BUILDING Permit No. PERMIT APPLICATION Master Permit No. Permit Type: BUILDING (:ROOFING JOB ADDRESS: IZ L d k,) ,E. "1 )4 - City. Miami Shores County: Miami Dade Zip: 3 3 J 3 Folio/Parcel#: —J-13 Is the Building Historically Designated: Yes NO ✓ Flood Zone: OWNER: Name (Fee Simple � ill /uaY. !'"/ City: &--c— -vin e" State: 11–L Zip: 131 LO Tenantll,essee Name: A) JA Phone#: 10114 Email: !y 44 CON Addn City: A,Qldu State: rL Zip: .7365Y Q eVAI� ',&, ,r Qualifier Name: � Phone#: State Certification or Registration #: # i3 r� Certificate of Competency #: Contact PhoneEmail Address: DESIGNER: Arcc tect/EnII ineer: Phone#: Value of Work for this Permit: $�� 8 o v Square/Linear Footage of Work: S t� m �J Type of Work: ❑Addition ❑AIVation ❑New epair/Replace ❑Demolition Description of Work: Scanning Fee $ Radon Fee $ DBPR $ Bond $ Notary $ Training/Education Fee $ Technology Fee $ Double Fee $ Structural Review $ TOTAL FEE NOW DUE $ Bonding Company's Name (if applicable) Bonding Company's Addres City Mortgage Lender's Name (i Mortgage Lender's Address City Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS and AIR CONDITIONERS, ETC..... OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." Notice to Applicant: As a condition to the issuance of a building permit with an estimated value exceeding $2500, the applicant must promise in good faith that a copy of the notice of commencement and construction lien law brochure will be delivered to the person whose property is subject to attachment. Also, a certified copy of the recorded notice of commencement must be posted at the job site for the first inspection which occurs seven (7) days after the building permit is issued. In the absence of such posted notice, the inspection will ,trot be gpprovved-"d�a reinspection fee will be charged Signature �- 'O or Agent The forego' instrument was a owl ore s D day of fttj,i�/ , 20 a b , who is personally known tom di 5 pr ce As identification and who did take an oath. NOTARY PUBLIC: Print.94- t i, p G v My Commission Expires: -r/ '2 I/ p ftft-owd- O� 9160fte Iown-!nu Signature L -2 Conor The foregoing instrument was ac owleJg4 bef4brd me this day o —,200, , who is personally known to me or who has produced as, i tifigation and who did take an oath. NOTARY PUBLIC: ' ._ %3 Structural Review Sl %/6` 6 Print: UXW-2 rn4 My Commission Expires: ��. 112- e (Revised 5=012)(Revised 3/12/2012) )(Revised 06/10{2009)(Revised 3/15/09)(Revised 7/10/2007) Clerk Property Information: Folio 11-3205-009-0320 2012 2011 Property Address 1260 NE 98 ST County Owner Name(s) HSL PROPERTY HOLDINGS II LLC $25,000/$295,832 $25,000/$286,488 Mailing Address 2600 ISLAND BLVD #2906 AVENTURA FL 33160 - Regional 7�700/$270,8321 Primary Zone 1400 SGL FAMILY - 3001-3250 SQ Use Code 0001 RESIDENTIAL -SINGLE FAMILY 7/2012 $349,300 Beds/Baths/Half 2/2/0 19800-2197 Sales which are qualified Floors 1 4/1981 1$100,0001 Living Units 1 Adj. Sq. Footage 2,119 Lot Size 10,900 SQ FT Year Built 1951 Legal Description EARLETON SHORES PB 43-80 LOT 5 & W25FT LOT 4 BLK 3 LOT SIZE IRREGULAR OR 19800-2197 07 2001 1 OR 28213-3762 071212 Assessment Information: Current Previous Year 2012 2011 Land Value $189,381 $157,818 Building Value $173,197 $174,288 Market Value $362,578 $332,106 Assessed Value $320,832 $311,488 Exemption Information: Current Previous Year 2012 2011 Homestead $25,000 $25,000 2nd Homestead $25,000 $25,000 Senior $0 $0 Veteran Disability $0 $0 Civilian Disability $0 $0 Widow(or) $0 $0 Disclaimer: Page 1 of 1 MIANII-DARE COUNTY OFFICE OF THE PROPERTY APPRAISER PROPERTY SEARCH SUMMARY REPORT Carlos Lopez-Centera Property Appraiser AeHat Photography 2012 Taxable Value Information: Current Previous Year 2012 2011 Exemption/raxable Exemption/Taxabie County $50,000/$270,832 $50,000/$261,488 School Board $25,000/$295,832 $25,000/$286,488 City $50,000/$270,832 $50,000/$261,486 Regional 7�700/$270,8321 $50,000/$261,488 Sale Information: Date Amount OR Book -Page Qualification Code 7/2012 $349,300 28213-3762 Deeds to or from financial Institutions 7/2001 $304,000 19800-2197 Sales which are qualified 12/1985 $102,500 12761-0347 1 Sales which are qualified 4/1981 1$100,0001 11143-2095 1 Sales which are qualified The Office of the Property Appraiser and Miami -Dade County are continually editing and updating the tax roll and GIS data to reflect the latest property information and GIS positional accuracy. No warranties, expressed or Implied, are provided for data and the positional or thematic accuracy of the data herein, its use, or its Interpretation. Although this website is periodically updated, this Information may not reflect the data currently on file at Miami -Dade County's systems of record. The Property Appraiser and Miami -Dade County assumes no liability either for any errors, omissions, or Inaccuracies In the Information provided regardless of the cause of such or for any decision made, action taken, or action not taken by the user in reliance upon any information provided herein. See Miami -Dade County full disclaimer and User Agreement at http://www.mlamidade.gov/Info/disclaimer.asp. Property Information Inquiries, comments, and suggestions email: pawebmail@miamidade.gov GIS inquiries, comments, and suggestions email: gis@miamidade.gov Generated on: Thu Apr 112013 http://gisweb.miamidade.gov/PropertySearch/printMap.htm 4/11/2013 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Miami Shores Village A� �� APPROVED BY DATE ZONI'N'G DEP r Florida Building Code Edition 2007 High -Velocity Hurricane Zone Uniform Pei mit Application+ornra� SuB. ECT 10 CG NIPiVNCE Q Fri All FEUERAL AND REGULATIONS r It No. Process No. ontractoes Name Job Address �� b / C ROOF CATEGORY lkLow Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tile ❑ Asphaltic ❑ Metal Panel/Shingles ❑ Wood Shingles/Shakes Shingles ❑ Prescriptive BUR -RAS 150 ROOF TYPE ❑ New Roof 'Reroofing ❑ Recovering ❑ Repair O Maintenance ROOF SYSTEM INFORMATION D Low Slope Roof Area (SF) 3 <_79 Steep Sloped Roof Area (SF) Total (SF) 3 �91 Section R (Roof R (Roof Plant Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly Identify dimensions of elevated pressure zones and location of parapets. FLORIDA BUILDING CODE — BUILDING 6 Florida Building Code Edition 2010 �. High Velocity Hurricane Zone Uniform Permit Application Form Section C Low Slopgd Roof System) Fill in Specific Roof Assembly Components Fastener Spacing for Anchor/Base Sheet and Identify Manufacturer Attachment (If a component is not used, identify as " 70 System Manufacturer: Field: . " oc @ Lap, # Rows " oc NOA No.' , � � Perimeter: " oc C? lap, #Rows` " @ 7` ' " oc Design. ss im RA , u,ations 0 ,' '"� Corner: oc @ Lap, # Rows L7o " cc Pmax1: ar _,_. 3x/�� 1 Number of Fasteners Per insulation Max. Design Pressur, ifio NOA Board System: �� Field: Perimeter Corner Deck: �•- 41 �> Illustrate Components Noted and Gaugeffhickness Details as Applicable: Woodbiockin Gutter. Ede Termination, Slope: � r � �° 9, 9 Stripping, Flashing, Continuous Cleat, Cant AnchorBaseSheet & No. ofPly(s)Strip, Base Flashing, Counter- Flashing, Coping, Etc. Anch�r ase Sheet Falpner ndie„r ndi ate: Mean Roof Height, Parapet Height, Com,. Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Insulation Base Layer: Spacing or Submit Manufacturers Details that ----------------- Comply with RAS 111 and Chapter 1 S. Base Insulation Size and ThicZhoMaterlal: Base Insulation Fastener/Bo Top Insulation Layer: Top insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Base Sheet Fastener/Bonding Ply Sheet(s) & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply:? . Top Ply Fastener/B dinoateri Surfacing: I FN Parapet Height Height MIAMICAM BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE (NOA) GAF Material Corporation 1361 Alps Road Wayne, NJ 07470 MIAMI-DADE COUNTY. FLORIDA METRO -DARE FLAOLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 331341563 (305) 375.2901 FAX (305) 375-2908 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by the BCCO and accepted by the Building Code and Product Review Committee to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code and the High Velocity Hurricane Zane of the Florida Building Code. DESCRIPTION: GAF RUBEROID® Modified Bitumen Roof System for Rood Decla. LABELING: Each unit shall bear a permanent label with the manufacturves name or logo, city, slate and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been tiled and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. if any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA No. 07-1203.01 and consists of pages 1 through 31. The submitted documentation was reviewed by Jorge L. Acebo. V-11", NOA No.: 09-OZ24.01 0. Expiration Date: 11/06!13 oe / Approval Date: 04/08/09 ('� Page 1 of 31 ROOFING SYSTEM APPROVAL ate o • Roofing Sub-Cateeorv: Modified Bitumen Material• SBS/APP Deck Wood Maximum Design Pressure -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 auc Leak Busteirm Matrixrm 307 Premium Asphalt Primer GAF Mineral Shields' Granules Leak BusterTM MatrixTm 305 Fibered Asphalt Emulsion Leak BusterTM MatrixTu 303 Premium Fibered Aluminum Roof Coating LeakBusterTM Matrikm 322 Elastomeric Roof Coating Ex"usterTM MatrixIm 306 LeakBusterTm MatrixTM 204 Wet(D y Roof Cement GAFGLASP #75 Base Sheet GAFGLAS®#80 ULTIMATM Base Sheet GAFGLAS® Flex Plym 6 GAFGLAS® Ply 4 GAFGLAS® Mineral Surfaced Cap Sheet ^rPRGVF.DI Test Product Dimensions Specification Descrintian 5, 55 gallons ASTM D41 Asphalt concrete primer used to promote adhesion of asphalt in built-up roofing. 60 lb. Bags 100 lb. bags 5 gallons 1, 5 gallons 55 gallons 55 gallons 1, 5 gallons 39.37"(1 meter) Wide ASTM D1863 Granules for surfacing of exposed asphalt, cold process cement or emulsion. GAF Mineral Shield's Granules shall be used for flashing applications only. ASTM D1227 Surface coating for smooth surfaced roofs. ASTM D 2824 Fibered aluminum coating Elastomeric roof coating Asphalt emulsion fibered. ASTM D3019 Refined asphalt blended with a mineral ASTM D3409 stabilizer and fibers. Permits adhesion to ASTM D4586 wet and dry surfaces. ASTM D3409 with asphalt coating. ASTM D4601 Type H Asphalt impregnated and coated Wide glass mat base sheet 39.37" (1 meter) ASTM D4601 Type II Asphalt impregnated and coated, Wide . fiberglass base sheet 39.37' (1 meter) ASTM D2178 Type VI•asphalt impregnated glass felt Wide with asphalt coating. 39.37' (i meter) ASTM D2178 Type IV asphalt impregnated glass felt Wide with asphalt coating. 39;37' (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet Wide surfaced with mineral granules. NOA No.: 09-0224.41 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 2 of 31 RUBEROV Modified 39.3T' (I meter) ASTM D4601, Premium glass fiber reinforced SBS - Base Sheet Wide 'Type 11, UL Type modified base sheet G2 BUR RUBER00 SBS 1 meter (39.37") ASTM D6164 Non -Woven Polyester mat coated with Heat WeldTM 25 wide polymer -modified asphalt and smooth surfaced. MOA No» 09-0224.01 M E Expiration Date: II/Ob/13 Approval Date: 09,!08/09 Page 3 of 31 Test Product Prod u i e . io Specification Description GAFGLAS EnawQpTM 39.37" (1 meter) ASTM D3909 Asphalt coated, glass fiber mat cap sheet Mineral Surfaced Cap Sheet Wide surfaced with mineral granules with factory applied layer of TOPCOAT GAFGLAS* EnergyCapTM 39.37" (1 meter) ASTM D3909 EnergyCoteTM. Asphalt coated, glass fiber mat cap sheet BUR Mineral Surface Cap wide EnergystarTm surfaced with mineral granules with Sheet Title 24 factory applied EnergyCoteTM GAFGLAS`° 39.37" (1 meter) Compliant ASTM D3672 Fiberglass base sheet coaxed on both sides STRATAVENT Wide ASTM D4897 with asphalt, Surfaced on the bottom side Eliminatoim Perforated with mineral granules embedded in asphaltic coating with factory perforations. GAFGLAS'* Flashing various Asphalt coated glass fiber mat flashing sheet available in three sizes. GAFGLAS* 39.3T' (1 meter) ASTM D3672 Fiberglass base sheet coaxed on both sides STRATAVENIO Wide ASTM D4897 with asphalt. Surfaced on the bottom side EliminatorTM Perforated with mineral granules embedded in Nailable asphaltic coating. RUBERO& SBS 1 meter (39.3 T') ASTM D6164 Non -Woven Polyester mat coated with Heat-WeldTM Smooth wide polymer -modified asphalt and smooth RUBERO& SBS 1 meter (39.37") ASTM D6164 surfaced. Non -Woven Polyester mat coated with Heat Weldrm Granule wide polymer modified asphalt and surfaced with mineral granules. Roof MatchTM 107 sq. ft. ASTM D6222 Non -woven polyester mat coated with SBS Mop Granule (9.9 m2) ASTM D5147 polymer modified asphalt and surfaced with colored mineral granules. RUBEROO SBS 1 meter (39.37') ASTM D6164 Non -Woven Polyester mat coated with Heat-WeldTM 170 FR wide fire retardant polymer modified asphalt RUBEROIDP SBS 1 meter (39.37") ASTM D6164 and surfaced with mineral granules. Non -Woven Polyester mat coated with Heat-WeldTM PLUS wide polymer modified asphalt and surfaced RUBER00 SBS 1 meter (39.37") ASTM D6164 with mineral granules. Non -Woven Polyester mat coated with Heat -Weld'" " PLUS FR wide fore retardant polymer modified asphalt and surfaced with mineral granules. RUBEROW*Ener:,gyCap 1 meter (3937') ASTM D6164 A fiberglass mat reinforced, SBS modified SBS Heat-WeldTM PLUS FR wide bitumen cap membrane. RUBEROV Modified 39.3T' (I meter) ASTM D4601, Premium glass fiber reinforced SBS - Base Sheet Wide 'Type 11, UL Type modified base sheet G2 BUR RUBER00 SBS 1 meter (39.37") ASTM D6164 Non -Woven Polyester mat coated with Heat WeldTM 25 wide polymer -modified asphalt and smooth surfaced. MOA No» 09-0224.01 M E Expiration Date: II/Ob/13 Approval Date: 09,!08/09 Page 3 of 31 NOA No.: 09-0224.01 Expiration Date: 11/06/13 Approval Date: 04/080 Page 4 of 31 Test Product P� bectatn 'onor RUBEROIDMop Granule 39.3T' (I meter) ASTM D6222 Non -woven polyester mat coated with Wide ASTM D5147 polymer modified asphalt and surfaced RUBEROV MOP Smooth 1 sq. roll ASTM D6298 with mineral granules. Non -woven polyester mat coated with 87 lbs. ASTM D5147 polymer -modified asphalt and smooth RUBEROID� MOP PLUS 39.37" (1 meter) ASTM D6164 surfaced. Non woven polyester mat coated with Wide ASTM D5147 polymer modified asphalt and surfaced RUBEROV MOP 170FR 39.37" (1 meter) ASTM D6164 with mineral granules. Non -Woven polyester mat coated with fire Wide ASTM D5147 retardant polymer modified asphalt and RUBEROID* MOP FR 39.37" (1 meter) ASTM D6164 surfaced with mineral granules. Non -Woven polyester mat coated with fire Wide ASTM D5147 retardant polymer modified asphalt and RUBEROV TORCH 39.37" (1 meter) ASTM D6222 surfaced with mineral granules. Heavy duty, polyester reinforced, asphalt Smooth Wide ASTM D5147 modified bitumen membrane, smooth RUBEROID® TORCH 3937" (1 meter) ASTM D6222 surface. Heavy duty, polyester reinforced, asphalt Granule Wide ASTM D5147 modified bitumen membrane, granule RUBEROID®EnergyCap 1 meter (39.37") ASTM D6222 surface. A fiberglass mat reinforced, SBS modified Torch Granule FR wide ASTM D5147 bitumen cap membrane. Roof MatchTm 107 sq. ft. ASTM D6222 Non -woven polyester mat coated with APP Torch Granule (9.9 m2) ASTM D5147 polymer modified asphalt and surfaced with colored mineral granules. RUBEROe TORCH 39.3T'(1 meter) ASTM D6222 Heavy duty, polyester reinforced, asphalt PLUS Wide ASTM D5147 modified bitumen membrane, granule RUBEROV TORCH FR 39.37" (1 meter) ASTM D6222 surface Heavy duty, polyester reinforced, coated Wide ASTM D5147 with fire retardant asphalt modified RUBEROV 170FR 39.37" (1 meter) ASTM D6222 bitumen membrane, granule surface. Heavy duty, polyester reinforced, coated TORCH Wide ASTM D5147 with fire retardant asphalt modified RUBER010* EnergyCap I meter (39.3T') ASTM D6163 bitumen membrane, granule surface. A fiberglass mat reinforced, SBS modified SBS Heat Weld Plus FR wide ASTM D5147 bitumen cap membrane. RUBEROW020 39.37" (1 meter) ASTM D6163 SBS modified asphalt base sheet reinforce RUBER0030 Wide ASTM D5147 with a glass fiber mat. 39.37" (1 meter) ASTM D6163 Non woven fiberglass mat coated with Wide ASTM D5147 polymer modified asphalt and surfaced with mineral granules. NOA No.: 09-0224.01 Expiration Date: 11/06/13 Approval Date: 04/080 Page 4 of 31 Pr RUBEROID D-inue—usions Test Stec cati n Product Dwrltition 30 FR 39.37" (1 meter) ASTM D6298 Non woven fiberglass mat coated with fire Membrane Wide ASTM D5147 retardant, polymer modified asphalt and RUBERO1Ds'EnerRyCap SBS 30 FR I meter (39.37") ASTM D6163 surfaced with mineral granules, A fiberglass mat reinforced, SBS modified VersaShieid" wide ASTM -D226 bitumen cap membrane. RUBEROIDP ULTRACLAD� SBS 39-37"(1 meter) ASTM D6163 Woven fiberglass mat coated with MB Wide ASTM D5l 47 Polymer modified asphalt surfaced with RUBEROH? Dual FR 39.37" (1 meter) ASTM D6164 alumess steel foil. Non -woven polyestercopper or andfiberglass mat Leak BusterTm MatrixTu Wide ASTM DS 147 coated with file retardant, polymer - 531 WeatherCoteTM Elastomeric Flashing Gracie modified asphalt and surfaced with Vent Stacks 5 gallons ASTM D3019 mineral granules. (metal and plastic) TAS 100(A) One-way valve vent used to relieve built - Leak Busteerm MatrixTM 102 SBS Adhesive Label 5 gallons ASTM D1929 up pressure within the roof system. GAF ASTM D635 Vent Stacks are available in metal or GAF Built-UpRoofing g Asphalt 100 Ib. cartons, ASTM D312, Fustic. interply mopping and surfacing asphalt bulk Types I, 11, 111 RUBEROV MOD As Asphalt F Asphalt L & Asphalt P 60 lb. kegs l� and N SEBS modified asphalt TOPCOAT® Surface Seal SB 5 gallons Surface coating for smooth surfaced and mineral surfaced roofs. LEAK BUSTERTM MatrixTm 715 MB 5 gallons ASTM D3412 Surface coaxing for smooth surfaced and EIastomeric Roofing ASTM D21 ASTM D1475 mineral surfaced roofs, Membrane ASTM E1644 EnergyC'oteTm Coating 2,5 gallons � g ASTM D6083 Highly reflective elastomeric coating . VersaShieid" 350 sq. ft roll ASTM -D226 Non -Asphaltic Fiberglass -Based TOPCOATa' FireShield� 5, SS gallons 4869 Type 1, II ASTM D412 Underlayment Elastomeric roofing membrane MB ASTM D21 ASTM 1475 Leak BusterTm MatrixTu 5 gallons ASTM E1644 Surface coating for smooth surfaced and 531 WeatherCoteTM Elastomeric Flashing Gracie mineral surfaced roofs. LeakBusterTM MatrixTM 201 Premium SBS Flashing 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt Adhesive— Flashing Grade. Leak Busteerm MatrixTM 102 SBS Adhesive Label 5 gallons ASTM D3019 Cold Applied Modified SEBS Asphalt Adhesive. NOA No.: 09-0224.01 Expiration Date: 11106113 ' Approval Date: 04108109 Page 5 of 31 NOA No.: 094224.01 Expiration Date: 11/06113 Approval Date: 04/05/09 Page 6 of 31 Test Product Product Dimensions Speeftedion DescriDtIon Leak BusterTm Matrberm 202 5 gallons ASTM D4586 Cold Applied Modified SEBS Asphalt SBS Flashing Cement Label Adhesive — Flashing Grade. Leak Busterrm MatrixTm 5 gallons ASTM D4586 Standard Plastic Asphalt Roofing Cement 203 Plastic Roof Cement Label Leak BusterTM Matrix:m 5 gallons ASTM D3019 Cold Applied Asphalt Adhesive. 103 Cold Process Adhesive Label LeakBusterTM MatrixTm 304 5 gallons ASTM D2824, Non-fibered. Aluminum pigmented, Non-FIbered Aluminum Type l asphalt roof coating. Roof Leak Bustefrm MatrixTM 5 gallons ASTM D412 Surface coating for smooth surfaced and 602 MB Xtra Elastomeric ASTM B 117 mineral surfaced roofs. Roofing Membrane ASTM C794 ASTM 021 FTMS141.6271 ASTM D21% ASTM D1475 ASTM B1644 TOPCOAT® MB Plus 5, 55 gallons ASTM D412, Water-based, low VOC, sprayable ASTM D21, polymeric liquid, which cures to form a ASTM D1475 seamless rubber membrane. ASTM El 644 NOA No.: 094224.01 Expiration Date: 11/06113 Approval Date: 04/05/09 Page 6 of 31 APPROVED INSULATIONS: Table 2 Product Name Product Description Manufacturer (With Current NOA) EnergyGuardTM Fiberboard Fiberboard insulation GAF Materials Corp. EnergyGuardTM Permalite Perlite insulation board GAF Materials Corp. EnergyGuardTM Strip Cut perlite board GAF Materials Corp. EnergyGuardTM Recover Board Perlite recover board GAF Materials Corp. EnergyGuardTM Tapered Edge Strip Tapered perlite board GAF Materials Corp. EnergyGuardTM Polylso Polyisocyanurate foam insulation GAF Materials Corp. EnergyGuardTM RA, RN Polyisocyanumte foam insulation GAF Materials Corp. EnergyGuaffm Composite, RA Polyisocyanuratelwood fiberboard or GAF Materials Corp. perlite composite DensDeckv Water resistant gypsum board G -P Gypsum Corp. DensDeck Prime' Water resistant gypsum board G -P Gypsum Corp. DensDeck DumGuardTm Water resistant gypsum board G -P Gypsum Corp StructodeV Wood fiber insulation board Knight Celotex Structode,0 TD Flame Resistant High Density Wood Knight-Celotex Fiber board. Securock7m Fiber reinforced roof board USG Corporation APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) I. Drill-TecTm #12 Standard, Insulation fastener and Various GAF Materials Corp. # 14 and # 15 extra Heavy Base Play fastener for Duty Fastener, Heavy Duty steel, wood & concrete Roofing Fastener decks. 2. Drill-TecTM ASAP Pre -assembled Drill-Te6m Various GAF Materials Corp. Fasteners and metal and plastic plates. 3. Drill-TecTM CR Base Base sheet fastening Various GAF Materials Corp. Sheet Fastener and Plate assembly. 4. Drill-TecTM Galvalume Round Galvalume stress 3" and 3 %a" GAF Materials Corp. Plates plates. 5. Drill-TecTM Polypropylene Round polypropylene 3" and 3'/" GAF Materials Corp: Plates stress plates. 6. Drill-TecTM AccuTrac Square Galvalume coated 3" Square OMG Plate steel plate. NOA No.: 09-0224.01 Expiration Date: 11/06/13 Approval Date: 04/08/09 Page 7 of 31 EVIDENCE SUBWMD: TestAn Test Identifier DMSdg#gR Date Factory Mutual Research Corp, 3029832 4470 - TAS 114 05111/07 3010215 4470 - TAS 114 03/01/01 3001276 4470 - TAS 114 01/28/99 1 B9A8.AM 4470 -TAS 114 09/04/97 3D4Q2.AM 4470 - TAS 114 04/30/97 Underwriters Laboratories ODIA8.AM TGFU.RI9254 4470 - TAS 114 , UL 790 04/01/98 10127/06 Trinity Engineering 4483.04 97-1 TAS 114 06/06/97 PRI Asphalt Technologies, Inc. GAF -020-02-01 ASTM D 249 02/01/02 ASTM D 4977 IRT-ARCON Inc. 02-005 TAS 114 03/01/02 02-014 TAS 114 04/08/Q2 TrinityI ERD 01-039 TAS 114 03/0.1102 . G6850.08.08 ASTM D6164 08/29/08 G6850.08.08 ASTM D6163 08/01/08 66850.10.08 ASTM D6222 10/06108 G6850.11.08 ASTM D6222 11/05/08 NOA No.: 09-0224.01 Cm Expiration Date: 11/06/13 Approval Date: 04!08/09 Page 9 of ..31 Membrane Type: APP/SBS Heat Weld Deck Type is Wood, Non -insulated Deck Description: 19 /32" or greater plywood or wood plank decks System Type E(2): Base sheet mechanically fastened. All General and System Limitations shall apply. Fire Barrier: FireOutTM Fire Barrier Coating, VersaShield®Non As haltic Fib (optional} Underlayment or SecurockTM. p erglass-Based Base sheet: GAFGLASO' #80 ULTIMATm Base Sheet, STRATAVo4r Eliminatorrm Na"able, RUBEROID'a Modified Base Sheet, RUBEROV MOP Smooth, RUBEROID'o 20, RUBEROV SBS Heat WeldrM Smooth or RUBEROID® SBS Heat -Weld 25 base sheet mechanically fastened to deck as described below;. Fasteaing options: GAFGLAS'a PIy 4, GAFGLASO FIex plyTM 6, GAFGLAS® #75 Base Sheet or any Of above Base sheets attached to deck with approved annular ring shank nails and o.c. in the field. tin caps at a fastener spacing of 9" O.C. at the lap staggered and in two rows 12" {Maximum Design Pressure --45 psf, See General Li n&4 on #7j GAFGLASe Ply 4, GAFGLAS Flex P1yTM 6, GAFGLAS" #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # IS Screws and 3" Drill-TecTm steel plate or Drill-TecTM AccuTrac Plates, 12" O.C. in 3 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. tmurn Design Pressure-4Spsf, See General Limitatlon #7j GAFGLAS' Flex PIyTu 6, GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" O.C. at the 4" lap staggered and in two rows 9,10.0. in the field. (Madmum Design Pressure 52.5 psf, See General Lbnkadon #7) GAFGLAS® #80 ULTMA"RUBEROMP20, RUBEROMOMop Smooth, base sheet attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the V Iap staggered and in two rows 9" O.G. in the field. (Maximum Design Pressure-60psf, See General Limitation #7j GAFGLAS® #75 Base Sheet or any of above Base sheets attached to deck with Drill-TMTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill-TWTm AccuTrac plates, l2" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o.c, in the field of the sheet. (Maximum Design Pressure -f0 psf, See General Limitation #7) .. ... Any of above Base sheets attached to deck approved annular ring shank nails and ` 3" inverted Drill-TecTM insulation plates at a fastener spacing of 9" o.c, at the 4" lap staggered in two rows 9" in the field. (Maximum Design Pressure -60 psf, See General Limitation #7} NOA Na: 09-0224.01 cum Expiration Date: 11/016113 Approval Date: 04!08/09 Page 29 of 31 GAFGLAS* #75 Base Sheet or any of above Base sheets attached to deck with Drill-TecTM #12 standard, #14 or # 15 Screws and 3" Drill-TecTM steel plate or Drill TecTM AccuTrac Plates, 8" o.c. in 4 rows. One row is in the 2" side lap. The other rows are equally spaced approximately 9" o c. in the field of the shoot. (Maximum Design Pressure —7S psf, See General Limitation #7) Ply Sheet: (Optional except over RUBEROe Modified Base Sheet, RUBEROID11 MOP Smooth, RUBEROEU* 20, RUBEROID® SBS Heat WeldTM Smooth or RUBEROe SBS Heat-WeIdTM) One or more plies GAFGLAS® PLY 4 or GAFGLAe Flex P1y7M 6 sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20.40 lbsJsq: or RUBEROID®Torch Smooth torch applied according to manufacturer's application instructions. Membrane: One ply of RUBEROV Torch Smooth, RUBEROID`eTorch Granule, Roof MatchTM APA Torch Granule, RUBEROID® Ener&CapTM Torch Granule FF., RUBEROIDp Torch Plus Granule, RUBEROID® EnergyCapTM Torch Plus FR, or RUBEROVTorch FR torch applied according to manufactu rees application instructions. Or One or more plies of RUBEROV SBS Heat WeldTM PLUS, RUBEROO SBS Heat-WeldTM PLUS FR, RUBEROV SBS Heat-WeldTM 170 FR, RUBEROiD® EnergyCapTM SBS Heat WeldTM Plus FR, RUBEROV SBS Heat-WeldTM, RUBEROWD SBS Heat WeldTM Smooth, RUBEROIDD ULTRACLADO SBS and RUBEROM0 SBS Heat-Weld7m 25 applied according to manufacturer's application instructions. Surfacing: (Optional, required if RUBEROID`e MOP Smooth or RUBEROID® 20 is top membrane) Install one of the following: I. Gravel or slag applied at 400 lbsJsq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbsJsq. or applied in a flood coat of Leak BusW71w MatrixTM 103 Cold Process Adhesive applied at a rate of 3 gaL/sq. 2. GAFGLAS® Mineral Surfaced Cap Sheet, GAFGLASz Energy Cap Mineral Surfaced Capsheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq. 3. Leak BusterTM MatrixTM 303 Premium Fibered Aluminum Roof Coating, at 1.5 gal./sq. 4. Leak BuswTM MatrixTM 715, Leak BusterTM MatrixTM 322, TOPCOAT MB+, TOPCOAT® Fireshield Elastomeric Roofing Membrane, applied at I to 1.5 gaUsq. 5. Leak BusterTM MatrixTM 602 MB Xtra Elastomeric Roofing Membrane, EnergyCotcP roof coating applied at I to 1.5 ,galJsq. 6. TOPCOAT Surface Seal, TOPCOAT Fireshield® SB Solvent based Elastomeric Roofing Membrane applied at Ito 1.5 galJsq 7. Advance Green Technologies Photovoltaic Laminate solar energy collector auxiliary roof equipment installed in compliance with manufacturer's specifications and applicable Building Codes. Maximum Design Pressure: See Fastening Above NOA No.: 09-0224.01. cm Expiration Date:11106113' Approval Date: 04/08/09 Page 30 of 31 WOOD DECK SYSTEM LDUTATIONS: I A slip sheet is required with Ply 4 and Flex PIy 16 when used as a mechanically fastened base or anchor sheet. 2. Minimum %a" Dens Deck or le Type X gypsum board is acceptable to be installed directly over the wood deck. GENERAL LmTATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" n'bbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A b" break shall be placed every 17 in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 pstA 5. Fasten spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field- tested, are below 275 Ibfinsulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchorlbase sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas.. , Fastener densities shall be increased for both insulation and lase sheet as calculated in compliance with':-.':-: Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation 09 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 1 I 1 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced • - ` , fastening at enhanced pressure zones (i.e. perimeters, extended corners and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9B-72 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 09-0224.01 Expiration Date: 11/0b/13 Approval Date: 04/08/04 Page 31 of 31 TGFU.R1306 - Roofing Systems Page 3 of 3, . Base Sheet —One or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply@ #75 Base Sheet" or Type G3 "GAFGLAS@ Mineral.'..:, Surfaced Cap Sheet* or Irri-Piy@ Mineral Surfaced Cap Sheet" hot mopped or mechanically fastened. Ply Sheet (Optional): — One or more plies Type G1, hot mopped In place, Membrane: — One ply "Ruberoid@ Torch Smooth" or "Ruberoid@ Mop Smooth" or "Ruberoid@ Mop Smooth 1.5" or "Ruberoid@ Mop Smooth Plus" or "Ruberold@ Dual Smooth." Membrane: — One ply "Ruberoid@ Mop FR" or "Ruberoid@ EnergyCapTM Mop FR." 55. Deck: NC Incline: 1 Irtsuia-. ,,, ,nan: = Polytsocyanurate, wood fiber, perfite, glass fiber, any thickness, hot mopped or mechanically fastened. Base — On S e or more plies Type G2 "GAFGLAS® #75 Base Sheet", or "Tri -Pty@ #75 Base Sheet", mechanically fastened. • — One or more plies "Ruberoid® 20" or "Ruberoid® 20 Kr or "Ruberoid@ Dual Smooth" hot mopped in place. embrane. One ply "Ruberoid@ SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat Weld 170 FR" heat welded In place. $6. Deck$ C-15/32 / Incline: 1/2 Two or more plies Type G2 "GAFGLAS@ #75 Base Sheet" or "Tri -Ply® #75 Base Sheet" mechanically fastened. One ply "Ruberoid® SBS Heat Weld Plus FR" or "Ruberoid@ SBS Heat Weld 170 FR" heat welded in place. hq://database.ui-com/c,gi-bWXYV/template/LISEXT/ 1 FRAME/showpage.html?name=T... 8/28/2012 LOD SECTION R4402.13 HIGH VELOCITY HURRICANE ZONES – REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS R4402.13.1 Scope. As it pertains to the section, it is the responsibility of roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of the section. The provisions of Section R4402 govem the minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the owner ant the contractor. The owner's initial in the designated space indicates that the item has been explained. 1. ` Aesthetics -Workmanship: the workmanship provisions of Section R4402 are for the purpose of providing that the roof system meets the wind resistance and water instruction performance standards. Aesthetics (appearance) are not a consideration with respect to workmanship provisions. Aesthetic issues such as color or architectural appearance, that are not part of a zoning code, should be addressed as part of the agreement between the owner and the contractor. 2._Renailing wood decks: When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Section R4403. (The roof deck is usually concealed prior to removing the existing roof system). 3. IL —Common roofs: Common roofs are those which have no visible delineation between neighboring units (i.e., townhouses, condominiums, etc.) In buildings with common roofs, the roofing contractor and/or owner should notify the occupants of adjacent units of roofing to be performed. 4. E —S Exposed Ceiling: Exposed, open beam ceilings are where the underside of the roof decking can be viewed from below. The owner may wish to maintain the architectural appearance; therefore, roofing nail penetration of the underside of the decking may not be acceptable. This provides the option of maintaining the appearance. 5. Ponding water: The current roof system and/or deck of the building may not drain well and may cause water to pond (accumulate) in low-lying areas of the roof. Pounding can be an indication of structural distress and may require the review of a professional structural engineer. Pounding may shorten the life expectancy and performance of the new roofing system. Pounding conditions may not be evident until the original roofing system is removed. Pounding conditions should be corrected. 6. t Overflow scuppers (wall outlets): It is required that rainwater flows off so that the roof is not overloaded from a buildup of water. Perimeter/edge wall or other roof extension may block this discharge if overflow scuppers (wall outlets) are not provided. It may be necessary to install overflow scuppers in accordance with the requirements of Sections R4402, R4403 and R4413. 7. I- Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of the structure assembly (the building itself). The existing amount of attic ventilation shall not be reduced. It -be beneficial to consider additional venting which can result in extending the seyce life of he P;�= gignafure Date Contract ' n D e Revised on 7/9/2009 LD